Attachment B - Approved for Const Project Drawings - 12.11.23.pdf
PDF 16 MB Posted
- Attached to
- Rathskellar Kitchen Renovation - 247-181082
- Solicitation number
- 55606
- Issued by
- Fairfax County, Fairfax City, Virginia
About this file
Attachment B - Approved for Const Project Drawings - 12.11.23.pdf is a set of project drawings for a construction project. The drawings were approved on December 11, 2023 and appear to be for a state or local government project. The drawings provide detailed plans and specifications for the construction work, including site layouts, building elevations, and engineering diagrams. No other project details, such as the scope of work, timeline, or contract terms, are provided in this document.
The document does not contain information about pricing, set-asides, incumbents, funding sources, or other salient contract details. This appears to be a standalone set of construction drawings without the accompanying solicitation or contract documents.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T h e C a n n o n C o rp o ra ti o n
A ll ri g h ts r e s e rv e d N o p a rt o f th is d o c u m e n t m a y b e r e p ro d u c e d o r u ti liz e d i n a n y f o rm w it h o u t p ri o r w ri tt e n a u th o ri z a ti o n b y T h e C a n n o n C o rp o ra ti o n
BOSTON NEW YORK BALTIMORE WASHINGTON DC BUFFALO TORONTO COLUMBUS PITTSBURGH
DALLAS CHICAGO ST. LOUIS IRVINE DENVER HOUSTON LOS ANGELES MUMBAI
CD #: 006193.03
4469 Aquia Creek Ln Fairfax, VA 22030
RATHSKELLAR DINING SPACE RENOVATION PROJECT
GEORGE MASON UNIVERSITY
GMU #: 181082
/2 /2
:5
:2
A M
WORKING DRAWINGS R3
11/22/2023
1560 Wilson Blvd. Suite 200
Arlington, VA 22209 P: 703.907.2300 F: 703.907.2050
DRAWING INDEX
SHEET NUMBER SHEET NAME
00 GENERAL
G0000 COVER SHEET
G0201 CODE COMPLIANCE
G0300 LIFE SAFETY PLAN
G0301 UL PENETRATION DETAIL
10 DEMOLITION
D0201 DEMOLITION PLAN
D0701 DEMOLITION REFLECTED CEILING PLAN
D0801 LEVEL 01 DEMOLITION PLAN
PD0100 UNDERSLAB - PLUMBING DEMOLITION PLAN
PD0101 LEVEL 01 - PLUMBING DEMOLITION PLAN
PD0201 LEVEL 01 - DOMESTIC WATER FLOOR PLAN
40 ARCHITECTURAL
A0001 SYMBOLS & ABBREVIATIONS
A0002 MOUNTING HEIGHTS
A0101 FLOOR PLAN
A0601 INTERIOR ELEVATIONS
A0602 INTERIOR ELEVATIONS
A0701 REFLECTED CEILING PLAN
A0800 INTERIOR DETAILS
A0801 CEILING DETAILS
A1001 INTERIOR PARTITION TYPES
A1010 INTERIOR PARTITION DETAILS
A1011 TYPICAL PARTITION HEAD OF WALL DETAILS
A1012 TYPICAL WALL FRAMING DETAILS
A1021 FINISHES & DOOR DETAILS
A1100 EQUIPMENT PLAN
A1231 FINISH PLAN
A1232 CORRIDOR FINISH PLAN
50 PLUMBING
P0001 LEGENDS, SYMBOLS & ABBREVIATIONS
P0100 UNDER SLAB - PLUMBING NEW WORK PLAN
P0101 LEVEL 01 - PLUMBING NEW WORK PLAN - SANITARY & VENT
P0201 LEVEL 01 - PLUMBING NEW WORK PLAN - DOMESTIC WATER
P0401 PLUMBING RISER DIAGRAMS
60 FIRE PROTECTION
FX0001 LEGENDS, SYMBOLS & ABBREVIATIONS
FX0101 LEVEL 01 - FIRE PROTECTION FLOOR PLAN
FX0102 LEVEL 01 - FIRE PROTECTION FLOOR PLAN - CALCULATIONS
FX0501 DETAILS
70 MECHANICAL
M0001 SYMBOLS, ABBREVIATIONS, AND GENERAL NOTES
M0101 LEVEL 01 - HVAC DUCTWORK DEMO AND NEW PLAN
M0501 SCHEDULES, DETAILS, AND CONTROL DIAGRAMS
80 ELECTRICAL
E0001 NOTES, LEGENDS, SYMBOLS AND ABBREVIATIONS
E0101 LEVEL 01 LIGHTING PLAN, LIGHTING FIXTURE SCHEDULE
AND LPD CALCULATION
E0101A LEVEL 01 LIGHTING PLANS WITH CALCULATIONS
E0101B LIGHTING CONTROL SCHEMATIC DIAGRAM
E0201 LEVEL 01 POWER AND SYSTEMS PLAN
E0521 DEMOLITION AND NEW WORK RISER DIAGRAMS
E0621 POWER SCHEDULES
E0721 POWER DETAILS
AC0101 LEVEL 01 ACCESS CONTROL PLAN
FA0101 LEVEL 01 FIRE ALARM PLAN
T0101 LEVEL 01 TELECOM/AV PLAN
VICINITY MAP
N
POINTS OF CONTACT:
CANNONDESIGN
PROJECT MANAGER:
CARRIE PARKER
703.907.2300 cparker@cannondesign.com
MASON FACILITIES
PROJECT MANAGER:
CHRISTY HOGAN
703.993.2559 chogan6@gmu.edu
MASON INFORMATION
TECHNOLOGY
SERVICES/NETWORKING
PROJECT MANAGER:
HABTEWOLD MESFEN
703.993.9523 hmesfen@gmu.edu
MASON FACILITIES
CFR:
Jesus Sanchez 571 241 5080 jsanch54@gmu.edu
OUBO Review Stamp
Date = 12/11/2023
APPROVED AS NOTED
FOR CONSTRUCTION
Student Union Building-1 bldg # 0033
APPLICABLE CODES,
STANDARDS, AND ORDINANCES:
1. GEORGE MASON UNIVERSITY
OFFICE OF UNIVERSITY BUILDING OFFICIAL
4400 UNIVERSITY DRIVE, MS 1E4
FAIRFAX, VA 22030
AUTHORITIES HAVING JURISDICTION:
MAXIMUM TRAVEL DISTANCES:
COMMON PATH OF TRAVEL (CP)
ALLOWABLE MAXIMUM = 75'
ACTUAL MAXIMUM - REFER TO PLANS
EXIT ACCESS TRAVEL DISTANCE
ALLOWABLE MAXIMUM = 250'
ACTUAL MAXIMUM - REFER TO PLANS
DEAD ENDS
"A" USE, FULLY SPRINKLED
ALLOWABLE MAXIMUM = 20'
CONSTRUCTION CLASSIFICATION:
CONSTRUCTION TYPE: VCC 2015 - TYPE IIA (EXISTING)
VCC 2015 - TYPE IIA (NEW CONSTRUCTION)
GENERAL INFORMATION:
EXISTING BUILDING IS FULLY SPRINKLERED
AUTOMATIC SPRINKLER SYSTEM: YES NFPA 13 (EXISTING)
FIRE ALARM SYSTEM: YES NFPA 72 (EXISTING)
STANDPIPE SYSTEM: YES NFPA 14 (EXISTING)
OCCUPANCY:
EXISTING BUILDING CLASSIFICATION: B OFFICES/CLASSROOMS,
A-3 MEETING ROOMS
A-2 RESTAURANTS, DINING
PROJECT CLASSIFICATION: A-2 RESTAURANTS, DINING
ADDITIONAL USE AREAS: KITCHEN, OFFICE
LEAD MATERIALS DISCLOSURE STATEMENT:
IT IS THE CONTRACTOR’S RESPONSIBILITY TO COMPLY WITH ALL VIRGINIA
OCCUPATIONAL SAFETY AND HEALTH (VOSH) REGULATIONS AS THEY PERTAIN TO
EMPLOYEE EXPOSURES TO LEAD.
ALL LEAD AND LEAD-COATED BUILDING COMPONENTS SHALL BE RECYCLED TO THE
EXTENT POSSIBLE.
ASBESTOS DISCLOSURE STATEMENT:
STATEMENT #2:
AN ASBESTOS INSPECTION WAS PERFORMED AND ACM WAS FOUND GENERALLY IN
THE AREAS INDICATED. HOWEVER, THE WORK IN THIS PROJECT IS NOT INTENDED TO
DISTURB THE EXISTING ACM. THE ASBESTOS INSPECTION REPORT IS INCLUDED AS AN
APPENDIX TO THE PROJECT SPECIFICATIONS.
ADDITIONAL NOTES:
• PER THE ACM REPORT, ACM WAS DISCOVERED IN AN AREA ADJACENT TO THE
WORK AREA, BUT IS NOT INTENDED TO BE DISTURBED AS PART OF THIS WORK.
• ASBESTOS CONTAINING MATERIALS SHALL NOT BE INCLUDED IN ANY NEW
CONSTRUCTION.
• ALL SUSPECT MATERIALS MUST BE PHYSICALLY SAMPLED AND ANALYZED.
• SHOULD ADDITIONAL ACM BE DISCOVERED, THE ACM IS TO BE REMOVED BY A
VIRGINIA LICENSED ASBESTOS ABATEMENT CONTRACTOR.
FIRE PROTECTION:
THE EXISTING BUILDING IS PROTECTED BY A COMPLETE
BUILDING SPRINKLER PROTECTION PER NFPA 13.
• OFFICES AND CIRCULATION AREAS - LIGHT HAZARD
• LABS AND STORE ROOMS - ORDINARY HAZARD
GROUP 2 MINIMUM
• UTILITY ROOMS - ORDINARY HAZARD GROUP 1
ADDRESSABLE VOICE EVACUATION FIRE ALARM SYSTEM
PER NFPA 72
• MASS NOTIFICATION CAPABLE.
AREA OF WORK:
GROSS AREA: 3559 SF (LIMITED TO RENOVATION AREA OF BUILDING)
EGRESS:
REFER TO SHEET G0300 FOR OCCUPANT LOAD AND
EGRESS CALCULATIONS FOR THE PROPOSED PROJECT
AND EXISTING LEVEL 01.
PER VCC 2018 SECTION 1006.2 AND 1006.3, THE MINIMUM
NUMBER OF EXITS REQUIRED BASED ON THE TOTAL
OCCUPANCY LOAD OF THE PROPOSED PROJECT:2.
HIGH PERFORMANCE BUILDING ACT:
PER GMU HECO MANUAL 7.2.6.2, IN ACCORD WITH THE HIGH
PERFORMANCE BUILDING ACT, THE BUILDING IS EXEMPT FROM
COMPLIANCE BECAUSE THE COST OF THE RENOVATIONS DOES NOT
EXCEED 50% OF THE VALUE OF THE BUILDING.
VIRGINIA ENERGY CONSERVATION CODE:
IN ACCORD WITH THE VIRGINIA ENERGY CONSERVATION CODE (VECC),
THE BUILDING SHALL COMPLY WITH VECC SECTIONS C402 THROUGH
C405 AND C408.
ASHRAE 90.1-2013 SECTIONS 5, 6, 7, 8, 9, & 10. SECTION 5 COMPLIANCE
WILL BE VIA SECTION 5.5 – PRESCRIPTIVE BUILDING ENVELOPE OPTION.
SECTION 6 COMPLIANCE WILL BE VIA SECTIONS 6.4 – MANDATORY
PROVISIONS AND 6.5 – PRESCRIPTIVE PATH.
2018 Virginia Uniform Statewide Building Code (VUSBC) includes the following
2018 Virginia Existing Building Code 2018 Virginia Construction Code 2018 Virginia Statewide Fire Prevention Code 2018 Virginia Mechanical Code 2018 Virginia Maintenance Code 2018 Virginia Energy Conservation Code 2018 Virginia Plumbing Code 2018 Virginia Fuel Gas Code 2018 Virginia Existing Building Code 2017 National Electrical Code (NEC)
2010 ADA Standards for Accessible Design 2013 GMU Design Manual 2023 GMU HECO Manual
ALTERATION, LEVEL 2
SCOPE OF WORK INCLUDE THE ADDITION OR ELIMINATION OF WALLS
AND CEILINGS. INCLUDES RECONFIGURATION OF PLUMBING SYSTEMS.
CLASSIFICATION OF WORK PER
2018 VEBC 103.9:
OCCUPANT LOAD
REFER TO RESPECTIVE FLOOR CODE COMPLIANCE PLAN FOR DETAILED OCCUPANT
LOAD CALCULATIONS, SHEET G0300.
1. THE FLOOR PLAN BACKGROUND FOR NEW AND EXISTING CONSTRUCTION IS
SHOWN IN GRAY HALF-TONE.
2. DESIGNATIONS FOR FIRE RATED PARTITIONS, SMOKE PARTITIONS AND
OTHER CODE COMPLIANCE RELATED INFORMATION ARE SHOWN FULL TONE.
REFER TO CONTRACT DRAWINGS TO DETERMINE WHICH COMPONENTS ARE
NEW AND WHICH ARE EXISTING.
3. THE FIRE AND SMOKE DESIGNATIONS FOR EXISTING CONSTRUCTION ARE
SHOWN FOR REFERENCE ONLY AND ARE BASED ON INFORMATION PROVIDED
BY OWNER. THIS INFORMATION HAS NOT BEEN INDEPENDENTLY VERIFIED BY
CANNON DESIGN.
4. REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF EXIT LIGHTS,
EMERGENCY LIGHTS, AND FIRE ALARM
5. SYSTEM.
6. REFER TO FIRE PROTECTION DRAWINGS FOR LOCATIONS OF SPRINKLERS
AND FIRE PUMP.
7. REFER TO PLUMBING DRAWINGS FOR PLUMBING FIXTURE COUNTS.
8. REFER TO STRUCTURAL DRAWINGS FOR STRUCTURAL LOADS.
9. ALL FURNITURE INDICATED ON THE PLANS ARE PLACEHOLDERS TO SCALE
AND INTENT. FINAL FURNITURE SELECTIONS WILL BE COORDINATED WITH
THE REQUIREMENTS OF THE USER IN ASSOCIATION WITH VCE.
GENERAL NOTES
Checked by:Project No.:
Drawing Title:
© 2022 The Cannon Corporation.
T h e C a n n o n C o rp o ra ti o n
A ll ri g h ts r e s e rv e d N o p a rt o f th is d o c u m e n t m a y b e r e p ro d u c e d o r u ti liz e d i n a n y f o rm w it h o u t p ri o r w ri tt e n a u th o ri z a ti o n b y T h e C a n n o n C o rp o ra ti o n
GMU 181082; CD 006193.03
Rev. Description Date www.cannondesign.com
A
1 2 3 4 5 6
B
C
D
E
RATHSKELLAR DINING
SPACE RENOVATION
PROJECT
4469 Aquia Creek Ln Fairfax, VA
WORKING DRAWINGS 04 AUG 2023
/2 /2
:5
:2
A M
G0201
CODE COMPLIANCE
SW
VCC 2018 - TABLE 601 - TYPE IIA
ITEM FIRE RATING
BEARING WALLS:
FIRE RESISTANCE RATINGS
EXTERIOR
INTERIOR
PRIMARY STRUCTURAL FRAME 1 HR
1 HR
1 HR
1 HR
NON-BEARING WALLS
AND PARTITIONS:
EXTERIOR
INTERIOR
VCC table 602
0 HR
FLOOR CONSTRUCTION &
SECONDARY MEMBERS
1 HR
ROOF CONSTRUCTION &
SECONDARY MEMBERS
1 HR
NOTE: ADDITIONAL FIRE PROTECTION RATINGS ARE
REQUIRED FOR SPECIFIC INSTANCES. REFER TO FIRE
PROTECTION PLANS FOR EXTENT OF ADDITIONAL RATINGS
REQUIRED.
1560 Wilson Blvd. Suite 200
P: 703.907.2300
F: 703.907.2050
Arlington, VA 22209
DESIGN DATA EXCHANGE (DDx) INFORMATION
DDx CONSTRUCTION TYPE
YEAR OF OCCUPANCY
COUNTRY
STATE
COUNTY
CITY
ZIP CODE
MARKET SECTOR
BUILDING TYPE
CBECS PRIMARY BUILDING TYPE
CBECS ANCILLARY TYPE 2
CBECS ANCILLARY TYPE 1
CBECS ANCILLARY TYPE 3
1. THE BASELINE BUILDING PERFORMANCE AND THE PROPOSED BUILDING PERFORMANCE NUMBERS ARE PRESENTED FOR COMPARISON PURPOSES, TO INFORM WHICH ENERGY CONSERVATION STRATEGIES
HAVE THE MOST IMPACT.
2. NEITHER THE BASELINE BUILDING PERFORMANCE, NOR THE PROPOSED BUILDING PERFORMANCE ARE PREDICTIONS OF ACTUAL ENERGY CONSUMPTION OR ENERGY COSTS AND ARE NOT SUITABLE FOR
OPERATIONAL BUDGETING OR OTHER DEFINITIVE FINANCIAL PLANNING PURPOSES.
3. THE ACTUAL ENERGY CONSUMPTION AND ENERGY EXPENDITURES OF THE BUILDING WILL DIFFER FROM THESE CALCULATIONS DUE TO VARIATIONS IN OCCUPANCY, BUILDING OPERATIONS, BUILDING
MAINTENANCE, WEATHER, ENERGY USES NOT COVERED BY THIS ANALYTICAL PROCEDURE, AND
CHANGES IN ENERGY RATES BETWEEN DESIGN OF THE BUILDING AND OCCUPANCY.
APPROVED COMPLIANCE TOOLS
ComCheck is only a valid compliance tool if the project will comply with the PRESCRIPTIVE REQUIREMENTS for the all of the following; building envelope, building mechanical systems, service water heating systems, and electrical power and lighting systems in their entirety.
ADOPTED ENERGY CODE CLIMATE ZONE
WARM / HUMID
MOIST / DRY / MARINE
STATE ENERGY CODE STANDARD
ENERGY CODE ADOPTION DATE
ENERGY CODE EFFECTIVE DATE
DESIGN ENERGY CODE STANDARD
CURRENT CLIMATE ZONE
ENRGY CODE ANTICIPATED REVISION DATE
ENERGY CODE COMPLIANCE PATHWAY
YEAR OF CONTRACT DOCUMENTS ISSUANCE
STORIES
STATE ENFORCEMENT
GROSS BUILDING AREA (GSF)
CBECS PRIMARY BUILDING TYPE AREA
CBECS ANCILLARY TYPE 1 AREA
CBECS ANCILLARY TYPE 2 AREA
CBECS ANCILLARY TYPE 3 AREA
ENERGY CODE INFORMATION
DESIGN DATA EXCHANGE (DDx) AREA TABLE
ENERGY MODELING
% REDUCTION FROM bEUI bEUITarget EUI CURRENT DESIGN kBTU/SF/YR
% REDUCTION FROM bLPD bLPDTarget LPD CURRENT DESIGN
W/FT2
LIGHTING POWER DENSITY (LPD)
PREDICTED ENERGY USE INTENSITY(pEUI)
CALIFORNIA TITLE 24 CLIMATE ZONE
Bm EUI
Bm LPD
22030
84,462 SF
N/A N/A N/A N/A
N/A N/A N/A
0.99 0.75
25%
0.65
39%
1.06
VIRGINIA
ALL
USA
FAIRFAX
EXISTING BUILDING
MOIST
VIRGINIA ENERGY CONSERVATION CODE
NO
NA
2018 VIRGINIA ENERGY CONSERVATION CODE
EDUCATION-HIGHER
STUDENT CENTER
MERCANTILE
OFFICE - MEDIUM (10,000-100,000 SF)
FOOD SERVICE-GENERAL
VIRGINIA
ASHRAE 90.1 MANDATORY PROVOSIONS + PRESCRIPTIVE
REQUIREMENTS
1 WORKING DRAWINGS R1 13 SEP 23
2 WORKING DRAWINGS R2 20 OCT 23
OUBO Review Stamp
Date = 12/11/2023
APPROVED FOR
CONSTRUCTION
S SS S
S SS
S S
DINING
AREA
THE
RATHSKELLER
EXISTING
CORRIDOR
EXISTING
KITCHEN
1201B
FE
E X
IT
B
50' - 0"
EXIT C
E X
IT
C
9' - 7 5/8"
EXIT C
/8
E X
IT
C
E X
IT
D
/8
E X
IT
A
27' - 11"
EXIT A
12' - 6"
EXIT A
EXISTING
VESTIBULE
1000A
RENOVATED
KITCHEN
1201A
WALK-IN
1210A.1
ASSEMBLY - UNCOCENTRATED SEATING
EXISTING KITCHEN
7' - 0"
EXIT F
34' - 0"
EXIT A
4' - 5"
EXIT B
EXIT B
(EXISTING)
56"
EC: 280
EO:
EXIT C
(EXISTING)
67"
EC: 335
EO:
EXIT A
(EXISTING)
36"
EC:180
EO:
9' - 1"
EXIT D
E X
IT
D
29' - 8"
EXIT D
E X
IT
D
115' - 3 3/4"
EXIT E
66' - 0"
EXIT E
EXIT E
(EXISTING)
36"
EC:180
EO:
EXIT D
(EXISTING)
36"
EC: 180
EO:
DINING
AREA
AREA NOT IN
SCOPE
AREA NOT IN
SCOPE
AREA NOT IN
SCOPE
REFER TO ELECTRICAL
FOR WORK IN THIS AREA
EXISTING 2-HR RATED
PARTITION TO REMAIN
EXISTING 2-HR RATED
PARTITION TO REMAIN
EXISTING 1-HR RATED
PARTITION TO REMAIN
EXISTING 1-HR RATED
PARTITION TO REMAIN
DRY
STORAGE
1208A CATERING
1201C
4' - 0"
EXIT F
E X
IT
F
E X
IT
F
88' - 1 3/4"
EXIT F
E X
IT
A
LEGEND
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
FIRE HOSE VALVE CABINET
OR STANDPIPE CONNECTION
FIRE ALARM ANNUNCIATOR PANEL
FIRE DEPARTMENT CONNECTION
1 HOUR FIRE
1 HOUR FIRE / SMOKE
2 HOUR FIRE
2 HOUR FIRE / SMOKE
ABLE TO RESIST PASSAGE OF SMOKE
EXIT ACCESS CORRIDOR
EXIT
ANN
FE
FEC
FHV
AREA OF RESCUE
EXIT STAIR
EGRESS PATH/ TRAVEL DISTANCE
XX'
XX'
XX'
TOTAL EXIT ACCESS TRAVEL DISTANCE
TRAVEL DISTANCE
IN-ROOM OR IN-SUITE
TRAVEL DISTANCE
EXIT ACCESS DOOR
TO EXIT
SMOKE BARRIER
EGRESS CAPACITY - PROPOSED AND
EXISTING BUILDING
EXIT NO. WIDTH WIDTH/
OCC.
EGRESS
CAPACITY
(EC)
EGRESS
OCCUPANTS
(EO)
COMPLIES REMAINING
EGRESS
CAPACITY
EXIT A/F
EXIT B
EXIT C
EXIT D
36"
56"
67"
EXIT E
0.2"
0.2"
0.2"
0.2"
0.2"
36"
36"
84 *
0 *
85 *
3 *
0 *
YES * 96 *
280 *
250 *
177 *
180 *
*NOTE: AS THIS IS AN EXISTING BUILDING, ADDITIONAL USES ARE PRESENT WHICH ALSO
UTILIZE THESE EXITS. AS THERE IS NO CHANGE IN USE/OCCUPANCY OF THE
RENOVATION AREA, IT IS ASSUMED THE EXISTING EGRESS CAPACITY AND OCCUPANT
LOADS HAVE REMAINS THE SAME. FOR THE PURPOSES OF THIS CALCUALTION, WE HAVE
ASSUMED THE KITCHEN OCCUPANCY EGRESSES OUT EXIT D, WHILE THE REMAINING
OCCUPANT LOAD FOR THIS SPACE IS SPLIT BETWEEN EXITS A AND C AS THESE ARE THE
PRIMARY DOORS SERVING THS RENOVATED SPACE.
YES *
YES *
YES *
YES *
MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS FOR THIS PROJECT SCOPE (PER VCC
2015 SECTION 1006.2)
FLOOR
LEVEL:
CALCULATED
OCCUPANT LOAD
NUMBER OF
EXITS REQUIRED
NUMBER OF
EXITS PROVIDED
EXIT PROVIDED AT
GRADE (YES/NO)
LEVEL 01 -
PROJECT
SCOPE
(EAT CAFE)
172 2 (PER VCC 2015
SECTION 1006.2
AND 1006.3)
5 (EXISTING) YES
EGRESS
Checked by:Project No.:
Drawing Title:
© 2022 The Cannon Corporation.
T h e C a n n o n C o rp o ra ti o n
A ll ri g h ts r e s e rv e d N o p a rt o f th is d o c u m e n t m a y b e r e p ro d u c e d o r u ti liz e d i n a n y f o rm w it h o u t p ri o r w ri tt e n a u th o ri z a ti o n b y T h e C a n n o n C o rp o ra ti o n
GMU 181082; CD 006193.03
Rev. Description Date www.cannondesign.com
A
1 2 3 4 5 6
B
C
D
E
RATHSKELLAR DINING
SPACE RENOVATION
PROJECT
4469 Aquia Creek Ln Fairfax, VA
WORKING DRAWINGS 04 AUG 2023
/2 /2
:5
:3
A M
G0300
LIFE SAFETY PLAN
SW
0' 8' 16'
1/8" = 1'-0"A1
LEVEL 01 LIFE SAFETY PLAN
OCCUPANT LOAD SUMMARY
NAME COMMENTS AREA
SF/
OCCUPANT
OCCUPANT
LOAD
ASSEMBLY -
UNCONCENTRATED
SEATING
Cafeteria 2499 SF 15 167
BUSINESS Business 142 SF 100 2
KITCHEN Cafeteria Kitchen 470 SF 200 3
Grand total 3112 SF 172
OCCUPANCY LEGEND
EGRESS PATH DISTANCE
EGRESS PATH COMMON PATH TRAVEL DISTANCE
EXIT A YES 34' - 0"
EXIT A 27' - 11"
EXIT A 12' - 6"
EXIT A 15' - 0 3/8"
EXIT A 10' - 1"
99' - 6 1/2"
EXIT B YES 32' - 6"
EXIT B YES 4' - 5"
36' - 11"
EXIT C YES 15' - 7 3/8"
EXIT C 50' - 0"
EXIT C 9' - 7 5/8"
EXIT C 12' - 3"
87' - 6 1/8"
EXIT D YES 50' - 0"
EXIT D YES 9' - 1"
EXIT D 15' - 4"
EXIT D 29' - 8"
EXIT D 18' - 2"
122' - 3"
EXIT E 115' - 3 3/4"
EXIT E 66' - 0"
181' - 3 3/4"
EXIT F YES 7' - 0"
EXIT F 4' - 0"
EXIT F 3' - 7"
EXIT F 24' - 0"
EXIT F 88' - 1 3/4"
126' - 8 3/4"
1560 Wilson Blvd. Suite 200
P: 703.907.2300
F: 703.907.2050
Arlington, VA 22209
1 WORKING DRAWINGS R1 13 SEP 23
OUBO Review Stamp
Date = 12/11/2023
10B
10A
5 3
Section A-A
10A
10B
A
A
Type of Metallic Penetrant
Steel or Iron Pipe, Conduit
Max Dim of T Rating, HrThrought Penetrants, 1/2
3/4
12 (305)
6 (152)
2 (51)
1(25)
Copper Pipe or Tube
4 (102)Steel or Iron Pipe, Conduit or EMT 1/4
In.(mm)
Steel or Iron Pipe, Conduit or EMT
Steel or Iron Pipe, Conduit or EMT
ANSI/UL1479 (ASTM E814)
F Rating - 2 Hr
CAN/ULC S115
F Rating - 2 Hr
FH Rating - 2 Hr
1. Floor or Wall Assembly - Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete. Wall may also be constructed of any UL Classified Concrete Blocks* . Max area of opening is 1024 sq in.
(0.66 m2) with a max height of 32 in. (813 mm) when installed in a wall or a max width of 32 in. (813 mm) when installed in a floor.
2. Metallic Penetrants - One or more metallic pipes, conduits or tubes to be installed within the opening. Annulus between penetrants is min 0 in. (point contact) to max 24 in. (609 mm). Annulus between penetrants and periphery of opening is 0 in.
(point contact) to max 24 in. (609 mm). Penetrants rigidly supported on both sides of floor or wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used:
A. Steel Pipe - Nom 12 in. (305 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe.
B. Iron Pipe - Nom 12 in. (305 mm) diam (or smaller) cast or ductile iron pipe.
C. Conduit - Nom 6 in. (152 mm) diam (or smaller) rigid steel conduit, nom 4 in. (102 mm) diam (or smaller) electrical metallic tubing (EMT), or nom 4 in. (102 mm) diam (or smaller) steel Flexible Metal Conduit#.
D. Copper Pipe or Tube - Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe or Type M (or heavier) copper tube.
3. Pipe Insulation - One or more max 4 in. (102 mm) metallic pipes or tubes may be insulated. Annulus between penetrants is min 0 in. (point contact) to max 24 in. (609 mm). Annulus between penetrants and periphery of opening is 0 in. (point contact) to max 24 in. (609 mm). The annular space between metallic pipes, conduit and tubes and insulated pipes and tubes shall be a min 1/2 in. (13 mm) to max 24 in. (609 mm). Penetrants rigidly supported on both sides of floor or wall assembly. The following types of pipe insulation may be used:
A. Pipe and Equipment Covering Materials* - Nom 1 in. (25 mm) thick hollow cylindrical heavy density (min 3.5 pcf or 56 kg/m3) glass fiber units jacketed on the outside with an all service jacket. Longitudinal joints sealed with metal fasteners or factory-applied self-sealing lap tape. Transverse joints secured with metal fasteners or with butt tape supplied with the product.When Item 3A is used, T Rating is 3/4 Hr.
B. Pipe Covering Materials* - Nom 2 in. (51 mm) thick unfaced mineral fiber pipe insulation having a nom density of 3.5 pcf (56 kg/m3) (or heavier) and sized to the outside diam of the pipe or tube. Pipe insulation secured with min 8 AWG steel wire spaced max 12 in. (305 mm) OC. When Item 3B is used, T Rating is 2 Hr .
C. Sheathing Material* - Use in conjunction with Item 3B. Foil-scrim-kraft or all service jacket material shall be wrapped around the outer circumference of the pipe insulation (Item 3B) with the kraft side exposed. Longitudinal and transverse joints sealed with metal fasteners or butt tape.
D. Tube Insulation-Plastics## - Nom 3/4 in. (19 mm) thick acrylonitrile butadiene/polyvinyl chloride (AB/PVC) flexible foam furnished in the form of tubing.When Item 3D is used, T Rating is 1/2 Hr.
E. Pipe Covering Materials* - Cellular Glass Insulation - Nom 2 to 3 in. (51 to 76 mm) thick cellular glass units sized to the outside diam of the pipe or tube and supplied in nom 24 in. (610 mm) long half sections or nom 18 in.(457 mm) long segments. Pipe insulation installed on pipe in accordance with the manufacturer's instructions. When Item 3E is used, T Rating is 2 Hr.
F. Metal Jacket - Used in conjunction with Item 3E. Min 12 in. (305 mm) long jacket formed from min 0.010 in. (0.25 mm) thick aluminum sheet cut to wrap tightly around the pipe insulation with a min 2 in. (51 mm) lap and secured using bands and seals of a similar material or min No. 18 AWG steel tie wire. Bands or steel tie wire to be located within 2 in. (51 mm) of each end of the jacket and spaced max 10 in. (254 mm) OC. Jacket installed with edge abutting surface of fill material (Item 9A) on top surface of floor or both surfaces of wall. Metal jacket to be used in addition to any other jacketing material which may be required on the pipe covering.
G. Pipe and Equipment Covering Materials* - Nom 2 to 3 in. (51 to 76 mm) thick hollow cylindrical calcium silicate (min 14 pcf or 224 kg/m3) units sized to the outside diam of the pipe or tube. Pipe insulation secured with stainless steel bands or min 8 AWG stainless steel wire spaced max 12 in. (305 mm) OC. When Item 3G is used, T Rating is 2 Hr.
4. Nonmetallic Penetrants - One or more nonmetallic pipes, conduits or tubes to be installed within the opening. Annulus between penetrants and periphery of opening is min 1 in. (25 mm) to max 24 in. (609 mm). Separation between metallic and nonmetallic penetrants is min 6 in. (152 mm). Penetrants rigidly supported on both sides of floor or wall assembly. The following types and sizes of nonmetallic pipes, conduits or tubing may be used:
A. Polyvinyl Chloride (PVC) Pipe - Nom 2 in. (51 mm) diam (or smaller) solid or cellular core Schedule 40 PVC pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems.
B. Chlorinated Polyvinyl Chloride (CPVC) Pipe - Nom 2 in. (51 mm) diam (or smaller) SDR13.5 CPVC pipe for use in closed (process or supply) piping systems.
C. Rigid Nonmetallic Conduit+ - Nom 2 in. (51 mm) diam (or smaller) Schedule 40 PVC conduit installed in accordance with the National Electrical Code (NFPA 70).
D. Electrical Nonmetallic Tubing (ENT)+ - Nom 2 in. (51 mm) diam (or smaller) corrugated wall ENT formed of polyvinyl chloride (PVC) installed in accordance with the National Electrical Code (NFPA 70).
E. Optical Fiber Raceway+ - Nom 2 in. (51 mm) diam (or smaller) optical fibner raceway (innerduct). Optical fiber raceway installed in accordance with Article 770 of the National Electrical Code (NFPA 70).
When Item 4 is used, the T Rating of the firestop system is 2 hr.
5. Cables - Nom 4 in. (102 mm) diam (or smaller) tight bundle of cables. Annulus between cable bundle and periphery of opening is min 0 in. (point contact) to max 24 in. (609 mm). Separation between cable bundle and metallic or nonmetallic penetrants shall be min 6 in. (152 mm). Cable bundle rigidly supported on both sides of floor or wall assembly. The following types and sizes of cables may be used:
A. Max 1/C - 1000 kcmil cable with polyvinyl chloride (PVC) or cross-linked polyethylene (XLPE) insulation and jacket.
B. Max 7/C - No. 12 AWG cable with PVC-nylon insulation and PVC jacket.
C. Max 400 pair - No. 24 AWG copper conductor telephone cable with PVC insulation and jacket.
D. Max RG/U coaxial cables with fluorinated ethylene jacket and insulation.
E. Multiple fiber optic cables with PVC insulation.
F. Through Penetrating Products* - Max 4/C with ground No. 2/O AWG Metal-Clad Cable+.
When cables are used, T Rating is 1/2 hr.
6. Cable Tray - Max 30 in. (762 mm) wide by max 6 in. (152 mm) deep open ladder cable tray with channel-shaped side rails formed from min 0.060 in. (1.5 mm) thick (No. 16 MSG) galv steel or min 0.060 in. (1.5 mm) thick aluminum with rungs spaced max 9 in. (229 mm) OC. A max of two cable trays may be installed within the opening with a min vertical separation of 4 in.
(102 mm) and a min horizontal separation of 1/4 in. (6 mm) between trays. Max vertical or horizontal separation is 24 in. (609 mm). Annulus between the cable tray and the periphery of the opening is min 0 in. (point contact) to max 24 in. (609 mm).
Separation between cable tray and metallic or nonmetallic penetrants is min 6 in. (152 mm). Cable trays to be rigidly supported on both sides of the floor or wall assembly. Aggregate cross-sectional area of cables in cable tray not to exceed 40 percent of the cross-sectional area of the cable tray based on a max 3 in. (76 mm) cable loading depth within tray. Any combination of the cable types specified in Item 5 may be used. When cable tray is used, T Rating is 1/2 hr.
7. Busway+ - Nom 19 in. (483 mm) wide (or smaller) by 6 in. (152 mm) deep "I" shaped aluminum enclosure containing factory-mounted copper bars rated for 600 V, 5000 A or max 26 in. (660 mm) wide by max 6 in. (152 mm) deep "I" shaped aluminum enclosure containing factory-mounted aluminum bars rated for 600 V, 4000 A. A max of two busways may be installed within the opening with a min separation of 1 in. (25 mm) to max 24 in. (609 mm). The annular space between the busway and the periphery of the opening shall be a min 0 in. (point contact) to a max 24 in. (609 mm). Busways spaced min 6
in. (152 mm) from all other penetrants. Busway to be rigidly supported on both sides of floor or wall assembly. The busway shall bear the UL Listing Mark and shall be installed in accordance with all provisions of the National Electrical Code, NFPA
70. When busway is used, the T Rating is 1/4 hr.
8. Air Conditioning (AC) Line Set - One or more AC line sets installed within opening. Each AC line set consists of two pipes or tubes (Item 8A), tubing insulation (Item 8B) and a thermostat cable (Item 8C). The space between the AC line sets shall be min 2 in. (51 mm). The space between the AC line sets and the periphery of the opening shall be min 0 in. (point contact) to max 24 in. (609 mm). The AC line sets shall be spaced min 6 in. from uninsulated metallic penetrants and shall be rigidly supported on both sides of the floor or wall assembly.
8A. Through Penetrant - A max of two pipes or tubes to be installed in each AC line set. Of the two pipes or tubes, only one may have a nom diam greater than 1/2 in. (13 mm). The following types and sizes of through penetrants may be used:
A. Steel Pipe - Nom 1 in. (25 mm) diam (or smaller) Schedule 5 (or heavier) steel pipe.
B. Iron Pipe - Nom 1 in. (25 mm) diam (or smaller) cast or ductile iron pipe.
C. Copper Pipe - Nom 1 in. (25 mm) diam (or smaller) Regular (or heavier) copper pipe.
D. Copper Tube - Nom 1 in. (25 mm) diam (or smaller) Type L (or heavier) copper tube.
8B. Tube Insulation - Plastics# - Nom 3/4 in. (19 mm) thick acrylonitrile butadiene/polyvinyl chloride (AB/PVC) flexible foam furnished in the form of tubing. The tube insulation may be installed on one max 3/4 in. (19 mm) diam pipe or tube in each AC line set. The space between the insulated and uninsulated pipes or tubes within each AC line set shall be 0 in. (point contact).
8C. Cable - One 4 pair No. 18 AWG (or smaller) thermostat cable with polyvinyl chloride (PVC) insulation and jacket materials may be installed with each AC line set.
When Item 8 is used, the T Rating of the firestop system is 1/4 hr.
9. Steel Duct - (Not Shown) Nom 12 in. (305 mm) diameter (or smaller) No. 30 GA (or heavier) steel duct installed within opening when opening contains no cables or cable tray. A max of two steel ducts may be installed within the through-opening.
Ducts to be spaced min 4 in. (102 mm) apart and min 8 in. (203 mm) from insulated penetrants and nonmetallic penetrants.
Annulus between the steel duct and the periphery of the opening shall be min 0 in. (point contact) to max 24 in. (0 to 609 mm).
Steel ducts to be rigidly supported on both sides of floor or wall assembly. When steel duct is used, the T Rating is 0 hr.
10. Firestop System - The firestop system shall consist of the following items:
A. Packing Material - Min 4 in. (102 mm) thickness of min 4 pcf (64 kg/m3) mineral wool batt insulation tightly packed into opening. Packing material recessed from top surface of floor assembly or from both surfaces of wall or precast concrete units to accommodate the required thickness of fill material.
B. Fill, Void or Cavity Materials* - Sealant - Min 1/2 in. (13 mm) depth of fill material applied within the annulus, flush with top surface of floor assembly or with both surfaces of the wall assembly. Additional fill material forced into interstices of grouped cables and grouped cables within cable trays. At point contact location between through penetrant and concrete, a min 3/8 in. (9.6 mm) diam of fill material shall be applied at through penetrant/concrete interface on top surface of floor or both surfaces of the wall.
* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively.
#Bearing the UL Recognized Components Mark
+Bearing the UL Listing Mark
FT Rating - 0, 1/4, 1/2, 3/4 and 2 Hr (See Items 2 through 9)
FTH Rating - 0, 1/4, 1/2, 3/4 and 2 Hr (See Items 2 through 9)
T Rating - 0, 1/4, 1/2, 3/4 and 2 Hr (See Items 2 through 9)
Checked by:Project No.:
Drawing Title:
© 2022 The Cannon Corporation.
T h e C a n n o n C o rp o ra ti o n
A ll ri g h ts r e s e rv e d N o p a rt o f th is d o c u m e n t m a y b e r e p ro d u c e d o r u ti liz e d i n a n y f o rm w it h o u t p ri o r w ri tt e n a u th o ri z a ti o n b y T h e C a n n o n C o rp o ra ti o n
GMU 181082; CD 006193.03
Rev. Description Date www.cannondesign.com
A
1 2 3 4 5 6
B
C
D
E
RATHSKELLAR DINING
SPACE RENOVATION
PROJECT
4469 Aquia Creek Ln Fairfax, VA
WORKING DRAWINGS 04 AUG 2023
/2 /2
:5
:3
A M
G0301
UL PENETRATION DETAIL
SW
NTS
UL 1479 PENETRATION DETAIL
1560 Wilson Blvd. Suite 200
P: 703.907.2300
F: 703.907.2050
Arlington, VA 22209
1 WORKING DRAWINGS R1 13 SEP 23
OUBO Review Stamp
Date = 12/11/2023
DINING
AREA
THE
RATHSKELLER
EXISTING
CORRIDOR
EXISTING
KITCHEN
1201B
F6
F5
O1
O1
W1
F11
M3
F7
F8
K3
S1
M3
W1
O4
W1
F11
M2
F9
F10 F10
K1
F3
F4
F1
W1
F2
W2
F3
F15
EXISTING
VESTIBULE
1000A
DINING
AREA
Q U
A R
R Y
T
IL
E
E X
IS
T
.T
IL
E
T
IL
E
Q U
A R
R Y
T
IL
E
D1/D0201
TYP
TILE
EXIST. TILE
QUARRY TILE
TILE
AREA NOT
IN SCOPE
W3
W3
T3s
WT-3
TEMPORARY
CONSTRUCTION
BARRIER
TEMPORARY
CONSTRUCTION
BARRIER
TEMPORARY
CONSTRUCTION
BARRIER AND
LOCKABLE DOOR
T3s
T3s
T3s
F5
F11
O2 O2 O2
M1
/8
K2
TILE
CARPET
F5 F11 M1
S2
W4 W4
O5
F12
F13
O3 O2
OPENING JAMB
ALIGN WITH EXISTING 8'-6"
F14 F14
F5
Q U
A R
R Y
T
IL
E T
O R
E M
A
IN
Q U
A R
R Y
T
IL
E T
O D
E M
O L
IS
H
EXISTING OFFICE
K2
POWER
T1208
F16
F16
F16
F16
F16F16
W5
2'-6" 3'-4"
DEMOLITION LEGEND
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE REMOVED
FLOORING TRANSITION
AREA FOR TRENCHING
GENERAL NOTES
1. ALL ITEMS TO BE REMOVED SHALL BE REMOVED ENTIRELY, AND AFFECTED
SURFACES PREPARED TO RECEIVE NEW CONSTRUCTION. CONTRACTOR TO
PATCH AND REPAIR ANY DEMOLISHED AREAS NOT TO BE COVERED BY NEW
CONSTRUCTION.
2. PROTECT ALL EXISTING WORK TO REMAIN. REPAIR AS NECESSARY ANY
DAMAGE TO REMAINING ITEMS WHICH OCCURS DURING DEMOLITION OR
CONSTRUCTION.
3. IN ALL WALLS AND CEILINGS SCHEDULED FOR REMOVAL, CONTRACTOR SHALL
DISCONNECT AT THE SOURCE ANY ANY ELECTRICAL CIRCUITS, AND CAP ALL
ABANDONED PLUMBING/UTILITIES BEHIND FINISHES, OR BELOW EXISTING
FLOOR. COMPLY WITH ALL APLICABLE CODES.
4. REFER TO MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR
EXISTING FIXTURES AND SERVICES TO BE REMOVED.
5. DEMOLITION IS NOT FULLY ILLUSTRATED ON DRAWINGS. PROVIDE DEMOLITION
AS REQUIRED TO ACCOMODATE NEW CONSTRUCTION.
6. ALL DIMENSIONS TO BE VERIFIED IN FIELD.
7. PATCH AND PREP ANY EXISTING FLOORS, WALLS, DOORS, DOOR FRAMES AND
CEILING TO RECEIVE NEW FINISHES.
8. DURING RENOVATION PROJECT, A FULL BUILDING FIRE WATCH SHALL BE
PROVIDED FOR ANY WORK THAT AFFECTS THE INTEGRITY OF THE FIRE ALARM
OR SPRINKLER SYSTEM. THIS INCLUDES ANY REMOVAL OF CEILING TILE
AROUND SPRINKLER HEADS THAT IS NOT REINSTALLED AT THE END OF THE
WORK DAY. FIRE WATCH SHALL BE PERFORMED BY A DEDICATED PERSON
AND SHALL FOLLOW THE PROCEDURES OUTLINED ON THE EHS WEBSITE. A
FIRE WATCH MAY NOT BE NEEDED IF A 2 HR CONSTRUCTION BARRIER IS
INSTALLED AROUND THE PERIMETER OF THE ENTIRE CONSTRUCTION AREA
AND PRIOR WRITTEN APPROVAL IS OBTAINED FROM GEORGE MASON AND
SFM.
9. CONTRACTOR TO PROVIDE QUALIFIED PERSONNEL TO PERFORM SPRINKLER
DRAIN DOWN AND RE-FLOW OF THE SPRINKLER SYSTEM. GMU WILL PROVIDE
ASSISTANCE DEMONSTRATING PROCEDURES UPON REQUEST.
10. REFER TO FOOD SERVICE EQUIPMENT DRAWINGS PREPARED BY OWNER'S
CONSULTANT FOR EQUIPMENT TO BE REMOVED, REUSED, OR REMAIN.
COORDINATE WITH OWBER FOR SALVAGE OR DISPOSAL INSTRUCTIONS.
11. REFER TO PLUMBING AND EQUIPMENT REQUIREMENTS TO COORDINATE FOR
NEW PLUMBING DRAIN LINES. SAW CUT EXISTING CONCRETE SLAB TO INSTALL
NEW PLUMBING DRAIN LINES. INFILL TRENCH PER DETAIL ON A0800.
12. REFER TO FIRE PROTECTION DRAWINGS FOR SPRINKLERS TO REMAIN,
REMOVE, OR RELOCATE.
13. EXISTING OFFICE SHALL BE OCCUPIED DURING CONSTRUCTION.
14. CONTRACTOR SHALL COMPLETELY AND CAREFULLY REMOVE ALL AV / IT
EQUIPMENT. OWNER SHALL HAVE FIRST RIGHT OF REFUSAL FOR DISPOSAL OF
EQUIPMENT.
2'-4 1/2"
/2
7"
ANCHOR TO (E)
CONC. SLAB
CONT. MEAL TOP
AND BOTTOM TRACK
REMOVE EXIST.
QUARRY TILE
COVE WALL BASE
REMOVE EXIST.
FRP WALL PANELS
M3
M3
M3
N
N
Checked by:Project No.:
Drawing Title:
© 2022 The Cannon Corporation.
T h e C a n n o n C o rp o ra ti o n
A ll ri g h ts r e s e rv e d N o p a rt o f th is d o c u m e n t m a y b e r e p ro d u c e d o r u ti liz e d i n a n y f o rm w it h o u t p ri o r w ri tt e n a u th o ri z a ti o n b y T h e C a n n o n C o rp o ra ti o n
GMU 181082; CD 006193.03
Rev. Description Date www.cannondesign.com
A
1 2 3 4 5 6
B
C
D
E
RATHSKELLAR DINING
SPACE RENOVATION
PROJECT
4469 Aquia Creek Ln Fairfax, VA
KEY PLAN
Project North VA State Grid North
WORKING DRAWINGS 04 AUG 2023
/2 /2
:5
:3
A M
D0201
DEMOLITION PLAN
SW
0' 4' 8'
1/4" = 1'-0"A1
LEVEL 01 DEMOLITION PLAN
DEMOLITION KEYED NOTES:
NUMBER DESCRIPTION
F1 REMOVE EXISTING WALL-MOUNTED LAMINATE COUNTERTOP & BRACKETS.
F2 REMOVE EXISTING 34"H CASEWORK, INCLUDING COUNTERTOPS, 32"H
PARTIAL-HEIGHT WALL, TILE AND LIGHT BOX ON EXTERIOR FACE, AND FRP
PANELS ON INTERIOR FACE.
F3 EXISTING QUARRY TILE FLOOR AND BASE TO REMAIN
F4 EXISTING TILE FLOORING TO REMAIN
F5 REMOVE EXISTING TILE FLOORING AND TILE/COVE WALL BASE & PREPARE
EXIST. CONC SLAB TO RECEIVE NEW FLOOR FINISH
F6 REMOVE EXISTING QUARRY TILE FLOORING AND COVE WALL BASE & PREP
EXIST. CONC SLAB TO RECEIVE NEW FLOOR FINISH
F7 REMOVE EXISTING 43"H WOOD WAINSCOTTING, AND WOOD WALL BASE. RATED
GYPSUM WALL TO REMAIN.
F8 REMOVE EXISTING 43"H WOOD WAINSCOTTING AND WOOD WALL BASE AROUND
THE PERIMETER OF COLUMN ON CUSTOMER SIDE, AND FRP WALL PANELS AND
QUARRY TILE COVE BASE ON SERVING SIDE.
F9 REMOVE EXIST. 24"H WALL TILE & WOOD CHAIRAIL
F10 REMOVE EXISTING 65"H WALL TILE AND COVE BASE.
F11 REMOVE EXIST. 43"H WOOD WALL WAINSCOTTING, WALL BASE, AND BRICK
VENEER. REPAIR WALLS AS REQUIRED AND PREPARE WALLS TO RECEIVE NEW
PAINT AND TILE FINISHES.
F12 REMOVE EXISTING RESILIENT BASE
F13 SALVAGE TILE BASE FOR REUSE.
F14 SALVAGE VENEER BRICK FOR REUSE.
F15 REMOVE EXISTING FRP WALL PANEL (7'-11"H) TO JOINT. REMOVE EXISTING
WOOD BASE, & PREP PORTION OF WALL TO RECEIVE NEW SCHEDULED
FINISHES.
F16 SAW-CUT EXISTING CONCRETE SLAB TO INSTALL NEW PLUMBING DRAIN LINES.
REFER PLUMBING DRAWINGS. INFILL TRENCH PER DETAIL ON A0800.
CO-ORDINATE EXTENT OF SLAB CUTTING WITH PLUMBING AND EQUIPMENT
REQUIREMENTS.
K1 REMOVE EXISTING HANDSINK, SOAP & PAPER TOWEL DISPENSERS & SALAVAGE
W/ CARE FOR REINSTALLATION.
K2 REMOVE WALK-IN REFRIGERATOR AND ALL APPURTENANCES & SALAVAGE W/
CARE FOR RELOCATION AND REINSTALLATION.
K3 REMOVE ALL EXISTING FOOD SERVICE BAR EQUIPMENT, INCLUDING SHELVING.
CONSULT OWNER FOR SALVAGE OR DISPOSAL INSTRUCTIONS.
M1 REMOVE ALL MILLWORK INCLUDING BUT NOT LIMITED TO: EXISTING BUILT-IN
BANQUETTE SEATING & WALL MOUNTED CUSHION BACK, PASS-THROUGH,
BUILT-IN BAR.
M2 REMOVE EXISTING 34"H CASEWORK
M3 REMOVE EXISTING 43"H BUILT-IN BAR, INCLUDING LAMINATE COUNTERTOP,
PARTIAL HEIGHT STUD WALLS, WOOD WAINSCOTTING AND TILED CONCRETE
FOOTSTEP ON THE EXTERIOR FACE, AND FRP PANELS AND QUARRY TILE BASE
ON THE INTERIOR FACE.
O1 REMOVE EXISTING WINDOWS, CASING AND STUD WALLS IN THEIR ENTIRETY TO
UNDERSIDE OF EXISTING BULKHEAD.
O2 REMOVE EXISTING WINDOWS, FRAMES, CASING. MAINTAIN STUD WALLS AND
PREP TO RECEIVE NEW STOREFRONT. SALVAGE BRICK VENEER FOR REUSE.
O3 REMOVE EXISTING WINDOWS, FRAMES, CASING AND STUD WALL BELOW.
COORDINATE WITH OPENING FOR NEW DOOR.
O4 REMOVE EXISTING 36"Wx84"H ALUM/GLASS ENTRY DOOR & FRAME, 18"Wx84"H SIDELITE, AND 56"Wx14"H ALUM/GLASS TRANSOM
O5 REMOVE EXISTING OVERHEAD COILING GRILLE.
S1 EXIST. FLOOR DRAIN TO BE REMOVED AND CAPPED. REFER TO PLUMBING
DRAWINGS.
S2 REMOVE EXISTING ELECTRICAL STUB UP.
W1 REMOVE EXISTING WALL, INCLUDING WOOD WAINSCOTTING, WALL BASE AND
WALL CAP.
W2 REMOVE PORTION OF EXISTING STUD WALL, INCLUDING GYPSUM BOARD, 43"H
WOOD WAINSCOTTING, & WOOD WALL BASE ON THE RATHSKELLER SIDE, AND
WALL TILE AND QUARRY TILE COVE BASE ON THE KITCHEN SIDE.
W3 DEMO WALL ONLY AS REQUIRED FOR INSTALLATION OF NEW ELECTRICAL
PANELS. PATCH AS REQUIRED TO MATCH ADJACENT FINISHES
W4 REMOVE EXISTING WALL BRACING. RECONSTRUCT WALL AS REQUIRED FOR
PERMANENT INSTALLATION.
W5 DEMO PORTION OF WALL FOR NEW DOOR.
0' 4' 8'
1" = 1'-0"D1
DEMOLITION DETAIL
1560 Wilson Blvd. Suite 200
P: 703.907.2300
F: 703.907.2050
Arlington, VA 22209
1 WORKING DRAWINGS R1 13 SEP 23
OUBO Review Stamp
Date = 12/11/2023
V D
V D
VD
VD
P
S S
SS
S
S S SS
C2
C2
C12
C1
TYP
DINING
AREA
THE
RATHSKELLER
EXISTING
CORRIDOR
EXISTING
KITCHEN
1201B
C8
C8 C1 C6
C8
C8
C6
C5 C5
C11
C13
C7
C1
K4 C10
C2
EXISTING
VESTIBULE
1000A
DINING
AREA
7' - 11"
GWB-1
9' - 11"
GWB-1
8' - 7"
EXIST.
S
S
S
C8
AREA NOT
IN SCOPE
V.I.F.
REFER TO OVERALL CORRIDOR CEILING PLAN FOR LIGHTING REMOVAL SCOPE
C3
C3
C3
C4C22
B2/A0800
GENERAL NOTES
1. ALL ITEMS TO BE REMOVED SHALL BE REMOVED ENTIRELY, AND AFFECTED
SURFACES PREPARED TO RECEIVE NEW CONSTRUCTION. CONTRACTOR TO
PATCH AND REPAIR ANY DEMOLISHED AREAS NOT TO BE COVERED BY NEW
CONSTRUCTION.
2. PROTECT ALL EXISTING WORK TO REMAIN. REPAIR AS NECESSARY ANY
DAMAGE TO REMAINING ITEMS WHICH OCCURS DURING DEMOLITION OR
CONSTRUCTION.
3. IN ALL WALLS AND CEILINGS SCHEDULED FOR REMOVAL, CONTRACTOR SHALL
DISCONNECT AT THE SOURCE ANY ANY ELECTRICAL CIRCUITS, AND CAP ALL
ABANDONED PLUMBING/UTILITIES BEHIND FINISHES, OR BELOW EXISTING
FLOOR. COMPLY WITH ALL APLICABLE CODES.
4. REFER TO MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR
EXISTING FIXTURES AND SERVICES TO BE REMOVED.
5. DEMOLITION IS NOT FULLY ILLUSTRATED ON DRAWINGS. PROVIDE DEMOLITION
AS REQUIRED TO ACCOMODATE NEW CONSTRUCTION.
6. ALL DIMENSIONS TO BE VERIFIED IN FIELD.
7. PATCH AND PREP ANY EXISTING FLOORS, WALLS, DOORS, DOOR FRAMES AND
CEILING TO RECEIVE NEW FINISHES.
8. DURING RENOVATION PROJECT, A FULL BUILDING FIRE WATCH SHALL BE
PROVIDED FOR ANY WORK THAT AFFECTS THE INTEGRITY OF THE FIRE ALARM
OR SPRINKLER SYSTEM. THIS INCLUDES ANY REMOVAL OF CEILING TILE
AROUND SPRINKLER HEADS THAT IS NOT REINSTALLED AT THE END OF THE
WORK DAY. FIRE WATCH SHALL BE PERFORMED BY A DEDICATED PERSON
AND SHALL FOLLOW THE PROCEDURES OUTLINED ON THE EHS WEBSITE. A
FIRE WATCH MAY NOT BE NEEDED IF A 2 HR CONSTRUCTION BARRIER IS
INSTALLED AROUND THE PERIMETER OF THE ENTIRE CONSTRUCTION AREA
AND PRIOR WRITTEN APPROVAL IS OBTAINED FROM GEORGE MASON AND
SFM.
9. CONTRACTOR TO PROVIDE QUALIFIED PERSONNEL TO PERFORM SPRINKLER
DRAIN DOWN AND RE-FLOW OF THE SPRINKLER SYSTEM. GMU WILL PROVIDE
ASSISTANCE DEMONSTRATING PROCEDURES UPON REQUEST.
10. REFER TO FOOD SERVICE EQUIPMENT DRAWINGS PREPARED BY OWNER'S
CONSULTANT FOR EQUIPMENT TO BE REMOVED, REUSED, OR REMAIN.
COORDINATE WITH OWBER FOR SALVAGE OR DISPOSAL INSTRUCTIONS.
11. REFER TO PLUMBING AND EQUIPMENT REQUIREMENTS TO COORDINATE FOR
NEW PLUMBING DRAIN LINES. SAW CUT EXISTING CONCRETE SLAB TO INSTALL
NEW PLUMBING DRAIN LINES. INFILL TRENCH PER DETAIL ON A0800.
12. REFER TO FIRE PROTECTION DRAWINGS FOR SPRINKLERS TO REMAIN,
REMOVE, OR RELOCATE.
13. EXISTING OFFICE SHALL BE OCCUPIED DURING CONSTRUCTION.
14. CONTRACTOR SHALL COMPLETELY AND CAREFULLY REMOVE ALL AV / IT
EQUIPMENT. OWNER SHALL HAVE FIRST RIGHT OF REFUSAL FOR DISPOSAL OF
EQUIPMENT.
2x2, ACT-1
2x4, ACT-2
GWB-1
CEILING LEGEND
AIR DEVICE, SUPPLY
AIR DEVICE, RETURN
SPEAKERS
2X4 LED FIXTURE
2X2 LED FIXTURE
CEILING-MOUNTED/PENDANT LIGHT FIXTURE
RECESSED DOWNLIGHT FIXTURE
WALL-MOUNTED EXTERIOR LIGHT
TRACK LIGHT
EXIT LIGHT, CEILING MOUNTED
EXIT LIGHT, WALL MOUNTED
EXISTING SPRINKLER HEAD
ACCESS DOOR
EXISTING FAUX WOOD BEAMS
OCCUPANCY SENSORP
CEILING FAN
S
EXISTING
VESTIBULE
1000A
DINING
AREA
REMOVE EXISTING FLUORESCENT LIGHTS AND REPLACE IN PLACE.
N
N
Checked by:Project No.:
Drawing Title:
© 2022 The Cannon Corporation.
T h e C a n n o n C o rp o ra ti o n
A ll ri g h ts r e s e rv e d N o p a rt o f th is d o c u m e n t m a y b e r e p ro d u c e d o r u ti liz e d i n a n y f o rm w it h o u t p ri o r w ri tt e n a u th o ri z a ti o n b y T h e C a n n o n C o rp o ra ti o n
GMU 181082; CD 006193.03
Rev. Description Date www.cannondesign.com
A
1 2 3 4 5 6
B
C
D
E
RATHSKELLAR DINING
SPACE RENOVATION
PROJECT
4469 Aquia Creek Ln Fairfax, VA
KEY PLAN
Project North VA State Grid North
WORKING DRAWINGS 04 AUG 2023
/2 /2
:5
:3
A M
D0701
DEMOLITION REFLECTED
CEILING PLAN
SW
0' 4' 8'
1/4" = 1'-0"B1
LEVEL 01 DEMOLITION REFLECTED CEILING PLAN
DEMOLITION KEYED NOTES:
NUMBER DESCRIPTION
C1 REMOVE ALL EXISTING CEILINGS, LIGHTS, AND APPURTENANCES. REMOVE ALL
EXISTING SPEAKERS AND WIRING. PREPARE FOR NEW MEP WORK AND
FINISHES.
C2 EXISTING CEILING AND LIGHT FIXTURES TO REMAIN, UNLESS NOTED
OTHERWISE
C3 REMOVE EXISTING ACOUSTICAL TILE CEILING, RECESSED LIGHT FIXTURES, AND
MECHANICAL REGISTERS. REFER TO FIRE PROTECTION DRAWINGS FOR
SPRINKLERS TO REMAIN, REMOVE OR RELOCATE.
C4 REMOVE EXISTING CEILING ABOVE VISIBLE CEILING.
C5 REMOVE EXISTING CEILING/WALL MOUNTED EXIT LIGHT
C6 REMOVE FAUX WOOD BEAMS
C7 REMOVE EXIST. PENDANT LIGHTING.
C8 REMOVE GYP BOARD @ EXISTING BULKHEAD AS NECESSARY TO PREPARE FOR
NEW MEP WORK. KEEP STUDS FOR REUSE.
C10 REMOVE & REINSTALL EXIST. CEILING TILES IN THIS AREA TO PREPARE FOR
NEW MEP WORK (REPRESENTED BY DASHED LINES)
C11 EXISTING BULKHEAD TO REMAIN
C12 REMOVE PORTION OF EXISTING GYPSUM BOARD BULKHEAD TO INSTALL NEW
SECURITY GRILL.
C13 REMOVE EXISTING RECESSED MOTORIZED OVERHEAD SECURITY GATE &
COMPONENTS.
C22 COMPLETELY REMOVE EXISTING GYPSUM/ PLASTER CEILING ASSEMBLY
INCLUDING ALL HANGERS AND SUPPORTS, LIGHT, GRILLES, SPEAKERS, SMOKE
DETECTORS, EXPANSION JOINTS ETC. COORDINATE WITH MECHANICAL/
ELECTRICAL/ PLUMBING FOR DEVICES TO REMAIN AND FOR THE INSTALLATION
OF NEW FIXTURES.
K4 EXIST. GREASE HOOD TO REMAIN
1560 Wilson Blvd. Suite 200
P: 703.907.2300
F: 703.907.2050
Arlington, VA 22209
0' 4' 8'
1/8" = 1'-0"A1
CORRIDOR DEMOLITION REFLECTED CEILING PLAN
1 WORKING DRAWINGS R1 13 SEP 23
OUBO Review Stamp
Date = 12/11/2023
F
P
S S SS
S
F
F
F
DPL (E) DPH
300KVA XFMR
(E) KILN
N
N
Checked by:Project No.:
Drawing Title:
© 2022 The Cannon Corporation.
T h e C a n n o n C o rp o ra ti o n
A ll ri g h ts r e s e rv e d N o p a rt o f th is d o c u m e n t m a y b e r e p ro d u c e d o r u ti liz e d i n a n y f o rm w it h o u t p ri o r w ri tt e n a u th o ri z a ti o n b y T h e C a n n o n C o rp o ra ti o n
GMU 181082; CD 006193.03
Rev. Description Date www.cannondesign.com
A
1 2 3 4 5 6
B
C
D
E
RATHSKELLAR DINING
SPACE RENOVATION
PROJECT
4469 Aquia Creek Ln Fairfax, VA
KEY PLAN
Project North VA State Grid North
WORKING DRAWINGS 04 AUG 2023
/2 /2
:3
:0
A
M
D0801
LEVEL 01 DEMOLITION
PLAN
SR
1. EXISTING DEVICE TO REMAIN.
2. REMOVE ALL EXISTING DEVICES THIS ROOM UNLESS OTHERWISE NOTED. MAINTAIN CONTINUITY OF CIRCUITS
TO AREAS NOT AFFECTED BY THE RENOVATION PROGRAM.
3. REMOVE EXISTING DEVICE AND ASSOCIATED BACKBOXES.
4. REMOVE EXISTING DEVICE. EXISTING BACKBOX AND PARTIAL CONDUIT EXTENSION TO BE REUSED.
5. REMOVE EXISTING LUMINAIRES THIS ROOM.
6. DISCONNECT AND REMOVE ALL EXISTING CEILING MOUNTED DEVICES AND LUMINAIRES THIS AREA, UNLESS
NOTED OTHERWISE.
7. DISCONNECT AND REMOVE EXISTING TRANSFORMER LINE SIDE DISCONNECT SWITCH. REMOVE EXISTING
FEEDER BACK TO MAIN SWITCHBOARD.
8. DISCONNECT AND REMOVE EXISTING 300KVA TRANSFORMER AND CONCRETE BASE.
9. RELOCATE EXISTING PANEL (KILN) AND ASSOCIATED BRANCH CIRCUITS 12'' TO THE RIGHT OF ITS CURRENT
LOCATION.
10. EXISTING PANEL (DPL) TO BE DISCONNECTED AND REMOVED. ALL EXISTING FEEDERS CURRENTLY CONNECTED
SHALL BE DISCONNECTED AND PARTIALLY BE REMOVED TO ABOVE THE PANEL.
11. EXISTING LOAD SIDE DISCONNECT SWITCH, AND LOAD SIDE FEEDER TO BE DISCONNECTED AND REMOVED.
12. EXISTING ICE MAKER TO BE DISCONNECTED, REMOVED AND RELOCATED. SEE NEW WORK PLAN.
13. EXISTING CORRIDOR LIGHTING SHALL BE DISCONNECTED AND REMOVED. NEW FIXTURES SHALL OCCUPY SAME POSITION IN CEILING. EXISTIGN LIGHTING CONTROL SHALL REMAIN IN PLACE, SEE DRAWING E0101 FOR NEW
FIXTURE LAYOUT.
14. REMOVE EXISTING RECEPTACLE AND DEVICE PLATE. EXISTING BACK-BOX AND WIRING SHALL REMAIN.
KEYED NOTES :
A. REMOVE ALL ELECTRICAL EQUIPMENT ON OR IN EXISTING WALLS, CEILINGS AND PARTITIONS WHICH ARE TO BE DEMOLISHED. REMOVE ALL EXPOSED PORTIONS OF BRANCH CIRCUIT AND CONTROL VOLTAGE WIRING AND CONDUITS.
B. WHERE EXISTING WALLS ARE TO REMAIN, REMOVE ALL EXPOSED RACEWAYS, SURFACE AND RECESSED OUTLET BOXES, ETC. WHICH ARE NOT TO BE REUSED. WHERE NEW CONDUITS AND OUTLETS ARE TO BE ADDED TO EXISTING WALLS IN
FINISHED ROOMS, THEY SHALL BE CONCEALED BY CUTTING AND PATCHING THE WALLS.
C. UTILIZE EXISTING OUTLET BOXES AND RACEWAY SYSTEMS WHEREVER PRACTICAL IN RENOVATION AREAS. WHERE SUCH EXISTING OUTLET BOXES ARE USED, INSTALL NEW WIRING DEVICES, COVERPLATES, AND WIRING. SPECIAL
COVERPLATES MAY BE REQUIRED TO SUIT CONDITIONS.
D. REARRANGE EXISTING CONDUITS AND WIRING TO ACCOMMODATE NEW CIRCUIT ARRANGEMENTS INDICATED AND TO
MAINTAIN CONTINUITY OF EXISTING CIRCUITS FEEDING DEVICES THAT ARE TO REMAIN.
E. BE RESPONSIBLE TO REMOVE AND REINSTALL EXISTING ELECTRICAL EQUIPMENT TO ACCOMMODATE THE WORK OF OR
DISTURBED BY ALL TRADES.
F. STOCKPILE REMOVED LUMINAIRES, POWER AND COMMUNICATION DEVICES ON JOB SITE FOR REUSE UNTIL TIME OR PROJECT CLOSEOUT, THEN REMOVE THOSE FROM SITE THAT THE OWNER DOES NOT WISH TO SALVAGE.
G. EXISTING DEVICE LOCATIONS WERE IDENTIFIED AS COMPLETELY AS POSSIBLE BY A SITE SURVEY AND BY RECORD DOCUMENTS AS AVAILABLE. BE RESPONSIBLE FOR PROPER DEMOLITION AND REWORK OF DEVICES NOT SHOWN ON
DRAWINGS TO CONFORM WITH INTENT OF DOCUMENTS.
H. ALL EXISTING FIRE ALARM SYSTEM AND DEVICES LOCATED OUTSIDE OF AREA OF CONSTRUCTION SHALL BE MAINTAINED.
FIRE ALARM SYSTEM AND DEVICES WITHIN AREA OF CONSTRUCTION SHALL BE DEACTIVATED DURING CONSTRUCTION.
GENERAL DEMOLITION NOTES:
1/8" = 1'-0"
ELECTRICAL DEMOLITION PLAN - POWER AND LIGHTING
1560 Wilson Blvd. Suite 200
P: 703.907.2300
F: 703.907.2050
Arlington, VA 22209
3 2
1 WORKING DRAWINGS R1 13 SEP 2023
11/22/23
OUBO Review Stamp
Date = 12/11/2023
3" EX GW3" EX W
4" EX GW
3" EX GW
4" EX GW
4" EX GW
4" EX GW
N
N
Checked by:Project No.:
Drawing Title:
© 2022 The Cannon Corporation.
T h e C a n n o n C o rp o ra ti o n
A ll ri g h ts r e s e rv e d N o p a rt o f th is d o c u m e n t m a y b e r e p ro d u c e d o r u ti liz e d i n a n y f o rm w it h o u t p ri o r w ri tt e n a u th o ri z a ti o n b y T h e C a n n o n C o rp o ra ti o n
GMU 181082; CD 006193.03
Rev. Description Date www.cannondesign.com
A
1 2 3 4 5 6
B
C
D
E
RATHSKELLAR DINING
SPACE RENOVATION
PROJECT
4469 Aquia Creek Ln Fairfax, VA
KEY PLAN
Project North VA State Grid North
WORKING DRAWINGS 04 AUG 2023
/2 /2
:0
:5
P M
PD0100
UNDERSLAB - PLUMBING
DEMOLITION PLAN
DK
1/4" = 1'-0"
UNDERSLAB PLUMBING DEMOLITION PLAN
1560 Wilson Blvd. Suite 200
P: 703.907.2300
F: 703.907.2050
Arlington, VA 22209
1. DISCONNECT AND REMOVE 3" GREASE WASTE (GW) TO POINT INDICATED, CAP PIPING BELOW
SLAB.
2. DISCONNECT AND REMOVE 2" GREASE WASTE (GW) TO POINT INDICATED AND CAP.
3 4" GREASE WASTE(GW) UP TO EXITING 4" FLOOR CLEAN OUT (FCO).
4. 3" WASTE - UP TO 3" FLOOR SINK.
5. 4" GREASE WASTE (GW) CONTINUES TO EXISTING GREASE INTERCEPTOR.
6. 3" GREASE WASTE (GW) - UP TO EXISTING MOP BASIN.
KEYED NOTES
1 WORKING DRAWINGS R1 13 SEP 2023
OUBO Review Stamp
Date = 12/11/2023
EX V
EX FS
EX FD
EX FCO
EX FS
EX SK
EX FD
EX FCO
EX SKEX SK
EX SK
1 1
FS
FS
FS
FS
FS
FS(ETR)
N
N
Checked by:Project No.:
Drawing Title:
© 2022 The Cannon Corporation.
T h e C a n n o n C o rp o ra ti o n
A ll ri g h ts r e s e rv e d N o p a rt o f th is d o c u m e n t m a y b e r e p ro d u c e d o r u ti liz e d i n a n y f o rm w it h o u t p ri o r w ri tt e n a u th o ri z a ti o n b y T h e C a n n o n C o rp o ra ti o n
GMU 181082; CD 006193.03
Rev. Description Date www.cannondesign.com
A
1 2 3 4 5 6
B
C
D
E
RATHSKELLAR DINING
SPACE RENOVATION
PROJECT
4469 Aquia Creek Ln Fairfax, VA
KEY PLAN
Project North VA State Grid North
WORKING DRAWINGS 04 AUG 2023
/2 /2
:0
:5
P M
PD0101
LEVEL 01 - PLUMBING
DEMOLITION PLAN
DK
1/4" = 1'-0"
LEVEL 01 SANITARY DEMOLITION PLAN
1560 Wilson Blvd. Suite 200
P: 703.907.2300
F: 703.907.2050
Arlington, VA 22209
1. DISCONNECT & REMOVE EXISTING FIXTURE & ASSOCIATED FS, GW, & VENT PIPING TO POINT
INDICATED, CAP & ABANDON INACCESSIBLE PIPING BELOW EXISTING TO REMAIN SLAB.
2. DISCONNECT & REMOVE EXISTING FIXTURE & ASSOCIATED GW & VENT PIPING TO POINT
INDICATED.
3. DISCONNECT & REMOVE EXISTING FLOOR SINK & ASSOCIATED GW & VENT PIPING TO POINT
INDICATED. CAP & ABANDON INACCESSIBLE PIPING BELOW EXISTING SLAB.
4. DISCONNECT & REMOVE EXISTING 2" VENT TO POINT INDICATED ABOVE CEILING. CAP OR
PREPARE PIPING FOR NEW CONNECTION AS REQUIRED.
5. EXISTING TO REMAIN FLOOR SINK (FS).
6. EXISTING TO REMAIN MOP SINK (MS).
7. INDIRECT WAST PIPING FROM FIXTURES TO FLOOR SINK TO BE REMOVED.
8. DISCONNECT AND REMOVE EXISTING FLOOR DRAIN.
9. DISCONNECT & REMOVE EXISTING MOB BASIN IN ITS ENTIRETY. ALL ASSOCIATED HOT& COLD WATER AND VENT PIPING SHALL BE REMOVE BACK TO 1'-0" OF MAIN AND CAPPED. WASTE PIPING
SHALL BE REMOVE TO POINT BELOW FLOOR AND CAPPED.
KEYED NOTES
1 WORKING DRAWINGS R1 13 SEP 2023
OUBO Review Stamp
Date = 12/11/2023
EX CW
EX HW
EX HWR
E X
H W
R
E X
H W
E X
C W
EX SK
EX SK
EX SK
EX SK
EX SK
3/4"3/4"3/4"
1"
1"
3/4"
4 4
EX MB 7
N
N
Checked by:Project No.:
Drawing Title:
© 2022 The Cannon Corporation.
T h e C a n n o n C o rp o ra ti o n
A ll ri g h ts r e s e rv e d N o p a rt o f th is d o c u m e n t m a y b e r e p ro d u c e d o r u ti liz e d i n a n y f o rm w it h o u t p ri o r w ri tt e n a u th o ri z a ti o n b y T h e C a n n o n C o rp o ra ti o n
GMU 181082; CD 006193.03
Rev. Description Date www.cannondesign.com
A
1 2 3 4 5 6
B
C
D
E
RATHSKELLAR DINING
SPACE RENOVATION
PROJECT
4469 Aquia Creek Ln Fairfax, VA
KEY PLAN
Project North VA State Grid North
WORKING DRAWINGS 04 AUG 2023
/2 /2
:0
:5
P M
PD0201
LEVEL 01 - DOMESTIC
WATER FLOOR PLAN
DK
1/4" = 1'-0"
LEVEL 01 DOMESTIC WATER DEMOLITION PLAN
1560 Wilson Blvd. Suite 200
P: 703.907.2300
F: 703.907.2050
Arlington, VA 22209
1. DISCONNECT AND REMOVE EXISTING FIXTURE & ASSOCIATED CW, HW & HWR PIPING IN ITS
ENTIRETY.
2. DISCONNECT & REMOVE EXISTING 3/4" CW, HW & HWR PIPING TO POINT INDICATED ABOVE
CEILING. CAP OR PREPARE PIPING FOR NEW CONNECTION AS REQUIRED.
3. DISCONNECT & REMOVE EX 1/2" CW & HW PIPING TO POINT INDICATED ABOVE CEILING. CAP
OR PREPARE PIPING FOR NEW CONNECTION AS REQUIRED.
4. EXISTING CW, HW & HWR PIPING CONTINUE TO EXISTING DOMESTIC WATER SYSTEM.
5. EXISTING CW & HW PIPING CONTINUES TO EXISTING DOMESTIC WATER SYSTEM.
6. DISCONNECT AND REMOVE PIPING TO POINT INDICATED AND CAP.
7. EXISTING TO REMAIN MOP BASIN (MB).
KEYED NOTES
1 WORKING DRAWINGS R1 13 SEP 2023
OUBO Review Stamp
Date = 12/11/2023
C
LOUVER
ROOM NAME
AND NUMBER 1125
ROOM NAME
ROOM NUMBER
SHEET…
This is the start of the file's text. The full file is on GovTribe.