15._0_ANC_Building_Standards.pdf

PDF 35 KB Posted

Attached to
Bureau of Land Management (BLM) Fourth Floor Renovation Project
Solicitation number
EQ10PCB-1-18-0042
Issued by

About this file

ANC BLDG Standards

View the file

Other files

File Type Posted
SF30-AMD0003_-_FBO_-.pdf PDF
Q_and_A_Running_Log.pdf PDF
SF_30_AMEND_001.pdf PDF
1.0_4th_floor_proposed_layout-22x34.Rev0.pdf PDF
AMD_002_-_BLM_Project_-_EQ10PCB1180042.pdf PDF
SF_30_AMEND_001.pdf PDF
1.0_4th_floor_proposed_layout-22x34.Rev0.pdf PDF
22.0_SBU_Fitness_Determination_Policy_and_Procedure.pdf PDF
4.0_Mail.Copy.pdf PDF
14.0_GSA_Dust_Control_Procedures.pdf PDF
2.0_As_Builts_11x17.pdf PDF
6.0_Section_930.pdf PDF
6.5_Section_930_Close_Up.pdf PDF
0.0_AFB_BLM_4th_Floor_Renovatios_SOW.pdf PDF
Agreement.pdf PDF
10.01_BLM_Faceplate_Labeling_Example.pdf PDF
3.0_Egress_Direction_Drawing_11x17.pdf PDF
21.0_Key_Sustainable_Product.pdf PDF
SF_1442_for_sol.pdf PDF
8.0_Security_Mesh.pdf PDF
16.0_PIV_Policy_and_Guide.pdf PDF
17.0_NIST_FIPS201-2.pdf PDF
SF_1442_cont_sheet.pdf PDF
11.0_GSA_Region_10_-_Fire_Alarm_Design,_Installation_and_Testing_Policy.pdf PDF
20.0_Wage_Determination.pdf PDF
9.0_Cadastral.pdf PDF
7.0._Sound_Attenuation.pdf PDF
13.0_GSA_Region_10_-_Wet_Sprinkler_System_Guidelines.pdf PDF
19.0_Communications_Closets_Plan_Rev_1.pdf PDF
10.03_GSA_PBS-P100_2017.pdf PDF
10.02_Store_Front_Door_Example.pdf PDF
Reps_and_Certs.pdf PDF
18.0_DHS_FPS_MegaCenter_Alarm_Requirements.pdf PDF
5.0_New_Conference_Rm.pdf PDF
12.0_GSA_Region_10_-_Fire_Watch_Log.pdf PDF
Solicitation.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Federal Bldg & USCH 222 W 7th Ave

Anchorage, Alaska

Doors, Door Frames, and Hardware

Door Hardware Brand

Mod. #

Size/Style

Swing

Finish

Other Information

Hinge Sets

McKinney TA2731 4-1/2” x4-1/2” LH US26 Hinge Butts, Contract Hardware McKinney TA2731 4-1/2” x 4-1/2” RH US26 Hinge Butts, (206)298-4770 Door Locksets Sargent 8205 Mortised LH US26 Office Lock-Set, contract Hardware Sargent 8205 Mortised RH US26 Office Lock-set (206)298-4770

Door Closers

LCN 4041 Super Smoothee Series Aluminum Delay Close, McMaster # 8082A55 Sargent 350 US26

Cipher Locksets Unican/Simplex- LL1021B26D41 LH Sat.

chrome Lever Handle-Sargent Fig-8, Grainger

Unican/Simplex-LR1021B26D41 RH Sat.

chrome

Lever Handle-Sargent Fig-8, Grainger

Wall Door Stops Rockwood 406 2 1/2" dia., ¾ iprojection US26 Wall Stop with convex bumper

Wood Doors 3’-0 X 7’-0” X 1 ¾” thick Face Veneer and Edge Strips: Appalachian White Oak, rift cut.

Majority of doors have Golden Oak stain (Watco brand) with satin (Flect Varathane) finish. Doors in parts of the court area are finished with a mahogany stain.

Metal Door Frames Full welded type, channel sections with integral stops, 16 gauge, 1 ½ inch stile.

Windows (Relites)

Frames Oak, stained to match door veneers.

Glass ¼” architectural grade, tempered safety glass

Blinds 1 inch wide slats, aluminum, Hunter Douglas or Levelor brand

Finishes

Suspended Acoustical Ceilings Panels: Armstrong 772A Corega Square Lay-in (one of many styles), 24 in by 60 in by 5/8 in.

T-bar grid: 15/16” wide, color white

Paint (unless otherwise specified) Semi-gloss latex, Fed Spec color #27722 (white) Semi-gloss oil base enamel for all frames, color #27722

Carpet Tiles (usually gov’t furnished) Milliken Colorweave, Tufted, Texture Loop Pile, 36” by 36” Modular with Comfort Plus Milliken Movements, Bonded Cut Pile, 36” by 36” Modular with Comfort Plus Milliken 18” X 18” with felt backing (used for accent color) Mannington 18” X 18” with vinyl backing (used for accent color) Carpet Glue is releasable low VOC adhesive, Henrys Peach glue # 630 or as recommended by the carpet manufacturer.

Cove Base Top set premolded external corners, Type I Rubber, 4 inch height, 1/8” thick, color as specified. Acceptable manufacturers are Burke, Roppe, or FlexCo.

Mechanical

VAV Boxes Tempmaster Model s, single duct terminal unit Tempmaster Model HSW, single duct w/hot water reheat

Diffusers Titus TBD 3 series, Plenum slot diffuser, 1 inch slot width, extruded alum face, various lengths and # of slots, for use in suspended acoustical clg.

HVAC Controls Johnson Controls Inc. Metasys VAV controller: AP-VMA1420-0 T-Stat: TE-67NP-1B00 or -2B00 2-way heating valve: VG5270BC+7452G

Electrical

Light Fixtures 2X4 2-tube fluorescent fixture designed for air and heat transfer, Day-Brite Lighting Model 2DGC232-RA12-277-1/2-EB10R.

Modular Lighting System Electro/connect (brand name), factory assembly of lighting cables, lighting interface connectors, and switch boxes.

Cellular Metal Floor Raceway for Power and Communication Robertson Tapmate II System

ANC Bldg Std Glazing and Doors
ANC FB Bldg Std Finishes
ANC FB Bldg Std Mech and Elec