This document is a technical diagram and legend sheet for an Audio Visual (AV) system related to the Bethany Library project in Bethany, Oklahoma, prepared by WJHW and involving multiple engineering and architectural firms including Dewberry Engineers Inc., Alvine Engineering, and Smith Roberts Baldischwiler. The diagram provides comprehensive technical symbols, connection details, and signal flow information for audio and visual equipment installation, including standardized notations for devices such as microphones, speakers, transformers, connectors, and cable types.

The technical diagram includes detailed specifications for audio shield connections, cable preparation details, panel and device signal flow, and connectivity legends that outline various connector types (XLR, BNC, HDMI, RJ45, USB) and wiring configurations. The document is dated 06/01/2017 and appears to be part of the final construction documents for the Bethany Library's AV system, located at 6700 NW 35th Street in Bethany, Oklahoma, with project number 50085544. The detailed technical annotations suggest a comprehensive approach to designing and documenting the audio-visual infrastructure for the library's technological systems.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEV - ID

TYPE *

DEV - ID

TYPE *

PA - ID

TYPE *

SPEAKER - ID

TYPE *

SPEAKER - ID

TYPE *

ROOM / RACK / JUNCTION BOX

MIC 1

MIC

MIC 2

MIC

LINE 1

LINE

LINE 2

LINE

OUT

LINE

IN

MIC

TAP TAP

LINE 3

LINE

LINE 4

LINE

LINE 5

LINE

LINE 6

LINE

PARALLELED SPEAKERS DETAIL

FUNCTIONAL SYMBOL LEGEND

PLATE/PANEL SIGNAL FLOW DETAIL

DEVICE SIGNAL FLOW DETAL

SIGNAL / CONNECTION

(OPTIONAL)

SIGNAL / CONNECTION

(OPTIONAL)

DEVICE OUTPUT

(OPTIONAL)

DEVICE INPUT

(OPTIONAL)

TYPE #

DEVICE ID (OPTIONAL)

DEVICE NAME / ABBREVIATION

DASHED AREA DESCRIPTION

ML

SIGNAL / CONNECTION (OPTIONAL)

PLAN SYMBOL

ZZZ

AREA / ROOM

TYPE

CIRCUIT NUMBERCONSTANT VOLTAGE

TRANSFORMER/

TAP VALUE (W)

DEVICE

POWER AMPLIFIER

LOUDSPEAKER

POWERED LOUDSPEAKER

TO / FROM EXTERNAL SYSTEM

PATCH / CONNECTOR POINT

NORMALLED PATCH

SIGNAL CONTINUATION

NETWORK / FIBER PATCH POINT

NETWORK / FIBER THRU PATCH

CONNECTION POINT

NO CONNECTION

Y CONNECTION

MULTUPLE LINES

TRANSFORMER

AUTOFORMER

ANTENNA

MICROPHONE

LED / IR EMITTER

SCREW TERMINAL

POTENTIOMETER

SWITCH

Y XX Y XX Y XX ###Y XX ###

UNIQUE

IDENTIFIER

(IF USED)

DEVICE

DESTINATION

DEVICE

ORIGIN

UNIQUE

IDENTIFIER

(IF USED)

DEVICE

DESTINATION

DEVICE

ORIGIN

SHEET

REFERENCE

SIGNAL TO/FROM DEVICE

SHEET

REFERENCE

UNIQUE

IDENTIFIER

(IF USED)

SWITCH (MOMENTARY)

POLARITY

DETAIL/SHEET DETAIL/SHEET

DETAIL REFERENCE (OPTIONAL)

ML

PLAN SYMBOL

TO/FROM ON SHEET DEVICE TO/FROM OFF SHEET DEVICE

XLR-3F

PANEL SYMBOL LEGEND

XLR-3M XLR-4F XLR-4M XLR-5F XLR-5M

XLR-6F XLR-6M XLR-7M 1/4" PHONE 1/4" PHONE

COMBO

3MM

PHONE

BNC DISPLAY

PORT

FIBER

LC

HD15

(VGA)

HDMI RCA RJ45 USB/A USB/B NL4

XLR-7F

FIBER

ST

TUBING APPLIED OVER DRAIN

WIRE. ON TERMINATIONS

WHERE SHIELD IS FLOATING,

FOLD DRAIN WIRE BACK

UNDER HEAT SHRINK TUBING.

M-338 SIGNAL CONDUCTORS

S-338

SIGNAL WIRE

V-338

SIGNAL CONDUCTORS

V-338

DRAIN WIRE

TUBING APPLIED OVER DRAIN

WIRE. ON TERMINATIONS

WHERE SHIELD IS FLOATING,

FOLD DRAIN WIRE BACK

UNDER HEAT SHRINK TUBING.

HEAT SHRINK TUBING

HEAT SHRINK OR

ELASTIC TUBING

TYPICAL

CONNECTOR

MICROPHONE & LINE LEVEL CABLE

LOUDSPEAKER CABLE

MINI HIGH RESOLUTION COAXIAL CABLE

COAXIAL CABLE

CABLE LABEL

HEAT SHRINK TUBINGCABLE LABEL

HEAT SHRINK TUBINGCABLE LABEL

CABLE LABEL

ACTIVE BALANCED OUTPUT TO UNBALANCED INPUT

ACTIVE BALANCED OUTPUT TO ACTIVE BALANCED INPUT

UNBALANCED OUTPUT TO UNBALANCED INPUT

TRANSFORMER BALANCED OUTPUT TO UNBALANCED INPUT

TRANSFORMER BALANCED OUTPUT TO TRANSFORMER BALANCED INPUT

ACTIVE BALANCED OUTPUT TO TRANSFORMER BALANCED INPUT

UNBALANCED OUTPUT TO ACTIVE BALANCED INPUT

TRANSFORMER BALANCED OUTPUT TO ACTIVE BALANCED INPUT

UNBALANCED OUTPUT TO TRANSFORMER BALANCED INPUT

KEY PLAN

APPROVED BY

CHECKED BY

A

SHEET NO.

TITLE

DRAWN BY

DATE

PROJECT NO.

SCALE

SEAL

REVISIONS

23456

B

C

D

E

F

06/01/2017

50085544

B E

T H

A N

Y L

IB

R

A R

Y

C it y o f B e th a n y O k la h o m a

F

IN

A L

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

N

W th S tr e e t

B e th a n y O

K

No. Description Date

CC

BK

WJHW

Smith Roberts Baldischwiler

601 S.Lewis Ave.

Tulsa, OK 74104

Howell & Vancuren

1350 South Boulder Ave Suite 600 Tulsa, Oklahoma 74119

Dewberry Engineers Inc.

13431 Broadway Ext.

Suite 101 Oklahoma City, OK 73114

Alvine Engineering

3424 Midcourt Rd.

Suite 124 Carrollton, TX 75006

WJHW

Dewberry Architects Inc.

1350 South Boulder Ave Suite 600 Tulsa, OK 74119

2500 McGee Drive Suite 100 Norman, OK 73072

AV-600

DIAGRAM

NOTES AND

LEGENDS

NOT TO SCALE

Scale: N.T.S.

A4

AUDIO SHIELD CONNECTIONS

Scale:N.T.S.

A2

AV CABLE PREPARATION DETAILS

AV-600
AV-600 - DIAGRAM NOTES AND LEGENDS

File details come from the government source that posted it. Updated .