Appendix_G_-_ACM_LBP_Specs.pdf

PDF 322 KB Posted

Attached to
Replace Chiller Pumps & Piping Bldg 4196 Federal contract opportunity
Solicitation number
FA301618R0068
Issued by
Department of the Air Force Air Education and Training Command

About this file

Appendix G - 502CES ACM LBP Spec Requirements

View the file

Other files for this federal contract opportunity

Other files attached to Replace Chiller Pumps & Piping Bldg 4196, newest first.
File Type Posted
Amendment_0003_22_Aug_18.pdf PDF
Utility_Drawings.zip ZIP file
Appendix_C_-_Conceptual_Drawings.zip ZIP file
DB_SOW_JBSF170263_Replace_Chiller_Pumps_and_Piping_B4196_Rev_1_20180816.pdf PDF
Technical_Specifications_List_Rev_20180816.pdf PDF
Amendment_0002_21_Aug_18.pdf PDF
USACE_AHU-2.jpeg JPEG file
Chiller_B4196_Model_(1).pdf PDF
WaterMain_Routing_1_of_2.jpeg JPEG file
Water_Main_Routing_2_of_2.jpeg JPEG file
Site_Visit_Q_A's_Updates_8-13-18.pdf PDF
Amendment_001.docx DOCX document
Sign-in_Sheet_30_July_18.pdf PDF
Appendix_H_-_Radioactive_Mat.pdf PDF
Appendix_J_-_AEC_CAD_StandardR5.pdf PDF
Appendix_K_Jan_2003.pdf PDF
Appendix_C_-_Mechanical_Rm_and_Cooling_Tower_2.pdf PDF
Appendix_E_-_Photos_19_July_18.pdf PDF
Appendix_L_Slide_Show__30July13_(2).pdf PDF
Appendix_F_-_Asbestos_and_Lead_Based_Paint_Survey.pdf PDF
Appendix_L_HAZMAT_Usage_Report_30July13_(1).pdf PDF
Appendix_A_-_Technical_Specs.pdf PDF
Appendix_B_-_Combined_File.pdf PDF
Appendix_I.pdf PDF
Attachment_2_-_Schedule_of_Material_Submittals_20180719.pdf PDF
Attachment_3_-_Wage_Determination_TX180280_07_06_18.pdf PDF
FA301618R0068.pdf PDF
Attachment_5_-_IMT3064_Progress_Schedule_-_19_July_18.xls XLS spreadsheet
Attachment_1_-_DB_SOW_JBSF170263-Replace_Chiller,_Pumps_and_Piping,_B4196_Rev_201805.pdf PDF
Attachment_4_-_Past_Performance_Information_Sheet_19_July_18.docx DOCX document
Show all 30

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS/ LEAD

502d CIVIL ENGINEER SQUADRON (CES}

Environmental Specifications Requirements

Site Specific Notification: (The following information must be included in all projects falling under the jurisdiction of the 502d CES).

Asbestos:

Licenses, Permits and Notification;

a. The contractor shall be responsible for completing the Department of State Health Services (DSHS) 10-day asbestos notification. Once notification package Is complete, It must be conveyed (original signature only) to (DSHS).

b. Once the DSHS notification has been completed and returned. The contractor must forward the notification to Fort Sam Houston's (FSH) Project Manager (PM). The (FSH) (PM) will then review the notification package for completeness and accuracy. The following minimum Information must be Included on Transmittal:

1. (FSH) (PM) contact information.

2. Project number.

3. Building# and address (demolition site),

4. Asbestos abatement contractor's contact Information.

c. The (FSH) (PM) will forward the notification package to the S02d Civil Engineer Squadron Environmental Offke at the following address:

S02d Ctvll Engineer Squadron Environmental Office 2250 Engineer Street, Suite 7 Fort Sam Houston, TX 78234-7740 Attn: Ms. Ingrid Rhodes

d. The notification package wlll be logged-in and routed to Mr. Leandro Quiroga (Mike)

(Asbestos and Lead Manager). If the asbestos notification package is found to be in error, the (FSH) (CES) (PM) wlll be notified that the package must be corrected and resubmitted. If the package is found to be complete and accurate, it will be signed off by the Asbestos and Lead Manager. The (FSH) (CES) (PM) will then be notified that the package Is ready for pick-up.

19 July 18

e. If start and completion dates are not met, the contractor will submit an amendment to the original state notification. The (CES/EO) wlll sign .ind the (PM) will return to the contractor.

f, The (FSH) (CES) (PM) will then forward documentation to the contractor. The contractor must deliver the signed Original asbestos notification package to DSHS In a manner, and within the time frame required by IAW TEXAS LAW

Asbestos:

Disposal Documentation;

a. The contractor shalt prepare the manifest for disposal.

b. The contractor shall prepare all waste profile documentation for the acceptance of waste into the disposal facility.

c. The profile sheet must be signed by the Fort Sam Houston (CES) Envlronmental Office

(EO).

d. The contractor shall use the FSH's Environmental Protection Agency (EPA) Identification and state registration numbers.

e. The manifest must be signed by the (FSH) (CES) Environmental personnel as the generator.

f. The manifest shall be returned to the (FSH) (CES)Environmental Office no later than 30-days after disposal materials have been shipped.

g. The original manifest must be malled to:

502d Civil Engineer Squadron

Environmental Office

2250 Engineer Street, Suite 7

Lead:

Fort Sam Houston, TX 78234•7740

h. The contractor's final clearance test results must be submitted to the (FSH) (CES) (EO) for review and approval prior to occupancy.

Disposal Documentation:

a. The contractor shall prepare the manifest for debris disposal, as required.

b. The contractor shall prepare all required waste profile documents for the disposal of waste Into the disposal facility. The profile sheets shall be signed by the Fort Sam

Houston's (CES) Environmental Office.

c. The contractor shall use (FSH)'s (EPA)'s identification and state registration numbers.

d. The manifest must be signed by (FSH) (EO) personnel as the generator.

e. The original manifest must be returned to the (FSH) (CES) (EO) no later than 30-days after material has been shipped.

f. The original manifest shall be mailed to aforementioned address mentioned above.