15toilet_1-_roof_details-Layout1.pdf

PDF 113 KB Posted

Attached to
ROCEOVRY: Little Tesuque Improvements Project
Solicitation number
AG-9702-S-10-0147
Issued by

About this file

Toilet Building Roof Details

View the file

Other files

File Type Posted
16Toilet_Building_Details-Layout1.pdf PDF
31Split-faced Retaining wall-Layout1.pdf PDF
05_ARRA_Little_Tesuque_PG_Toilet_Removal.pdf PDF
02_Site Plan.pdf PDF
22Kiosk-Message Board-Kiosk Message Board Elevations.pdf PDF
11_Toilet Building Section Floor Plan.pdf PDF
30Boulder Placement Rip Rap-Layout1.pdf PDF
13_Toilet Building oof_framing_plan-Layout1.pdf PDF
01_Title Sheet index.pdf PDF
18toi_bldg_hardware_schedule-Layout1.pdf PDF
27Trail Clearing-Layout1.pdf PDF
10_Toilet Building Section Slab Plan.pdf PDF
Attachment 3_Fire Plan_ LittleTesuque.doc DOC document
09_Toilet Building Section Foundation.pdf PDF
06_Toilet Building Section AA.pdf PDF
19Trashpad-Layout1.pdf PDF
32Shrub Planting-Planting Det..pdf PDF
Attachment 5_Standard Form 24.pdf PDF
03_Demolition Plan.pdf PDF
Attachment 4_Wage DeterminationNM1.pdf PDF
04_Toilet Building Site.pdf PDF
23Kiosk-Message Board-Kiosk - Roof Framing Support Post.pdf PDF
AG-9702-S-10-0147 RFP.doc DOC document
12_Toilet Building Section Walkway.pdf PDF
21ARRASignDetails-Sign Details.pdf PDF
05_Shelter Site.pdf PDF
26hardened_trail_typs-Layout1.pdf PDF
20Picnic_table-Layout1.pdf PDF
14roof_plan-Layout1.pdf PDF
08_Toilet Building Section Elevation.pdf PDF
28Master_Plan-Picnic Unit.pdf PDF
Attachment 1_Little Tesuque_ Specs.doc DOC document
07_Toilet Building Section BB.pdf PDF
17toilet_2_-_door_stuff-Layout1.pdf PDF
24draindip-Layout1.pdf PDF
25RegulatorySign-Layout1.pdf PDF
29FireRing GroupFireRing-Layout1.pdf PDF
Attachment 3_Fire Plan_ LittleTesuque.doc DOC document
Attachment 4_Wage DeterminationNM1.pdf PDF
Attachment 2 File.zip ZIP file
Attachment 1_Little Tesuque_ Specs.doc DOC document
AG-9702-S-10-0147 RFP.doc DOC document
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1" x 6" S.1.S. Pine T&G ceiling - finish

SKYLIGHT DETAIL

NO SCALE

seal to watertight fiinish

Skylight -- flash and plywood roof

Propanel metal roof

Cant strip

Flashing, 26 GA.

deck

1/2" M.D.O.

30 # Roofing felt

R-19 Batt insulation

2" x 6" Framing, see roof plan

Joist hanger

1" x 1" Corner trim

Blocking

Curb

NO SCALE

TYPICAL VALLEY CONDITION

flashing

Panel

Valley

3 Layers min. #15 felt and valley flash top layer of felt of caulk between

Continuous bead

J-clip

NOTE:

Ensure that valley is not blocked by roof panel ridges

1" x 6" S.1.S. T & G Pine decking

1/2" x 6" Anchor bolt at 24" O.C.

2- #4 Continuous bars

ROOF OVERHANG DETAIL

5/8" Rough sawn plywood soffit block to close gap Silicone sealant against

Panel roof sealant

Propanel metal roof

1" x 8" Fascia board

1/2" M.D.O. plywood

30# Roofing felt

Bond beam

R-19 Batt insulation

2" x 4" Rim joist

Fiberglass panel

3/8" Plywood

SCALE: 3/4" = 1'-0"

Metal sheathing to match roofing panel

Metal drip edge to match roofing panel

3. Valleys and flashing to match roof materials.

2. Flash and seal all roof penetrations to

1. Skylight to be installed per manufacturer's

NOTES:

4. S1S = surface one side recommendations.

form a weathertight seal.

U.S. DEPARTMENT OF AGRICULTURE

GAT FON

SOUTHWESTERN REGION

FOREST SERVICE

A P

E D

EMT

R

E R

U

TLUCIR

R-3 Item No.Project Name

Forest

Sheet

Scale

Sheet Title

A.16 Toilet Building - Roof Details

Little Tesuque Improvements

Santa Fe National Forest

As Shown 15 of 32

10168 t o i l e t r o o f d e t a i l s d w g

Layout1

File details come from the government source that posted it. Updated .