Bldg_4464_Asbestos_Survey_Report_Final.pdf

PDF 6 MB Posted

Attached to
Central Steam Distribution Replacement Phase 2 Federal contract opportunity
Solicitation number
80MSFC18B0003
Issued by
National Aeronautics and Space Administration Marshall Space Flight Center

About this file

Bldg 4464 Asbestos Survey Report Final

View the file

Other files for this federal contract opportunity

Other files attached to Central Steam Distribution Replacement Phase 2, newest first.
File Type Posted
Abstract_of_Bids,_80MSFC18B0003.pdf PDF
IFB_80MSFC18B0003,_Posted_Copy,_Aug_9,_2018_REVISED_BLOCK_13.pdf PDF
IFB_80MSFC18B0003,_Amendment_4,_REVISED_BLOCKS_11_&_13.pdf PDF
IFB_80MSFC18B0003,_Amendment_4.pdf PDF
IFB_80MSFC18B0003,_Posted_Copy,_Aug_9,_2018.pdf PDF
33_16_15_-_Thermal_Energy_Storage_Tank_Specification,_Amendment_4.pdf PDF
Revised_Plans,_FAC-5071,_80MSFC18B0003.pdf PDF
IFB_80MSFC18B0003,_Amendment_3.pdf PDF
Army_and_NASA_Site_Access_Control_Boundaries_Map.pdf PDF
Bid_Instructions_for_IFB_80MSFC18B0003,_Amendment_3.pdf PDF
Attendees_at_Site_Visit,_June_20,_2018,_IFB_80MSFC18B0003.pdf PDF
IFB_80MSFC18B0003,_Amendment_2.pdf PDF
IFB_80MSFC18B0003,_Posted_Copy,_July_20,_2018.pdf PDF
Bldg_4704_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4483_Asbestos_Survey_Report_Final.pdf PDF
IFB_80MSFC18B0003,_Posted_Copy,_June_26,_2018.pdf PDF
80MSFC18B003,_Amendment_1.pdf PDF
Bldg_4711_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4493_Asbestos_Survey_Report_Final.pdf PDF
Specifications_FAC-M5066,_80MSFC18B0003.pdf PDF
Plans,_FAC-5066,_80MSFC18B0003.pdf PDF
Bldg_4776_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4727_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4312_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4723_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4732_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4491_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4306_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4733_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4747_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4777_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4705_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4738_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4485_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4702_Asbestos_Survey_Report_Final.pdf PDF
Bldg_4715_Asbestos_Survey_Report_Final.pdf PDF
Specifications_FAC-M5071,_80MSFC18B0003.pdf PDF
Plans,_80MSFC18B0003.pdf PDF
IFB_80MSFC18B0003.pdf PDF
Bid_Instructions_for_IFB_80MSFC18B0003.pdf PDF
Show all 40

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

General Asbestos Survey for Asbestos-Containing Materials

Prepared for:

Marshall Space Flight Center, AL

Building 4464 Marshall Space Flight Center

GSE - 017

April 30, 2009

Prepared by

Great Southern Engineering, Inc.

3795 Gordon Terry Parkway

Trinity, Alabama 35673

TABLE OF CONTENTS

1. Introduction

2. Summary

2.1. Suspect ACMs

2.2. Recommendations

3. Survey Scope

4. Limitations

5. Survey and Sample Collection Procedure

6. Previous Survey / Plans Review

7. Suspect ACM Materials Not Sampled

8. Survey Sampling Results

9. Appendices

Task Order GSE 017 Page 1 of 26

GENERAL ASBESTOS SURVEY OF

Building 4464, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama

1. Introduction

In accordance with GSE Task Order No.GSE-017 dated August 15, 2008, Great Southern Engineering, Inc. (GSE) has performed an asbestos survey of Building 4464 located at George C.

Marshall Space Flight Center, Marshall Space Flight Center, Alabama. The 12,507 square feet building was identified to have been originally constructed in 1994. A total of 39 samples were collected from the building.

The objective of the Asbestos Survey is to determine the location and quantity of asbestos-containing materials at the Property building.

GSE’s Scope of Work included:

Visual inspection and identification of suspect asbestos-containing materials (ACMs) in the Property building and collected a representative number of samples for analysis.

As part of this asbestos survey, GSE personnel collected samples of all suspect friable and suspect damaged non-friable building materials at the Property. The remaining suspect non-friable materials were not be sampled as part of this asbestos survey

Estimated quantities and locations of ACM.

Assessed the condition of the ACM identified.

Assigned a hazard rating to each type of ACM.

This report has been prepared for the use of George C. Marshall Space Flight Center. Our investigation was performed using the degree of care and skill ordinarily exercised under similar circumstances by professional consultants practicing in this or similar localities. No other warranty or guarantee, expressed or implied, is made as to the conclusions included in this report.

Task Order GSE 017 Page 2 of 26

Building 4464, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama

The GSE, Inc. did not perform destructive sampling procedures at the site; therefore, regardless of the thoroughness of this survey, it is possible that suspected asbestos-containing materials (ACMs) might exist in the building beneath the floors, behind walls, within pipe chases, or in other inaccessible locations. If, during renovation or demolition activities, materials not addressed in this survey are discovered, these materials should be sampled and analyzed for asbestos content prior to disturbance.

Surveyed by:

Jeff R Smith

University of Alabama Safe State Program Accredited Inspector/Management Planner

Accreditation #APL0408S7033

Written by:

Manju Ramasamudra

University of Alabama Safe State Program Accredited Inspector/Management Planner

Accreditation #APL0308R5089

Task Order GSE 017 Page 3 of 26

Building 4464, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama

2. Summary

GSE performed an Asbestos Survey and Hazard Assessment at Building 4464 in Marshall Space Flight Center, Alabama on January 18, 2009. Sample collection was completed by licensed personnel

– Jeff R Smith. The following report summarizes the independent conclusions representing GSE’ best professional judgment based on information and data available to us during the course of this survey. Factual information regarding operations, conditions, and tests data provided by the client, owner or their representative has been assumed to be correct and complete. Additionally, the conclusions presented are based on the conditions that existed on the date(s) of the assessment.

The 12,507 square feet building was identified to have been originally constructed in 1994. A total of 39 samples were collected from the building. No homogeneous materials were identified as asbestos-containing materials.

Task Order GSE 017 Page 4 of 26

Building 4464, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama

2.1. Suspect ACMs

The following information is included for informational purposes:

A. The following suspect asbestos-containing materials were not sampled as part of this scope of work:

Suspect fibrous electrical cable covering (danger of electrocution) were not sampled.

These materials are not subject to regulation under NESHAP for demolition and renovation as long as they are in good condition and are not subject to sanding, grinding, cutting, or abrading.

Since ordinary demolition activities do not include sanding, grinding, cutting, and abrading, these materials may remain in place during building demolition, as long as they remain in good condition and are not friable.

If the material is in poor condition and is friable at the time of demolition or renovation, or if it will be subjected to sanding, grinding, cutting, or abrading, it should first be removed by a licensed asbestos removal contractor and disposed of as asbestos-containing waste.

When removing asphalt-roofing products, the material should be removed using a method that does not subject the material to sanding, cutting, grinding, or abrading (hand tools).

Asbestos-containing roofing may be disposed of as construction debris.

2.2. Recommendations

The following additional actions are recommended:

No further actions are recommended at this time.

Task Order GSE 017 Page 5 of 26

Building 4464, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama

3. Survey Scope

This survey was conducted for the purpose of identifying asbestos-containing materials (ACM) throughout the building and to conduct a hazard assessment on existing ACM. The survey was non-destructive in nature and limited only to those areas that were readily accessible.

Specific areas to which access was limited by occupant request, unavailability of keys, or by site conditions included the following:

Behind the walls

Beneath the floors

Any suspect ACM not sampled as part of the assessment and if any additional suspect materials were to be identified behind walls and beneath the floors should be sampled prior to repair, renovation, or demolition activities.

Task Order GSE 017 Page 6 of 26

Building 4464, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama

4. Limitations

GSE did not attempt to disassemble mechanical equipment, open pipe chases or assess materials within wall voids. Regardless of the thoroughness of a survey, the possibility exists that some areas containing asbestos were not identified, inaccessible or different from those at specific locations. The findings and opinions presented are relative to the dates of our site work and should not be relied upon to represent conditions at substantially later dates due to changes in the condition ACM may change over time, renovations and repairs.

This report is for the exclusive use of the client and its agents and use by any unauthorized parties in whole or in part, except as directed by legal jurisdiction, is at the sole risk of the user.

If this assessment includes reliance on work products and/or documents prepared by others, GSE has no responsibility for the accuracy of information contained therein.

Although this assessment has attempted to identify the presence or absence of ACM, potential sources of ACM may have escaped detection due to: (1) the scope of this assessment, (2) the inaccuracy of records, interviews, work products or documents made available to GSE for this report, (3) the presence of undetected or unreported renovations and repairs, (4) inaccessible areas, and/or (5) deliberate concealment of detrimental information.

Estimates presented in this report are based upon observations during the survey and owner-provided information. These reasonable estimates may be affected by unanticipated conditions potentially present in inaccessible or un-surveyed areas. GSE does not warrant or guarantee the quantity estimates. The use of such estimates shall be at the user's own risk and shall constitute a release and agreement to defend and indemnify GSE from and against any liability. If questions arise during the planning for renovation, demolition, or other construction activities, GSE should be notified to permit review of the data and present recommendations.

Interior of the following rooms were inaccessible during our Asbestos Survey on January 18, 2009: None.

Task Order GSE 017 Page 7 of 26

Building 4464, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama

5. Survey and Sample Collection Procedure

Based on United States Environmental Protection Agency (USEPA) guidance documents, GSE considered all material applications identified during the visual assessment were suspect ACM and sampled as described below.

Bulk samples were collected of any materials, which were suspected of containing asbestos with the exception of fire doors. Fire doors were not sampled because the damage caused by sampling would render these materials friable and may also void the fire rating. Since these materials were not sampled, they should be assumed to be asbestos containing, unless sampled and proven otherwise. Sampling of these assumed ACMs should be performed prior to any renovation or other activity that may cause a material disturbance.

Samples of the remaining suspect ACM were taken in accordance with USEPA recommendations.

The number and location of samples collected was based on the type of material, the manner of application, and the homogeneity of the ACM (similarity of color, texture, and type). Each sample was collected and placed into an individual sample container. The sample location was noted on the field survey form and assigned an individual identification number. This number was affixed to the sample container as the sample was collected. The survey form was also used to note the material type and general condition of the material. During the inspection, each suspect material's accessibility, location, and friability were recorded. This information was used to assess the potential hazard of the ACM and to prioritize response action recommendations.

The USEPA defines asbestos-containing materials (ACM) as those that contain greater than one percent asbestos. Friable materials are defined as those that can be crumbled or reduced to powder by hand pressure.

GSE utilized the “positive-stop” method of sample analysis. In this method, analysis is stopped on a group of samples once the first positive (e.g., greater than 1% asbestos) sample is analyzed.

According to the USEPA, if one sample of a homogenous material is identified to be asbestos containing, the entire material must be considered asbestos containing. By using the positive-stop method, GSE reduces the Client’s laboratory analysis cost by not analyzing the additional samples.

Samples collected were carried and submitted under Chain-of-Custody to Steve Moody Micro Services LLC, Farmers Branch, Texas for analysis of asbestos using USEPA Method 40 CFR, Chapter 1, Part 763, Subpart F, Appendix A, also known as Polarized Light Microscopy (PLM).

Steve Moody Micro Services LLC is certified by the National Voluntary Laboratory Accreditation Program (NVLAP) and licensed by the Department of State Health Services.

Task Order GSE 017 Page 8 of 26

Building 4464, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama

6. Previous Survey / Plans Review

GSE was not provided with any previously conducted asbestos surveys of the Property. As-built/renovation-site plans and construction drawings were reviewed at the Facilities Department Drawing Room. Review of these documents did not identify building material specifications requiring the use of ACM. However, this does not preclude or prevent the potential use of ACM.

Task Order GSE 017 Page 9 of 26

Building 4464, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama

7. Suspect ACM Materials Not Sampled

During the course of the property visit, GSE performed a preliminary review of interior, accessible areas of the subject building for the presence of suspect asbestos-containing materials (ACMs). This asbestos survey was conducted for overview purposes only; additional suspect materials may exist in concealed locations (behind walls and above ceilings, beneath the floors, within machinery, etc.). Also, not all suspect materials may have been sampled due to the condition or the location of the suspect materials. Destructive sampling of suspect ACMs was not performed. GSE will not be responsible for damaging materials or causing the materials to become friable. The USEPA defines asbestos-containing material as material containing greater than one percent asbestos. This review was not a pre-demolition/renovation survey or for regulatory submittal purposes.

Suspect and/or presumed ACMs were observed within the subject building during the property visit. These suspect and/or presumed ACMs that were not sampled as part of this asbestos survey are listed in the following table.

Sample Description Physical Condition

Friable Yes/No

Type of

ACM

Sample ID

4464Building Number

Caulking, On Exterior Wall Joints UPS4 NoM

Grout, On Exterior Wall Masonry UPS5 NoM

Wiring, Fibrous Electrical Cable Covering UPS6 NoM

Fire Doors, Fire Door Insulation UPS7 NoM

Table Tops, Lab Table Tops UPS11 NoM

Task Order GSE 017 Page 10 of 26

Building 4464, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama

8. Survey Sampling Results

The results of the Survey are presented in the tables on the following pages. The tables describe the entire suspect Asbestos-Containing Materials (ACMs) identified in the building and list respective sample numbers and laboratory results. Sample numbers presented in the tables correspond to the sample numbers on attached Laboratory Analysis Forms. Also presented in the tables is the estimated quantity and assessed friability for each suspect ACM. For each suspect material identified as ACM, the assessed hazard potential is presented along with GSE’ recommended response action. Hazard potential for each material application is based on the material condition and accessibility to the public and maintenance personnel.

Glossary of Items for the following Table

Type of Asbestos (1) CH = Chrysotile AM = Amosite CR = Crocidolite AN = Anthophyllite TR = Tremolite AC = Actinolite ND = No Asbestos Detected PC = Point Count Method

Type of ACM (2) M = Miscellaneous S = Surfacing TSI = Thermal Systems Insulation

Friability (3) F = Friable NF = Non Friable

Physical Condition (4) U = Good D = Damaged SD = Significantly Damaged

Potential for Disturbance (5) NPD = No Potential for Disturbance PD = Potential for Disturbance PSD = Potential for Significant Disturbance

Assessment Category (6) 1 = Damaged or significantly damaged TSI ACBM, 2 = Damaged friable surfacing ACBM 3 = Significantly damaged friable surfacing ACBM 4 = Damaged or significantly damaged friable miscellaneous ACBM 5 = ACBM with potential for damaged 6 = ACBM potential for significant damage 7 = Any remaining friable ACBM or friable suspected

ACBM

X = not applicable

Unit of Measurement SF = Square Feet

LF = Linear Feet

Sample Description

Sample Location

Sample Analyzed

Yes/No

Estimated Quantity of

ACM

Assessment Category

Physical Condition

Friable Yes/No

Type of

ACM

% and Type of Asbestos Detected

Sample ID Potential For

Distrubance

4464Building Number

Homogeneous Area 1

Wallboard with Associated Texture

Yes M No U XRoom: 130 Grid: WR4-2

ND - Drywall Material ND - Texture

1 PD

Yes M No U XRoom: HE100W102 Grid: WL4-4

ND - Drywall Material ND - Texture

2 PD

Yes M No U XRoom: 111C Grid: WE1-1

ND - Drywall Material ND - Texture

3 PD

Homogeneous Area 2

Cove Base Brown and Associated Mastic

Yes M No U XRoom: 133 Grid: WE1-1

ND - Cove Base ND - Cream Mastic

4 PD

Yes M No U XRoom: 105 Grid: WE1-2

ND - Cove Base ND - Cream Mastic

5 PD

Yes M No U XRoom: 111C Grid: WE1-1

ND - Cove Base ND - Cream Mastic

6 PD

Sample Location

Sample Analyzed

Yes/No

Estimated Quantity of

ACM

Assessment Category

Physical Condition

Friable Yes/No

Type of

ACM

% and Type of Asbestos Detected

Sample ID Potential For

Distrubance

4464Building Number

Homogeneous Area 3

Mastic Associated with Blue Green Carpet

Yes M No U XRoom: 111 Grid: F3-2

ND - Yellow Mastic7 PD

Yes M No U XRoom: 105 Grid: F2-4

ND - Yellow Mastic8 PD

Yes M No U XRoom: 141 Grid: F1-1

ND - Yellow Mastic ND - Blue Mastic

9 PD

Homogeneous Area 4

2' X 2' Ceiling Tile Textured with Pinholes

Yes M Yes U XRoom: HE100W102 Grid: C1-4

ND - Acoustic Tile10 PD

Yes M Yes U XRoom: 105 Grid: C3-2

ND - Acoustic Tile11 PD

Yes M Yes U XRoom: 111 Grid: C2-2

ND - Acoustic Tile12 PD

Sample Location

Sample Analyzed

Yes/No

Estimated Quantity of

ACM

Assessment Category

Physical Condition

Friable Yes/No

Type of

ACM

% and Type of Asbestos Detected

Sample ID Potential For

Distrubance

4464Building Number

Homogeneous Area 5

12" x 12" Floor Tile Beige with Tan and Brown Speckles

Yes M No U XRoom: Stairwell Grid: F4-1

ND - Floor Tile ND - Black Mastic

13 PD

Yes M No U XRoom: 133 Grid: F1-1

ND - Floor Tile ND - Yellow Mastic

14 PD

Yes M No U XRoom: 130 Grid: F4-4

ND - Floor Tile ND - Yellow Mastic

15 PD

Homogeneous Area 6

Pipe Insulation with White Mastic

Yes TSI Yes U XRoom: 200 Grid: C1-3

ND - Insulation ND - Paper/ Foil Wrap ND - White Mastic

16 PD

Yes TSI Yes U XRoom: 200 Grid: C1-3

ND - Insulation ND - Paper/ Foil Wrap ND - White Mastic

17 PD

Yes TSI Yes U XRoom: 150 Grid: C1-3

ND - Insulation ND - Paper/ Foil Wrap ND - White Mastic

18 PD

Sample Location

Sample Analyzed

Yes/No

Estimated Quantity of

ACM

Assessment Category

Physical Condition

Friable Yes/No

Type of

ACM

% and Type of Asbestos Detected

Sample ID Potential For

Distrubance

4464Building Number

Homogeneous Area 7

Mastic Associated with Multicolored Carpet

Yes M No U XRoom: 109 Grid: F3-1

ND - Clear Mastic19 PD

Yes M No U XRoom: 109 Grid: F2-3

ND - Clear Mastic20 PD

Yes M No U XRoom: 110 Grid: F3-2

ND - Clear Mastic21 PD

Homogeneous Area 8

Other Floor Covering Non Skid Pads and Mastic

Yes M No U XRoom: 100A Grid: F2-4

ND - Pad ND - Yellow Mastic

22 PD

Yes M No U XRoom: 100A Grid: F4-1

ND - Pad ND - Yellow Mastic

23 PD

Yes M No U XRoom: 130A Grid: F2-4

ND - Pad ND - Yellow Mastic

24 PD

Sample Location

Sample Analyzed

Yes/No

Estimated Quantity of

ACM

Assessment Category

Physical Condition

Friable Yes/No

Type of

ACM

% and Type of Asbestos Detected

Sample ID Potential For

Distrubance

4464Building Number

Homogeneous Area 9

2' X 2' Ceiling Tile Textured with Small Fissures

Yes M Yes U XRoom: 130 Grid: C4-1

ND - Acoustic Tile25 PD

Yes M Yes U XRoom: 137 Grid: C2-2

ND - Acoustic Tile26 PD

Yes M Yes U XRoom: 130 Grid: C3-4

ND - Acoustic Tile27 PD

Homogeneous Area 10

Cove Base Black and Associated Mastic

Yes M No U XRoom: 130 Grid: WL1-2

ND - Cove Base ND - Cream Mastic

28 PD

Yes M No U XRoom: 131 Grid: WE1-1

ND - Cove Base ND - Cream Mastic

29 PD

Yes M No U XRoom: 102 Grid: WE1-3

ND - Cove Base ND - Cream Mastic

30 PD

Sample Location

Sample Analyzed

Yes/No

Estimated Quantity of

ACM

Assessment Category

Physical Condition

Friable Yes/No

Type of

ACM

% and Type of Asbestos Detected

Sample ID Potential For

Distrubance

4464Building Number

Homogeneous Area 11

Mastic White on HVAC Ducts

Yes M No U XRoom: 150 Grid: C4-2

ND - Mastic31 PD

Yes M No U XRoom: 150 Grid: C3-2

ND - Mastic32 PD

Yes M No U XRoom: 150 Grid: C3-3

ND - Mastic33 PD

Homogeneous Area 12

Insulation Canvas Covered Tank with White Mastic

Yes TSI Yes SD XRoom: 150 Grid: C1-4

ND - Insulation ND - Paper/ Foil Wrap ND - White Mastic

34 PSD

Yes TSI Yes SD XRoom: 150 Grid: C2-4

ND - Insulation ND - Paper/ Foil Wrap ND - White Mastic

35 PSD

Yes TSI Yes SD XRoom: 150 Grid: C2-4

ND - Insulation ND - Paper/ Foil Wrap ND - White Mastic

36 PSD

Sample Location

Sample Analyzed

Yes/No

Estimated Quantity of

ACM

Assessment Category

Physical Condition

Friable Yes/No

Type of

ACM

% and Type of Asbestos Detected

Sample ID Potential For

Distrubance

4464Building Number

Homogeneous Area 13

Insulation Pipe Insulation with Gray Mastic

Yes TSI Yes U XRoom: 120 Grid: C2-2

ND - Insulation ND - Paper/ Foil Wrap ND - Gray Mastic

37 PD

Yes TSI Yes U XRoom: 120 Grid: C1-2

ND - Insulation ND - Paper/ Foil Wrap ND - Gray Mastic

38 PD

Yes TSI Yes U XRoom: 120 Grid: C3-4

ND - Insulation ND - Paper/ Foil Wrap ND - Gray Mastic

39 PD

1. CH = Chrysotile; AM = Amosite; CR = Crocidolite; AN = Anthophyllite; TR = Tremolite; AC = Actinolite; ND = No Asbestos Detected; or PC = Point Count Method

2. M = Miscellaneous; S = Surfacing; or TSI = Thermal Systems Insulation

3. F = Friable or NF = Non Friable

4. U = Good; D = Damaged; or SD = Significantly Damaged

5. NPD = No Potential for Disturbance; PD = Potential for Disturbance; or PSD = Potential for Significant Disturbance

6. 1 = Damaged or significantly damaged TSI ACBM, 2 = Damaged friable surfacing ACBM, 3 = Significantly damaged friable surfacing ACBM, 4 = Damaged or significantly damaged friable miscellaneous ACBM, 5 = ACBM with potential for damage, 6 = ACBM potential for significant damage, 7 = Any remaining friable ACBM or friable suspected ACBM, or X = not applicable

SF = Square Feet LF = Linear Feet

9. Appendices

Appendix A— Laboratory Results and Chain of Custody Appendix B— ACM Sample Location Drawings Appendix C— ACM Location Diagrams Appendix D— Photographs Appendix E— Certificates and Licenses

Appendix A

Laboratory Results

PLM Summary Report NVLAP Lab No. 102056

TDSHS License No. 30-0084

Client :

Project :

Project # :

Identification :

Test Method :

Great Southern Engineering

MSFC, Building 4464

GSE-017

Asbestos, Bulk Sample Analysis

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 1/28/2009, thirty nine (39) bulk material samples were submitted by a representative of Great Southern Engineering for asbestos analysis by PLM/DS.

The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Steve Moody Micro Services, LLC

Lab Job No. :

Report Date :

09B-00880

01/18/2009

01/29/2009

2051 Valley View Lane

Farmers Branch, TX 75234 (Phone 972-241-8460)

01 Wall System None Detected - Drywall Material

None Detected - Texture

02 Wall System None Detected - Drywall Material

None Detected - Texture

03 Wall System None Detected - Drywall Material

None Detected - Texture

04 Cove Base (Brown) and Mastic None Detected - Cove Base

None Detected - Cream Mastic

05 Cove Base (Brown) and Mastic None Detected - Cove Base

None Detected - Cream Mastic

06 Cove Base (Brown) and Mastic None Detected - Cove Base

None Detected - Cream Mastic

07 Mastic, Blue-Green Carpet None Detected - Yellow Mastic

08 Mastic, Blue-Green Carpet None Detected - Yellow Mastic

09 Mastic, Blue-Green Carpet None Detected - Yellow Mastic

None Detected - Blue Mastic

10 2' x 2' Ceiling Tile (Textured with Pinholes) None Detected - Acoustic Tile

11 2' x 2' Ceiling Tile (Textured with Pinholes) None Detected - Acoustic Tile

12 2' x 2' Ceiling Tile (Textured with Pinholes) None Detected - Acoustic Tile

13 12" x 12" Floor Tile (Beige with Tan and Brown Smudges) and Mastic

None Detected - Floor Tile

None Detected - Black Mastic

14 12" x 12" Floor Tile (Beige with Tan and Brown Smudges) and Mastic

None Detected - Floor Tile

None Detected - Yellow Mastic

15 12" x 12" Floor Tile (Beige with Tan and Brown Smudges) and Mastic

None Detected - Floor Tile

None Detected - Yellow Mastic

TDSHS License No. 30-0084

Client :

Project :

Project # :

Identification :

Test Method :

Great Southern Engineering

MSFC, Building 4464

GSE-017

Asbestos, Bulk Sample Analysis

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 1/28/2009, thirty nine (39) bulk material samples were submitted by a representative of Great Southern Engineering for asbestos analysis by PLM/DS.

The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Steve Moody Micro Services, LLC

Lab Job No. :

Report Date :

09B-00880

01/18/2009

01/29/2009

2051 Valley View Lane

Farmers Branch, TX 75234 (Phone 972-241-8460)

16 Mastic (White) with Pipe Insulation None Detected - Insulation

None Detected - Paper / Foil Wrap

None Detected - White Mastic

17 Mastic (White) with Pipe Insulation None Detected - Insulation

None Detected - Paper / Foil Wrap

None Detected - White Mastic

18 Mastic (White) with Pipe Insulation None Detected - Insulation

None Detected - Paper / Foil Wrap

None Detected - White Mastic

19 Mastic, Multicolored Carpet None Detected - Clear Mastic

20 Mastic, Multicolored Carpet None Detected - Clear Mastic

21 Mastic, Multicolored Carpet None Detected - Clear Mastic

22 Non-skid Pads and Mastic None Detected - Pad

None Detected - Yellow Mastic

23 Non-skid Pads and Mastic None Detected - Pad

None Detected - Yellow Mastic

24 Non-skid Pads and Mastic None Detected - Pad

None Detected - Yellow Mastic

25 2' x 2' Ceiling Tiles (Textured with Small Fissures) None Detected - Acoustic Tile

26 2' x 2' Ceiling Tiles (Textured with Small Fissures) None Detected - Acoustic Tile

27 2' x 2' Ceiling Tiles (Textured with Small Fissures) None Detected - Acoustic Tile

28 Cove Base (Black) and Mastic None Detected - Cove Base

None Detected - Cream Mastic

29 Cove Base (Black) and Mastic None Detected - Cove Base

None Detected - Cream Mastic

30 Cove Base (Black) and Mastic None Detected - Cove Base

None Detected - Cream Mastic

TDSHS License No. 30-0084

Client :

Project :

Project # :

Identification :

Test Method :

Great Southern Engineering

MSFC, Building 4464

GSE-017

Asbestos, Bulk Sample Analysis

Polarized Light Microscopy / Dispersion Staining (PLM/DS)

EPA Method 600 / R-93 / 116

Sample Number Client Sample Description / Location Asbestos Content

Sample Date :

On 1/28/2009, thirty nine (39) bulk material samples were submitted by a representative of Great Southern Engineering for asbestos analysis by PLM/DS.

The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:

Steve Moody Micro Services, LLC

Lab Job No. :

Report Date :

09B-00880

01/18/2009

01/29/2009

2051 Valley View Lane

Farmers Branch, TX 75234 (Phone 972-241-8460)

31 Mastic (White) on HVAC Ducts None Detected - Mastic

32 Mastic (White) on HVAC Ducts None Detected - Mastic

33 Mastic (White) on HVAC Ducts None Detected - Mastic

34 Mastic (White) with Canvas Covered Tank and Insulation None Detected - Insulation

None Detected - Paper / Foil Wrap

None Detected - White Mastic

35 Mastic (White) with Canvas Covered Tank and Insulation None Detected - Insulation

None Detected - Paper / Foil Wrap

None Detected - White Mastic

36 Mastic (White) with Canvas Covered Tank and Insulation None Detected - Insulation

None Detected - Paper / Foil Wrap

None Detected - White Mastic

37 Mastic (Gray) with Pipe Insulation None Detected - Insulation

None Detected - Paper / Foil Wrap

None Detected - Grey Mastic

38 Mastic (Gray) with Pipe Insulation None Detected - Insulation

None Detected - Paper / Foil Wrap

None Detected - Grey Mastic

39 Mastic (Gray) with Pipe Insulation None Detected - Insulation

None Detected - Paper / Foil Wrap

None Detected - Grey Mastic

Debra O'SullivanAnalyst(s):

Lab Director : Steve Moody Approved Signatory :

Thank you for choosing Steve Moody Micro Services

These samples were analyzed by layers. Quantification, unless otherwise noted, is performed by calibrated visual estimate. Results may not be reproduced except in full. This test report relates only to the samples tested. These test results do not imply endorsement by NVLAP or any agency of the U.S. Government. Accredited by the

National Voluntary Laboratory Accreditation Program for Bulk Asbestos Fiber Analysis under Lab Code 102056.

Lab Manager : Bruce Crabb Approved Signatory :

Steve Moody Micro Services, LLC PLM Detail Report NVLAP Lab No. 102056

TDSHS License No. 30-0084

Project # : GSE-017

Sample Number Layer Components % Of

Sample

Analysis

Date

% of

Layer Analyst

Supplement to PLM Summary Report 2051 Valley View Lane

Farmers Branch, TX 75234

Client :

Project :

Great Southern Engineering

MSFC, Building 4464

Lab Job No. :

Report Date :

09B-00880

01/29/2009

Glass Wool Fibers01 Drywall Material (Off-White) 85% 01/292% DO

Cellulose Fibers01 Drywall Material (Off-White) 85% 01/291% DO

Gypsum / Binders01 Drywall Material (Off-White) 85% 01/2997% DO

Cellulose Fibers01 DW Paper Facing (Tan) 5% 01/29100% DO

Calcite / Talc / Binders01 Texture (White) 10% 01/29100% DO

Cellulose Fibers02 Drywall Material (Pink) 85% 01/295% DO

Gypsum / Binders02 Drywall Material (Pink) 85% 01/2995% DO

Cellulose Fibers02 DW Paper Facing (Tan) 5% 01/29100% DO

Calcite / Talc / Binders02 Texture (White) 10% 01/29100% DO

Glass Wool Fibers03 Drywall Material (White) 93% 01/292% DO

Cellulose Fibers03 Drywall Material (White) 93% 01/291% DO

Gypsum / Binders03 Drywall Material (White) 93% 01/2997% DO

Cellulose Fibers03 DW Paper Facing (Tan) 5% 01/29100% DO

Calcite / Talc / Binders03 Texture (White) 2% 01/29100% DO

Calcite / Vinyl Binders04 Cove Base (Tan) 95% 01/29100% DO

Calcite04 Cream Mastic (Cream) 5% 01/2950% DO

Glue Binders04 Cream Mastic (Cream) 5% 01/2950% DO

Calcite / Vinyl Binders05 Cove Base (Brown) 95% 01/29100% DO

Calcite05 Cream Mastic (Cream) 5% 01/2950% DO

Glue Binders05 Cream Mastic (Cream) 5% 01/2950% DO

Calcite / Vinyl Binders06 Cove Base (Brown) 95% 01/29100% DO

Calcite06 Cream Mastic (Cream) 5% 01/2950% DO

Glue Binders06 Cream Mastic (Cream) 5% 01/2950% DO

Glue Binders07 Yellow Mastic (Yellow) 100% 01/29100% DO

Glue Binders08 Yellow Mastic (Yellow) 100% 01/29100% DO

Glue Binders09 Yellow Mastic (Yellow) 5% 01/29100% DO

Glue Binders09 Blue Mastic (Blue) 95% 01/29100% DO

Project # : GSE-017

Sample Number Layer Components % Of

Sample

Analysis

Date

% of

Layer Analyst

Supplement to PLM Summary Report 2051 Valley View Lane

Farmers Branch, TX 75234

Client :

Project :

Great Southern Engineering

MSFC, Building 4464

Lab Job No. :

Report Date :

09B-00880

01/29/2009

Cellulose Fibers10 Acoustic Tile (Light Grey) 100% 01/2950% DO

Mineral Wool Fibers10 Acoustic Tile (Light Grey) 100% 01/2930% DO

Perlite10 Acoustic Tile (Light Grey) 100% 01/2920% DO

Cellulose Fibers11 Acoustic Tile (Light Grey) 100% 01/2950% DO

Mineral Wool Fibers11 Acoustic Tile (Light Grey) 100% 01/2930% DO

Perlite11 Acoustic Tile (Light Grey) 100% 01/2920% DO

Cellulose Fibers12 Acoustic Tile (Light Grey) 100% 01/2950% DO

Mineral Wool Fibers12 Acoustic Tile (Light Grey) 100% 01/2930% DO

Perlite12 Acoustic Tile (Light Grey) 100% 01/2920% DO

Calcite / Vinyl Binders13 Floor Tile (Beige) 95% 01/29100% DO

Tar Binders13 Black Mastic (Black) 5% 01/29100% DO

Calcite / Vinyl Binders14 Floor Tile (Beige) 95% 01/29100% DO

Calcite14 Yellow Mastic (Yellow) 5% 01/2940% DO

Glue Binders14 Yellow Mastic (Yellow) 5% 01/2960% DO

Calcite / Vinyl Binders15 Floor Tile (Beige) 95% 01/29100% DO

Calcite15 Yellow Mastic (Yellow) 5% 01/2940% DO

Glue Binders15 Yellow Mastic (Yellow) 5% 01/2960% DO

Mineral Wool Fibers16 Insulation (Yellow) 90% 01/2995% DO

Resin Binders16 Insulation (Yellow) 90% 01/295% DO

Cellulose Fibers16 Paper / Foil Wrap (Tan / Silver) 5% 01/2960% DO

Glass Wool Fibers16 Paper / Foil Wrap (Tan / Silver) 5% 01/2920% DO

Metal Foil16 Paper / Foil Wrap (Tan / Silver) 5% 01/2920% DO

Wollastonite16 White Mastic (White) 5% 01/295% DO

Pigment / Binders16 White Mastic (White) 5% 01/2995% DO

Project # : GSE-017

Sample Number Layer Components % Of

Sample

Analysis

Date

% of

Layer Analyst

Supplement to PLM Summary Report 2051 Valley View Lane

Farmers Branch, TX 75234

Client :

Project :

Great Southern Engineering

MSFC, Building 4464

Lab Job No. :

Report Date :

09B-00880

01/29/2009

Mineral Wool Fibers17 Insulation (Yellow) 90% 01/2995% DO

Resin Binders17 Insulation (Yellow) 90% 01/295% DO

Cellulose Fibers17 Paper / Foil Wrap (Tan / Silver) 5% 01/2960% DO

Glass Wool Fibers17 Paper / Foil Wrap (Tan / Silver) 5% 01/2920% DO

Metal Foil17 Paper / Foil Wrap (Tan / Silver) 5% 01/2920% DO

Wollastonite17 White Mastic (White) 5% 01/295% DO

Pigment / Binders17 White Mastic (White) 5% 01/2995% DO

Mineral Wool Fibers18 Insulation (Yellow) 90% 01/2995% DO

Resin Binders18 Insulation (Yellow) 90% 01/295% DO

Cellulose Fibers18 Paper / Foil Wrap (Tan / Silver) 5% 01/2960% DO

Glass Wool Fibers18 Paper / Foil Wrap (Tan / Silver) 5% 01/2920% DO

Metal Foil18 Paper / Foil Wrap (Tan / Silver) 5% 01/2920% DO

Wollastonite18 White Mastic (White) 5% 01/295% DO

Pigment / Binders18 White Mastic (White) 5% 01/2995% DO

Glue Binders19 Clear Mastic (Clear) 100% 01/29100% DO

Glue Binders20 Clear Mastic (Clear) 100% 01/29100% DO

Glue Binders21 Clear Mastic (Clear) 100% 01/29100% DO

Synthetic Fibers22 Pad (Black) 95% 01/2925% DO

Rubber22 Pad (Black) 95% 01/2975% DO

Glue Binders22 Yellow Mastic (Yellow) 5% 01/29100% DO

Synthetic Fibers23 Pad (Black) 95% 01/2925% DO

Rubber23 Pad (Black) 95% 01/2975% DO

Glue Binders23 Yellow Mastic (Yellow) 5% 01/29100% DO

Synthetic Fibers24 Pad (Black) 95% 01/2925% DO

Rubber24 Pad (Black) 95% 01/2975% DO

Glue Binders24 Yellow Mastic (Yellow) 5% 01/29100% DO

Cellulose Fibers25 Acoustic Tile (Light Grey) 100% 01/2950% DO

Mineral Wool Fibers25 Acoustic Tile (Light Grey) 100% 01/2930% DO

Perlite25 Acoustic Tile (Light Grey) 100% 01/2920% DO

Project # : GSE-017

Sample Number Layer Components % Of

Sample

Analysis

Date

% of

Layer Analyst

Supplement to PLM Summary Report 2051 Valley View Lane

Farmers Branch, TX 75234

Client :

Project :

Great Southern Engineering

MSFC, Building 4464

Lab Job No. :

Report Date :

09B-00880

01/29/2009

Cellulose Fibers26 Acoustic Tile (Light Grey) 100% 01/2950% DO

Mineral Wool Fibers26 Acoustic Tile (Light Grey) 100% 01/2930% DO

Perlite26 Acoustic Tile (Light Grey) 100% 01/2920% DO

Cellulose Fibers27 Acoustic Tile (Light Grey) 100% 01/2950% DO

Mineral Wool Fibers27 Acoustic Tile (Light Grey) 100% 01/2930% DO

Perlite27 Acoustic Tile (Light Grey) 100% 01/2920% DO

Calcite / Vinyl Binders28 Cove Base (Black) 98% 01/29100% DO

Calcite28 Cream Mastic (Cream) 2% 01/2950% DO

Glue Binders28 Cream Mastic (Cream) 2% 01/2950% DO

Calcite / Vinyl Binders29 Cove Base (Black) 95% 01/29100% DO

Calcite29 Cream Mastic (Cream) 5% 01/2950% DO

Glue Binders29 Cream Mastic (Cream) 5% 01/2950% DO

Calcite / Vinyl Binders30 Cove Base (Black) 95% 01/29100% DO

Calcite30 Cream Mastic (Cream) 5% 01/2950% DO

Glue Binders30 Cream Mastic (Cream) 5% 01/2950% DO

Calcite31 Mastic (White) 100% 01/2950% DO

Binders / Fillers31 Mastic (White) 100% 01/2950% DO

Calcite32 Mastic (White) 100% 01/2950% DO

Binders / Fillers32 Mastic (White) 100% 01/2950% DO

Calcite33 Mastic (White) 100% 01/2950% DO

Binders / Fillers33 Mastic (White) 100% 01/2950% DO

Mineral Wool Fibers34 Insulation (Yellow) 90% 01/2995% DO

Resin Binders34 Insulation (Yellow) 90% 01/295% DO

Cellulose Fibers34 Paper / Foil Wrap (Tan / Silver) 5% 01/2960% DO

Glass Wool Fibers34 Paper / Foil Wrap (Tan / Silver) 5% 01/2920% DO

Metal Foil34 Paper / Foil Wrap (Tan / Silver) 5% 01/2920% DO

Wollastonite34 White Mastic (White) 5% 01/295% DO

Pigment / Binders34 White Mastic (White) 5% 01/2995% DO

Project # : GSE-017

Sample Number Layer Components % Of

Sample

Analysis

Date

% of

Layer Analyst

Supplement to PLM Summary Report 2051 Valley View Lane

Farmers Branch, TX 75234

Client :

Project :

Great Southern Engineering

MSFC, Building 4464

Lab Job No. :

Report Date :

09B-00880

01/29/2009

Mineral Wool Fibers35 Insulation (Yellow) 90% 01/2995% DO

Resin Binders35 Insulation (Yellow) 90% 01/295% DO

Cellulose Fibers35 Paper / Foil Wrap (Tan / Silver) 5% 01/2960% DO

Glass Wool Fibers35 Paper / Foil Wrap (Tan / Silver) 5% 01/2920% DO

Metal Foil35 Paper / Foil Wrap (Tan / Silver) 5% 01/2920% DO

Wollastonite35 White Mastic (White) 5% 01/295% DO

Pigment / Binders35 White Mastic (White) 5% 01/2995% DO

Mineral Wool Fibers36 Insulation (Yellow) 90% 01/2995% DO

Resin Binders36 Insulation (Yellow) 90% 01/295% DO

Cellulose Fibers36 Paper / Foil Wrap (Tan / Silver) 5% 01/2960% DO

Glass Wool Fibers36 Paper / Foil Wrap (Tan / Silver) 5% 01/2920% DO

Metal Foil36 Paper / Foil Wrap (Tan / Silver) 5% 01/2920% DO

Wollastonite36 White Mastic (White) 5% 01/295% DO

Pigment / Binders36 White Mastic (White) 5% 01/2995% DO

Mineral Wool Fibers37 Insulation (Yellow) 90% 01/2995% DO

Resin Binders37 Insulation (Yellow) 90% 01/295% DO

Cellulose Fibers37 Paper / Foil Wrap (Tan / Silver) 5% 01/2960% DO

Glass Wool Fibers37 Paper / Foil Wrap (Tan / Silver) 5% 01/2920% DO

Metal Foil37 Paper / Foil Wrap (Tan / Silver) 5% 01/2920% DO

Cellulose Fibers37 Grey Mastic (Light Grey) 5% 01/295% DO

Pigment / Binders37 Grey Mastic (Light Grey) 5% 01/2995% DO

Mineral Wool Fibers38 Insulation (Yellow) 90% 01/2995% DO

Resin Binders38 Insulation (Yellow) 90% 01/295% DO

Cellulose Fibers38 Paper / Foil Wrap (Tan / Silver) 5% 01/2960% DO

Glass Wool Fibers38 Paper / Foil Wrap (Tan / Silver) 5% 01/2920% DO

Metal Foil38 Paper / Foil Wrap (Tan / Silver) 5% 01/2920% DO

Polyethylene Fibers38 Grey Mastic (Grey) 5% 01/295% DO

Wollastonite38 Grey Mastic (Grey) 5% 01/295% DO

Pigment / Binders38 Grey Mastic (Grey) 5% 01/2990% DO

Project # : GSE-017

Sample Number Layer Components % Of

Sample

Analysis

Date

% of

Layer Analyst

Supplement to PLM Summary Report 2051 Valley View Lane

Farmers Branch, TX 75234

Client :

Project :

Great Southern Engineering

MSFC, Building 4464

Lab Job No. :

Report Date :

09B-00880

01/29/2009

Mineral Wool Fibers39 Insulation (Yellow) 90% 01/2995% DO

Resin Binders39 Insulation (Yellow) 90% 01/295% DO

Cellulose Fibers39 Paper / Foil Wrap (Tan / Silver) 5% 01/2960% DO

Glass Wool Fibers39 Paper / Foil Wrap (Tan / Silver) 5% 01/2920% DO

Metal Foil39 Paper / Foil Wrap (Tan / Silver) 5% 01/2920% DO

Polyethylene Fibers39 Grey Mastic (Grey) 5% 01/295% DO

Wollastonite39 Grey Mastic (Grey) 5% 01/295% DO

Pigment / Binders39 Grey Mastic (Grey) 5% 01/2990% DO

Appendix B

ACM Sample Location Drawings

First Floor – East Wing Building 4464

Marshall Space Flight Center Marshall Space Flight Center, AL

Task Order #GSE-017

272614, 24282529

353634339

First Floor West Wing

Marshall Space Flight Center Marshall Space Flight Center, AL

Task Order #GSE-017

02, 051108373839131203, 221920232107

Mezzanine Floor

Marshall Space Flight Center Marshall Space Flight Center, AL

Task Order #GSE-017

Appendix C

ACM Location Diagrams

NOT APPLICABLE

Appendix D

Photographs

Building 4464, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama

PHOTO 1. View of the building PHOTO 2. View of the building

PHOTO 3. View of the building PHOTO 4. Wallboard System

PHOTO 5. Brown cove base and associated mastic PHOTO 6. Blue green carpet and associated mastic

PHOTO 7. 2’ x 2’ ceiling tile with pin holes PHOTO 8. 12” X 12” beige floor tile with brown smudges

PHOTO 9. Pipe insulation with white mastic PHOTO 10. Multicolored carpet and associated mastic

PHOTO 11. Non skid pads and associated mastic PHOTO 12. 2’ x 2’ ceiling tile with textured finish

PHOTO 13. Black cove base and associated mastic PHOTO 14. White mastic on HVAC unit

PHOTO 15. Tank insulation with white mastic PHOTO 16. Pipe insulation with gray mastic

Appendix E

License and Certifications

1. Introduction
2. Summary
2.1. Suspect ACMs
2.2. Recommendations
3. Survey Scope
4. Limitations
5. Survey and Sample Collection Procedure
6. Previous Survey / Plans Review
7. Suspect ACM Materials Not Sampled
8. Survey Sampling Results
9. Appendices
Appendix A Laboratory Results
Appendix B ACM Sample Location Drawings
Appendix C ACM Location Diagrams
Appendix D Photographs
Appendix E License and Certifications

File details come from the government source that posted it.