This notice provides details for an upcoming Radiology Expansion construction project solicitation to be issued by the Department of Veterans Affairs Technology Acquisition Center Austin. The scope of work involves renovating and expanding an existing radiology area through demolishing an existing 3000 square foot Lab Expansion. New construction and renovations are aimed at optimizing the department footprint with centralized waiting rooms, wide hallways, and sufficiently sized rooms. The project also requires ground level access throughout the Radiology Department and structural preparations for a future second floor addition and elevator. The solicitation will be issued as a Service-Disabled Veteran-Owned Small Business set-aside contract for a firm-fixed price estimated between $5-10 million. The period of performance is approximately 425 calendar days from notice to proceed. The solicitation is scheduled for release on August 8, 2019 with all bids due on the specified date.
36E77619B0012 Attachment 12 - Fire and Plumbing Dwgs.pdf
View the file
Other files
Show 40 more
Latest 50 of 59 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MA
MV
CO
EV
VE
AI
FOV
FOR
FOS
FP
LPG
NPW
NO
O
N
G
MPG
G
MPG
CA
CD
ACD
V
VBG
VBF
AV
AW
AW
ST
OST
GW
GW
S
W
ID
SPD
T
SCW
WS
140°
S
W
ST
CAP
"A"
BAT BATTERY
BC BARE COPPER
BD BOARD
BFF BELOW FINISH FLOOR
BIL BASIC INSULATION LEVEL
BLDG BUILDING
BPIP BOILER PLANT
PANEL
BRKR BREAKER
BYP BY PASS
HID HIGH INTENSITY DISCHARGE
HOA HAND-OFF-AUTOMATIC
HP HORSEPOWER
HT HEIGHT
HZ HERTZ
A/C AIR CONDITIONING
A/E ARCHITECT/ENGINEER
AAP ALARM ANNUNCIATOR PANEL
AC ALTERNATING CURRENT OR ARMORED
CABLE
ACC ACCESSIBLE
ADDL ADDITIONAL
ADJ ADJACENT, ADJOINING
ADO AUTOMATIC DOOR OPENER
AF AMPERE FRAME OR AMP FUSE
AFC ABOVE FINISHED COUNTER, AUTOMATIC
FREQUENCY CONTROL, OR
AVAILABLE FAULT CURRENT
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AH AMPERE HOUR
AHJ AUTHORITY HAVING JURISDICTION
AIC AMPERE INTERRUPTING CAPACITY
ALT ALTERNATE
AMB OR A AMBIENT
AMP AMPERE
ARCH ARCHITECT
ASC AMPS SHORT CIRCUIT
AT AMPERE TRIP
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AV AUDIO VISUAL
1P SINGLE POLE
1PH SINGLE-PHASE
3P THREE POLE
3PH THREE-PHASE
3W THREE WIRE
4W FOUR WIRE
P POLE
PA PUBLIC ADDRESS
PB PANELBOARD, PULL BOX, OR
PUSHBUTTON
PBPU PREFABRICATED BEDSIDE PATIENT UNIT
PCB POLYCHLORINATED BIPHENYL
PEC PHOTOELECTRIC CELL
PED PEDESTAL
PEND PENDANT
PF POWER FACTOR
PH PHASE
PNL PANEL
POD POWER OPERATED DAMPER
PT POTENTIAL TRANSFORMER
PTRV POWER TYPE ROOF VENTILATION
PVC POLYVINYL CHLORIDE (PLASTIC)
PWR POWER
SCC SHORT CIRCUIT CAPACITY
SES SERVICE ENTRANCE SECTION
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SHT SHEET
SI INTERNATIONAL SYSTEM OF UNITS
SPEC SPECIFICATION
SPST SINGLE POLE, SINGLE THROW
SURF SURFACE
SW SWITCH
SWBD SWITCHBOARD
SWGR SWITCHGEAR
G OR GND GROUND OR GENERATOR
GEN GENERATOR
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GTB GROUND TERMINAL BOX
IESNA ILLUMINATION ENGINEERING SOCIETY
OF NORTH AMERICA
IMC INTERMEDIATE METAL CONDUIT
INCAND INCANDESCENT
IR INFRARED
IWH INSTANTANEOUS WATER HEATER
W WATT
WH WATER HEATER
WP WEATHERPROOF
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LM LUMEN
LP LIGHT POLE
LPS LOW PRESSURE SODIUM
LRA LOCKED ROTOR AMPS
LTCP LOCAL TEMPERATURE CONTROL PANEL
LT LIGHT
LTG LIGHTING
LTG PNL LIGHTING PANEL
LTNG LIGHTNING
LV LOW VOLTAGE
XFER TRANSFER
XFMR TRANSFORMER
XP EXPLOSION PROOF
JB JUNCTION BOX
J-BOX JUNCTION BOX
KV KILOVOLT
KVA KILOVOLT AMPERE
KVAH KILOVOLT AMPERE PER HOUR
KVAR KILOVOLT AMPERE REACTIVE
KW KILOWATT
KWH KILOWATT HOUR
KWHM KILOWATT HOUR METER
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MC METAL-CLAD
MCA MINIMUM CIRCUIT AMPS
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDP MAIN DISTRIBUTION PANEL
MECH MECHANICAL
MG MOTOR GENERATOR
MH MANHOLE
MIN MINIMUM
MOCP MAXIMUM OVERCURRENT PROTECTION
MLO MAIN LUGS ONLY
MT MOUNT
MTD MOUNTED
MTG MOUNTING
MTS MANUAL TRANSFER SWITCH
MV MEDIUM VOLTAGE
MVA MEGAVOLT-AMPERE
MW MEGAWATT
OC ON CENTER
OD OUTSIDE DIAMETER
OL OVERLOAD
N NEUTRAL
NA NOT APPLICABLE
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NO NORMALLY OPEN
NS NO SCALE
NTS NOT TO SCALE
RCP REFLECTED CEILING PLAN
RCPT RECEPTACLE
REC RECESSED
RGS RIGID GALVANIZED STEEL
RM ROOM
RMS ROOT MEAN SQUARE
REQD REQUIRED
TC TIME CLOCK
TEL TELEPHONE
TP TWISTED PAIR
TPS TWISTED PAIR SHIELDED
TTB TELEPHONE TERMINAL BOARD
TV TELEVISION
TYP TYPICAL
V VOLT
VA VOLT AMPERE
VAR VOLT AMPERE REACTIVE
VFD VARIABLE FREQUENCY DRIVE
VOLT VOLTAGE
UFD UNDERFLOOR DUCT
UGND UNDERGROUND
UL UNDERWRITERS LABORATORY
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER SUPPLY
UTIL UTILITY
ABBREVIATIONS
A
B
C
C CONDUIT
CAP CAPACITY
CAT CATALOG
CATV COMMUNITY ANTENNA TELEVISION
CCR CONTROL CONTACTOR
CCTV CLOSED CIRCUIT TELEVISION
cd CANDELA
CD CONSTRUCTION DOCUMENTS
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/
CONTRACTOR INSTALLED
CF/OI CONTRACTOR FURNISHED/OWNER
CFE CONTRACTOR FURNISHED
EQUIPMENT
CHW CHILLED WATER
CHWP CHILLED WATER PUMP
CKT CIRCUIT
CKT BRKR CIRCUIT BREAKER
CLF CURRENT LIMITING FUSE
CLG CEILING
CMU CONCRETE MASONRY UNIT
COAX COAX CABLE
COMM COMMUNICATION
CONC CONCRETE
CONT CONTINUE
CONTR CONTRACTOR
COORD COORDINATE
CPT CONTROL POWER TRANSFORMER
CRI COLOR RENDERING INDEX
CT CURRENT TRANSFORMER
CTV CABLE TELEVISION
CU COPPER
CU FT CUBIC FEET
DB DECIBEL OR DIRECT BURIAL
DC DIRECT CURRENT
DCP DIMMER CONTROL PANEL
DEG C DEGREES CELSIUS
DEG F DEGREES FAHRENHEIT
DEMO DEMOLITION
DIAG DIAGRAM
DISC DISCONNECT
DISTR DISTRIBUTION
DISTR PNL DISTRIBUTION PANEL
DN DOWN
DPDT DOUBLE POLE, DOUBLE THROW
DPST DOUBLE POLE, SINGLE THROW
DRSW DOOR SWITCH
DS DISCONNECT SWITCH
DWG DRAWING
EC EMPTY CONDUIT
EG EQUIPMENT GROUND
EL ELEVATION
ELEC ELECTRIC OR ELECTRICAL
ELEV ELEVATOR
EMCP EMERGENCY MONITORING
CONTROL PANEL
EMER EMERGENCY
EMI ELECTROMAGNETIC INTERFERENCE
EMT ELECTRICAL METALLIC TUBING
ENCL ENCLOSURE
EPO EMERGENCY POWER OFF
ESMT EASEMENT
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EXIST EXISTING
D
E
F
G
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FABL FIRE ALARM BELL
FABX FIRE ALARM BOX
FACP FIRE ALARM CONTROL PANEL
FC FOOTCANDLE
FI FILM ILLUMINATOR
FIXT FIXTURE
FLA FULL LOAD AMPS
FLEX FLEXIBLE METALLIC CONDUIT
FLUOR FLUORESCENT
FP FIRE PROTECTION
FT FEET OR FOOT
FVNR FULL VOLTAGE NON-REVERSING
FVR FULL VOLTAGE REVERSING
H
I
J
K
L
M
N
O
P
ANNOTATION
R
S
T
U
V
W
W
CU
M100
M100
MECHANICAL OR FIRE SPRINKLER PLAN NOTE CALL OUT
PLUMBING PLAN NOTE CALL OUT
ELECTRICAL OR FIRE ALARM PLAN NOTE CALL OUT
TECHNOLOGY PLAN NOTE CALL OUT
PLUMBING EQUIPMENT DESIGNATION
EQUIPMENT DESIGNATION TAG
OWNER FURNISHED, CONTRACTOR INSTALLED
EQUIPMENT DESIGNATION
NEW WORK TO EXISTING WORK CONNECTION POINT
DETAIL REFERENCE
SECTION CUT DESIGNATION
PIPING SYMBOLS
FIRE SPRINKLERS
FIRE PIPING
PENDENT SPRINKLER
UPRIGHT SPRINKLER
CONCEALED SPRINKLER
DRY PENDENT SPRINKLER
DRY SIDEWALL SPRINKLER
SIDEWALL SPRINKLER
WITH PDI SIZES, (A, B, C, D, & E)
WATER HAMMER ARRESTER (WHA)
FIRE DEPARTMENT CONNECTION
FIRE PUMP TEST HEADER
INSPECTOR'S TEST CONNECTION / AUXILIARY DRAIN
SPRINKLER RISER
FLOOR DRAIN (FD), SIZE & TYPE
ROOF DRAIN (RD), SIZE & TYPE
NITROUS OXIDE OUTLET
NITROGEN OUTLET
MEDICAL VACUUM INLET
OXYGEN OUTLET
MEDICAL AIR OUTLET
FLOOR SINK (FS), SIZE & TYPE
NATURAL GAS ON ROOF (G)
SUMP OR SEWAGE PUMP DISCHARGE (SPD)
CONDENSATE DRAIN (CD)
INDIRECT DRAIN (ID)
NATURAL GAS (G)
NITROUS OXIDE (NO)
LIQUIFIED PETROLEUM GAS (LPG)
FIRE PROTECTION (FP)
WATER SERVICE (WS)
COMPRESSED AIR (CA)
NITROGEN (N)
MEDICAL AIR (MA)
OXYGEN (O)
DOMESTIC HOT WATER RECIRC.
SOIL PIPING - ABOVE FLOOR (S)
SOIL PIPING - BELOW FLOOR (S)
STORM DRAIN - ABOVE FLOOR (ST)
STORM DRAIN - BELOW FLOOR (ST)
ACID WASTE - ABOVE FLOOR (AW)
ACID WASTE - BELOW FLOOR (AW)
DOMESTIC COLD WATER
DOMESTIC HOT WATER
140° DOMESTIC HOT WATER (140°)
WASTE PIPING - ABOVE FLOOR (W)
WASTE PIPING - BELOW FLOOR (W)
GREASE WASTE - ABOVE FLOOR (GW)
GREASE WASTE - BELOW FLOOR (GW)
SOFTENED COLD WATER (SCW)
ACID VENT (AV)
VENT PIPING (V)
HOSE BIBB (HB)
NONFREEZE WALL HYDRANT (NW)
WALL CLEANOUT (WCO)
FLOOR CLEANOUT (FCO)
EXTERIOR CLEANOUT (ECO)
THERMOSTATIC MIXING VALVE
BACKFLOW PREVENTER
GAS PRESSURE REGULATOR
OVERFLOW STORM DRAIN - ABOVE FLOOR (OST)
NON POTABLE WATER (NPW)
FUEL OIL SUPPLY (FOS)
FUEL OIL RETURN (FOR)
FUEL OIL VENT (FOV)
AUXILIARY CONDENSATE DRAIN (ACD)
VENT BELOW GRADE (VBG)
VENT BELOW FLOOR (VBF)
CARBON DIOXIDE (CO)
MEDICAL VACUUM (MV)
EVACUATION (EV)
MEDICAL VACUUM EXHAUST (VE)
MEDICAL AIR INTAKE (AI)
TRAP PRIMER LINE (T)
WATER METER
MEDIUM PRESSURE NATURAL GAS (MPG)
MEDIUM PRESSURE NATURAL GAS ON ROOF (MPG)
ELBOW DOWN WITH SHUT-OFF VALVE (SOV)
TEE DOWN WITH SHUT-OFF VALVE (SOV)
TEE UP WITH SHUT-OFF VALVE (SOV)
RECIRCULATION PUMP
DIRECTION OF FLOW
EXISTING PIPING TO REMAIN
EXISTING PIPING TO BE REMOVED
FLANGE CONNECTION
CLEANOUT
ELBOW DOWN
ELBOW UP
TEE DOWN
ELBOW UP WITH SHUT-OFF VALVE (SOV)
TEE UP
UNION
THERMOMETER
PRESSURE GAUGE
BALL VALVE
SHUTOFF VALVE
CHECK VALVE
PRESSURE REDUCING VALVE
REDUCER
Drawing Number
Project Number
Date
Project Title
Building NumberLocation
Checked DrawnAPPROVED: CHIEF ENGINEER
Drawing Title
VA FORM
Office of Construction and Facilities Management
Dwg
CIVIL / STRUCTURAL ENGINEER M.E.P. / T. ENGINEER
APPROVED: DIRECTOR
APPROVED: ASSOCIATE DIRECTOR
APPROVED: ASSISTANT DIRECTOR APPROVED: CHIEF ENGINEER
REVISIONS DATE
CONSULTANTS ARCHITECT
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
A
1 2 3 4 5 6 7 8 9
B
C
D
E
F
A
B
C
D
E
F
H2B
1225 NORTH LOOP WEST, SUITE 900
HOUSTON, TX 77008
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
AZ ARCH REG. NO. 20013-0, EXP. 10/10/2019
AZ ENGR REG. NO. 20015-0, EXP. 10/10/2019 -OF- 148
RADIOLOGY EXPANSIONFIRE SPRINKLER LEGEND
649-413
11/01/18 JES RLC
107-F-000
100% BACKCHECK SUBMITTAL
DEPARTMENT OF VETERAN AFFAIRS
NORTHERN ARIZONA VA HEALTH CARE SYSTEM
500 HWY 89N
PRESCOTT AZ, 86313
62EXPIRES 12/31/2019
ZONE A
ZONE C
ZONE B
FIRE PUMP ROOM
STANDPIPE
STANDPIPE
STANDPIPE
ZONE A
ZONE C
ZONE C
ZONE B
11 22
BB BB
AA AA
ZONE 1-A
Z O
N E
-C
ZONE 1-A
ZONE 1-A
FP (ETR)
F P
E
T R
FP (ETR)
FP (ETR)
F P
E
T R
F P
E
T R
Drawing Number
Project Number
Date
Project Title
Building NumberLocation
Checked DrawnAPPROVED: CHIEF ENGINEER
Drawing Title
VA FORM
Office of Construction and Facilities Management
Dwg
CIVIL / STRUCTURAL ENGINEER M.E.P. / T. ENGINEER
APPROVED: DIRECTOR
APPROVED: ASSOCIATE DIRECTOR
APPROVED: ASSISTANT DIRECTOR APPROVED: CHIEF ENGINEER
REVISIONS DATE
CONSULTANTS ARCHITECT
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
A
1 2 3 4 5 6 7 8 9
B
C
D
E
F
A
B
C
D
E
F
H2B
1225 NORTH LOOP WEST, SUITE 900
HOUSTON, TX 77008
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
AZ ARCH REG. NO. 20013-0, EXP. 10/10/2019
AZ ENGR REG. NO. 20015-0, EXP. 10/10/2019 -OF- 148
RADIOLOGY EXPANSIONFIRE SPRINKLER DEMOLITION
BASEMENT FLOOR PLAN
649-413
11/01/18 JES RLC
107-FXD100
100% BACKCHECK SUBMITTAL
DEPARTMENT OF VETERAN AFFAIRS
NORTHERN ARIZONA VA HEALTH CARE SYSTEM
500 HWY 89N
PRESCOTT AZ, 86313
1/8" = 1'-0"
FIRE SPRINKLER DEMOLITION
BASEMENT FLOOR PLAN
N
GENERAL NOTES:
1. THE AREA OF WORK SHOWN IS ASSOCIATED WITH AN OPERATING FACILITY THAT MUST REMAIN
IN SERVICE 24 HOURS A DAY, 7 DAYS A WEEK.
2. COORDINATE WORK SCHEDULE WITH THE CONTRACTING OFFICER'S REPRESENTATIVE.
3. COORDINATE FIRE SPRINKLER WORK WITH ALL OTHER TRADES. VERIFY ALL EXISTING
CONDITIONS BEFORE THE START OF WORK.
4. SEE SHEET GI001 FOR ADDITIONAL INFORMATION REGARDING SCHEDULE AND PHASING
REQUIREMENTS. SCHEDULE WORK IN THE EXISTING BUILDING TO MINIMIZE DISRUPTION OF
SERVICES.
5. EXISTING FIRE SPRINKLER LAYOUT INFORMATION HAS BEEN PROVIDED AS A REFERENCE.
FIELD VERIFY ACTUAL CONDITIONS. PROVIDE ASBUILT CONDITIONS AS PART OF THIS SCOPE
OF WORK.
FIRE SPRINKLER PLAN NOTES:
1. EXISTING FIRE SPRINKLER MAIN IN BASEMENT IS EXISTING TO REMAIN (ETR).
2. EXISTING ABANDONED FIRE SPRINKLER LINE IN BASEMENT IS EXISTING TO REMAIN (ETR).
3. REMOVE EXISTING FIRE DEPARTMENT CONNECTION AND ASSOCIATED PIPING TO DEMARCATION
POINT SHOWN. PREPARE PIPING TO BE ROUTED TO NEW FIRE DEPARTMENT CONNECTION. SEE
SHEET 107-FX-100 FOR RELATED WORK.
4. MODIFY EXISTING FIRE SPRINKLER AS REQUIRED WHERE EXISTING DENTAL AHU AND ASSOCIATED
PIPING, DUCTWORK, AND COMPONENTS ARE REMOVED. SEE 107-MHD100 FOR MECHANICAL
DEMOLITION SCOPE.
5. MODIFY EXISTING FIRE SPRINKLER PIPING AND SPRINKLER HEADS AS REQUIRED WHERE EXISTING EXHAUST DUCTWORK IS REMOVED. SEE SHEET 107-MHD100 FOR MECHANICAL DEMOLITION SCOPE.
EXPIRES 12/31/2019
ZONE B
FIRE PUMP ROOM
STANDPIPE
STANDPIPE
STANDPIPE
ZONE A
ZONE C
ZONE C
ZONE B
11 22
BB BB
AA AA
AREA OF DEMOLITION
ZONE 1-A
Z O
N E
-C
ZONE 1-A
ZONE 1-A
BID DEDUCT
ALTERNATE #2
BID DEDUCT
ALTERNATE #1
FP FP
F P
F P
BID DEDUCT
ALTERNATE #2
Drawing Number
Project Number
Date
Project Title
Building NumberLocation
Checked DrawnAPPROVED: CHIEF ENGINEER
Drawing Title
VA FORM
Office of Construction and Facilities Management
Dwg
CIVIL / STRUCTURAL ENGINEER M.E.P. / T. ENGINEER
APPROVED: DIRECTOR
APPROVED: ASSOCIATE DIRECTOR
APPROVED: ASSISTANT DIRECTOR APPROVED: CHIEF ENGINEER
REVISIONS DATE
CONSULTANTS ARCHITECT
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
A
1 2 3 4 5 6 7 8 9
B
C
D
E
F
A
B
C
D
E
F
H2B
1225 NORTH LOOP WEST, SUITE 900
HOUSTON, TX 77008
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
AZ ARCH REG. NO. 20013-0, EXP. 10/10/2019
AZ ENGR REG. NO. 20015-0, EXP. 10/10/2019 -OF- 148
RADIOLOGY EXPANSIONFIRE SPRINKLER DEMOLITION
FIRST FLOOR PLAN
649-413
11/01/18 JES RLC
107-FXD101
100% BACKCHECK SUBMITTAL
DEPARTMENT OF VETERAN AFFAIRS
NORTHERN ARIZONA VA HEALTH CARE SYSTEM
500 HWY 89N
PRESCOTT AZ, 86313
N
FIRE SPRINKLER DEMO PLAN NOTES:
1. BUILDING ZONE 1-A FIRE SPRINKLER TO BE REMOVED BACK TO RISER IN STAIRWELL. PROVIDE TEMPORARY VALVE AND CAP IN LOCATION SHOWN. SEE SHEET 107-FX-101 FOR RELATED WORK.
2. BUILDING ZONE 1-C FIRE SPRINKLER TO BE REMOVED TO DEMARCATION POINT SHOWN. PROVIDE TEMPORARY VALVE AND CAP IN LOCATION SHOWN.. SEE SHEET 107-FX-101 FOR RELATED WORK.
3. REMOVE FIRE DEPARTMENT CONNECTION AND ASSOCIATED PIPING IN LOCATION SHOWN. PREPARE EXISTING PIPING TO BE ROUTED TO NEW FIRE DEPARTMENT CONNECTION. SEE SHEETS 107-FX-100
AND 107-FX-101 FOR RELATED WORK.
1/8" = 1'-0"
FIRE SPRINKLER DEMOLITION FIRST
FLOOR PLAN
GENERAL NOTES:
1. THE AREA OF WORK SHOWN IS ASSOCIATED WITH AN OPERATING FACILITY THAT MUST REMAIN
IN SERVICE 24 HOURS A DAY, 7 DAYS A WEEK.
2. COORDINATE WORK SCHEDULE WITH THE CONTRACTING OFFICER'S REPRESENTATIVE.
3. COORDINATE FIRE SPRINKLER WORK WITH ALL OTHER TRADES. VERIFY ALL EXISTING
CONDITIONS BEFORE THE START OF WORK.
4. SEE SHEET GI001 FOR ADDITIONAL INFORMATION REGARDING SCHEDULE AND PHASING
REQUIREMENTS. SCHEDULE WORK IN THE EXISTING BUILDING TO MINIMIZE DISRUPTION OF
SERVICES.
5. EXISTING FIRE SPRINKLER LAYOUT INFORMATION HAS BEEN PROVIDED AS A REFERENCE.
FIELD VERIFY ACTUAL CONDITIONS. PROVIDE ASBUILT CONDITIONS AS PART OF THIS SCOPE
OF WORK.
BID DEDUCT ALTERNATE NOTES:
1. BID DEDUCT ALTERNATE #1: IF DEDUCT ALTERNATE IS CHOSEN, EXISTING PIPE AND ACCESSORIES
TO REMAIN. SEE 107-FX101 FOR RELATED INFORMATION.
2. BID DEDUCT ALTERNATE #2: IF DEDUCT ALTERNATE IS CHOSEN, EXISTING PIPE AND ACCESSORIES
TO REMAIN. SEE 107-FX101 FOR RELATED INFORMATION.
3. BID DEDUCT ALTERNATE #3: IF DEDUCT ALTERNATE IS CHOSEN, NO CHANGES ARE NECESSARY. SEE
107-FX101 FOR RELATED INFORMATION.
ZONE B
FIRE PUMP ROOM
STANDPIPE
STANDPIPE
STANDPIPE
ZONE A
ZONE C
ZONE C
ZONE B
F
BB
CC
DD
1 3 42 5
B.1
E
6 9
2.1
F.1
E.1
A.5
A.1
D.2
D.1
A
1.1 7
C.2
B.2
4.5 8
G
8.1
B.9
F P
F P
CT SCANNER EQUIP. RM
112 SF
BASEMENT
5212 SF
ZONE 1-A
Z O
N E
-C
ZONE 1-A
ZONE 1-A
FP (ETR)
F P
E
T R
FP (ETR)
FP (ETR)
F P
E
T R
F P
E
T R
Drawing Number
Project Number
Date
Project Title
Building NumberLocation
Checked DrawnAPPROVED: CHIEF ENGINEER
Drawing Title
VA FORM
Office of Construction and Facilities Management
Dwg
CIVIL / STRUCTURAL ENGINEER M.E.P. / T. ENGINEER
APPROVED: DIRECTOR
APPROVED: ASSOCIATE DIRECTOR
APPROVED: ASSISTANT DIRECTOR APPROVED: CHIEF ENGINEER
REVISIONS DATE
CONSULTANTS ARCHITECT
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
A
1 2 3 4 5 6 7 8 9
B
C
D
E
F
A
B
C
D
E
F
H2B
1225 NORTH LOOP WEST, SUITE 900
HOUSTON, TX 77008
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
AZ ARCH REG. NO. 20013-0, EXP. 10/10/2019
AZ ENGR REG. NO. 20015-0, EXP. 10/10/2019 -OF- 148
RADIOLOGY EXPANSIONFIRE SPRINKLER BASEMENT
FLOOR PLAN
649-413
11/01/18 JES RLC
107-FX-100
100% BACKCHECK SUBMITTAL
DEPARTMENT OF VETERAN AFFAIRS
NORTHERN ARIZONA VA HEALTH CARE SYSTEM
500 HWY 89N
PRESCOTT AZ, 86313
1/8" = 1'-0"
FIRE SPRINKLER BASEMENT FLOOR
PLAN
N
GENERAL NOTES:
1. THE AREA OF WORK SHOWN IS ASSOCIATED WITH AN OPERATING FACILITY THAT MUST REMAIN
IN SERVICE 24 HOURS A DAY, 7 DAYS A WEEK.
2. COORDINATE WORK SCHEDULE WITH THE CONTRACTING OFFICER'S REPRESENTATIVE.
3. COORDINATE FIRE SPRINKLER WORK WITH ALL OTHER TRADES. VERIFY ALL EXISTING
CONDITIONS BEFORE THE START OF WORK.
4. SEE SHEET GI001 FOR ADDITIONAL INFORMATION REGARDING SCHEDULE AND PHASING
REQUIREMENTS. SCHEDULE WORK IN THE EXISTING BUILDING TO MINIMIZE DISRUPTION OF
SERVICES.
5. EXISTING FIRE SPRINKLER LAYOUT INFORMATION HAS BEEN PROVIDED AS A REFERENCE.
FIELD VERIFY ACTUAL CONDITIONS. PROVIDE ASBUILT CONDITIONS AS PART OF THIS SCOPE
OF WORK.
FIRE SPRINKLER PLAN NOTES:
1. EXISTING FIRE SPRINKLER MAIN IN BASEMENT IS EXISTING TO REMAIN (ETR).
2. EXISTING ABANDONED FIRE SPRINKLER LINE IN BASEMENT IS EXISTING TO REMAIN (ETR).
3. CONNECT NEW FIRE SPRINKLER PIPING TO EXISTING FIRE SPRINKLER MAIN IN LOCATION SHOWN.
ROUTE PIPING TO NEW FIRE DEPT. CONNECTION AS SHOWN.
4. MODIFY EXISTING FIRE SPRINKLER AND SPRINKLER HEADS AS REQUIRED TO ACCOMODATE NEW
MECHANICAL PIPING AND EQUIPMENT AS SHOWN ON SHEET 107-MP-100.
5. MODIFY EXISTING FIRE SPRINKLER PIPING AND SPRINKLER HEADS AS REQUIRED TO ACCOMODATE
NEW EXHAUST DUCTWORK AS SHOWN ON SHEET 107-MH-100.
6. PROVIDE NEW FIRE DEPARTMENT CONNECTION IN LOCATION SHOWN.
ZONE B
FIRE PUMP ROOM
STANDPIPE
STANDPIPE
STANDPIPE
ZONE A
ZONE C
ZONE C
ZONE B
FF
BB
CC
DD
3 42 5
B.1
EE
6 9
2.1
F.1F.1
E.1E.1
A.5
A.1A.1
D.2
D.1
AA
1.1
1.1
C.2
B.2
4.5 8
G
8.1
B.9
5 5 5 5
FP FP
F P
F P
F P
F P
F P
ENTRY VESTIBULE
158 SF
NEW ELEC.
298 SF
114 SF
EXISTING MEN'S RR
CORRIDOR
791 SF
STORAGE
40 SF
WOMEN'S TOILET
62 SF
SCHEDULING
141 SF
WAITING
645 SF
RECEPTION
105A
99 SF
WORKROOM
178 SF
ULTRASOUND
179 SF
196 SF
EXISTING STAIRS
INPATIENT HOLDING
120 SF
INPATIENT HOLDING
110 SF
EQUIP. ALCOVE
83 SF
STORAGE
117 SF
COMMS
100 SF
STAFF TOILET
87 SF
PHYS. VIEWING ROOM
107 SF
PHYS. VIEWING ROOM
99 SF
PHYS. VIEWING ROOM
96 SF
PACS
101 SF
ON-CALL ROOM
155 SF
MEETING ROOM
274 SF
SUPERVISOR
120B
105 SF
WORK AREA
191 SF
CHIEF TECHNOLOGIST
120A
102 SF
CORRIDOR
481 SF
Corridor
B104
231 SF
STAFF LOUNGE/TRAINING
441 SF
HAC
58 SF
TOILET
111A
61 SF
ULTRASOUND
184 SF
MRI EQUIP. ROOM
175 SF
MRI SCAN ROOM
146C
346 SF
MRI DRESS
146E
49 SF
MRI DRESS
146F
49 SF
TOILET
109A
65 SF
STAFF TOILET
60 SF
RESTROOM
59 SF
X-RAY TECH
62 SF
STRESS
219 SF
SOILED UTILITY
66 SF
NURSE
142 SF
X-RAY
345 SF
ALCOVE
31 SF
X-RAY
343 SF
ALCOVE
29 SF
ALCOVE
146H
12 SF
ALCOVE
9 SF
ALCOVE
22 SF
CORRIDOR
2106 SF
MEN'S RESTROOM
80 SF
WOMEN'S RESTROOM
81 SF
DRESS
55 SF
DRESS
50 SF
FLUOROSCOPY X-RAY ROOM
376 SF
ALCOVE
38 SF
TOILET
135A
62 SF
CT SCAN ROOM
352 SF
CT CONTROL
211 SF
SPECT CT SCAN ROOM
404 SF
201 SF
RADIOPHARMACY
144A
RADIO DROP-OFF
144B
102 SF
PATIENT DOSE ADMINISTRATION
138 SF
BONE DENSITOMETRY
228 SF
MRI PREP/HOLDING
146A
195 SF
MRI SUB-WAITING
191 SF
MRI CONTROL ROOM
146B
119 SF
BID DEDUCT
ALTERNATE #2
BID DEDUCT
ALTERNATE #1
BID DEDUCT
ALTERNATE #3
ZONE 1-A
Z O
N E
-C
ZONE 1-A
ZONE 1-A
BID DEDUCT
ALTERNATE #2
Drawing Number
Project Number
Date
Project Title
Building NumberLocation
Checked DrawnAPPROVED: CHIEF ENGINEER
Drawing Title
VA FORM
Office of Construction and Facilities Management
Dwg
CIVIL / STRUCTURAL ENGINEER M.E.P. / T. ENGINEER
APPROVED: DIRECTOR
APPROVED: ASSOCIATE DIRECTOR
APPROVED: ASSISTANT DIRECTOR APPROVED: CHIEF ENGINEER
REVISIONS DATE
CONSULTANTS ARCHITECT
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
A
1 2 3 4 5 6 7 8 9
B
C
D
E
F
A
B
C
D
E
F
H2B
1225 NORTH LOOP WEST, SUITE 900
HOUSTON, TX 77008
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
AZ ARCH REG. NO. 20013-0, EXP. 10/10/2019
AZ ENGR REG. NO. 20015-0, EXP. 10/10/2019 -OF- 148
RADIOLOGY EXPANSIONFIRE SPRINKLER LEVEL 1 FLOOR
PLAN
649-413
11/01/18 JES RLC
107-FX-101
100% BACKCHECK SUBMITTAL
DEPARTMENT OF VETERAN AFFAIRS
NORTHERN ARIZONA VA HEALTH CARE SYSTEM
500 HWY 89N
PRESCOTT AZ, 86313
N
FIRE SPRINKLER PLAN NOTES:
1. CONNECT NEW ZONE 1-A FIRE SPRINKLER PIPING TO EXISTING FIRE SPRINKLER RISER IN STAIRWELL.
IN LOCATION SHOWN.
2. CONNECT NEW ZONE 1-C FIRE SPRINKLER PIPING TO EXISTING PIPING IN LOCATION SHOWN.
3. PROVIDE BRANCH CONNECTION OFF NEW FIRE SPRINKLER MAIN IN EXISTING BUILDING 107 AND
ROUTE TO NEW RADIOLOGY EXPANSION AS SHOWN.
4. PROVIDE NON-FERROUS FIRE SPRINKLER PIPING AND ACCESSORIES IN THE MRI SCAN ROOM.
FERROUS MATERIALS ARE NOT PERMITTED. REFER TO MRI MANUFACTURER'S AND RF SHIELD
VENDOR'S INSTALLATION REQUIREMENTS PRIOR TO INSTALLATION OF FIRE SPRINKLER PIPING AND
ACCESSORIES.
5. PROVIDE NEW PIPING PENETRATIONS OF EXISTING CONCRETE STRUCTURAL WALL FOR NEW FIRE SPRINKLER MAIN IN LOCATIONS SHOWN. REUSE EXISTING PIPE PENETRATIONS WHERE POSSIBLE.
6. PROVIDE NEW FIRE DEPARTMENT CONNECTION IN LOCATION SHOWN. SEE SHEET 107-FX-100 FOR
PIPING CONTINUATION.
1/8" = 1'-0"
FIRE SPRINKLER LEVEL 1 FLOOR PLAN
GENERAL NOTES:
1. THE AREA OF WORK SHOWN IS ASSOCIATED WITH AN OPERATING FACILITY THAT MUST REMAIN
IN SERVICE 24 HOURS A DAY, 7 DAYS A WEEK.
2. COORDINATE WORK SCHEDULE WITH THE CONTRACTING OFFICER'S REPRESENTATIVE.
3. COORDINATE FIRE SPRINKLER WORK WITH ALL OTHER TRADES. VERIFY ALL EXISTING
CONDITIONS BEFORE THE START OF WORK.
4. SEE SHEET GI001 FOR ADDITIONAL INFORMATION REGARDING SCHEDULE AND PHASING
REQUIREMENTS. SCHEDULE WORK IN THE EXISTING BUILDING TO MINIMIZE DISRUPTION OF
SERVICES.
5. EXISTING FIRE SPRINKLER LAYOUT INFORMATION HAS BEEN PROVIDED AS A REFERENCE.
FIELD VERIFY ACTUAL CONDITIONS. PROVIDE ASBUILT CONDITIONS AS PART OF THIS SCOPE
OF WORK.
BID DEDUCT ALTERNATE NOTES:
1. BID DEDUCT ALTERNATE #1: IF DEDUCT ALTERNATE IS CHOSEN, COORDINATE CONNECTION TO MAIN IN ZONE 1-A. THERE IS NO NEW WORK IN ZONE 1-C. SEE 107-FXD101 FOR RELATED INFORMATION.
2. BID DEDUCT ALTERNATE #2: IF DEDUCT ALTERNATE IS CHOSEN, COORDINATE CONNECTION TO MAIN.
SEE 107-FXD101 FOR RELATED INFORMATION.
3. BID DEDUCT ALTERNATE #3: IF DEDUCT ALTERNATE IS CHOSEN, PROVIDE SPRINKLER LAYOUT ASSUMING NO CEILING WILL BE INSTALLED. PROVIDE FULL COVERAGE FOR FUTURE DENSITY. SEE
107-FXD101 FOR RELATED INFORMATION.
MA
MV
CO
EV
VE
AI
FOV
FOR
FOS
FP
LPG
NPW
NO
O
N
G
MPG
G
MPG
CA
CD
ACD
V
VBG
VBF
AV
AW
AW
ST
OST
GW
GW
S
W
ID
SPD
T
T
SCW
WS
140°
S
W
ST
CAP
AV
TYPICAL UNIT NO.
BUILDING NO. WHERE EQUIPMENT
PUMP NO.3 IN BUILDING NO.26
EQUIPMENT ABBREVIATION (PUMP)
IS LOCATED.
ORAL EVACUATION
LABORATORY VACUUM
LABORATORY AIR
TEMPERED WATER RETURN
TEMPERED WATER SUPPLY
INDUSTRIAL AIR
LA
LV
OA
IA
TWR
TWS
FILTERED COLD WATERFCW
FUEL OIL DISCHARGEFOD
ANCHOR
CONNECTION - SIDE
ECCENTRIC REDUCER
CONNECTION - BOTTOM, 45° OR 90°
CONNECTION - TOP, 45° OR 90°
DIRECTION OF PIPE PITCH (DOWN)
RISE OR DROP IN PIPE
STRAINER
FLOAT & THERMOSTATIC TRAP SET INCLUDING
PIPING ACCESSORIES
PIPING ACCESSORIES
INVERTED BUCKET TRAP SET INCLUDING
FLOOR DRAIN (FD), SIZE & TYPE
ROOF DRAIN (RD), SIZE & TYPE
FLOOR SINK (FS), SIZE & TYPE
NATURAL GAS BELOW GRADE (G)
SUMP OR SEWAGE PUMP DISCHARGE (SPD)
CONDENSATE DRAIN (CD)
INDIRECT DRAIN (ID)
NATURAL GAS (G)
NITROUS OXIDE (NO)
LIQUIFIED PETROLEUM GAS (LPG)
FIRE PROTECTION (FP)
WATER SERVICE (WS)
COMPRESSED AIR (CA)
NITROGEN (N)
MEDICAL AIR (MA)
OXYGEN (O)
DOMESTIC HOT WATER RECIRC.
SOIL PIPING - ABOVE FLOOR (S)
SOIL PIPING - BELOW FLOOR (S)
STORM DRAIN - ABOVE FLOOR (ST)
STORM DRAIN - BELOW FLOOR (ST)
ACID WASTE - ABOVE FLOOR (AW)
ACID WASTE - BELOW FLOOR (AW)
DOMESTIC COLD WATER
DOMESTIC HOT WATER
140° DOMESTIC HOT WATER (140°)
WASTE PIPING - ABOVE FLOOR (W)
WASTE PIPING - BELOW FLOOR (W)
GREASE WASTE - ABOVE FLOOR (GW)
GREASE WASTE - BELOW FLOOR (GW)
SOFTENED COLD WATER (SCW)
ACID VENT (AV)
VENT PIPING (V)
HOSE BIBB (HB)
NONFREEZE WALL HYDRANT (NW)
WALL CLEANOUT (WCO)
FLOOR CLEANOUT (FCO)
EXTERIOR CLEANOUT (ECO)
THERMOSTATIC MIXING VALVE
BACKFLOW PREVENTER
OVERFLOW STORM DRAIN - ABOVE FLOOR (OST)
NON POTABLE WATER (NPW)
FUEL OIL SUPPLY (FOS)
FUEL OIL RETURN (FOR)
FUEL OIL VENT (FOV)
AUXILIARY CONDENSATE DRAIN (ACD)
VENT BELOW GRADE (VBG)
VENT BELOW FLOOR (VBF)
CARBON DIOXIDE (CO)
MEDICAL VACUUM (MV)
EVACUATION (EV)
MEDICAL VACUUM EXHAUST (VE)
MEDICAL AIR INTAKE (AI)
TRAP PRIMER LINE (T)
WATER METER
MEDIUM PRESSURE NATURAL GAS (MPG)
MEDIUM PRESSURE NATURAL GAS ON ROOF (MPG)
ELBOW DOWN WITH SHUT-OFF VALVE (SOV)
TEE DOWN WITH SHUT-OFF VALVE (SOV)
TEE UP WITH SHUT-OFF VALVE (SOV)
RECIRCULATION PUMP
DIRECTION OF FLOW
EXISTING PIPING TO REMAIN
EXISTING PIPING TO BE REMOVED
FLANGE CONNECTION
CLEANOUT
ELBOW DOWN
ELBOW UP
TEE DOWN
ELBOW UP WITH SHUT-OFF VALVE (SOV)
TEE UP
UNION
THERMOMETER
PRESSURE GAUGE
PRESSURE REDUCING VALVE
REDUCER
SHOWER HEADS
JANITORS SINK
DRINKING FOUNTAIN & TYPE
SHOWER
BATHTUB
TANK TYPE WATER CLOSET
COUNTER TOP LAVATORY & TYPE
WALL MOUNTED LAVATORY & TYPE
URINAL SINK & TYPE
BALL VALVE
GATE VALVE WITH 3/4 " HOSE ADAPTER
CHECK VALVE
ANGLE GLOBE VALVE
BUTTERFLY VALVE
MODULATING CONTROL VALVE
TWO POSITION CONTROL VALVE
THREE-WAY MODULATING CONTROL VALVE
AUTOMATIC FLOW CONTROL VALVE
PRESSURE RELIEF VALVE
GATE VALVE
MANUAL AIR VENT
TEST PLUG (PRESSURE/TEMPERATURE)
GLOBE VALVE
PRESSURE REGULATING VALVE
THREE-WAY TWO POSITION CONTROL VALVE
AUTOMATIC AIR VENT
MECHANICAL OR FIRE SPRINKLER PLAN NOTE CALL OUT
PLUMBING PLAN NOTE CALL OUT
ELECTRICAL OR FIRE ALARM PLAN NOTE CALL OUT
TECHNOLOGY PLAN NOTE CALL OUT
PLUMBING EQUIPMENT DESIGNATION
MECHANICAL EQUIPMENT DESIGNATION TAG
OWNER FURNISHED, CONTRACTOR INSTALLED
EQUIPMENT DESIGNATION
NEW WORK TO EXISTING WORK CONNECTION POINT
DETAIL NUMBER
SHEET NUMBER
LIMIT OF DEMOLITION
TRAP PRIMER LINE - BELOW SLAB (T)
CO
DOUBLE EXTERIOR CLEANOUT (ECO)
CLEANOUTS
DRAINS AND TRAPS
EQUIPMENT
FITTINGS AND ACCESSORIES
SHEET NUMBER
SECTION NUMBER
JANITORS SINK - CORNER
MEDICAL GAS OUTLET (TYPE)
EXISTING TO REMAIN
A
A/E ARCHITECT / ENGINEER
AD AREA DRAIN/ACCESS DOOR
AFF ABOVE FINISH FLOOR
AFG ABOVE FINISH GRADE
AG AIR GAP
AP ACCESS PANEL
AS AUTOMATIC SPRINKLER
ASD ADJUSTABLE SPEED DRIVES
ASD AUTOMATIC SPRINKLER DRAIN
ASHRAE AMERICAN SOCIETY OF HEATING,
REFRIGERATION, AIR CONDITIONING
ENGINEERS
ASME AMERICAN SOCIETY OF ECHANICAL
ENGINEERS
ASPE AMERICAN SOCIETY OF PLUMBING
ENGINEERS
ASR AUTOMATIC SPRINKLER RISER
AV ACID VENT
AW ACID WASTE
B
BFP REDUCED PRESSURE BACKFLOW
PREVENTER
BHP BREAK HORSEPOWER
BSP BLACK STEEL PIPE
BT BATHTUB
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
C
C CELSIUS
CA COMPRESSED AIR
CGA COMPRESSED GAS ASSOCIATION
CFM CUBIC FEET PER MINUTE
CI CAST IRON
CO CLEANOUT
CS CLINICAL SINK
CV CONTROL VALVE
D
DCW DOMESTIC COLD WATER
DFU DRAINAGE FIXTURE UNITS
DHW DOMESTIC HOT WATER
DHWR DOMESTIC HOT WATER RETURN
DHWS DOMESTIC HOT WATER SUPPLY
DI DEIONIZED WATER
DN DOWN
DOE DEPARTMENT OF ENERGY
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
DWH DOMESTIC WATER HEATER
DWR DRINKING WATER RETURN
DWS DRINKING WATER SUPPLY
DWV DRAIN WASTE VENT
E
EL ELEVATION
EMCS ENERGY MONOSERRAT
AND CENTRAL SYSTEM
EPA ENVIROMENTAL PROTECTION AGENCY
EPACT ENERGY POLICY ACT
ESC ESCUTCHEON
ESH EMERGENCY SHOWER
ET EXPANSION TANK
EWH ELECTRIC WATER HEATER
EWS EYE WASH STATION
EWS/SH EYE WASH/DRENCH SHOWER
EX EXISTING
F
F FAHRENHEIT
FCO FLOOR CLEANOUT
FCW FILTERED COLD WATER
FD FLOOR DRAIN
FDC FIRE DEPARTMENT (HOSE) CONNECTION
FM FLOW METER
FOP FUEL OIL PUMP
FOR FUEL OIL RETURN
FOS FUEL OIL SUPPLY
FOV FUEL OIL VENT
FS FLOOR SINK
FS FLOW SWITCH
FU FIXTURE UNITS
G
GAL GALLON
GCO GRADE CLEANOUTS
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GPR GAS PRESSURE REGULATOR
GRS GAS REGULATOR STATION
GT GREASE TRAP
GVTR GAS VENT THROUGH ROOF
GWH GAS FIRED WATER HEATER
H
H&CW HOT AND COLD WATER
HB HOSE BIBB
HD HUB DRAIN
HEX HEAT EXCHANGER
HP HORSEPOWER
HS HAND SINK
HST HOT WATER STORAGE TANK (DOMESTIC)
HWB HOT WATER BOILER
HWCP HOT WATER CIRCULATING PUMP
HWP HOT WATER PUMP
HYD HYDRANT
I
ID INSIDE DIAMETER
IE INVERT ELEVATION
ICW INDUSTRIAL COLD WATER
IHW INDUSTRIAL HOT WATER
INV INVERT
IPC INTERNATIONAL PLUMBING CODE
IRW IRRIGATION WATER
IW INDIRECT WASTE
IWH INSTANTANEOUS WATER HEATER
IWR INDUSTRIAL WATER RETURN
IWS INDUSTRIAL WATER SUPPLY
K
KW KILOWATT
KWH KILOWATT-HOUR
L
L/S LITER PER SECOND
LA LABORATORY AIR
LAV LAVATORY
LBS/HR POUNDS PER HOUR
LCW LABORATORY COLD WATER
LHW LABORATORY HOT WATER
LNG LIQUID NATURAL GAS
LOX LIQUID OXYGEN
LV LABORATORY VACUUM
LW LOW WATER
M
M METER
MA MEDICAL AIR
MAV MANUAL AIR VENT
MBH 1000 BTUH
MED MEDICAL
MER MECHANICAL EQUIPMENT
ROOM
MH MANHOLE
MOU MEMORANDUM OF
UNDERSTADING
MSB MOP SERVICE BASIN
MV MEDICAL VACUUM
N
N2 NITROGEN
N20 NITROUS OXIDE
NC NORMALLY CLOSED
NG NATURAL GAS
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NOM. NOMINAL
NPW NON POTABLE WATER
NTS NOT TO SCALE
O
O2 OXYGEN
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OR OPERATING ROOM
OVFL OVERFLOW
P
PA PASCAL
PD PRESSURE DROP OR DIFFERENCE
PDI PLUMBING AND DRAINAGE
INSTITUTE
PG PRESSURE GAGE
PP PLUMBING PUMP
PPM PARTS PER MILLION
PRS PRESSURE REDUCING STATION
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH
ATMOSPHERE
PSIG POUNDS PER SQUARE INCH
GAGE
PTRV PRESSURE TEMPERATURE RELIEF
VALVE
PW POTABLE WATER
R
RD ROOF DRAIN
RDL ROOF DRAIN LEADER
RL ROOF LEADER
RP RECIRCULATION PUMP
RO REVERSE OSMOSIS WATER
RWL RAIN WATER LEADER
S
SAN SANITARY SEWER
SMACNA SHEET METAL AND AIR
CONDITIONING CONTRACTORS
NATIONAL ASSOCIATION
SCFM STANDARD CUBIC FOOT/MINUTE
SCW SOFTENED COLD WATER
SDMH STORM DRAIN MANHOLE
SMH SANITARY MANHOLE
SP SUMP PUMP
SPR SPRINKLER LINE
SQFT/SF SQUARE FEET
SS STAINLESS STEEL
ST STORAGE TANK
SW STORM WATER
T
TCV TEMPERATURE CONTROL VALVE
TD TEMPERATURE DIFFERENCE
TD TRENCH DRAIN
TDH TOTAL DYNAMIC HEAD
TEMP TEMPERATURE
TMV THERMOSTATIC MIXING VALVE
TP TRAP PRIMER
TSTAT THERMOSTAT
TWR TEMPERED WATER RETURN
TWS TEMPERED WATER SUPPLY
TYP TYPICAL
V
V VENT
VAC VACUUM
VB VACUUM BREAKER
VCO VACUUM CLEANER OUTLET
VP VACUUM PUMP
VS VENT STACK
VSD VARIABLE SPEED DRIVE
VTR VENT THROUGH ROOF
W
W WASTE
WC WATER CLOSET
WCO WALL CLEANOUT
WG WATER GAGE
WH WALL HYDRANT
WH WATER HEATER
WHA WATER HAMMER ARRESTER
WL WATER LINE
WM WATER METER
WPD WATER PRESSURE DROP
WS WASTE STACK
WSFU WATER SUPPLY FIXTURE UNITS
Y
YCO YARD CLEANOUT
YH YARD HYDRANT
26-P 3
PIPING SYMBOLS
ANNOTATION
XX-1
xx
X100
X100
GENERAL PLUMBING SYMBOLS
DENTAL
MEDICAL GASES
STORM
FUEL
EXISTING PIPING
WATER
WASTE
VALVE SYMBOLS
GENERAL EQUIPMENT
FLOOR MOUNTED FLUSH VALVE WATER
CLOSET
WALL MOUNTED FLUSH VALVE WATER
CLOSET
ETR
ABBREVIATIONS
Drawing Number
Project Number
Date
Project Title
Building NumberLocation
Checked DrawnAPPROVED: CHIEF ENGINEER
Drawing Title
VA FORM
Office of Construction and Facilities Management
Dwg
CIVIL / STRUCTURAL ENGINEER M.E.P. / T. ENGINEER
APPROVED: DIRECTOR
APPROVED: ASSOCIATE DIRECTOR
APPROVED: ASSISTANT DIRECTOR APPROVED: CHIEF ENGINEER
REVISIONS DATE
CONSULTANTS ARCHITECT
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
A
1 2 3 4 5 6 7 8 9
B
C
D
E
F
A
B
C
D
E
F
H2B
1225 NORTH LOOP WEST, SUITE 900
HOUSTON, TX 77008
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
AZ ARCH REG. NO. 20013-0, EXP. 10/10/2019
AZ ENGR REG. NO. 20015-0, EXP. 10/10/2019 -OF- 148
RADIOLOGY EXPANSIONPLUMBING LEGEND
649-413
11/01/2018 JES RLC
107-P-000
100% CONSTRUCTION DOCUMENTS
DEPARTMENT OF VETERAN AFFAIRS
NORTHERN ARIZONA VA HEATH CARE SYSTEM
500 HWY 89N
PRESCOTT, AZ 86313
67EXPIRES 12/31/2019
1/2" MV
1/2" MA
3/4" G
H
W
H
W R
/2 C
W
1/2"
3/4"
3/4"
3/4" HWR TFA
1" HW TFA
2" CW TFA
3/4" MV TFA
3/4" MA TFA
1/2" G TFA
1/2" UTILITY AIR
2" 1"
3/4"
3/4" HW
3/4" CW
H
W
/2 C
W
H
W R
3/4" HWR
2 1/2" CW
/4
G
/2
M
A 1 /2
M
V
BB BB
AA AA
BID DEDUCT
ALTERNATE #1
3/4" G
3/4" G UP TO
ROOM 113
DENTAL LAB
/4
G
/4
H
W
/4
C
W
1/2" CW TFA
1/2" HW TFA
/4
C
W
3/4" CW TFA
1/2" HWR UP
1-1/4" HW UP
1-1/4" CW UP
1" HW TFA
2" CW TFA
3" S TFA
1/2" HWR TFA
1" HW TFA
1-1/4" CW TFA
1/2" HWR TFA
3/4" HW TFA
2" CW TFA
1/2" HWR TFA
1-1/4" HW TFA
1-1/4" CW TFA
1/2" CW UP
1/2" HWR UP
1-1/4" HW UP
1-1/4" CW UP
3/4" CW UP
1/2" HWR UP
1" HW UP
1" CW UP
2" CW UP
3/4" CW UP
3/4" CW
3/4" CW UP
BID DEDUCT
ALTERNATE #2
Drawing Number
Project Number
Date
Project Title
Building NumberLocation
Checked DrawnAPPROVED: CHIEF ENGINEER
Drawing Title
VA FORM
Office of Construction and Facilities Management
Dwg
CIVIL / STRUCTURAL ENGINEER M.E.P. / T. ENGINEER
APPROVED: DIRECTOR
APPROVED: ASSOCIATE DIRECTOR
APPROVED: ASSISTANT DIRECTOR APPROVED: CHIEF ENGINEER
REVISIONS DATE
CONSULTANTS ARCHITECT
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
A
1 2 3 4 5 6 7 8 9
B
C
D
E
F
A
B
C
D
E
F
H2B
1225 NORTH LOOP WEST, SUITE 900
HOUSTON, TX 77008
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
AZ ARCH REG. NO. 20013-0, EXP. 10/10/2019
AZ ENGR REG. NO. 20015-0, EXP. 10/10/2019 -OF- 148
RADIOLOGY EXPANSIONPLUMBING SUPPLY DEMOLITION
BASEMENT FLOOR PLAN
649-413
11/01/2018 JES RLC
107-PPD100
100% CONSTRUCTION DOCUMENTS
DEPARTMENT OF VETERAN AFFAIRS
NORTHERN ARIZONA VA HEATH CARE SYSTEM
500 HWY 89N
PRESCOTT, AZ 86313
1/8" = 1'-0"
PLUMBING SUPPLY DEMOLITION
BASEMENT FLOOR PLAN
PLUMBING SUPPLY DEMO PLAN NOTES:
1. REMOVE EXISTING FIXTURE AND ASSOCIATED DOMESTIC WATER SUPPLY PIPING
AND DEAD END BRANCHES BACK TO MAIN AS INDICATED. REMOVE TEE AND
PROVIDE TRANSITION COUPLING. SEE 107-PP101 FOR RELATED WORK.
2. EXISTING FIRE DEPARTMENT WATER CONNECTION. SEE SHEET FXD101.
3. 1/2” ABANDONED UTILITY AIR PIPING TO BE REMOVED. SEE SHEET 107-PPD101
FOR RELATED WORK.
4. FIELD VERIFY LOCATION OF EXISTING DEADLEGS AND DEMO BACK TO MAIN LINE.
REMOVE TEE AND PROVIDE TRANSITION COUPLING.
GENERAL NOTES:
1. THE AREA OF WORK SHOWN IS ASSOCIATED WITH AN OPERATING FACILITY THAT
MUST REMAIN IN SERVICE 24 HOURS A DAY, 7 DAYS A WEEK.
2. COORDINATE WORK SCHEDULE WITH THE CONTRACTING OFFICER'S
REPRESENTATIVE.
3. COORDINATE PLUMBING WORK WITH ALL OTHER TRADES. VERIFY ALL EXISTING
CONDITIONS BEFORE THE START OF WORK.
4. SEE SHEET GI001 FOR ADDITIONAL INFORMATION REGARDING SCHEDULE AND
PHASING REQUIREMENTS. SCHEDULE WORK IN THE EXISTING BUILDING TO
MINIMIZE DISRUPTION OF SERVICES.
N
BID DEDUCT ALTERNATE NOTES:
1. BID DEDUCT ALTERNATE #1: IF DEDUCT ALTERNATE IS CHOSEN, EXISTING
FIXTURES, ASSOCIATED PIPE, AND ACCESSORIES TO REMAIN. SEE 107-PP100 FOR
RELATED INFORMATION.
2. BID DEDUCT ALTERNATE #2: IF DEDUCT ALTERNATE IS CHOSEN, EXISTING
FIXTURES, ASSOCIATED PIPE, AND ACCESSORIES TO REMAIN. SEE 107-PP100 FOR
RELATED INFORMATION.
3. BID DEDUCT ALTERNATE #3: IF DEDUCT ALTERNATE IS CHOSEN, NO CHANGES
ARE NECESSARY. SEE 107-PP100 FOR RELATED INFORMATION.
3/4" HWR FFB
1" HW FFB
2" CW FFB
1/2" G FFB
1/2" UTILITY AIR FFB
/4
C
W
/4
C
W /4
H
W
/4
H
W
/4
H
W /4
C
W
2" CW
1" HW
1/2" CW
1/2" HW
3/4" HWR
BB BB
AA AA
1 1/4"
1"
1/2"
CW
HW
HWR
1/2" HW
1/2" CW
1/2" HWR
BID DEDUCT
ALTERNATE #1
1/2" HW TFA
1/2" CW TFA
3/4" G FFB
1/2" CW UP
1/2" HWR UP
1-1/4" HW UP
1-1/4" CW UP
3/4" CW UP
1/2" HWR TFA
1" HW TFA
1" CW TFA
1/2" HWR TFA
3/4" HW TFA
1-1/4" CW TFA
2" CW UP
3/4" CW FFB
3/4" CW FFB
3/4" CW FFB
BID DEDUCT
ALTERNATE #2
Drawing Number
Project Number
Date
Project Title
Building NumberLocation
Checked DrawnAPPROVED: CHIEF ENGINEER
Drawing Title
VA FORM
Office of Construction and Facilities Management
Dwg
CIVIL / STRUCTURAL ENGINEER M.E.P. / T. ENGINEER
APPROVED: DIRECTOR
APPROVED: ASSOCIATE DIRECTOR
APPROVED: ASSISTANT DIRECTOR APPROVED: CHIEF ENGINEER
REVISIONS DATE
CONSULTANTS ARCHITECT
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
A
1 2 3 4 5 6 7 8 9
B
C
D
E
F
A
B
C
D
E
F
H2B
1225 NORTH LOOP WEST, SUITE 900
HOUSTON, TX 77008
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
AZ ARCH REG. NO. 20013-0, EXP. 10/10/2019
AZ ENGR REG. NO. 20015-0, EXP. 10/10/2019 -OF- 148
RADIOLOGY EXPANSIONPLUMBING SUPPLY DEMOLITION
LEVEL 1 FLOOR PLAN
649-413
11/01/2018 JES RLC
107-PPD101
100% CONSTRUCTION DOCUMENTS
DEPARTMENT OF VETERAN AFFAIRS
NORTHERN ARIZONA VA HEATH CARE SYSTEM
500 HWY 89N
PRESCOTT, AZ 86313
1/8" = 1'-0"
PLUMBING SUPPLY DEMOLITION LEVEL
1 FLOOR PLAN
PLUMBING SUPPLY DEMO PLAN NOTES:
1. REMOVE EXISTING FIXTURE AND ASSOCIATED DOMESTIC WATER SUPPLY PIPING
AND DEAD END BRANCHES BACK TO MAIN AS INDICATED. REMOVE TEE AND
PROVIDE TRANSITION COUPLING. SEE 107-PP101 FOR RELATED WORK.
2. EXISTING FIRE DEPARTMENT WATER CONNECTION. SEE SHEET 107-FXD101 FOR
RELATED WORK.
3. 1/2” ABANDONED UTILITY AIR PIPING TO BE REMOVED. SEE SHEET 107-PPD100
FOR RELATED WORK.
4. EXISTING FIXTURES AND ASSOCIATED PIPING TO REMAIN.
5. DEMO PIPING BACK TO PENETRATION FROM FLOOR ABOVE. SEE 107-PP101 FOR
RELATED WORK.
GENERAL NOTES:
1. THE AREA OF WORK SHOWN IS ASSOCIATED WITH AN OPERATING FACILITY THAT
MUST REMAIN IN SERVICE 24 HOURS A DAY, 7 DAYS A WEEK.
2. COORDINATE WORK SCHEDULE WITH THE CONTRACTING OFFICER'S
REPRESENTATIVE.
3. COORDINATE PLUMBING WORK WITH ALL OTHER TRADES. VERIFY ALL EXISTING
CONDITIONS BEFORE THE START OF WORK.
4. SEE SHEET GI001 FOR ADDITIONAL INFORMATION REGARDING SCHEDULE AND
PHASING REQUIREMENTS. SCHEDULE WORK IN THE EXISTING BUILDING TO
MINIMIZE DISRUPTION OF SERVICES.
N
BID DEDUCT ALTERNATE NOTES:
1. BID DEDUCT ALTERNATE #1: IF DEDUCT ALTERNATE IS CHOSEN, EXISTING
FIXTURES, ASSOCIATED PIPE, AND ACCESSORIES TO REMAIN. SEE 107-PP101 FOR
RELATED INFORMATION.
2. BID DEDUCT ALTERNATE #2: IF DEDUCT ALTERNATE IS CHOSEN, EXISTING
FIXTURES, ASSOCIATED PIPE, AND ACCESSORIES TO REMAIN. SEE 107-PP101 FOR
RELATED INFORMATION.
3. BID DEDUCT ALTERNATE #3: IF DEDUCT ALTERNATE IS CHOSEN, NO CHANGES
ARE NECESSARY. SEE 107-PP101 FOR RELATED INFORMATION.
S
S
S 5 " S
S
BB BB
AA AA
BID DEDUCT
ALTERNATE #1
S T
S T
5" ST
5" ST
6" S 6" S 6" S 6" S
S
S
S
5" S
3" S4 S
T
5" ST
S
T
S
T
S
T
4" ST
S
T
S
T
4" ST5" ST
4" S
T
5" ST
4" ST DN FFA
4" ST DN FFA
5" S
T
4" ST DN FFA
4" ST DN FFA
3" S 6" S
5" S DN FFA
4" ST DN FFA
3" ST DN FFA
3" ST DN FFA
3" ST DN FFA
S
3" S DN FFA
3" S DN FFA
4" S DN FFA
3" S DN FFA
4" S DN FFA
2" S DN FFA
BID DEDUCT
ALTERNATE #2
Drawing Number
Project Number
Date
Project Title
Building NumberLocation
Checked DrawnAPPROVED: CHIEF ENGINEER
Drawing Title
VA FORM
Office of Construction and Facilities Management
Dwg
CIVIL / STRUCTURAL ENGINEER M.E.P. / T. ENGINEER
APPROVED: DIRECTOR
APPROVED: ASSOCIATE DIRECTOR
APPROVED: ASSISTANT DIRECTOR APPROVED: CHIEF ENGINEER
REVISIONS DATE
CONSULTANTS ARCHITECT
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
A
1 2 3 4 5 6 7 8 9
B
C
D
E
F
A
B
C
D
E
F
H2B
1225 NORTH LOOP WEST, SUITE 900
HOUSTON, TX 77008
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
AZ ARCH REG. NO. 20013-0, EXP. 10/10/2019
AZ ENGR REG. NO. 20015-0, EXP. 10/10/2019 -OF- 148
RADIOLOGY EXPANSIONPLUMBING WASTE DEMOLITION
LEVEL 1 FLOOR PLAN
649-413
11/01/2018 JES RLC
107-PLD101
100% CONSTRUCTION DOCUMENTS
DEPARTMENT OF VETERAN AFFAIRS
NORTHERN ARIZONA VA HEATH CARE SYSTEM
500 HWY 89N
PRESCOTT, AZ 86313
1/8" = 1'-0"
PLUMBING WASTE DEMOLITION LEVEL
1 FLOOR PLAN
PLUMBING WASTE DEMO PLAN NOTES:
1. EXISTING LABORATORY EXPANSION TO BE DEMOLISHED ALONG WITH ALL
SANITARY AND STORM PIPING TO DEMARCATION POINT SHOWN.
2. EXISTING BUILDING 107 SELECTIVE DEMOLITION. REMOVE PLUMBING FIXTURES
AND ASSOCIATED SANITARY WASTE AND VENT PIPING.
3. EXISTING BUILDING 107 STORM PIPING TO REMAIN UNLESS NOTED OTHERWISE.
4. REMOVE ANY SANITARY WASTE AND VENT PIPING WHERE LAVATORY HAS BEEN
PREVIOUSLY REMOVED. VERIFY DEAD END PIPING HAS BEEN REMOVED FROM
CRAWL SPACE AND BEHIND WALLS.
5. EXISTING FIXTURES TO REMAIN.
GENERAL NOTES:
1. THE AREA OF WORK SHOWN IS ASSOCIATED WITH AN OPERATING FACILITY THAT
MUST REMAIN IN SERVICE 24 HOURS A DAY, 7 DAYS A WEEK.
2. COORDINATE WORK SCHEDULE WITH THE CONTRACTING OFFICER'S
REPRESENTATIVE.
3. COORDINATE PLUMBING WORK WITH ALL OTHER TRADES. VERIFY ALL EXISTING
CONDITIONS BEFORE THE START OF WORK.
4. SEE SHEET GI001 FOR ADDITIONAL INFORMATION REGARDING SCHEDULE AND
PHASING REQUIREMENTS. SCHEDULE WORK IN THE EXISTING BUILDING TO
MINIMIZE DISRUPTION OF SERVICES.
N
BID DEDUCT ALTERNATE NOTES:
1. BID DEDUCT ALTERNATE #1: IF DEDUCT ALTERNATE IS CHOSEN, EXISTING PIPE,
ASSOCIATED FIXTURES, AND ACCESSORIES TO REMAIN. SEE 107-PL101 FOR
RELATED INFORMATION.
2. BID DEDUCT ALTERNATE #2: IF DEDUCT ALTERNATE IS CHOSEN, EXISTING PIPE,
ASSOCIATED FIXTURES, AND ACCESSORIES TO REMAIN. SEE 107-PL101 FOR
RELATED INFORMATION.
3. BID DEDUCT ALTERNATE #3: IF DEDUCT ALTERNATE IS CHOSEN, NO CHANGES
ARE NECESSARY. SEE 107-PL101 FOR RELATED INFORMATION.
BB BB
AA AA
2 2
BID DEDUCT
ALTERNATE #1
/2 O
X
3/4" MV
1/2" MA
1/2" OX
Drawing Number
Project Number
Date
Project Title
Building NumberLocation
Checked DrawnAPPROVED: CHIEF ENGINEER
Drawing Title
VA FORM
Office of Construction and Facilities Management
Dwg
CIVIL / STRUCTURAL ENGINEER M.E.P. / T. ENGINEER
APPROVED: DIRECTOR
APPROVED: ASSOCIATE DIRECTOR
APPROVED: ASSISTANT DIRECTOR APPROVED: CHIEF ENGINEER
REVISIONS DATE
CONSULTANTS ARCHITECT
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
A
1 2 3 4 5 6 7 8 9
B
C
D
E
F
A
B
C
D
E
F
H2B
1225 NORTH LOOP WEST, SUITE 900
HOUSTON, TX 77008
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
AZ ARCH REG. NO. 20013-0, EXP. 10/10/2019
AZ ENGR REG. NO. 20015-0, EXP. 10/10/2019 -OF- 148
RADIOLOGY EXPANSIONPLUMBING MEDICAL GAS
DEMOLITION LEVEL 1 FLOOR PLAN
649-413
11/01/2018 JES RLC
107-PJD101
100% CONSTRUCTION DOCUMENTS
DEPARTMENT OF VETERAN AFFAIRS
NORTHERN ARIZONA VA HEATH CARE SYSTEM
500 HWY 89N
PRESCOTT, AZ 86313
1/8" = 1'-0"
PLUMBING MEDICAL GAS DEMOLITION
LEVEL 1 FLOOR PLAN
N
GENERAL NOTES:
1. THE AREA OF WORK SHOWN IS ASSOCIATED WITH AN OPERATING FACILITY THAT
MUST REMAIN IN SERVICE 24 HOURS A DAY, 7 DAYS A WEEK.
2. COORDINATE WORK SCHEDULE WITH THE CONTRACTING OFFICER'S
REPRESENTATIVE.
3. COORDINATE PLUMBING WORK WITH ALL OTHER TRADES. VERIFY ALL EXISTING
CONDITIONS BEFORE THE START OF WORK.
4. SEE SHEET GI001 FOR ADDITIONAL INFORMATION REGARDING SCHEDULE AND
PHASING REQUIREMENTS. SCHEDULE WORK IN THE EXISTING BUILDING TO
MINIMIZE DISRUPTION OF SERVICES.
5. POSITIVE PRESSURE PATIENT MEDICAL GAS PIPING SHALL NOT BE BREACHED OR
PENETRATED BY ANY MEANS OR PROCESS THAT WILL RESULT IN RESIDUAL
COPPER PARTICLES OR OTHER DEBRIS REMAINING IN THE PIPING, OR THAT
AFFECTS THE OXYGEN-CLEAN INTERIOR OF THE PIPING. IF BREACHING OR
PENETRATING THE MEDICAL GAS PIPING IS REQUIRED, THE PROCESS SHALL
ENSURE THAT ANY DEBRIS CREATED BY THE PROCESS REMAINS CONTAINED
WITHIN THE WORK AREA.
6. ALL VALVES IN THE MEDICAL GAS SYSTEMS SHALL BE QUARTER TURN OFF WITH
INDICATION OF WHETHER THE VALVE IS OPEN OR CLOSED. A LABEL SHALL BE
PROVIDED ON ALL VALVES INDICATING THE TYPE OF SERVICE, THE AREA(S) OR
ROOM(S) SERVED, AND A WARNING THAT THE VALVE SHALL NOT BE OPENED OR
CLOSED EXCEPT FOR EMERGENCY SITUATIONS.
7. HOT TAPS OR SIMILAR VALVE ASSEMBLIES ARE NOT PERMITTED IN MEDICAL GAS
PIPING SYSTEMS.
8. EACH NEW FITTING, VALVE, AND LENGTH OF NEW MEDICAL GAS TUBING SHALL BE
CLEANED, CAPPED, AND SEALED BY THE MANUFACTURER UNTIL PREPARED FOR
INSTALLATION. ALL COMPONENTS SHALL BE CONSTRUCTED OF TYPE K COPPER.
9. IDENTIFY AREA ALARM(S) SHOWN WITH THE NAME OF THE MEDICAL GASES BEING
SERVED AND THE AREAS MONITORED BY THE ALARM PANEL.
10. STATION OUTLET / INLET ASSEMBLIES MUST BE SELECTED SUCH THAT GAS-
SPECIFIC COMPONENTS CANNOT BE INTERCHANGED BETWEEN THE STATION
OUTLET / INLET FOR DIFFERENT GASES.
11. ALL NEW MEDICAL GAS BRANCH PIPING TO ROOM OUTLET / INLET ASSEMBLIES IS
3/4” UNLESS NOTED OTHERWISE. 1/2” BRANCH PIPING TO INDIVIDUAL OUTLETS /
INLETS IS PERMITTED.
MEDICAL GAS DEMO PLAN NOTES:
1. REMOVE EXISTING OUTLETS AND ASSOCIATED MEDICAL GAS PIPING BACK TO
MAIN IN CRAWL SPACE. SEE NEW WORK FOR RELATED SCOPE.
2. REMOVE EXISTING OUTLETS AND ASSOCIATED MEDICAL GAS PIPING BACK TO
RISER IN SEISMIC CHASE AND CAP.
3. FIELD VERIFY MEDICAL GAS PIPE ROUTING AND REMOVE EXISTING OUTLETS AND
PIPING BACK TO RISER IN SEISMIC CHASE AND CAP.
4. BID DEDUCT ALTERNATE #1 DEMARCATION POINT.
BID DEDUCT ALTERNATE NOTES:
1. BID DEDUCT ALTERNATE #1: IF DEDUCT ALTERNATE IS CHOSEN, EXISTING PIPE
AND ASSOCIATED ACCESSORIES TO REMAIN. EXCEPTION – EXISTING PIPE
ROUTED TO BUILDING 117 TO BE REMOVED TO DEMARCATION POINT SHOWN.
SEE 107-PJ101 FOR RELATED INFORMATION.
2. BID DEDUCT ALTERNATE #2: IF DEDUCT ALTERNATE IS CHOSEN, NO CHANGES
ARE NECESSARY. SEE 107-PJ101 FOR RELATED INFORMATION.
3. BID DEDUCT ALTERNATE #3: IF DEDUCT ALTERNATE IS CHOSEN, NO CHANGES
ARE NECESSARY. SEE 107-PJ101 FOR RELATED INFORMATION.
1.1
1.1 3 4 6 9 10
CC
DD
EE
FF
/2 C
W
H
W R
H
W
2 1/2" CW
1 1/2" HW
3/4" G
3/4" G
2 1/2" CW
2" HW
2" CW3/4" CW
3/4" HW
CT SCANNER EQUIP. RM
P-708
P-804
P-804
3/4" HWR
1 1/2" HW
2 1/2" CW
1 1/2" HW
1" HWR
/2
H
W R
/4
H
W
3/4" HW2 1/2" CW
/2
C
W
1/2" CW
/2
C
W
1/2" CW
/2
C
W
1/2" CWR
H W
R
/2
H
W
/2
C
W
/2
C
W
/2
H
W
H
W R
/2
H W
2 1/2" CW
/2
C W
/2 C
W
1 1/2" HW
1 1/2" HW
/2
C W
/2
H W
2 1/2" CW
3/4" HW
1/2" HWR
1 1/2" HW
1/2" CW
1/2" CW
1 1/2" CW
3/4" HW
3/4" CW
3/4" CW
/4
C
W
3/4" CW
/4
H
W
3/4" HW
1/2" HWR
1/2" CW
1/2" HWR
1/2" HW
1/2" CW
1/2" HW
1" CW
1" HW
1/2" HWR
1/2" HW 1/2" CW
1" CW
1" HW
3/4" HW3/4" CW
1/2" HW
1/2" CW
3/4" CW
3/4" CW
1/2" CW
1" CW
1" HW
1" CW
1" HW
1" CW
1" HW
1/2" HWR
1 1/2" CW
1/2" HWR
1" HW
1/2" HWR
3/4" HW
1 1/2" CW
1/2" HWR
1/2" HW
1/2" CW
1/2" HW
1 1/2" CW
1 1/4" CW
1/2" CW3/4" CW
3/4" CW
3/4" HW
1 1/2" HW
1 1/2" CW
1/2" HW
1/2" HWR
1/2" HWR
1/2" CW
1/2" HW
1" HWR
2 1/2" CW
1/2" CW
1/2" CW
1/2" HW
1 1/2" CW
/2
C W
3/4" CW
1/2" CW
1/2" HW
1/2" HWR
3/4" CW
1 1/2" CW
1 1/2" CW
1 1/2" CW
2 1/2" CW
2 1/2" CW
1" HW
1" HW
1" CW
3/4" G
1/2" HW
3/4" HWR1/2" HWR
1" HWR
1 1/4" CW
1" HW
1/2" HWR
1/2" HWR
1 1/4" HW
2" CW
3/4" CW
3/4" HW
E.1E.1
F.1F.1
G
1 2.1 4.5 7 8.1
A.5
A.1 A.1
A A
B B
A.2
B.1
C.1
D.2
D.1
B.9
C.2
B.2
1.5
2.9
RP-4
P-804
H W
R
1/2" HW
1/2" HW
3/4" HW
1" HWR
1" HWR
/2 H
W
/2 H
W
CONNECT TO EXISTING HOT WATER HEATER "A".
INSTALL TMV-2 AT CONNECTION.
SEE DETAILS 1 & 2 ON 107-P-302.
BFP-1
/2
C
W
1/2" CW
/2
C
W
1/2" CW
BID DEDUCT
ALTERNATE #2
BID DEDUCT
ALTERNATE #1
BID DEDUCT
ALTERNATE #3
BID DEDUCT
ALTERNATE #3HU
HU
HU
3/4" G UP TO
ROOM 113
DENTAL LAB
1/2" CW TFA
1/2" HW TFA
3/4" CW TFA
3/4" CW UP
1/2" HWR UP
1" HW UP
1" CW UP
Drawing Number
Project Number
Date
Project Title
Building NumberLocation
Checked DrawnAPPROVED: CHIEF ENGINEER
Drawing Title
VA FORM
Office of Construction and Facilities Management
Dwg
CIVIL / STRUCTURAL ENGINEER M.E.P. / T. ENGINEER
APPROVED: DIRECTOR
APPROVED: ASSOCIATE DIRECTOR
APPROVED: ASSISTANT DIRECTOR APPROVED: CHIEF ENGINEER
REVISIONS DATE
CONSULTANTS ARCHITECT
o n e -e ig h th i n c h o n e f o o t o n e -q u a rt e r in c h o n e f o o t th re e -e ig h th s i n c h o n e f o o t o n e -h a lf i n c h o n e f o o t th re e -q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e -h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
A
1 2 3 4 5 6 7 8 9
B
C
D
E
F
A
B
C
D
E
F
H2B
1225 NORTH LOOP WEST, SUITE 900
HOUSTON, TX 77008
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
AZ ARCH REG. NO. 20013-0, EXP. 10/10/2019
AZ ENGR REG. NO. 20015-0, EXP. 10/10/2019 -OF- 148
RADIOLOGY EXPANSIONPLUMBING SUPPLY BASEMENT
FLOOR PLAN
649-413
11/01/2018 JES RLC
107-PP100
100% CONSTRUCTION DOCUMENTS
DEPARTMENT OF VETERAN AFFAIRS
NORTHERN ARIZONA VA HEATH CARE SYSTEM
500 HWY 89N
PRESCOTT, AZ 86313
1/8" = 1'-0"
PLUMBING SUPPLY BASEMENT FLOOR
PLAN N
GENERAL NOTES:
1. THE AREA OF WORK SHOWN IS ASSOCIATED WITH AN OPERATING FACILITY THAT
MUST REMAIN IN SERVICE 24 HOURS A DAY, 7 DAYS A WEEK.
2. COORDINATE WORK SCHEDULE WITH THE CONTRACTING OFFICER'S
REPRESENTATIVE.
3. COORDINATE PLUMBING WORK WITH ALL OTHER TRADES. VERIFY ALL EXISTING
CONDITIONS BEFORE THE START OF WORK.
4. SEE SHEET GI001 FOR ADDITIONAL INFORMATION REGARDING SCHEDULE AND
PHASING REQUIREMENTS. SCHEDULE WORK IN THE EXISTING BUILDING TO
MINIMIZE DISRUPTION OF SERVICES.
PLUMBING SUPPLY PLAN NOTES:
1. PROVIDE DRAIN VALVE ON RISERS.
2. PROVIDE DOMESTIC WATER CONNECTION TO HUMIDIFIER. PROVIDE 5 MICRON
MILTER ON SUPPLY LINE. SEE MECHANICAL DETAIL 9/107-M-502 FOR RELATED
INFORMATION.
3. INSTALL DOMESTIC WATER PIPING AND CONNECT TO EXISTING PIPING AS
SHOWN.
BID DEDUCT ALTERNATE NOTES:
1. BID DEDUCT ALTERNATE #1: IF DEDUCT ALTERNATE IS CHOSEN, STUB OUT LINE
FOR FUTURE CONNECTION AND PROVIDE TEE, VALVE, AND CAP AS CLOSE TO
MAIN AS POSSIBLE. SEE 107-PPD100 FOR RELATED INFORMATION.
2. BID DEDUCT ALTERNATE #2: IF DEDUCT ALTERNATE IS CHOSEN, STUB OUT LINE
FOR FUTURE CONNECTION AND PROVIDE TEE, VALVE, AND CAP AS CLOSE TO
MAIN AS POSSIBLE. SEE 107-PPD100 FOR RELATED INFORMATION.
3. BID DEDUCT ALTERNATE #3: IF DEDUCT ALTERNATE IS CHOSEN, OMIT
HUMIDIFIERS AND ASSOCIATED PIPING. SEE MECHANICAL PLANS FOR RELATED
INFORMATION. STUB OUT LINE FOR FUTURE CONNECTION AND PROVIDE TEE,
VALVE, AND CAP AS CLOSE TO MAIN AS POSSIBLE. SEE 107-PPD100 FOR RELATED
INFORMATION.
1.1 3 4 6 9 10
CC
DD
EE
FF
P-414
?P-103
P-701
P-414
P-103
P-414
P-414
P-414
P-414
P-414
P-414
P-414
P-414
P-414P-414
P-414
P-414 P-414
P-414
P-103
P-103
P-103
P-103
P-103
P-103
P-103
P-103
P-414
P-502
ENTRY VESTIBULE
NEW ELEC.
WOMEN'S TOILET
STORAGE
INPATIENT HOLDING
INPATIENT HOLDING
STORAGE
EQUIP. ALCOVE
COMMS
STAFF TOILET
118 PHYS. VIEWING ROOM
PHYS. VIEWING ROOM
PHYS. VIEWING ROOM
PACS
ON-CALL ROOM
MEETING ROOM
SUPERVISOR
120B
WORK AREA
CHIEF TECHNOLOGIST
120A
STAFF LOUNGE/TRAINING
HAC
TOILET
111A
ULTRASOUND
ULTRASOUND
WORKROOM
RECEPTION
105A
WAITING
SCHEDULING
DRESS
DRESS
MEN'S RESTROOM
WOMEN'S RESTROOM
DRESS
DRESS
FLUOROSCOPY X-RAY ROOM
ALCOVE
TOILET
135A
STAIRWELL
CT SCAN ROOM
CT CONTROL
SPECT CT SCAN ROOM
X-RAY
X-RAY
STRESS
NURSE
SOILED UTILITY
RESTROOM
PATIENT DOSE ADMINISTRATION
NM "HOT LAB" RADIOPHARMACY
144A
BONE DENSITOMETRY
MRI PREP/HOLDING
146A
MRI CONTROL ROOM
146B
MRI SCAN ROOM
146C
MRI SUB-WAITING
MRI ACCS.
146DMRI EQUIP. ROOM
MRI DRESS
146F
MRI DRESS
146E
RADIO DROP-OFF
144B
P-801
P-801
P-801
P-608
P-608
P-528
P-528
P-528
?P-708
P-708
P-708
P-524
?P-528
P-608
/4
C
W1 1/2" CW
1/2" HW
1/2" HWR
1" HW
1 1/4" CW
1/2" CW
1/2" HW
1 1/4" CW
1/2" HWR
3/4" HW
2" CW
1 1/2" CW
2" CW
2" CW
1/2" HWR 1 1/4" HW
1 1/4" CW 3/4" CW
1/2" CW
1 1/2" CW
3/4" CW
E.1E.1
F.1F.1
G
1 2.1 4.5 7 8.1
A.5
A.1 A.1
A A
B B
A.2
B.1
C.1
D.2
D.1
B.9
C.2
B.2
1.5
2.9
3/4" HW
1/2" CW
1/2" CW 1/2" HW
1/2" HW
1/2" CW
1/2" HW
1/2" HW
1/2" CW
1/2" CW
1/2" HW
1/2" HW
1/2" CW
1/2" CW
1/2" HW
1/2" HW
1/2" CW
P-528
1/2" CW
3/4" HW
3/4" CW
1/2" CW 1/2" HW
1/2" HW
1/2" CW
3/4" HW
1/2" CW
1/2" HW
1/2" CW
1/2" HW
3/4" CW
3/4" HW
3/4" CW
3/4" HW
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1/2" HW
1/2" CW
BID DEDUCT
ALTERNATE #2
BID DEDUCT
ALTERNATE #1
BID DEDUCT
ALTERNATE #3
3/4" G FFB
3/4" CW FFB
3/4" CW FFB
3/4" UP TFA
1/2" HWR TFA
1" HW TFA
1" CW TFA
Drawing…