CZQZ160015-03-A101-Floor_Plan.pdf

PDF 140 KB Posted

Attached to
Repair Storm Damage Building 2379 Federal contract opportunity
Solicitation number
FA4855-16-B-0018
Issued by
Department of the Air Force Special Operations Command

About this file

Floor Plan

View the file

Other files for this federal contract opportunity

Other files attached to Repair Storm Damage Building 2379, newest first.
File Type Posted
FA4855-16-B-0018-0002.docx DOCX document
FA4855-16-B-0014-0002.docx DOCX document
SOW-_CZQZ16-0015_Repair_Storm_Damage_B2379.docx DOCX document
Pre-Bid_Response.doc DOC document
CZQZ160015-10-E101-Proposed_Elec.pdf PDF
SOMS_Building_2379_Storm_Damage —
Additional_Spec.pdf PDF
CZQZ160015-04-A102-Roof_Plan.pdf PDF
CZQZ160015-05-A201-Elevation_Plan.pdf PDF
Attachment_9_CAFB_Electrical_Standards-2016.pdf PDF
Attachment_8_CAFB_Labeling_Standards__2009_Rev1.pptx PPTX presentation
Attachment_6_CAFB_Hardware_Specifications_Guideline-_2011.pdf PDF
FA4855-16-B-0018-0001.pdf PDF
Attachment_5_CAFB_Architectural_Compatibility_Guide-2012.pdf PDF
Attachment_7_CAFBI32_201_Fire_Protection_Operations_N_Fire_Prevention_Program.pdf PDF
FA4855-16-B-0018_Solicitation.pdf PDF
Attachment_4_SOMS.pdf PDF
Attachment_3_Drawings.pdf PDF
Attachment_2_Specs.pdf PDF
Attachment_1_SOW.pdf PDF
Show all 20

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MAINTENANCE BAY

STORAGE

STORAGE

OFFICE

OFFICE

BREAKROOM

MECHANICAL/

ELECTRICAL

STORAGE

MENS

WOMENS

COMM

73'-8"

22'-4"19'-3" 4'-3"

16'-2" 12'-2" 12'-7"

11'-9" 11'-1"

12'-11"11'-1"17'-3"

52'-4"

14'-4"

17'-4"

18'-8"

9'-2"

9'-2"

12'-8"

8'-6"

8'-6"

4'-4"

25'-2"

51'-0"

CA

NN

ON

A

FB

, N

EW

M

EX

IC

O

CI

VIL

E

NG

IN

EE

RIN

G

SQ

UA

DR

ON

OP

27 SOW

SP

27th

IAL

EC

W

IN

G

ERATION

SEQUENCE NO.

RE

VIS

IO

NS

DC HGFEA B

DC HGFEA B

OF

CA

NN

ON

A

IR

FO

RC

E

BA

SE

. C

LO

VIS

, C

UR

RY

C

OU

NT

Y, N

EW

M

EX

IC

O

SHEET NO.

S

PE

CI

AL

O

PE

RA

TI

ON

S

PR

OJ

EC

T

NU

MB

ER

CO

NC

EP

T

BY

DR

AW

N

BY

RE

VIE

WE

D

BY

RE

V

SY

MB

OL

CO

MM

EN

T

DE

SC

RIP

TIO

N

DA

TE

DA

TE

AP

PR

NO

T

FO

R

CO

NS

TR

UC

TI

ON

03 11

A-101

RP

R

ST

OR

M

DA

MA

GE

IN

Ju ly

AY

SO

N

AY

SO

N

CZ

QZ

FL

O

O R

P

LA

N

RP

A

LR

E

FA

CI

LIT

Y, B

KEYED NOTES

REMOVE EXISTING CARPET IN ROOM 104 AND 105. PREP FLOOR

SURFACE FOR NEW VINYL COMPOSITION TILE. INSTALL VINYL

COMPOSITION TILE THAT MEETS PROJECT SPECIFICATION AND

THAT HAS BEEN APPROVED BY THE GOVERNMENT. REPLACE

BASE BOARDS IN BOTH ROOMS.

REMOVE AND REPLACE ALL VINYL INSULATION IN

MAINTENANCE BAY (ROOM 101). NEW VINYL INSULATION SHALL

BE RATED R-30 AND SHALL THE APPROPRIATE AMOUNT OF

SUPPORT STEEL BANDS TO SECURE IN PLACE.

REMOVE AND REPLACE WATER DAMAGED 2'X2' CEILING TILES.

ANY SURPLUS OF CEILING TILES SHALL BE TURNED OVER TO

THE GOVERNMENT AT THE COMPLETION OF THE PROJECT.

INSTALL NEW 2'X2' CEILING GRID SYSTEM IN ROOM 107. INSTALL

NEW R-30 INSULATION OVER CEILING TILES. EXTEND EXISTING

SUPPLY DUCTING TO NEW GRID MOUNTED DIFFUSER. REMOVE

AND REINSTALL EXISTING LIGHT FIXTURE. REMOVE EXISTING

WOODEN DOOR AND REPLACE WITH NEW WOODEN DOOR WITH

LOUVER.

REMOVE AND REPLACE ALL METAL THRESHOLD AND

WEATHER-STRIPPING ON ALL EXTERIOR PERSONNEL DOORS.

REMOVE AND REPLACE EXISTING DOOR AND REPLACE WITH

NEW.

REMOVE AND REPLACE BOTH INTERIOR AND EXTERIOR

WEATHER-STRIPPING ON OVERHEAD ROLL-UP DOORS. TWO (2)

ROLL-UP DOORS TOTAL.

REMOVE AND REPLACE EXISTING HOT WATER HEATER WITH A

GOVERNMENT APPROVED COMPARABLE REPLACEMENT.

RETURN EXISTING HOT WATER HEATER OVER TO THE

GOVERNMENT.

1 1

3 3

3 3

5 6

5 5

Re vi ew ed a nd e di te d by

L t J es so p on

Ju ly

Model
LOCATION PLAN

File details come from the government source that posted it. Updated .