Attachment_4_SOMS.pdf

PDF 539 KB Posted

Attached to
Repair Storm Damage Building 2379 Federal contract opportunity
Solicitation number
FA4855-16-B-0018
Issued by
Department of the Air Force Special Operations Command

About this file

Attachment 4 Schedule of Material Submittals

View the file

Other files for this federal contract opportunity

Other files attached to Repair Storm Damage Building 2379, newest first.
File Type Posted
FA4855-16-B-0018-0002.docx DOCX document
FA4855-16-B-0014-0002.docx DOCX document
CZQZ160015-10-E101-Proposed_Elec.pdf PDF
CZQZ160015-03-A101-Floor_Plan.pdf PDF
SOMS_Building_2379_Storm_Damage —
SOW-_CZQZ16-0015_Repair_Storm_Damage_B2379.docx DOCX document
Pre-Bid_Response.doc DOC document
Additional_Spec.pdf PDF
CZQZ160015-04-A102-Roof_Plan.pdf PDF
CZQZ160015-05-A201-Elevation_Plan.pdf PDF
Attachment_9_CAFB_Electrical_Standards-2016.pdf PDF
Attachment_8_CAFB_Labeling_Standards__2009_Rev1.pptx PPTX presentation
FA4855-16-B-0018-0001.pdf PDF
Attachment_5_CAFB_Architectural_Compatibility_Guide-2012.pdf PDF
Attachment_7_CAFBI32_201_Fire_Protection_Operations_N_Fire_Prevention_Program.pdf PDF
Attachment_6_CAFB_Hardware_Specifications_Guideline-_2011.pdf PDF
FA4855-16-B-0018_Solicitation.pdf PDF
Attachment_3_Drawings.pdf PDF
Attachment_2_Specs.pdf PDF
Attachment_1_SOW.pdf PDF
Show all 20

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TO BE COMPLETED BY CONTRACT ADMINISTRATOR

L I N E

N U M B E R

ITEM, DESCRIPTION OF ITEM,

CONTRACT REFERENCE,

TYPE OF SUBMITTAL

C

ER

TI

F

O F

C O

M

PL

IA

N

C E

SH

O

P D

R A

W

IN

G S

SA

M

PL

ES

C

O

LO

R S

EL

EC

T

TE

ST

R

ES

U

LT

S

M A

N F'

R R

EC

O

M M

EN

D

A

TI

O N

S

M A

N F'

R . W

A R

R A

N

TY

LI

C

EN

SE

D A

PP

LI

C A

TO

R

M A

N U

F' S

TE

C

H N

IC

A

L D

A

TA

EL

EC

TR

O

N

IC

F

IL

ES

(C

D

O

TH

ER

R

EQ

U

IR

ED

SU

B M

IS

SI

O N

D A

TE

D A

TE

R

EC

EI

VE

D

IN

C

O N

TR

A

C

TI

N G

D A

TE

T

O

IV

IL

E

N G

IN

EE

R

IN

G

R

ET

U R

N S

U

SP

EN

SE

D A

TE

FO

LL

O W

-U P

C O

N

TR

A C

TO

R

N O

TI

FI

A pp ro va l D at e

C O

N

TR

A C

TO

R

N O

TI

FI

ED

D is

A pp ro va l D at e

C O

N

TR

A C

TO

R

E-

SU

B M

IT

TA

L

FI

N

A L

A

PP

R O

VA

L

R

EM

A R

K S

Statement of Work §5 Meetings:

Preconstruction Meeting Minutes

1 3 5 working days after meeting is held

Statement of Work §5 Meetings: Post Survey Briefing

1 3 5 working days after meeting is held

Statement of Work (SOW) §21.1 Constrution Schedule AF Form 3064

1 2 5 working days after meeting is held

SECTION 01 01 00 Work §1.3 C. Clearance Request AF 103

1 3 10 working days prior to start of Construction

5 SECTION 01 11 00 §1.4 Salvage Plan 1 3 10 working days prior to start of Construction

6 SECTION 01 30 00 §1.3 View Location Map 1 3 10 working days prior to start of Construction

SECTION 01 30 00 §1.4 Progress and Completion Pictures

1 3 Weekly, Throughout the Duration of the Project

SECTION 01 30 00 §1.7.2 Superintendent Qualifications

1 3 10 working days after

Notice to proceed (NTP)

SECTION 01 35 26 §1.7 Accident Prevention Plan (APP)

1 3 15 working days prior to the date of Pre- Construction Meeting

SECTION 01 35 26 §1.12.2 Accident Reports

1 3 NLT 5 working days after accident/near misses

SECTION 01 35 40.00 20 §1.8

Environmental Protection Plan (EPP)

1 3 10 working days after

Notice to proceed (NTP)

SECTION 01 35 40.00 20 §3.3 Field Quality Control Reports

1 3 10 working days prior to start of Construction

SECTION 01 35 40.00 20 §1.7 Material Safety Data Sheets (MSDS)

1 3 10 working days prior to bring material on base

SECTION 01 43 00 §1.1 Traffic Control for Airfield Safety

1 3 15 working days after

Notice to proceed (NTP)

SECTION 01 45 00.00 10 §3.2 Contractor Quality Control Plan

5 working days after Notice to proceed (NTP)

SECTION 01 74 19 §1.6 Waste Management Plan

1 3 10 working days after

Notice to proceed (NTP)

17 SECTION 01 78 00 §3.1 As-built Drawings 1 3 20 working days after the completion of construction

NUMBER OF COPIES REQUIRED

AF FORM 66 SCHEDULE OF MATERIALS SUBMITTALS

PROJECT # PROJECT TITLE SOLICITATION/CONTRACT NO.

CZQZ16-0015

Repair Storm Damage

B2379

TO BE COMPLETED BY PROJECT ENGINEER

FA4855-16-B-0018 Attachment 4

I N E

N U M B E R

ITEM, DESCRIPTION OF ITEM,

CONTRACT REFERENCE,

TYPE OF SUBMITTAL

C

ER

TI

F

O F

C O

M

PL

IA

N

C E

SH

O

P D

R A

W

IN

G S

SA

M

PL

ES

C

O

LO

R S

EL

EC

T

TE

ST

R

ES

U

LT

S

M A

N F'

R R

EC

O

M M

EN

D

A

TI

O N

S

M A

N F'

R . W

A R

R A

N

TY

LI

C

EN

SE

D A

PP

LI

C A

TO

R

M A

N U

F' S

TE

C

H N

IC

A

L D

A

TA

EL

EC

TR

O

N

IC

F

IL

ES

(C

D

O

TH

ER

R

EQ

U

M

IS

SI

O N

D A

TE

D A

TE

R

EC

EI

O N

TR

A

C

TI

N G

D A

TE

IL

E

N G

IN

EE

R

IN

G

R

ET

U R

N S

U

SP

EN

SE

D A

TE

FO

LL

O W

-U P

C O

N

TR

A C

TO

R

N O

TI

FI

ro va l D at e

C O

N

TR

A C

TO

R

N O

TI

FI

ED

D is

A pp ro va l D at e

C O

N

TR

A C

SU

B M

IT

TA

L

FI

N

A L

A

PP

R O

VA

L

R

EM

A R

K S

NUMBER OF COPIES REQUIRED

AF FORM 66 SCHEDULE OF MATERIALS SUBMITTALS

PROJECT # PROJECT TITLE SOLICITATION/CONTRACT NO.

CZQZ16-0015

18 SECTION 02 41 00 §1.2.1 Demolition Plan 1 3 15 working days prior to start of Construction

SECTION 02 41 00 §1.10 Existing Conditions

1 3 15 working days prior to start of Construction

SECTION 02 41 00 §1.6 Demolition Notification

1 3 5 working days prior to start of Construction

SECTION 07 60 00 §1.3 Flashing Shop drawing and manufacture information (gutters, downspouts, base flashing, flashing at penetrations, drip edge eave flashing

3 3 1 3 10 working days prior to use of material

22 SECTION 07 92 00 §2.1 Sealants 3 3 3 1 3 10 working days prior to use of material

SECTION 08 11 13 §2.1 Metal Door and Frame

3 3 3 3 1 3 10 working days prior to use of material

SECTION 08 91 00 §2.2- 2.3 Wall and Door Louvers

3 1 3 10 working days prior to use of material

25 SECTION 09 30 13 §2.1 Tile 3 3 3 3 10 working days prior to use of material

26 SECTION 09 30 13 §2.2- 2.3 Setting-BedTile 3 3 3 3 10 working days prior to use of material

SECTION 09 30 13 §2.2- 2.3 Mortar, Grout and Adhesive

3 3 3 3 10 working days prior to use of material

28 SECTION 09 51 00 §1.3 Shop Drawing 3 1 3 10 working days prior to use of material

SECTION 09 51 00 §2.1 Acoustical Ceiling System and Ceiling Tiles

3 3 3 3 10 working days prior to use of material

30 SECTION 09 65 00 §2.1 VCT TILES 3 3 3 1

10 working days prior to use of material

31 SECTION 09 90 00 §1.3 Coating and Color 1 3 10 working days prior to use of material

32 SECTION 23 00 00 §1.3 Air Handling Unit 3 3 3 3 10 working days prior to use of material

SECTION 23 00 00 §1.3 Room Fan-Coil Units

3 3 3 3 10 working days prior to use of material

34 SECTION 23 00 00 §1.3 Metal Ducts 3 3 3 3 10 working days prior to use of material

SECTION 23 00 00 §1.3 Supply Diffusers and Returns

3 3 3 3 10 working days prior to use of material

SECTION 23 07 00 §1.3 Duct and Pipe Insulation System

3 3 3 3 10 working days prior to use of material

SECTION 23 11 25 §1.3 Gas Pipe and Fittings

3 3 3 3 10 working days prior to use of material

I N E

N U M B E R

ITEM, DESCRIPTION OF ITEM,

CONTRACT REFERENCE,

TYPE OF SUBMITTAL

C

ER

TI

F

O F

C O

M

PL

IA

N

C E

SH

O

P D

R A

W

IN

G S

SA

M

PL

ES

C

O

LO

R S

EL

EC

T

TE

ST

R

ES

U

LT

S

M A

N F'

R R

EC

O

M M

EN

D

A

TI

O N

S

M A

N F'

R . W

A R

R A

N

TY

LI

C

EN

SE

D A

PP

LI

C A

TO

R

M A

N U

F' S

TE

C

H N

IC

A

L D

A

TA

EL

EC

TR

O

N

IC

F

IL

ES

(C

D

O

TH

ER

R

EQ

U

M

IS

SI

O N

D A

TE

D A

TE

R

EC

EI

O N

TR

A

C

TI

N G

D A

TE

IL

E

N G

IN

EE

R

IN

G

R

ET

U R

N S

U

SP

EN

SE

D A

TE

FO

LL

O W

-U P

C O

N

TR

A C

TO

R

N O

TI

FI

ro va l D at e

C O

N

TR

A C

TO

R

N O

TI

FI

ED

D is

A pp ro va l D at e

C O

N

TR

A C

SU

B M

IT

TA

L

FI

N

A L

A

PP

R O

VA

L

R

EM

A R

K S

NUMBER OF COPIES REQUIRED

AF FORM 66 SCHEDULE OF MATERIALS SUBMITTALS

PROJECT # PROJECT TITLE SOLICITATION/CONTRACT NO.

CZQZ16-0015

SECTION 23 11 25 §1.3 Welders Qualifications

1 3 10 working days prior to use of material

SECTION 23 23 00 §2.2 Refrigerant piping material

3 3 3 3 10 working days prior to use of material

SECTION 23 23 00 §3.4 Refrigerant piping testing

3 1 3 5 working days after intallation

SECTION 26 00 00.00 20 §3.4 Electrical Shop Drawings

3 1 3 10 working days after completion of work

SECTION 26 05 19.00 10 §2 Insulated Conductor wire

3 3 3 10 working days prior to use of material

SECTION 26 08 00 §1.4.3 Accepatance testing and inspection

3 1 3 10 working days after completion of work

44 SECTION 26 20 00 §2.2 Conduit Fittings 3 3 3 3 10 working days prior to use of material

45 SECTION 26 20 00 §2.11 Circuit breakers 3 3 3 3 10 working days prior to use of material

46 SECTION 26 20 00 §2.9 Switches 3 3 3 3 10 working days prior to use of material

47 SECTION 26 56 00 §1.3 Photometric plan 3 1 3 10 working days prior to use of material

SECTION 26 56 00 §2.1.3 Induction Luminaires

3 3 3 3 10 working days prior to use of material

SECTION 26 56 00 §2.1.3 Luminaire ballasts

3 3 3 3 10 working days prior to use of material

50 SECTION 26 56 00 §2.2.1 Photo Cell 3 3 3 3 10 working days prior to use of material