NOAA SHIP RONALD H. BROWN
(R-104)
14 July 2017
ITEM NO. 16240 BASIC ITEM MED/JAL
DOOR RENEWALS AND MAINTENANCE
16240-1 l.0 ABSTRACT
1.1 This item describes maintenance for the ship’s watertight doors and renewal of various doors throughout the ship.
2.0 REFERENCES:
2.1 Drawing 624-6932863 INTERIOR JOINER DOORS
2.2 Technical Manual RB-167-00, Hydraulic Watertight Doors
2.3 NOAA Standard Item MOC-573-2, Overhaul/Repair of Hydraulic
Cylinders
3.0 ITEM LOCATION/DESCRIPTION: See para. 7.0
4.0 GOVERNMENT FURNISHED EQUIPMENT/MATERIAL/SERVICES:
4.1 Five(5)each Class A fire doors with frames. - $24,000
5.0 NOTES
5.1 The contractor and all subcontractors regardless of tier are advised to review other work items under this contract, including but not limited to 10420 to determine their effect on the work required under this work item. Many of the definitions relating to performance of this work item are found in references included in work item 10420.
6.0 QUALITY ASSURANCE REQUIREMENTS: None additional.
7. STATEMENT OF WORK REQUIRED
7.1. Accomplish the following for the five (5) each sliding watertight hydraulic doors.
7.1.1. Conduct an operational test of each door in the presence of the COR. Submit an as found condition report with findings and recommendations.
7.1.2.Drain and properly dispose of all hydraulic oil from each system.
7.1.3. Temporarily remove the hydraulic cylinder from each door from ship to shop. Accomplish the requirements of Reference 2.3 for each cylinder.
7.1.4. Reinstall the cylinders after completion of repairs.
7.1.5. Provide and install new hydraulic oil for each system. The oil currently utilized on board is Mobile DTE 16M, or equal.
7.1.6. Reinstall overhauled cylinders on each door.
7.1.7.Accomplish operational testing of each door in the presence of the
COR.
NOAA SHIP RONALD H. BROWN
(R-104)
14 July 2017
ITEM NO. 16240 BASIC ITEM MED/JAL
DOOR RENEWALS AND MAINTENANCE
16240-2
7.2. Remove and renew the following interior class A fire rated doors. See Reference 2.1 for guidance. Remove the existing doors and frames to scrap. Install new Government Furnished doors with frames with all hardware.
7.2.1. One (1) each door at 1-21-2. Door size: 37x78 ½, Swing: RHR, bulkhead cut size: 35x81; to include fire closure, door knob (non-locking, heavy duty lever operated both sides).
7.2.2. One (1) each door at 1-21-4. Size: 30x78 ½, Swing: LHR, bulkhead cut size: 35x81; to include fire closure, door knob (non-locking, heavy duty lever operated both sides), 8”x12” safety glass window.
7.2.3. One (1) each door at 3-48-2. Size: 30x78 ½, Swing: LHR, bulkhead cut size: 35x81; to include fire closure, door knob (non-locking, heavy duty lever operated both sides), 8”x12” safety glass window.
7.2.4. One (1) each door at 01-64-2. Size: 30x78 ½. RHR, bulkhead cut size: 35x81; to include fire closure, door knob (non-locking, heavy duty lever operated both sides), 8”x12” safety glass window.
7.2.5. One (1) each door at 2-49-2. Size: RHR, bulkhead cut size:
35x81; to include fire closure, door knob (non-locking, heavy duty lever operated both sides), 8”x12” safety glass window.
7.2.6. Paint doors to match original door’s color scheme.
7.2.7. Install new signage to match signage on the existing doors.