Camp Varnum Room Finish Schedule.pdf

PDF 162 KB Posted

Attached to
RIARNG CAMP VARNUM T-18 RENOVATIONS
Solicitation number
RFQ26006763
Issued by
Providence County, Rhode Island

About this file

This is a Room Finish Schedule document for Building T-18 at Camp Varnum, prepared in conjunction with the Rhode Island Army National Guard's renovation project managed through the State of Rhode Island Division of Purchases. The schedule specifies interior finishes for three areas: dormitory rooms, bathrooms, and stairs. Dormitory spaces feature wood baseboards, luxury vinyl tile (LVT) flooring, wood framing, gypsum drywall with paint finishes on both walls and ceilings, and a finished height of 7'-6" with one fire-rated view (VIF 1, 2). Bathrooms are finished with concrete epoxy flooring, gypsum drywall with paint on walls and ceilings at 8'-0" height with VIF 1, 3 designation. Stair areas include wood baseboards and framing, LVT flooring, and gypsum finishes at a 16'-4.5" height with VIF 1, 2 classification. Second-floor dormitory spaces match the first-floor dormitory specifications at 8'-10.5" height.

The specification document establishes three critical fire and moisture safety requirements: all gypsum wall and ceiling boards shall be 5/8" thickness; gypsum materials at stairs must be one-hour fire-rated; and gypsum materials in bathrooms must be water-resistant. These finish standards align with the broader T-18 renovation scope that includes life safety upgrades, mechanical systems, electrical work, plumbing, flooring replacement, and structural improvements required to comply with Rhode Island Building Code Commission and State Building and Fire Code standards. The schedule references approved construction design prints completed by Rowse Architects Inc. and is part of the comprehensive energy-efficient modernization project with a September 2026 anticipated start date and 16-month timeline to substantial completion.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DORMITORY WD LVT WD GYP PNT GYP PNT 7'-6" ± VIF 1, 2

FIN BASEMAT

ROOM FLOOR

ROOM FINISH SCHEDULE

REMARKS

WALLS CEILING

HGTMAT FIN MAT FIN TYPE

REMARKS:

BATHROOM CONC EPOXY CONC GYP PNT GYP PNT 8'-0" ± VIF 1, 3

STAIR WD LVT WD GYP PNT GYP PNT 16'-4 1/2" ± VIF 1, 2

2. GYPSUM WALL AND CEILING BOARDS SHALL BE 1 HOUR FIRE RATED AT STAIRS.

DORMITORY - 2ND FLR WD LVT WD GYP PNT GYP PNT 8'-10 1/2" ± VIF 1, 2

3. GYPSUM WALL AND CEILING BOARDS SHALL BE WATER RESISTANT AT BATHROOM

1. GYPSUM WALL AND CEILING BOARDS SHALL HAVE A THICKNESS OF 5/8"

Sheets and Views
24029A - Drawing Set-RM FIN SCH

File details come from the government source that posted it. Updated .