CZQZ160015-03-A101-Floor_Plan.pdf
PDF 140 KB Posted
- Attached to
- Repair Storm Damage Building 2379 Federal contract opportunity
- Solicitation number
- FA4855-16-B-0018
About this file
Floor Plan
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FA4855-16-B-0018-0002.docx | DOCX document | |
| FA4855-16-B-0014-0002.docx | DOCX document | |
| SOW-_CZQZ16-0015_Repair_Storm_Damage_B2379.docx | DOCX document | |
| Pre-Bid_Response.doc | DOC document | |
| CZQZ160015-10-E101-Proposed_Elec.pdf | ||
| SOMS_Building_2379_Storm_Damage | — | |
| Additional_Spec.pdf | ||
| CZQZ160015-04-A102-Roof_Plan.pdf | ||
| CZQZ160015-05-A201-Elevation_Plan.pdf | ||
| Attachment_9_CAFB_Electrical_Standards-2016.pdf | ||
| Attachment_8_CAFB_Labeling_Standards__2009_Rev1.pptx | PPTX presentation | |
| Attachment_6_CAFB_Hardware_Specifications_Guideline-_2011.pdf | ||
| FA4855-16-B-0018-0001.pdf | ||
| Attachment_5_CAFB_Architectural_Compatibility_Guide-2012.pdf | ||
| Attachment_7_CAFBI32_201_Fire_Protection_Operations_N_Fire_Prevention_Program.pdf | ||
| FA4855-16-B-0018_Solicitation.pdf | ||
| Attachment_4_SOMS.pdf | ||
| Attachment_3_Drawings.pdf | ||
| Attachment_2_Specs.pdf | ||
| Attachment_1_SOW.pdf |
Show all 20
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MAINTENANCE BAY
STORAGE
STORAGE
OFFICE
OFFICE
BREAKROOM
MECHANICAL/
ELECTRICAL
STORAGE
MENS
WOMENS
COMM
73'-8"
22'-4"19'-3" 4'-3"
16'-2" 12'-2" 12'-7"
11'-9" 11'-1"
12'-11"11'-1"17'-3"
52'-4"
14'-4"
17'-4"
18'-8"
9'-2"
9'-2"
12'-8"
8'-6"
8'-6"
4'-4"
25'-2"
51'-0"
CA
NN
ON
A
FB
, N
EW
M
EX
IC
O
CI
VIL
E
NG
IN
EE
RIN
G
SQ
UA
DR
ON
OP
27 SOW
SP
27th
IAL
EC
W
IN
G
ERATION
SEQUENCE NO.
RE
VIS
IO
NS
DC HGFEA B
DC HGFEA B
OF
CA
NN
ON
A
IR
FO
RC
E
BA
SE
. C
LO
VIS
, C
UR
RY
C
OU
NT
Y, N
EW
M
EX
IC
O
SHEET NO.
S
PE
CI
AL
O
PE
RA
TI
ON
S
PR
OJ
EC
T
NU
MB
ER
CO
NC
EP
T
BY
DR
AW
N
BY
RE
VIE
WE
D
BY
RE
V
SY
MB
OL
CO
MM
EN
T
DE
SC
RIP
TIO
N
DA
TE
DA
TE
AP
PR
NO
T
FO
R
CO
NS
TR
UC
TI
ON
03 11
A-101
RP
R
ST
OR
M
DA
MA
GE
IN
Ju ly
AY
SO
N
AY
SO
N
CZ
QZ
FL
O
O R
P
LA
N
RP
A
LR
E
FA
CI
LIT
Y, B
KEYED NOTES
REMOVE EXISTING CARPET IN ROOM 104 AND 105. PREP FLOOR
SURFACE FOR NEW VINYL COMPOSITION TILE. INSTALL VINYL
COMPOSITION TILE THAT MEETS PROJECT SPECIFICATION AND
THAT HAS BEEN APPROVED BY THE GOVERNMENT. REPLACE
BASE BOARDS IN BOTH ROOMS.
REMOVE AND REPLACE ALL VINYL INSULATION IN
MAINTENANCE BAY (ROOM 101). NEW VINYL INSULATION SHALL
BE RATED R-30 AND SHALL THE APPROPRIATE AMOUNT OF
SUPPORT STEEL BANDS TO SECURE IN PLACE.
REMOVE AND REPLACE WATER DAMAGED 2'X2' CEILING TILES.
ANY SURPLUS OF CEILING TILES SHALL BE TURNED OVER TO
THE GOVERNMENT AT THE COMPLETION OF THE PROJECT.
INSTALL NEW 2'X2' CEILING GRID SYSTEM IN ROOM 107. INSTALL
NEW R-30 INSULATION OVER CEILING TILES. EXTEND EXISTING
SUPPLY DUCTING TO NEW GRID MOUNTED DIFFUSER. REMOVE
AND REINSTALL EXISTING LIGHT FIXTURE. REMOVE EXISTING
WOODEN DOOR AND REPLACE WITH NEW WOODEN DOOR WITH
LOUVER.
REMOVE AND REPLACE ALL METAL THRESHOLD AND
WEATHER-STRIPPING ON ALL EXTERIOR PERSONNEL DOORS.
REMOVE AND REPLACE EXISTING DOOR AND REPLACE WITH
NEW.
REMOVE AND REPLACE BOTH INTERIOR AND EXTERIOR
WEATHER-STRIPPING ON OVERHEAD ROLL-UP DOORS. TWO (2)
ROLL-UP DOORS TOTAL.
REMOVE AND REPLACE EXISTING HOT WATER HEATER WITH A
GOVERNMENT APPROVED COMPARABLE REPLACEMENT.
RETURN EXISTING HOT WATER HEATER OVER TO THE
GOVERNMENT.
1 1
3 3
3 3
5 6
5 5
Re vi ew ed a nd e di te d by
L t J es so p on
Ju ly
| Model |
| LOCATION PLAN |
File details come from the government source that posted it. Updated .