SECTION J ATTACHMENT 01 ARCHITECTURAL COMPATIBILITY STANDARD ANNEX 31 d
View the file
Other files for this federal contract opportunity
Show all 50
Air Force Multiple-Award Construction IDIQ, Germany has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A C S A r c h i t e c t u r a l C o m p a t i b i l i t y S t a n d a r d R A M S T E I N A I R B A S E
Edition 2008
DEPARTMENT OF THE AIR FORCE
435TH AIR BASE WING (USAFE)
MEMORANDUM FOR 435 ABW
FROM: 435 ABW/CC
SUBJECT: KMC Architectural Compatibility Standards
1. As the 435th Air Base Wing Commander, I am proud to present the Architectural Compatibility Standards (ACS) to the men and women of the Kaiserslautern Military Community. Ramstein AB and the units within the community play a vital role in the Global War on Terrorism from world-class airlift support to providing combat-ready forces for world-wide deployment. These standards are key to our vision…Expeditionary Airmen transforming European Command’s premier airlift hub to the “Gateway to Peace” for the 21st Century.
2. We have an obligation to use Air Force resources as efficiently as possible. Accordingly, when making decisions regarding the development of the KMC, we need to have the right information available. The ACS provides the information and guidance necessary to make sound decisions in facility and community design and construction.
3. The Architectural Compatibility Standards provide our civil engineers, designers and contractors the guidance to achieve a well-planned and high-quality visual environment that exceeds Air Force and German standards. They also provide consistency in construction and design across all aspects of the built environment and also create a common level of understanding on how to design future projects for the Kaiserslautern Military Community.
4. It is a three-step process to fully utilize the ACS. First, all commanders and functional managers on Ramstein AB and the associate Air Force units of the KMC should comply with the ACS.
Second, all future programs should be reviewed for compliance with these standards. Finally, the standards should be reviewed regularly and updated as needed to keep the document relevant and accurate.
3. The 435th must continue to design intelligently so we can provide the best communities and facilities for our people. I endorse these standards and believe that through them we can enhance our mission capability and provide the highest possible quality of life.
EARL D. MATTHEWS
Colonel, USAF Commander
Table of Contents
Architectural Compatibility Standard for Ramstein Air Base 3
SECTION I INTRODUCTION
Part 1.00 Overview 05 - 06
1.1 Use, Scope and Purpose 06
Part 2.00 Background Information 07 - 14
2.1 District Overview 08
2.2 Type of Building 09
2.3 District Scheme 10-14
SECTION II DESIGN STANDARDS
Part 1.00 Building Exterior Standard 15 - 40
1.0 List of Contents 16
1.1 Roof 17 - 19
1.2 Roof Drainage 21 - 22
1.3 Façade 23 - 26
1.4 Façade Elements 27 - 28
1.5 Balconies/Railings, Emergency Stairs 29 - 30
1.6 Windows/Doors 31 - 33
1.7 Entry Components 35 - 36
1.8 Others 37 - 39
Part 2.00 Building Interior Standard 41 - 66
2.0 List of Contents 42
2.1 Application Matrices 43 - 48
2.2 Floor Finishes 49 - 52
2.3 Wall Finishes 53 - 54
2.4 Ceiling Finishes 55 - 56
2.5 Windows 57
2.6 Doors 58
2.7 Stairs 59 - 60
2.8 Stair Railings 61
2.9 Lighting 62 - 63
2.10 Signage 64 - 65
Part 3.00 Streetscape Standard 67 - 107
3.0 List of Contents 68
3.1 Paving and Stairs 69 - 76
3.2 Furnishings 77 - 84
3.3 Fences, Walls and Dumpster 85 - 91
3.4 ATFP 93 - 96
3.5 Signage 97 - 107
Part 4.00 Landscape Standard xxx
Part 5.00 Related Standards xxx
Section I Introduction Overview Part 1.00
Overview Ramstein Air Base Compatibility Standard Overview 1.1
Architectural Compatibility Standard for Ramstein Air Base 6
OVERVIEW
This Architectural Compatibility Standard (ACS) is a reference document and tool to provide a quality built environment at Ramstein Air Base. It provides the standards and recommendations for all building, landscape and streetscape installations within the base.
The ACS has been organized into two (2) Sections (I and II) as follows:
SECTION I INTRODUCTION
Section I overviews the expected use and explains how to use this document.
Section I also defines the five (5) districts on Ramstein Air Base and the different types of buildings within those districts.
SECTION II ARCHITECTURAL COMPATIBILITY
STANDARDS
Section II defines the standards for different building, streetscape and landscape elements within each district. Each building, streetscape and landscape section begins with an application matrix that defines the type, material, shape, color, etc. based upon the district and type of building. The sections also provide general information and technical details on each type of material and element within the matrix.
Design standards will differ based upon which district the proposed element will be located.
For example, a Flightline District administrative building might have different characteristics (color, material, roof shape, etc) than one located in the Community District. Additionally, design standards will also vary across the different types of buildings within that district.
For example, an administration building might have different characteristics (material, roof shape, etc) than an industrial building within the same district
HOW TO USE THIS STANDARD
The ACS user should first define which district the building, streetscape or landscape element will be located (Section I, 2.1).
The user should then determine the intended use of the facility (Section I, 2.2) and become familiar with the respective district themes (Section I, 2.3). Once the district and building type are defined, the user can then determine each building exterior (Section II, 1.0), building interior (Section II, 2.0), streetscape (Section II, 3.0), and landscape (Section II, 4.0) element for the facility.
STANDARDS AND RECOMMENDATIONS
If an obligatory standard, such as Unified Facilities Codes, Air Force Instructions, building codes, manuals, etc, is noted within this document then the standard shall be considered mandatory. In the case where obligatory standards are not defined or listed as a recommendation, then the ACS user will have several choices based upon the base common practices.
SCOPE
All proposed designs must receive approval from the BCE or his appointed designee prior to execution. No deviations to the standards in this ACS will be allowed without written approval from the BCE.
The NATO are not part of the ACS, the buildings are subjected to special requirements.
PURPOSE
This standard represents the architectural standards to be used by the Base Civil Engineer’s (BCE) staff and its agents to systematically upgrade the physical features on base. The application of these standards will eventually result in a fully functional architecturally compatible environment. These standards apply to all exterior and interior features that contribute to the visual environment of RAB.
These standards have been developed to provide designers with a check list of architectural components necessary to achieve compatibility with architectural styles on RAB.
- The standard defines the basic theme and appropriate styles in the KMC
- It covers typical building elements, colors, materials and furnishings that are mandatory for use to achieve the best architectural interior and exterior environments.
- It provides different specific standards to direct the appearance of all installations:
“Building Exterior Standard”, “Building Interior Standard”, “Streetscape Standard”, “Landscaping Standard” and “Related Standards”
The Architectural Compatibility Standard based on the Area Development Plans that has been super ceded by the General Plan.
The Standards may vary from geographically separated areas of the base know as visual districts: (ADP1 – ADP6)
Section I Introduction Background Information Part 2.00
Background Information District Overview 2.1
Architectural Compatibility Standard for Ramstein Air Base 8
GENERAL INFORMATION
The Ramstein Air Base General Plan and Area Development Plans (ADPs) divide the base into five ( 5 ) distant visual districts:
• COMMUNITY DISTRICT
• INDUSTRIAL DISTRICT
• FAMILY HOUSING DISTRICT
• ADMINISTRATIVE DISTRICT
• WEST END FLIGHTLINE DISTRICT
Different design standards apply within the individual districts.
Type of Building 2.2
Architectural Compatibility Standard for Ramstein Air Base 9
Different architectural styles might appear within the individual districts based upon building type and usage.
The building interior work standard is divided into a standard quality level and a high quality level. Final determination of the level must be approved by BCE.
Administrative Buildings Most part of the building provided with offices.
Dormitory Buildings Dormitory for permanent accommodation of unaccompanied persons.
Family Housing Buildings Building suitable for permanent accommodation of families.
Lodging (Hotel) Buildings These buildings are used for temporary accommodation of persons.
Community Service Buildings As a rule, these buildings are public facilities and open to the public;
e.g. clubs, commissary, fitness center, chapel, school or dining hall.
Industrial Buildings Industrially used building such as maintenance facilities, material support facilities;
e.g. shops, hangars, sheds.
Utility Buildings e.g. transformer stations
Parking Garages
Other Buildings These secondary buildings should adapt to the surrounding area and must be approved by the BCE.
e.g. kiosk, gatehouse, guardhouse, equipment house , technical equipment, permanently installed equipment (satellite installation, tanks etc)
Prefabricated Buildings These buildings are temporary facilities consisting of prefabricated containers.
They are multi-functional buildings ( e.g. site facilities; office and material containers).
These facilities are not part of the ACS, they are subjected to special requirements which must be approved in individual cases.
Example: Hercules Theater No. 2101
Example: Dormitory No.2418
Example: Elementary School Class No. 904
Example: Parking Garage
District Scheme 2.3
Architectural Compatibility Standard for Ramstein Air Base 10
COMMUNITY DISTRICT
Main Facade
Material: Plaster Color: RAL 080 8010 Beige Material: Exposed masonry façade Color: Beige Red
Accent (Walls/Entry Components Etc)
Material: Sandstone Color: Red Material: Granite Color: Anthracite
Color: RAL 1002 Sand yellow
Doors/Windows/Frames Material: Aluminum, steel, PVC Color: RAL 8014 Sepia brown
RAL 7016 Anthracite
Roof
Material: Metal
Stairs/Railing Material: Steel Color: RAL 8014 Sepia brown RAL 7016 Anthracite
RAL 9006 White aluminum
Stainless steel Galvanized
Elements of Building 1 Facade 2 Accent: Wall, Pillar, Entry Components, etc.
3 Doors, Windows, Frames 4 Roof 5 Railings/Emergency Stairs
Example: Enlisted Club No. 2140
Example: KMCC No.
Example: Dormitory No. 2486
Example: Fitness Center No. 2117
Architectural Compatibility Standard for Ramstein Air Base 11
INDUSTRIAL DISTRICT
Material: Metal, plaster Color: RAL 080 8010 Beige
Color: Yellow
Material: Plaster
RAL 8014 Sepia brown
Material: Steel, aluminum
Color: RAL 8014 Sepia brown RAL 9006 White aluminum Galvanized
Elements of Building
1 Facade 2 Accent: Wall, Pillar, Entry Components, etc 3 Doors, Windows, Frames
Example: Warehouse No. 2246
Example: Operational Headquarter No. 2388
Example: DELTA Squadron OPS No. 2200
Example: ELVIS No. 2900
Architectural Compatibility Standard for Ramstein Air Base 12
WEST END FLIGHTLINE DISTRICT
Material: Metal, plaster
Color: RAL 9006 White aluminum RAL 9007 Gray aluminum
Material: Metal, Plaster
Color: RAL 9006 White aluminum
RAL 9007 Gray aluminum RAL 7022 Umbra gray RAL 7035 Light gray
Material: Steel, Aluminum
Color: RAL 9006 White aluminum
Color: RAL 9006 White aluminum
Color: Galvanized RAL 9006 White aluminum
RAL 9007 Gray aluminum
RAL 7022 Umbra gray
RAL 7035 Light gray Stainless steel
Elements of Building 1 Facade 2 Accent: Wall, Pillar, Entry Components, etc 3 Doors, Windows, Frames
Example: Air Freight Terminal No. 3334
Example: Passenger Terminal No. 3333
Example: Hangar V No. 3330
Example: Flight Kitchen No.3332
Architectural Compatibility Standard for Ramstein Air Base 13
FAMILY HOUSING DISTRICT
Color: Red
Color: RAL 1002 Sand yellow
Material: Aluminum, PVC
Material: Concrete/clay tiles, metal
Color RAL 8014 Sepia Brown
RAL 9006 White aluminum
Stainless steel
2 Accent: Wall, Pillar, Entry Components, etc 3 Doors, Windows, Frames
Example: Town Houses in Vogelweh
Example: Town Houses in Vogelweh
Example: Stairwell Housing Unit
Example: General Housing
Architectural Compatibility Standard for Ramstein Air Base 14
ADMINISTRATIVE DISTRICT
Color: RAL 080 8010 Beige
Accent (Walls/Entry Components Etc) Material: Sandstone Color: Red
Doors/Windows/Frames Material: Aluminum
Color: RAL 8014 Sepia brown
RAL 9006 White aluminum
2 Accent: Wall, Entry Components, etc.
3 Doors, Windows, Frames
Example: Building No. 2251
Example: Parking Garage No.2255
Example: CRS No.2248
Example: Admin No.573
Section II Design Standards Building Exterior Standard Part 1.00
Building Exterior Standard List of Contents 1.0
Architectural Compatibility Standard for Ramstein Air Base 16
Part 1.00 Building Exterior Standard 15-40
1.1 Roof
1.1.1 Application Matrix 17
1.1.2 General Information 18
1.1.3 Tiled Roofs 18
1.1.4 Standing Seam; Metal Clad Roofs 19
1.1.5 Flat Roofs 19
1.1.6 Landscaped Roofs 19
1.2 Roof Drainage
1.2.1 Application Matrix 21
1.2.2 General Information 22
1.3 Façade
1.3.1 Application Matrix 23
1.3.2 General Information 24
1.3.3 Plaster Facades 24
1.3.4 Exposed Masonry Facades 25
1.3.5 Metal Facades 25
1.3.6 Panelled Facades 25
1.3.7 Natural Stone Facades 26
1.3.8 Façades Base and Grade Connections 26
1.4 Façade Elements
1.4.1 Application Matrix 27
1.4.2 General Information 28
1.4.3 Pillar/Column 28
1.4.4 Ceiling Soffits 28
1.5 Balconies/Railings and Emergency Stairs
1.5.1 Application Matrix 29
1.5.2 General Information 30
1.5.3 Balconies/Railings 30
1.5.4 Emergency Stairs 30
1.6 Windows/Doors
1.6.1 Application Matrix 31
1.6.2 General Information 32
1.6.3 Doors 32
1.6.4 Windows 32
1.6.5 Shutters and louvers 33
1.7 Entry Components
1.7.1 Application Matrices
1.7.2 General Information 35
1.7.3 Entry Components 36
1.8 Others
1.8.1 Application Matrix 37
1.8.2 General Information 38
1.8.3 Exterior Signage 38
1.8.4 Exterior Lighting 39
Roof 1.1
Architectural Compatibility Standard for Ramstein Air Base 17
1.1.1 Application Matrix
COMMUNITY
DISTRICTS
ROOF TYPES ROOF
PITCH MATERIAL COLOR
Administrative Buildings
Community Service Buildings
Utility Buildings
6° - 30° Standing seam; metal clad roofs RAL 8014 Sepia brown
Parking Garage 1.2°-6° Road course, gravel course, plants Gray, green and brown
INDUSTRIAL
DISTRICTS
ROOF TYPES ROOF
PITCH MATERIAL COLOR
Administrative Buildings Industrial Buildings Utility Buildings
6° - 30° Standing seam; metal clad roofs RAL 8014 Sepia brown
Parking Garage 1.2°-6° Road course, gravel course, plants Grey, green and brown
FAMILY HOUSING
ROOF TYPES ROOF
PITCH MATERIAL COLOR
Dormitory Buildings
Family Housing Buildings
Utility Buildings
6° - 30° Concrete tile roofs, Lacquered clay tile roofs Standing seam; metal clad roofs
ADMINISTRATIVE
ROOF TYPES ROOF
PITCH MATERIAL COLOR
Administrative Buildings Community Service Buildings
Utility Buildings
6° - 30° Standing seam; metal clad roofs RAL 8014 Sepia brown
WEST END FLIGHT-
LINE DISTRICTS
ROOF TYPES ROOF
PITCH MATERIAL COLOR
Administrative Buildings Community Service
Industrial Buildings
6° - 30° Standing seam; metal clad roofs RAL 9006 With alu
*Roof Types see chapter 1.1.2 General Information
Architectural Compatibility Standard for Ramstein Air Base 18
1.1.2 General Information
Roof types The roof type effects the building enormously, especially in case of sloping roofs. The roof type is defined by many components:
• roof pitch
• roof type
• roof type combination
• roof superstructures
• roof projection
• cornice and verge construction
• structure of the roofing material
• surface of the roofing material
• color of the roofing material
If possible, mechanical equipment should be installed in the building and hidden underneath the roof covering. If mechanical equipment is installed on the roof, then visual screening should be provided.
Roof Overhang The roof overhang finish should be the same color as the roofing.
Gable roof
Shed roof
Hip roof
Low slope roof
Combination of various roof types
Arched roof
Example: Concrete Roofing Tile
Material: Concrete
Example: Clay Roofing Tile
1.1.3 Tiled Roofs
Concrete Tile Roof
→ mainly for the family housing districts.
The usage in other districts must be approved in individual cases by the BCE.
Technical Information Concrete roof tiles should generally be used for a roof pitch of 22° - 45°. They can also be used for flatter or/steeper roofs to provide additional protective measures.
However, German DIN and EnEV regulations require a sub-roof on low pitch tile roofs (less than 22°).
The tile finish should have a treatment to allow for better cleansing.
Snow guards and/or snow stop tiles should be installed in areas where snow can accumulate (eaves, valleys, etc).
Clay Tile Roof
→ mainly for the family housing districts.
The usage in other districts must be approved in individual cases by the BCE.
Clay roof tiles should generally be used for a roof pitch of 22° to 45°.
They can also be used for flatter/steeper roofs to provide additional protective measures. However, German DIN and EnEV regulations require a sub-roof on low pitch tile roofs (less than 22°).
Lacquered clay tiles can be used, wherever concrete tiles are allowed to be used, because they can be manufactured in various colors and are easier to maintain.
Snow guards and/or snow stop tiles should be installed in areas where snow can accumulate (eaves, valleys, etc).
Material: Clay
Architectural Compatibility Standard for Ramstein Air Base 19
Example: Metal Panels
1.1.4 Standing Seam Metal Clad Roofs
→ All districts to all building types
Standing seam metal-clad roofs are especially suitable for large roof areas and spans. Sectional aluminum panels should generally be used for roof pitches of 1,5° to 20° with the idealroof pitch at 15°.
Continuous metal elements shall be installed from the eaves to the ridge. However, large panel lengths might depend on which type of shipping methods are used to get the material on site.
Material: Aluminum, steel
RAL 9006 White aluminum
Utility Building KMCC Example: Hardstand for Mechanical Equipment
1.1.5 Low Slope Roofs
→ All districts: mainly for parking garages or hardstands for mechanical equipment.
Normally the upper floor should be designed without a roof. Because of susceptibility to icing only the ramps are canopied.
Depending upon their usage, parking garages roofs should be finished with a top road course (park deck), gravel course, landscaping or a combination of these. Since major roof loads occur, solid slab systems, such as hollow reinforced concrete slabs or sectional sheet steel – bonded systems, are recommended.
State of the art waterproofing membranes should be used.
Bituminous waterproofing should not be used.
Material: Road course, gravel course, plants Color: Gray, green, brown
Example: Landscaped Roof
1.1.6 Landscaped Roofs
→ All districts: mainly for new parking garages with rooftops → All districts: bermed buildings
Landscaped roofs have strong positive environmental benefits;
rainfall retention at 50% to 90% and delayed water run-off relieving the storm drainage system. However, one of the main negative aspects is that landscape roofs require stronger load-bearing slabs to support the additional weight of the landscaping.
Technical Information The sub construction of the roof should built up with a low slope.
Extensive landscaping should be used, since it requires little maintenance efforts once placed. Roof inlets, connections, enclosures, penetrations, etc should be kept free from landscaping and must be accessible at all times. A gravel strip around such items is recommended.
Material: Plants Color: Green, brown
Roof Drainage 1.2
Architectural Compatibility Standard for Ramstein Air Base 21
1.2.1 Application Matrix
DISTRICTS
MATERIAL TYPE
GUTTER / DOWNSPOT
GUTTER
COLOR
DOWNSPOT
COLOR
Administrative Buildings Aluminum Zinc
Aluminum Copper
Community Service
Utility Buildings
Parking Garage
RAL 8014Sepia brown
Galvanized
RAL 080 8010 Beige
MATERIAL TYPE
GUTTER / DOWNSPOT
GUTTER
COLOR
DOWNSPOT
COLOR
Administrative Buildings
Industrial Buildings Utility Buildings
Parking Garage
Galvanized
MATERIAL
TYPE
GUTTER /
DOWNSPOT
GUTTER
COLOR
DOWNSPOT
COLOR
Dormitory Buildings
Family Housing Buildings Utility Buildings
Parking Garage
Galvanized
MATERIAL TYPE
GUTTER / DOWNSPOT
GUTTER
COLOR
DOWNSPOT
COLOR
Administrative Buildings Community Service Buildings Utility Buildings
Parking Garage
Galvanized
MATERIAL TYPE
GUTTER / DOWNSPOT
GUTTER
COLOR
DOWNSPOT
COLOR
Administrative Buildings Community Service Buildings Industrial Buildings
Utility Buildings
Parking Garage
RAL 9006 White alu
Roof Drainage 1.2
Architectural Compatibility Standard for Ramstein Air Base 22
1 End filler 2 Semi-circular roof gutter 3 Gutter bracket 4 Gutter angle 5 Gutter outlet 6 Conduit bend 7 Bang clamp 8 Welded downspout 9 Rain collecting-plug-in termination
Example: Roof Gutter and Downspout
1.2.2 General Information
Roof drainage is mandatory for every roof type. All sloped roofs will be drained via exterior roof gutters at the eaves and all flat roofs via interior drains. There are many gutter manufacturers with various gutter systems in numerous forms and materials.
Semi-circular gutters with round downspouts should be used for
→ All districts to all buildings except for community service buildings where concealed gutters are recommended
Form Generally, semi-circular suspended gutters should be used throughout the base. Only community service buildings should receive concealed gutters and downspouts, preferably located in the exterior walls.
Shingled roofs covered should be provided with a verge gutter at the verge (gable).
Color Box gutters should be coated in the same RAL-tone as the roofing.
Raingutters and downspouts in the area of the façade should be painted in the same color tone as the facade and those in the area of the wall base and/or eaves should be painted in the color shade of the latter.
Concealed Roof Gutters If the eaves area is to be fully concealed for design considerations, gutters should be installed as shown on the adjacent drawing.
Interior Roof Gutters Interior gutters are only acceptable in exceptional cases (e.g. existing buildings). In these cases, gutters should be provided with gutter insulation and vapor barrier.
Overflow scuppers should be provided for all interior roof gutter systems to prevent backwash and roof damage due to clogged drains.
Protective Measures Roof gutters in areas with trees should be provided with leaf-stop cages to prevent soiling/clogging. Another option is to use box gutters.
Downspouts should be protected by a steel standpipe at their base.
Downspouts should never be drained on to the ground without providing landscape protection (splash blocks, filtering, etc.)
Clean out pieces shall be installed in the downspout, so that cleaning with high pressure washers and maintenance are easier and less cost intensive.
RAL 7016 Anthracite
RAL 9006 White aluminum
Facade 1.3
Architectural Compatibility Standard for Ramstein Air Base 23
1.3.1 Application Matrix
DISTRICTS
FAÇADE
MATERIAL
FAÇADE
COLOR
FAÇADE BASE
MATERIAL
FAÇADE BASE
COLOR
Administrative Buildings Plaster facade Red sandstone
Plaster Gray basalt, granite
RAL 8014 Sepia brown Granite Gray basalt
Dormitory Buildings Lodging (Hotel) Buildings
Plaster facade Plaster RAL 8014 Sepia brown
Community Service Buildings Parking Garage
Expo. masonry facade Red sandstone Plaster facade
Expo. masonry Gray basalt, granite
Plaster
RAL 8014 Sepia brown Granite Gray basalt
Utility Buildings Plaster facade
Plaster RAL 8014 Sepia brown
FAÇADE
MATERIAL
FAÇADE
COLOR
FAÇADE BASE
MATERIAL
FAÇADE BASE
COLOR
Administrative Buildings Industrial Buildings Parking Garage Utility Buildings
Plaster façade
Metal facade RAL 080 8010 Beige Plaster facade Metal façade
Concrete
FAÇADE
MATERIAL
FAÇADE
COLOR
FAÇADE BASE
MATERIAL
FAÇADE BASE
COLOR
Dormitory Buildings RAL 080 8010 Beige Plaster
Gray basalt RAL 8014 Sepia brown Gray basalt
Family Housing Buildings
Plaster facade
Yellow sandstone RAL 080 8010 Beige
Plaster
Granite
RAL 8014 Sepia brown Granite Gray basalt
Parking Garage
Plaster facade RAL 080 8010 Beige Plaster RAL 8014 Sepia brown
FAÇADE
MATERIAL
FAÇADE
COLOR
FAÇADE BASE
MATERIAL
FAÇADE BASE
COLOR
Administrative Buildings Community Service Buildings
Plaster facade Red sandstone
Plaster Gray basalt
Granite
RAL 8014 Sepia brown Granite Gray basalt
Parking Garage Utility Buildings
Plaster facade
Plaster RAL 8014 Sepia brown
FAÇADE
MATERIAL
FAÇADE
COLOR
FAÇADE BASE
MATERIAL
FAÇADE BASE
COLOR
Administrative Buildings Community Service Buildings Industrial Buildings Parking Garage Utility Buildings
Plaster facade Metal facade
RAL 9006 White alu RAL 9007 Gray alu
Plaster Metal
Architectural Compatibility Standard for Ramstein Air Base 24
1.3.2 General Information
Accents Accents are structural components (15%) with proportions clearly secondary to the main façade.
Buildings for children are allowed to use other accent colors like the standard and must be approved in individual cases by the BCE.
Additions Major building additions that add more than 30% to the façade must follow the ACS. Minor building additions should match the existing building façade even if it is not current standard.
Admin No. 573
Example: Plaster Facade
Color: Façade: RAL 080 8010 Beige
RAL 9006 White aluminum
RAL 9007 Gray aluminum
Base: RAL 8014 Sepia brown
1.3.3 Plaster Façades
Plaster facades could be used for the following functions and/or districts:
→ All district to all building types
Generally, two types of plaster are applied - lime plaster (Kalkputz) and cement plaster (Zementputz). These are categorized into insulation, heavy and light plasters. All exterior plasters must be weather-, frost- and temperature-resistant, color-retaining, well bonding, sufficiently hard, crack-free, efflorescence-free and self cleaning. Cement plasters are used for the base since they are resistant to capillary and splashing water.
Silicone resin plasters are recommended for thermal insulation exterior wall system (WDV-System).
Execution Rough cast/grain size 1,5–3,0 mm Application: Spray plaster/toweling
Published US and German regulations require that buildings be thermally insulated according to U-factors for energy conservation purposes. New buildings must be designed to comply with these regulations. Exterior building insulation should be applied to meet these building regulation requirements. If buildings are being renovated and/or altered, they are required to meet the same regulations. Basement walls should receive perimeter insulation only around conditioned room. An energy certificate shall be prepared for new construction measures.
Algaecides and fungicides shall be incorporated into the exterior plaster.
The plaster wall build up shall also meet the base, DIN 4108 and EnEV sound insulation requirements.
Example: Structure of Plaster Facade
Architectural Compatibility Standard for Ramstein Air Base 25
Elementary School No. 996 Example: Exposed Masonry Façade,
1.3.4 Exposed Masonry Facades
Exposed masonry facades are high-quality exterior wall finishes:
→ Community service buildings:
school and child care center buildings
This exterior wall construction consists of a double-shell with thermal insulation in between.
Minimum thickness of outer shell: 90mm Masonry piers in exterior shell: L ≥ 24cm
The exterior shell must be self-supporting over the entire length of the façade and must meet Anti-Terrorism/Force Protection standards.
Material: Exposed masonry façade Color: Beige Red
1.3.5 Metal Facades
Facades and walls finished with sectional aluminum panels should generally be used in
→ Industrial and flightline districts:
all building types
Only insulated facades should be constructed. Gable roofs should be used to blend with the surrounding buildings.
Example: Types of Metal Panels Example: Metal Façade
Material: Aluminum, steel Color: RAL 9002 Gray-white
Example: Paneled Facade
1.3.6 Paneled Facades
Large-sized façade sheeting of fiber-cement panels can be used for new facilities as well as for repairing of existing facades. These panels can be mounted on an aluminum or steel supporting sub frame or on masonry as shown in the details opposite.
A roof overhang of 60cm minimum is recommended for all paneled wall sheeting.
Exterior wall finishing should be installed at a minimum distance of min. 20mm in front of thermal insulation/wall surfaces.
Ventilation openings of 50cm² must be provided per linear meter wall length. Insect mesh must be provided at ventilation openings to prevent penetration into air spaces.
Only manufacturers and systems that are proven and experienced should be used.
Material: Fiber-cement Color: RAL 9002 Gray-white
Architectural Compatibility Standard for Ramstein Air Base 26
Enlisted Club Building No. 2140
Theater Building No. 2101 Example:
Facade: Sandstone, red
Facade: Sandstone, yellow
1.3.7 Natural stone Facades
Sandstone and granite facades are high-quality exterior wall finishes:
→ community district:
administrative and community service buildings
→ family housing district:
dormitory, family housing and parking garage buildings
→ administrative district:
administrative and community service buildings
Bonded thermal insulation system with plaster finish:
→ Community , family and administrative district to administration, dormitories, family housing, community service buildings and prefabricated buildings
Veneer facades:
→ Community and administrative district to community service buildings
Exposed masonry/double-shell:
→ Community districts to child care centers and schools
Color: Yellow Red
Material: Granite
Color:
Hangar V No. 3330
Building No. 2245
Facades Base: Concrete
Facades Base: Granite
1.3.8 Facades Base and Grade Connection
Good detailing of the wall base and connection at the grade will avoid permanent moisture problems. Careful attention to this detailing prevents maintenance problems.
The base detail depends upon the selected façade system.
Standard solutions for various systems are described below:
Bonded thermal insulation system with plaster finish:
→ Community , family and administrative district to administration, dormitories, family housing, community service buildings and prefabricated buildings
Veneer facades:
→ Community and administrative district to community service buildings
Exposed masonry/double-shell:
→ Community districts to child care centers and schools
Material: Plaster, concrete, metal, granite, gray basalt, Gray
RAL 9007 Gray aluminum
RAL 7022 Umbra gray
Granite
Façade Elements 1.4
Architectural Compatibility Standard for Ramstein Air Base 27
1.4.1 Application Matrix
PILLARS, COLUMNS CEILING SOFFITS COMMUNITY
DISTRICTS MATERIAL COLOR MATERIAL COLOR
Administrative Buildings Plaster facade Red sandstone
Dormitory Buildings Lodging (Hotel) Buildings
Plaster facade
Community Service Buildings
Plaster Steel
Fiber-cement Wood
RAL 080 8010 Beige RAL 7035 Light gray RAL 9016 Traffic white Natural wood
Parking Garage
Expo. masonry Red sandstone Plaster facade
RAL 080 8010 Beige
N/A Utility Buildings N/A N/A
PILLARS, COLUMNS CEILING SOFFITS INDUSTRIAL
DISTRICTS MATERIAL COLOR MATERIAL COLOR
Administrative Buildings
Industrial Buildings
Plaster Steel
Fiber-cement Wood
RAL 080 8010 Beige RAL 7035 Light gray RAL 9016 Traffic white Natural wood
Parking Garage
Plaster façade
Metal facade RAL 080 8010 Beige
PILLARS, COLUMNS CEILING SOFFITS FAMILY HOUSING
Dormitory Buildings RAL 080 8010 Beige
Family Housing Buildings RAL 080 8010 Beige RAL 1002 Sand yellow
Plaster Steel
Fiber-cement Wood
RAL 080 8010 Beige RAL 7035 Light gray RAL 9016 Traffic white Natural wood
Parking Garage
Plaster facade Yellow sandstone
PILLARS, COLUMNS CEILING SOFFITS ADMINISTRATIVE
Administrative Buildings
Community Service Buildings
Plaster Steel
Fiber-cement Wood
RAL 080 8010 Beige RAL 7035 Light gray RAL 9016 Traffic white Natural wood
Parking Garage
Plaster facade Red sandstone Plaster facade
PILLARS, COLUMNS CEILING SOFFITS WEST END FLIGHT-
LINE DISTRICTS MATERIAL COLOR MATERIAL COLOR
Administrative Buildings Community Service Buildings Industrial Buildings
Plaster Steel Wood
Fiber-cement
RAL 080 8010 Beige RAL 7035 Light gray RAL 9016 Traffic white
Parking Garage
Plaster facade Metal facade
RAL 9007 Gray alu RAL 7022 Umbra gray RAL 9006 White alu
Façade Elements 1.4
Architectural Compatibility Standard for Ramstein Air Base 28
1.4.2 General Information
Façade elements include pillars, columns and ceiling soffits.
Building No. 2245 Fitness Center No.2117 Example: Pillars, Columns
1.4.3 Pillars, Columns
The pillars and columns could be used as accents in the façade of a building.
Color and material could be the same as the façade or as accent different.
Pillars and columns are to be seen in connection with the facades described in item 1.3.
Material: Steel, plaster, sandstone(red, yellow), expo. masonry
RAL 8014 Sepia brown RAL 1002 Sand yellow
Fitness Center No. 2117 Example: Ceiling Soffits
1.4.4 Ceiling Soffits
Outdoor ceiling soffits are to be seen in connection with the façade design and as such should blend with overall design.
Material type depends on building fire codes and façade design.
However, ceiling soffits shall be coated with light color shades regardless of the selected material.
Material: Steel, plaster, natural wood, painted wood, fiber-cement panel Color: RAL 080 8010 Beige
RAL 7035 Light gray
RAL 9016 Traffic white
Natural wood
Balconies/Railings and Emergency Stairs 1.5
Architectural Compatibility Standard for Ramstein Air Base 29
1.5.1 Application Matrix
BALCONIES/ RAILING EMERGENCY STAIRS COMMUNITY
DISTRICTS MATERIAL COLOR MATERIAL COLOR
Administrative Buildings Plaster
Red sandstone, granite Steel
Dormitory Buildings
Lodging (Hotel) Buildings Plaster Steel
Community Service Buildings
Expo. masonry Plaster
Red sandstone, Granite Steel
Parking Garage Plaster Steel
Galvanized Stainless steel RAL 080 8010 Beige RAL 8014 Sepia brown RAL 7016 Anthracite
Plaster Steel
Galvanized Stainless steel RAL 080 8010 Beige
BALCONIES/ RAILING EMERGENCY STAIRS INDUSTRIAL
Administrative Buildings Plaster Steel
Industrial Buildings
Parking Garage Steel
Galvanized RAL 080 8010 Beige RAL 8014 Sepia brown
Plaster Steel
Galvanized
BALCONIES/ RAILING EMERGENCY STAIRS FAMILY HOUSING
Dormitory Buildings
Family Housing Buildings
Parking Garage
Plaster Yellow sandstone
Steel
Galvanized Stainless steel RAL 080 8010 Beige RAL 8014 Sepia brown RAL 1002 Sand yellow
Plaster Steel
Galvanized Stainless steel RAL 080 8010 Beige
RAL 1002 Sand yellow
BALCONIES/ RAILING EMERGENCY STAIRS ADMINISTRATIVE
Administrative Buildings Community Service Buildings
Parking Garage
Plaster Red sandstone
Steel
Galvanized Stainless steel RAL 080 8010 Beige RAL 8014 Sepia brown RAL 1002 Sand yellow
Plaster Steel
Galvanized Stainless steel RAL 080 8010 Beige
RAL 1002 Sand yellow
BALCONIES/ RAILING EMERGENCY STAIRS WEST END FLIGHT-
Administrative Buildings Community Service Buildings Industrial Buildings
Parking Garage
Plaster Steel
RAL 9006 White alu RAL 9007 Gray alu RAL 7022 Umbra gray RAL 7035 Light gray Stainless steel Galvanized
Plaster Steel
Galvanized Stainless steel RAL 9006 White alu RAL 9007 Gray alu
Balconies/Railings and Emergency Stairs 1.5
Architectural Compatibility Standard for Ramstein Air Base 30
1.5.2 General Information
Balconies are only authorized for → family housing district to family housing buildings
However, fire escape balconies are present in → all districts to all building types
Balconies, fire escape balconies, outdoor corridors and emergency stairs can be different from the façade by painting or material.
Family Housing No.845 Dormitory No.2418
Example: Balconies/Outdoor Corridor
1.5.3 Balconies/Railings
Balconies Balconies for family units should be self-supporting reinforced structures on concrete foundations with galvanized vertical railing elements.
The standard for the base is illustrated by the adjacent photographs of Building 845.
Fire Escape Balconies Fire escape balconies must meet all NFPA construction and material requirements and standards.
Outdoor Corridors Outdoors corridors are used mainly for dormitories.
Railings The dimensions and the construction of the railing should be in accordance with NFPA requirement.
In public areas vertical or closed rails shall be used to prevent children from climbing the rails.
Material: Plaster, yellow sandstone, steel
RAL 8014 Sepia brown RAL 1002 Sand yellow
Admin No. 573 Building No. 540 (preferred) Example: Emergency Stairs
1.5.4 Emergency Stairs
Exit stairs must meet all NFPA construction and material requirements and standards.
Minimum width of stairs should be 1,12 m.
The stair should have a comfortable pitch ratio of 2 x riser height + 1 tread width = 63.
Stair finishes must be slip-retardant coated or surfaces.
Material: Concrete, plaster, steel
RAL 8014 Sepia brown
Windows/Doors 1.6
Architectural Compatibility Standard for Ramstein Air Base 31
1.6.1 Application Matrix
DISTRICTS
FRAME
MATERIAL
FRAME
COLOR
PANEEL/
MIRRORED GLASS
EXTERNAL
WINDOW SILL
(with anti-hum coat) Administrative Buildings Aluminum in frame color
Dormitory Buildings Aluminum Yellow sandstone;
Concrete or aluminum in frame color
Lodging (Hotel) Buildings Aluminum, PVC Yellow sandstone;
Aluminum in frame color
Community Service Buildings
Red sandstone;
Aluminum in frame color
Parking Garage Utility Buildings
Aluminum, steel
RAL 8014 Sepia brown
Frame- or façade color
Aluminum in frame color
FRAME
MATERIAL
FRAME
COLOR PANEEL
EXTERNAL
WINDOW SILL
(with anti-hum coat) Administrative Buildings Industrial Buildings Parking Garage Utility Buildings
Aluminum, steel RAL 8014 Sepia brown
FRAME
MATERIAL
FRAME
COLOR PANEEL
EXTERNAL
WINDOW SILL
(with anti-hum coat)
Dormitory Buildings Aluminum
Family Housing Buildings PVC/aluminum
Outside:
Inside:
RAL 9016 Traffic white
Parking Garage Utility Buildings
Aluminum RAL 8014 Sepia brown
Yellow sandstone;
Concrete or aluminum in frame color
FRAME
MATERIAL
FRAME
COLOR PANEEL
EXTERNAL
WINDOW SILL
(with anti-hum coat) Administrative Buildings Community Service Buildings
Red sandstone Aluminum in frame color
Parking Garage
Utility Buildings
Aluminum RAL 8014 Sepia brown
FRAME
MATERIAL
FRAME
COLOR PANEEL EXTERNAL
WINDOW SILL
Administrative Buildings Community Service Buildings Industrial Buildings
Parking Garage
Utility Buildings
Aluminum, steel RAL 9006 White alu RAL 7022 Umbra gray
Architectural Compatibility Standard for Ramstein Air Base 32
1.6.2 General Information
Standard window/door elements should be thermally insulated plastic, stainless steel or aluminum.
The overall window and door assemblies must meet Anti-Terrorism Force Protection and NFPA requirements.
Window frame colors can differ between interior and exterior, however this is not a standard practice across RAB.
Example: Building No. 1001
Example: Doors, Steel
1.6.3 Doors
Standard door elements should be thermally insulated plastic, stainless steel or aluminum.
The door assemblies must be officially licensed/certified as fire-rated.
Door leaves, hardware, connections and locks should be selected based upon specific requirements (e.g. sound insulation, smoke and fire protection).
Hardware Hardware selection for doors must be based on building district, type, prominence and expected usage. Material: Steel, aluminum, PVC
Color: RAL 8014 Sepia brown RAL 7016 Anthracite
RAL 9016 Traffic white(Inside)
Example: Window, Steel Example: Window, PVC
Example: Window, Alu Example: Sill, , Aluminum
1.6.4 Windows
Windows should be of plastic or aluminum construction with FCKW-free core insulation. They should be provided as flush frame construction with turn/tilt hardware.
Windows must meet German (EnEV) and US energy conservation regulations and sound insulation requirements.
Hardware Hardware selection for windows must be based on building district, type, prominence and expected usage.
Window Sills New Buildings:
Aluminum, prefabricated concrete, plastic and natural stone are various types of exterior window sill materials. The selection of the window sill type depends on the appearance of the planned facade and should match the surrounding buildings.
Renovation Projects:
Aluminum should always be used for renovation projects due to low assembly requirements. In cases of brick masonry or concrete facades, bricks or other window sill material is acceptable only, if the new sill will match the existing conditions.
Security/Bullet Proof Laminates The safety of certain building groups is of special importance.
Windows in these buildings should be protected against manual and ballistic attacks.
Instead of insulating glass panes aluminized glass panes or panels may be used in the area of landing and ceiling constructions.
Material: Steel, aluminum, PVC
RAL 7016 Anthracite
RAL 9016 Traffic white(inside)
Architectural Compatibility Standard for Ramstein Air Base 33
Enlisted Club No. 2140 Example: Solar Protection
Example: Roll-down Shutter
1.6.5 Roll-down Shutters, Venetian Blinds
Solar Protection Exterior solar protection should be provided for all buildings.
The following systems are recommended for the different building functions:
Electrically-operated venetian blinds:
→ All districts, except family housing district to administrative buildings
Manually-operated roll-down shutters:
→ Community and family housing districts to dormitory buildings:
Electrically-operated roll-down shutters and tinted solar glass is recommended on the south and west side:
→ Family housing district to family housing building:
Modern office buildings have gratings for solar protection, which can also be used as fire escape route. This could be a consideration for the design of new office buildings on the base.
Guide rails as well as Venetian blind boxes same color shade as window frames. Deviating from the above, the armored shutter shell may also be provided in standard color gray of manufactory’s series.
Exterior sunshade assemblies (guide rails, sunshades) should be the same color as the window frames.
Material: Steel, Aluminum, PVC
Entry Components 1.7
Architectural Compatibility Standard for Ramstein Air Base 35
1.7.1 Application Matrix
DISTRICTS
MATERIAL COLOR
Administrative Buildings Aluminum, steel, glass
Plaster facade Red sandstone
RAL 080 8010 Beige RAL 8014Sepia brown RAL 7016 Anthracite
Dormitory Buildings
Lodging (Hotel) Buildings Aluminum, steel, glass
Plaster façade
RAL 080 8010 Beige RAL 8014Sepia brown RAL 7016 Anthracite
Community Service Buildings
Aluminum, steel, glass Expo. masonry facade
Plaster facade Red sandstone
RAL 080 8010 Beige RAL 8014Sepia brown RAL 7016 Anthracite
Parking Garage N/A Utility Buildings N/A
MATERIAL COLOR
Administrative Buildings Industrial Buildings
Aluminum, steel, glass Plaster façade
RAL 080 8010 Beige RAL 8014Sepia brown
MATERIAL COLOR
Dormitory Buildings
Family Housing Buildings Aluminum, steel, glass
Plaster façade Yellow sandstone
RAL 080 8010 Beige RAL 8014Sepia brown RAL 1002 Sand yellow
MATERIAL COLOR
Administrative Buildings Community Service Buildings
Aluminum, steel, glass Plaster facade
Red sandstone RAL 080 8010 Beige RAL 8014Sepia brown
MATERIAL COLOR
Administrative Buildings Community Service Buildings Industrial Buildings
Aluminum, steel Plaster facade
Galvanized RAL 9006 White alu RAL 7022 Umbra gray RAL 7035 Light gray
Entry Components 1.7
Architectural Compatibility Standard for Ramstein Air Base 36
1.7.2 General Information
Building entries present the first impression of a building and are major visible elements that effect the whole exterior composition of a building. They should can also serve as weather protection and waiting areas.
Note: The entrance of each building shall be provided with weather protection.
Hercules Theater No. 2101
Enlisted Club Building No.2140 Example: Entry Components
1.7.3 Entry Components
The entry components should secure the entry of a building.
Building entry components are divided in different types:
• canopy
• canopy with side wall
• vestibule, closed
• vestibule, closed with canopy
Door Closers and Panic Hardware All entrance doors should be provided with the appropriate door closers depending on door location and type.
Lockable doors in emergency exit routes must have push handles with panic hardware.
Material: Aluminum, steel, glass, plaster, sandstone red/yellow, expo. masonry Color: RAL 8014 Sepia brown , RAL 080 8010 Beige RAL 7016 Anthracite , RAL 1002 Sand yellow
RAL 9006 White alu
RAL 7022 Umbra gray
Others 1.8
Architectural Compatibility Standard for Ramstein Air Base 37
1.8.1 Application Matrix
EXTERIOR SIGNAGE ENTRANCE LIGHTING COMMUNITY
DISTRICTS MATERIAL COLOR MATERIAL COLOR
Administrative Buildings Building number painted Metal-plated numbers Free-standing sign
Dormitory Buildings Building number painted Free-standing sign
Lodging (Hotel) Buildings Community Service Buildings wall-mounted lighting canopy ceiling lighting
Parking Garage Utility Buildings
Building number painted Metal-plated numbers Free-standing sign
Number color:
Shadow color:
Wall/plaque color:
wall-mounted lighting
EXTERIOR SIGNAGE ENTRANCE LIGHTING INDUSTRIAL
Administrative Buildings Industrial Buildings wall-mounted lighting canopy ceiling lighting
Parking Garage
Utility Buildings
Building number painted Metal-plated numbers Free-standing sign wall-mounted lighting
EXTERIOR SIGNAGE ENTRANCE LIGHTING FAMILY HOUSING
Dormitory Buildings
Family Housing Buildings wall-mounted lighting canopy ceiling lighting
Parking Garage
Utility Buildings
Building number painted Free-standing sign wall-mounted lighting
RAL 9016Traffic white
EXTERIOR SIGNAGE ENTRANCE LIGHTING ADMINISTRATIVE
Administrative Buildings Community Service Buildings
Building number painted Metal-plated numbers Free-standing sign wall-mounted lighting canopy ceiling lighting
Parking Garage Building number painted Metal-plated numbers Free-standing sign
Utility Buildings Building number painted Free-standing sign wall-mounted lighting
EXTERIOR SIGNAGE ENTRANCE LIGHTING WEST END FLIGHT-
Administrative Buildings Community Service Buildings Industrial Buildings wall-mounted lighting canopy ceiling lighting
Parking Garage Utility Buildings
Building number painted Metal-plated numbers Free-standing sign wall-mounted lighting
RAL 9006 White alu
Architectural Compatibility Standard for Ramstein Air Base 38
1.8.2 General Information
Exterior signage and exterior lighting are in a relation. The signs should be placed where they can be clearly seen by the user. The exterior lighting secure the visibility at night.
Administrative No 573
Standard: Placement Building Number
Example: Building Identification Sign
Enlisted Club No 2140 (community service building) Example: Brass Building Identification Sign
Administrative Building No 573
Standard: Building Number
1.8.3 Exterior Signage
Various types of information are required to identify a building, such as building numbers (Type B5) and building functions (Type B4).
Detail information see Section 3.5.5 Identification Signs Page 100.
Building Identification Sign, Type B4 The building function is generally shown on a free-standing sign on the landscaped strip in front of the buildings. However, many buildings do not have a planting strip to accommodate a free standing sign. In this case the information should be painted or directly mounted on to the facades. Painted on signage is acceptable where no building functional changes are expected. Information on plaques for administrative buildings are recommended. Plaques can be exchanged and taken to the next building to be mounted.
Family Housing Area Signage Each family housing building should be identified by two (2) building numbers located near the outer corners facing the roadway and directly around the corner on the gable facades. Depending upon the number of entries each family housing unit entry should be identified by a letter A, B, C, D, ...
If the main entrance faces the street, an additional sign should be placed on the side of the building.
The standard entry sign for basement entries - white letters on standard brown background should be used.
For more sign standard information see Air Force Pamphlet
AFPAM 32-1097
Building Number Type B5 Each building should be identified by a building number directly painted or mounted on the corner of the street facade.
Building numbers should be at the street side on each corners of the building and entry signage at building entries with exterior lighting for visibility at night for proper destination see sketch.
Signage in housing and admin districts shall be placed at eye level (bottom edge = 1.50 m).
Signage in industrial district shall be placed height than eye level.
Type of Building Numbering Their are two-types of building numbers used on the base:
painted-on numbers:
→ for all plaster facades, except community service buildings brass numbers on plaques:
→ community service buildings and buildings with texture finishes (concrete, metal or masonry facades)
Building Number Typography: Helvetica medium, 2’’ (50mm) Height: app. 240 mm (280mm including shadow) Font size: app. 50mm;
Shadow size: app. 30mm.
Open space between numbers and shadow is not required. The space between each figure shall be appropriate. Ensure that the numbers are in line; superscript and subscript are unacceptable.
Material: Painted Wall/plaque Color:RAL 080 8010 Beige RAL 7035 Light gray Number Color: RAL 8014 Sepia Brown RAL 7019 Anthracite Shadow Color: RAL 7022 Umbra Gray RAL 7022 Umbra gray
Architectural Compatibility Standard for Ramstein Air Base 39
Building No.
Example: Entrance Lighting
Enlisted Club No.2140
1.8.4 Exterior Lighting
Standard Building Entrance Lighting Standard exterior entrance lighting fixtures should be suitable for the particular building functions and characteristics. Canopies should have ceiling mounted or recessed downlights for general lighting.
Additional wall-mounted lighting fixtures should be provided for building numbers as well as for highlighting designated features, information boards or signs.
Access stairs and ramps to entrances should be provided with wall mounted or recessed orientation lighting fixtures.
Special Building Entrance Lighting Community service buildings on the base should have appropriate building exterior lighting fixtures corresponding to the function and level of importance of the facility.
While these cannot all be defined here, examples of such buildings:
→ Headquarters USAFE Building 201 → the 86th Airlift Wing Building 2201 → the Officers Club Building 302 → the Chapel Buildings 1201
Standard…