WATERTIGHT DOOR SYSTEM
INSTRUCTIONS AND RENEWAL PARTS SHEETS
AS SUPPLIED FOR
AGOR-24
CUSTOMER: HALTER MARINE, INC.
MOSS POINT, MISSISSIPPI
PURCHASE ORDER NUMBER: M014199
DESIGN & SALES OFFICE:
WALZ & KRENZER, INC.
. 90 FOREST A VENUE
LOCUST VALLEY, NEW YORK 11560
TELEPHONE: (516) 671-2063 FAX NO. : (516) 759-9405
SALES & MANUFACTURING OFFICE:
WALZ & KRENZER, INC.
1390 Mr. READ BOULEY ARD
ROCHESTER, NEW YORK 14606
TELEPHONE: (716) 254-6670 FAX NO.: (716) 254-6178
OCTOBER 25, 1994
WK JOB NO. 8581
15'
HYDRAULIC DOOR
TABLE OF CONTENTS
, ...-.... SECTION TITLE PAGE NO.
I GENERAL INFORMATION 4
II DESCRIPTION AND PRINCIPLES OF OPERATION 5-6
m INSTALLATION PROCEDURE 7-14
IV TEST PROCEDURE 15
v OPERA TING INSTRUCTIONS - POWER OPERA TED DOOR 16-17
VI OPERA TING INSTRUCTIONS - HAND OPERA TED DOOR 18
VII MAINTENANCE 19 - 22
VIII TROUBLE SHOOTING GUIDE 23
IX DRAWINGS - POWER OPERATED DOOR 24-32
x DRAWINGS - POWER OPERATED & HAND OPERATED 33-36
XI DRAWINGS - HAND OPERATED DOOR 37
LIST OF DRAWINGS
SECTION IX - DRAWINGS - POWER OPERATED DOOR
DRAWING NO. TITLE
D-WK-492-A81 HORIZONTAL ELECTRO-HYDRAULIC WATERTIGHT DOOR
C-WK-437-57 MOTOR PUMP
C-WK-471-44 PRESSURE SWITCH
D-WK-756-35 ELECTRICAL WIRING DIAGRAM
B-WK-723-88 WARNING HORN
B-WK-488-24 MOTOR OUTLINE DATA AND PUMP ADAPTOR
B-WK-756-23 LOCAL CONTROL SWITCH
C-WK-723-94 LIMIT SWITCH
D-WK-756-22 PILOT HOUSE STATION (2) DOOR
SECTION IX - DRAWINGS - POWER OPERATED DOOR
PAGE NO.
D-WK-492-A71
C-WK-364-4
A-WK-672-131
HYDRAULIC COMPONENTS FOR SLIDING WATERTIGHT DOOR 33
MECHANICAL INDICATOR 34
SPARE PARTS LIST, PAGES 1 & 2 OF 2 35 &36
SECTION IX- DRAWINGS - POWER OPERATED DOOR
D-WK-492-A69 HAND HYDRAULIC HORIZONTAL WATERTIGHT DOOR 37
-~ SECTION I
GENERAL INFORMATION
A. THE BASIC USE OF THIS TYPE OF DOOR IS TO SEAL OFF BULKHEADS IN CASE OF
EMERGENCY. IT HAS THE FOLLOWING CHARACTERISTICS:
POWER OPERATED DOOR
1. IT IS FLAMETIGHT AND WATERTIGHT.
2. IT CAN BE OPERATED FROM A REMOTE POSITION AND FROM LOCAL POSITIONS EACH
SIDE OF THE BULKHEAD.
3. IN CASE OF POWER FAILURE, IT CAN BE OPERATED MANUALLY FROM LOCAL POSITIONS
EACH SIDE OF THE BULKHEAD AND FROM A REMOTE POSITION ABOVE THE DOOR
4. IT CONFORMS WITH U. S. COAST GUARD REGULATIONS FOR CLASS III DOORS.
HAND OPERATED DOOR
1. IT IS FLAMETIGHT AND WA TERTIGIIT.
2. IT CAN BE OPERATED MANUALLY FROM LOCAL POSITIONS EACH SIDE OF THE
BULKHEAD AND FROM A REMOTE POSITION ABOVE THE MARGIN LINE.
3. IT CONFORMS WITH U.S. COAST GUARD REGULATIONS FOR CLASS II DOORS.
SECTION II
DESCRIPTION AND PRINCIPLES OF OPERATION
A. MECHANICAL EQUIPMENT
1. THE POWER OPERATED DOOR, PAGE 24, AND THE HAND OPERATED DOOR, PAGE 37, MOVE
IN A HORIZONTAL DIRECTION AND ARE GUIDED BY GUIDE RAIL ASSEMBLIES. THE TOP
AND BOTTOM EDGES OF THE DOOR AND FRAME ARE MACHINED TO A MATCHING TAPER
WHICH ALLOWS AUTOMATIC "SEALING OFF" OF THE CLEAR OPENING WHEN DOOR IS
CLOSED.
2. A MECHANICAL INDICATOR, PAGE 34, INDICATES THE POSITION OF THE DOOR AT THE
REMOTE MANUAL CONTROL STATION. THIS CONSISTS OF A TRANSMITTER MOUNTED AT
THE DOOR, CONNECTED TO A FLEXIBLE CABLE WIDCH IS RUN TO A RECEIVER
INDICATOR AT THE REMOTE STATION.
B. HYDRAULIC EQUIPMENT - POWER OPERA TED DOOR - REFER TO DETAIL "B" PAGE 24.
1. THE DOOR IS ACTUATED BY A HYDRAULIC CYLINDER, PRESSURE BEING SUPPLIED BY A
MOTOR DRIVEN PUMP AND, IN THE ABSENCE OF ELECTRIC POWER OR IN CASE OF
EMERGENCY, BY ROTARY HAND PUMPS.
2. THE LOCAL HAND PUMP, LOCATED BESIDE THE DOOR, IS REVERSIBLE TO PERMIT
OPENING OR CLOSING THE DOOR. IF CONDITIONS PERMIT, A SINGLE PUMP WITH DUAL
SHAFT EXIENSIONS MAY BE USED TO ALLOW OPERATION FROM EITHER SIDE OF THE
BULKHEAD.
TWO PUMPS WITH SINGLE SHAFT EXIENSION MAY BE PROVIDED IF NECESSARY. HAND
CRANKS, MOUNTED ON THE SHAFT, ALLOW THE OPERATOR TO ROTATE THE PUMP.
REVERSAL OF ROTATION REVERSES THE DIRECTION OF TRAVEL OF THE DOOR.
3. THE REMOTE HAND PUMP, LOCATED AT THE REMOTE, MANUAL CONTROL STATION, IS
UNI-DIRECTIONAL AND, IN ACCORDANCE WITH U.S.C.G. REGULATIONS, ALLOWS FOR
CLOSING OF THE DOOR ONLY.
4. THE MOTOR, PUMP AND HYDRAULIC CONTROL VALVES ARE MOUNTED ON A COMMON
BASE TO BE MOUNTED BESIDE THE DOOR.
5. A TWO GALLON OIL EXPANSION TANK IS MOUNTED ABOVE AND ADJACENT TO THE
REMOTE MANUAL PUMP. THIS MAKES UP THE DIFFERENCE IN DEMAND OF OIL WHEN
OPENING OR CLOSING THE DOOR DUE TO THE DIFFERENCE IN AREA OF THE TWO SIDES
OF THE PISTON.
6. THE AUXILIARY OIL TANK IS USED TO INSURE DOOR OPERATION IN THE EVENT OF
RUPTURE OF HYDRAULIC TANK LINE MORE THAN 10' FROM DOOR.
SECTION 11-(Continued)
DESCRIPTION AND PRINCIPLES OF OPERATION (Continued)
C. HYDRAULIC EQUIPMENT- HAND OPERATED DOOR-REFER TO DETAIL "B" PAGE 37
1. OPERATION AND ACTUATION OF THIS DOOR IS IDENTICAL TO THE POWER OP.ERATED
DOOR, PARAGRAPH B, EXCEPT THAT IT DOES NOT HA VE THE "POWER OPERA TED"
FEATURE.
D. ELEC1RIC EQUIPMENT - REFER TO DRAWING PAGE 27.
1. A REVERSING CONTROLLER ST ARTS AND STOPS THE MOTOR - PUMP UNIT, ALLOWING
ROTATION OF THE PUMP IN EITHER DIRECTION.
2. THE CONTROLLER IS ENERGIZED BY TWO LOCAL CONTROL SWITCHES MOUNTED ONE
ON EACH SIDE OF THE BULKHEAD IN CLOSE PROXIMITY TO THE DOOR.
3. RED AND GREEN LIGHTS LOCATED AT THE REMOTE STATION, AND ENERGIZED BY LIMIT
SWITCHES MOUNTED AT EACH END OF THE DOOR TRAVEL, INDICATE DOOR POSITION AS
FOLLOWS:
REDLIGHT
GREEN LIGHT
FLASHING RED LIGHT -
DOOR OPEN
DOOR CLOSED
DOOR INTERMEDIATE
4. THE DOOR MAY BE OPENED OR CLOSED FROM THE LOCAL STATION, BUT CLOSED
ONLY FROM THE REMOTE STATION.
SECTION III
INSTALLATION PROCEDURE
A. HYDRAULIC BOLTED TYPE OF DOOR
THE WALZ & KRENZER SLIDING WATERTIGHT DOOR AND FRAME IS A PRECISION PIECE OF
MACHINERY. EACH DOOR AND FRAME ASSEMBLY IS STRESS RELIEVED PRIOR TO
MACHINING AND, AFTER ASSEMBLY, IS HYDRO-ST A TI CALLY TESTED TO FULL DESIGN HEAD
PRESSURE PRIOR TO LEA YING OUR WORKS.
THESE DOORS HA VE A SEALING GASKET, CONSEQUENTLY, WHEN THE DOOR IS WEDGED
INTO THE CLOSED POSITION THERE IS FULL MET AL TO MET AL CONT ACT BETWEEN THE
BRASS FACE 0 F THE DOOR AND STEEL SEAT OF THE FRAME. THE DOOR ASSEMBLY IS
ESSENTIALLY THE EQUIVALENT OF A LARGE GATE VALVE. ANY DISTORTION AFFECTS THE
WATERTIGHT INTEGRITY. (SEE U.S.C.G. TEST FOR TIGHTNESS, PAR. NO. 163.001-6 (b)(5) :
"The degree of contact between door and frame shall be such as to exclude a .003" feeler gauge or its clear passage through and between the sealing surfaces at any point around the sealing perimeter."
THE FOLLOWING PRECAUTIONS SHOULD BE NOTED:
1. NEVER COMPLETELY WELD MOUNTING ANGLE INTO POSITION UNTIL MOST OF THE
HEAVY SHIP' S STRUCTURE IN THE VICINITY OF THE BULKHEAD, OVERHEAD DECKS AND
SUPERSTRUCTURE ARE WELDED IN PLACE. ADDITIONAL WELDING IN THE AREA AND
ADDITIONAL WEIGHT OF SUPERSTRUCTURE COULD CAUSE DISTORTION OF THE DOOR
FRAME MAKING IT NECESSARY TO CUT THE LINER FREE AND REWELD AND RETRUE
THE SURF ACE IN ORDER TO COMPLY WITH THE CLEARANCES REQUIRED BY THE U.S.
COAST GUARD. r ·
2. IT IS WISE TO LEA VE THE DOOR FRAME AND MOUNTING ANGLE TACKED IN PLACE
UNTIL MOST OF THE WORK IN THE AREA IS COMPLETED. THESE TACKS CAN BE EASILY
BROKEN PERMITTING THE DOOR, FRAME AND LINER TO ALIGN ITSELF FREELY BEFORE
FINAL WELDING.
II
~_t)\A. 10 U~C..-2.A \-\EX B.EAD BOLT ')(.:2'' LG..) BY Y~'R.l:> ----..
G;~RLO~ \\-\E.RMO-S\JR~.l'\O.Gl2-0 , 0 • ....,., ·!sx3" G~SKE_\ :o'( YARD
3. JI
7'+ LOC.K Wt\CO\iE:-R 5'( Yt\R'D 7'4' D'A· IOU~<:- 2. B HE.X HE.~b . NtJT .BY YA..Rb --~
BULKH E..~D -----
\-\YD. C..YL\NDE..R BY W~ K
Wf\"TERT\G\-\T '5L\D\ ~G t>OOR
BY W~K
--- FR ~tv\ E A/2:/2·} Y- 8 '( W ~ K
MT& ANGLE. BY YARD
)l
SECTION III (Continued)
INSTALLATION PROCEDURE (Continued)
B. REMOVE DOOR FROM FRAME PROPER. LAY OUT OPENING IN BULKHEAD TO FIT MOUNTING
ANGLE AS CLOSE AS POSSIBLE.. CUT OPENING WITH ACETYLENE TORCH. WARPING MAY BE
PREVENTED BY FOLLOWING FLAME WITH A SMALL STREAM OF WATER, APPROXIMATELY 6"
(l5CM) BACK OF TORCH. MOUNTING ANGLE SHOULD BE CUT AND FIITED TO THE FRAME.
MOUNTING ANGLE, OF COURSE, SHOULD BE FLAT AND TRUE.
CLAMP MOUNTING ANGLE TO FRAME AND AVOIDING EXCESSIVE HEAT, TACK WELD AT 12"
INTERVALS.
PLACE ENTIRE UNIT AGAINST BULKHEAD AND TACK WELD FRAME ANGLE ONLY AT
CONTACT POINTS. DO NOT ATTEMPT TO DRAW BULKHEAD INTO ALIGNMENT WITH LINER.
CAREFULLY PACK SHIMS INTO ALL OPEN SPACES BETWEEN THE BULKHEAD AND ANGLE.
LEAVING FRAME ATTACHED, WELD ANGLE TO BULKHEAD AS FOLLOWS:
1. WELD ONE BEAD UPWARDS APPROXIMATELY 12" (30CM) LONG ON THE OPERATOR'S
LEFT FROM THE DOOR SIDE OF BULKHEAD.
2. CHANGE TO OPPOSITE SIDE OF BULKHEAD, WELDING ONE BEAD UPWARDS
APPROXIMATELY 12" (30CM) FROM THE BOTTOM OF THE OPERATOR'S LEFT.
3. ON THE SAME SIDE OF THE BULKHEAD, WELD ONE BEAD UPWARDS APPROXIMATELY 12"
(30CM) LONG ON THE OPERATOR'S RIGHT.
4. CHANGE TO DOOR SIDE OF BULKHEAD, WELD ONE BEAD APPROXIMATELY 12" (30CM).
PROCEED, BEGINNING WITH OPERATION 1, UNTIL ANGLE IS COMPLETELY WELDED ON BOTH
SIDES, BOTH FORWARD AND AFT SIDES OF BULKHEAD.
FOLLOW A SIMILAR PROCEDURE IN WELDING TOP AND BOTTOM.
REMOVE FRAME FROM ANGLE. CHECK ANGLE FOR FLATNESS. NOTE THAT ANY DEVIATION
IN FLATNESS WILL BE CARRIED THROUGH TO THE FRAME WHEN IT IS SECURELY BOLTED TO
THE BULKHEAD WHICH WOULD, IN TURN, DISTORT THE FRAME SEAT AND RESULT IN A
POORLY FITTED DOOR.
THE ABOVE SHOULD NOT BE INTERPRETED AS A DEFINITE REQUIREMENT, BUT AS A
PROCEDURE THAT HAS BEEN TRIED AND FOUND TO WORK SATISFACTORILY. IN ANY CASE,
EVERY EFFORT SHOULD BE MADE TO KEEP THE HEAT AT A MINIMUM AND DISTRIBUTED AS
EVENLY AS POSSIBLE.
CHECK DOOR SEAT AND FRAME SEAT TO SEE THAT THEY ARE FREE FROM DAMAGE. A
REASONABLE AMOUNT OF GREASE SHOULD BE APPLIED TO THE SEAT OF THE FRAME AND
THE SEAT AND WEDGING SURF ACE OF THE DOOR.
LOCATE DOOR IN FRAME AND REPLACE WEDGE PLATES. BOLT GUIDE RAILS TO FRAME,
INST ALL AND WELD SUPPORT BRACKET (FURNISHED BY SHIPYARD) AS SHOWN ON
ASSEMBLY DRAWING. INSURE THAT GUIDE RAILS ARE PROPERLY ALIGNED WITH FRAME
BEFORE WELDING. LOCATE CYLINDER MOUNTING BRACKET, AS SHOWN ON DOOR
ASSEMBLY DRAWING, AND SECURE ACCORDINGLY. REINFORCE BULKHEAD IN WAY OF
CYLINDER MOUNTING BRACKET TO INSURE SUFFICIENT RIGIDITY. INSTALL CYLINDER.
THESE INSTRUCTIONS ARE BASED ON THE INSTALLATION OF A HORIZONTAL DOOR SIMILAR
PROCEDURE WILL APPLY TO VERTICAL DOOR INSTALLATION.
INSTALLATION PROCEDURE (Continued)
C. HYDRAULIC EQUIPMENT
WE WILL NOT ATTEMPT TO MAKE FITTING RECOMMENDATIONS EXCEPT THAT THEY SHOULD
BE OF A CLASS SATISFACTORY FOR THE PRESSURE SHOWN AND ACCEPTABLE TO
REGULATORY AGENCIES. ALL LINES ARE SUBJECT TO HIGH PRESSURE EXCEPT THE 3/4"
(l.88CM) LINE BETWEEN THE SUPPLY TANK AND THE VALVE BLOCK, AND ALL DRAIN LINES.
THE TUBING SIZES SPECIFIED ON DRAWING, PAGE 23, ALLOW FOR A REASONABLE NUMBER
OF BENDS AND FITTINGS AND IN NO CASE SHOULD A SMALLER SIZE BE USED:
NOTE: IN THE EVENT THAT TUBE RUNS EXCEED 60 FEET (1800CM) OR EXCESSIVE BENDS
ARE USED, TUBING SIZE MUST BE INCREASED ACCORDINGLY.
IT IS MOST IMPORTANT THAT ALL HYDRAULIC LINES BE CLEANED AND FLUSHED BEFORE
CONNECTING TO ANY OF THE PUMPS, VAL YES OR CYLINDERS. DUE TO THE NATURE OF THE
HYDRAULIC CIRCUIT IT MAY BE NECESSARY TO DISASSEMBLE ALL COMPONENTS IN THE
SYSTEM IF THE SYSTEM BECOMES CONTAMINATED. USE A BENDING TOOL TO MAINTAIN
MAXIMUM AREA. TUBING SHOULD BE CAREFULLY AND PROPERLY FITTED, MAKING SURE
THAT NO BURRS, CHIPS OR OTHER FOREIGN MATTER ARE ALLOWED IN THE SYSTEM.
TUBING SHOULD BE INSTALLED AT A SLIGHT PITCH WITH VENT VALVES PLACED AT THE
HIGHPOINT.
IN THE FOLLOWING PARA GRAPHS, ALL ITEMS IDENTIFIED BY # REFER TO DETAIL "C", PAGE
24. MAKE CONNECTIONS AS SHOWN ON DETAIL "B''. WHEN INSTALLATION IS COMPLETE,
FILL TANK WITH A GOOD GRADE OF PETROLEUM BASE HYDRAULIC FLUID HAVING A
VISCOSITY OF 250-325 SSU AT 100 degrees F. OPEN VALVES #19 AND1f20.
CAUTION: DO NOT OPERATE DOOR WITH VALVES #19 AND #20 CLOSED AS THIS WILL
BACK-PRESSURE THELOCAL HAND PUMP AND CAUSE THE SHAFT SEALS TO
BLOW.
INSTALLATION PROCEDURE (Continued)
IT IS ASSUMED THAT THE DOOR IS IN AN OPEN POSITION. OPEN VENT ON MOUNTING END
OF CYLINDER, ROTATE CRANK IN CLOSING DIRECTION AT REMOTE STATION UNTIL OIL
FLOWS FREELY FROM VENT. CLOSE VENT AND CONTINUE TO ROTATE CRANK UNTIL DOOR
CLOSES.
REMOVE 1/4" (.375CM) SOCKET HEAD PIPE PLUG FROM DRAIN LINE IN QUAD CHECK VAL VE,
ITEM H7 PAGE 24, UNTIL OIL FLOWS. OPEN VENT AT ROD END OF CYLINDER. ROTATE
CRANK ON LOCAL PUMP IN OPENING DIRECTION UNTIL ALL AIR IS EMITIED. CLOSE VENT
AND ROTATE CRANK UNTIL DOOR IS OPENED. IT MAY BE NECESSARY TO VENT MOUNTING
END OF CYLINDER AND ROTATE LOCAL PUMP EMITTING AIR AND CLOSING DOOR; THEN
REVERSE OPERATION UNTIL SYSTEM IS FREE FROM AIR. IT IS IMPERATIVE THAT ALL AIR IS
OUT OF THE SYSTEM TO INSURE PROPER OPERATION.
IF THE DOOR DOES NOT CLOSE PROPERLY, FOREIGN MATIER WILL UNDOUBTEDLY BE
FOUND UNDER ONE OF THE CHECKS OR CHECK MAY BE STICKING DUE TO CONTAMINATION
OF OIL, ALLOWING OIL TO ESCAPE FROM THE CLOSING SIDE OF THE CIRCUIT. A SIMILAR
CONDITION IN THE OPENING SIDE OF 1HE LINE WOULD AFFECT THE OPENING OF THE DOOR.
REFER TO DRAWING PAGE 33, ITEMS #9 AND #12.
THE CLOSING CIRCUIT IS A DUPLICATE OF THE OPENING CIRCUIT EXCEPT THAT, FROM THE
REMOTE STATION, THE DOOR MAY BE CLOSED ONLY. A SHUTfLE VALVE IS USED TO
CONTROL THE FLOW OF OIL, ITEM 10 OF PAGE 33. THIS VALVE IS AUTOMATICALLY
OPERATED BY A PILOT PRESSURE CREATED BY THE PUMPS AS ROTATION IS CHANGED. THE
CIRCUIT IS SO ARRANGED THAT A FEW SECONDS ARE REQUIRED TO ALLOW THE SHUTfLE
VAL VE TO SHIFT FROM ONE POSITION TO ANOTHER. THEREFORE, ·IT IS DESIRABLE TO
DELAY REVERSING ROTATION OF LOCAL PUMPS FOR A FEW SECONDS AS AN IMMEDIATE
CHANGE OF ROTATION TENDS TO INCREASE DELAY IN MOVEMENT OF DOOR RATHER THAN
DECREASE IT.
INSTALLATION PROCEDURE (Continued)
THE LOCAL PUMP, #5, DRAWING PAGE 33, IS A HIGH CAPACITY, LOW SPEED, GEAR TYPE
POSITIVE DISPLACEMENT, REVERSIBLE PUMP. IN THE EVENT THAT THE SHIP STRUCTURE IS
SUCH THAT IT IS NOT POSSIBLE OR PRACTICAL TO EXTEND THE CRANK THROUGH THE
BULKHEAD FOR OPERATION ON THE OPPOSITE SIDE, TWO PUMPS MAY BE SUPPLIED IN LIEU
OF ONE, BOTH OF WHICH WOULD HA VE SINGLE SHAFT EXTENSIONS AND COULD BE
LOCATED IN ANY CONVENIENT LOCATION NEAR THE DOOR APPROVED BY THE U.S. COAST
GUARD. WHERE TWO LOCAL PUMPS ARE USED, INCREASE TUBING SIZE TO 3/4" (1.88CM) O.D.
BETWEEN VAL VE BLOCK AND PUMPS. A HINGED TYPE HANDLE MAY BE FURNISHED IN
LIEU OF THE RIGID HANDLE IN THE EVENT THAT SPACE IN THE PASSAGEWAY IS LIMITED.
THIS DESIGN HAS ALSO BEEN APPROVED BY THE U.S. COAST GUARD.
THE REMOTE PUMP, #6, . DRAWING PAGE 33, IS A DUPLICATE IN CONSTRUCTION AND
CAPACITY OF PUMP #5, EXCEPT THAT IT IS NON-REVERSIBLE INASMUCH AS IT IS ONLY
NECESSARY TO CLOSE THE DOOR FROM THE REMOTE STATION. A SURGE TANK, #1
DRAWING PAGE 33, 2 GALLON (7.6 LITERS) CAPACITY, IS PROVIDED TO BE INSTALLED NEAR
THE REMOTE PUMP TO ALLOW FOR A SLIGHT SURPLUS OF OIL AND ALSO THE EXPANSION
AND CONTRACTION RESULTING FROM THE UNEQUAL ENDS OF THE CYLINDER DUE TO
PISTON DISPLACEMENT. SHUT-OFF VALVE H-19 AND H-20, PAGE 24, ARE RECOMMENDED SO
THAT OIL IN THE TANK MAY BE SHUT OFF IN THE EVENT OF LEAKAGE IN THE JOINTS OR IF
REPAIRS MAY BE NECESSARY. AN AUXILIARY TANK IS MOUNTED WITHIN 10' OF DOOR TO
INSURE DOOR OPERATION EVEN IN THE EVENT OF RUPTURED HYDRAULIC TANK LINE
BEYOND 10' OF DOOR.
A SINGLE DOUBLE-ACTING CYLINDER, #4, DRAWING PAGE 33, IS 2-3/4" (6.88CM) BORE WITH A
STROKE SUIT ABLE FOR THE OPENING OF THE DOOR SHOWN. THIS CYLINDER IS EQUIPPED
WITH A NON-ADJUSTABLE PACKING GLAND AND WIPER WHICH PREVENTS LEAKAGE AT
EITHER THE OPERATING PRESSURE WHICH IS A MAXIMUM OF 800 P.S.I. (56KG/SQ.CM) OR THE
STATIC HEAD WHICH MAYBE AS LOW AS 3 P.S.I. (.21KG/SQ.CM)
INSTALLATION PROCEDURE (Continued)
DEPENDING ON THE LOCATION OF REMOTE STATION. REMOVAL OF CYLINDER ROD NUT
WILL ALLOW FOR OPENING AND CLOSING THE DOOR IN THE EVENT OF MECHANICAL
FAILURE. MOTOR PUMP, #H-9, DRAWING PAGE 24, IS AN INTERNAL AND EXTERNAL PUMP
DRIVEN BY A TORQUE TYPE MOTOR VAL VE ASSEMBLY, PUMP AND MOTOR ARE MOUNTED
ON A COMMON BASE, DETAIL "B" PAGE 24. HYDRAULIC CONNECTIONS HAVE BEEN MADE
AT THE FACTORY AND ENTIRE ARRANGEMENT HAS BEEN TESTED AS A COMPLETE UNIT.
PRESSURE SWITCH, DRAWING PAGE 26, HAS BEEN SET AT APPROXIMATELY 750 P.S.I.
IMPORTANT NOTES:
1. WHERE POSSIBLE WE SUGGEST THAT HYDRAULIC LINES TO THE CYLINDER BE RUN
UNDER THE DOOR TO MINIMIZE THE POSSIBILITY OF TRAPPING AIR. BLEED VALVES
SHOULD BE INSTALLED WHERE HIGH POINTS OCCUR IN THE PIPING.
2. IT IS MOST IMPORTANT THAT ALL HYDRAULIC LINES BE CLEANED AND FLUSHED
BEFORE CONNECTING TO ANY OF THE PUMPS, VAL VE BLOCKS, CYLINDERS, ETC.
3. DO NOT REMOVE THE PLUGS FROM ANY OF THE COMPONENTS UNTIL READY TO MAKE
CONNECTIONS.
4. DUE TO THE NATURE OF THE HYDRAULIC CIRCUIT, IF THE ABOVE PROCEDURE IS NOT
FOLLOWED IT MAY REQUIRE COMPLETE DISASSEMBLY OF ALL COMPONENTS TO
REMOVE ANY ENTRAINED FOREIGN PARTICLES.
5. THE OIL IN THIS CIRCUIT DOES NOT HA VE UNI-DIRECTIONAL FLOW AND FOR THIS
REASON CANNOT BE FLUSHED AFTER COMPONENTS ARE CONNECTED.
D. HYDRAULIC EQUIPMENT- HAND OPERATED DOOR ONLY - REFER TO PAGE 37.
THE SAME PROCEDURE APPLIES TO THIS DOOR AS THAT OF THE POWER OPERATED DOOR
REFER TO PARAGRAPH "B'' AND DISREGARD ALL DATA PERTAINING TO POWER EQUIPMENT.
INSTALLATION PROCEDURE (Continued)
E. REMOTE INDICATOR, PAGE 34.
1. LOCATE AND SECURE·TRANSMITTING UNIT ON TOP GUIDE RAIL ASSEMBLY AS SHOWN ON
DRAWING. DO NOT ATTACH LEVER TO DOOR YET.
2. LOCATE AND SECURE INDICATING UNIT WHEREVER DESIRED.
3. INSTALL CONDUIT BETWEEN INDICATOR AND TRANSMITTER USING THE CONNECTORS
SUPPLIED. KEEP THE NUMBER OF BENDS IN THE CONDUIT TO A MINIMUM. RADIUS OF
EACH BEND TO BE A MINIMUM OF 5,, (12.5 CM). A BEND BLOCK FOR THIS PURPOSE IS
F1JRNISHED FOR THIS INSTALLATION. BE SURE TO REMOVE BURRS FROM END OF
CONDUIT. CONNECTORS ARE F1JRNISHED TO BE USED BETWEEN LENGTHS.
4. SUPPORT CONDUIT AT A MAXIMUM OF 4 FOOT (120CM) INTERVALS, CLIPS FOR WHICH
ARE F1JRNISHED FOR THIS INSTALLATION.
5. IN THE EVENT THAT CONDUIT IS TO PASS THROUGH WATERTIGHT BULKHEAD OR DECK,
STUFFING GLANDS ARE SUPPLIED IF ORDERED
6. REMOVE SPENT TUBE FROM TRANSMITTER, AND REMOVE POINTER AND NYLON GUIDE
FROM INDICATOR PASS CABLE THROUGH CONDUIT TO BE SURE THAT ALL BURRS AND
FOREIGN MATTER ARE REMOVED. WIPE CABLE CLEAN AND LUBRICATE WITH A LIGHT
GREASE, KEYSTONE #44 OR EQUIVALENT. REINSERT UNTIL IT PROTRUDES THROUGH TOP
OF INDICATOR
7. WITH INDICATOR ATTACHED TO TRANSMITTER ARM AND IN VERTICAL POSITION
WITH RESPECT TO GUIDE RAIL ASSEMBLIES ADJUST INDICATOR GUIDE SO
POINTER HOLE IS CENTERED BETWEEN "CLOSE" AND "OPEN,,. MARK CABLE AT
TOP OF GUIDE. REMOVE INDICATOR HOUSING AND CUT CABLE AT MARK.
8. REINSTALL HOUSING. POSITION GUIDE ON CABLE. INSTALL SET SCREWS AND POINTER.
9. ATTACHINDICATORARMTODOORUSINGINDICATORSTUD. OPENDOOR. CUTCABLETO
LENGTH LEAVING 3-1/2" (8. 75CM) EXTENDING THROUGH THE TRANSMITTER SPENT TUBE
OPENING.
10. CHECK INSTALLATION TO SEE THAT ALL CONNECTIONS ARE TIGHT.
INSTALLATION PROCEDURE (Continued)
F. ELECTRICALEQUIPMENT
ELECTRICAL EQUIPMENT IS TO BE INSTALLED AND WIRED IN ACCORDANCE WITHDRAWING
PAGE 27. LIMIT SWITCHES ARE TO BE INSTALLED AS SHOWN ON ASSEMBLY DRAWING.
ADJUST CLOSING LIMIT SWITCH TO OPEN CIRCillT 1/8" (.313CM) BEFORE DOOR REACHES
CLOSED POSITION. THE PRESSURE SWITCH STOPS 1RA VEL OF THE DOOR; THE LIMIT SWITCH
PREVENTS HUNTING AND ACTUATES SIGNAL LIGHTS. WHEN THE ABOVE IS COMPLETE,
ACTUATE MOTOR WITII POWER AND CHECK ROTATION WITH LOCAL CONTROL. IF
REQillRED, REVERSE ARMATURE LEADS AT REVERSING CONTROLLER. CLOSE DOOR FROM
THE LOCAL STATION CHECKING PRESSURE. PRESSURE SWITCH SHOULD OPEN CIRCUIT AT
APPROXIMATELY 750 (53KG/SQ.CM) P.S.I. ADJUST ONLY IF NECESSARY. ADJUST STOP BOLTS
TO DOOR AND TIGHTEN JAM NUTS. CHECK CLOSING LIMIT SWITCH FOR PROPER
ADJUSTMENT. OPEN DOOR AND CHECK ADJUSTMENT OF OPEN LIMIT SWITCH. IT MAY NOW
BE NECESSARY TO BLEED ADDITIONAL AIR FROM CYLINDER. AS PREVIOUSLY STATED,
DOOR WILL NOT OPERATE PROPERLY WITH AIR IN THE SYSTEM. AFTER THIS OPERATION IS
COMPLETE, CHECK OPERATION AND SIGNAL LIGHTS FROM THE REMOTE STATIONS. LEAVE
SWITCH IN CLOSED POSITION AND CHECK LOCAL OPERATION. IF WIRING IS CORRECT, DOOR
WILL OPERATE ACCORDING TO REGULATIONS.
THE ELECTRICAL EQUIPMENT DOES NOT REQUIRE ANY SPECIAL ATTENTION, THEREFORE,
NORMAL PROCEDURE SHOULD BE FOLLOWED.
SECTION IV
TEST PROCEDURE
A. FOR TESTING PROCEDURE, OPERA TE DOOR IN ACCORDANCE WITII SECTION V, OPERA TING
INSTRUCTIONS.
B. 1. ALL HYDRAULIC COMPONENTS HA VE BEEN FACTORY TESTED.
2. WORKING PRESSURE FOR THIS SYSTEM IS 750 (53KG/SQ.CM) P:S.I. RELIEF VALVES FOR
THIS SYSTEM ARE SET AT SLIGHTLY ABOVE THIS.
3. DUE TO CIRCUIT DESIGN IT IS NECESSARY TO DISCONNECT ALL COMPONENTS AND PLUG
ENDS OF PIPING IF TEST PRESSURE FROM AN EXTERIOR SOURCE IS USED. IF THIS IS NOT
DONE, DAMAGE CAN RESULT TO THE RELIEF VALVE, PRESSURE SWITCH, VALVE SPRINGS
AND SEALS, AND TO THE PUMP SEALS.
SECTIONV
OPERATING INSTRUCTIONS
ELECTRO-HYDRAULIC SLIDING WATERTIGHT DOORS
A. LOCAL POWER OPERATION
1. ENGAGE EXTERNAL DISCONNECT ON MOTOR CONTROLLER, PAGE 27.
2. TO OPEN - MOVE LOCAL CONTROL SWITCH HANDLE TO "OPEN" POSITION AND HOLD
UNTIL DOOR IS OPEN AND MOTOR STOPS. UPON RELEASING, HANDLE WILL RETURN
TO NEUTRAL.
3. TO CLOSE - MOVE LOCAL CONTROL SWITCH HANDLE TO "CLOSE" POSITION. HANDLE
WILL ST A Y IN THIS POSITION. WARNING HORN WILL SOUND FOR 5-10 SECONDS AND
THEN DOOR WILL AUTOMATICALLY CLOSE AND MOTOR WILL SHUT OFF. HANDLE
MUST BE RETURNED TO NEUTRAL MANUALLY.
NOTE: IF HANDLE IS LEFT IN CLOSE POSITION, DOOR MAY BE OPENED FROM OPPOSITE
SIDE OF BULKHEAD BUT WILL AUTOMA TI CALLY CLOSE AFTER WARNING HORN
SOUNDS FOR 5-10 SECONDS.
B. REMOTE POWER OPERATION
TO CLOSE - MOVE DOOR CONTROL SWITCH TO "CLOSE". DOOR WILL AUTOMATICALLY
CLOSE AND GREEN INDICATOR LIGHT WILL REMAIN LIGHTED AT END OF CYCLE.
NOTE: (a) IF SWITCH IS LEFT IN "CLOSE" POSITION, DOOR MAY BE OPENED LOCALLY
BUT WILL AUTOMATICALLY CLOSE WHEN CONTROL SWITCH RETURNS TO
NEUTRAL.
(b) DOOR MAY NOT BE OPENED FROM THE REMOTE POSITION.
SECTION V -(Continued)
OPERATING INSTRUCTIONS
ELECTRO-HYDRAULIC SLIDING WATERTIGHT DOORS
C. REMOTE HAND PUMP
1. ROTA TE HAND PUMP AS SHOWN ON ROTATION PLATE MOUNTED THEREON. THIS
ROTATION PLATE INDICATES THE DIRECTION THE PUMP MUST ROTATE TO EITHER
"OPEN" OR "CLOSE".
NOTE: IT MAY BE NECESSARY TO ROTATE HAND CRANK VERY FAST TO BREAK DOOR
LOOSE WHEN INITIALLY OPENING.
D. REMOTE HAND PUMP
ROTATE HAND PUMP IN "CLOSE" DIRECTION AS SHOWN ON ROTATION PLATE. DOOR
POSITION WILL SHOW ON MECHANICAL INDICATOR MOUNTED ABOVE PUMP.
NOTE: DOOR MAY BE CLOSED ONLY FROM THIS REMOTE LOCATION.
CAUTION: DO NOT OPERATE DOOR WITH SHUT-OFF VALVES, ITEMS H-19 AND H-20,
CLOSED AS THIS WILL BACK-PRESSURE THE LOCAL HAND PUMP AND CAUSE
THE SHAFT SEALS TO BLOW.
SECTION VI
OPERATING INSTRUCTIONS
HAND HYDRAULIC SLIDING WATERTIGHT DOORS
A. LOCAL HAND OPERATION
l. ROTATE HAND PUMP AS SHOWN ON ROTATION PLATE MOUNTED THEREON. THIS
ROTATION PLATE INDICATES THE DIRECTION THE PUMP MUST ROTATE TO EITHER
"OPEN" OR "CLOSE".
NOTE: IT MAY BE NECESSARY TO ROTATE HAND CRANK VERY FAST TO BREAK DOOR
LOOSE WHEN INITIALLY OPENING.
B. REMOTEHANDPUMP
1. ROTATE HAND PUMP IN "CLOSE" DIRECTION AS SHOWN ON ROTATION PLATE. DOOR
POSITION WILL SHOW ON MECHANICAL INDICATOR MOUNTED ABOVE PUMP.
NOTE: DOOR MAY BE CLOSED ONLY FROM THIS REMOTE LOCATION.
SECTION VJJ
A. MECHANICAL
MAINTENANCE
SEE LUBRICATION CHART, PAGE 22, FOR TYPE AND FREQUENCY OF LUBRICATION FOR
MECHANICAL PARTS.
1. OPEN-CLOSE CYLINDER, NO. 4 DRAWING PAGE 33.
MAINTENANCE IS VERY SELDOM NECESSARY ON THIS ITEM, BUT IN CASE OF SEVERE
LEAKAGE, REPAIR SHOULD BE UNDERTAKEN BY A TECHNICIAN UNDER SHOP
CONDITIONS AS FOLLOWS:
a) REMOVE TRU-ARC RETAINER, ITEM 4-9, USING TRU-ARC PLIERS SUPPLIED IN SPARE
PARTS.
b) REMOVE GLAND, ITEMS 4-11 AND 4-12, BY APPLYING SMALL AMOUNT OF AIR
PRESSURE TO CYLINDER PORT.
c) IF LEAKAGE WAS OBSERVED AROUND THE ROD, REPLACE ITEMS 4-6, AND KLOZURE, ITEM4-8.
d) IF OIL WAS BY-PASSING AROUND THE PISTON (IT TAKES MANY YEARS TO WEAR OUT
TO THIS POINT) REPLACE CUPS, ITEMS 4-1, AND THE STATIC "O" RING, ITEM 4-2.
e) WHEN REASSEMBLING, EXIREME CARE MUST BE OBSERVED TO AVOID DAMAGE TO
THE "O" RING, ITEM 4-5, AND CUPS, ITEM 4-1, ON TRU-ARC GROOVE AND CYLINDER
PORTS, AND TO AVOID SCRATCHING THE ROD AND CYLINDER BORE.
2. MOTOR PUMP, #5 DRAWING PAGE 33 .
LOCAL HAND PUMP, #6, DRAWING PAGE 33.
IT IS SUGGESTED THAT, IN CASE OF MALFUNCTION, PUMP BE SENT BACK TO WALZ &
KRENZER FOR OVERHAUL. HOWEVER, SEALS MAY BE REPLACED IN CASE OF LEAKAGE
AROUND THE SHAFT. THIS SHOULD BE UNDERTAKEN ONLY BY QUALIFIED TECHNICIANS
UNDER SHOP CONDITIONS.
3. CONTROL VALVES, DRAWING PAGE 33, ITEMS 9, 10, 11, 12 & 13.
THESE VALVES ARE SUPPLIED, BOLTED TOGETHER IN A SANDWICH TYPE OF STACK.
NORMALLY, IF PROPER SYSTEM CLEANLINESS AND INSTALLATION PROCEDURE IS
OBSERVED, THE ONLY MAINTENANCE REQUIRED WOULD BE THE OCCASIONAL
REPLACEMENT OF AN "O" RING BETWEEN THE VALVES OR ALUMINUM GASKET AND "O"
RING UNDER CAPS AND PLUGS. THIS MAY BE ACCOMPLISHED BY DISASSEMBLING
VALVE STACK OR REMOVING CAPS AND PLUGS AND REPLACING "O" RINGS AND GASKET
AS REQUIRED.
SECTION VIJ-(Continued)
B. HYDRAULIC - (Continued)
MAINTENANCE
4. PRESSURE SWITCH, DRAWING PAGE 26.
THIS VAL VE IS ALSO BOLTED TOGETHER WITHIN THE VAL VE BLOCK AND REQUIRES
SYSTEM CLEANLINESS. THE ONLY MAINTENANCE REQUIRED WOULD BE THE "O" RINGS
BETWEEN THE VAL YES, ALUMINUM GASKET AND "O" RING UNDER THE CAPS AND PLUGS
OR REPLACEMENT OF THE MICRO SWITCH.
C. ELECTRICAL EQUIPMENT
1. LOCAL CONTROL SWITCH, DRAWING PAGE 30.
CONT ACT BLOCKS ARE SUPPLIED IN THE SPARE PARTS AND MAY BE REPLACED IF FOUND
NECESSARY.
2. LIMIT SWITCH, NO. 51ML7
THE ONLY MAINTENANCE REQUIRED WOULD BE THE REPLACEMENT OF THE BASIC
MICRO-SWITCH DT-2R711-A7. THIS IS ACCOMPLISHED BY REMOVING THE COVER AND
SWITCH MOUNTING SCREWS AND REPLACING DEFECTIVE BASIC SWITCH.
3. BALDOR ELECTRIC MOTOR
DUE TO THE SHORT OPERATING CYCLE AND THE FACT THAT THE BEARINGS ARE PRE
LUBRICATED, LITTLE OR NO MAINTENANCE SHOULD BE REQUIRED. HOWEVER,
BEARINGS AND SEALS ARE SUPPLIED AS SPARES AND SHOULD BE REPLACED ONLY BY
QUALIFIED TECHNICIANS UNDER SHOP CONDITIONS.
SECTION Vll-(Continued)
MAINTENANCE-( Continued)
4. CONTROLLER, DRAWING PAGE 27.
NORMAL MAINTENANCE TO THE CONTROLLER WOULD BE OCCASIONAL REPLACEMENT
OF A BLOWN CONTROL CIRCUIT FUSE OR A BURNED-OUT HEATER. THE ENCLOSURE MAY
BE OPENED BY DISENGAGING EXTERNAL DISCONNECT, LOOSENING THE HOLD-DOWN
BOLTS AND SWINGING OPEN THE COVER.
CAUTION: DO NOT ATTEMPT TO OPEN ENCLOSURE WITH EXTERNAL DISCONNECT
ENGAGED AS DAMAGE TO THE INTERNAL SWITCH ACTUATOR WILL RESULT.
FUSES ARE REPLACED BY USING FUSE PULLERS. THE HEATER COILS ARE EXTRACTED BY
REMOVING THE SCREW HOLDING THEM IN PLACE. REPLACEMENT OF CONT ACTS, SHUNT
COIL OR TRANSFORMER SHOULD BE UNDERTAKEN ONLY BY A QUALIFIED TECHNICIAN.
SECTION VII (Continued)
LUBRICATION CHART
HYDRAULIC. HORIZONTAL- SLIDING WATERTIGHT DOOR
PART
LUBIUCATED
SEALING SURF ACES
AROUND PERIPHERY
OF DOOR
DOOR ROLLERS
PINS ALEMITE
STD. FITTING
SEALING SURF ACES
AROUND PERIPHERY
OF DOOR
LUBRICANT AMOUNT APPLICATION FREQUENCY
LIGHT PETROLEUM THIN FILM APPLY WITH EVERY TWO
BASE GREASE BRUSH OR RAG WEEKS
GOOD GRADE AS NECESSARY GREASE GUN EVERY TWO
OF GREASE WEEKS
HYDRAULIC, VERTICAL- SLIDING WATERTIGHT DOOR
LIGHT PETROLEUM
BASE GREASE .
THIN FILM
APPLY WITH EVERY TWO
BRUSH OR RAG WEEKS
SECTION VIII
TROUBLE SHOOTING GUIDE
REMEDY
l. MOTOR SHUTflNG OFF
BEFORE DOOR COMPLETELY
CLOSED.
PROBLEM
PRESSURE SWITCH SET TOO LOW.
2. MOTOR WlLL NOT SHUT OFF RELIEF VAL VE SETTING TOO LOW.
AT END OF CYCLE. SHOULD BE HIGHER THAN
PRESSURE SWITCH.
3. MOTOR REPEATEDLY SHUTS "CLOSE" LIMIT SWITCH ARM NOT
OFF & STARTS UP AGAIN AT ADJUSTED PROPERLY.
END OF CLOSE CYCLE.
4. MOTOR WILL NOT SHUT OFF "OPEN" LIMIT SWITCH ARM
AT END OF OPEN CYCLE. NOT ADJUSTED PROPERLY.
5. DOOR WILL NOT OPEN UNDER DOOR CLOSING TOOF AR INTO
FULL POWER. TAPERED SEAT.
6. DOORMOVINGVERYSLOW l. RELIEFVALVESETTOOLOW.
AND WITH JERKY MOTION.
7. EXCESSIVE LENGTH OF TIME
TO REVERSE DIRECTION.
8. POWER UNIT NOT STARTING
2. QUAD CHECK BALLS NOT
SEATING PROPERLY.
3. SHUTfLE UNIT BLEED VAL VE
OPEN TOO FAR. PART OF OIL
PASSING TO TANK.
4. AIR IN HYDRAULIC SYSTEM.
AIR IN SYSTEM.
l. OVERLOADRELAYMAY
PROBABLE CAUSE
SETTING SHOULD BE BETWEEN
720 & 800 P.S.I. (50.6 & 56.2KG/SQ.CM)
SETTING SHOULD BE BETWEEN
900 & 1000 P.S.l. (63.3 & 70.3 KG/SQ.CM)
ABOVE VALVE BLOCK.
SET LIMIT SWITCH ARM SO IT
ACTUATES JUST PRIOR TO PRESSURE
SWITCH SHUTfING OFF MOTOR.
ADJUST LIMIT SWITCH ARM SO IT
WILL ACTUATE AND STOP MOTOR.
SET STOP BOLTS SO BRASS OVERLAPS
STEEL SEAT BY 3/4" (l.875CM) MIN. TO
I" (2.5CM) MAX.
I. SEE REMEDY FOR PROBLEM 2.
2. RESEATSTAINLESSSTEELBALLS
USING HAMMER AND BRASS ROD.
3. CLOSE NEEDLE VALVES UNTIL
THEY BOTTOM COMPLETELY.
BACK OFF 1/8 TO 1/4 TURN.
4a CHECK LEVEL OF OIL IN
EXPANSION TANK
b. BLEED OFF AIR AT ALL HIGH
POINTS.
CHECK LEVEL OF OIL IN EXPANSION
TANK. ADD OIL IFNECESSARY.
l. PRESS RESET BUTfON
2. FUSES IN THE CONTROLLER 2. REPLACE BAD FUSE.
MAY BE BLOWN.
3. CONT ACTS IN LOCAL CONTROL 3. REPLACE CONT ACT BLOCK.
SWITCH MAY BE DEFECTIVE.