CZQZ160015-04-A102-Roof_Plan.pdf

PDF 132 KB Posted

Attached to
Repair Storm Damage Building 2379 Federal contract opportunity
Solicitation number
FA4855-16-B-0018
Issued by
Department of the Air Force Special Operations Command

About this file

Roof Plan

View the file

Other files for this federal contract opportunity

Other files attached to Repair Storm Damage Building 2379, newest first.
File Type Posted
FA4855-16-B-0018-0002.docx DOCX document
FA4855-16-B-0014-0002.docx DOCX document
SOW-_CZQZ16-0015_Repair_Storm_Damage_B2379.docx DOCX document
Pre-Bid_Response.doc DOC document
CZQZ160015-10-E101-Proposed_Elec.pdf PDF
CZQZ160015-03-A101-Floor_Plan.pdf PDF
SOMS_Building_2379_Storm_Damage —
Additional_Spec.pdf PDF
CZQZ160015-05-A201-Elevation_Plan.pdf PDF
Attachment_9_CAFB_Electrical_Standards-2016.pdf PDF
Attachment_8_CAFB_Labeling_Standards__2009_Rev1.pptx PPTX presentation
Attachment_6_CAFB_Hardware_Specifications_Guideline-_2011.pdf PDF
FA4855-16-B-0018-0001.pdf PDF
Attachment_5_CAFB_Architectural_Compatibility_Guide-2012.pdf PDF
Attachment_7_CAFBI32_201_Fire_Protection_Operations_N_Fire_Prevention_Program.pdf PDF
FA4855-16-B-0018_Solicitation.pdf PDF
Attachment_4_SOMS.pdf PDF
Attachment_3_Drawings.pdf PDF
Attachment_2_Specs.pdf PDF
Attachment_1_SOW.pdf PDF
Show all 20

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

73'-8"

52'-4"

CA

NN

ON

A

FB

, N

EW

M

EX

IC

O

CI

VIL

E

NG

IN

EE

RIN

G

SQ

UA

DR

ON

OP

27 SOW

SP

27th

IAL

EC

W

IN

G

ERATION

SEQUENCE NO.

RE

VIS

IO

NS

DC HGFEA B

DC HGFEA B

OF

CA

NN

ON

A

IR

FO

RC

E

BA

SE

. C

LO

VIS

, C

UR

RY

C

OU

NT

Y, N

EW

M

EX

IC

O

SHEET NO.

S

PE

CI

AL

O

PE

RA

TI

ON

S

PR

OJ

EC

T

NU

MB

ER

CO

NC

EP

T

BY

DR

AW

N

BY

RE

VIE

WE

D

BY

RE

V

SY

MB

OL

CO

MM

EN

T

DE

SC

RIP

TIO

N

DA

TE

DA

TE

AP

PR

NO

T

FO

R

CO

NS

TR

UC

TI

ON

04 11

A-102

RP

R

ST

OR

M

DA

MA

GE

IN

Ju ly

AY

SO

N

AY

SO

N

CZ

QZ

R O

O F

PL

A

N

RP

A

LR

E

FA

CI

LIT

Y, B

SCALE:1/4" = 1'-0"

ROOF PLAN1

REMOVE EXISTING RIDGE CAP AND REPLACE WITH NEW RIDGE CAP IN

ORDER TO PROVIDE COMPLETE WEATHER-TIGHT SEAL. NEW RIDGE

CAP SHALL BE 22 GAUGE AND SHALL BE INSTALLED PER

MANUFACTURE'S RECOMMENDATION.

REMOVE EXISTING RAKE FLASHING ON THE NORTH AND SOUTH END

OF THE STRUCTURE AND REPLACE WITH NEW RAKE FLASHING TO

PROVIDE A WEATHER-TIGHT SEAL. NEW RAKE FLASHING SHALL BE 22

GAUGE AND SHALL BE INSTALLED PER MANUFACTURE'S

RECOMMENDATIONS.

REPLACE EXISTING GUTTER AND DOWNSPOUT SYSTEM ON THE EAST

AND WEST ENDS OF THE STRUCTURE. GUTTER/ DOWNSPOUT SYSTEM

SHALL BE 22 GAUGE AND SHALL BE INSTALLED PER MANUFACTURE'S

RECOMMENDATION.

INSTALL DRIP EDGE FLASHING ALONG THE ENTIRE LENGTH OF THE

GUTTER SYSTEM.

REMOVE AND REPLACE EXISTING PENETRATION FLASHING TO

ACHIEVE A WEATHER-TIGHT SEAL. NEW PENETRATION FLASHING

SHALL BE SPECIFICALLY FOR METAL ROOF USE.

DIRECT NEW DOWNSPOUT TO DRAIN TOWARDS EXISTING TRENCH

DRAIN ON THE NORTH END OF THE BUILDING

KEYED NOTES

Re vi ew ed a nd e di te d by

L t J es so p on

Ju ly

Model
LOCATION PLAN

File details come from the government source that posted it. Updated .