Addendum 01_Plans_20250820 Marion NC.pdf

PDF 35 MB Posted

Attached to
Y1PZ--817CM3025 New Land Expansion at Marion National Cemetery
Solicitation number
36C78625B0035_1
Issued by

About this file

This file contains engineering and architectural design documents for the Marion National Cemetery New Land Expansion project (Project Number 817CM3025), prepared by Anderson Engineering of Minnesota, LLC. The comprehensive set of technical drawings covers multiple aspects of the cemetery expansion, including site plans, grading, electrical infrastructure, technology systems, and detailed burial section layouts for new pre-placed crypts and in-ground cremain sections.

The project involves expanding the existing national cemetery with multiple new sections, including Section 15 (1,044 pre-placed crypts), Section 16 (973 pre-placed crypts), Section 17 (1,008 pre-placed crypts), and additional in-ground cremain sections. The design includes new infrastructure such as an administration building, maintenance building, committal shelter, memorial wall, visitor parking, cortege lanes, flag assembly areas, and associated roadways and utilities. The project is being executed for the U.S. Department of Veterans Affairs National Cemetery Administration, with technical design work completed by multiple consultants including IMEG (technology), EC Design Group (irrigation), Terracon (geotechnical), and Total Cost Management (cost estimating).

View the file

Other files

File Type Posted
075323 EPDM Roofing Specification.pdf PDF
36C78625B0035 0003.docx DOCX document
Responses to Prebid RFIs 2 for 36C78625B0035 for 817CM3025 New Land Expansion at Marion NC.pdf PDF
034821PrecastConcBurialCrypts - Revised.pdf PDF
263213EngGen - Revised.pdf PDF
283100 - Fire Detection and Alarm - Revised.pdf PDF
000110TOC - Revised.pdf PDF
Addendum 01_Cover Information_20250820 Marion NC.pdf PDF
Revised Davis-Bacon Wage Determination - Building - IN20250002 08-08-2025.pdf PDF
Responses to Prebid RFIs 36C78625B0035 for 817CM3025 New Land Expansion at Marion NC.pdf PDF
36C78625B0035 0002.docx DOCX document
072726Fluid-Applied Membrane - Revised.pdf PDF
Revised Davis-Bacon Wage Determination - Heavy - IN20250006 08-08-2025.pdf PDF
329000Planting - Revised.pdf PDF
312011EarthMovingSF - Revised.pdf PDF
36C78625B0035 0001.docx DOCX document
Prebid Site Visit Attendance Sheet 817CM3025 New Land Expansion at Marion NC_ 07-17-2025.pdf PDF
Drawings_Vol-6_817CM3025_Marion NC.pdf PDF
Drawings_Vol-8_817CM3025_Marion NC.pdf PDF
Bid Specification_Vol-1 817CM3025_Marion NC.pdf PDF
Davis-Bacon Wage Determination - Heavy - IN20250006 05-23-2025.pdf PDF
Solicitation 36C78625B0035 for 817CM3025 New Land Expansion at Marion NC.docx DOCX document
IFB Cost Estimate Worksheet.xlsx XLSX spreadsheet
Drawings_Vol-7_817CM3025_Marion NC.pdf PDF
Davis-Bacon Wage Determination - Building - IN20250006 05-23-2025.pdf PDF
VAAR 852.219-75 VA Notice of Limitations On Subcontracting Certificate.docx DOCX document
Drawings_Vol-3_817CM3025_Marion NC.pdf PDF
Drawings_Vol-10_817CM3025_Marion NC.pdf PDF
Drawings_Vol-4_817CM3025_Marion NC.pdf PDF
Drawings_Vol-2_817CM3025_Marion NC.pdf PDF
Drawings_Vol-9_817CM3025_Marion NC.pdf PDF
Drawings_Vol-5_817CM3025_Marion NC.pdf PDF
Bid Specification_Vol-2 817CM3025_Marion NC.pdf PDF
Show all 33

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

B

1 Y

A

BX

Y

X

C

CX

X

C

EM

ET

ER

Y R

O

AD

A

IN

DIA

NA A

VENUE

PPC

SECTION 17

(1008)

IGC

SECTION CS-8

(1457)

PPC

SECTION 16

(973)

PPC

SECTION 15

(1044)

IGC

SECTION CS-7

(445)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h:

y

:\1

\1 m ar io n nc ne w la nd e xp an si on c iv il\

_0 ca d fil es s he et s\

1_ c_ si te p la n.

dw g ed it:

bn or he im s av ed

:1 0/

/2

:3

AM

p lo t:1 0/

/2

4:

P M

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

TECHNOLOGY:

IMEG

11044 RESEARCH BLVD.

A-230

AUSTIN, TX 78759

309.786.5092

JAYSON STICKROD, PE

Project Director

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 17101

MARION NATIONAL CEMETERY

NEW LAND EXPANSION

817CM3025

OCTOBER 30, 2024

1700 E 38TH ST, MARION, IN 46953

Date:

IRRIGATION:

EC DESIGN GROUP, LTD

400 5TH STREET

WEST DES MOINES, IA 50265

515.225.6365

ERIK CHRISTIANSEN, ASIC

GEOTECHNICAL:

TERRACON

7770 WEST NEW YORK ST.

INDIANAPOLIS, IN 46214

317.746.7925

RICHARD D. OLSON, PE

COST ESTIMATING:

TOTAL COST MANAGEMENT, LLC

13602 DULUTH DRIVE

APPLE VALLEY, MN 55124

515.244.1166

BRYAN BERTRAND OF 266

KEY MAP

BID DOCUMENTS

BID DOCUMENTSI HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED

BY ME OR UNDER MY DIRECT SUPERVISION

AND THAT I AM A DULY LICENSED

PROFESSIONAL ENGINEER UNDER THE LAWS

OF THE STATE OF MINNESOTA.

DATE: LICENSE #

SIGNATURE

PRINT NAME

EDWIN J. Y. BRODMARKLE, PE

5540910/30/2024

SITE PLAN

CS101

N

0 60' 120'

SCALE:1

SITE PLAN

1" = 60' (30" x 42" PAPER SIZE)

BURIAL LEGEND

IGC IN-GROUND CREMAINS

PPC PRE-PLACED CRYPTS

TRAD DIRECT BURIAL TRADITIONAL

COL COLUMBARIUM COURT

14SLEB

EXISTING MEMORIAL

SECTION A

EXISTING

COMMITTAL SHELTER

EXISTING

CARETAKER

HOUSE/

STORAGE

LS101

CS104

CS103

CS103

CS102

LEGEND

HEADSTONE FACE DIRECTION

CEMETERY PROPERTY LINE

PROPOSED CONCRETE C&G

BITUMINOUS PAVEMENT SEE

DETAIL 1/CS502

LIGHT DUTY CONCRETE

PAVEMENT SEE DETAIL 4/CS502

HEAVY DUTY CONCRETE

PAVEMENT SEE DETAIL 5/CS502

DETECTABLE WARNING STRIP

SEE DETAIL 6/CS502

SEAL COAT SEE CP101 FOR

EXTENTS

GRAVEL SURFACING

FLOWER WATERING STATION

SEE DETAIL 2/LK503

UP-LIGHTING FIXTURE

EXISTING VEHICLE

& EQUIPMENT

STORAGE BLDG.

EXISTING

COLUMBARIUM,

TYP

CORTEGE

LANES

HONOR GUARD

STANDING ROOM

EXISTING U.S. FLAG

EXISTING

UPPER BARN

EXISTING P.O.W.

EXISTING CEMETERY ENTRY

MONUMENT SIGN

EXISTING UPPER BARN

EXISTING

EQUIPMENT

STORAGE &

WASHBAY

EXISTING

MATERIALS

BINS

NEW COLUMBARIUM

COURT

NEW C.S.S.

(7) STAFF PARKING

(11) VISITOR

PARKING

PUBLIC

INFORMATION

CENTER/

ADMINISTRATION

BUILDING

ORNAMENTAL

SLIDING GATE

ENTRANCE

FEATURE

MAINTENANCE

BUILDING

(5) HONOR

GUARD PARKING

FLAG ASSEMBLY

AREA

EXISTING GRAVESITE

LOCATOR

VHA ROAD

PROJECT BY

OTHERS

CS102

NEW MEMORIAL

WALL

CS201

OF 2661414 OF 26614

PHASE 1

PHASE 2

PHASING DESCRIPTION

PHASE 1 WORK WITHIN THE EXPANSION AREA TO

INCLUDE THE ADMINISTRATION BUILDING, CORTEGE

LANE, VISITOR PARKING, FLAG ASSEMBLY AREA,

PRE-PLACED SECTION 15, IN-GROUND CREMAINS

SECTION CS-7, ENTRNACE FEATURE AND ASSOCIATED

ROADWAYS, PEDESTRIAN PAVEMENTS AND UTILITES.

PHASE 1 WORK WITHIN THE EXISTING CEMETERY TO

INCLUDE INSTALLATION OF IRRIGATION WITHIN EXISING

BURIAL SECTIONS 8, 9, 10, 11, 12, CS-3 AND CS-2 AND

INSTALLATION OF NEW COLUMBARIUM COURT.

PHASE 2 WORK INCLUDES ALL REMAINING WORK WITHIN

THE EXPANSION AREA AND EXISTING CEMETERY.

PHASING NOTES

1) ALL WORK IN PHASE 1 TO BE COMPLETED PRIOR TO

THE START OF PHASE 2 EXCEPT FOR:

- IRRIGATION WITHIN THE EXPANSION AREA.

- TURFGRASS AND PLANTINGS WITHIN THE EXPANSION

AREA.

- ADMINISTRATION BUILDING SANITARY SEWER

CONNECTION TO MAIN IN PHASE 2 AREA.

- PHASE 1 AREA STORM SEWER CONNECTION TO MAIN IN

PHASE 2 AREA

2) CONTRACTOR SHALL SUBMIT A PLAN FOR TEMPORARY

STORMWATER COLLECTION FOR THE STORMWATER

RUNOFF WITHIN PHASE 1 AREA PRIOR TO THE

CONNECTION TO THE STORMWATER MAIN IN PHASE 2

AREA. ALL STORMWATER COLLECTION SHALL FOLLOW

SWPPP, LOCAL, STATE AND FEDERAL REQUIREMENTS.

ADDENDUM #01

8/20/2025

CONSTRUCTION PHASING

CONSTRUCTION PHASING

ADDENDUM 01 08/20/2025

C

EM

ET

ER

Y R

O

AD

A

PPC

SECTION 17

(1008)

PPC

SECTION 16

(973)

IGC

SECTION CS-8

(1457)

IGC

SECTION CS-7

(445)

PPC

SECTION 15

(1044)

IN

DIA

NA A

VENUE

A

B

1 Y

A

BX

Y

X

C

CX

X

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h:

y

:\1

\1 m ar io n nc ne w la nd e xp an si on c iv il\

_0 ca d fil es s he et s\

1_ c_ se al co at

.d w eb ro dm ar kl e sa ve d:

8/

/2

:0 lo t:8

/1 5/

0:

A

M

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

TECHNOLOGY:

IMEG

11044 RESEARCH BLVD.

A-230

AUSTIN, TX 78759

309.786.5092

JAYSON STICKROD, PE

Project Director

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 17101

MARION NATIONAL CEMETERY

NEW LAND EXPANSION

817CM3025

OCTOBER 30, 2024

1700 E 38TH ST, MARION, IN 46953

Date:

IRRIGATION:

EC DESIGN GROUP, LTD

400 5TH STREET

WEST DES MOINES, IA 50265

515.225.6365

ERIK CHRISTIANSEN, ASIC

GEOTECHNICAL:

TERRACON

7770 WEST NEW YORK ST.

INDIANAPOLIS, IN 46214

317.746.7925

RICHARD D. OLSON, PE

COST ESTIMATING:

TOTAL COST MANAGEMENT, LLC

13602 DULUTH DRIVE

APPLE VALLEY, MN 55124

515.244.1166

BRYAN BERTRAND OF 266

KEY MAP

BID DOCUMENTS

BID DOCUMENTSI HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED

BY ME OR UNDER MY DIRECT SUPERVISION

AND THAT I AM A DULY LICENSED

PROFESSIONAL ENGINEER UNDER THE LAWS

OF THE STATE OF MINNESOTA.

DATE: LICENSE #

SIGNATURE

PRINT NAME

EDWIN J. Y. BRODMARKLE, PE

5540910/30/2024 Addendum 01 08/20/20251

PAVING PLAN

CP101

N 0 100' 200'

SCALE:1

PAVING PLAN

1" = 100' (30" x 42" PAPER SIZE)

22JFJL

LEGEND

CEMETERY PROPERTY LINE

PROPOSED CONCRETE C&G

BITUMINOUS PAVEMENT SEE

DETAIL 1/CS502

LIGHT DUTY CONCRETE

PAVEMENT SEE DETAIL 4/CS502

HEAVY DUTY CONCRETE SEE

DETAIL 5/CS502

SEAL COAT

BL

AC

K

RO

AD

CHAPMAN AVENUE

INDIANA AVENUE

KUDER PLACE

IR

W

IN

D

R

IV

E

H

YD

E R

O

AD

M

AR

IO

N

R D

NOTES:

SEAL COAT WORK TO COMMENCE

DURING OPEN CEMETERY HOURS

(M-F, 8:00AM TO 4:30PM).

CONTRACTOR TO NOTIFY COR AND

CEMETERY 72 HOURS PRIOR TO

STARTING WORK.

SEAL COAT WORK TO COMMENCE

DURING CLOSED CEMETERY

HOURS. CONTRACTOR TO NOTIFY

COR AND CEMETERY 2 WEEKS

PRIOR TO STARTING WORK.

PERFORM ELECTRICAL

INSTALLATION & PAVEMENT

REMOVAL & REINSTALLATION ON

KUDER PLACE & IRWIN DRIVE

PRIOR TO SEAL COAT WORK.

36 37 38 39

43424140 44

5A

KU

D

ER

PLAC

E

CEMETERY ROAD A

SECTION

PPC

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h:

y

:\1

\1 m ar io n nc ne w la nd e xp an si on c iv il\

_0 ca d fil es s he et s\

1_ c_ la yo ut c oo rd in at io n.

dw eb ro dm ar kl d:

8/

/2

:3 lo t:8 /1

5/

0:

A M

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

TECHNOLOGY:

IMEG

11044 RESEARCH BLVD.

A-230

AUSTIN, TX 78759

309.786.5092

JAYSON STICKROD, PE

Project Director

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 17101

MARION NATIONAL CEMETERY

NEW LAND EXPANSION

817CM3025

OCTOBER 30, 2024

1700 E 38TH ST, MARION, IN 46953

Date:

IRRIGATION:

EC DESIGN GROUP, LTD

400 5TH STREET

WEST DES MOINES, IA 50265

515.225.6365

ERIK CHRISTIANSEN, ASIC

GEOTECHNICAL:

TERRACON

7770 WEST NEW YORK ST.

INDIANAPOLIS, IN 46214

317.746.7925

RICHARD D. OLSON, PE

COST ESTIMATING:

TOTAL COST MANAGEMENT, LLC

13602 DULUTH DRIVE

APPLE VALLEY, MN 55124

515.244.1166

BRYAN BERTRAND OF 266

KEY MAP

BID DOCUMENTS

BID DOCUMENTSI HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED

BY ME OR UNDER MY DIRECT SUPERVISION

AND THAT I AM A DULY LICENSED

PROFESSIONAL ENGINEER UNDER THE LAWS

OF THE STATE OF MINNESOTA.

DATE: LICENSE #

SIGNATURE

PRINT NAME

EDWIN J. Y. BRODMARKLE, PE

5540910/30/2024 Addendum 01 08/20/20251

1 PPC SECTION 15 GRAVESITE NUMBERING PLAN

SCALE: 1" = 10'

N

PROPERTY LIMITS

NEW PRE-PLACED CRYPT (3'x8')

NEW PERIMETER PRE-PLACED

CRYPT (3'X8')

NEW IN-GROUND CREMAIN (4'x4')

HEADSTONE DIRECTION

FLOWER WATERING STATION

SEE DETAIL 2/LK503

LEGEND

BURIAL TYPE QUANTITY

PRE-PLACED CRYPTS 1044

GRAVESITE SUMMARY

SECTION 15 NUMBERING PLAN

CJ401

0 10' 20'

EB SB 23

51.0' TYP. 54.5' TYP.

.0

' T

YP

.0 ' T

YP

.0

' T

YP

.0 ' T

YP

27.0'

KU

D

ER

PLAC

E

33.0'

60.0'

60.0'

CEMETERY ROAD A

.0

SECTION

PPC

GRAVESITE GRID POINTS

PT ID

ELEV

838.609

839.561

840.182

841.548

838.174

838.899

839.624

840.348

837.154

837.879

838.604

839.328

840.053

836.067

836.792

837.516

838.241

838.965

839.328

NORTHING

1921312.9151

1921318.9151

1921345.9151

1921345.9151

1921285.9151

1921285.9151

1921285.9151

1921285.9151

1921234.9151

1921234.9151

1921234.9151

1921234.9151

1921234.9151

1921180.4151

1921180.4151

1921180.4151

1921180.4151

1921180.4151

1921180.4151

EASTING

337402.7683

337450.7683

337498.7683

337546.7683

337402.7683

337450.7683

337498.7683

337546.7683

337402.7683

337450.7683

337498.7683

337546.7683

337594.7683

337402.7683

337450.7683

337498.7683

337546.7683

337594.7683

337618.7782

SECTION MARKERS

PT ID

ELEV

0.000

0.000

0.000

0.000

NORTHING

1921364.2775

1921323.1100

1921296.0265

1921185.6666

EASTING

337536.6747

337423.7678

337395.0198

337395.0168

839.131

839.025

838.209

836.001

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h:

y

:\1

\1 m ar io n nc ne w la nd e xp an si on c iv il\

_0 ca d fil es s he et s\

1_ c_ la yo ut c oo rd in at io n.

dw eb ro dm ar kl d:

8/

/2

:3 lo t:8 /1

5/

0:

A M

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

TECHNOLOGY:

IMEG

11044 RESEARCH BLVD.

A-230

AUSTIN, TX 78759

309.786.5092

JAYSON STICKROD, PE

Project Director

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 17101

MARION NATIONAL CEMETERY

NEW LAND EXPANSION

817CM3025

OCTOBER 30, 2024

1700 E 38TH ST, MARION, IN 46953

Date:

IRRIGATION:

EC DESIGN GROUP, LTD

400 5TH STREET

WEST DES MOINES, IA 50265

515.225.6365

ERIK CHRISTIANSEN, ASIC

GEOTECHNICAL:

TERRACON

7770 WEST NEW YORK ST.

INDIANAPOLIS, IN 46214

317.746.7925

RICHARD D. OLSON, PE

COST ESTIMATING:

TOTAL COST MANAGEMENT, LLC

13602 DULUTH DRIVE

APPLE VALLEY, MN 55124

515.244.1166

BRYAN BERTRAND OF 266

KEY MAP

BID DOCUMENTS

BID DOCUMENTSI HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED

BY ME OR UNDER MY DIRECT SUPERVISION

AND THAT I AM A DULY LICENSED

PROFESSIONAL ENGINEER UNDER THE LAWS

OF THE STATE OF MINNESOTA.

DATE: LICENSE #

SIGNATURE

PRINT NAME

EDWIN J. Y. BRODMARKLE, PE

5540910/30/2024 Addendum 01 08/20/20251

1 PPC SECTION 15 GRAVESITE LAYOUT PLAN

SCALE: 1" = 10'

GRAVESITE LAYOUT NOTES - GENERAL

1. SITE LAYOUT DIMENSIONS SHOWN ARE COMPUTER (AUTOCAD) GENERATED FROM ORIGINAL

ELECTRONIC SURVEY DRAWINGS. CONTRACTOR SHALL FIELD VERIFY LAYOUT DIMENSIONS PRIOR AND DURING CONSTRUCTION. NOTIFY COR IF FIELD LAYOUT DIMENSION VARY FROM PLAN BY MORE

THAN 0.5 FEET.

2. CONTRACTOR SHALL CONTACT THE COR REGARDING ANY DISCREPANCIES BETWEEN FIELD

CONDITIONS AND PLANS PRIOR TO PROCEEDING WITH WORK. THE WRITTEN DIMENSION SHALL

SUPERSEDE THE DRAWN DIMENSION. ALL FIELD ADJUSTMENTS MUST BE APPROVED BY THE COR

PRIOR TO INSTALLATION.

3. ALL DIMENSIONS ARE TO BACK OF CURB, BACK OF WALK, OR CENTER LINE OR EDGE OF PAVING, UNLESS OTHERWISE NOTED. ALL DIMENSIONS ARE AT 90 DEGREES, UNLESS OTHERWISE NOTED.

4. IF DISCREPANCIES OCCUR IN FIELD BETWEEN THIS SET OF DRAWINGS AND FIELD CONDITIONS, THE

CONTRACTOR SHALL CONTACT THE COR TO REVIEW PRIOR TO CONSTRUCTION.

5. ALL ELEMENTS TO BE INSTALLED PER PLAN DETAILS AND MANUFACTURER'S RECOMMENDATION.

6. CONTRACTOR RESPONSIBLE FOR OBTAINING ALL NECESSARY CONSTRUCTION PERMITS TO CARRY OUT ENTIRE PROJECT. PERMITS SHALL BE IN PLACE PRIOR TO ANY CONSTRUCTION ACTIVITIES.

NOTIFY APPROPRIATE UTILITY COMPANY OF ANY AND ALL PROPOSED WORK.

7. TYPICAL SPACE FOR EACH PRE-PLACED CRYPT IS 3'-0" x 8'-0". PRECAST CRYPT IS INTENDED TO BE

CENTERED WITHIN EACH GRAVE SPACE.

8. TYPICAL SPACE FOR EACH IN-GROUND CREMAIN IS INTENDED TO BE 4'-0" x 4'-0".

SECTION 15 LAYOUT PLAN

CJ402

N

PROPERTY LIMITS

NEW PRE-PLACED CRYPT (3'x8')

NEW PERIMETER PRE-PLACED

CRYPT (3'X8')

NEW IN-GROUND CREMAIN (4'x4')

HEADSTONE DIRECTION

GRID MONUMENT SEE DETAIL

4/CJ501

SECTION MARKER SEE DETAIL

1/LK502

GRID LINE

FLOWER WATERING STATION

SEE DETAIL 2/LK503

LEGEND

0 10' 20'

EB SB 24

KU

D

ER

PLAC

E

C O

C O

C O

C O

CBMH-414

RIM 838.69

INV 833.16

CO-0

RIM 838.33

INV 830.62 CBMH-412

RIM 837.83

NV 831.17

CBMH-410

RIM 835.80

INV 829.65

CO-1

RIM 840.96

INV 833.21

CO-2

RIM 840.32

INV 832.57

CO-3

RIM 839.68

INV 831.93

CEMETERY ROAD A

FW

CB-420

RIM 837.75

INV 835.00

SECTION

PPC

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h:

y

:\1

\1 m ar io n nc ne w la nd e xp an si on c iv il\

_0 ca d fil es s he et s\

1_ c_ la yo ut c oo rd in at io n.

dw eb ro dm ar kl d:

8/

/2

:3 lo t:8 /1

5/

0:

A M

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

TECHNOLOGY:

IMEG

11044 RESEARCH BLVD.

A-230

AUSTIN, TX 78759

309.786.5092

JAYSON STICKROD, PE

Project Director

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 17101

MARION NATIONAL CEMETERY

NEW LAND EXPANSION

817CM3025

OCTOBER 30, 2024

1700 E 38TH ST, MARION, IN 46953

Date:

IRRIGATION:

EC DESIGN GROUP, LTD

400 5TH STREET

WEST DES MOINES, IA 50265

515.225.6365

ERIK CHRISTIANSEN, ASIC

GEOTECHNICAL:

TERRACON

7770 WEST NEW YORK ST.

INDIANAPOLIS, IN 46214

317.746.7925

RICHARD D. OLSON, PE

COST ESTIMATING:

TOTAL COST MANAGEMENT, LLC

13602 DULUTH DRIVE

APPLE VALLEY, MN 55124

515.244.1166

BRYAN BERTRAND OF 266

KEY MAP

BID DOCUMENTS

BID DOCUMENTSI HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED

BY ME OR UNDER MY DIRECT SUPERVISION

AND THAT I AM A DULY LICENSED

PROFESSIONAL ENGINEER UNDER THE LAWS

OF THE STATE OF MINNESOTA.

DATE: LICENSE #

SIGNATURE

PRINT NAME

EDWIN J. Y. BRODMARKLE, PE

5540910/30/2024 Addendum 01 08/20/20251

1 PPC SECTION 15 GRAVESITE COORDINATION PLAN

SCALE: 1" = 10'

PROPERTY LIMITS

NEW PRE-PLACED CRYPT (3'x8')

NEW PERIMETER PRE-PLACED CRYPT

(3'X8') NEW IN-GROUND CREMAIN (4'x4')

HEADSTONE DIRECTION

GRID MONUMENT SEE DETAIL 4/CJ501

SECTION MARKER SEE DETAIL 1/LK502

STRUCTURE RIM & INVERT ELEVATION

IRRIGATION VALVE

IRRIGATION HEAD

NEW STORM STRUCTURES

IRRIGATION PIPE MAIN

IRRIGATION PIPE LATERAL

IRRIGATION COMM LINE

IRRIGATION RE-ENTERABLE

CONNECTOR

IRRIGATION SURGE PROTECTOR

FLOWER WATERING STATION SEE

DETAIL 2/LK503

PROPOSED DRAINTILE SEE DETAIL

2&3/CJ501

PROPOSED DRAINTILE CLEANOUT SEE

DETAIL 1/CJ501

N

0 10' 20'

LEGEND

SMH-205

RIM 836.79

INV 821.72

INV 821.68

SECTION 15 COORDINATION PLAN

CJ403

EB SB 25

KEY NOTES

1 1

ROUTE IRRIGATION LINE AROUND GRID MONUMENT

AND SECTION MARKER FOUNDATIONS, IRRIGATION

LINE SHALL NOT IMPEDE ON BURIAL SECTIONS.

CONTRACTOR TO STAKE ALL GRID MONUMENT,

SECTION MARKER, AND SITE ELEMENT LOCATIONS

PRIOR TO INSTALLATION OF IRRIGATION TO AVOID

CONFLICTS.

CO

849817

971963950932909880848

970962949931908879847

969961948930907878846

968960947929906877845

967959946928905876844

966958945927904875843

965957944926903874842

964956943925902873841

955942924901872840

954941923900871839

953940922899870838

952939921898869837

951938920897868836

937919896867835

936918895866834

935917894865833

934916893864832

933915892863831

914891862830

913890861829

912889860828

911888859827

910887858826

886857825

885856824

884855823

883854822

882853821

881852820

851819

850818

7857537216896576255935615294974654334013693373052732412091771451138149

81678475272068865662459256052849646443240036833630427224020817614411280

81578375171968765562359155952749546343139936733530327123920717514311179

81478275071868665462259055852649446243039836633430227023820617414211078

81378174971768565362158955752549346142939736533330126923720517314110977

81278074871668465262058855652449246042839636433230026823620417214010876

81177974771568365161958755552349145942739536333129926723520317113910775

81077874671468265061858655452249045842639436233029826623420217013810674

80977774571368164961758555352148945742539336132929726523320116913710573

80877674471268064861658455252048845642439236032829626423220016813610472

80777574371167964761558355151948745542339135932729526323119916713510371

80677474271067864661458255051848645442239035832629426223019816613410270

80577374170967764561358154951748545342138935732529326122919716513310169

80477274070867664461258054851648445242038835632429226022819616413210068

8037717397076756436115795475154834514193873553232912592271951631319967

8027707387066746426105785465144824504183863543222902582261941621309866

8017697377056736416095775455134814494173853533212892572251931611299765

8007687367046726406085765445124804484163843523202882562241921601289664

7997677357036716396075755435114794474153833513192872552231911591279563

7987667347026706386065745425104784464143823503182862542221901581269462

7977657337016696376055735415094774454133813493172852532211891571259361

7967647327006686366045725405084764444123803483162842522201881561249260

7957637316996676356035715395074754434113793473152832512191871551239159

794762730698665A6346025705385064744424103783463142822502181861541229058

7937617296976656336015695375054734414093773453132812492171851531218957

7927607286966646326005685365044724404083763443122802482161841521208856

7917597276956636315995675355034714394073753433112792472151831511198755

7907587266946626305985665345024704384063743423102782462141821501188654

7897577256936616295975655335014694374053733413092772452131811491178553

7887567246926606285965645325004684364043723403082762442121801481168452

7877557236916596275955635314994674354033713393072752432111791471158351

7867547226906586265945625304984664344023703383062742422101781461148250

C

EM

ETER

Y R

O

AD

A

SECTION

PPC

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h:

y

:\1

\1 m ar io n nc ne w la nd e xp an si on c iv il\

_0 ca d fil es s he et s\

1_ c_ la yo ut c oo rd in at io n se ct io n

.d w eb ro dm ar kl d:

8/

/2

:0 lo t:8 /1

5/

0:

A M

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

TECHNOLOGY:

IMEG

11044 RESEARCH BLVD.

A-230

AUSTIN, TX 78759

309.786.5092

JAYSON STICKROD, PE

Project Director

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 17101

MARION NATIONAL CEMETERY

NEW LAND EXPANSION

817CM3025

OCTOBER 30, 2024

1700 E 38TH ST, MARION, IN 46953

Date:

IRRIGATION:

EC DESIGN GROUP, LTD

400 5TH STREET

WEST DES MOINES, IA 50265

515.225.6365

ERIK CHRISTIANSEN, ASIC

GEOTECHNICAL:

TERRACON

7770 WEST NEW YORK ST.

INDIANAPOLIS, IN 46214

317.746.7925

RICHARD D. OLSON, PE

COST ESTIMATING:

TOTAL COST MANAGEMENT, LLC

13602 DULUTH DRIVE

APPLE VALLEY, MN 55124

515.244.1166

BRYAN BERTRAND OF 266

KEY MAP

BID DOCUMENTS

BID DOCUMENTSI HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED

BY ME OR UNDER MY DIRECT SUPERVISION

AND THAT I AM A DULY LICENSED

PROFESSIONAL ENGINEER UNDER THE LAWS

OF THE STATE OF MINNESOTA.

DATE: LICENSE #

SIGNATURE

PRINT NAME

EDWIN J. Y. BRODMARKLE, PE

5540910/30/2024 Addendum 01 08/20/20251

1 PPC SECTION 16 GRAVESITE NUMBERING PLAN

SCALE: 1" = 10'

SECTION 16 NUMBERING PLAN

CJ404

N

PROPERTY LIMITS

NEW PRE-PLACED CRYPT (3'x8')

NEW PERIMETER PRE-PLACED

CRYPT (3'X8')

NEW IN-GROUND CREMAIN (4'x4')

HEADSTONE DIRECTION

FLOWER WATERING STATION

SEE DETAIL 2/LK503

LEGEND

BURIAL TYPE QUANTITY

PRE-PLACED CRYPTS 973

GRAVESITE SUMMARY

0 10' 20'GRAVESITE LAYOUT NOTES - GENERAL

1. SITE LAYOUT DIMENSIONS SHOWN ARE COMPUTER (AUTOCAD) GENERATED FROM ORIGINAL

ELECTRONIC SURVEY DRAWINGS. CONTRACTOR SHALL FIELD VERIFY LAYOUT DIMENSIONS PRIOR AND DURING CONSTRUCTION. NOTIFY COR IF FIELD LAYOUT DIMENSION VARY FROM PLAN BY MORE

THAN 0.5 FEET.

2. CONTRACTOR SHALL CONTACT THE COR REGARDING ANY DISCREPANCIES BETWEEN FIELD

CONDITIONS AND PLANS PRIOR TO PROCEEDING WITH WORK. THE WRITTEN DIMENSION SHALL

SUPERSEDE THE DRAWN DIMENSION. ALL FIELD ADJUSTMENTS MUST BE APPROVED BY THE COR

PRIOR TO INSTALLATION.

3. ALL DIMENSIONS ARE TO BACK OF CURB, BACK OF WALK, OR CENTER LINE OR EDGE OF PAVING, UNLESS OTHERWISE NOTED. ALL DIMENSIONS ARE AT 90 DEGREES, UNLESS OTHERWISE NOTED.

4. IF DISCREPANCIES OCCUR IN FIELD BETWEEN THIS SET OF DRAWINGS AND FIELD CONDITIONS, THE

CONTRACTOR SHALL CONTACT THE COR TO REVIEW PRIOR TO CONSTRUCTION.

5. ALL ELEMENTS TO BE INSTALLED PER PLAN DETAILS AND MANUFACTURER'S RECOMMENDATION.

6. CONTRACTOR RESPONSIBLE FOR OBTAINING ALL NECESSARY CONSTRUCTION PERMITS TO CARRY OUT ENTIRE PROJECT. PERMITS SHALL BE IN PLACE PRIOR TO ANY CONSTRUCTION ACTIVITIES.

NOTIFY APPROPRIATE UTILITY COMPANY OF ANY AND ALL PROPOSED WORK.

7. TYPICAL SPACE FOR EACH PRE-PLACED CRYPT IS 3'-0" x 8'-0". PRECAST CRYPT IS INTENDED TO BE

CENTERED WITHIN EACH GRAVE SPACE.

8. TYPICAL SPACE FOR EACH IN-GROUND CREMAIN IS INTENDED TO BE 4'-0" x 4'-0".

EB SB 26

48.00 48.00 48.00

214 215 216 217

220 221 222 223 224

226 227 228 229 230

218 219

231 232

C

EM

ETER

Y R

O

AD

A

.5

' T

YP

48.0' TYP.

.5

' T

YP

48.00' 48' TYP. 32'

48.0' TYP. 48.0' TYP. 48.0' TYP. 24'

SECTION

PPC

GRAVESITE GRID POINTS

PT ID

ELEV

836.067

836.792

837.516

838.241

838.965

839.328

835.038

835.763

836.488

837.213

837.937

838.662

833.982

834.732

835.457

836.182

836.907

837.632

838.615

NORTHING

1921180.4151

1921180.4151

1921180.4151

1921180.4151

1921180.4151

1921180.4151

1921125.9151

1921125.9151

1921125.9151

1921125.9151

1921125.9151

1921125.9151

1921071.4151

1921071.4151

1921071.4151

1921071.4151

1921071.4151

1921071.4151

1921071.4151

EASTING

337402.7683

337450.7683

337498.7683

337546.7683

337594.7683

337618.7782

337402.7683

337450.7683

337498.7683

337546.7683

337594.7683

337642.7683

337402.7683

337450.7683

337498.7683

337546.7683

337594.7683

337642.7683

337674.7894

SECTION MARKERS

PT ID

ELEV

0.000

0.000

NORTHING

1921175.1666

1921076.6666

EASTING

337395.0198

337401.5426

835.793

833.380

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h:

y

:\1

\1 m ar io n nc ne w la nd e xp an si on c iv il\

_0 ca d fil es s he et s\

1_ c_ la yo ut c oo rd in at io n se ct io n

.d w eb ro dm ar kl d:

8/

/2

:0 lo t:8 /1

5/

0:

A M

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

TECHNOLOGY:

IMEG

11044 RESEARCH BLVD.

A-230

AUSTIN, TX 78759

309.786.5092

JAYSON STICKROD, PE

Project Director

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 17101

MARION NATIONAL CEMETERY

NEW LAND EXPANSION

817CM3025

OCTOBER 30, 2024

1700 E 38TH ST, MARION, IN 46953

Date:

IRRIGATION:

EC DESIGN GROUP, LTD

400 5TH STREET

WEST DES MOINES, IA 50265

515.225.6365

ERIK CHRISTIANSEN, ASIC

GEOTECHNICAL:

TERRACON

7770 WEST NEW YORK ST.

INDIANAPOLIS, IN 46214

317.746.7925

RICHARD D. OLSON, PE

COST ESTIMATING:

TOTAL COST MANAGEMENT, LLC

13602 DULUTH DRIVE

APPLE VALLEY, MN 55124

515.244.1166

BRYAN BERTRAND OF 266

KEY MAP

BID DOCUMENTS

BID DOCUMENTSI HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED

BY ME OR UNDER MY DIRECT SUPERVISION

AND THAT I AM A DULY LICENSED

PROFESSIONAL ENGINEER UNDER THE LAWS

OF THE STATE OF MINNESOTA.

DATE: LICENSE #

SIGNATURE

PRINT NAME

EDWIN J. Y. BRODMARKLE, PE

5540910/30/2024 Addendum 01 08/20/20251

1 PPC SECTION 16 GRAVESITE LAYOUT PLAN

SCALE: 1" = 10'

GRAVESITE LAYOUT NOTES - GENERAL

1. SITE LAYOUT DIMENSIONS SHOWN ARE COMPUTER (AUTOCAD) GENERATED FROM ORIGINAL

ELECTRONIC SURVEY DRAWINGS. CONTRACTOR SHALL FIELD VERIFY LAYOUT DIMENSIONS PRIOR AND DURING CONSTRUCTION. NOTIFY COR IF FIELD LAYOUT DIMENSION VARY FROM PLAN BY MORE

THAN 0.5 FEET.

2. CONTRACTOR SHALL CONTACT THE COR REGARDING ANY DISCREPANCIES BETWEEN FIELD

CONDITIONS AND PLANS PRIOR TO PROCEEDING WITH WORK. THE WRITTEN DIMENSION SHALL

SUPERSEDE THE DRAWN DIMENSION. ALL FIELD ADJUSTMENTS MUST BE APPROVED BY THE COR

PRIOR TO INSTALLATION.

3. ALL DIMENSIONS ARE TO BACK OF CURB, BACK OF WALK, OR CENTER LINE OR EDGE OF PAVING, UNLESS OTHERWISE NOTED. ALL DIMENSIONS ARE AT 90 DEGREES, UNLESS OTHERWISE NOTED.

4. IF DISCREPANCIES OCCUR IN FIELD BETWEEN THIS SET OF DRAWINGS AND FIELD CONDITIONS, THE

CONTRACTOR SHALL CONTACT THE COR TO REVIEW PRIOR TO CONSTRUCTION.

5. ALL ELEMENTS TO BE INSTALLED PER PLAN DETAILS AND MANUFACTURER'S RECOMMENDATION.

6. CONTRACTOR RESPONSIBLE FOR OBTAINING ALL NECESSARY CONSTRUCTION PERMITS TO CARRY OUT ENTIRE PROJECT. PERMITS SHALL BE IN PLACE PRIOR TO ANY CONSTRUCTION ACTIVITIES.

NOTIFY APPROPRIATE UTILITY COMPANY OF ANY AND ALL PROPOSED WORK.

7. TYPICAL SPACE FOR EACH PRE-PLACED CRYPT IS 3'-0" x 8'-0". PRECAST CRYPT IS INTENDED TO BE

CENTERED WITHIN EACH GRAVE SPACE.

8. TYPICAL SPACE FOR EACH IN-GROUND CREMAIN IS INTENDED TO BE 4'-0" x 4'-0".

SECTION 16 LAYOUT PLAN

CJ405

N

PROPERTY LIMITS

NEW PRE-PLACED CRYPT (3'x8')

NEW PERIMETER PRE-PLACED CRYPT

(3'X8') NEW IN-GROUND CREMAIN (4'x4')

HEADSTONE DIRECTION

GRID MONUMENT SEE DETAIL 4/CJ501

SECTION MARKER SEE DETAIL 1/LK502

GRID LINE

FLOWER WATERING STATION SEE

DETAIL 2/LK503

LEGEND

0 10' 20'

EB SB 27

214 215 216 217

220 221 222 223 224

226 227 228 229 230

218 219

231 232

C

EM

ETER

Y R

O

AD

A

CO

CO

CO-4

RIM 839.09

NV 831.34

CO-5

RIM 838.51

NV 830.76

FW

SECTION

PPC

CBMH-403

RIM 834.20

NV 825.68

CBMH-401

RIM 833.76

NV 824.60

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h:

y

:\1

\1 m ar io n nc ne w la nd e xp an si on c iv il\

_0 ca d fil es s he et s\

1_ c_ la yo ut c oo rd in at io n se ct io n

.d w eb ro dm ar kl d:

8/

/2

:0 lo t:8 /1

5/

0:

A M

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

TECHNOLOGY:

IMEG

11044 RESEARCH BLVD.

A-230

AUSTIN, TX 78759

309.786.5092

JAYSON STICKROD, PE

Project Director

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 17101

MARION NATIONAL CEMETERY

NEW LAND EXPANSION

817CM3025

OCTOBER 30, 2024

1700 E 38TH ST, MARION, IN 46953

Date:

IRRIGATION:

EC DESIGN GROUP, LTD

400 5TH STREET

WEST DES MOINES, IA 50265

515.225.6365

ERIK CHRISTIANSEN, ASIC

GEOTECHNICAL:

TERRACON

7770 WEST NEW YORK ST.

INDIANAPOLIS, IN 46214

317.746.7925

RICHARD D. OLSON, PE

COST ESTIMATING:

TOTAL COST MANAGEMENT, LLC

13602 DULUTH DRIVE

APPLE VALLEY, MN 55124

515.244.1166

BRYAN BERTRAND OF 266

KEY MAP

BID DOCUMENTS

BID DOCUMENTSI HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED

BY ME OR UNDER MY DIRECT SUPERVISION

AND THAT I AM A DULY LICENSED

PROFESSIONAL ENGINEER UNDER THE LAWS

OF THE STATE OF MINNESOTA.

DATE: LICENSE #

SIGNATURE

PRINT NAME

EDWIN J. Y. BRODMARKLE, PE

5540910/30/2024 Addendum 01 08/20/20251

1 PPC SECTION 16 GRAVESITE COORDINATION PLAN

SCALE: 1" = 10'

SECTION 16 COORDINATION PLAN

CJ406

N

0 10' 20'

PROPERTY LIMITS

NEW PRE-PLACED CRYPT (3'x8')

NEW PERIMETER PRE-PLACED CRYPT

(3'X8') NEW IN-GROUND CREMAIN (4'x4')

HEADSTONE DIRECTION

GRID MONUMENT SEE DETAIL 4/CJ501

SECTION MARKER SEE DETAIL 1/LK502

STRUCTURE RIM & INVERT ELEVATION

IRRIGATION VALVE

IRRIGATION HEAD

NEW STORM STRUCTURES

IRRIGATION PIPE MAIN

IRRIGATION PIPE LATERAL

IRRIGATION COMM LINE

IRRIGATION RE-ENTERABLE

CONNECTOR

IRRIGATION SURGE PROTECTOR

FLOWER WATERING STATION SEE

DETAIL 2/LK503

PROPOSED DRAINTILE SEE DETAILS

2&3/CJ501

PROPOSED DRAINTILE CLEANOUT SEE

DETAIL 1/CJ501

LEGEND

SMH-205

RIM 836.79

INV 821.72

INV 821.68

EB SB 28

KEY NOTES

1 1 1 1 1 1

1 1 1 1 1 1

ROUTE IRRIGATION LINE AROUND GRID

MONUMENT AND SECTION MARKER

FOUNDATIONS, IRRIGATION LINE SHALL

NOT IMPEDE ON BURIAL SECTIONS.

CONTRACTOR TO STAKE ALL GRID

MONUMENT, SECTION MARKER, AND

SITE ELEMENT LOCATIONS PRIOR TO

INSTALLATION OF IRRIGATION TO AVOID

CONFLICTS.

CO

896864832800768736704672640608576544512480448416384352320288256224192161133107836243271451

970949922890858826794762730698665A634602570538506474442410378346314282250218187159 997986

969948921889857825793761729697665633601569537505473441409377345313281249217186158 996985

968947920888856824792760728696664632600568536504472440408376344312280248216185157131 995984

967946919887855823791759727695663631599567535503471439407375343311279247215184156130 994983

966945918886854822790758726694662630598566534502470438406374342310278246214183155129 993982

965944917885853821789757725693661629597565533501469437405373341309277245213182154128104 992981

964943916884852820788756724692660628596564532500468436404372340308276244212181153127103 980

96394291588385181978775572369165962759556353149946743540337133930727524321118015212610281 979

96294191488285081878675472269065862659456253049846643440237033830627424221017915112510180 978

96194091388184981778575372168965762559356152949746543340136933730527324120917815012410079 977

960939912880848816784752720688656624592560528496464432400368336304272240208177149123997859 976

95993891187984781578375171968765562359155952749546343139936733530327123920717614812298775842

95893791087884681478275071868665462259055852649446243039836633430227023820617514712197765741

95793690987784581378174971768565362158955752549346142939736533330126923720517414612096755640

9569359088768448127807487166846526205885565244924604283963643323002682362041731451199574553926

9559349078758438117797477156836516195875555234914594273953633312992672352031721441189473543825

9339068748428107787467146826506185865545224904584263943623302982662342021711431179372533724

9329058738418097777457136816496175855535214894574253933613292972652332011701421169271523623

931904872840808776744712680648616584552520488456424392360328296264232200169141115917051352213

930903871839807775743711679647615583551519487455423391359327295263231199168140114906950342112

929902870838806774742710678646614582550518486454422390358326294262230198167139113896849332011

928901869837805773741709677645613581549517485453421389357325293261229197166138112886748321910

90086883680477274070867664461258054851648445242038835632429226022819616513711187664731189

899867835803771739707675643611579547515483451419387355323291259227195164136110866546301784

898866834802770738706674642610578546514482450418386354322290258226194163135109856445291673

897865833801769737705673641609577545513481449417385353321289257225193162134108846344281562

975954927895863831799767735703671639607575543511479447415383351319287255223 10081002991

974953926894862830798766734702670638606574542510478446414382350318286254222191 10071001990

973952925893861829797765733701669637605573541509477445413381349317285253221190 10061000989

972951924892860828796764732700668636604572540508476444412380348316284252220189 1005999988

971950923891859827795763731699667635603571539507475443411379347315283251219188160 987 1004998

INDIANA AVENUE

CEMETERY ROAD A

SECTION

PPC

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h:

y

:\1

\1 m ar io n nc ne w la nd e xp an si on c iv il\

_0 ca d fil es s he et s\

1_ c_ la yo ut c oo rd in at io n se ct io n

.d w eb ro dm ar kl d:

8/

/2

:0 lo t:8 /1

5/

0:

A M

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

TECHNOLOGY:

IMEG

11044 RESEARCH BLVD.

A-230

AUSTIN, TX 78759

309.786.5092

JAYSON STICKROD, PE

Project Director

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 17101

MARION NATIONAL CEMETERY

NEW LAND EXPANSION

817CM3025

OCTOBER 30, 2024

1700 E 38TH ST, MARION, IN 46953

Date:

IRRIGATION:

EC DESIGN GROUP, LTD

400 5TH STREET

WEST DES MOINES, IA 50265

515.225.6365

ERIK CHRISTIANSEN, ASIC

GEOTECHNICAL:

TERRACON

7770 WEST NEW YORK ST.

INDIANAPOLIS, IN 46214

317.746.7925

RICHARD D. OLSON, PE

COST ESTIMATING:

TOTAL COST MANAGEMENT, LLC

13602 DULUTH DRIVE

APPLE VALLEY, MN 55124

515.244.1166

BRYAN BERTRAND OF 266

KEY MAP

BID DOCUMENTS

BID DOCUMENTSI HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED

BY ME OR UNDER MY DIRECT SUPERVISION

AND THAT I AM A DULY LICENSED

PROFESSIONAL ENGINEER UNDER THE LAWS

OF THE STATE OF MINNESOTA.

DATE: LICENSE #

SIGNATURE

PRINT NAME

EDWIN J. Y. BRODMARKLE, PE

5540910/30/2024 Addendum 01 08/20/20251

1 PPC SECTION 17 GRAVESITE NUMBERING PLAN

SCALE: 1" = 10'

SECTION 17 NUMBERING PLAN

CJ407

N

PROPERTY LIMITS

NEW PRE-PLACED CRYPT (3'x8')

NEW PERIMETER PRE-PLACED

CRYPT (3'X8')

NEW IN-GROUND CREMAIN (4'x4')

HEADSTONE DIRECTION

FLOWER WATERING STATION

SEE DETAIL 3/LK503

LEGEND

BURIAL TYPE QUANTITY

PRE-PLACED CRYPTS 1008

GRAVESITE SUMMARY

0 10' 20'

GRAVESITE LAYOUT NOTES - GENERAL

1. SITE LAYOUT DIMENSIONS SHOWN ARE COMPUTER (AUTOCAD) GENERATED FROM ORIGINAL

ELECTRONIC SURVEY DRAWINGS. CONTRACTOR SHALL FIELD VERIFY LAYOUT DIMENSIONS PRIOR AND DURING CONSTRUCTION. NOTIFY COR IF FIELD LAYOUT DIMENSION VARY FROM PLAN BY MORE

THAN 0.5 FEET.

2. CONTRACTOR SHALL CONTACT THE COR REGARDING ANY DISCREPANCIES BETWEEN FIELD

CONDITIONS AND PLANS PRIOR TO PROCEEDING WITH WORK. THE WRITTEN DIMENSION SHALL

SUPERSEDE THE DRAWN DIMENSION. ALL FIELD ADJUSTMENTS MUST BE APPROVED BY THE COR

PRIOR TO INSTALLATION.

3. ALL DIMENSIONS ARE TO BACK OF CURB, BACK OF WALK, OR CENTER LINE OR EDGE OF PAVING, UNLESS OTHERWISE NOTED. ALL DIMENSIONS ARE AT 90 DEGREES, UNLESS OTHERWISE NOTED.

4. IF DISCREPANCIES OCCUR IN FIELD BETWEEN THIS SET OF DRAWINGS AND FIELD CONDITIONS, THE

CONTRACTOR SHALL CONTACT THE COR TO REVIEW PRIOR TO CONSTRUCTION.

5. ALL ELEMENTS TO BE INSTALLED PER PLAN DETAILS AND MANUFACTURER'S RECOMMENDATION.

6. CONTRACTOR RESPONSIBLE FOR OBTAINING ALL NECESSARY CONSTRUCTION PERMITS TO CARRY OUT ENTIRE PROJECT. PERMITS SHALL BE IN PLACE PRIOR TO ANY CONSTRUCTION ACTIVITIES.

NOTIFY APPROPRIATE UTILITY COMPANY OF ANY AND ALL PROPOSED WORK.

7. TYPICAL SPACE FOR EACH PRE-PLACED CRYPT IS 3'-0" x 8'-0". PRECAST CRYPT IS INTENDED TO BE

CENTERED WITHIN EACH GRAVE SPACE.

8. TYPICAL SPACE FOR EACH IN-GROUND CREMAIN IS INTENDED TO BE 4'-0" x 4'-0".

EB SB 29

226 227 228 229 230

233 234 235 236 237

239 240 241 242

231 232

243 244

48.0' TYP. 48.0' TYP. 48.0' TYP. 48.0' TYP. 32.0'

.5

.1

INDIANA AVENUE

CEMETERY ROAD A

48.0' TYP. 48.0' TYP. 32.0'

SECTION

PPC

48.0' 48.0'

48.0' TYP.

GRAVESITE GRID POINTS

PT ID

ELEV

833.982

834.732

835.457

836.182

836.907

837.632

838.615

833.397

834.122

834.845

835.570

836.295

837.020

832.846

833.569

834.294

835.019

835.742

837.769

NORTHING

1921071.4151

1921071.4151

1921071.4151

1921071.4151

1921071.4151

1921071.4151

1921071.4151

1921016.9151

1921016.9151

1921016.9151

1921016.9151

1921016.9151

1921016.9151

1920965.8615

1920965.8615

1920965.8615

1920965.8615

1920965.8080

1920965.8615

EASTING

337402.7683

337450.7683

337498.7683

337546.7683

337594.7683

337642.7683

337674.7894

337450.7683

337498.7683

337546.7683

337594.7683

337642.7683

337690.7683

337498.7683

337546.7683

337594.7683

337642.7683

337690.7683

337722.7951

SECTION MARKERS

PT ID

ELEV

0.000

0.000

0.000

NORTHING

1921066.1676

1920967.6675

1920952.1214

EASTING

337404.7554

337480.8218

337722.5183

832.728

831.319

836.579

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h:

y

:\1

\1 m ar io n nc ne w la nd e xp an si on c iv il\

_0 ca d fil es s he et s\

1_ c_ la yo ut c oo rd in at io n se ct io n

.d w eb ro dm ar kl d:

8/

/2

:0 lo t:8 /1

5/

0:

A M

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

TECHNOLOGY:

IMEG

11044 RESEARCH BLVD.

A-230

AUSTIN, TX 78759

309.786.5092

JAYSON STICKROD, PE

Project Director

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 17101

MARION NATIONAL CEMETERY

NEW LAND EXPANSION

817CM3025

OCTOBER 30, 2024

1700 E 38TH ST, MARION, IN 46953

Date:

IRRIGATION:

EC DESIGN GROUP, LTD

400 5TH STREET

WEST DES MOINES, IA 50265

515.225.6365

ERIK CHRISTIANSEN, ASIC

GEOTECHNICAL:

TERRACON

7770 WEST NEW YORK ST.

INDIANAPOLIS, IN 46214

317.746.7925

RICHARD D. OLSON, PE

COST ESTIMATING:

TOTAL COST MANAGEMENT, LLC

13602 DULUTH DRIVE

APPLE VALLEY, MN 55124

515.244.1166

BRYAN BERTRAND OF 266

KEY MAP

BID DOCUMENTS

BID DOCUMENTSI HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED

BY ME OR UNDER MY DIRECT SUPERVISION

AND THAT I AM A DULY LICENSED

PROFESSIONAL ENGINEER UNDER THE LAWS

OF THE STATE OF MINNESOTA.

DATE: LICENSE #

SIGNATURE

PRINT NAME

EDWIN J. Y. BRODMARKLE, PE

5540910/30/2024 Addendum 01 08/20/20251

1 PPC SECTION 17 GRAVESITE LAYOUT PLAN

SCALE: 1" = 10'

GRAVESITE LAYOUT NOTES - GENERAL

1. SITE LAYOUT DIMENSIONS SHOWN ARE COMPUTER (AUTOCAD) GENERATED FROM ORIGINAL

ELECTRONIC SURVEY DRAWINGS. CONTRACTOR SHALL FIELD VERIFY LAYOUT DIMENSIONS PRIOR AND DURING CONSTRUCTION. NOTIFY COR IF FIELD LAYOUT DIMENSION VARY FROM PLAN BY MORE

THAN 0.5 FEET.

2. CONTRACTOR SHALL CONTACT THE COR REGARDING ANY DISCREPANCIES BETWEEN FIELD

CONDITIONS AND PLANS PRIOR TO PROCEEDING WITH WORK. THE WRITTEN DIMENSION SHALL

SUPERSEDE THE DRAWN DIMENSION. ALL FIELD ADJUSTMENTS MUST BE APPROVED BY THE COR

PRIOR TO INSTALLATION.

3. ALL DIMENSIONS ARE TO BACK OF CURB, BACK OF WALK, OR CENTER LINE OR EDGE OF PAVING, UNLESS OTHERWISE NOTED. ALL DIMENSIONS ARE AT 90 DEGREES, UNLESS OTHERWISE NOTED.

4. IF DISCREPANCIES OCCUR IN FIELD BETWEEN THIS SET OF DRAWINGS AND FIELD CONDITIONS, THE

CONTRACTOR SHALL CONTACT THE COR TO REVIEW PRIOR TO CONSTRUCTION.

5. ALL ELEMENTS TO BE INSTALLED PER PLAN DETAILS AND MANUFACTURER'S RECOMMENDATION.

6. CONTRACTOR RESPONSIBLE FOR OBTAINING ALL NECESSARY CONSTRUCTION PERMITS TO CARRY OUT ENTIRE PROJECT. PERMITS SHALL BE IN PLACE PRIOR TO ANY CONSTRUCTION ACTIVITIES.

NOTIFY APPROPRIATE UTILITY COMPANY OF ANY AND ALL PROPOSED WORK.

7. TYPICAL SPACE FOR EACH PRE-PLACED CRYPT IS 3'-0" x 8'-0". PRECAST CRYPT IS INTENDED TO BE

CENTERED WITHIN EACH GRAVE SPACE.

8. TYPICAL SPACE FOR EACH IN-GROUND CREMAIN IS INTENDED TO BE 4'-0" x 4'-0".

SECTION 17 LAYOUT PLAN

CJ408

N

PROPERTY LIMITS

NEW PRE-PLACED CRYPT (3'x8')

NEW PERIMETER PRE-PLACED CRYPT

(3'X8') NEW IN-GROUND CREMAIN (4'x4')

HEADSTONE DIRECTION

GRID MONUMENT SEE DETAIL 4/CJ501

SECTION MARKER SEE DETAIL 1/LK502

GRID LINE

FLOWER WATERING STATION SEE DETAIL

2/LK503

LEGEND

0 10' 20'

EB SB 30

226 227 228 229 230

233 234 235 236 237

239 240 241 242

231 232

243 244

INDIANA AVENUE

CO

CO

CO

CBMH-109

RIM 835.78

INV 831.33

INV 831.13

CBMH-108

RIM 833.15

INV 827.00 (12" IN)

INV 826.80 (12" OUT)

INV 829.71 (12" IN)

CO-8

RIM 836.29

INV 828.54

CEMETERY ROAD A

CB-110

RIM 835.85

INV 831.85

FW

SECTION

PPC

CBMH-107

RIM 832.02

INV 825.97

INV 825.77

CB-301

RIM 831.80

INV 828.30

CO-6

RIM 837.78

INV 830.03

CO-7

RIM 836.90

INV 829.15

CBMH-302

RIM 832.43

INV 824.55

INV 828.16

INV 824.81

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h:

y

:\1

\1 m ar io n nc ne w la nd e xp an si on c iv il\

_0 ca d fil es s he et s\

1_ c_ la yo ut c oo rd in at io n se ct io n

.d w eb ro dm ar kl d:

8/

/2

:0 lo t:8 /1

5/

0:

A M

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

TECHNOLOGY:

IMEG

11044 RESEARCH BLVD.

A-230

AUSTIN, TX 78759

309.786.5092

JAYSON STICKROD, PE

Project Director

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 17101

MARION NATIONAL CEMETERY

NEW LAND EXPANSION

817CM3025

OCTOBER 30, 2024

1700 E 38TH ST, MARION, IN 46953

Date:

IRRIGATION:

EC DESIGN GROUP, LTD

400 5TH STREET

WEST DES MOINES, IA 50265

515.225.6365

ERIK CHRISTIANSEN, ASIC

GEOTECHNICAL:

TERRACON

7770 WEST NEW YORK ST.

INDIANAPOLIS, IN 46214

317.746.7925

RICHARD D. OLSON, PE

COST ESTIMATING:

TOTAL COST MANAGEMENT, LLC

13602 DULUTH DRIVE

APPLE VALLEY, MN 55124

515.244.1166

BRYAN BERTRAND OF 266

KEY MAP

BID DOCUMENTS

BID DOCUMENTSI HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED

BY ME OR UNDER MY DIRECT SUPERVISION

AND THAT I AM A DULY LICENSED

PROFESSIONAL ENGINEER UNDER THE LAWS

OF THE STATE OF MINNESOTA.

DATE: LICENSE #

SIGNATURE

PRINT NAME

EDWIN J. Y. BRODMARKLE, PE

5540910/30/2024 Addendum 01 08/20/20251

1 PPC SECTION 17 GRAVESITE COORDINATION PLAN

SCALE: 1" = 10'

N

0 10' 20'

SECTION 17 COORDINATION PLAN

CJ409

PROPERTY LIMITS

NEW PRE-PLACED CRYPT (3'x8')

NEW PERIMETER PRE-PLACED CRYPT

(3'X8') OVERSIZED CRYPT (4'x10') NEW IN-GROUND CREMAIN (4'x4')

HEADSTONE DIRECTION

GRID MONUMENT SEE DETAIL 4/CJ501

SECTION MARKER SEE DETAIL 1/LK502

STRUCTURE RIM & INVERT ELEVATION

IRRIGATION VALVE

IRRIGATION HEAD

NEW STORM STRUCTURES

UNDERGROUND ELECTRIC

IRRIGATION PIPE MAIN

IRRIGATION PIPE LATERAL

IRRIGATION COMM LINE

IRRIGATION RE-ENTERABLE

CONNECTOR

IRRIGATION SURGE PROTECTOR

FLOWER WATERING STATION SEE

DETAIL 2/LK503

PROPOSED DRAINTILE SEE DETAILS

2&3/CJ501

PROPOSED DRAINTILE CLEANOUT SEE

DETAIL 1/CJ501

LEGEND

SMH-205

RIM 836.79

INV 821.72

INV 821.68

EB SB 31

KEY NOTES

1 ROUTE IRRIGATION LINE AROUND GRID

MONUMENT AND SECTION MARKER

FOUNDATIONS, IRRIGATION LINE SHALL

NOT IMPEDE ON BURIAL SECTIONS.

CONTRACTOR TO STAKE ALL GRID

MONUMENT, SECTION MARKER, AND

SITE ELEMENT LOCATIONS PRIOR TO

INSTALLATION OF IRRIGATION TO AVOID

CONFLICTS.

1 1 1 1 1 1

11111

CO

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h:

y

:\1

\1 m ar io n nc ne w la nd e xp an si on c iv il\

_0 ca d fil es s he et s\

1_ c_ s ite d et ai ls

.d w eb ro dm ar kl d:

8/

/2

:4 lo t:8

/1 5/

0:

A

M

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

TECHNOLOGY:

IMEG

11044 RESEARCH BLVD.

A-230

AUSTIN, TX 78759

309.786.5092

JAYSON STICKROD, PE

Project Director

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 17101

MARION NATIONAL CEMETERY

NEW LAND EXPANSION

817CM3025

OCTOBER 30, 2024

1700 E 38TH ST, MARION, IN 46953

Date:

IRRIGATION:

EC DESIGN GROUP, LTD

400 5TH STREET

WEST DES MOINES, IA 50265

515.225.6365

ERIK CHRISTIANSEN, ASIC

GEOTECHNICAL:

TERRACON

7770 WEST NEW YORK ST.

INDIANAPOLIS, IN 46214

317.746.7925

RICHARD D. OLSON, PE

COST ESTIMATING:

TOTAL COST MANAGEMENT, LLC

13602 DULUTH DRIVE

APPLE VALLEY, MN 55124

515.244.1166

BRYAN BERTRAND OF 266

BID DOCUMENTS

BID DOCUMENTSI HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED

BY ME OR UNDER MY DIRECT SUPERVISION

AND THAT I AM A DULY LICENSED

PROFESSIONAL ENGINEER UNDER THE LAWS

OF THE STATE OF MINNESOTA.

DATE: LICENSE #

SIGNATURE

PRINT NAME

EDWIN J. Y. BRODMARKLE, PE

5540910/30/2024 Addendum 01 08/20/20251

CRYPT DETAILS

CJ501

EJYB BJN

GENERAL NOTES:

1. REINFORCED CONCRETE DESIGN, FABRICATION AND ERECTION SHALL BE IN

ACCORDANCE WITH THE AMERICAN CONCRETE INSTITUTE ACI 318-95, "BUILDING

CODE REQUIREMENTS FOR REINFORCED CONCRETE", AND SPECIFICATION SECTION

03 48 21, PRECAST CONCRETE DOUBLE DEPTH LAWN CRYPTS.

2. DESIGN LOAD REQUIREMENTS OF THE TOP LID, CRYPT BOX, AND INTERMEDIATE

SHELF: REFER TO SPECIFICATION SECTION 03 48 21, PRECAST CONCRETE DOUBLE

DEPTH LAWN CRYPTS.

3. CONTRACTOR SHALL PROVIDE DESIGN INFORMATION AND SHOP DRAWINGS FROM

PRECAST FABRICATOR FOR APPROVAL. REFER TO SPECIFICATION SECTION 03 48 21,

PRECAST CONCRETE DOUBLE DEPTH LAWN CRYPTS.

4. ALL LAWNS & IRRIGATION LINES WITHIN THE BURIAL SECTIONS SHALL BE INSTALLED

AND ACCEPTED PRIOR TO MONUMENT-BASE PLACEMENT; ALL LAWNS & IRRIGATION

LINES DAMAGED DURING INSTALLATION SHALL BE REPAIRED AT CONTRACTOR'S

EXPENSE.

5. IRRIGATION ISLES SHALL BE 3FT WIDE FOR CRYPT SECTIONS AND 4 FT WIDE FOR

IN-GROUND CREMAIN AREAS.

NOTES:

1. CENTER POINT OF BURIAL CONTROL MONUMENT GRID SHALL BE

WITHIN 0.05 FT OF THE POINT DESIGNATED ON THE PLANS.

2. CONCRETE TO EXTEND BELOW FROST DEPTH

PLAN VIEW

DETAIL ENLARGEMENT

G R

ID

LI

N E

SEE SHEET L-5.4 FOR

CRYPT INSTALLATION

AND COVER DETAILS

IRRIGATION

AISLE / SECTION

BREAK

PVC SCREW CAP, PROVIDE 2"

CLEARANCE TO CAST IRON COVER

CAST IRON CLEANOUT FRAME & COVER

LABELED C.O. OR BLANK, CAST IN CONCRETE18"X18"X6" CONCRETE

PAD OR AS SPECIFIED

FINISHED GRADE

SEE DETAIL ENLARGEMENT ABOVE

LOCATE CLEAN OUT WHERE INDICATED ON

UNDER DRAINAGE PLANS, SEE SHEET CU1011'-6"

SO

TOPSOIL

FILL. SEE DETAILS AND

SPECIFICATION

PRE-CAST CONCRETE

PRE-PLACED CRYPT

COMPACTED DRAIN ROCK - SEE SPECIFICATIONS

CORRUGATED HDPE

PERFORATED UNDERDRAIN

GASKETED PVC ELBOW MANUFACTURED

SPECIFICALLY FOR CONVERTING FROM

CORRUGATED HPE TO PVC. NYLOPLAST

FITTING BY HANCOR OR APPROVED EQUAL

NON-WOVEN CONSTRUCTION GEOSYNTHETIC.

OVERLAP 6" SEAMS UNDER DRAIN ROCK.

FABRIC LOCATED ON TOP OF SUBGRADE.

PVC PIPE REDUCER AS

REQUIRED PER PLAN

45° PVC ELBOWS (2)

4" PVC RISER, 45° ELBOWS,

AND FLUSH MOUNTED

CLEANOUT PLUG

2.0' TYPICAL

SEE UTILITY PLAN (SHEET CU-101)

FOR HORIZONTAL AND

VERTICAL LAYOUT

TOPSOIL

GRIDLINE AS SHOWN ON PLAN SHEETS

CJ402,CJ405,CJ408,CJ411, AND CJ414

COMPACTED FILL. SEE DETAILS

AND SPECIFICATIONS

STIFFENING RIBS

PRE-CAST CONCRETE LAWN CRYPT

NON-WOVEN CONSTRUCTION GEOSYNTHETIC.

OVERLAP 6" SEAMS UNDER DRAIN ROCK.

FABRIC LOCATED ON TOP OF SUBGRADE.

6" MINIMUM COMPACTED DRAIN ROCK

6" PERFORATED CORRUGATED PIPE UNDERDRAIN.

INSTALL WITH PERFORATIONS DOWN. SEE PLANS

FOR HORIZONTAL AND VERTICAL LAYOUT.

BRONZE DOMED-TOP MONUMENT MARKER

LOCATED WITHIN 4" DIA. PLACEMENT CIRCLE

4" DIA. PLACEMENT CIRCLE CENTERED ON CONCRETE MONUMENT

SLOPE CONCRETE AWAY FROM CENTER OF CONCRETE BURIAL MONUMENT

6"

3"

DOMED-TOP MONUMENT MARKET SEE DETAIL

SET FLUSH WITH FINISHED GRADE

SMOOTH TROWEL FINISH TOP SURFACE,

ENSURING POSITIVE DRANAGE

1" DIAMETER X 2 1/4" DEEP HOLE. SET MARKER WITH NON SHRINK GROUT.

6" DIAMETER, CONCRETE MONUMENT REINFORCED WITH 1 #6

REBAR, 36" LONG, 1" CLEAR FROM FACE.

BRONZE DOMED-TOP MONUMENT MARKER

WITH 3/4" DIAMETER SPLIT STYLE STEM

AND INTEGRAL LOCATION MAGNET

FIELD STAMPED CROSS HAIRS: MAX. LENGTH 3/4", MIN. LENGTH

1/2". CROSS HAIRS SHALL BE LOCATED WITHIN ENGRAVED

CIRCLE. ALIGN CROSS HAIRS WITH GRAVESITE GRID LINES.

REQUIRED 3/16" HIGH TEXT ENGRAVED ON CAP

ENGRAVED 1" DIA. CIRCLE CENTERED IN MONUMENT MARKER

2"

8" MAX. TO

TOP OF DOME

3'-6" MIN.

G R

ID

LI

N E

3'-0" O.C. 3'-0" 3'-0"

O.C.

G R

ID

LI

N E

G R

ID

LI

N E

PRECAST CONCRETE

CRYPT (TYP.)

FILL (CRYPT BACKFILL)

OVER CRYPTS

COMMON FILL IN

IRRIGATION AISLES

COMPACTED DRAIN ROCK

G R

ID

LI

N E

G R

ID

LI

N E

3'-0" O.C.

G R

ID

LI

N E

G R

ID

LI

N E

3'-0" O.C.

3'-0" O.C.

PRECAST CONCRETE

CRYPT (TYP.)

COMPACTED DRAIN ROCK

NON-WOVEN CONSTRUCTION GEOSYNTHETIC

PERFORATED CORRUGATED HDPE UNDERDRAIN PIPE

(HOLES DOWN) SURROUND WITH 6" MIN. DRAIN ROCK;

REFER TO UNDERDRAINAGE PLANS AND STORM

PLANS FOR HORIZONTAL AND VERTICAL LAYOUT AND

CONNECTION TO STORM DRAIN SYSTEM.

0.8SEE DETAILS 10 & 11/CS-502 FOR

CRYPT INSTALLATION AND COVER

DETAILS

0.86SEE DETAILS 10 & 11/CJ502 FOR

CRYPT INSTALLATION AND COVER

DETAILS

IRRIGATION LATERAL PIPE

(SEE IRRIGATION PLANS)

12"

EQ EQ

SCALE:1

DRAINAGE CLEANOUT (CRYPT)

N.T.S (30" x 42" PAPER SIZE) SCALE:2

PERIMETER CRYPT & UNDERDRAIN

N.T.S (30" x 42" PAPER SIZE) SCALE:3

CRYPT FIELD LATERAL UNDERDRAIN

N.T.S (30" x 42" PAPER SIZE)

SCALE:4

GRAVESITE MONUMENT MARKER (CAST-IN-PLACE)

N.T.S (30" x 42" PAPER SIZE) SCALE:5

CRYPT AISLE BACKFILL

N.T.S (30" x 42" PAPER SIZE)

NON-WOVEN CONSTRUCTION

GEOSYNTHETIC. OVERLAP 6" SEAMS

UNDER DRAIN ROCK. FABRIC LOCATED

ON TOP OF SUBGRADE.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h:

y

:\1

\1 m ar io n nc ne w la nd e xp an si on c iv il\

_0 ca d fil es s he et s\

1_ c_ s ite d et ai ls

.d w eb ro dm ar kl d:

8/

/2

:4 lo t:8

/1 5/

0:

A

M

Office of Design and Construction

Services

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

TECHNOLOGY:

IMEG

11044 RESEARCH BLVD.

A-230

AUSTIN, TX 78759

309.786.5092

JAYSON STICKROD, PE

Project Director

Revisions:

1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 17101

MARION NATIONAL CEMETERY

NEW LAND EXPANSION

817CM3025

OCTOBER 30, 2024

1700 E 38TH ST, MARION, IN 46953

Date:

IRRIGATION:

EC DESIGN GROUP, LTD

400 5TH STREET

WEST DES MOINES, IA 50265

515.225.6365

ERIK CHRISTIANSEN, ASIC

GEOTECHNICAL:

TERRACON

7770 WEST NEW YORK ST.

INDIANAPOLIS, IN 46214

317.746.7925

RICHARD D. OLSON, PE

COST ESTIMATING:

TOTAL COST MANAGEMENT, LLC

13602 DULUTH DRIVE

APPLE VALLEY, MN 55124

515.244.1166

BRYAN BERTRAND OF 266

BID DOCUMENTS

BID DOCUMENTSI HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS PREPARED

BY ME OR UNDER MY DIRECT SUPERVISION

AND THAT I AM A DULY LICENSED

PROFESSIONAL ENGINEER UNDER THE LAWS

OF THE STATE OF MINNESOTA.

DATE: LICENSE #

SIGNATURE

PRINT NAME

EDWIN J. Y. BRODMARKLE, PE

5540910/30/2024 Addendum 01 08/20/20251

CRYPT DETAILS

CJ502

EJYB BJN

* CONTRACTOR SHALL PROVIDE THE MEANS AND METHODS TO

VERIFY DEPTH OF COVER. DEFICIENCIES IN DEPTH (OR

EXCESSES) SHALL BE REMEDIED PRIOR TO ACCEPTANCE OF

CRYPT INSTALLATION. VARIANCE SHALL NOT EXCEED ±1" FROM

FINISH GRADE.

EQUAL

EQ

PLAN VIEW

EQ

EQ

15" (TYP)

EQUAL

4" THICK CONC. LID1'-6"

4"

90"

LIFTING LUG

2"

2"

#3 REBAR @ 101

2" O.C.

BOTH WAYS

36 PAINT GRAVE 1042 ON LID

AT HEAD OF GRAVE; 10-12"

HIGH NUMBERS (MIN.)

COR TO APPROVE PAINT

INSTALLATION METHOD

H

EA

D O

F G

R

AV

E

34"

90"

1'-6"

4"

4"

TYP.

LIFTING HANDLE

90"

86"

CASKET REST

4" MIN. HEIGHT

4"

4"Ø (AT BOTTOM) TAPERED

DRAIN HOLES (2 PLACES, TYP.)

NOTE:

CASKET RESTS TO BE 20" FROM

CENTERLINE OF CASKET EACH

WAY. VERIFY WITH

MANUFACTURER SHOP DRAWINGS.

25" MIN.

CLEAR

HEIGHT

25" MIN.

CLEAR

HEIGHT

60"

MAX.

CRYPT LID

4" CHAMFER

(ALL SIDES OF LID)

84"

31"28"

2"

2"

42"

ABS INSIDE SHELF

OR EQUIVALENT

1 12" SCH 40 PVC PIPE

OR EQUIVALENT

LIFTING

HANDLE4"

TYP.

4" 34" 21

4"

60"

MAX.

34"

25" MIN.

CLEAR

HEIGHT

25" MIN.

CLEAR

HEIGHT 30" MIN.

3"

4"

4"

CASKET RESTS

4"

4"Ø…

This is the start of the file's text. The full file is on GovTribe.