This document provides details for an upcoming Multiple Award Construction Contract opportunity in Italy. The scope of work involves design-build construction services for projects across multiple trades at Aviano Air Base, primarily including grading, utilities, painting, roofing, building renovation, HVAC, fire suppression, fuel systems, electrical work, and site development. The base period of performance is one year with four optional one-year extensions. The minimum guaranteed award amount is $2,500 Euro and maximum combined value of all awards is estimated at $96 million USD. The minimum task order value is $2,500 and maximum is $7 million. Interested parties should submit any comments on the draft solicitation documents by April 19, 2019 to the 31st Contracting Squadron at Aviano Air Base. Award is anticipated in May 2019.
ANNEX S-STRUCTURAL PART 8
View the file
Other files for this federal contract opportunity
Show all 50
Multiple Award Construction Contract (MACC) Italy has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RENOVATE/EXPAND FAC. 939 ANNEX S2.1 ASHE 18-1025
FINAL (100% design) DESIGN ANALYSIS Pag.11 di 67
CAPITOLO 2.6 COMBINAZIONI DI CARICO
Nell’analisi sismica della struttura sono stati utilizzati i seguenti carichi elementari:
− DEAD: carichi permanenti strutturali delle strutture modellate (calcolate automaticamente dal programma)
− G1: altri carichi permanenti strutturali
− G2: carichi permanenti non strutturali
− QS: carico neve
− RSLVX, RSLVY: carico sismico con spettro di risposta allo SLV
− QKX, QKX-Y, QKY, QKY-X: carico sismico da analisi statica equivalente
Tutte le altre tipologie di carico unitario definite nel modello d’analisi non sono state utilizzate.
Seguono le tabelle delle combinazioni di carico sismiche implementate nel codice di calcolo, dove QKE: combinazioni valide per le verifiche allo SLV in condizioni sismiche:
TABLE: Combination Definitions
ComboName ComboType CaseName ScaleFactor
Text Text Text Unitless
COMBO_DEAD Linear Add DEAD 1
COMBO_DEAD G1 1
QKEX Linear Add COMBO_DEAD 1
QKEX G2 1
QKEX Qe 0.6
QKEX RSLVX 1
QKEX RSLVY 0.3
QKEY Linear Add COMBO_DEAD 1
QKEY G2 1
QKEY Qe 0.6
QKEY RSLVX 0.3
QKEY RSLVY 1
Per le verifiche delle strutture di fondazioni nei confronti delle azioni sismiche sono state inoltre utilizzate le combinazioni di carico riportate nella seguente tabella.
Case LoadName LoadSF
Text Text Unitless
QKE1-NL COMBO_DEAD 1
G2 1
QKX 1
QKY 0.3
QKX-Y 1
QKY-X 0.3
QKE2-NL COMBO_DEAD 1
G2 1
QKX -1
QKY 0.3
QKX-Y -1
QKY-X 0.3
FINAL (100% design) DESIGN ANALYSIS Pag.12 di 67
Case LoadName LoadSF
Text Text Unitless
QKE3-NL COMBO_DEAD 1
G2 1
QKX 1
QKY -0.3
QKX-Y 1
QKY-X -0.3
QKE4-NL COMBO_DEAD 1
G2 1
QKX -1
QKY -0.3
QKX-Y -1
QKY-X -0.3
QKE5-NL COMBO_DEAD 1
G2 1
QKX 0.3
QKY 1
QKX-Y 0.3
QKY-X 1
QKE6-NL COMBO_DEAD 1
G2 1
QKX 0.3
QKY -1
QKX-Y 0.3
QKY-X -1
QKE7-NL COMBO_DEAD 1
G2 1
QKX -0.3
QKY 1
QKX-Y -0.3
QKY-X 1
QKE8-NL COMBO_DEAD 1
G2
QKX -0.3
QKY -1
QKX-Y -0.3
QKY-X -1
FINAL (100% design) DESIGN ANALYSIS Pag.13 di 67
CAPITOLO 2.8 CRITERI DI MODELLAZIONE
Al fine della valutazione sismica dell’edificio, considerato costituito da due corpi di fabbrica indipendenti interamente realizzati in c.a., viene utilizzata un’analisi dinamica lineare (spettro di risposta).
Segue una sintetica descrizione dei modelli di calcolo utilizzati.
I modelli numerici per la valutazione della risposta dinamica delle strutture sono stati ottenuti modellando tutti gli elementi resistenti principali: travi, pilastri e setti. Le tamponature, invece, sono inserite solo come massa. Tali elementi sono stati modellati ricorrendo ad elementi monodimensionali (frame) per quanto riguarda le travi, elementi bidimensinali (shell) per quanto riguarda i setti. Per semplicità e senza perdere di precisione nell’analisi, è stata trascurata la pendenza dela copertura modellando i solai come orizzontali; questi sono stati inseriti come elementi nulli, al solo scopo di ripartizione dei carichi verticali, e sono stati introdotti dei diaframmi di piano per modellare il comportamento irrigidente degli stessi: ipotesi di piano rigido.
Per l’analisi delle strutture in elevazione si è trascurata l’interazione terreno-struttura e i pilastri sono stati incastrati al piede. Per la valutazione delle strutture di fondazione sono stati poi sviluppati dei modelli specifici in cui l’interazione terreno-struttura è modellata con molle alla Winkler reagenti solo a compressione; la valutazione dell’azione sismica è condotta con un’analisi statica equivalente.
Le masse sono state dedotte automaticamente dai carichi (secondo quanto richiesto nel punto 3.2.4 delle NTC18) dagli elementi e dalle masse inserite manualmente. Il codice di calcolo, in automatico, inserisce le masse concentrate sui nodi
(distribuzione lumped). Le masse risiedenti sui diaframmi sono state condensate nel baricentro delle masse, detto nodo master.
Seguono alcune immagini dei modelli di calcolo realizzati.
FINAL (100% design) DESIGN ANALYSIS Pag.14 di 67
Blocco A – Stato di Fatto
Modello senza fondazioni
FINAL (100% design) DESIGN ANALYSIS Pag.15 di 67
Modello con fondazioni
FINAL (100% design) DESIGN ANALYSIS Pag.16 di 67
Analisi modale (modello senza fondazioni)
5^ forma modale, T = 0.130 s, massa partecipante in UX = 14%, UY = 12%, RZ = 70%
9^ forma modale, T = 0.051 s, massa partecipante in UX = 5%, UY = 44%, RZ = 4%
FINAL (100% design) DESIGN ANALYSIS Pag.17 di 67
10^ forma modale, T = 0.034s, massa partecipante in UX = 66%, UY = 2%, RZ = 20%
Blocco B – stato di fatto
FINAL (100% design) DESIGN ANALYSIS Pag.18 di 67
Analisi modale
1^ forma modale, T = 0.217 s, massa partecipante in UX = 100%, UY = 0%, RZ = 0%
2^ forma modale, T = 0.171 s, massa partecipante in UX = 0%, UY = 66%, RZ = 37%
FINAL (100% design) DESIGN ANALYSIS Pag.19 di 67
4^ forma modale, T = 0.152 s, massa partecipante in UX = 0%, UY = 33%, RZ = 63%
FINAL (100% design) DESIGN ANALYSIS Pag.20 di 67
Blocco B – stato di progetto
Modello senza fondazioni
Modello con fondazioni
FINAL (100% design) DESIGN ANALYSIS Pag.21 di 67
Analisi modale (modello senza fondazioni)
2^ forma modale, T = 0.146 s, massa partecipante in UX = 0%, UY = 91%, RZ = 10%
4^ forma modale, T = 0.139 s, massa partecipante in UX = 99%, UY = 0%, RZ = 0%
FINAL (100% design) DESIGN ANALYSIS Pag.22 di 67
5^ forma modale, T = 0.107 s, massa partecipante in UX = 0%, UY = 8%, RZ = 89%
FINAL (100% design) DESIGN ANALYSIS Pag.23 di 67
Nei modelli delle sole strutture in elevazione il carico sismico, come accennato precedentemente, è stato definito attraverso due analisi con spettro di risposta (RSLVX, RSLVY) definite come di seguito:
TABLE: Case - Response Spectrum 1 - General
Case ModalCombo PerRigid DirCombo DampingType ConstDamp NumOverride
Text Text Text Text Text Unitless Unitless
RSLVX CQC SRSS SRSS Constant 0.05 0
RSLVY CQC SRSS SRSS Constant 0.05 0
TABLE: Case - Response Spectrum 2 - Load Assignments
Case LoadType LoadName CoordSys Function Angle TransAccSF
Text Text Text Text Text Degrees m/sec2
RSLVX Acceleration U1 GLOBAL SLV_AVIANO-q-1.5 0 9.81
RSLVY Acceleration U2 GLOBAL SLV_AVIANO-q-1.5 0 9.81
Nei modelli con le fondazioni, le forze orizzontali sono calcolate dal programma con un’analisi statica equivalente. Il coefficiente da applicare alle masse è stato valutato in modo da eguagliare il taglio totale fornito dall’analisi con spettro di risposta dei modelli con le sole elevazioni.
Blocco A
LoadPat Dir PercentEcc EccOverride UserZ C K
Text Text Unitless Yes/No Yes/No Unitless Unitless
QKX X 0.05 No No 0.304 1
QKY Y 0.05 No No 0.338 1
QKX-Y Y 0.05 No No 0.130 1
QKY-X X 0.05 No No 0.130 1
Blocco B
LoadPat Dir PercentEcc EccOverride UserZ C K
Text Text Unitless Yes/No Yes/No Unitless Unitless
QKX X 0.05 No No 0.562 1
QKY Y 0.05 No No 0.528 1
QKX-Y Y 0.05 No No 0.002 1
QKY-X Y 0.05 No No 0.002 1
FINAL (100% design) DESIGN ANALYSIS Pag.24 di 67
CAPITOLO 2.9 RISULTATI DELLE ANALISI
Blocco A
Reazioni alla base
Si riportano di seguito le azioni globali alla base della struttura per le diverse condizioni e combinazioni di carico.
TABLE: Base Reactions
OutputCase CaseType StepType GlobalFX GlobalFY GlobalFZ
Text Text Text KN KN KN
DEAD LinStatic 0 0 2089
G1 LinStatic 0 0 1200
G2 LinStatic 0 0 711
Qh LinStatic 0 0 222
QS LinStatic 0 0 533
RSLVX LinRespSpec Max 1352 581 44
RSLVY LinRespSpec Max 581 1506 96
QKX LinStatic -1948 0 0
QKY LinStatic 0 -2157 0
STR1 Combination 0 0 5199
STR2 Combination 0 0 5199
STR3 Combination 0 0 5999
STR4 Combination 0 0 5599
QKEX Combination Max 1527 1033 4072
QKEX Combination Min -1527 -1033 3926
QKEY Combination Max 987 1681 4108
QKEY Combination Min -987 -1681 3890
FINAL (100% design) DESIGN ANALYSIS Pag.25 di 67
Caratteristiche di sollecitazione
Si riporta l’inviluppo dei momenti flettenti in condizioni sismiche.
FINAL (100% design) DESIGN ANALYSIS Pag.26 di 67
Blocco B – Stato di fatto
Reazioni alla base
Si riportano di seguito le azioni globali alla base della struttura per le diverse condizioni e combinazioni di carico.
TABLE: Base Reactions
OutputCase CaseType StepType GlobalFX GlobalFY GlobalFZ
Text Text Text KN KN KN
DEAD LinStatic 0 0 339
G1 LinStatic 0 0 235
G2 LinStatic 0 0 164
Qh LinStatic 0 0 48
QS LinStatic 0 0 114
RSLVX LinRespSpec Max 540 0 2
RSLVY LinRespSpec Max 0 453 0
QKX LinStatic -541 0 0
QKY LinStatic 0 -539 0
QKEX Combination Max 540 136 740
QKEX Combination Min -540 -136 736
QKEY Combination Max 162 453 738
QKEY Combination Min -162 -453 737
FINAL (100% design) DESIGN ANALYSIS Pag.27 di 67
Blocco B – Stato di progetto
Reazioni alla base
Si riportano di seguito le azioni globali alla base della struttura per le diverse condizioni e combinazioni di carico.
TABLE: Base Reactions
OutputCase CaseType StepType GlobalFX GlobalFY GlobalFZ
Text Text Text KN KN KN
DEAD LinStatic 0 0 404
G1 LinStatic 0 0 235
G2 LinStatic 0 0 164
Qh LinStatic 0 0 48
QS LinStatic 0 0 114
RSLVX LinRespSpec Max 515 2 5
RSLVY LinRespSpec Max 2 484 2
STR1 Combination 0 0 1043
STR2 Combination 0 0 1043
STR3 Combination 0 0 1215
STR4 Combination 0 0 1129
QKEX Combination Max 516 147 808
QKEX Combination Min -516 -147 797
QKEY Combination Max 156 485 806
QKEY Combination Min -156 -485 799
FINAL (100% design) DESIGN ANALYSIS Pag.28 di 67
FINAL (100% design) DESIGN ANALYSIS Pag.29 di 67
CAPITOLO 2.10 VERIFICHE STRUTTURALI
Le verifiche sono state condotte con il codice di calcolo SAP2000 v 20.1.0 e con il programma di verifica per sezioni generiche VIS versione 11 della CSi Italia srl. I parametri normativi e le formulazioni seguite nelle verifiche sono quelle previste dalle NTC 2018.
A’s
As c1 sy cu su fcd fyd
−sy −su
3 4
FINAL (100% design) DESIGN ANALYSIS Pag.30 di 67
Il metodo utilizzato per la generazione del dominio di interazione triplo P-M2-M3 è quello dello stress-block.
Le verifiche a presso flessione deviata vengono condotte calcolando il fattore di utilizzo, ovvero, il rapporto tra l’azione sollecitante e quella resistente ottenuta con il metodo della eccentricità costante.
Le verifiche ed il relativo calcolo del coefficiente di utilizzo, espressione diretta della capacità di resistenza della struttura, rispetto alle caratteristiche di sollecitazione a cui essa è sottoposta, sono calcolati su questo piano, semplicemente prolungando la direttrice (0, 0, 0) – (N, Mx, My) e determinandone l’intersezione sulla curva di dominio.
Definendo (N1, Mx1, Mx1) la terna delle sollecitazioni che individuano uno stato di sollecitazione e (Nv, Mxv, Myv) il relativo punto sul dominio, ottenuto prolungando tale direttrice, il coefficiente di utilizzo è determinato come rapporto delle due distanze:
Le verifiche a tenso/presso flessione deviata includono gli effetti dovuti alle imperfezioni geometriche ed agli effetti del secondo ordine secondo la trattazione della colonna modello.