Bldg_4732_Asbestos_Survey_Report_Final.pdf

PDF 8 MB Posted

Attached to
Central Steam Distribution Replacement Phase 2 Federal contract opportunity
Solicitation number
80MSFC18B0003
Issued by
National Aeronautics and Space Administration Marshall Space Flight Center

About this file

Bldg 4732 Asbestos Survey Report Final

View the file

Other files for this federal contract opportunity

Other files attached to Central Steam Distribution Replacement Phase 2, newest first.
File Type Posted
Abstract_of_Bids,_80MSFC18B0003.pdf PDF
IFB_80MSFC18B0003,_Posted_Copy,_Aug_9,_2018_REVISED_BLOCK_13.pdf PDF
IFB_80MSFC18B0003,_Amendment_4,_REVISED_BLOCKS_11_&_13.pdf PDF
IFB_80MSFC18B0003,_Amendment_4.pdf PDF
IFB_80MSFC18B0003,_Posted_Copy,_Aug_9,_2018.pdf PDF
33_16_15_-_Thermal_Energy_Storage_Tank_Specification,_Amendment_4.pdf PDF
Revised_Plans,_FAC-5071,_80MSFC18B0003.pdf PDF
IFB_80MSFC18B0003,_Amendment_3.pdf PDF
Army_and_NASA_Site_Access_Control_Boundaries_Map.pdf PDF
Bid_Instructions_for_IFB_80MSFC18B0003,_Amendment_3.pdf PDF
Attendees_at_Site_Visit,_June_20,_2018,_IFB_80MSFC18B0003.pdf PDF
IFB_80MSFC18B0003,_Amendment_2.pdf PDF
IFB_80MSFC18B0003,_Posted_Copy,_July_20,_2018.pdf PDF
Bldg_4704_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4483_Asbestos_Survey_Report_Final.pdf PDF
IFB_80MSFC18B0003,_Posted_Copy,_June_26,_2018.pdf PDF
80MSFC18B003,_Amendment_1.pdf PDF
Bldg_4711_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4493_Asbestos_Survey_Report_Final.pdf PDF
Specifications_FAC-M5066,_80MSFC18B0003.pdf PDF
Plans,_FAC-5066,_80MSFC18B0003.pdf PDF
Bldg_4776_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4464_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4727_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4312_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4723_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4491_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4306_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4733_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4747_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4777_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4705_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4738_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4485_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4702_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4715_Asbestos_Survey_Report_Final.pdf PDF
Specifications_FAC-M5071,_80MSFC18B0003.pdf PDF
Plans,_80MSFC18B0003.pdf PDF
IFB_80MSFC18B0003.pdf PDF
Bid_Instructions_for_IFB_80MSFC18B0003.pdf PDF
Show all 40

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

General Asbestos Survey for Asbestos-Containing Materials

Prepared for:

Marshall Space Flight Center, AL

Building 4732 Marshall Space Flight Center

GSE - 013

October 31, 2008

Prepared by

Great Southern Engineering, Inc.

3795 Gordon Terry Parkway

Trinity, Alabama 35673

TABLE OF CONTENTS

1. Introduction

2. Summary

2.1. Suspect ACMs

2.2. Recommendations

3. Survey Scope

4. Limitations

5. Survey and Sample Collection Procedure

6. Previous Survey / Plans Review

7. Suspect ACM Materials Not Sampled

8. Survey Sampling Results

9. Appendices

Task Order GSE 013 Page 1 of 26

GENERAL ASBESTOS SURVEY OF

Building 4732, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama

1. Introduction

In accordance with GSE Task Order No.GSE-013 dated April 21, 2008, Great Southern Engineering, Inc. (GSE) has performed an asbestos survey of Building 4732 located at George C.

Marshall Space Flight Center, Marshall Space Flight Center, Alabama. The 26,773 square feet building was identified to have been originally constructed in 1943. A total of 72 samples were collected from the building.

The objective of the Asbestos Survey is to determine the location and quantity of asbestos-containing materials at the Property building.

GSE’s Scope of Work included:

Visual inspection and identification of suspect asbestos-containing materials (ACMs) in the Property building and collected a representative number of samples for analysis.

As part of this asbestos survey, GSE personnel collected samples of all suspect friable and suspect damaged non-friable building materials at the Property. The remaining suspect non-friable materials were not be sampled as part of this asbestos survey

Estimated quantities and locations of ACM.

Assessed the condition of the ACM identified.

Assigned a hazard rating to each type of ACM.

This report has been prepared for the use of George C. Marshall Space Flight Center. Our investigation was performed using the degree of care and skill ordinarily exercised under similar circumstances by professional consultants practicing in this or similar localities. No other warranty or guarantee, expressed or implied, is made as to the conclusions included in this report.

Task Order GSE 013 Page 2 of 26

Building 4732, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama

The GSE, Inc. did not perform destructive sampling procedures at the site; therefore, regardless of the thoroughness of this survey, it is possible that suspected asbestos-containing materials (ACMs) might exist in the building beneath the floors, behind walls, within pipe chases, or in other inaccessible locations. If, during renovation or demolition activities, materials not addressed in this survey are discovered, these materials should be sampled and analyzed for asbestos content prior to disturbance.

Surveyed by:

William F. Ystueta

University of Alabama Safe State Program Accredited Inspector

Accreditation #AIN0508Y6144

Jeff R Smith

University of Alabama Safe State Program Accredited Inspector/Management Planner

Accreditation #APL0408S7033

Written by:

Manju Ramasamudra

University of Alabama Safe State Program Accredited Inspector/Management Planner

Accreditation #APL0308R5089

Task Order GSE 013 Page 3 of 26

Building 4732, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama

2. Summary

GSE performed an Asbestos Survey and Hazard Assessment at Building 4732 in Marshall Space Flight Center, Alabama on July 30, September 6, and October 19, 2008. Sample collection was completed by licensed personnel – William F. Ystueta and Jeff R Smith. The following report summarizes the independent conclusions representing GSE’ best professional judgment based on information and data available to us during the course of this survey. Factual information regarding operations, conditions, and tests data provided by the client, owner or their representative has been assumed to be correct and complete. Additionally, the conclusions presented are based on the conditions that existed on the date(s) of the assessment.

The 26,773 square feet building was identified to have been originally constructed in 1943. A total of 72 samples were collected from the building. Six (6) Homogeneous materials were identified as asbestos-containing materials. A summary of the samples collected for this area and corresponding analytical results is presented below.

Sample Description

Sample

ID

Building Number

Sample Material

ACM

Quantity

4732 22 Pipe Insulation Valve Covering Cloth 300 LF

Room Number Grid Numbers 128 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4

131 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4

132 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4

136 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4

150 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4

152 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4

153 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4

154 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4

155 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4

160 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4

Sample

ID

Building Number

Sample Material

ACM

Quantity

4732 34 Pipe Insulation Hard White Pipe Elbows 100 Elbows

Room Number Grid Numbers 128 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4

131 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4

132 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4

136 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4

150 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4

152 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4

153 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4

154 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4

155 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4

160 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4

Sample Description

Sample

ID

Building Number

Sample Material

ACM

Quantity

4732 61 12" x 12" Floor Tile Brown with White Streaks 325 SF

Room Number Grid Numbers 135 F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4

Sample

ID

Building Number

Sample Material

ACM

Quantity

4732 67 12" x 12" Floor Tile Beige with rown speckles 6,300 SF

Room Number Grid Numbers 128 F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4

130 F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4

130A F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4

131 F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4

132 F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4

136 F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4

HW131E103 F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4

Sample Description

Sample

ID

Building Number

Sample Material

ACM

Quantity

4732 70 12" x 12" Floor Tile Brown with brown and white speckles 1,050 SF

Room Number Grid Numbers 129 F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4

129A F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4

Sample Description

Sample

ID

Building Number

Sample Material

ACM

Quantity

4732 73 9" x 9" Floor Tile Dark Brown with Maroon Streaks 10 SF

Room Number Grid Numbers 135 F1-1, F1-2

WL1-1

WR2-1

WR1-1

WL3-1

WL2-1

WR4-1

WR3-1

F1-1 F2-1 F3-1 F4-1

C1-1 C2-1 C3-1 C4-1

C1-2

C1-3

C1-4

C2-2

C2-3

C2-4

C3-2

C3-3

C3-4

C4-2

C4-3

C4-4

WR4-2

WR4-3

WR4-4

WR3-2

WR3-3

WR3-4

WR2-2

WR2-3

WR2-4

WR1-2

WR1-3

WR1-4

F4-2

F4-3

F4-4

F3-2

F3-4

F2-2

F2-3

F2-4

F1-2

F1-3

F1-4

WL1-2

WL1-3

WL1-4

WL2-2

WL2-3

WL2-4

WL3-2

WL3-3

WL3-4

WL4-2

WL4-3

WL4-4

F3-3

WL4-1

WF4-1 WF4-2 WF4-3 WF4-4

WF3-1

WF2-1

WF1-1

WF3-2

WF2-2

WF1-2

WF3-3

WF2-3

WF1-3

WF3-4

WF2-4

WF1-4

WE4-1WE4-2WE4-3WE4-4

WE3-1

WE2-1

WE1-1

WE3-2

WE2-2

WE1-2

WE3-3

WE2-3

WE1-3

WE3-4

WE2-4

WE1-4

Map Document: (G:\asbestos\Asbestos_Room_grid.mxd)

1. Note: Entry wall depicted is as seen from inside the room, therefore grid WE4-4 is located at the top left corner of wall. The main entry door is located within the entry wall.

2. Entry wall location shall be described as N (North) S (South) E (East) or W (West) as seen from the inside of the room. Utilizing the facilities data book, N is located at the top of page, S at bottom of page, E at right of page and W and left of page regardless of bearing shown on drawing for all buildings. (The directional bearing symbol is pointing to either NE or NW for approximately 29 buildings in the facilities data book. Consider these NE or NW bearings as being Plan N when identifying the direction of the entry wall.)

The only exception is building 4705, this drawing shall be oriented towards North as shown on drawing.

3. Type of grid system uses 4 grids by length and 4 grids by width irrespective of the room size.

Grid: C - ceiling, WF - far wall, WE - entry wall, WL - left wall, WR - right wall, F - floor

Asbestos Survey Room Grid Note: Asbestos containing material above the ceiling should be noted on the ceiling grid

Far Wall Entry Wall

Far Wall

WL1-1

WR2-1

WR1-1

WL3-1

WL2-1

WR4-1

WR3-1

WR4-2

WR4-3

WR4-4

WR3-2

WR3-3

WR3-4

WR2-2

WR2-3

WR2-4

WR1-2

WR1-3

WR1-4

WL1-2

WL1-3

WL1-4

WL2-2

WL2-3

WL2-4

WL3-2

WL3-3

WL3-4

WL4-2

WL4-3

WL4-4

WL4-1

C1-1 C2-1 C3-1 C4-1

C1-2

C1-3

C1-4

C2-2

C2-3

C2-4

C3-2

C3-3

C3-4

C4-2

C4-3

C4-4

WF4-1 WF4-2 WF4-3 WF4-4

WF3-1

WF2-1

WF1-1

WF3-2

WF2-2

WF1-2

WF3-3

WF2-3

WF1-3

WF3-4

WF2-4

WF1-4

WE4-1WE4-2WE4-3WE4-4

WE3-1

WE2-1

WE1-1

WE3-2

WE2-2

WE1-2

WE3-3

WE2-3

WE1-3

WE3-4

WE2-4

WE1-4

F1-1 F2-1 F3-1 F4-1

F4-2

F4-3

F4-4

F3-2

F3-4

F2-2

F2-3

F2-4

F1-2

F1-3

F1-4

F3-3

Map Document: (G:\asbestos\Asbestos_Hall_grid.mxd)

1. Note: Entry wall and far wall are optional; there maybe neither that are identified in the hallway. Entry wall depicted is as seen from inside the room, therefore grid WE4-1 is located at the top left corner of wall.

2. Type of grid system uses 4 grids by length and 4 grids by width irrespective of the hall size.

3. The identification of hallway segments will be determined by the end rooms. Hallways will be measured from South to North and from East to West Ex. Room most south of hallway is Room 107 and room most North of hallway is Room 200. Using H as the designation of hallway. The identification of hallway is HS107N200. Likewise from east to west would be HE107W200. The room number sequencing is arbitrary; Ex. HE200W107 would be acceptable. NS&EW are used to distinguish between vertical and horizontal run corridors on drawings.

4. Utilizing the facilities data book, N is located at the top of page, S at bottom of page, E at right of page and W and left of page regardless of bearing shown on drawing for all buildings. (The directional bearing symbol is pointing to either NE or NW for approximately 29 buildings in the facilities data book. Consider these NE or NW bearings as being Plan N when identifying the hallway number.) The only exception is building 4705, this drawing shall be oriented towards North as shown on drawing.

Grid: C - ceiling, WF - far wall, WE - entry wall, WL - left wall, WR - right wall, F - floor

Asbestos Survey Hallway Grid Note: Asbestos containing material above the ceiling should be noted on the ceiling grid

Far Wall Entry Wall

Far Wall Room XXXBeginning

Room YYY N or W

S or E

Task Order GSE 013 Page 4 of 26

Building 4732, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama

2.1. Suspect ACMs

The following information is included for informational purposes:

A. The following suspect asbestos-containing materials were not sampled as part of this scope of work:

Suspect fibrous electrical cable covering (danger of electrocution) were not sampled.

These materials are not subject to regulation under NESHAP for demolition and renovation as long as they are in good condition and are not subject to sanding, grinding, cutting, or abrading.

Since ordinary demolition activities do not include sanding, grinding, cutting, and abrading, these materials may remain in place during building demolition, as long as they remain in good condition and are not friable.

If the material is in poor condition and is friable at the time of demolition or renovation, or if it will be subjected to sanding, grinding, cutting, or abrading, it should first be removed by a licensed asbestos removal contractor and disposed of as asbestos-containing waste.

When removing asphalt-roofing products, the material should be removed using a method that does not subject the material to sanding, cutting, grinding, or abrading (hand tools).

Asbestos-containing roofing may be disposed of as construction debris.

Task Order GSE 013 Page 5 of 26

Building 4732, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama

2.2. Recommendations

The following additional actions are recommended:

The identified asbestos-containing 12” X 12” brown with white streaks floortile, black mastic associated with 12” X 12” beige with brown speckles floortile, 12” X 12” brown with brown and white speckles floortile and associated black mastic, 9” X 9” dark brown floortile and associated black mastic, hard pipe elbow insulations, and valve insulation with white mastic are in good condition. MSFC (Property owner/Operator) should develop and implement an Operations and Maintenance (O&M) Program. In addition suspect asbestos-containing materials in the form of carpet below floortiles, caulking on exterior walls, grout on exterior block walls, electrical cable covering, fire doors, window caulking, mirror mastic, leveling compound below ceramic tile flooring, and duct vibration joints were not sampled as a part of this assessment. These materials can be maintained as part of the asbestos O&M Program. A properly designed O&M Program is sufficient to maintain the Project in accordance with current regulatory standards and sound business practice. ACM maintained with an O&M Program can remain in place, provided the ACM and suspect ACM remain intact and undisturbed.

Task Order GSE 013 Page 6 of 26

Building 4732, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama

3. Survey Scope

This survey was conducted for the purpose of identifying asbestos-containing materials (ACM) throughout the building and to conduct a hazard assessment on existing ACM. The survey was non-destructive in nature and limited only to those areas that were readily accessible.

Specific areas to which access was limited by occupant request, unavailability of keys, or by site conditions included the following:

Behind the walls

Beneath the floors

Any suspect ACM not sampled as part of the assessment and if any additional suspect materials were to be identified behind walls and beneath the floors should be sampled prior to repair, renovation, or demolition activities.

Task Order GSE 013 Page 7 of 26

Building 4732, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama

4. Limitations

GSE did not attempt to disassemble mechanical equipment, open pipe chases or assess materials within wall voids. Regardless of the thoroughness of a survey, the possibility exists that some areas containing asbestos were not identified, inaccessible or different from those at specific locations. The findings and opinions presented are relative to the dates of our site work and should not be relied upon to represent conditions at substantially later dates due to changes in the condition ACM may change over time, renovations and repairs.

This report is for the exclusive use of the client and its agents and use by any unauthorized parties in whole or in part, except as directed by legal jurisdiction, is at the sole risk of the user.

If this assessment includes reliance on work products and/or documents prepared by others, GSE has no responsibility for the accuracy of information contained therein.

Although this assessment has attempted to identify the presence or absence of ACM, potential sources of ACM may have escaped detection due to: (1) the scope of this assessment, (2) the inaccuracy of records, interviews, work products or documents made available to GSE for this report, (3) the presence of undetected or unreported renovations and repairs, (4) inaccessible areas, and/or (5) deliberate concealment of detrimental information.

Estimates presented in this report are based upon observations during the survey and owner-provided information. These reasonable estimates may be affected by unanticipated conditions potentially present in inaccessible or un-surveyed areas. GSE does not warrant or guarantee the quantity estimates. The use of such estimates shall be at the user's own risk and shall constitute a release and agreement to defend and indemnify GSE from and against any liability. If questions arise during the planning for renovation, demolition, or other construction activities, GSE should be notified to permit review of the data and present recommendations.

Interior of the following rooms were inaccessible during our Asbestos Survey on July 30, September 6, and October 19, 2008: None.

Task Order GSE 013 Page 8 of 26

Building 4732, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama

5. Survey and Sample Collection Procedure

Based on United States Environmental Protection Agency (USEPA) guidance documents, GSE considered all material applications identified during the visual assessment were suspect ACM and sampled as described below.

Bulk samples were collected of any materials, which were suspected of containing asbestos with the exception of fire doors. Fire doors were not sampled because the damage caused by sampling would render these materials friable and may also void the fire rating. Since these materials were not sampled, they should be assumed to be asbestos containing, unless sampled and proven otherwise. Sampling of these assumed ACMs should be performed prior to any renovation or other activity that may cause a material disturbance.

Samples of the remaining suspect ACM were taken in accordance with USEPA recommendations.

The number and location of samples collected was based on the type of material, the manner of application, and the homogeneity of the ACM (similarity of color, texture, and type). Each sample was collected and placed into an individual sample container. The sample location was noted on the field survey form and assigned an individual identification number. This number was affixed to the sample container as the sample was collected. The survey form was also used to note the material type and general condition of the material. During the inspection, each suspect material's accessibility, location, and friability were recorded. This information was used to assess the potential hazard of the ACM and to prioritize response action recommendations.

The USEPA defines asbestos-containing materials (ACM) as those that contain greater than one percent asbestos. Friable materials are defined as those that can be crumbled or reduced to powder by hand pressure.

GSE utilized the “positive-stop” method of sample analysis. In this method, analysis is stopped on a group of samples once the first positive (e.g., greater than 1% asbestos) sample is analyzed.

According to the USEPA, if one sample of a homogenous material is identified to be asbestos containing, the entire material must be considered asbestos containing. By using the positive-stop method, GSE reduces the Client’s laboratory analysis cost by not analyzing the additional samples.

Samples collected were carried and submitted under Chain-of-Custody to Steve Moody Micro Services LLC, Farmers Branch, Texas for analysis of asbestos using USEPA Method 40 CFR, Chapter 1, Part 763, Subpart F, Appendix A, also known as Polarized Light Microscopy (PLM).

Steve Moody Micro Services LLC is certified by the National Voluntary Laboratory Accreditation Program (NVLAP) and licensed by the Department of State Health Services.

Task Order GSE 013 Page 9 of 26

Building 4732, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama

6. Previous Survey / Plans Review

GSE was not provided with any previously conducted asbestos surveys of the Property. As-built/renovation-site plans and construction drawings were reviewed at the Facilities Department Drawing Room. Review of these documents did not identify building material specifications requiring the use of ACM. However, this does not preclude or prevent the potential use of ACM.

Task Order GSE 013 Page 10 of 26

Building 4732, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama

7. Suspect ACM Materials Not Sampled

During the course of the property visit, GSE performed a preliminary review of interior, accessible areas of the subject building for the presence of suspect asbestos-containing materials (ACMs). This asbestos survey was conducted for overview purposes only; additional suspect materials may exist in concealed locations (behind walls and above ceilings, beneath the floors, within machinery, etc.). Also, not all suspect materials may have been sampled due to the condition or the location of the suspect materials. Destructive sampling of suspect ACMs was not performed. GSE will not be responsible for damaging materials or causing the materials to become friable. The USEPA defines asbestos-containing material as material containing greater than one percent asbestos. This review was not a pre-demolition/renovation survey or for regulatory submittal purposes.

Suspect and/or presumed ACMs were observed within the subject building during the property visit. These suspect and/or presumed ACMs that were not sampled as part of this asbestos survey are listed in the following table.

Sample Description Physical Condition

Friable Yes/No

Type of

ACM

Sample ID

9" X 9" Floor Tile, Located Below Carpet UPS2 NoM

12" X 12" Floor Tile, Located Below Carpet UPS3 NoM

Caulking, On Exterior Wall Joints UPS4 NoM

Grout, On Exterior Wall Masonary UPS5 NoM

Wiring, Fibrous Electrical Cable Covering UPS6 NoM

Fire Doors, Fire Door Insulation UPS7 NoM

Mastic, Mirror Mastic UPS8 NoM

Caulking, Window Glazing UPS10 NoM

Duct Insulation, Duct Vibration Joint UPS11 NoM

Leveling Compound, Below ceramic tile flooring UPS13 NoM

Task Order GSE 013 Page 11 of 26

Building 4732, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama

8. Survey Sampling Results

The results of the Survey are presented in the tables on the following pages. The tables describe the entire suspect Asbestos-Containing Materials (ACMs) identified in the building and list respective sample numbers and laboratory results. Sample numbers presented in the tables correspond to the sample numbers on attached Laboratory Analysis Forms. Also presented in the tables is the estimated quantity and assessed friability for each suspect ACM. For each suspect material identified as ACM, the assessed hazard potential is presented along with GSE’ recommended response action. Hazard potential for each material application is based on the material condition and accessibility to the public and maintenance personnel.

Glossary of Items for the following Table

Type of Asbestos (1) CH = Chrysotile AM = Amosite CR = Crocidolite AN = Anthophyllite TR = Tremolite AC = Actinolite ND = No Asbestos Detected PC = Point Count Method

Type of ACM (2) M = Miscellaneous S = Surfacing TSI = Thermal Systems Insulation

Friability (3) F = Friable NF = Non Friable

Physical Condition (4) U = Good D = Damaged SD = Significantly Damaged

Potential for Disturbance (5) NPD = No Potential for Disturbance PD = Potential for Disturbance PSD = Potential for Significant Disturbance

Assessment Category (6) 1 = Damaged or significantly damaged TSI ACBM, 2 = Damaged friable surfacing ACBM 3 = Significantly damaged friable surfacing ACBM 4 = Damaged or significantly damaged friable miscellaneous ACBM 5 = ACBM with potential for damaged 6 = ACBM potential for significant damage 7 = Any remaining friable ACBM or friable suspected

ACBM

X = not applicable

Unit of Measurement SF = Square Feet

LF = Linear Feet

Sample Location

Sample Analyzed

Yes/No

Estimated Quantity of

ACM

Assessment Category

Physical Condition

Friable Yes/No

Type of

ACM

% and Type of Asbestos Detected

Sample ID Potential For

Distrubance

Homogeneous Area 1

12" x 12" Floor Tile Beige Speckled

Yes M No U XRoom: 168 Grid: F3-1

ND - Floor Tile1 PD

Yes M No U XRoom: 101 Grid: F1-1

ND - Floor Tile2 PD

Yes M No U XRoom: North Stairwell Landing Grid: F1-1

ND - Floor Tile3 PD

Homogeneous Area 2

Mastic Tan Cove Base Mastic

Yes M No U XRoom: 121 Grid: WL1-1

ND - Tan Mastic4 PD

Yes M No U XRoom: 124 Grid: WF1-1

ND - Tan Mastic5 PD

Yes M No U XRoom: 161 Grid: WR1-1

ND - Tan Mastic6 PD

Sample Location

Sample Analyzed

Yes/No

Estimated Quantity of

ACM

Assessment Category

Physical Condition

Friable Yes/No

Type of

ACM

% and Type of Asbestos Detected

Sample ID Potential For

Distrubance

Homogeneous Area 3

Mastic Blue Carpet Yes M No U XRoom: 121 Grid: F1-1

ND - Green Mastic7 PD

Yes M No U XRoom: 161 Grid: F1-1

ND - Green Mastic8 PD

Yes M No U XRoom: 108A Grid: F4-1

ND - Yellow Mastic9 PD

Homogeneous Area 4

2' X 2' Ceiling Tile Fissured

Yes M Yes U XRoom: 167 Grid: C4-4

ND - Acoustic Tile10 PD

Yes M Yes U XRoom: 167 Grid: C3-4

ND - Acoustic Tile11 PD

Yes M Yes U XRoom: 167 Grid: C3-3

ND - Acoustic Tile12 PD

Sample Location

Sample Analyzed

Yes/No

Estimated Quantity of

ACM

Assessment Category

Physical Condition

Friable Yes/No

Type of

ACM

% and Type of Asbestos Detected

Sample ID Potential For

Distrubance

Homogeneous Area 5

Wallboard Drywall System

Yes M No U XRoom: 126 Grid: WR4-3

ND - Drywall Material ND - Joint compound

13 PD

Yes M No U XRoom: 108A Grid: WR4-1

ND - Drywall Material ND - Joint compound

14 PD

Yes M No U XRoom: 110 Grid: WE4-3

ND - Drywall Material ND - Joint compound

15 PD

Homogeneous Area 6

2' X 2' Ceiling Tile Dotted Textured

Yes M Yes U XRoom: 167 Grid: C4-1

ND - Acoustic Tile16 PD

Yes M Yes U XRoom: 167 Grid: C4-2

ND - Acoustic Tile17 PD

Yes M Yes U XRoom: 161 Grid: C2-4

ND - Acoustic Tile18 PD

Sample Location

Sample Analyzed

Yes/No

Estimated Quantity of

ACM

Assessment Category

Physical Condition

Friable Yes/No

Type of

ACM

% and Type of Asbestos Detected

Sample ID Potential For

Distrubance

Homogeneous Area 7

Mastic White Pipe Insulation Mastic

Yes M No U XRoom: 150 Grid: WF1-3

ND - Gray Mastic19 PD

Yes M No U XRoom: 150 Grid: WL1-3

ND - Gray Mastic20 PD

Yes M No U XRoom: 126 Grid: F3-3

ND - Gray Mastic21 PD

Homogeneous Area 8

Pipe Insulation Valve Covering Cloth

Yes 300 LF TSI Yes U 5Room: 150 Grid: WL1-3

ND - Paper/Foil Wrap 5% CH - Thermal Insulation ND - White Mastic

22 PD

No TSI Yes U 5Room: 150 Grid: WL1-3

Not Analyzed Positive Stop

23 PD

No TSI Yes U 5Room: 150 Grid: WL1-3

Not Analyzed Positive Stop

24 PD

Sample Location

Sample Analyzed

Yes/No

Estimated Quantity of

ACM

Assessment Category

Physical Condition

Friable Yes/No

Type of

ACM

% and Type of Asbestos Detected

Sample ID Potential For

Distrubance

Homogeneous Area 9

2' X 2' Ceiling Tile Popcorn Textured

Yes M Yes U XRoom: 121 Grid: C4-4

ND - Acoustic Tile25 PD

Yes M Yes U XRoom: HS107N115 Grid: C1-3

ND - Acoustic Tile26 PD

Yes M Yes U XRoom: 115 Grid: C2-1

ND - Acoustic Tile27 PD

Homogeneous Area 10

Caulking Red Fire Caulking

Yes M No U XRoom: 225 Grid: WE4-4

ND - Caulking28 PD

Yes M No U XRoom: 225 Grid: WE4-4

ND - Caulking29 PD

Yes M No U XRoom: 225 Grid: WF4-1

ND - Caulking30 PD

Sample Location

Sample Analyzed

Yes/No

Estimated Quantity of

ACM

Assessment Category

Physical Condition

Friable Yes/No

Type of

ACM

% and Type of Asbestos Detected

Sample ID Potential For

Distrubance

Homogeneous Area 11

Sink Undercoating Gray Yes M No U XRoom: 223 Grid: F4-2

ND - Sink Undercoating

31 PD

Yes M No U XRoom: 223 Grid: F4-2

ND - Sink Undercoating

32 PD

Yes M No U XRoom: 223 Grid: F4-2

ND - Sink Undercoating

33 PD

Homogeneous Area 12

Pipe Insulation Hard White Pipe Elbows

Yes 100 Elbows TSI Yes U 5Room: 150 Grid: WR2-3

5% CH - Thermal Insulation

34 PD

No TSI Yes U 5Room: 150 Grid: WR2-3

Not Analyzed Positive Stop

35 PD

No TSI Yes U 5Room: 150 Grid: WR2-3

Not Analyzed

36 PD

Sample Location

Sample Analyzed

Yes/No

Estimated Quantity of

ACM

Assessment Category

Physical Condition

Friable Yes/No

Type of

ACM

% and Type of Asbestos Detected

Sample ID Potential For

Distrubance

Homogeneous Area 13

Pipe Insulation Old Hard White Insulation

Yes TSI Yes U XRoom: 150 Grid: WR2-2

ND - Insulation ND - Paper/Foil Wrap ND - White Mastic

37 PD

Yes TSI Yes U XRoom: 150 Grid: WR2-2

ND - Insulation ND - Paper/Foil Wrap ND - White Mastic

38 PD

Yes TSI Yes U XRoom: 150 Grid: WR2-3

ND - Insulation ND - Paper/Foil Wrap ND - White Mastic

39 PD

Homogeneous Area 14

Mastic White Duct Insulation Mastic

Yes M No U XRoom: 126 Grid: C2-2

ND - White Mastic40 PD

Yes M No U XRoom: 126 Grid: C2-1

ND - White Mastic41 PD

Yes M No U XRoom: 128A Grid: C3-4

ND - White Mastic42 PD

Sample Location

Sample Analyzed

Yes/No

Estimated Quantity of

ACM

Assessment Category

Physical Condition

Friable Yes/No

Type of

ACM

% and Type of Asbestos Detected

Sample ID Potential For

Distrubance

Homogeneous Area 15

Mastic Computer Floor Mastic

Yes M No U XRoom: 129F Grid: F1-1

ND - Black Mastic46 PD

Yes M No U XRoom: 129F Grid: F1-2

ND - Black Mastic47 PD

Yes M No U XRoom: 129F Grid: F2-3

ND - Black Mastic48 PD

Homogeneous Area 16

Mastic Stair Tread Mastic

Yes M No U XRoom: HS108N128 Grid: F2-4

ND - Mastic49 PD

Yes M No U XRoom: HE100W150 Grid: F2-1

ND - Mastic50 PD

Yes M No U XRoom: 168 Grid: F4-1

ND - Mastic51 PD

Sample Location

Sample Analyzed

Yes/No

Estimated Quantity of

ACM

Assessment Category

Physical Condition

Friable Yes/No

Type of

ACM

% and Type of Asbestos Detected

Sample ID Potential For

Distrubance

Homogeneous Area 17

Mastic Gray Duct Mastic Yes M No U XRoom: 226 Grid: F4-2

ND - Duct Mastic55 PD

Yes M No U XRoom: 226 Grid: F3-2

ND - Duct Mastic56 PD

Yes M No U XRoom: 226 Grid: F2-2

ND - Duct Mastic57 PD

Homogeneous Area 18

Texture Cementitious Texture on CMU Wall

Yes M No U XRoom: 201 Grid: WR2-1

ND - Paint/Texture58 PD

Yes M No U XRoom: 201 Grid: WR2-2

ND - Paint/Texture59 PD

Yes M No U XRoom: 201 Grid: WR2-3

ND - Paint/Texture60 PD

Sample Location

Sample Analyzed

Yes/No

Estimated Quantity of

ACM

Assessment Category

Physical Condition

Friable Yes/No

Type of

ACM

% and Type of Asbestos Detected

Sample ID Potential For

Distrubance

Homogeneous Area 19

12" x 12" Floor Tile Brown with White Streaks

Yes 325 SF M No U 5Room: 135 Grid: F1-1

3% CH - Floor Tile ND - Yellow Mastic

61 PD

No M No U 5Room: 135 Grid: F1-1

Not Analyzed Positive Stop

62 PD

No M No U 5Room: 135 Grid: F1-1

Not Analyzed Positive Stop

63 PD

Homogeneous Area 20

Other Floor Covering Non Skid Floor Strips

Yes M No U XRoom: 131 Grid: F4-2

ND - Flooring64 PD

Yes M No U XRoom: 131 Grid: F4-2

ND - Flooring65 PD

Yes M No U XRoom: 131 Grid: F4-3

ND - Flooring66 PD

Sample Location

Sample Analyzed

Yes/No

Estimated Quantity of

ACM

Assessment Category

Physical Condition

Friable Yes/No

Type of

ACM

% and Type of Asbestos Detected

Sample ID Potential For

Distrubance

Homogeneous Area 21

Mastic Associated with 12" X 12" Beige Floortile (Sample

Yes M No U XRoom: 168 Grid: F3-1

ND - Black Mastic01A PD

Yes M No U XRoom: 101 Grid: F1-1

ND - Yellow Mastic02A PD

Yes M No U XRoom: North Stair Landing Grid: F1-1

ND - Yellow Mastic03A PD

Homogeneous Area 22

12" x 12" Floor Tile Beige with rown speckles

Yes 6,300 SF M No U 5Room: 131 Grid: F3-4

ND - Floor Tile ND - Yellow Mastic 5% CH - Black Mastic

67 PD

No M No U 5Room: 132 Grid: F1-4

Not Analyzed Positive Stop

68 PD

No M No U 5Room: 136 Grid: F1-1

Not Analyzed

69 PD

Sample Location

Sample Analyzed

Yes/No

Estimated Quantity of

ACM

Assessment Category

Physical Condition

Friable Yes/No

Type of

ACM

% and Type of Asbestos Detected

Sample ID Potential For

Distrubance

Homogeneous Area 23

12" x 12" Floor Tile Brown with brown and white speckles

Yes 1,050 SF M No U 5Room: 129 Grid: F4-1

5% CH - Floor Tile 5% CH - Black Mastic

70 PD

No M No U 5Room: 129A Grid: F2-1

Not Analyzed Positive Stop

71 PD

No M No U 5Room: 129A Grid: F2-1

Not Analyzed Positive Stop

72 PD

Homogeneous Area 24

9" x 9" Floor Tile Dark Brown with Maroon Streaks

Yes 10 SF M No U 5Room: 135 Grid: F1-1

15% CH - Floor Tile 5% CH - Black Mastic

73 PD

No M No U 5Room: 135 Grid: F1-1

Not Analyzed Positive Stop

74 PD

No M No U 5Room: 135 Grid: F1-1

Not Analyzed

75 PD

1. CH = Chrysotile; AM = Amosite; CR = Crocidolite; AN = Anthophyllite; TR = Tremolite; AC = Actinolite; ND = No Asbestos Detected; or PC = Point Count Method

2. M = Miscellaneous; S = Surfacing; or TSI = Thermal Systems Insulation

3. F = Friable or NF = Non Friable

4. U = Good; D = Damaged; or SD = Significantly Damaged

5. NPD = No Potential for Disturbance; PD = Potential for Disturbance; or PSD = Potential for Significant Disturbance

6. 1 = Damaged or significantly damaged TSI ACBM, 2 = Damaged friable surfacing ACBM, 3 = Significantly damaged friable surfacing ACBM, 4 = Damaged or significantly damaged friable miscellaneous ACBM, 5 = ACBM with potential for damage, 6 = ACBM potential for significant damage, 7 = Any remaining friable ACBM or friable suspected ACBM, or X = not applicable

SF = Square Feet LF = Linear Feet

9. Appendices

Appendix A— Laboratory Results and Chain of Custody Appendix B— ACM Sample Location Drawings Appendix C— ACM Location Diagrams Appendix D— Photographs Appendix E— Certificates and Licenses

Appendix A

Laboratory Results

PLM Summary Report NVLAP Lab No. 102056

TDSHS License No. 30-0084

Client :

Project :

Project # :

Identification :

Test Method :

Great Southern Engineering

MSFC Building 4732

GSE-013

Asbestos, Bulk Sample Analysis

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 8/6/2008, forty two (42) bulk material samples were submitted by a representative of Great Southern Engineering for asbestos analysis by PLM/DS.

The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Steve Moody Micro Services, LLC

Lab Job No. :

Report Date :

08B-09300

07/30/2008

08/06/2008

2051 Valley View Lane

Farmers Branch, TX 75234 (Phone 972-241-8460)

1 12" x 12" Floor Tile None Detected - Floor Tile

No Mastic

2 12" x 12" Floor Tile None Detected - Floor Tile

No Mastic

3 12" x 12" Floor Tile None Detected - Floor Tile

No Mastic

4 Cove Base (Tan) None Detected - Tan Mastic

5 Cove Base (Tan) None Detected - Tan Mastic

6 Cove Base (Tan) None Detected - Tan Mastic

7 Carpet Mastic None Detected - Green Mastic

8 Carpet Mastic None Detected - Green Mastic

9 Carpet Mastic None Detected - Yellow Mastic

10 2' x 2' Ceiling Tile None Detected - Acoustic Tile

11 2' x 2' Ceiling Tile None Detected - Acoustic Tile

12 2' x 2' Ceiling Tile None Detected - Acoustic Tile

13 Drywall System None Detected - Drywall Material

None Detected - Joint Compound

14 Drywall System None Detected - Drywall Material

None Detected - Joint Compound

15 Drywall System None Detected - Drywall Material

None Detected - Joint Compound

16 2' x 2' Ceiling Tile None Detected - Acoustic Tile

17 2' x 2' Ceiling Tile None Detected - Acoustic Tile

18 2' x 2' Ceiling Tile None Detected - Acoustic Tile

TDSHS License No. 30-0084

Client :

Project :

Project # :

Identification :

Test Method :

Great Southern Engineering

MSFC Building 4732

GSE-013

Asbestos, Bulk Sample Analysis

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 8/6/2008, forty two (42) bulk material samples were submitted by a representative of Great Southern Engineering for asbestos analysis by PLM/DS.

The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Steve Moody Micro Services, LLC

Lab Job No. :

Report Date :

08B-09300

07/30/2008

08/06/2008

2051 Valley View Lane

Farmers Branch, TX 75234 (Phone 972-241-8460)

19 Pipe Mastic None Detected - Grey Mastic

20 Pipe Mastic None Detected - Grey Mastic

21 Pipe Mastic None Detected - Grey Mastic

22 Valve Insulation None Detected - Paper / Foil Wrap

5% Chrysotile - Thermal Insulation

None Detected - White Mastic

23 Valve Insulation Not Analyzed - Positive Stop

24 Valve Insulation Not Analyzed - Positive Stop

25 2' x 2' Ceiling Tile None Detected - Acoustic Tile

26 2' x 2' Ceiling Tile None Detected - Acoustic Tile

27 2' x 2' Ceiling Tile None Detected - Acoustic Tile

28 Fire Caulking (Red) None Detected - Caulking

29 Fire Caulking (Red) None Detected - Caulking

30 Fire Caulking (Red) None Detected - Caulking

31 Under Sink Coating None Detected - Sink Undercoating

32 Under Sink Coating None Detected - Sink Undercoating

33 Under Sink Coating None Detected - Sink Undercoating

34 Pipe Elbows, Hard Mud 5% Chrysotile - Thermal Insulation

35 Pipe Elbows, Hard Mud Not Analyzed - Positive Stop

36 Pipe Elbows, Hard Mud Not Analyzed - Positive Stop

37 Pipe Insulation None Detected - Insulation

None Detected - Paper / Foil Wrap

None Detected - White Mastic

TDSHS License No. 30-0084

Client :

Project :

Project # :

Identification :

Test Method :

Great Southern Engineering

MSFC Building 4732

GSE-013

Asbestos, Bulk Sample Analysis

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 8/6/2008, forty two (42) bulk material samples were submitted by a representative of Great Southern Engineering for asbestos analysis by PLM/DS.

The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Steve Moody Micro Services, LLC

Lab Job No. :

Report Date :

08B-09300

07/30/2008

08/06/2008

2051 Valley View Lane

Farmers Branch, TX 75234 (Phone 972-241-8460)

38 Pipe Insulation None Detected - Insulation

None Detected - Paper / Foil Wrap

None Detected - White Mastic

39 Pipe Insulation None Detected - Insulation

None Detected - Paper / Foil Wrap

None Detected - White Mastic

40 Duct Mastic None Detected - White Mastic

41 Duct Mastic None Detected - White Mastic

42 Duct Mastic None Detected - White Mastic

Steve MoodyAnalyst(s):

Lab Director : Steve Moody Approved Signatory :

Thank you for choosing Steve Moody Micro Services

These samples were analyzed by layers. Quantification, unless otherwise noted, is performed by calibrated visual estimate. Results may not be reproduced except in full. This test report relates only to the samples tested. These test results do not imply endorsement by NVLAP or any agency of the U.S. Government. Accredited by the

National Voluntary Laboratory Accreditation Program for Bulk Asbestos Fiber Analysis under Lab Code 102056.

Lab Manager : Bruce Crabb Approved Signatory :

Steve Moody Micro Services, LLC PLM Detail Report NVLAP Lab No. 102056

TDSHS License No. 30-0084

Project # : GSE-013

Sample Number Layer Components % Of

Sample

Analysis

Date

% of

Layer Analyst

Supplement to PLM Summary Report 2051 Valley View Lane

Farmers Branch, TX 75234

Client :

Project :

Great Southern Engineering

MSFC Building 4732

Lab Job No. :

Report Date :

08B-09300

08/06/2008

Calcite / Vinyl Binders1 Floor Tile (Tan) 100% 08/06100% SM

1 No Mastic 08/06 SM

Calcite / Vinyl Binders2 Floor Tile (Tan) 100% 08/06100% SM

2 No Mastic 08/06 SM

Calcite / Vinyl Binders3 Floor Tile (Tan) 100% 08/06100% SM

3 No Mastic 08/06 SM

Glue Binders4 Tan Mastic (Tan) 100% 08/06100% SM

Glue Binders5 Tan Mastic (Tan) 100% 08/06100% SM

Glue Binders6 Tan Mastic (Tan) 100% 08/06100% SM

Glue Binders7 Green Mastic (Light Green) 100% 08/06100% SM

Glue Binders8 Green Mastic (Light Green) 100% 08/06100% SM

Glue Binders9 Yellow Mastic (Yellow) 100% 08/06100% SM

Cellulose Fibers10 Acoustic Tile (Off-White) 100% 08/0640% SM

Mineral Wool Fibers10 Acoustic Tile (Off-White) 100% 08/0640% SM

Perlite10 Acoustic Tile (Off-White) 100% 08/0620% SM

Cellulose Fibers11 Acoustic Tile (Off-White) 100% 08/0640% SM

Mineral Wool Fibers11 Acoustic Tile (Off-White) 100% 08/0640% SM

Perlite11 Acoustic Tile (Off-White) 100% 08/0620% SM

Cellulose Fibers12 Acoustic Tile (Off-White) 100% 08/0640% SM

Mineral Wool Fibers12 Acoustic Tile (Off-White) 100% 08/0640% SM

Perlite12 Acoustic Tile (Off-White) 100% 08/0620% SM

Glass Wool Fibers13 Drywall Material (White) 20% 08/062% SM

Gypsum / Binders13 Drywall Material (White) 20% 08/0698% SM

Cellulose Fibers13 DW Paper / Tape (Tan / White) 5% 08/06100% SM

Calcite / Talc / Binders13 Joint Compound (White) 75% 08/06100% SM

Glass Wool Fibers14 Drywall Material (White) 45% 08/062% SM

Gypsum / Binders14 Drywall Material (White) 45% 08/0698% SM

Cellulose Fibers14 DW Paper / Tape (Tan / White) 5% 08/06100% SM

Calcite / Talc / Binders14 Joint Compound (White) 50% 08/06100% SM

Project # : GSE-013

Sample Number Layer Components % Of

Sample

Analysis

Date

% of

Layer Analyst

Supplement to PLM Summary Report 2051 Valley View Lane

Farmers Branch, TX 75234

Client :

Project :

Great Southern Engineering

MSFC Building 4732

Lab Job No. :

Report Date :

08B-09300

08/06/2008

Glass Wool Fibers15 Drywall Material (White) 45% 08/062% SM

Gypsum / Binders15 Drywall Material (White) 45% 08/0698% SM

Cellulose Fibers15 DW Paper / Tape (Tan / White) 5% 08/06100% SM

Calcite / Talc / Binders15 Joint Compound (White) 50% 08/06100% SM

Cellulose Fibers16 Acoustic Tile (Off-White) 100% 08/0640% SM

Mineral Wool Fibers16 Acoustic Tile (Off-White) 100% 08/0640% SM

Perlite16 Acoustic Tile (Off-White) 100% 08/0620% SM

Cellulose Fibers17 Acoustic Tile (Off-White) 100% 08/0640% SM

Mineral Wool Fibers17 Acoustic Tile (Off-White) 100% 08/0640% SM

Perlite17 Acoustic Tile (Off-White) 100% 08/0620% SM

Cellulose Fibers18 Acoustic Tile (Off-White) 100% 08/0640% SM

Mineral Wool Fibers18 Acoustic Tile (Off-White) 100% 08/0640% SM

Perlite18 Acoustic Tile (Off-White) 100% 08/0620% SM

Wollastonite19 Grey Mastic (Grey) 100% 08/065% SM

Polyethylene Fibers19 Grey Mastic (Grey) 100% 08/065% SM

Calcite19 Grey Mastic (Grey) 100% 08/0650% SM

Glue Binders19 Grey Mastic (Grey) 100% 08/0640% SM

Wollastonite20 Grey Mastic (Grey) 100% 08/065% SM

Polyethylene Fibers20 Grey Mastic (Grey) 100% 08/065% SM

Calcite20 Grey Mastic (Grey) 100% 08/0650% SM

Glue Binders20 Grey Mastic (Grey) 100% 08/0640% SM

Wollastonite21 Grey Mastic (Grey) 100% 08/065% SM

Polyethylene Fibers21 Grey Mastic (Grey) 100% 08/065% SM

Calcite21 Grey Mastic (Grey) 100% 08/0650% SM

Glue Binders21 Grey Mastic (Grey) 100% 08/0640% SM

Project # : GSE-013

Sample Number Layer Components % Of

Sample

Analysis

Date

% of

Layer Analyst

Supplement to PLM Summary Report 2051 Valley View Lane

Farmers Branch, TX 75234

Client :

Project :

Great Southern Engineering

MSFC Building 4732

Lab Job No. :

Report Date :

08B-09300

08/06/2008

Cellulose Fibers22 Paper / Foil Wrap (Tan / Silver) 30% 08/0660% SM

Glass Wool Fibers22 Paper / Foil Wrap (Tan / Silver) 30% 08/0620% SM

Metal Foil22 Paper / Foil Wrap (Tan / Silver) 30% 08/0620% SM

Chrysotile22 Thermal Insulation (Light Grey) 15% 08/065% SM

Mineral Wool Fibers22 Thermal Insulation (Light Grey) 15% 08/0620% SM

Binders / Fillers22 Thermal Insulation (Light Grey) 15% 08/0675% SM

Pigment / Binders22 White Mastic (Off-White) 55% 08/06100% SM

23 Not Analyzed - Positive Stop 100% 08/06 SM

24 Not Analyzed - Positive Stop 100% 08/06 SM

Cellulose Fibers25 Acoustic Tile (Off-White) 100% 08/0640% SM

Mineral Wool Fibers25 Acoustic Tile (Off-White) 100% 08/0640% SM

Perlite25 Acoustic Tile (Off-White) 100% 08/0620% SM

Cellulose Fibers26 Acoustic Tile (Off-White) 100% 08/0640% SM

Mineral Wool Fibers26 Acoustic Tile (Off-White) 100% 08/0640% SM

Perlite26 Acoustic Tile (Off-White) 100% 08/0620% SM

Cellulose Fibers27 Acoustic Tile (Off-White) 100% 08/0640% SM

Mineral Wool Fibers27 Acoustic Tile (Off-White) 100% 08/0640% SM

Perlite27 Acoustic Tile (Off-White) 100% 08/0620% SM

Synthetic Fibers28 Caulking (Red) 100% 08/0615% SM

Graphite28 Caulking (Red) 100% 08/065% SM

Binders / Fillers28 Caulking (Red) 100% 08/0680% SM

Synthetic Fibers29 Caulking (Red) 100% 08/0615% SM

Graphite29 Caulking (Red) 100% 08/065% SM

Binders / Fillers29 Caulking (Red) 100% 08/0680% SM

Synthetic Fibers30 Caulking (Red) 100% 08/0615% SM

Graphite30 Caulking (Red) 100% 08/065% SM

Binders / Fillers30 Caulking (Red) 100% 08/0680% SM

Project # : GSE-013

Sample Number Layer Components % Of

Sample

Analysis

Date

% of

Layer Analyst

Supplement to PLM Summary Report 2051 Valley View Lane

Farmers Branch, TX 75234

Client :

Project :

Great Southern Engineering

MSFC Building 4732

Lab Job No. :

Report Date :

08B-09300

08/06/2008

Cellulose Fibers31 Sink Undercoating (Grey) 100% 08/0610% SM

Calcite / Talc31 Sink Undercoating (Grey) 100% 08/0650% SM

Binders / Fillers31 Sink Undercoating (Grey) 100% 08/0640% SM

Cellulose Fibers32 Sink Undercoating (Grey) 100% 08/0610% SM

Calcite / Talc32 Sink Undercoating (Grey) 100% 08/0650% SM

Binders / Fillers32 Sink Undercoating (Grey) 100% 08/0640% SM

Cellulose Fibers33 Sink Undercoating (Grey) 100% 08/0610% SM

Calcite / Talc33 Sink Undercoating (Grey) 100% 08/0650% SM

Binders / Fillers33 Sink Undercoating (Grey) 100% 08/0640% SM

Chrysotile34 Thermal Insulation (Light Grey) 100% 08/065% SM

Mineral Wool Fibers34 Thermal Insulation (Light Grey) 100% 08/0620% SM

Binders / Fillers34 Thermal Insulation (Light Grey) 100% 08/0675% SM

35 Not Analyzed - Positive Stop 100% 08/06 SM

36 Not Analyzed - Positive Stop 100% 08/06 SM

Mineral Wool Fibers37 Insulation (Yellow) 70% 08/0695% SM

Resin Binders37 Insulation (Yellow) 70% 08/065% SM

Cellulose Fibers37 Paper / Foil Wrap (Tan / Silver) 20% 08/0660% SM

Glass Wool Fibers37 Paper / Foil Wrap (Tan / Silver) 20% 08/0620% SM

Metal Foil37 Paper / Foil Wrap (Tan / Silver) 20% 08/0620% SM

Pigment / Binders37 White Mastic (Off-White) 10% 08/06100% SM

Mineral Wool Fibers38 Insulation (Yellow) 80% 08/0695% SM

Resin Binders38 Insulation (Yellow) 80% 08/065% SM

Cellulose Fibers38 Paper / Foil Wrap (Tan / Silver) 10% 08/0660% SM

Glass Wool Fibers38 Paper / Foil Wrap (Tan / Silver) 10% 08/0620% SM

Metal Foil38 Paper / Foil Wrap (Tan / Silver) 10% 08/0620% SM

Pigment / Binders38 White Mastic (Off-White) 10% 08/06100% SM

Project # : GSE-013

Sample Number Layer Components % Of

Sample

Analysis

Date

% of

Layer Analyst

Supplement to PLM Summary Report 2051 Valley View Lane

Farmers Branch, TX 75234

Client :

Project :

Great Southern Engineering

MSFC Building 4732

Lab Job No. :

Report Date :

08B-09300

08/06/2008

Mineral Wool Fibers39 Insulation (Yellow) 70% 08/0695% SM

Resin Binders39 Insulation (Yellow) 70% 08/065% SM

Cellulose Fibers39 Paper / Foil Wrap (Tan / Silver) 15% 08/0660% SM

Glass Wool Fibers39 Paper / Foil Wrap (Tan / Silver) 15% 08/0620% SM

Metal Foil39 Paper / Foil Wrap (Tan / Silver) 15% 08/0620% SM

Pigment / Binders39 White Mastic (Off-White) 15% 08/06100% SM

Synthetic Fibers40 White Mastic (White) 100% 08/062% SM

Calcite40 White Mastic (White) 100% 08/0648% SM

Pigment / Binders40 White Mastic (White) 100% 08/0650% SM

Synthetic Fibers41 White Mastic (White) 100% 08/062% SM

Calcite41 White Mastic (White) 100% 08/0648% SM

Pigment / Binders41 White Mastic (White) 100% 08/0650% SM

Synthetic Fibers42 White Mastic (White) 100% 08/062% SM

Calcite42 White Mastic (White) 100% 08/0648% SM

Pigment / Binders42 White Mastic (White) 100% 08/0650% SM

TDSHS License No. 30-0084

Client :

Project :

Project # :

Identification :

Test Method :

Great Southern Engineering

MSFC Building 4732

GSE-013

Asbestos, Bulk Sample Analysis

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 9/15/2008, eighteen (18) bulk material samples were submitted by a representative of Great Southern Engineering for asbestos analysis by PLM/DS.

The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Steve Moody Micro Services, LLC

Lab Job No. :

Report Date :

08B-10726

09/06/2008

09/17/2008

2051 Valley View Lane

Farmers Branch, TX 75234 (Phone 972-241-8460)

46 Pedestal Mastic None Detected - Black Mastic

47 Pedestal Mastic None Detected - Black Mastic

48 Pedestal Mastic None Detected - Black Mastic

49 Stair Tread Mastic None Detected - Mastic

50 Stair Tread Mastic None Detected - Mastic

51 Stair Tread Mastic None Detected - Mastic

55 Duct Mastic None Detected - Duct Mastic

56 Duct Mastic None Detected - Duct Mastic

57 Duct Mastic None Detected - Duct Mastic

58 Wall Texture Material None Detected - Paint / Texture

59 Wall Texture Material None Detected - Paint / Texture

60 Wall Texture Material None Detected - Paint / Texture

61 12" x 12" Floor Tile 3% Chrysotile - Floor Tile

None Detected - Yellow Mastic

62 12" x 12" Floor Tile Not Analyzed - Positive Stop

63 12" x 12" Floor Tile Not Analyzed - Positive Stop

64 Non-skid Floor None Detected - Flooring

65 Non-skid Floor None Detected - Flooring

66 Non-skid Floor None Detected - Flooring

TDSHS License No. 30-0084

Client :

Project :

Project # :

Identification :

Test Method :

Great Southern Engineering

MSFC Building 4732

GSE-013

Asbestos, Bulk Sample Analysis

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 9/15/2008, eighteen (18) bulk material samples were submitted by a representative of Great Southern Engineering for asbestos analysis by PLM/DS.

The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Steve Moody Micro Services, LLC

Lab Job No. :

Report Date :

08B-10726

09/06/2008

09/17/2008

2051 Valley View Lane

Farmers Branch, TX 75234 (Phone 972-241-8460)

Shaun WilkersonAnalyst(s):

Lab Director : Steve Moody Approved Signatory :

Thank you for choosing Steve Moody Micro Services

These samples were analyzed by layers. Quantification, unless otherwise noted, is performed by calibrated visual estimate. Results may not be reproduced except in full. This test report relates only to the samples tested.