Attachment_I_-_Phase_2B_–_Office_Building_Renovation.pdf
PDF 20 MB Posted
- Attached to
- Haven on Vine Renovation Project State and local contract opportunity
- Solicitation number
- RFP2025-010
- Issued by
- Polk County, Lake Harbor CDP, Florida
About this file
The provided document is a comprehensive set of architectural and engineering design plans for Phase 2B of the Haven on Vine Renovation Project, prepared by Forefront Architecture & Engineering LLC for the City of Kissimmee, Florida. The plans comprehensively detail the renovation of an existing building into an office and administration space, including architectural, structural, electrical, plumbing, mechanical, and fire protection designs. The documents cover multiple aspects of the project, including site plans, floor plans, elevations, equipment schedules, specifications, and technical details for the annex building, with a focus on creating a functional office space that complies with current building codes and standards.
The design plans indicate a thorough approach to the renovation, addressing structural integrity, building systems, accessibility, and regulatory compliance. The project involves converting an existing storage building into a functional office space, with careful consideration of electrical, mechanical, and plumbing infrastructure. The plans show meticulous attention to detail, including specific requirements for materials, finishes, equipment installation, and adherence to the Florida Building Code 2023 edition. The design incorporates modern standards for energy efficiency, fire safety, and accessibility, with provisions for future maintenance and operational needs. The comprehensive nature of the documents suggests a complex renovation project that requires precise engineering and architectural expertise to transform the existing structure into a modern, functional office space.
View the file
Other files for this state and local contract opportunity
Show all 50
Haven on Vine Renovation Project has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BR
O N
SO
N D r.
BR
O N
SO
N D r.
H O
LL
YW
O O D S
T.
H O
LL
YW
O O D S
T.
BRONSON Dr.
M
EADOW
Dr
P E T T
IS
B L V D
WEST GUEST UNIT BUILDING
PARKING
PA
RK
IN
G
POOL
EA
ST
G
UES
T
UN
IT
B
UI
LD
IN
G
STORAGE
BUILDING
PA
RK
IN
G
PA
RK
IN
G
BU
IL
D
IN
G "C
BU
IL
D
IN
G "B
BU
IL
D
IN
G "A
BU
IL
D
IN
G "D
BU
IL
D
IN
G "E
BU
IL
D
IN
G "J
BU
IL
D
IN
G "I
BU
IL
D
IN
G "H
BU
IL
D
IN
G "G
BU
IL
D
IN
G "F
UILDING
V I N E S T R E E T
L A
V O
N
E M
O R
Y
M A
I N
S
T R
E E
T
B E
R M
U D
A
V
E N
U E
H I G H W A Y 1 9 2
1815 W. VINE ST.
C FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED.J:\City of Kissimmee\Jobs\Haven on Vine 2B\24-14068-02\Dwgs\Sheets\Architectural\A000 COVER SHEET ; Plot Date: Tuesday, February 25, 2025 ,2:00:57 PM; Plotted By: minelg
JO
B N
A M
E
S H
E E T N
A M
E
ISSUE - REVISION LOG
AR102538 - CA30900
H A V E N
O N
V
IN
E -2
B W
E S T V
IN
E S
T R
E E T K
IS
S
IM
M E E F L
S E A L
M A R K
D A T E
D E S C R
IP
T
IO
N
1230 Oakley Seaver Drive, Suite 100
Clermont, Florida 34711
888.850.FFAE (3323)
www.forefrontae.com
JOB # :
SHEET NUMBER :
24-14068
DATE : 02/28/2025
/2
/2
HAVEN ON VINE 2B
ENGINEEROWNER ARCHITECT MEP
Service Beyond Design
License No. AR102538 License No. CA30900
TO THE BEST OF THIS DESIGN PROFESSIONAL'S KNOWLEDGE, THESE PLANS AND SPECIFICATIONS
COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE SAFETY
STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH CHAPTER 553 AND
633 OF THE FLORIDA STATUTES AND MEET OR EXCEED THE REQUIREMENTS OF THE FLORIDA
BUILDING CODE - EXISTING BUILDING 8TH EDITION (2023), AS DEVELOPED AND MAINTAINED BY THE
FLORIDA BUILDING COMMISSION, AND ADMINISTERED AND ENFORCED BY LOCAL JURISDICTIONS.
Cabral Egineering Inc.
REVISION TABLE
REV #
REV
DATE
REV DESCRIPTION
ARCHITECTURAL SYMBOLS
DESIGN A NEW SERVICE CENTER TO BE LOCATED IN THE
EXISTING LANDRY/UTILITY BUILDING. ALSO UPGRADE
EXTERIOR OF BUILDING.
R - 2
V - B
THIS PROJECT MUST COMPLY WITH THE FOLLOWING CODES:
NFPA 70-17 NATIONAL ELECTRIC CODE (NEC)
FLORIDA BUILDING CODE - EXISTING BUILDING 8TH EDITION
FLORIDA BUILDING CODE 2023 - MECHANICAL (8TH EDITION)
FLORIDA BUILDING CODE 2023 - PLUMBING (8TH EDITION)
FLORIDA BUILDING CODE 2023 - ENERGY CONSERVATION (8TH
EDITION)
FLORIDA BUILDING CODE 2023 - FUEL AND GAS (8TH EDITION)
FLORIDA FIRE PREVENTION CODE 2023 (8TH EDITION)
FLORIDA BUILDING CODE - EXISTING RESIDENTIAL BUILDING
8TH EDITION (2023)
NFPA LATEST EDITION NATIONAL ELECTRIC CODE (NEC)
SPRINKLER
EXISTING FIRST FLOOR PLAN AREA
NAME AREA SPACE
EXISTING FIRST FLOOR
SCALE:
SITE LOCATION
N/A
SCALE:
BUILDING
N/A
SCALE:
VICINITY MAP
N/A
SCALE:
MAP
N/A
TOTAL 946
NO ADDITIONAL SQUARE
FOOTAGE ADDED
PHASE 2B -
C
IT
Y O
F K
IS
S
IM
M E E J
U R
IS
D
IC
T
IO
N S
U B M
IT
T A L
= 34###
# SECTION INDICATOR
SHEET NUMBER
# DETAIL NUMBER
SHEET NUMBER
REFERENCE NUMBER
REVISION NUMBER
REFER TO TITLE SHEET
SHEET LIST TABLE
SHEET
SHEET TITLE
Rev_n o
Rev_Dat e
A000 COVER SHEET 0 00/00/00
A001 GENERAL NOTES 0 00/00/00
A002 OVERALL SITE PLAN - EXISTING 0 00/00/00
A003 OVERALL SITE PLAN - PROPOSED 0 00/00/00
A004 ANNEX BUILDING - LIFE SAFETY PLAN 0 00/00/00
A100 ANNEX BUILDING - EXISTING AND DEMOLITION 0 00/00/00
A101 ANNEX BUILDING - PROPOSED FLOOR PLAN 0 00/00/00
A102 ANNEX BUILDING RESTROOMS - ENLARGED AND
ELEVATIONS
0 00/00/00
A200 ELEVATIONS - EXISTING AND DEMOLITION 0 00/00/00
A201 ELEVATIONS - PROPOSED 0 00/00/00
A300 ROOF PLAN - EXISTNG AND PROPOSED 0 00/00/00
A400 ANNEX BUILDING - REFLECTED CEILING PLAN 0 00/00/00
A500 DOOR AND FINISHES SCHEDULES 0 00/00/00
S001 STRUCTURAL GENERAL NOTES 0 00/00/00
S002 STRUCTURAL GENERAL NOTES 0 00/00/00
S100 FOUNDATION PLAN - PHASE 2B 0 00/00/00
S200 ROOF FRAMING PLAN - PHASE 2B 0 00/00/00
SD100 CHARTS AND SCHEDULES 0 00/00/00
SD200 FOUNDATION DETAILS 0 00/00/00
SD300 FRAMING DETAILS - ROOF 0 00/00/00
0 00/00/00FS100 FIRE PROTECTION GENERAL NOTES, LEGENDS,
ABBREVIATION AND INDEX
0 00/00/00FS101 FIRE PROTECTION SPECIFICATIONS
FS200 FIRE SPRINKLER FLOOR PLAN
FS300 FIRE SPRINKLER DETAILS
M100 MECHANICAL LEGENDS, ABBREVIATIONS AND INDEX
M101 MECHANICAL SPECIFICATIONS
M200 MECHANICAL FLOOR PLAN - DUCTWORK/PIPING
M300 MECHANICAL EQUIPMENT SCHEDULE
M400 MECHANICAL DETAILS
0 00/00/00
0 00/00/00
0 00/00/00
0 00/00/00
0 00/00/00
0 00/00/00
0 00/00/00
0 00/00/00
E001 ELECTRICAL - GENERAL
E101 ELECTRICAL AND TELECOMMUNICATIONS SITE PLAN
E203
E801
E901 ELECTRICAL DETAILS
E902 ELECTRICAL DETAILS
0 00/00/00
0 00/00/00
0 00/00/00
0 00/00/00
0 00/00/00
0 00/00/000 00/00/00
0 00/00/00
0 00/00/00
00/00/00
E802 ELV DIAGRAMS AND ELEVATIONS 0 00/00/00
ELECTRICAL PLANS
P100 PLUMBING LEGENDS, ABBREVIATIONS AND INDEX
P101 PLUMBING SPECIFICATIONS
P200 PLUMBING FLOOR PLAN - RISER DIAGRAM
P300 PLUMBING FIXTURE SCHEDULE AND DETAILS
0 00/00/00
0 00/00/00
0 00/00/00
ELECTRICAL DIAGRAMS AND SCHEDULES
GENERAL NOTES PAINT & WALL COVERING NOTES
FLOORING NOTES
CLEANING NOTES
DEMOLITION NOTES
CEILING NOTES
PAINT & WALL COVERING NOTES
PATCHING NOTES
1. THESE DOCUMENTS HAVE BEEN PREPARED EXPRESSLY FOR USE BY
FOR THE PURPOSE OF BUILDING.
2. ANY ADDITIONAL USE OF THESE DOCUMENTS FOR ANY REASON OTHER
THAN THAT MENTIONED ABOVE MUST BE AUTHORIZED IN WRITING BY
THE COPYRIGHT HOLDER.
3. THESE DRAWINGS REFLECT DESIGN INTENT.
4. THESE DRAWINGS, AS LISTED IN THE DRAWING INDEX, ALONG WITH THE
SPECIFICATIONS & CONTRACT FOR CONSTRUCTION, CONSTITUTE THE
INSTRUMENTS OF SERVICE AND ARE CONSIDERED A SINGLE ENTITY. THE
CONTRACTOR IS THEREFORE BOUND BY ALL INFORMATION INCLUDED.
5. ONLY DRAWINGS MARKED 'ISSUED FOR CONSTRUCTION'
SHALL BE USED AS A BASIS FOR CONSTRUCTION.
6. THE TERM 'CONTRACTOR' IN THE PLANS SHALL REFER TO THE GENERAL
CONTRACTOR. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL
CONTRACTOR TO COORDINATE THE SUBCONTRACTOR WORK WITH
THESE PROJECT DOCUMENTS. CONTRACTOR SHALL PROVIDE A LIST OF
ALL SUB-CONTRACTORS TO THE CONSTRUCTION PROJECT MANAGER.
7. CONTACT CONSTRUCTION PROJECT MANAGER FOR
COORDINATION OF STAGING AND REFUSE REMOVAL PRIOR TO SIGNING
THE CONTRACT FOR CONSTRUCTION. ANY ADJUSTMENT IN THE
CONTRACT AMOUNT OR DURATION DUE TO REQUIREMENTS
SHALL BE MADE PRIOR TO CONTRACT EXECUTION.
8. ALL ITEMS SHOWN ARE NEW TO BE PROVIDED & INSTALLED BY G.C.
UNLESS NOTED OTHERWISE.
9. DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS TAKE PRECEDENT.
LARGE SCALE DRAWINGS TAKE PRECEDENCE OVER SMALL SCALE
DRAWINGS. DETAILS TAKE PRECEDENCE OVER ALL.
10. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS AND
CONDITIONS PRIOR TO BID AND CONSTRUCTION. CONTRACTOR SHALL
NOTIFY THE CONSTRUCTION PROJECT MANAGER AND THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OR OMISSIONS PRIOR
TO PROCEEDING WITH ANY WORK.
11. FOR BIDDING PURPOSES; WHERE CONFLICTS EXIST BETWEEN DRAWING
DETAILS & SPECIFICATIONS, THE MORE STRINGENT SPECIFICATION
SHALL APPLY.
12. PRIOR TO SUBMITTING A PROPOSAL, ALL CONTRACTORS SHALL VISIT
THE SITE TO FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND
THE NATURE AND SCOPE OF THE WORK. THE SUBMISSION OF A
PROPOSAL SHALL BE CONSTRUED AS EVIDENCE THAT SUCH A SITE VISIT
HAS BEEN MADE, AND LATE CLAIMS FOR LABOR, EQUIPMENT OR
MATERIALS REQUIRED FOR DIFFICULTIES ENCOUNTERED, WHICH COULD
HAVE BEEN FORESEEN HAD SUCH AN EXAMINATION BEEN MADE, WILL
NOT BE RECOGNIZED.
13. THE GENERAL CONTRACTOR / SUB-CONTRACTOR SHALL OBTAIN AND
PAY FOR ALL THE LEGALLY REQUIRED APPROVAL AND PERMITS
NECESSARY FOR THE EXECUTION AND COMPLETION OF THE FORWARD
COPIES TO THE TENANT CONSTRUCTION PROJECT MANAGER .
14. ALL WORK PERFORMED BY THE CONTRACTOR / SUB-CONTRACTOR
SHALL CONFORM TO THE REQUIREMENTS OF THE MUNICIPAL, LOCAL,
AND STATE AND FEDERAL LAWS, AS WELL AS ANY OTHER GOVERNING
REQUIREMENTS, INCLUDING LANDLORD REQUIREMENTS, WHETHER OR
NOT SPECIFIED ON THE DRAWINGS.
15. WHERE THE CONTRACT NOTES OR DRAWINGS CALL FOR ANY WORK OR
A MORE STRINGENT NATURE THAN THAT REQUIRED BY THE BUILDING
CODE OR ANY OTHER DEPARTMENT HAVING JURISDICTION OVER THE
WORK, THE WORK OF THE MORE STRINGENT NATURE CALLED FOR BY
THE CONTRACT NOTES OR DRAWINGS SHALL BE FURNISHED IN ALL
CASES.
16. ALL CONTRACTORS SHALL CONTACT THE BUILDING
MANAGEMENT/LANDLORD TO DETERMINE THE RULES OF THE BUILDING
OWNER FOR CONSTRUCTION AND DELIVERY OF EQUIPMENT AND
MATERIALS.
17. PRIOR TO BEGINNING ANY WORK, THE GENERAL CONTRACTOR SHALL
FURNISH THE CONSTRUCTION PROJECT MANAGER WITH A
CONSTRUCTION SCHEDULE SHOWING THE CHRONOLOGICAL PHASES OF
HIS WORK AND ALL RELATED WORK FOR THE COMPLETION OF THE
PROJECT. THIS SCHEDULE SHALL INDICATE ALL ORDERING LEAD TIMES,
LENGTH OF TIME FOR EACH PHASE AND THE PROJECTED START AND
COMPLETE DATES.
18. IT IS ASSUMED THAT THE G.C. SHALL PERFORM THE WORK AS
ILLUSTRATED WITHIN THE PERMITTED DRAWINGS. THE CONTRACTOR
SHALL NOTIFY THE ARCHITECT IN THE EVENT THAT EXISTING SITE
CONDITIONS PREVENT THE WORK FROM BEING COMPLETED AS
ILLUSTRATED HEREIN SO THAT ANY MODIFICATIONS TO THE
CONSTRUCTION DOCUMENTS (IF NECESSARY) CAN BE MADE. ANY
DEVIATIONS FROM THE PERMITTED DRAWINGS WILL NOT BE
ACCEPTABLE, AND THE CONTRACTOR SHALL RECONFIGURE THE WORK
AT HIS OWN EXPENSE, AS REQUIRED TO BE IN CONFORMANCE WITH THE
PERMITTED DOCUMENTS. THE ARCHITECT WILL NOT ACCEPT, CERTIFY,
OR DOCUMENT ANY WORK THAT DOES NOT CONFORM TO THE
PERMITTED DOCUMENTS FOR THE PURPOSES OF OBTAINING ANY
ADDITIONAL MUNICIPAL APPROVAL REQUIRED DUE TO UNAUTHORIZED
REVISIONS.
19. THE GENERAL CONTRACTOR SHALL MAINTAIN A CURRENT AND
COMPLETE SET OF CONSTRUCTION DRAWINGS ON SITE THROUGHOUT
THE DURATION OF CONSTRUCTION FOR USE BY ALL TRADES.
20. ALL DEBRIS SHALL BE REMOVED FROM THE PREMISES, AND WORK
AREAS SHALL BE LEFT IN A CLEAN CONDITION ON A DAILY BASIS.
21. THE GENERAL CONTRACTOR SHALL EXERCISE STRICT DUST
CONTAINMENT CONTROL OVER THE JOB SITE TO PREVENT DUST FROM
ESCAPING.
22. THE GENERAL CONTRACTOR SHALL PROPERLY PROTECT THE GENERAL
BUILDING AREAS AND ANY ADJOINING PROPERTY OR WORK FROM
DAMAGE DURING CONSTRUCTION, AND SHALL PATCH OR REPLACE ANY
DAMAGED WORK OR MATERIALS WITHOUT DELAY.
23. ANY DAMAGE BY G.C. OR SUBCONTRACTOR TO EXISTING ASPHALT
PAVEMENT AND/OR EXISTING LANDSCAPING OUTSIDE OF
CONSTRUCTION LIMIT LINE SHALL BE REPAIRED AT NO COST TO OWNER OR TENANT.
24. DURING THE ENTIRE PERIOD OF DEMOLITION AND CONSTRUCTION. ALL
REQUIRED EXITS AND EGRESS PATHWAYS SHALL BE CONTINUOUSLY
MAINTAINED FREE FROM ALL OBSTRUCTIONS AND IMPEDIMENTS IN THE
CASE OF A FIRE OR OTHER EMERGENCY. ALL EXISTING EXIT LIGHTING,
FIRE PROTECTIVE DEVICES AND ALARMS SHALL BE CONTINUOUSLY
MAINTAINED.
25. NO MATERIALS SHALL BE STORED ON PUBLIC PROPERTY UNLESS AN
ENCROACHMENT PERMIT IS FIRST OBTAINED FROM THE PUBLIC WORKS
DEPT.
26. EACH TRADE SHALL PROVIDE CAULKING OR SEALANT WHERE REQUIRED.
27. PROVIDE STRUCTURAL SUPPORTS AS REQUIRED AT ALL WALL MOUNTED
EQUIPMENT, CABINETS, PLUMBING AND LIGHT FIXTURES.
28. MANUFACTURER'S NAME, TRADEMARK, LOGOS, ETC., SHALL NOT BE
VISIBLE TO THE PUBLIC.
29. ALL FLOOR SLAB CUTTING, TRENCHING AND REMOVAL SHALL BE
REPLACED WITH THE SAME MATERIAL IN THE SAME THICKNESS OF THE
ADJACENT FLOOR MATERIAL. ADDITIONAL CONCRETE PATCHING SHALL
BE DOWELED INTO THE ADJACENT CONCRETE SLAB TO MINIMIZE
DIFFERENTIAL SETTLEMENT OF THE FLOOR SYSTEM.
30. ALL ROOF PENETRATIONS ARE TO BE PERFORMED BY
PROJECT/CONSTRUCTION MANAGER'S ROOFING CONTRACTOR.
CONTACT PROJECT/CONSTRUCTION MANAGER TO COORDINATE.
31.ALL WALL, FLOOR, CEILING, ETC. PENETRATIONS ARE TO BE DRAFT OR
FIRESTOPPED (WHERE REQUIRED TO MATCH FIRE COMPARTMENTS). ASSURE NO AIR
LEAKAGE, PARTICULARLY WHEN A PLENUM IS IN USE.
1. THE GENERAL CONTRACTOR SHALL DO ALL CUTTING, FITTING, AND
PATCHING WORK THAT MAY BE REQUIRED TO MAKE ALL PARTS COME
TOGETHER PROPERLY AND FIT TO RECEIVE OR BE RECEIVED BY WORK
OF OTHER CONTRACTORS SHOWN UPON OR REASONABLY IMPLIED BY
THE DRAWINGS AND NOTES.
2. THE GENERAL CONTRACTOR SHALL PROVIDE ALL FLOOR CUT-OUTS AND
PATCHING REQUIRED FOR THE INSTALLATION OF ALL WORK.
3. THE GENERAL CONTRACTOR SHALL SURVEY ALL EXISTING FINISHED
SURFACES INCLUDING CORNER BEADS, STOPS, ETC. FOR CHIPS, CRACK
HOLES, DAMAGED SURFACES AND DEFECTS AND REPAIR SAME TO THE
SATISFACTION OF PROJECT MANAGER.
4. WHERE DOOR BUCKS HAVE BEEN REMOVED, REPAIR GAPS AND
SURFACES TO ACHIEVE A CLASS I FINISH TO THE SATISFACTION OF
CONSTRUCTION PROJECT MANAGER.
5. THE GENERAL CONTRACTOR SHALL PROVIDE METAL LATH OVER ALL NEW
CONDUIT CHASES IN MASONRY PARTITIONS.
6. ALL DAMAGED EXISTING AREAS TO REMAIN AND EXISTING AREAS
AFFECTED BY DEMOLITION OR NEW CONSTRUCTION WORK SHOWN ON
DRAWINGS SHALL BE PATCHED AS REQUIRED TO MATCH IMMEDIATE
EXISTING ADJACENT AREAS IN MATERIALS, FIRE RATING, FINISH AND
COLOR UNLESS OTHERWISE NOTED.
7. ALL FIRE PROOFING REMOVED FROM COLUMNS AND BEAMS DURING THE
COURSE OF CONSTRUCTION SHALL BE REPLACED WITH THE SAME
MATERIAL AND RATING AS THAT WHICH WAS REMOVED.
1. UNLESS OTHERWISE SPECIFIED, ALL AREAS ARE TO BE PAINTED IN
ACCORDANCE WITH FINISH PLANS.
2. WALLS SHALL INCLUDE SURFACES FROM FLOOR TO CEILING, INCLUDING
PILASTERS, FACIAS, JAMBS BUCKS, REVEALS, RETURNS, AND ALL
VERTICAL SURFACES NOT INCLUDED IN CEILING.
3. PAINT COLORS SHALL BE SPECIFIED BY THE OWNER AND THE GENERAL
CONTRACTOR SHALL SUBMIT 3 SAMPLES (12" X 12") FOR REVIEW BY THE
OWNER / ARCHITECT.
4. ALL WALLS AND CEILINGS SHALL BE PROPERLY PREPARED, SPACKLE,
SANDED, ETC. TO PROVIDE A PERFECTLY SMOOTH FINISH AND SURFACE
READY FOR PRIME AND PAINT.
5. ALL EXISTING LOOSE PAINT SHALL BE REMOVED AND SPACKLE OR
PLASTER PATCHED.
6. ALL EXISTING UNEVENNESS IN ALL PARTITIONS SHALL BE SANDED OR
CHIPPED AWAY AND SURFACES PLASTER-PATCHED OR SPACKLE TO
INSURE A PERFECTLY EVEN SURFACE.
7. THE CONTRACTOR SHALL REMOVE ALL ELECTRICAL SWITCH PLATES AND
OUTLET PLATES, SURFACE HARDWARE, ETC., PRIOR TO PAINTING,
PROTECTING AND REPLACING SAME WHEN PAINTING HAS BEEN
COMPLETED. HE SHALL REMOVE ALL PAINT FROM WHERE IT HAS SPILLED,
SPLASHED OR SPLATTERED ON SURFACES, INCLUDING BUT NOT LIMITED
TO LIGHT FIXTURES, DIFFUSERS, REGISTERS AND SLAB FITTINGS, ETC.
8. THE CONTRACTOR SHALL USE A LATEX BASE PAINT IN COLORS AND
FINISHES SELECTED BY THE ARCHITECT. HE SHALL PROPERLY PREPARE
ALL SURFACES TO RECEIVE ONE (1) PRIME COAT AND TWO (2) FINISH
COAST OF PAINT IN COLOR SELECTED BY THE ARCHITECT.
9. THE CONTRACTOR SHALL EXAMINE ALL AREAS OF CONSTRUCTION AFTER
COMPLETION OF WORK BY ALL TRADES (INCLUDING TELEPHONE
INSTALLATION, FLOORING, ETC.) AND INDICATE ALL NECESSARY
"TOUCH-UP" PAINTING AND/OR PATCHING.
11. IT IS THE INTENT OF THE DRAWINGS THAT ALL EXPOSED SURFACES
RECEIVE FINISHES AS INDICATED ON THE DRAWINGS OR IN THE
SPECIFICATIONS UNLESS SPECIFICALLY NOTED OTHERWISE.ANY
SURFACES WHICH DO NOT HAVE A SPECIFIC FINISH NOTED OR ARE
NOTED TO REMAIN UNFINISHED SHALL BE BROUGHT TO THE ATTENTION
OF THE ARCHITECT AND FINISHED PER THE ARCHITECT'S INSTRUCTION.
12. PAINT FRONT SIDE, BACK SIDE AND DOOR EDGES AT STRIKE SIDE AND
HINGE SIDE. LEAVE TOP AND BOTTOM UNPAINTED TO PREVENT
WARPING.
13. PAINT ALL METAL ACCESS DOORS AND ACCESS PANELS TO MATCH
ADJACENT WALL OR CEILING FINISH. GRAPHICS ON DOOR OR PANEL (IF
ANY) ARE TO BE REPAINTED/RE-APPLIED TO MATCH EXISTING, IF
APPLICABLE.
1. FACIAS OR ANY BREAK IN THE CEILING HEIGHTS CREATED BY THE
INSTALLATION AND/OR ALTERATION OF HEATING, VENTILATING, AIR
CONDITIONING OF MECHANICAL DUCTS, PIPING OR OTHER EQUIPMENT
SHALL BE FORMED OF GYPSUM WALLBOARD ON FURRING CHANNELS.
HUNG CEILING HEIGHTS SHALL BE AS SHOWN ON ARCHITECTURAL
DRAWINGS AND DETAILS.
2. ANY DEVIATION FROM HEIGHTS SHOWN WILL BE SUBMITTED TO THE
CONSTRUCTION AND ARCHITECT PROJECT MANAGER FOR REVIEW.
3. THE GENERAL CONTRACTORS CEILING CONTRACTOR SHALL CLOSELY
COORDINATE HIS WORK WITH THAT OF THE FIXTURE, PLUMBING HVAC
ELECTRICAL CONTRACTORS AND THE TELEPHONE COMPANY WHENEVER
THEIR RESPECTIVE WORK IS CONTIGUOUS.
4. THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL CEILING
ACCESS PANELS IN GYPSUM BOARD CEILINGS AS REQUIRED TO FURNISH
ACCESS TO ALL AIR HANDLING UNITS, PHONE AND ELECTRICAL
CONTROLS AS REQUIRED BY LOCAL BUILDING CODES. COORDINATE
LOCATIONS WITH CONSTRUCTION PROJECT MANAGER AND ARCHITECT PRIOR TO FINAL
INSTALLATION.
5. PRIOR TO CLOSING UP ANY CEILING, ALL PLENUM SYSTEMS (HVAC,
PLUMBING AND ELECTRIC) SHALL BE INSPECTED AND WHERE REQUIRED,
TESTED BY CONTRACTOR'S ENGINEERS AND BY AUTHORITIES HAVING
JURISDICTION TO INSURE THEIR PROPER INSTALLATION AND FUNCTION.
6. THE CEILING TILE JOINTS SHALL BE ALIGNED PERFECTLY WITH RECESSED
LIGHTING FIXTURES.
7. ALL JOINTS IN THE TILE FIELD SHALL BE SQUARE, LEVEL, AND PERFECTLY
ALIGNED WITH EACH OTHER AND WITH THE RECESSED LIGHTING
FIXTURES.
8. CEILINGS IN CLOSETS SHALL BE OF THE SAME HEIGHTS AND
CONSTRUCTION AS THAT OF ADJOINING SPACE, EXCEPT AS OTHERWISE
NOTED.
9. THE GENERAL CONTRACTOR WILL NOT BE ENTITLED TO EXTRAS FOR
OPENING ANY CEILING BECAUSE OF TELEPHONE INSTALLATION,
SECURITY SYSTEMS OR COMPUTER DATA SYSTEMS.
10. PROVIDE BLOCKING/BACKING AND CEILING REINFORCEMENT FOR ALL
CEILING MOUNTED ITEMS, (PLASMA SCREENS, ETC.).
1. THE GENERAL CONTRACTOR SHALL FLASH PATCH ALL CRACKS, HOLES
OR OTHER IMPERFECTIONS (PROJECTIONS SHALL BE REMOVED AND
PATCHED TO PROVIDE A CONTINUOUS SMOOTH FLOOR SURFACE). LEVEL
NOT TO EXCEED 1/4" IN 10-0" NON-CUMULATIVE.
2. THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT AFTER FLOOR
PATCHING IS DONE AND RECEIVE
THEIR REVIEW PRIOR TO INSTALLATION OF FINISHED FLOORING.
3. ALL NEW FLOORING IS TO BE INSTALLED BY GENERAL CONTRACTOR AND
SHALL BE AS SPECIFIED ON THE ARCHITECT'S CONSTRUCTION
DOCUMENTS.
4. ALL WORKMANSHIP SHALL BE OF THE BEST QUALITY AND WHEN THE
WORK IS COMPLETE, IT SHALL BE FREE FROM BUCKLES, BUBBLES, OPEN
JOINTS OR OTHER IMPERFECTIONS. SEAMS SHALL BE KEPT IN ACCURATE
ALIGNMENT ALONG BOTH COORDINATES. TILE HAVING CHIPPED OR
ROUNDED CORNERS WILL BE REJECTED AND IF LAID, SHALL BE REMOVED
AND REPLACED WITH ACCEPTABLE TILE.
5. SPACES BEING SURFACED SHALL BE CLOSED TO TRAFFIC AND OTHER
WORK DURING THE LAYING OF FLOORING. TILE FLOORS SHALL BE
COVERED AFTER INSTALLATION FOR PROTECTION.
6. UPON COMPLETION, ALL WORK SHALL BE CLEANED BY THE CONTRACTOR
REMOVING ALL SPOTS OF ADHESIVE AND SURFACE STAINS AND ALL
SCRAPS. CARTONS AND CONTAINERS SHALL BE REMOVED FROM THE
BUILDING.
7. THE GENERAL CONTRACTOR TO COORDINATE ALL FLOORING
CONTRACTORS INVOLVED TO ASSURE FLUSH INSTALLATION OF ALL
VARYING FLOOR MATERIALS USED. ALL TRANSITION METHODS TO BE
APPROVED BY THE ARCHITECT .
1. THE NEW ITEMS INSTALLED BY THE GENERAL CONTRACTOR IN ADDITION
TO BEING AMPLY PROTECTED THROUGHOUT THE PERIOD OF
CONSTRUCTION SHALL BE THOROUGHLY CLEANED TO THE SATISFACTION
OF THE PRIOR TO TURNOVER.
2. ALL CONSTRUCTION ACTIVITY IS TO NOT INTERFERE WITH THE DAILY OPERATING
OF THE EXISTING OFFICE BUILDING.
1. COORDINATE ALL DEMOLITION WITH FACILITIES.
2. ALL DEMOLITION MUST BE PERFORMED IN A MANNER TO CONTAIN DUST AND
PARTICLES.
3. AREA MUST REMAIN CLEAN, SAFE, AND OCCUPABLE.
4. ALL SYSTEMS MUST REMAIN FUNCTIONAL DURING DEMOLITION.
C FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED.J:\City of Kissimmee\Jobs\Haven on Vine 2B\24-14068-02\Dwgs\Sheets\Architectural\A001 GENERAL NOTES ; Plot Date: Monday, February 17, 2025 ,5:11:00 PM; Plotted By: minelg
JO
B N
A M
E
S H
E E T N
A M
E
ISSUE - REVISION LOG
AR102538 - CA30900
H A V E N
O N
V
IN
E -2
B W
E S T V
IN
E S
T R
E E T K
IS
S
IM
M E E F L
S E A L
M A R K
D A T E
D E S C R
IP
T
IO
N
1230 Oakley Seaver Drive, Suite 100
Clermont, Florida 34711
888.850.FFAE (3323)
www.forefrontae.com
JOB # :
SHEET NUMBER :
24-14068
DATE : 02/28/2025
/2
/2
C
IT
Y O
F K
IS
S
IM
M E E J
U R
IS
D
IC
T
IO
N S
U B M
IT
T
L
BR
O N
SO
N D r.
BR
O N
SO
N D r.
H O
LL
YW
O O D S
T.
H O
LL
YW
O O D S
T.
BRONSON Dr.
M
EADOW
Dr
P E T T
IS
B L V D
V I N E S T R E E T - H I G H W A Y 1 9 2
PARKING
PA
RK
IN
G
EA
ST
G
UE
ST
U
N
IT
B
UI
LD
IN
G
STORAGE
BUILDING
PA
RK
IN
G
BU
IL
D
IN
G B"
BU
IL
D
IN
G E"
WEST GUEST UNIT BUILDING
PA
RK
IN
G
POOL
BU
IL
D
IN
G "F
BU
IL
D
IN
G "A
BU
IL
D
IN
G J"
BU
IL
D
IN
G "I
BU
IL
D
IN
G "C
BU
IL
D
IN
G "H
BU
IL
D
IN
G D
BU
IL
D
IN
G "G
AREA OF WORK FOR
PHASE 2A TO BE FILED
UNDER A SEPARATE
APPLICATION
N O
T IN
S
C O
P E O
F
W O
R K
AREA OF WORK FOR
PHASE 1B TO BE FILED
UNDER A SEPARATE
APPLICATION
NOT IN SCOPE OF
WORK
NOT IN SCOPE OF
WORK
NOT IN SCOPE OF
WORK
NOT IN SCOPE OF
WORK
AREA OF WORK FOR
PHASE 1A TO BE FILED
UNDER A SEPARATE
APPLICATION
NOT IN SCOPE OF
WORK
NOT IN SCOPE OF
WORK
NOT IN SCOPE OF
WORK
SCALE:
OVERALL SITE PLAN - EXISTING
1/32"=1'-0"
C FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED.J:\City of Kissimmee\Jobs\Haven on Vine 2B\24-14068-02\Dwgs\Sheets\Architectural\A002 OVERALL SITE PLAN - EXISTING ; Plot Date: Monday, February 17, 2025 ,5:11:05 PM; Plotted By: minelg
JO
B N
A M
E
S H
E E T N
A M
E
ISSUE - REVISION LOG
AR102538 - CA30900
H A V E N
O N
V
IN
E -2
B W
E S T V
IN
E S
T R
E E T K
IS
S
IM
M E E F L
S E A L
M A R K
D A T E
D E S C R
IP
T
IO
N
1230 Oakley Seaver Drive, Suite 100
Clermont, Florida 34711
888.850.FFAE (3323)
www.forefrontae.com
JOB # :
SHEET NUMBER :
24-14068
DATE : 02/28/2025
/2
/2
C
IT
Y
O F
K
IS
S
IM
M E
E J
U R
IS
D
IC
T
IO
N
S U
B M
IT
T
EXISTING
POOL
BR
O N
SO
N D r.
BR
O N
SO
N D r.
H O
LL
YW
O O D S
T.
H O
LL
YW
O O D S
T.
BRONSON Dr.
M
EADOW
Dr
P E T T
IS
B L V D
V I N E S T R E E T - H I G H W A Y 1 9 2
PARKING
PA
RK
IN
G
EA
ST
G
UE
ST
U
N
IT
B
UI
LD
IN
G
ANNEX
BUILDING
PA
RK
IN
G
BU
IL
D
IN
G "C
BU
IL
D
IN
G B"
BU
IL
D
IN
G "A
BU
IL
D
IN
G D
BU
IL
D
IN
G E"
BU
IL
D
IN
G J"
BU
IL
D
IN
G "I
BU
IL
D
IN
G "H
BU
IL
D
IN
G "G
BU
IL
D
IN
G "F
WEST GUEST UNIT BUILDING
CONC. W
ALKW
AY
AREA OF WORK FOR PHASE
2A TO BE FILED UNDER A
SEPARATE APPLICATION
N O T
IN
S
CO
PE
O F
W O
RK
AREA OF WORK FOR PHASE
1B TO BE FILED UNDER A
SEPARATE APPLICATION
NOT IN SCOPE OF
WORK
NOT IN SCOPE OF
WORK
NOT IN SCOPE OF
WORK
NOT IN SCOPE OF
WORK
AREA OF WORK FOR PHASE
1A TO BE FILED UNDER A
SEPARATE APPLICATION
NOT IN SCOPE OF
WORK
NOT IN SCOPE OF
WORK
NOT IN SCOPE OF
WORK
C FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED.J:\City of Kissimmee\Jobs\Haven on Vine 2B\24-14068-02\Dwgs\Sheets\Architectural\A003 OVERALL SITE PLAN - PROPOSED ; Plot Date: Monday, February 17, 2025 ,5:11:09 PM; Plotted By: minelg
JO
B N
A M
E
S H
E E T N
A M
E
ISSUE - REVISION LOG
AR102538 - CA30900
H A V E N
O N
V
IN
E -2
B W
E S T V
IN
E S
T R
E E T K
IS
S
IM
M E E F L
S E A L
M A R K
D A T E
D E S C R
IP
T
IO
N
1230 Oakley Seaver Drive, Suite 100
Clermont, Florida 34711
888.850.FFAE (3323)
www.forefrontae.com
JOB # :
SHEET NUMBER :
24-14068
DATE : 02/28/2025
/2
/2
C
IT
Y O
F K
IS
S
IM
M E E J
U R
IS
D
IC
T
IO
N S
U B M
IT
T A L
SCALE:
OVERALL SITE PLAN - PROPOSED
1/32"=1'-0"
TRAVEL PATH
38'
MERGE
P1 & P2
TRAVEL PATH
23'
TRAVEL
PATH
5'
S-1
W
M
A
74"
S-2
E-01
MERGE
P2 & P3
S-2
34 SF
OCCUPANTS 1
733 SF
OCCUPANTS 5
FEC
20 SF
OCCUPANTS 1
S-3
W
M
A
50"
E-02
TRAVEL
PATH
5'
OCCUPANCY CLASSIFICATION AND LOAD - ANNEX BUILDING
(FBC TABLE 1004.5)
FUNCTION OF SPACE HATCH
OPEN OFFICE SPACE
FUNCTION OF SPACE
OCCUPANCY CATEGORY
S.F. OCCUPANT LOAD
FACTOR
NUMBER OF
OCCUPANTS
B - BUSINESS
733 150 GROSS
ANNEX BUILDING PLUMBING FIXTURES (FBC TABLE 2902.1)
BUSINESS GROUP B
OCCUPANTS = 6 PLUS 1
TOTAL FIXTURES
REQUIRED
MALE FEMALE TOTAL FIXTURES
PROVIDED
OCCUPANT LOAD
WATER CLOSET (1/25) REQUIRED
LAVATORY (1/40) REQUIRED
DRINKING NOT REQUIRED
FOUNTAIN
SERVICE SINK LESS THAN 15
O.L. NOT REQUIRED
WATER CLOSET
LAVATORY
0.11
1 1
1 1
0.12
0.08
0.12
0.08
MALE FEMALE
FIRE RISER ROOM
S1 - MODERATE
HAZARD STORAGE
300 GROSS 120
ELECTRICAL ROOM
S1 - MODERATE
HAZARD STORAGE
300 GROSS 134
INDICATES START OF LONGEST TRAVEL PATH INSIDE OF BUILDING
INDICATES END OF TRAVEL PATH OUTSIDE OF DOOR
INDICATES TRAVEL PATH NUMBER
INDICATES TRAVEL PATH DISTANCE
TRAVEL PATH, ARROWS INDICATE DIRECTION
CLEAR WIDTH OF OPENING
EGRESS USER FACTOR
INDICATES CLEAR WIDTH OF CORRIDOR IN INCHES
MERGE POINTS OF ONE OR MORE EXIT TRAVEL PATHS
FIRE EXTINGUISHER CABINET, WALL-MOUNTED
5 LB, 2A-10B:C, MULTI-PURPOSE EXTINGUISHER.
TOP OF EXTINGUISHER SHALL NOT BE MORE THAN 5' AFF
AND THE BOTTOM SHALL NOT BE LESS THAN 4" AFF
SMOKE DETECTOR, CEILING-MOUNTED
INTRUSION / BURGLAR ALARM PANEL
FIRE EXTINGUISHER CABINET, WALL-MOUNTED
5 LB
TOP OF EXTINGUISHER SHALL NOT BE MORE THAN 5' AFF
AND THE BOTTOM SHALL NOT BE LESS THAN 4" AFF
COMBINATION EXIT LIGHT AND EMERGENCY LIGHT
DENOTES DIRECTION OF SIGN FACE
EXIT LIGHT-SHADED AREA DENOTES DIRECTION OF SIGN FACE
ADDITIONAL 'E' DESIGNATES EXISTING EXIT LIGHT
VISUAL SIGNALING UNIT - WALL MOUNTED
FLASHING "FIRE" LIGHT ONLY (NO AUDIO DEVICE)
FIRE ALARM ANNUNCIATOR PANEL, FLUSH MOUNTED
MANUAL PULL STATION
COMBINATION AUDIBLE/VISUAL SIGNALING
UNIT- CHIME/FLASHING "FIRE" LIGHT
FIRE ALARM CONTROL PANEL
SECURITY CAMERA
CEILING OUTLET BOX AND SMOKE DETECTOR
2 X 4 FLUORESCENT WITH BATTERY INVERTER BACK-UP
SMOKE ALARM & ANNUNCIATOR FOR DUCT-MOUNTED SMOKE
DETECTORS
LIFE SAFETY LEGEND
1. FIRE EXTINGUISHERS TO BE LOCATED A MAXIMUM OF 75 FEET FROM ANY
LOCATION.
2. EXISTING LIFE SAFETY DEVICES ARE TO REMAIN. SCOPE OF WORK DOES
NOT AFFECT/ DIMINISH EGRESS PATHS OR CAPACITY.
NOTES
S -
E -
TRAVEL
PATH
80'
CORRIDOR
WIDTH XX"
MERGE
P1 0 P2
FEC
SD
BA
FEC
SA
FAAP
FACP
F
F
F
E
EXIT LIGHTEXIT
EXIT LIGHT IN PUBLIC AREASEXIT
EMERGENCY LIGHT
EGRESS DOORWAY WIDTH IN INCHES PROVIDED
W
M A
EGRESS CAPACITY CALCULATED MAX. OCCUPANT LOAD (0.2)
ACTUAL OCCUPANT LOAD CALCULATED
TO PASS THROUGH THIS OPENING
XX"
XX
XX
C FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED.J:\City of Kissimmee\Jobs\Haven on Vine 2B\24-14068-02\Dwgs\Sheets\Architectural\A004 ANNEX BUILDING- LIFE SAFETY PLAN ; Plot Date: Friday, February 21, 2025 ,8:31:18 AM; Plotted By: eduardoc
JO
B N
A M
E
S H
E E T N
A M
E
ISSUE - REVISION LOG
AR102538 - CA30900
H A V E N
O N
V
IN
E -2
B W
E S T V
IN
E S
T R
E E T K
IS
S
IM
M E E F L
S E A L
M A R K
D A T E
D E S C R
IP
T
IO
N
1230 Oakley Seaver Drive, Suite 100
Clermont, Florida 34711
888.850.FFAE (3323)
www.forefrontae.com
JOB # :
SHEET NUMBER :
24-14068
DATE : 02/28/2025
/0
/0
SCALE:
ANNEX BUILDING - LIFE SAFETY PLAN
1/4"=1'-0"
C
IT
Y O
F K
IS
S
IM
M E E J
U R
IS
D
IC
T
IO
N S
U B M
IT
T A
PLAN NORTH
EXISTING CEILING HEIGHT
EXISTING CEILING HEIGHT
EXISTING CEILING HEIGHT
2D
2D
2A
2A
2B
2F
2F
2L
EXISTING
CEILING
HEIGHT
2C
2C 2C
DEMOLITION REFERENCE KEYNOTES
2A - REMOVE EXISTING WALL
2B - REMOVE EXISTING DOOR
2C -
REMOVE EXISTING THRU-WALL MECHANICAL UNIT BELOW
WINDOW
2D - REMOVE EXISTING TOILET
2F -
REMOVE EXISTING BASEBOARD, FLOORING AND CEILING
- PATCH AND REPAIR AS NEEDED
2L -
REMOVE EXISTING CABINET, COUNTERTOP AND SINK -
PATCH AND REPAIR AS NEEDED
DEMOLITION PLAN LEGEND
TO REMAIN - EXISTING WALL
REMOVE WALL
TO REMAIN - EXISTING WINDOW
REMOVE - HINGED DOOR
1. THE PURPOSE OF THESE DOCUMENTS IS TO SHOW THE GENERAL ARRANGEMENT
AND EXTENT OF DEMOLITION SCOPE OF WORK.
2. REMOVE PORTIONS OF EXISTING CONSTRUCTION AS SHOWN AND AS NECESSARY.
PROTECT AREA FROM DAMAGE WHICH MAY OCCUR FROM DEMOLITION, DUST, WATER,
ETC. PROVIDE AND MAINTAIN TEMPORARY SECURITY FENCE AND CHAIN-LINK
CONSTRUCTION FENCE AS REQUIRED DURING THE PERIOD OF CONSTRUCTION.
3. DAMAGE TO EXISTING STRUCTURES, FINISH, AND EQUIPMENT SHALL BE REPAIRED
OR REPLACED TO THE SATISFACTION OF THE ARCHITECT, AT THE EXPENSE OF THE
GENERAL CONTRACTOR.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING ALL LEFT OVER
MATERIALS, DEBRIS, TOOLS AND EQUIPMENT INVOLVED IN HIS OPERATIONS AT THE
CONCLUSION OF THE WORK.
5. CONTRACTOR SHALL REPAIR OR REPLACE ANY FENCE, SIDEWALK, PAVING,
LANDSCAPING, OR ANY OTHER BUILDING MATERIAL OR SYSTEM DAMAGED AS A
RESULT OF LABOR, MATERIAL AND EQUIPMENT DELIVERY AND HANDLING.
6. THE ARCHITECT AND THE ARCHITECT'S CONSULTANTS SHALL HAVE NO
RESPONSIBILITY FOR THE DISCOVERY, PRESENCE, HANDLING, REMOVAL OR DISPOSAL
OF, OR EXPOSURE OF PERSONS TO ASBESTOS, HAZARDOUS OR TOXIC SUBSTANCES IN
ANY FORM AT THE PROJECT SITE. PROFESSIONAL SERVICES RELATED OR IN ANY WAY
CONNECTED WITH THE INVESTIGATION, DETECTION, ABATEMENT, REPLACEMENT,
USE, SPECIFICATION, OR REMOVAL OF PRODUCTS, MATERIALS OR PROCESSES
CONTAINING ASBESTOS, HAZARDOUS OR TOXIC MATERIALS ARE BEYOND THE SCOPE
OF THIS CONTRACT.
7. LOCATE, IDENTIFY, DISCONNECT AND SEAL OR CAP OFF PLUMBING, ELECTRICAL
AND FIRE ALARM/LOW VOLTAGE UTILITIES SERVING BUILDINGS TO BE DEMOLISHED.
COORDINATE ANY SHUT-OFF WITH OWNER. REMOVE EXISITNG WIRING BACK TO
SOURCE. IF REQUIRED, PROVIDE TEMPORARY UTILITY THAT BYPASS BUILDINGS TO BE
DEMOLISHED AND THAT MAINTAIN CONTINUITY OF SERVICE TO OTHER BUILDINGS.
DO NOT START DEMOLITION UNTIL UTILITY DISCONNECTING AND SEALING HAVE
BEEN COMPLETED AND VERIFIED IN WRITING. DISCONNECT, DEMOLISH AND REMOVE
ELECTRICAL, FIRE ALARM, PLUMBING AND HVAC SYSTEMS, EQUIPMENT AND
COMPONENTS TO BE REMOVED. REMOVE PORTIONS OF PIPING INDICATED TO BE
REMOVED AND CAP OR PLUG REMAINING PIPE WITH SAME OR COMPATIBLE PIPING
MATERIAL. BACKFILL HOLES FROM REMOVED ITEMS IN GROUND TO [E] ADJACENT
SUBGRADE ELEVATIONS
8. PROTECT EXISTING EXISTING LINES: CONTRACTOR SHALL HAVE LINES SURVEYED,
MARKED, AND FLAGGED SO EXCAVATOR AND OTHERS CAN CLEARLY SEE THE LINE
ROUTE. ASSURE HEAVY EQUIPMENT DOES NOT CROSS THE LINES.
9. PROPERLY DISPOSE OF ALL BATTERIES, FREON, LIGHT BALLASTS, ETC.
10. PROTECT ALL IRRIGATION SYSTEMS, PIPES, AND VALVES. SYSTEM TO REMAIN
OPERATIONAL DURING DEMOLITION.
FLOOR PLAN NOTES
1. CONTRACTOR SHALL COMPLY WITH THE STATE OF FLORIDA STATE BUILDING CODE CURRENT EDITION, THE FLORIDA BUILDING CODE 2023 (WITH ALL APPLICABLE
REVISIONS), FLORIDA FIRE PREVENTION CODE 2023, ALL STATE AND LOCAL ZONING CODES AND THE CITY OF KISSIMMEE. PERMITS SHALL BE POSTED IN A VISIBLE PLACE AT
ALL TIMES.
2. ALL PERMITS, UTILITY AND METER CONNECTION FEES SHALL BE OBTAINED AND PAID FOR BY THE CONTRACTOR.
3. ALL WORK, MATERIALS AND EQUIPMENT UTILIZED IN THIS PROJECT SHALL BE NEW AND INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS
AND SPECIFICATIONS.
4. ALL WORK FOR THIS PROJECT SHALL CONFORM TO STANDARDS PUBLISHED BY RECOGNIZED PROFESSIONAL AND INDUSTRY ORGANIZATIONS.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR VISITING THE SITE PRIOR TO BIDDING AND FAMILIARIZING HIMSELF WITH ALL EXISTING CONDITIONS AFFECTING THE WORK, INCLUDING BUT NOT LIMITED TO PRIVATE AND PUBLIC UTILITIES, ON AND OFF SITE, ACCESS ROADS AND OTHER SUPPORT FACILITIES.
6. CONTRACTOR TO REMOVE, RELOCATE OR RE-ROUTE, AS NECESSARY, ELECTRICAL, TELEPHONE, WATER, SEWER, GAS (IF APPLICABLE) OR ANY OTHER UTILITY LINES
ENCOUNTERED AND SHALL COORDINATE THIS WORK WITH ALL LOCAL UTILITY COMPANIES.
7. CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY UNEXPECTED OR UNKNOWN FIELD CONDITIONS, ERRORS, OMISSIONS, OR DISCREPANCIES IN THE
DRAWINGS, PROJECT MANUAL, OR CONTRACT DOCUMENT.
8. CONTRACTOR SHALL PREPARE AND MAINTAIN ALL CONSTRUCTION AREAS, AS WELL AS SURROUNDING AREAS FREE OF DEBRIS OR HAZARDOUS EQUIPMENT AT ALL TIMES.
9. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR AND/OR THE REPLACEMENT OF ANY ITEMS DAMAGED DURING CONSTRUCTION OR CLEAN-UP. CONSTRUCTION
PERSONNEL SHALL BE CONFINED TO THE LIMITS OF THE CONSTRUCTION AREA. ALL OSHA REGULATIONS FOR CONSTRUCTION AREAS SHALL BE STRICTLY FOLLOWED.
10. DRAWINGS ARE NOT TO BE SCALED. WRITTEN DIMENSIONS SHALL BE FOLLOWED.
11. ALL DIMENSIONS ARE BASED ON NOMINAL SIZES OF MEMBERS AND ARE GIVEN TO THE OUTER FACE OF SUCH MEMBERS, NOT TO FACE OF FINISH MATERIALS UNLESS
OTHERWISE NOTED ON DRAWINGS. WHERE A DIMENSION IS LABELED "CLEAR" IT IS TAKEN FROM THE FACE OF FINISH MATERIALS TO FACE OF FINISH MATERIALS.
12. CONTRACTOR TO SUBMIT SHOP DRAWINGS FOR APPROVAL BEFORE COMMENCING FABRICATION AND/OR INSTALLATION OF ALL APPLICABLE ITEMS FOR CONSTRUCTION. ALL
SHOP DRAWINGS DIMENSIONS SHALL BE FIELD VERIFIED, REVIEWED AND APPROVED BY CONTRACTOR BEFORE SUBMITTAL. SHOP DRAWINGS WHICH ARE INCOMPLETE OR
LACKING SUFFICIENT INFORMATION WILL BE RETURNED WITHOUT REVIEW. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS
13. PRESSURE TREATED WOOD SHALL BE USED WHERE WOOD IS IN CONTACT WITH CONCRETE OR MASONRY OR IN CONTACT WITH THE ELEMENTS (EXTERIOR).
14. CONTRACTOR TO FURNISH AND INSTALL ALL METAL AND WOOD BLOCKING REQUIRED FOR WALL MOUNTED OR BRACED FIXTURES, MILLWORK, SHELVES, BATHROOM FIXTURES AND ACCESSORIES OR BY OTHER ITEMS DESCRIBED IN INTERIOR DESIGN AND ARCHITECTURAL DRAWINGS.
15. IN ADDITION TO WALL TYPES SHOWN ON PLANS THE CONTRACTOR SHALL REFER TO THE ROOM FINISH SCHEDULE, INTERIOR ELEVATIONS AND DETAILS FOR
ADDITIONAL INFORMATION REGARDING FINISHES.
16. CONTRACTOR SHALL COORDINATE WITH MECHANICAL AND ELECTRICAL CONTRACTORS THE LOCATION OF ALL ACCESS PANELS SO AS TO ALLOW FOR PROPER
EQUIPMENT ACCESSIBILITY, MAINTENANCE, AND/OR OPERATION OF THE BUILDING SYSTEMS PRIOR TO THE START OF WORK. THE OMISSIONS OF ANY OR ALL
ACCESS PANELS DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY FROM PROVIDING AND INSTALLING SUCH PANELS OR DOORS. ACCESS PANELS IN
RATED ELEMENTS SHALL HAVE THE SAME FIRE RATING.
17. CONTRACTOR SHALL PAINT ALL VISIBLE SURFACES OF FACTORY PRIMED OR FACTORY PAINT FINISHED EQUIPMENT, A.C. GRILLS OR REGISTERS, COVERS, ETC.
UNLESS SPECIFICALLY NOTED OTHERWISE VERIFY AND COORDINATE COLORS WITH INTERIOR DESIGN AND ARCHITECT.
18. ALL INTERIOR AND EXTERIOR JOINTS BETWEEN DIFFERENT MATERIALS OR FINISHES SHALL RECEIVE A BEAD OF CAULKING OR FORM A REVEAL TO MATCH COLOR
OF ADJACENT SURFACE. COORDINATE COLORS WITH ARCHITECT.
19. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING ALL DEBRIS AND CONSTRUCTION MATERIAL FROM THE SITE. CONTRACTOR SHALL ALSO BE RESPONSIBLE
FOR PROPERLY CLEANING ALL AREAS PRIOR TO FINAL ACCEPTANCE BY THE OWNER INCLUDING BUT NOT LIMITED TO WINDOWS, FLOORS, CARPETS, WALLS, DOORS, EQUIPMENT, ETC.
20. UPON COMPLETION OF THIS PROJECT, THE CONTRACTOR SHALL GIVE TO THE OWNER A COMPLETE SET OF AS-BUILT CIVIL, LANDSCAPE, ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL ALONG WITH THE WRITTEN GUARANTIES, OPERATION AND MAINTENANCE MANUALS OF ALL EQUIPMENT AND FINISHES
INSTALLED. THE CONTRACTOR SHALL MAINTAIN A CURRENT SET OF AS-BUILT DRAWINGS AND SPECIFICATIONS. INFORMATION SHALL BE RECORDED BY
CONTRACTOR AS CONSTRUCTION PROGRESSES AND REVIEWED FOR COMPLETENESS AT EACH REQUISITION REQUEST. REFER TO PROJECT MANUAL.
21. CONTRACTOR SHALL PROVIDE PROPER SAFEGUARDS IN COMPLIANCE WITH THE LIFE SAFETY PLANS DURING ALL PHASES OF CONSTRUCTION.
22. CONTRACTOR TO PROVIDE A SAFETY PLAN PRIOR TO START OF CONSTRUCTION TO CLEARLY DELINEATE AREAS FOR CONSTRUCTION, SAFETY BARRIERS, EXITS, CONSTRUCTION TRAFFIC DURING THE VARIOUS PHASES AND WHEN CONDITIONS CHANGE.
C FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED.J:\City of Kissimmee\Jobs\Haven on Vine 2B\24-14068-02\Dwgs\Sheets\Architectural\A100 ANNEX BUILDING - EXISTING AND DEMOLITION ; Plot Date: Monday, February 17, 2025 ,5:17:27 PM ; Plotted By: minelg
JO
B N
A M
E
S H
E E T N
A M
E
ISSUE - REVISION LOG
AR102538 - CA30900
H A V E N
O N
V
IN
E -2
B W
E S T V
IN
E S
T R
E E T K
IS
S
IM
M E E F L
S E A L
M A R K
D A T E
D E S C R
IP
T
IO
N
1230 Oakley Seaver Drive, Suite 100
Clermont, Florida 34711
888.850.FFAE (3323)
www.forefrontae.com
JOB # :
SHEET NUMBER :
24-14068
DATE : 02/28/2025
/2
/2
PLAN NORTH
SCALE:
ANNEX BUILDING - EXISTING AND DEMOLITION FLOOR PLAN
3/8"=1'-0"
C
IT
Y O
F K
IS
S
IM
M E E J
U R
IS
D
IC
T
IO
N S
U B M
IT
T
EXISTING CEILING HEIGHT
2'-0" 4'-0" 2'-0"
12'-0"
4'-0"
25'-10"14'-3"
EXISTING CEILING HEIGHT
EXISTING CEILING
HEIGHT
EXISTING CEILING HEIGHT
EXISTING CEILING HEIGHT
1'-11" 2'-0"
A102
A101
A
4'-0"4"6'-10"
EXISTING
CEILING HEIGHT
TYP.
3'-0"
INFILL WITH
CONSTRUCTION TO
MATCH EXISTING
EXTERIOR WALL
4. ALL EXTERIOR WALLS, LESS OPENINGS, ARE TO BE
CONSIDERED SHEAR WALLS. ALL ROUGH OPENING
WINDOW SIZES MUST BE VERIFIED BY WINDOW
CONTRACTOR PRIOR TO CONSTRUCTION. SEE
STRUCTURAL SPECIFICATIONS FOR MATERIAL TYPE.
5. WHERE THE OPENING OF AN OPERABLE WINDOW IS
LOCATED MORE THAN 72" ABOVE FINISHED GRADE OR
SURFACE BELOW, THE LOWEST PART OF THE CLEAR
OPENING OF THE WINDOW SHALL BE A MINIMUM OF 24"
ABOVE THE FINISHED FLOOR OF THE ROOM IN WHICH IT
IS LOCATED.
3-COAT (7/8" MIN.
THICKNESS)
STUCCO SYSTEM
CMU COLUMN PER
STRUCTURAL
GROUT JOINT,
STRIKE FLUSH AT
COLUMN EXTERIOR
FINISHES LEGEND
BF1 BASEBOARD - REAL WOODS - RWBA - 03 (9/16" X 5-1/4") - (OR SIMILAR)
WF1 PAINTED GYPSUM - SHERWIN WILLIAMS. SW7636 (OR SIMILAR)
CF1 PAINTED EXISTING GYPSUM BOARD (WHITE)
FF1 24"x24" DALTILE -SUPERIOR SLIP RESISTANCE FLOOR TILE. MODEL: SCRIPER -MENTOR SQUARE-COLOR:
AR62-MATTE - (OR SIMILAR)
FF2 PAINTED CONCRETE
ALL NEW FINISH MATERIAL TO HAVE CLASS B FLAME SPREAD RATING MINIMUM
MAIN OFFICE FINISHES SCHEDULE
ROOM NAME
AREA MAT.
FLOORS
N S E W
WALL MATERIAL
HGT. MATL
CEILINGS
NOTES
OPEN OFFICE SPACE
FIRE RISER
HALLWAY
RESTROOM 1
733 SF
20 SF
52 SF
45 SF
FF1
FF2
FF1
FF1
BF1/WF1 BF1/WF1 ±7'-11" (EXISTING) CF1BF1/WF1 BF1/WF1
FF1
CF1
CF1
CF1
CF1RESTROOM 2
45 SF
ELECTRICAL ROOM 34 SF FF2 CF1
BF1/WF1 BF1/WF1 BF1/WF1 BF1/WF1
WF1
WF1
BF1/WF1
BF1/WF1
WF1
WF1
WF1
WF1
WF1
WF1
±7'-11" (EXISTING)
±7'-11" (EXISTING)
±7'-11" (EXISTING)
±7'-11" (EXISTING)
±7'-11" (EXISTING)
BF1/WF1
BF1/WF1
BF1/WF1
BF1/WF1
BF1/WF1
BF1/WF1
C FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED.J:\City of Kissimmee\Jobs\Haven on Vine 2B\24-14068-02\Dwgs\Sheets\Architectural\A101 ANNEX BUILDING - PROPOSED FLOOR PLAN ; Plot Date: Tuesday, February 25, 2025 ,11:36:05 AM ; Plotted By: minelg
JO
B N
A M
E
S H
E E T N
A M
E
ISSUE - REVISION LOG
AR102538 - CA30900
H A V E N
O N
V
IN
E -2
B W
E S T V
IN
E S
T R
E E T K
IS
S
IM
M E E F L
S E A L
M A R K
D A T E
D E S C R
IP
T
IO
N
1230 Oakley Seaver Drive, Suite 100
Clermont, Florida 34711
888.850.FFAE (3323)
www.forefrontae.com
JOB # :
SHEET NUMBER :
24-14068
DATE : 02/28/2025
/2
/2
SCALE:
ANNEX BUILDING - PROPOSED FLOOR PLAN
3/8"=1'-0"
PLAN NORTH
C
IT
Y O
F K
IS
S
IM
M E E J
U R
IS
D
IC
T
IO
N S
U B M
IT
T A L
SCALE:
PLAN VIEW OF TYP. CMU COLUMN
1"=1'-0"
N
EW
S
10D22E 10A 22B 10E
A102
10B10E22B 10G
EAST ELEVATIONNORTH ELEVATION WEST ELEVATION
22B10A22E
22E10F
SOUTH ELEVATION
10D
REFERENCE KEYNOTES
10A -
36" GRAB BAR ADA COMPLIANT - HORIZONTAL POSITION -
BOBBRICK B-6806X36 OR SIMILAR
10B -
RECESSED TOILET TISSUE DISPENSER - BOBBRICK B-667 -
OR SIMILAR
10D -
WELDED-FRAME MIRROR - BOBBRICK B-290 2436 - OR
SIMILAR
10E -
42" GRAB BAR ADA COMPLIANT - HORIZONTAL POSITION -
BOBBRICK B-6806X42 OR SIMILAR
10F -
SURFACE-MOUNTED PAPER TOWEL DISPENSER - BOBBRICK
B-262 ClassicSeries - OR SIMILIAR
10G -
SURFACE-MOUNTED SEAT COVER DISPENSER - BOBBRICK
B-4221 ConturaSeries - OR SIMILAR
22B - TOILET PER PLUMBING
22E - WALL MOUNTED SINK - PER PLUMNBING
C FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED.J:\City of Kissimmee\Jobs\Haven on Vine 2B\24-14068-02\Dwgs\Sheets\Architectural\A102 ANNEX BUILDING RESTROOMS - ENLARGED AND ELEVATIONS ; Plot Date: Monday, February 17, 2025 ,5:11:25 PM ; Plotted By: minelg
JO
B N
A M
E
S H
E E T N
A M
E
ISSUE - REVISION LOG
AR102538 - CA30900
H A V E N
O N
V
IN
E -2
B W
E S T V
IN
E S
T R
E E T K
IS
S
IM
M E E F L
S E A L
M A R K
D A T E
D E S C R
IP
T
IO
N
1230 Oakley Seaver Drive, Suite 100
Clermont, Florida 34711
888.850.FFAE (3323)
www.forefrontae.com
JOB # :
SHEET NUMBER :
24-14068
DATE : 02/28/2025
/2
/2
PLAN NORTH
SCALE:
ENLARGED PROPOSED RESTROOM FLOOR PLAN - TYPICAL
1/2"=1'-0"
SCALE:
PROPOSED RESTROOM ELEVATIONS - TYPICAL
1/2"=1'-0"
C
IT
Y O
F K
IS
S
IM
M
E E
J U
R
IS
D
IC
T
IO
N S
U B
M
IT
T
0'-0"
F. F.
EXISTING DOOR
TO BE REMOVED
0'-0"
F. F.
THRU-WALL MECHANCIAL UNIT TO
BE REMOVED (TYP.)
0'-0"
F. F.
0'-0"
F. F.
SCALE:
ANNEX BUILDING - EXISTING & DEMO LEFT ELEVATION
1/4"=1'-0" SCALE:
ANNEX BUILDING - EXISTING & DEMO RIGHT ELEVATION
1/4"=1'-0"
SCALE:
ANNEX BUILDING - EXISTING & DEMO FRONT ELEVATION
1/4"=1'-0"
SCALE:
ANNEX BUILDING - EXISTING & DEMO REAR ELEVATION
1/4"=1'-0"
C FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED.J:\City of Kissimmee\Jobs\Haven on Vine 2B\24-14068-02\Dwgs\Sheets\Architectural\A200 ELEVATIONS - EXISTING AND DEMOLITION ; Plot Date: Tuesday, February 18, 2025 ,11:03:35 AM ; Plotted By: eduardoc
JO
B N
A M
E
S H
E E T N
A M
E
ISSUE - REVISION LOG
AR102538 - CA30900
H A V E N
O N
V
IN
E -2
B W
E S T V
IN
E S
T R
E E T K
IS
S
IM
M E E F L
S E A L
M A R K
D A T E
D E S C R
IP
T
IO
N
1230 Oakley Seaver Drive, Suite 100
Clermont, Florida 34711
888.850.FFAE (3323)
www.forefrontae.com
JOB # :
SHEET NUMBER :
24-14068
DATE : 02/28/2025
/2
/2
C
IT
Y
O F
K
IS
S
IM
M E
E J
U R
IS
D
IC
T
IO
N
S U
B M
IT
T
0'-0"
F. F.
9'-0"
BEAR. HGT.
MATCH NEW ROOF PITCH TO
EXISTING (FIELD VERIFY)
REPLACE ALL EXISTING ASPHALT
SHINGLES WITH NEW METAL
ROOF
ACCENT COLOR APPLIED ON
BOTTOM HALF, BELOW THE TRIM,
OVERALL. UPPER PORTION WILL
CONTINUE THE MAIN BODY
COLOR.
WESTERN LOCK STANDING SEAM METAL ROOFING
- COLOR: NATURAL ZINC METALLIC (TYP.)
MAIN BODY OF BUILDING, UNLESS
OTHERWISE NOTED IS 3-COAT (7/8"
MIN THICKNESS) STUCCO SYSTEM2"x4" ADHERED
FOAM TRIM -
PAINTED SW7076
(TYP.)
ACCENT COLOR
A201
TYP.
0'-0"
F. F.
9'-0"
BEAR. HGT.
ACCENT COLOR APPLIED ON
BOTTOM HALF, BELOW THE TRIM,
OVERALL. UPPER PORTION WILL
CONTINUE THE MAIN BODY
COLOR.
MAIN BODY OF BUILDING, UNLESS
OTHERWISE NOTED IS 3-COAT (7/8"
MIN THICKNESS) STUCCO SYSTEM
REPLACE ALL EXISTING ASPHALT
SHINGLES WITH NEW METAL
ROOF
2"x4" ADHERED
FOAM TRIM -
PAINTED SW7076
(TYP.)
NEW THRU-WALL MECHANICAL
UNIT PER MECHANICAL (TYP.)
0'-0"
F. F.
9'-0"
BEAR. HGT.
REPLACE ALL EXISTING ASPHALT
SHINGLES WITH NEW METAL
ROOF
MATCH NEW ROOF PITCH TO
EXISTING (FIELD VERIFY)
WESTERN LOCK STANDING
SEAM METAL ROOFING - COLOR:
NATURAL ZINC METALLIC (TYP.)
2"x4" ADHERED
FOAM TRIM -
PAINTED SW7076
(TYP.)
ACCENT COLOR
ACCENT COLOR APPLIED ON
BOTTOM HALF, BELOW THE TRIM,
OVERALL. UPPER PORTION WILL
CONTINUE THE MAIN BODY
COLOR.
MAIN BODY OF BUILDING, UNLESS
OTHERWISE NOTED IS 3-COAT (7/8"
MIN THICKNESS) STUCCO SYSTEM
0'-0"
F. F.
9'-0"
BEAR. HGT.
REPLACE ALL EXISTING ASPHALT
SHINGLES WITH NEW METAL
ROOF
MATCH NEW ROOF PITCH TO
EXISTING (FIELD VERIFY)
WESTERN LOCK STANDING
SEAM METAL ROOFING - COLOR:
NATURAL ZINC METALLIC (TYP.)
2"x4" ADHERED
FOAM TRIM -
PAINTED SW7076
(TYP.)
ACCENT COLOR
ACCENT COLOR APPLIED ON
BOTTOM HALF, BELOW THE TRIM,
OVERALL. UPPER PORTION WILL
CONTINUE THE MAIN BODY
COLOR.
MAIN BODY OF BUILDING, UNLESS
OTHERWISE NOTED IS 3-COAT (7/8"
MIN THICKNESS) STUCCO SYSTEM
A201
TYP.
BUILDING PAINT COLOR NOTES:
- OVERALL MAIN BODY COLOR: SHERWIN WILLIAMS - SW7656/RHINESTONE
- ACCENT COLOR : SHERWIN WILLIAMS - SW6522/SPORTY BLUE (FOR ACCENT COLOR LOCATIONS REFER TO ELEVATIONS)
- ALL NEW AND EXISTING TRIM BORDERS AND CORBELS COLOR: SHERWIN WILLIAMS - SW7076/CYBERSPACE
- ALL EXISTING AND NEW RAILINGS OR METAL RODS TO BE PAINTED BLACK
GROUT JOINT,
STRIKE FLUSH AT
COLUMN EXTERIOR
CMU COLUMN PER
STRUCTURAL
3-COAT (7/8" MIN.
THICKNESS) STUCCO
SYSTEM
2"x2" ADHERED FOAM
TRIM - TRIM
PAINTED SW7076
(TYP.)
SEALANT, ALL JOINTS
TYP.
WEEP SCREED
1/2" MIN.
COMPRESSIBLE
EXPANSION JOINT
CONCRETE
SIDEWALK WHERE
OCCURS
CONCRETE FOOTING
PER STRUCTURAL
STUCCO FINISH
COAT - TRIM PAINT
SW7076 (TYP.)
BETWEEN THE
TRIMS: 3-COAT (7/8"
MIN. THICKNESS)
STUCCO SYSTEM -
PAINT SW7656 (TYP.)
PAINT CMU TO
MATCH ACCENT
FINISH (SW7656)
3-COAT (7/8" MIN.
THICKNESS) STUCCO
SYSTEM - PAINT
ACCENT COLOR:
SW6522/SPORTY
BLUE
A201
A
1/2" MIN. GYPSUM
SHEATHING
CONTINUOUS SOFFIT VENT
LVL BEAM PER STRUCTURAL
- NOTE: AS OCCURS SEE
ELEVATIONS
WESTERN LOCK
STANDING SEAM
METAL ROOFING -
COLOR: NATURAL
ZINC METALLIC
ROOFING UNDERLAYMENT
ROOFING SHEATHING PER
STRUCTURAL
PRE-MANUFACTURED
ROOF TRUSSES
R-38 BATT
INSULATION (OVER
HABITED SPACES)
METAL DRIP EDGE
3-COAT (7/8" MIN. THICKNESS)
STUCCO SYSTEM - PAINT
SW6522 (TYP.)
2x4 SPACER FRAMING
C FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED.J:\City of Kissimmee\Jobs\Haven on Vine 2B\24-14068-02\Dwgs\Sheets\Architectural\A201 ELEVATIONS - PROPOSED ; Plot Date: Tuesday, February 18, 2025 ,11:03:40 AM ; Plotted By: eduardoc
JO
B N
A M
E
S H
E E T N
A M
E
ISSUE - REVISION LOG
AR102538 - CA30900
H A V E N
O N
V
IN
E -2
B W
E S T V
IN
E S
T R
E E T K
IS
S
IM
M E E F L
S E A L
M A R K
D A T E
D E S C R
IP
T
IO
N
1230 Oakley Seaver Drive, Suite 100
Clermont, Florida 34711
888.850.FFAE (3323)
www.forefrontae.com
JOB # :
SHEET NUMBER :
24-14068
DATE : 02/28/2025
/2
/2
SCALE:
ANNEX BUILDING - PROPOSED LEFT ELEVATION
1/4"=1'-0" SCALE:
ANNEX BUILDING - PROPOSED RIGHT ELEVATION
1/4"=1'-0"
SCALE:
ANNEX BUILDING - PROPOSED FRONT ELEVATION
1/4"=1'-0"
SCALE:
ANNEX BUILDING - PROPOSED REAR ELEVATION
1/4"=1'-0"
C
IT
Y O
F K
IS
S
IM
M
E E
J U
R
IS
D
IC
T
IO
N S
U B
M
IT
T A
L
SCALE:
COLUMN DETAIL (TYP.)
3/8"=1'-0"
SCALE:
COLUMN SECTION CUT (TYP.)
3/8"=1'-0"
SCALE:
EAVE DETAIL (TYP.)
1/2"=1'-0"
H I
P
H I P
H I P
H I
P
R I D G E
H I
P
H I P
H I P
H I
P
R I D G E
R I
D G
E
H I P
4/12 :
FIELD
VERIFY
BUILDER NOTE: FIELD
VERIFY ROOF PITCH AND
OVERHANG - NEW ROOF
PITCH AND OVERHANG
TO MATCH EXISTING.
/1
F
IE
L D
V E R
IF
Y
4/12 :
FIELD
VERIFY
VALLEY
VA
LL
EY
WESTERN LOCK STANDING SEAM METAL
ROOFING - COLOR: NATURAL ZINC
METALLIC (TYP.)
NEW CONTINUOUS RIDGE VENT TO
MATCH METAL ROOFING
C FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED.J:\City of Kissimmee\Jobs\Haven on Vine 2B\24-14068-02\Dwgs\Sheets\Architectural\A300 ROOF PLAN - EXISTNG AND PROPOSED ; Plot Date: Tuesday, February 25, 2025 ,1:57:01 PM; Plotted By: minelg
JO
B N
A M
E
S H
E E T N
A M
E
ISSUE - REVISION LOG
AR102538 - CA30900
H A V E N
O N
V
IN
E -2
B W
E S T V
IN
E S
T R
E E T K
IS
S
IM
M E E F L
S E A L
M A R K
D A T E
D E S C R
IP
T
IO
N
1230 Oakley Seaver Drive, Suite 100
Clermont, Florida 34711
888.850.FFAE (3323)
www.forefrontae.com
JOB # :
SHEET NUMBER :
24-14068
DATE : 02/28/2025
/2
/2
C
IT
Y
O F
K
IS
S
IM
M E
E J
U R
IS
D
IC
T
IO
N
S U
B M
IT
T
A L
PLAN NORTH
SCALE:
ROOF PLAN - EXISTING
1/4"=1'-0"
SCALE:
ROOF PLAN - PROPOSED
3/8"=1'-0"
EXISTING CEILING HEIGHT
EXISTING CEILING HEIGHT
EXISTING
CEILING
HEIGHT
LIGHT
FIXTURE
PER
ELECTRICAL
LIGHT
FIXTURE
PER
ELECTRICAL
NEW LIGHT
FIXTURE PER ELECTRICAL
(TYP.)
EXISTING CEILING HEIGHT
1. DIMENSIONS NOTED IN EACH AREA DESIGNATE CEILING
HEIGHT ABOVE FINISH FLOOR.
2. SEE PLUMBING AND ELECTRICAL DRAWINGS FOR LOCATIONS
OF LIGHT FIXTURES IN EXPOSED CEILING AREA.
3. CONTRACTOR TO COORDINATE ALL DISCIPLINES TO ENSURE
CLEARANCES FOR AL DUCTWORK, EQUIPMENT, FIXTURES,
PIPES, CONDUITS, SUSPENSION AND ACOUSTIC SYSTEMS
NECESSARY TO MAINTAIN CEILING ELEVATION NOTED
SYMBOL DESCRIPTION
CEILING TYPES
EXISTING GYPSUM BOARD
CEILING PATCH AND REPAIR
AS REQUIRED.
LIGHTING TYPES
SYMBOL DESCRIPTION
CEILING LIGHT FIXTURE
NEW 2X2 ACOUSTICAL
CEILING GRID
WALL MOUNT LIGHT FIXTURE
C FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED.J:\City of Kissimmee\Jobs\Haven on Vine 2B\24-14068-02\Dwgs\Sheets\Architectural\A400 ANNEX BUILDING - REFLECTED CEILING PLAN ; Plot Date: Friday, February 21, 2025 ,8:31:21 AM ; Plotted By: eduardoc
JO
B N
A M
E
S H
E E T N
A M
E
ISSUE - REVISION LOG
AR102538 - CA30900
H A V E N
O N
V
IN
E -2
B W
E S T V
IN
E S
T R
E E T K
IS
S
IM
M E E F L
S E A L
M A R K
D A T E
D E S C R
IP
T
IO
N
1230…