This addendum provides modifications and additions to construction documents for the Radiology Expansion project at the Northern Arizona VA Medical Center in Prescott, Arizona. The scope of work includes demolishing an existing lab expansion of approximately 3,000 square feet and constructing a new optimized footprint for the radiology department with centralized waiting room, wide hallways, and sufficiently sized rooms. The new construction and renovation are also to provide ground level access throughout the radiology department, future capacity for a second story addition accessible from an adjacent building, and structural and utility provisions for an elevator and access stairs.
The Department of Veterans Affairs intends to solicit fixed-price bids for the project utilizing design-bid-build procedures. The solicitation will be set aside for Service-Disabled Veteran-Owned Small Businesses and issued on or around August 8, 2019 via the Federal Business Opportunities website. The period of performance is approximately 425 calendar days from notice to proceed. The magnitude of construction is estimated between $5-10 million. All questions must be submitted in writing by the specified due date.
36E77619B0012 0004 649-413_Radiology Expansion Addendum 001.pdf
View the file
Other files
Show 40 more
Latest 50 of 59 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
September 11, 2019 ADDENDUM NO. 001
A 320 NW 10th Street, Suite A, Oklahoma City, OK 73103 P 405.842.6100 E design@spur-design.com W spur-design.com
PROJECT: Radiology Expansion PROJECT #: 649-613 / SPUR 1395.24
Northern Arizona VA Health Care System
Prescott, AZ
OWNER: Dept of Veterans Affairs
THE FOLLOWING MODIFICATIONS, ADDITIONS, AND DELETIONS ARE HEREBY MADE A PART OF THE CONTRACT DOCUMENTS.
ADDENDUM PROJECT MANUAL ITEMS:
Attached Supplemental Information:
1. Soil Report – add to Project Manual
2. Product Data-Basis of Design 3Form varia ecoresin – add to Project Manual
3. Product Data-Basis of Design Stonhard Stonerez RTZ - add to Project Manual
4. Detail for Knock-out - add to Project Manual
5. Signage Details - add to Project Manual
6. Structural Detail – add to Project Manual
Attached Specifications:
7. Specification Section 04 05 13 Masonry Mortaring – add to Specifications
8. Specification Section 04 05 16 Masonry Grouting - add to Specifications
9. Specification Section 04 20 00 Unit Masonry - add to Specifications
10. Specification Section 04 72 00 Cast Stone Masonry - add to Specifications
11. Specification Section 07 27 26 Fluid Applied Air Barriers, Vapor Permeable - add to Specifications
12. Specification Section 12 32 00 Manufactured Wood Casework - add to Specifications
13. Specification Section 13 49 16 Radio Frequency and Magnetic Sheilding for RFI – replace existing section
13 49 16 with this revised section.
Attached Construction Drawings:
14. 107-SS-001 Structural Details-Replace existing sheet 107-SS-001 with this revised sheet 107-SS-001.
15. 107-SS-100 Foundation Plan-Replace existing sheet 107-SS-100 with this revised sheet 107-SS-100.
16. 107-SS-201 Foundation Details-Replace existing sheet 107-SS-201 with this revised sheet 107-SS-201.
17. 107-AS-411 Interior Elevations II-Replace existing sheet 107-AS-411 with this revised sheet 107-AS-411.
18. 107-AS-701 Finish Floor Plan and Signage-Replace existing sheet 107-AS-701 with this revised sheet 107-
AS-701.
END OF ADDENDUM NO. 001
1FEBRUARY 15 2019 | MATSPEC - VARIA | REV 034
FEATURES AND BENEFITS
• Produced on an individual order basis, allowing for creative design and product selection (minimum order quantity – ONE sheet!)
• Heat-formable into virtually any shape or size for eye-catching installations
• SCS-certified recycled content helps achieve LEED® credits for building sustainability
• Very tough, allowing for easy fabrication and maximum installed durability
• Extremely versatile which enables designers to achieve full design potential
• Lightweight, half the density of glass, which makes for easier installation and reduces structural support requirements
• Excellent chemical resistance which reduces potential harm incurred by cleaning agents
• Varia Ecoresin is GREENGUARD Indoor Air Quality Certified
• Varia Ecoresin is Underwriters Laboratories registered
AVAILABLE INTERLAYERS AND COLORS
Varia Ecoresin is available in a variety of standard interlayer and color options. Visit 3-form.com for all available options.
TEXTURES AND FINISHES
Each product in the Varia Ecoresin collection comes standard with both a front and back finish. Additionally, 3form provides the option of substituting between standard finishes. In most cases, you can even pick diff erent front and back finishes.
Finishes include:
• Grain - Refined organic detail in a translucent wood grain finish.The pattern direction runs parallel to the eight foot side of the panel.
• Grid - Fine, horizontal crosshatched lines create a subtle texture.
• Patent - A high gloss finish with highest light transmittance
• Patina - A non-glare finish with smooth appearance
Product Description
3form Varia Ecoresin is a dynamic interlayer system with design possibilities as diverse as your imagination. By al-lowing you to custom-select the color, pattern, texture, interlayer and finish of your material, Varia Ecoresin trans-forms into the perfect medium for your architectural application.
An award-winning 3form product, Varia Ecoresin has the added benefit of being made from a specially-formulated co-polyester resin that combines performance with environmental responsibility. Ecoresin incorporates 40% pre-consumer recycled content without compromising aesthetics or overall physical properties, is compatible with one of the largest post-consumer recycle streams, and is GREENGUARD® Indoor Air Quality Certified.
• Sandstone - A more durable finish with a subtle texture
• Stucco - A durable finish with a pebbled texture
• Supermatte - A frosted matte finish for maximum light diffusion
• Vellum - A random brushed matte finish similar to the 3form renewable matte finish.
• Velvet - Durable blurred finish with a crushed velvet appearance.
The pattern direction runs parallel to the four foot side of the panel.
Additionally 3form low-VOC functional coatings may be applied to the surface of 3form Varia Ecoresin. Finishes include:
• Patina Plus - Non-glare finish with slightly frosted appearance
• SFX Frost - Applied frosted finish with paper-like appearance
• Writeable - Applied finish for markerboard application
PANEL SIZES AND TOLERANCES
Varia Ecoresin panels are offered in 4' x 8' (1.2 m x 2.4 m) and 4' x 10' (1.2 m x 3 m). All dimensions and squareness are subject to a 3/16" (4.7 mm) tolerance. 5' x 10' (1.5 m x 3 m) is also available, though some restrictions apply.
Varia Ecoresin is available in gauges from 1/16 inch to 1 inch.
NOMINAL MINIMUM MAXIMUM
THICKNESS ALLOWANCE ALLOWANCE
GAUGE GAUGE GAUGE
1/8" (3.1 mm) 0.098” 0.138”
3/16" (4.7 mm) 0.155” 0.205”
1/4" (6.3 mm) 0.196” 0.306”
3/8" (9.5 mm)* 0.304” 0.434”
1/2" (12.7 mm) 0.412” 0.562”
3/4" (19.0 mm) 0.618” 0.798”
1.0" (25.4 mm) 0.850” 1.090”
*Add +/- 1/32” (+/-0.8 mm) to the above tolerance for hint textured sheets.
**Add +/- 3/16” (+/-4.7 mm) to the above tolerance for all embossed texture sheets.
x varia ecoresin®
[Tiger Thatch]
2FEBRUARY 15 2019 | MATSPEC - VARIA | REV 034
Sheet tolerance readings are based on an average of several mea-surements along both long edges of each panel. These measure-ments are taken 2-3 inches (50-75 mm) from the edges of the panel.
PATTERN SKEW TOLERANCE
Linear patterns in Varia Ecoresin panels have a skew tolerance of 1/4" skew over 48”. Panels containing a pattern (Capiz, Timber, etc.) will not match up from sheet to sheet. If the sheets are intended to match, they should be field cut on-site to a smaller final sheet dimen-sion. HiRes panels will have an alignment tolerance of 1/4” from sheet to sheet.
FLATNESS TOLERANCE
Varia Ecoresin panels shall not have distortion in the form of a wrin-kle, twist or scallop along the perimeter of the sheet. Overall warp extending across the sheet is permitted to a maximum of 9/32" (7.14
mm) for each 48" (1.2 m) or fraction thereof. Panel is to be measured when laying horizontally under its own weight on a flat continuous surface.
Specifications
FLAMMABILITY & SMOKE TEST RESULTS –
BUILDING CODE APPROVALS
Varia Ecoresin has been independently tested and meet the criteria for approved interior finishes and light transmitting resin materials as described in the 2016 International Building Code®.
TEST 3FORM VARIA ECORESIN RESULT
ASTM D 2843 Smoke Density 71.6% PASS Less than 75
ASTM D 635 Flame Spread Self extinguishing PASS CC1
ASTM D 1929 Self-ignition Temperature
716°F PASS Greater than 650°F
UL94 Flame Class - HB PASS
UPITT Mortality Test PASS Not more toxic than wood
NFPA 286
1/4" thickness + below (walls only or ceilings only) 3/8" thickness + below (walls in standoff configuration or ceilings only)
Pass
Pass
Pass
Pass
The NFPA 286 corner burn test is accepted by the 2012 IBC for interior finishes. Passing the NFPA 286 test allows for materials to be utilized where Class A materials are required (IBC 803.1.2).
ASTM E84
Flame Spread, 1/8" thickness Smoke generated
Class A: 0-25 <450
ASTM E84
Flame Spread, 3/16" thickness Smoke generated
Class A: 0-25 <450
ASTM E84
Flame Spread, 1/4" thickness Smoke generated
Class B: 26-75 <450
ASTM E84
Flame Spread, 1/2" thickness Smoke generated
Class B: 26-75 <450
ASTM E84
Flame Spread, 3/4" thickness Smoke generated
Class B: 26-75 <450
ASTM E84
Flame Spread, 1" thickness Smoke generated
Class A: 0-25 <450
Due to their specialty construction, 3from Dichroic, Reflect and 3form Wood have their own unique set of fire performance results.
TEST 3FORM DICHROIC/REFLECT RESULT
ASTM D 2843 Smoke Density 47.5% PASS Less than 75
ASTM D 635 Flame Spread 17.4 mm/min PASS CC2
ASTM D 1929 Self-ignition Temperature
716°F PASS Greater than 650°F
ASTM E84
Flame Spread, 1/4" thickness Smoke generated
Class B: 26-75 <450
TEST 3FORM TIMBER RESULT
ASTM E84-03
Flame Spread, 3/8" thickness Smoke generated
Class B: 26-75 <450
PANEL WEIGHT
THICKNESS (INCHES) WEIGHT FLUX (LB/FT2)
1/16" (1.5 mm) 0.4 lb/ft2 (2.0 kg/m2) 1/8" (3.1 mm) 0.8 lb/ft2 (3.9 kg/m2) 3/16" (4.7 mm) 1.2 lb/ft2 (5.9 kg/m2) 1/4" (6.3 mm) 1.7 lb/ft2 (8.3 kg/m2) 3/8" (9.5 mm) 2.5 lb/ft2 (12.2 kg/m2) 1/2" (12.7 mm) 3.3 lb/ft2 (16.1 kg/m2) 3/4" (19.0 mm) 5.0 lb/ft2 (24.4 kg/m2) 1.0" (25.4 mm) 6.6 lb/ft2 (32.2 kg/m2)
EXPANSION/CONTRACTION ALLOWANCES
Like all resin products, 3form Varia Ecoresin will expand and contract nominally with fluctuations in temperature. The following formula provides allowances that should be made in framed or fitted applica-tions:
• Longest length of panel (inches) x temperature change of the sheet (°F) x 0.00004 = Amount of Linear Expansion/ Contraction (inches)
EXAMPLE:
• 48" x 96" panel experiencing 50°F temperature change will expand/ contract: 96 inches x 50 degrees x 0.00004 in/in ºF = 0.192 inches Installers should take extra precautions if installation is occurring before the HVAC systems are operational. Allowances should also be made in the following situations:
• Fastening points
• Channel depths in frames
• Holes for standoffs and other hardware
• Meeting points for multiple sheets of 3form Varia Ecoresin
USAGE LIMITATIONS
DO NOT use cyanoacrylate or solvent type thread locking materials with Varia Ecoresin. To more permanently secure hardware, use the recommended products from the 3form adhesives matrix.”
REFLECT
When using Varia Reflect in pressure fitting applications, such as stand-off supports, use a pressure distribution plate or neoprene gasket to prevent localized panel separations.
Varia Reflect cannot be heat formed.
DICHROIC
3form Dichroic has an inherent linerarity running parallel to the panel length. The 3form Dichoic interlayer is very delicate, it is not recom-mended for use in exterior applications.
DO NOT cut Dichroic with a jigsaw, scroll saw, or waterjet.
When using Dichroic in pressure fitting applications, such as stand-off supports, use a pressure distribution plate or neoprene gasket to prevent localized panel separations.
3FEBRUARY 15 2019 | MATSPEC - VARIA | REV 034
NATURALS
Varia Ecoresin Panels utilizing natural or organic materials (ie. leaves, branches or twigs) may change in appearance over time. Natural materials are also subject to inherent inconsistency in color, texture and shape. Small areas of delamination are also to be expected, especially near saw cut edges.
METALLICS
Varia Ecoresin panels utilizing metallic interlayers (ie. Hollywood, Electra, Itemba, Mirror print) may change in appearance over time due to antiquing of the metallic materials.
TIMBER
Because 3form Timber is produced from engineered wood products, it is not recommended for use in high moisture or exterior applica-tions. Wood products are very responsive to environmental condi-tions (moisture, humidity, temperature changes) and therefore is re-stricted to interior applications. Wood pieces in Timber may contain knots, imperfections, dark spots, stains and color variation.
After trimming, the following treatments improve the edge aesthet-ics.
Natural: Sand edges with 220 grit sandpaper and carefully wipe the edges with Weld-On 3 (or MEK) making sure not to get any of the chemical on the face or back of the sheet.
Mocha: Sand edges with 220 grit sandpaper and carefully wipe the edges with Minwax Special Walnut 224 stain.
OTHER
Birch will sometimes bleed and cause small amounts of yellowing while being manufactured. In addition, due to the manufacturing press process, birch bulbs may be dispersed within the sheet, some of which will be trapped in clear areas for the Birch Grove pattern.
Structured Bamboo is a one-sided product.
FABRICATION
Do not drill or fasten the Varia Ecoresin within 2x thickness of panel edge. See the 3form Varia Fabrication Manual for more detailed guidelines and instructions on cutting, drilling, routing, etc. of Varia Ecoresin panels.
EDGE SEALING
Certain Varia Ecoresin designed layers (organics, papers and fabrics in particular) can have a tendency to wick moisture over time if the edges become wet and are not adequately sealed. These Varia Ecoresin products should not be exposed to water or wet conditions without first applying an approved edge sealing treatment. Varia Ecoresin produced using C3 or HighRes do not require edge sealing.
These are good options to use as an alternative to Woven Colors and Organics. Edge sealing is required on all exposed edges (including any holes that are created to allow for stand-off fastening). There are some designed Varia Ecoresin Woven Colors that do not exhibit wicking behavior and therefore do not need to be edge sealed. If you have additional questions or concerns regarding edge sealing of 3form products please contact 3form.
DEFLECTION
3form Varia Ecoresin will exhibit different amounts of deflection given a variety of factors: fastening techniques, loads, gauges and panel dimensions to list a few. 3form can assist you with general deflection guidelines for your application. You may also consult the Varia Deflection Charts technical white paper. If your application has specific engineering requirements, please contact 3form for ad-ditional direction.
HEAT FORMING/COLD BENDING
Varia Ecoresin can be cold bent for simple bends and curved areas.
As a general rule, a minimum radius of 100 times thickness is ac-ceptable for Varia Ecoresin (will depend on interlayer material). A minimum radius of 250 times thickness should be used for Dichroic.
A minimum radius of 200 times thickness should be used for Timber (with the bending axis parallel to the wood slats).
Heat formed Dichroic panels will have a finished size 6” less on each dimension than the standard size sold.
STANDARD SIZE SIZE AFTER FORMING
48” x 96” 42” x 90” 48” x 120” 42” x 116”
PANEL THICKNESS
MINIMUM COLD BEND RADII
VARIA ECORESIN DICHROIC/REFLECT WOOD
1/16" (1.5 mm) 7" (178 mm) - -
1/8" (3.1 mm) 12" (305 mm) 32" (813 mm) 24" (610 mm)
3/16" (4.7 mm) 19" (483 mm) 47" (1194 mm) 37" (950 mm)
1/4" (6.3 mm) 25" (635 mm) 63" (1600 mm) 50" (1270 mm)
3/8" (9.5 mm) 37" (940 mm) 94" (2388 mm) 75" (1905 mm)
1/2" (12.7 mm) 50" (1270 mm) 125" (3175 mm) 100" (2540 mm)
3/4" (19.0 mm) 75" (1905 mm) 188" (4775 mm) 150" (3810 mm)
1" (25.4 mm) 100" (2540 mm) 250" (6350 mm) 200" (5080 mm)
Because of its low thermoforming temperature, Varia Ecoresin is easy to line bend or drape form. For specific details on line bending and heatforming please consult the 3form Varia Ecoresin Fabrication Manual.
The special construction of 3form Dichroic and Wood introduces challenges in terms of heat forming. Because both are rigid interlay-ers, complex curvature is not possible. Simple curves and bends may be accomplished.Timber can only be heat-formed in simple curves, perpendicular to the direction of the wood. Minimum heat forming radius for Timber is 48”.
For highly complex shapes and curves, consult with or employ the services of the experts in 3form Fabrication.
EDGE FINISHING
Edges of 3form Varia Ecoresin panels are able to be machined or routed into a variety of different forms. In addition to a straight edge, edges may accept beveling, rounding, etc. Additional finishing, such as sanding or polishing, can also be provided to some edges.
4FEBRUARY 15 2019 | MATSPEC - VARIA | REV 034
REFINISHING
It is possible for Varia Ecoresin to become damaged by scratching.
Patent is the only Varia Ecoresin finish that may be repaired, and requires use of a flame polishing technique.
Light scratches and scuffs on the sandstone surface finish can be repaired with a plastic polish. The majority of 3form products have a surface finish that would be ruined by buffing.
SOUND TRANSMISSION CLASS (STC) VALUES FOR VARIA ECORESIN
Measurement protocol: ASTM E 90 - Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements
THICKNESS STC VALUES
1/8" (3.1 mm) 25
3/16" (4.7 mm) 29
1/4" (6.3 mm) 31
3/8" (9.5 mm) 34
1/2" (12.7 mm) 34
1" (25.4 mm) 39
THERMAL INSULATION VALUES FOR VARIA ECORESIN
Insulative values are a function of both the convective properties (U-values and shading coefficients) and the conductive properties (thermal conductivity).
Measurement protocol: ASTM E 903 - Standard Test Method for Solar Absorbance, Reflectance and Transmittance of Materials Using Integrating Spheres. ASTM E 891-87 - Tables for Terrestrial Direct Normal Solar Spectral Irradiance Tables for Air Mass. ASTM E 408-71
- Standard Test Method for Total Normal Emittance of Surfaces Using Inspection-Meter Techniques.
VARIA ECORESIN CLEAR
THICKNESS
WINTER U-VALUE
(BTU/HR-FT2-°F)
SUMMER U-VALUE
(BTU/HR-FT2-°F)
1/4" (6.3 mm) 0.97 0.93
3/8" (9.5 mm) 0.90 0.87
1/2" (12.7 mm) 0.83 0.80
Chemical Resistance of 3form Varia Ecoresin to Select Compounds
365 DAY FULL IMMERSION TESTING @ 73ºF (23ºC)
Polymer materials are affected by chemicals in different ways.
Changes in performance or appearance can be attributed to fab-rication methods, exposure conditions, concentration of chemical substances or exposure duration. Such factors can even influence the final effect of substances that 3form Varia Ecoresin is considered "Resistant" to under test conditions. Further details are explained below:
FABRICATION
Stresses generated from sanding, grinding, drilling, polishing, ma-chining, sawing and/or forming (hot or cold).
EXPOSURE
Exposure duration, stresses imparted during the application life-cycle due to loads, temperature changes, heat, environments, etc.
APPLICATION OF CHEMICALS
Application from contact, rubbing, wiping, spraying, soaking, etc.
Also having an affect is the relative concentration of the chemical in question.
Selected Mechanical and Physical Properties for 3form Varia Ecoresin Values reported for Varia Ecoresin with no decorative inserts. Deco-rative inserts may increase or may decrease specific test results.
Should your application require specific test values, consult the 3form Product Technology Department.
TYPICAL VALUE
0.118" (3 MM) 0.236" (6 MM)
PROPERTY* ASTM METHOD SI U.S. SI U.S.
GENERAL
Density D 1505 1,270 kg/m3 79 lb/ft3 1,270 kg/m3 79 lb/ft3
Water Absorption
D 570 23° C (73° F), 24h immersion
0.2% 0.2% 0.1% 0.1%
MECHANICAL
Tensile Stress @ Yield
D 638 53 MPa 7,700 psi 53 MPa 7,700 psi
Tensile Stress @ Break
D 638 26 MPa 3,800 psi 26 MPa 3,800 psi
Elongation @ Yield D 638 4.8% 4.8% 5.0% 5.0%
Elongation @ Break D 638 50% 50% 40% 40%
Tensile Modulus D 638 2,200 MPa 320,000 psi
Flexural Modulus D 790 2,100 MPa 310,000 psi
2,000 MPa 290,000 psi
Flexural Strength D 790 77 MPa 11,200 psi 83 MPa 12,000 psi
Shear Strength D 732 62 MPa 9,000 psi 62 MPa 9,000 psi
Shear Modulus — 793 MPa 115,000 psi — —
Rockwell Hardness D 785 115 115 117 117
Safety Glazing ANSI 97.1 PASS PASS
Izod Impact Strength, Notched
D 256 @ 73°F D 256 @ 32°F D 256 @–22°F
88 J/m 66 J/m 39 J/m
1.7 ft·lbf/in.
1.2 ft·lbf/in.
0.7 ft·lbf/in.
62 J/m
1.2 ft·lbf/in.
Impact Strength, Unnotched
D 4812 @ 73°F D 4812 @ 32°F D 4812 @ –22°F
NB**
NBB
NBB
NB**
NBB
NBB
NB**
NB**
Impact Resistance— Puncture, Energy @ Max. Load
D 3763 @ 73°F D 3763 @ 32°F D 3763 @ 14°F D 3763 @ –4°F D 3763 @ –22°F
33 J 40 J 42 J 43 J 47 J
24 ft·lbf 30 ft·lbf 31 ft·lbf 32 ft·lbf 34 ft·lbf
71 J 93 J 96 J >100 J >100 J
53 ft·lbf 69 ft·lbf 71 ft·lbf >74 ft·lbf >74 ft·lbf
THERMAL
Cont. Max Use Temperature -Varia
– 65ºC 150ºF 65ºC 150ºF
Cont. Max Use Tem-perature - Dichroic/ Reflect
– 60ºC 140ºF 60ºC 140ºF
Heat Deflection Temp
D 648 @ 264psi 70ºC 157ºF 73ºC 164ºF
Vicat Softening Temperature
D 1525 @ 1 kg 83ºC 181ºF — —
Forming Tempera-ture
— 138-160ºC 280-320ºF — —
Thermal Conduc-tivity
ASTM D 5930 0.205 W/
m·K
0.118 Btu/
hr·ft2·ºF
0.205 W/
m·K
0.118 Btu/
hr·ft2·ºF
Coefficient of Ther-mal Expansion
ASTM D 696 7x10-5 mm/ mm/ºC
4x10-5 in/ in/ºF
7x10-5 mm/ mm/ºC
4x10-5 in/ in/ºF
*Unless noted otherwise, all tests are run @ 73°F (23°C) and 50% relative humidity, using specimens machined from extruded sheeting with a thickness as indicated.
**Nonbreak as defined in ASTM D 4812 using specimens having a thickness as indicated.
Properties reported here are typical of average lots. 3form makes no representation that the material in any particular shipment will conform exactly to the values given.
5FEBRUARY 15 2019 | MATSPEC - VARIA | REV 034
The following data is based on complete immersion of Varia Ecoresin in the chemical or reagent shown. Samples remained immersed and were stored at 73ºF (23ºC) for a period of one year. Following the test period the samples were removed from immersion and inspected.
The following table provides indicative performance of the chemical resistance characteristics of Ecoresin. The following codes are used to describe the chemical resistance characteristics:
R = RESISTANT
3form Varia Ecoresin is able to withstand the identified compound for long exposure periods up to 120ºF (7 days, full immersion)
LR = LIMITED RESISTANCE
3form Varia Ecoresin is only resistant when in contact with this compound for short periods at room temperature. It is advised that further determination of the effect of the substance be further tested in your particular application.
NR = NOT RESISTANT
3form Varia Ecoresin is not resistant to the compound. The material will swell, craze, haze, dissolve or experience some physical change when exposed to this substance.
REAGENT RESULT REAGENT RESULT
Acetic Acid, 5% R Acetic Acid, conc. NR
Acetone NR Ammonium Hydroxide, conc. NR
Antifreeze, Automotive Ethylene Glycol Type
R Benzene NR
Brake Fluid, DOT3 R Brake Fluid LR
Carbon Tetrachloride NR Chromic Acid, 40% R
Citric Acid, 10% R Cottonseed Oil R
Deionized Water R Detergent, Alconox (0.25%) R
Di (2-Ethylhexyl) Phthalate R Dibutyl Sebacate R
Diesel Fuel LR Dimethyl Formamide NR
Ethanol, 50% R Ethanol, 100% R
Ethyl Acetate NR Ethylene Dichloride NR
Gasohol, 10% Ethanol LR Gasohol, 10% Methanol LR
Gasoline, Base for Gasohol LR Gasoline, Premium Unleaded LR
Gasoline, Regular R Gasoline, Regular Unleaded LR
Grease, Automotive R Hand Cleaner, Waterless Jergens
SBS30
R
Hexane R Hydrochloric Acid, conc. NR
Hydrochloric Acid, 10% R Hydrogen Peroxide, 3% R
Hydrogen Peroxide, 28% R Isooctane R
Kerosene R Lacquer Thinner LR
Methyl Alcohol LR Mineral Oil R
Motor Oil R Nitric Acid, conc. NR
Nitric Acid, 10% R Nitric Acid, 40% LR
Oleic Acid, 83% R Olive Oil R
OxiCide, product use dilution R Penetrating Oil, Liquid Wrench #1 NR
Phenol, 5% NR Silicone Spray Lubricant NR
Soap Solution, 1% R Sodium Carbonate, 2% R
Sodium Carbonate, 20% R Sodium Chloride, 10% R
Sodium Hydroxide, 1% R Sodium Hydroxide, 10% R
Sodium Hypochlorite, 3.5% R Sulfuric Acid, conc. NR
Sulfuric Acid, 3% R Sulfuric Acid, 30% R
Tapping Oil R Toluene NR
Transformer Oil LR Transmission Fluid, Auto R
Turpentine LR
Cleaning Instructions 3form Varia Ecoresin, like all thermoplastic resin materials, should be cleaned periodically. A regular, seasonal cleaning program will dramatically help prevent noticeable weathering and dirt build-up.
3form recommends the use of the following common cleaning prod-ucts: Windex, Formula 409, Simple Green, Fantastik, Virex, 10:1 Water/ Bleach Solution.
Rinse the sheets with lukewarm water. (Be careful not to expose edges of organic or fabric interlayers to water) Remove dust and dirt from Varia Ecoresin with a soft cloth or sponge and a solution of mild soap and/or liquid detergent in water. A 50:50 solution of isopropyl alcohol and water also works well. Rinse thoroughly with lukewarm water.
Always use a soft, damp cloth to blot dry. Rubbing with a dry cloth can scratch the material and create a static charge. Never use scrapers or squeegees on Varia Ecoresin. Also avoid scouring com-pounds, gasoline, benzene, acetone, carbon tetrachloride, certain deicing fluids, lacquer thinner or other strong solvents.
Writeable: Erasable markers contain an ink that dries instantly and should be easily erased. After a period of use, a film or haze could de-velop on the surface, which is the result of the ink residue that might not be completely removed when the board is erased.
By using a spray on type of glass cleaner, the board may be given a thorough cleaning. Simply spray the surface and briskly rub with a clean microfiber cloth. Rinse with clear water. Avoid using caustic or abrasive types of cleaners.
DO:
• Keep edges dry and free of liquids
• Apply cleaning solution or water to a clean cloth and wipe resin clean
DO NOT:
• Use a squeegee.
• Use strong solvents, highly alkaline or abrasive cleaning agents.
• Clean in hot sun or at elevated temperatures.
• Rub with a dry cloth.
• Do not completely saturate panel with cleaning solution or water
• Expose organic or fabric interlayers to water or cleaning solution
PRESSURE WASHING
Pressure washing can also be an effective way to remove miscella-neous debris from surfaces of 3form Varia Ecoresin installations that are in exterior or hard-to-reach places.
Pre-soak panels with a light water spray to loosen and remove inci-dental surface debris.
It is recommended that the water pressure for cleaning Varia Ecoresin panels be 1,500 psi or less. 3form Varia Ecoresin is a tough material but can be damaged if high pressure is concentrated in a single position too long. Use a gradual sweeping motion over the ap-plication. Never concentrate water spray in a single position. Pressure nozzle should never be positioned closer than 8 inches (203 mm) from the panel surface.
Test a portion of the sheet first before spraying. If test piece shows any sign of material fatigue, abrasion or delamination – discontinue
6FEBRUARY 15 2019 | MATSPEC - VARIA | REV 034
pressure washing and proceed with manual cleaning instructions as described above.
Coated or painted parts are not suitable for pressure washing as finish may be stripped off. Pressure washing is also not suitable for Varia Ecoresin panels that have been edge sealed or seamed. If using detergent, use mild detergents only. Rinse sheet with light water spray after washing.
DO NOT:
• Concentrate spray in single position.
• Use more than 1,500 psi pressure.
• Position pressure nozzle closer than 8" (203 mm) from panel.
• Proceed with pressure washing if test piece shows detrimental effects to panel.
• Pressure wash Varia Ecoresin panels that have been painted or coated to maintain coating integrity.
• Pressure wash Varia Ecoresin panels with sealed edges to ensure edge seals remain in tact.
If debris or dirt is not removed by pressure washing attempt to clean with manual procedures described in preceding section.
WRITEABLE FINISH
Use Low Odor Dry Erase markers from a reputable brand. It is best to store markers horizontally so that the felt tips do not dry out. Avoid using markers with dried out tips.
Use a dry, soft cloth for cleaning. Press firmly when erasing using a circular motion.
Please remember to use a clean cloth/eraser when erasing. A dirty cloth/eraser will leave ink residue on the writing surface. Microfiber cloths are preferred over felt erasers because they can be machine laundered making them easier to keep clean.
For periodic cleaning, rinse the entire writing surface with soapy water and then dry with a soft cloth.
To remove any permanent marker ink, use a 50:50 solvent solution of isopropyl alcohol and water. You can also trace over any areas of permanent marker ink with a dry erase marker and erase using a dry, soft cloth.
DO NOT:
• Use sharp objects such as pens, pointers, metal magnets, rings/ jewelry, knives, scrapers on your writing surface.
• Drag magnets across your writing surface.
• Use felt erasers, scouring pads or other harsh cleaners on your writing surface.
• Use any abrasive material or fingernails to remove tape or stickers.
• Expose edges of panel to moisture or cleaning solutions.
For more information, please visit 3-form.com or call 877-649-2670.
| ��� | ����� |
| �� | � |
| ������ | � |
| �� | � |
| �� | ���� | � |
| �� | ���� |
| �� | |||
| � | ��������� | �� | � |
| ��� | � |
| �� |
| ���� | �� |
| �� | � |
| ��� | ��� |
| ���� | �� |
1�����
2�����
1�����
3�����
1�����
1�����
| ���� | ���������������� | ������ |
| ����� | ������ |
| ������ | ������ | ||
| �� | ��� | �������������� | ��� |
| ��� | ������������� |
| ������ | ��������������� | ���� | ������ |
| �"���� | ����� |
| ���� | ���� | � |
| � |
| ���� | ���������������� | ������ |
| �� | ����������� | �� |
| � | ������������ |
| ����� | ����������� |
| � | ����� | ||
| ������ | ����� | ���������)��� | ������������������ |
| ����� | ���������� | ������������������ |
| ��������� | �������� |
| ������ | ���� | |
| ��������-���������� | ������� | ���������)���� |
01234567892:
;<=>?@AB=
CBDD
EFGH@ID>
JI;KB;
CKD?<J
L<MHLEHN
JLHHO ABDD<F
LI<; DKJICBLH
DI;?I@AH JI;MID
EFGH@D?BLC
DBF<?GNH D?B;>H;=H DCBOH@P;@C<LLBLD J><FFHN JIEI;I@EFGH
?BL?<FFI >HI?>HL
EGL;<D>HN@ELB;QH
?HLLI
?LBR<JD
�,��S�'�(
B
A.1
A
A.2UIP.
M
MRI ACCS.
146D
2' -5
/2
'-2
/2
17'-2"
2'-0"
8'-6"W X 9'-0"H MRI
WALL KNOCKOUT
MRI SCAN
ROOM
146C
B.1
8' -6
STEEL COLUMN,
RE: STRUCTURAL
STUCCO TO MATCH
ADJACENT EXISTING FINISH
6" METAL STUD FRAMING
W/ BATT INSULATION
2 LAYER 5/8" GYP. BD.
W/ RF SHIELDING
WEATHER BARRIER ON
EXTERIOR SHEATHING
RF / MAGNETIC SHIELDING WALL
ASSEMBLY PER SHIELDING VENDOR
1" AIR SPACE
2 LAYER 5/8" TYPE 'X' GYP. BD. ON
1 5/8" METAL STUD FRAMING
1/4" SEALANT & BACKER ROD
FIRE-RATED
SEALANT
K N
O C
K -O
U T
P A
N E
L
K N
O C
K -O
U T
P A
N E
L
1 1/2" = 1'-0"
PLAN DETAIL - 1 HR COLUMN WRAP W/ RF SHIELDING
Detail provided in response to Pre-Bid RFI Q70.
VA/Pres/Dwg/Man2
FACILITY
SHEET
DESIGNER
SHEET
DRAWN BY
SHEETSHEETSHEET
Bob Stump VA Medical Center Northern Arizona VA Health Care System
SHEETSHEET
REVISIONS
SHEETSHEET
PROJECT
SHEET
Interior Signage Manual
SHEETSHEET
SIGN TYPE
SCALE:
NORTHERN ARIZONA VA HEALTH CARE SYSTEM
INTERIOR SIGNAGE MANUAL
SHEET
DESIGNER
SHEET
DRAWN BY
SHEETSHEETSHEET
Bob Stump VA Medical Center Northern Arizona VA Health Care System
SHEETSHEET
REVISIONS
SHEETSHEET
PROJECT
SHEET
Interior Signage Manual
SHEETSHEET
SIGN TYPE
SCALE:
DW-01
EXPLODED VIEW - FRAME W/O FACE PANELS
NOT TO SCALE
SIDE VIEW - MOUNTING
NOT TO SCALE
SHEET
DESIGNER
SHEET
DRAWN BY
SHEETSHEETSHEET
Bob Stump VA Medical Center Northern Arizona VA Health Care System
SHEETSHEET
REVISIONS
SHEETSHEET
PROJECT
SHEET
Interior Signage Manual
SHEETSHEET
SIGN TYPE
SCALE:
DW-02
GRAPHIC TEXTURES COLOR PALETTES
1040 Creative CG 1C C:0 | M:0 | Y:0 | K:4 Secondary Color
Satin Anodized Aluminum Frame
Wilsonart - Magnolia Background
Primary Color
SHEET
DESIGNER
SHEET
DRAWN BY
SHEETSHEETSHEET
Bob Stump VA Medical Center Northern Arizona VA Health Care System
SHEETSHEET
REVISIONS
SHEETSHEET
PROJECT
SHEET
Interior Signage Manual
SHEETSHEET
SIGN TYPE
SCALE:
DW-03
NOTES:
A.
B.
C.
D.
E.
ADA Tactile Numbers & Grade II Braille
2 Ply Construction w/ 1/8” P95 Frosted Acrylic w/ Subsurface VOC Free Digital Printed Background Adhered to Sintra
Magnetically Mounted 3Ply Non-Glare Acrylic Construction w/ Subsurface VOC Free Digitally Printed Background & Acetate Insert.
Beveled FrameExisting
2 Ply Non-Glare Acrylic Construction Subsurface VOC Free Digitally Printed Copy, Graphic & Background where Applicable
1”=3”
ADA ROOM
NUMBER/IDENTIFICATION
SIGN SYSTEM STANDARDS INTERIOR FAMILY OF COMPONENTS - Existing Beveled Frame
FINISHES:
FINISH F2 -
SATIN ALUMINUM
FINISH F1
LAMINATE
Wilsonart Magnolia (Magnolia - Leno Weave 5012)
COLOR C2 -
COOL GREY
Creative CG 1C (1040)
COLOR C1 -
Creative 541c
COLOR C4 -
BRIGHT WHITE
Creative White
COLOR C3-
Black CSS Black
2J-100 A
B
D
C1
R1
TYPE: D1A/W
9”
3”
Conference Room
2J-100
9”
3”
6”
9”
A
B
C
R1
TYPE: D1A/F/W
C1
D
COLOR R1 -
BRIGHT WHITE
Rowmark White
COLOR R2 -
BLACK
Rowmark Black
TYPE: SA/W
ROOM NUMBER / IDENTIFICATION
D
E
A R2
C2
SHEET
DESIGNER
SHEET
DRAWN BY
SHEETSHEETSHEET
Bob Stump VA Medical Center Northern Arizona VA Health Care System
SHEETSHEET
REVISIONS
SHEETSHEET
PROJECT
SHEET
Interior Signage Manual
SHEETSHEET
SIGN TYPE
SCALE:
DW-04
NOTES:
1/16" Non-Glare Removable Lens & Removable Background Panel w/ Surface VOC Free Digital Printed Copy, Graphic & Background
1/16" Non-Glare Removable Lens with Subsurface VOC Free Digital Printed Copy & Removable Background Panel w/ Surface VOC Free Digital Printed Background
K.
L.
F.
G.
H.
I.
Component Based System w/ Spring Clip Loading for Interchangeable Variable Depth Media
Slider Unit - Digitally Printed Background
2 Ply Non-Glare Acrylic Construction Subsurface VOC Free Digital Printed Copy, Graphics & Background
1/16" Non-Glare Removable Lens with Subsurface VOC Free Digital Printed Copy & Removable Background Panel
3 Ply Non-Glare Acrylic Construction Subsurface VOC Free Digital Printed Background & Copy
J.
A.
B.
C.
D.
E.
ADA Tactile Numbers & Grade II Braille
1/8” P95 Frosted Acrylic w/ Subsurface VOC Free Digitally Printed Background, Graphic & Surface Voc Free Digitally Printed Copy where applicable
Removable Aluminum Accent
Non-Glare Removable Lense w/ Subsurface VOC Free Digital Printed Graphic/Copy where Applicable & Removable Background Panel w/ Wilsonart Laminate adhered to ACM
Non-Glare Removable Lens, Acetate Insert & Removable Background Panel w/ Wilsonart Laminate adhered to ACM
75% Recycled Aluminum Anodized Holder;
Mechanically Fastens to the Wall (Limits Future Wall Damage)
M.
F1192
Staff Workroom
8-½”
2-¾”
5-½”
8-½”
A
B
C
E
G
F
F12043-¼”
8-½”
A
B
F
G
1”=3”
ADA ROOM
NUMBER/IDENTIFICATION
SIGN SYSTEM STANDARDS
R1
F1
C1
R1
F2
TYPE: D1A/Wc
TYPE: D1A/F/Wc
F1226
8-½”
2-¾”
5-½” 10-¾”
Vacant2-¼”
A
B
C
E
G
F
H
TYPE: D1A/F/O/Wc
ROOM NUMBER / IDENTIFICATION
R1
In Use
Conference Room
C1 F2
C1
FINISHES:
FINISH F2 -
SATIN ALUMINUM
FINISH F1
LAMINATE
Wilsonart Magnolia (Magnolia - Leno Weave 5012)
COLOR R1 -
BRIGHT WHITE
Rowmark White
COLOR C2 -
COOL GREY
Creative CG 1C (1040)
COLOR C4 -
BRIGHT WHITE
Creative White
COLOR C3-
Black CSS Black
COLOR C5 - RED
CSS Fire Red
C4 C5
COLOR C1 -
Creative 541c
CREATIVE Continuum Brand Name or Equal
SHEET
DESIGNER
SHEET
DRAWN BY
SHEETSHEETSHEET
Bob Stump VA Medical Center Northern Arizona VA Health Care System
SHEETSHEET
REVISIONS
SHEETSHEET
PROJECT
SHEET
Interior Signage Manual
SHEETSHEET
SIGN TYPE
SCALE:
DW-05
NOTES:
MEN
F1209
FINISHES:
F1
8-½"
WOMEN
,Restroom
8-½”
8-½”
F
D
G
F12072-¾” A
B
C
11-½”
F1
R1
F2
R2
TYPE: D1A/SA/Wc
1” = 3”
Room Identification
C1
FINISH F2 -
SATIN ALUMINUM
FINISH F1
LAMINATE
Wilsonart Magnolia (Magnolia - Leno Weave 5012)
COLOR R1 -
BRIGHT WHITE
Rowmark White
COLOR R2 -
BLACK
Rowmark Black
F2
F2
R2
COLOR C2 -
COOL GREY
Creative CG 1C (1040)
COLOR C3-
Black CSS Black
C1
F2
F1
F1
F2
SIGN SYSTEM STANDARDS
COLOR C1 -
Creative 541c
1/16" Non-Glare Removable Lens & Removable Background Panel w/ Surface VOC Free Digital Printed Copy, Graphic & Background
1/16" Non-Glare Removable Lens with Subsurface VOC Free Digital Printed Copy & Removable Background Panel w/ Surface VOC Free Digital Printed Background
K.
L.
F.
G.
H.
I.
Component Based System w/ Spring Clip Loading for Interchangeable Variable Depth Media
Slider Unit - Digitally Printed Background
2 Ply Non-Glare Acrylic Construction Subsurface VOC Free Digital Printed Copy, Graphics & Background
1/16" Non-Glare Removable Lens with Subsurface VOC Free Digital Printed Copy & Removable Background Panel
3 Ply Non-Glare Acrylic Construction Subsurface VOC Free Digital Printed Background & Copy
J.
A.
B.
C.
D.
E.
ADA Tactile Numbers & Grade II Braille
1/8” P95 Frosted Acrylic w/ Subsurface VOC Free Digitally Printed Background, Graphic & Surface Voc Free Digitally Printed Copy where applicable
Removable Aluminum Accent
Non-Glare Removable Lense w/ Subsurface VOC Free Digital Printed Graphic/Copy where Applicable & Removable Background Panel w/ Wilsonart Laminate adhered to ACM
Non-Glare Removable Lens, Acetate Insert & Removable Background Panel w/ Wilsonart Laminate adhered to ACM
75% Recycled Aluminum Anodized Holder;
Mechanically Fastens to the Wall (Limits Future Wall Damage)
M.
SHEET
DESIGNER
SHEET
DRAWN BY
SHEETSHEETSHEET
Bob Stump VA Medical Center Northern Arizona VA Health Care System
SHEETSHEET
REVISIONS
SHEETSHEET
PROJECT
SHEET
Interior Signage Manual
SHEETSHEET
SIGN TYPE
SCALE:
DW-06
SCALE: 1” = 4”
NOTES:
Directional / Pocket Sign
CHAPERONE & UNATTENDED
CHILDREN POLICY
Every patient (and healthcare provider) has a right to have a chaperone present during a medical examination. If you so desire, please notify the clinic staff.
IAW TAMC regulation 101, unattended children 10 years of age and younger are not authorized in the department of radiology. An adult, other than the patient must accompany these children.
8-½”
11”
TYPE: P/Wc
INSERT HOLDER
F
G
E
F2
Keep Locked at All Times
5-½”
8-½”
F
G
D
TYPE: E/Wc
PERMANENT MESSAGE SIGN
8-½”
Lab TYPE: P5/Wc
DIRECTIONAL SIGN
F
G
D
8-½”
FINISHES:
8-½”
11”
TYPE: E1/P/Wc
TERTIARY DIRECTIONAL
F
G
E
F2
2-3/4”
11”
17”
TYPE: E/P/Wc
ELEVATOR DIRECTORY
F
G
E
3” Directory
FINISH F2 -
SATIN ALUMINUM
FINISH F1
LAMINATE
Wilsonart Magnolia (Magnolia - Leno Weave 5012)
COLOR C2 -
COOL GREY
Creative CG 1C (1040)
F1
F2
F1
B C1
F1
F2
F1
F2
F1
B C1
COLOR C4 -
BRIGHT WHITE
Creative White
COLOR C3-
Black CSS Black
C4 C4
C
1/16" Non-Glare Removable Lens & Removable Background Panel w/ Surface VOC Free Digital Printed Copy, Graphic & Background
1/16" Non-Glare Removable Lens with Subsurface VOC Free Digital Printed Copy & Removable Background Panel w/ Surface VOC Free Digital Printed Background
K.
L.
F.
G.
H.
I.
Component Based System w/ Spring Clip Loading for Interchangeable Variable Depth Media
Slider Unit - Digitally Printed Background
2 Ply Non-Glare Acrylic Construction Subsurface VOC Free Digital Printed Copy, Graphics & Background
1/16" Non-Glare Removable Lens with Subsurface VOC Free Digital Printed Copy & Removable Background Panel
3 Ply Non-Glare Acrylic Construction Subsurface VOC Free Digital Printed Background & Copy
J.
A.
B.
C.
D.
E.
ADA Tactile Numbers & Grade II Braille
1/8” P95 Frosted Acrylic w/ Subsurface VOC Free Digitally Printed Background, Graphic & Surface Voc Free Digitally Printed Copy where applicable
Removable Aluminum Accent
Non-Glare Removable Lense w/ Subsurface VOC Free Digital Printed Graphic/Copy where Applicable & Removable Background Panel w/ Wilsonart Laminate adhered to ACM
Non-Glare Removable Lens, Acetate Insert & Removable Background Panel w/ Wilsonart Laminate adhered to ACM
75% Recycled Aluminum Anodized Holder;
Mechanically Fastens to the Wall (Limits Future Wall Damage)
M.
COLOR C1 -
SIGN SYSTEM STANDARDS CREATIVE Continuum Brand Name or Equal
SHEET
DESIGNER
SHEET
DRAWN BY
SHEETSHEETSHEET
Bob Stump VA Medical Center Northern Arizona VA Health Care System
SHEETSHEET
REVISIONS
SHEETSHEET
PROJECT
SHEET
Interior Signage Manual
SHEETSHEET
SIGN TYPE
SCALE:
DW-07
11”
3”
33”
17”
• Buildings 20-24
• Patriot Café (20)
• Pharmacy (21)
• Welcome Desk
BLDG
3”
TYPE: Cc-2/P-2/Cc/Wc
DOUBLE DIRECTIONAL SIGN
FLOOR 2
Buildings 20-24 •
Patriot Café (20) •
Pharmacy (21) •
Welcome Desk •
3”
11”
11”
3”
18”
17”
TYPE: Cc/P/Cc/Wc
SMALL DIRECTIONAL SIGN
• Buildings 20-24
• Patriot Café (20)
• Pharmacy (21)
• Welcome Desk
BLDG
3” FLOOR 2
1” = 5”
NOTES:
Large Directional Pocket Sign
B
E
F
G
F2
F1
FINISHES:
FINISH F2 -
SATIN ALUMINUM
FINISH F1
LAMINATE
Wilsonart Magnolia (Magnolia - Leno Weave 5012)
COLOR C2 -
COOL GREY
Creative CG 1C (1040)
COLOR C4 -
BRIGHT WHITE
Creative White
COLOR C3-
Black CSS Black
C1 C4
B C1 C4
PATTERN P1 -
P1
B
E
F
G
F2
F1
C1 C4
B C1 C4 P1
B
E F1
C1 C4
SIGN SYSTEM STANDARDS CREATIVE Continuum Brand Name or Equal
COLOR C1 -
Creative 541c
1/16" Non-Glare Removable Lens & Removable Background Panel w/ Surface VOC Free Digital Printed Copy, Graphic & Background
1/16" Non-Glare Removable Lens with Subsurface VOC Free Digital Printed Copy & Removable Background Panel w/ Surface VOC Free Digital Printed Background
K.
L.
F.
G.
H.
I.
Component Based System w/ Spring Clip Loading for Interchangeable Variable Depth Media
Slider Unit - Digitally Printed Background
2 Ply Non-Glare Acrylic Construction Subsurface VOC Free Digital Printed Copy, Graphics & Background
1/16" Non-Glare Removable Lens with Subsurface VOC Free Digital Printed Copy & Removable Background Panel
3 Ply Non-Glare Acrylic Construction Subsurface VOC Free Digital Printed Background & Copy
J.
A.
B.
C.
D.
E.
ADA Tactile Numbers & Grade II Braille
1/8” P95 Frosted Acrylic w/ Subsurface VOC Free Digitally Printed Background, Graphic & Surface Voc Free Digitally Printed Copy where applicable
Removable Aluminum Accent
Non-Glare Removable Lense w/ Subsurface VOC Free Digital Printed Graphic/Copy where Applicable & Removable Background Panel w/ Wilsonart Laminate adhered to ACM
Non-Glare Removable Lens, Acetate Insert & Removable Background Panel w/ Wilsonart Laminate adhered to ACM
75% Recycled Aluminum Anodized Holder;
Mechanically Fastens to the Wall (Limits Future Wall Damage)
SHEET
DESIGNER
SHEET
DRAWN BY
SHEETSHEETSHEET
Bob Stump VA Medical Center Northern Arizona VA Health Care System
SHEETSHEET
REVISIONS
SHEETSHEET
PROJECT
SHEET
Interior Signage Manual
SHEETSHEET
SIGN TYPE
SCALE:
DW-08
NOTES:
2 Ply Non-Glare Acrylic Construction Subsurface VOC Free Digital Printed Background
Steel Cable Hanging System
A.
B.
Cable
Bracket
Header
2-Ply Non-Glare Acrylic
Ceiling Mount
B B
B
C2 C2
C2
FINISHES:
Pharmacy
ENT/Plastics Comp & Pen
COLOR C2 -
COOL GREY
Creative CG 1C (1040)
COLOR C3-
Black CSS Black
C1
C1 C1
COLOR C1 -
SHEET
DESIGNER
SHEET
DRAWN BY
SHEETSHEETSHEET
Bob Stump VA Medical Center Northern Arizona VA Health Care System
SHEETSHEET
REVISIONS
SHEETSHEET
PROJECT
SHEET
Interior Signage Manual
SHEETSHEET
SIGN TYPE
SCALE:
DW-09
NOTES: 1” = 3”
Overhead Room Identification
C2
FINISHES:
C2
12”
Waiting Room
FINISH F2 -
SATIN ALUMINUM
COLOR C2 -
COOL GREY
Creative CG 1C (1040)
COLOR C3-
Black CSS Black
C1 C1
F2F2
3 Ply Non-Glare Acrylic Construction Subsurface VOC Free Digital Printed Background
75% Recycled Aluminum Anodized Holder;
Mechanically Fastens to the Wall (Limits Future Wall Damage)
A.
B.
B B
AA
COLOR C1 -
SHEET
DESIGNER
SHEET
DRAWN BY
SHEETSHEETSHEET
Bob Stump VA Medical Center Northern Arizona VA Health Care System
SHEETSHEET
REVISIONS
SHEETSHEET
PROJECT
SHEET
Interior Signage Manual
SHEETSHEET
SIGN TYPE
SCALE:
DW-010
SCALE: 1” = 6”
Architectural Letters - Finish & Size Varies
Compensation & Pension 4” x ¼” Cut-Out Aluminum Letters
& 2” x ¼” Cut-Out Aluminum Diamonds Satin Aluminum Finish
Font: Futura Md Bt
Compensation & PensionCompensation & Pension
6” x ¼” Cut-Out Aluminum Letters & 3” x ¼” Cut-Out Aluminum Diamonds
Satin Aluminum Finish Font: Futura Md Bt
SHEET
DESIGNER
SHEET
DRAWN BY
SHEETSHEETSHEET
Bob Stump VA Medical Center Northern Arizona VA Health Care System
SHEETSHEET
REVISIONS
SHEETSHEET
PROJECT
SHEET
Interior Signage Manual
SHEETSHEET
SIGN TYPE
SCALE:
DW-011
NOTES:
TYPE: A4/A2/Wc
MEDIUM DIRECTORY MAP SIGN
FINISHES:
22-½”
5”
28”
Directory
34 1/4”
5”
11”
17"
28”
22 1/2”
TYPE: A4/P-6/Wc
INSERT HOLDER / INFORMATION SIGN
11”
L
F
G
YOU
ARE
HERE F2
B C1
First Floor
SA
MP
LE
MA
P
Floor 1
E
B
F
G
F1
F2
C
Ambulatory Surgery
Dental Clinic
GI Procedure Lab
Hematology/Oncology
Emergency Department
Department Floor
Education Services
Clinics 3A-D
Human Resources
Inpatient Units 5A, 5B
Inpatient Units 4A, 4B
Neurology
Prosthetics
Lab/Specimen Collection
Release of Information............................G
Pathology
Ambulatory Surgery
Dental Clinic
GI Procedure Lab
Hematology/Oncology
Emergency Department
Department Floor
Education Services
Clinics 3A-D
Human Resources
Inpatient Units 5A, 5B
Inpatient Units 4A, 4B
Neurology
Prosthetics
Lab/Specimen Collection
Release of Information............................G
Pathology
Sam pl e
Li st in gs
Sam pl e
Li st in gs
Sam pl e
Li st in gs
Sam pl e
Li st in gs
FINISH F2 -
SATIN ALUMINUM
FINISH F1
LAMINATE
Wilsonart Magnolia (Magnolia - Leno Weave 5012)
COLOR C2 -
COOL GREY
Creative CG 1C (1040)
COLOR C4 -
BRIGHT WHITE
Creative White
COLOR C3-
Black CSS Black
PATTERN P1 -
SIGN SYSTEM STANDARDS
COLOR C1 -
Creative 541c
C4 P1 C1 C4 P1
1” = 6”
Information Signs
1/16" Non-Glare Removable Lens & Removable Background Panel w/ Surface VOC Free Digital Printed Copy, Graphic & Background
1/16" Non-Glare Removable Lens with Subsurface VOC Free Digital Printed Copy & Removable Background Panel w/ Surface VOC Free Digital Printed Background
K.
L.
F.
G.
H.
I.
Component Based System w/ Spring Clip Loading for Interchangeable Variable Depth Media
Slider Unit - Digitally Printed Background
2 Ply Non-Glare Acrylic Construction Subsurface VOC Free Digital Printed Copy, Graphics & Background
1/16" Non-Glare Removable Lens with Subsurface VOC Free Digital Printed Copy & Removable Background Panel
3 Ply Non-Glare Acrylic Construction Subsurface VOC Free Digital Printed Background & Copy
J.
A.
B.
C.
D.
E.
ADA Tactile Numbers & Grade II Braille
1/8” P95 Frosted Acrylic w/ Subsurface VOC Free Digitally Printed Background, Graphic & Surface Voc Free Digitally Printed Copy where applicable
Removable Aluminum Accent
Non-Glare Removable Lense w/ Subsurface VOC Free Digital Printed Graphic/Copy where Applicable & Removable Background Panel w/ Wilsonart Laminate adhered to ACM
Non-Glare Removable Lens, Acetate Insert & Removable Background Panel w/ Wilsonart Laminate adhered to ACM
75% Recycled Aluminum Anodized Holder;
Mechanically Fastens to the Wall (Limits Future Wall Damage)
SHEET
DESIGNER
SHEET
DRAWN BY
SHEETSHEETSHEET
Bob Stump VA Medical Center Northern Arizona VA Health Care System
SHEETSHEET
REVISIONS
SHEETSHEET
PROJECT
SHEET
Interior Signage Manual
SHEETSHEET
SIGN TYPE
SCALE:
DW-012
1”=10”
¾” Aluminum Round Stand-Off
½” Clear Acrylic Panel with Subsurface VOC Free Digitally Printed Graphics
1/16” Non-Glare Removable Lens w/ Subsurface VOC Free Digital Printed Copy/Graphic & Removable Background Panel w/ Laminate adhered to ACM (where applicable)
75% Recycled Aluminum Anodized Holder;
Mechanically Fastens to the Wall (Limits Future Wall Damage)
A.
B.
C.
D.
Component Based System w/ Sprint Clip Loading for Interchangeable Variable Depth Media
5” x ¼” Cut-Out Satin Aluminum Architectural Letters.
Typeface: Futura Md BT
1/8” Brushed Aluminum ACM w/ Surface VOC FREE Digitally Printed Graphics
3/8” Frosted Acrylic w/ Subsurface VOC Free Digitally Printed Background
E.
F.
G.
H.
24” 20”
6”
18”
9”
8”
18”
19”
4”
5”
30”
37”
24” 47”
G
C
D
E
Main Entry Policy Feature Wall
VA F
or m
AKA
Pol ic ie s & D ire ct iv es
M an da to ry P ol ic y Sig n
Pat ie nt
R ig ht
R es po ns ib ilit ie s
3-¼”x 20” x ¼” Cut-Out Satin Aluminum LogotypeI.
B
A
I
H
NOTE: Please confirm Image Panel final dimension.
F
FINISH F2 -
SATIN ALUMINUM
COLOR C2 -
COOL GREY
Creative CG 1C (1040)
COLOR C3-
Black CSS Black
NOTES: FINISHES:
F2
F2
F2
COLOR C1 -
SHEET
DESIGNER
SHEET
DRAWN BY
SHEETSHEETSHEET
Bob Stump VA Medical Center Northern Arizona VA Health Care System
SHEETSHEET
REVISIONS
SHEETSHEET
PROJECT
SHEET
Interior Signage Manual
SHEETSHEET
SIGN TYPE
SCALE:
DW-013
Caution Radiation
Bio-Hazard Eye Wash
Authorized Personnel Only
TYPE: Q/Wc
REGULATORY SIGN
TYPE: S/Wc
LIFE SAFETY SIGN
8-½”
8-½”
TYPE: R/Wc
REGULATORY SIGN
TYPE: R/Wc
LIFE SAFETY SIGN
F
L
G
NOTES: FINISHES:
F
L
G
F
L
G
F
L
G
F2F2
F2 F2
8-½”
8-½”
8-½”
8-½”
8-½”
8-½”
1/16" Non-Glare Removable Lens & Removable Background Panel w/ Surface VOC Free Digital Printed Copy, Graphic & Background
1/16" Non-Glare Removable Lens with Subsurface VOC Free Digital Printed Copy & Removable Background Panel w/ Surface VOC Free Digital Printed Background
K.
L.
F.
G.
H.
I.
J.
A.
B.
C.
D.
E.
ADA Tactile Numbers & Grade II Braille
Removable Background Panel with Laminate adhered to ACM, & VOC FREE Digitally Printed where Applicable
Removable Aluminum Accent
Non-Glare Removable Lense w/ Subsurface VOC Free Digital Printed Graphic/Copy, & Removable Background Panel w/ Wilsonart Laminate adhered to ACM
Non-Glare Removable Lens, Acetate Insert & Removable Background Panel w/ Wilsonart Laminate adhered to ACM
75% Recycled Aluminum Anodized Holder;
Mechanically Fastens to the Wall (Limits Future Wall Damage)
M.
Component Based System w/ Spring Clip Loading for Interchangeable Variable Depth Media
Slider Unit - Digitally Printed Background
2 Ply Non-Glare Acrylic Construction Subsurface VOC Free Digital Printed Copy, Graphics & Background
1/16" Non-Glare Removable Lens with Subsurface VOC Free Digital Printed Copy & Removable Background Panel
3 Ply Non-Glare Acrylic Construction Subsurface VOC Free Digital Printed Background & Copy
FINISH F2 -
SATIN ALUMINUM
COLOR C3-
Black CSS Black
COLOR C4 -
BRIGHT WHITE
Creative White
1”=4”
Regulatory Signs
SHEET
DESIGNER
SHEET
DRAWN BY
SHEETSHEETSHEET
Bob Stump VA Medical Center Northern Arizona VA Health Care System
SHEETSHEET
REVISIONS
SHEETSHEET
PROJECT
SHEET
Interior Signage Manual
SHEETSHEET
SIGN TYPE
SCALE:
DW-014
FIRE
DOOR
KEEP CLOSED
at all times
8-½”
COLOR C5 - RED
CSS Fire Red
TYPE: V4/Wc
REGULATORY SIGN
TYPE: V3/Wc
ELEVATOR WARNING SIGN
F
L
G
NOTES: FINISHES:
F
L
G
9”
9”
TYPE: G D/F
PROJECTING/LIFE SAFETY SIGN
K
F
9”
9”
TYPE: G D/F
PROJECTING/LIFE SAFETY SIGN
K
F
COLOR C4 -
BRIGHT WHITE
Creative White
F2 F2 F2
F2
1/16" Non-Glare Removable Lens & Removable Background Panel w/ Surface VOC Free Digital Printed Copy, Graphic & Background
1/16" Non-Glare Removable Lens with Subsurface VOC Free Digital Printed Copy & Removable Background Panel w/ Surface VOC Free Digital Printed Background
K.
L.
F.
G.
H.
I.
J.
A.
B.
C.
D.
E.
ADA Tactile Numbers & Grade II Braille
Removable Background Panel with Laminate adhered to ACM, & VOC FREE Digitally Printed where Applicable
Removable Aluminum Accent
Non-Glare Removable Lense w/ Subsurface VOC Free Digital Printed Graphic/Copy, & Removable Background Panel w/ Wilsonart Laminate adhered to ACM
Non-Glare Removable Lens, Acetate Insert & Removable Background Panel w/ Wilsonart Laminate adhered to ACM
75% Recycled Aluminum Anodized Holder;
Mechanically Fastens to the Wall (Limits Future Wall Damage)
M.
8-½”
8-½”
8-½”
Component Based System w/ Spring Clip Loading for Interchangeable Variable Depth Media
Slider Unit - Digitally Printed Background
2 Ply Non-Glare Acrylic Construction Subsurface VOC Free Digital Printed Copy, Graphics & Background
1/16" Non-Glare Removable Lens with Subsurface VOC Free Digital Printed Copy & Removable Background Panel
3 Ply Non-Glare Acrylic Construction Subsurface VOC Free Digital Printed Background & Copy
FINISH F2 -
SATIN ALUMINUM
COLOR C3 -
Black CSS Black
1”=4”
Regulatory Signs
SHEET
DESIGNER
SHEET
DRAWN BY
SHEETSHEETSHEET
Bob Stump VA Medical Center Northern Arizona VA Health Care System
SHEETSHEET
REVISIONS
SHEETSHEET
PROJECT
SHEET
Interior Signage Manual
SHEETSHEET
SIGN TYPE
SCALE:
DW-015
Martinsburg, WV Tranquility House - Bldg 513
First Floor
LEGEND
Restrooms
Exits Elevator
Stairs
17”
Fire Extinguisher
9”
9”
TYPE: G D/F
PROJECTING/LIFE SAFETY SIGN
K
F
NOTES: FINISHES:
TYPE: V/Wc
EVACUATION PLAN
What To Do In Case Of Fire:
R A C E
RESCUE
ALARM
CONFINE
EXTINGUISH
Immediate life saving and CLOSE THAT DOOR!
Pull the alarm and call XXXX giving exact location and information.
Close doors and windows to prevent fire/smoke spread.
Know…