This architectural drawing package is for a proposed electrical, HVAC, and IT infrastructure upgrade project at the Iowa City VA Medical Center. The project involves demolishing existing partitions and ceilings in several rooms on the ninth floor to install new telecommunications and electrical closets. Key demolition and new construction work is shown on the floor plans. The project is identified as VA Contract Number 36C77621N281535 and is currently in the construction bid document phase.

The related federal contract opportunity is a request for proposal issued by the Department of Veterans Affairs Technology Acquisition Center Austin. The solicitation number is 36C77622R0094 and it is for design-bid-build construction services for the Iowa City EHRM Infrastructure Upgrades project. Interested offerors are invited to submit pricing and technical proposals in response to upgrade the electrical, HVAC and IT infrastructure as depicted in the architectural drawings.

View the file

Other files

File Type Posted
Amendment 0005 Attachment 2 - Brand Name Items - Johnson Control_Redacted.pdf PDF
Amendment 0005 Attachment 1 - Spec Section 260541.docx DOCX document
36C77622R0094 0005.docx DOCX document
36C77622R0094 0004.docx DOCX document
36C77622R0094 0004 - Attachment 1 - Additional RFI Responses.docx DOCX document
IMG_0087.jpg JPG image
IMG_0102.jpg JPG image
IMG_0088.jpg JPG image
IMG_0090.jpg JPG image
IMG_0092.jpg JPG image
IMG_0097.jpg JPG image
IMG_0086.jpg JPG image
IMG_0095.jpg JPG image
IMG_0099.jpg JPG image
IMG_0100.jpg JPG image
IMG_0089.jpg JPG image
IMG_0094.jpg JPG image
IMG_0091.jpg JPG image
IMG_0096.jpg JPG image
IMG_0101.jpg JPG image
36C77622R0094 0003.docx DOCX document
IMG_0085.jpg JPG image
IMG_0093.jpg JPG image
IMG_0098.jpg JPG image
Attachment 1 - RFI Answered.docx DOCX document
Attachment 2 - ICRA forms EHRM project.pdf PDF
36C77622R0094 0002.docx DOCX document
BUILDING WRAP PRODUCT DATA FOR SPEC.docx DOCX document
RackHat_V1-1.pdf PDF
HDPE LUMBER PRODUCT DATA FOR SPEC.docx DOCX document
VINYL RACK HAT PRODUCT DATA FOR SPEC.docx DOCX document
RFIs FROM GCs Resp All Disciplines 07 06 22.docx DOCX document
North American Fiberboard Association.pdf PDF
GEOFOAM PRODUCT DATA FOR SPEC.docx DOCX document
STRUCTURAL FIBERBOARD SHEATHING PRODUCT DATA FOR SPEC.docx DOCX document
Attachment 2 - Site Visit Sign in Sheet 6.9.22.pdf PDF
Attachment 3 - Bandcroft addendum 1.docx DOCX document
Attachment 5 - 105 - 01-ET409EP ADD 1.pdf PDF
Attachment 8 - 246_01-FX409 ADD 1.pdf PDF
Attachment 4 - 88 - 01-ET109RP ADD 1.pdf PDF
Attachment 6 - 159 - 01-409-RSP ADD 1.pdf PDF
Attachment 10 - 282_01-E409 ADD 1.pdf PDF
36C77622R0094 0001.docx DOCX document
Attachment 9 - 264_01-M415 ADD 1.pdf PDF
Attachment 1 - Geotechnical Engineering Report.pdf PDF
Attachment 8 - 636A821700_BID 20220408 Dwgs_Part6.pdf PDF
Attachment 9 - 636A821700_BID 20220408 Dwgs_Part7.pdf PDF
Attachment 16 - VA 6500.6 Appendix C.pdf PDF
Attachment 15 - VA Notice of Limitations on Subcontracting-Certificate of Compliance.docx DOCX document
Attachment 2 - 636A821700_BID 20220408 Spec V2.pdf PDF
Show 40 more

Latest 50 of 62 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ARCHITECTURAL - ENLARGED FLOOR

PLAN - BUILDING 01 - NINTH FLOOR

XX XX 01- A409

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

K C

C G

P

R O

J E

C T

S

C

D

V

I S

N

I D

I Q

N o r t h

D a k o t a

I o w a C

R

E

H R

M

I o w a

C i t y

I A

D e s D o c s

D r a w i n g s W

O R

K I N

G A

C A

D C

A d w g

P

M

CONSTRUCTION BID

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

EHRM INFRASTRUCTURE

UPGRADES

IOWA CITY, IA

636A8-21-700

Project Director

Revisions: Date:

www. bancroft-ae.com

BAE PROJECT NO. 18-121

3300 Dundee Rd. Suite D Northbrook, IL 60062

T: 847.952.9362

VA CONTRACT NO. 36C77621N281535% SCHEMATIC DESIGN SUBMISSION 07-15-21

75% DESIGN DEVELOPMENT SUBMISSION 08-19-21

95% CONSTRUCTION DOCUMENTS SUBMISSION 10-21-21

100% CONSTRUCTION DOCUMENTS SUBMISSION 11-09-21

CONSTRUCTION BID DOCUMENTS 04-08-2022

04/08/2022

ADDENDUM #1 05-27-2022

AutoCAD SHX Text 9E20

AutoCAD SHX Text 9E21

AutoCAD SHX Text 9E34

AutoCAD SHX Text A1

AutoCAD SHX Text A1

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text 9'-9 1/2"

AutoCAD SHX Text 9'-9 1/2"

AutoCAD SHX Text 12'-4 3/4"

AutoCAD SHX Text 12'-4 3/4"

AutoCAD SHX Text 9W13

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text

ROOM 9W07

AutoCAD SHX Text

ROOM 9E20

AutoCAD SHX Text

AutoCAD SHX Text 4'

AutoCAD SHX Text 2'

AutoCAD SHX Text 1'

AutoCAD SHX Text 6'

AutoCAD SHX Text 3/8"=1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

RM 9W100, 9W13 - DEMOLITION PLAN

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

AutoCAD SHX Text 4'

AutoCAD SHX Text 2'

AutoCAD SHX Text 1'

AutoCAD SHX Text 6'

AutoCAD SHX Text 3/8"=1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

RM 9E21, 9E20, 9E34 - DEMOLITION PLAN

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

XXXXX

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING PARTITION

AutoCAD SHX Text

EXISTING DOOR

AutoCAD SHX Text

AREA OF DEMOLITION WORK, SEE KEYNOTES

AutoCAD SHX Text

NEW PARTITION SURFACE MATERIAL

AutoCAD SHX Text

FLOOR PLAN LEGEND

AutoCAD SHX Text

ROOM NAME ROOM NUMBER

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text NOTE: NOT ALL NOTES APPLY TO EVERY DRAWING. NOT ALL NOTES APPLY TO EVERY DRAWING. A. SEE LIMITED ASBESTOS AND LEAD-CONTAINING PAINT SURVEY REPORT FOR SOW SEE LIMITED ASBESTOS AND LEAD-CONTAINING PAINT SURVEY REPORT FOR SOW IN EACH TR CLOSET. B. SEE ELECTRICAL DRAWINGS FOR TYPICAL TR CLOSET ELECTRICAL DEMOLITION. SEE ELECTRICAL DRAWINGS FOR TYPICAL TR CLOSET ELECTRICAL DEMOLITION. C. SEE DATA CENTER ELECTRICAL DRAWINGS FOR NEW SOW. SEE DATA CENTER ELECTRICAL DRAWINGS FOR NEW SOW. D. SEE FIRE PROTECTION DRAWINGS FOR TYPICAL SOW ON TR CLOSETS AND DATA SEE FIRE PROTECTION DRAWINGS FOR TYPICAL SOW ON TR CLOSETS AND DATA CENTER. E. PROVIDE TEMPORARY PROTECTION AT EXISTING AND NEW TR . CLOSET DOORS PROVIDE TEMPORARY PROTECTION AT EXISTING AND NEW TR . CLOSET DOORS DURING CONSTRUCTION. F. NO CEILING GRID AND ACOUSTICAL CEILING TILE AT TR CLOSETS. NO CEILING GRID AND ACOUSTICAL CEILING TILE AT TR CLOSETS. G. INSTALL STATIC DISSIPATIVE TILE (SDT) FLOORING AT TR CLOSETS - SEE ROOM INSTALL STATIC DISSIPATIVE TILE (SDT) FLOORING AT TR CLOSETS - SEE ROOM FINISH SCHEDULE SHEET 512. H. PATCH EXISTING WALLS TO MATCH NEW TR CLOSET FINISHED WALLS PATCH EXISTING WALLS TO MATCH NEW TR CLOSET FINISHED WALLS I. FOR IT INFORMATION AND SOW SEE DESIGN NARRATIVE/BASIS OF DESIGN FOR IT INFORMATION AND SOW SEE DESIGN NARRATIVE/BASIS OF DESIGN INCLUDED ON 75% SUBMITTAL. J. VERIFY IN FIELD ALL EXISTING CONDITIONS ILLUSTRATED ON THESE DRAWINGS. VERIFY IN FIELD ALL EXISTING CONDITIONS ILLUSTRATED ON THESE DRAWINGS. CONSTRUCTION DRAWINGS HAVE BEEN DEVELOPED REFERENCING AS-BUILT DRAWINGS PROVIDED BY THE VA. AND FIELD VERIFICATION CONDUCTED THROUGH VISUAL INVESTIGATION. NO SELECTIVE DEMOLITION OR EXPLORATORY INVESTIGATION WAS ABLE TO BE PERFORMED TO DISCOVER EXISTING CONDITIONS HAS BEEN EXECUTED DURING THE DISCOVER EXISTING CONDITIONS HAS BEEN EXECUTED DURING THE CREATION OF THESE DRAWINGS. THIS ALSO RESULTED IN LIMITED ACCESS TO HIDDEN WORK AREAS AND THEIR CONDITIONS DURING SITE INVESTIGATION ALL DIMENSIONS, EXISTING COMPONENTS OF NEW AND EXISTING COLUMN LOCATIONS MUST BE VERIFIED IN FIELD.

AutoCAD SHX Text

DEMOLITION PLAN LEGEND

AutoCAD SHX Text EXISTING CONSTRUCTION TO BE REMOVED IN ITS ENTIRETY, INCLUDING WALL SWITCHES, OUTLETS, THERMOSTATS, ETC. PATCH ABUTTING WALLS, FLOORS AND CEILINGS AS REQUIRED. REMOVE EXISTING ITEMS SCHEDULED TO REMAIN AS NECESSARY TO ALLOW THE COMPLETE DEMOLITION OF SELECTED ITEMS. REPAIR/REPLACE EXISTING ITEMS ONCE DEMOLITION IS COMPLETED.

AutoCAD SHX Text

EXISTING CONSTRUCTION TO REMAIN

AutoCAD SHX Text

FLOOR PLAN KEY NOTES

AutoCAD SHX Text X

AutoCAD SHX Text NOTE: NOT ALL NOTES APPLY TO EVERY DRAWING. NOT ALL NOTES APPLY TO EVERY DRAWING. 1. 42"x84" SOLID CORE WOOD DOOR WITH HOLLOW METAL FRAME. SEE DR SCHEDULE. 42"x84" SOLID CORE WOOD DOOR WITH HOLLOW METAL FRAME. SEE DR SCHEDULE. 2. FINISH WALL CORNER TO CORNER AND FLOOR TO CEILING. PRIOR TO PAINTING THE FINISH WALL CORNER TO CORNER AND FLOOR TO CEILING. PRIOR TO PAINTING THE ENTIRE WALL SURFACE WITH (1) FINISH COAT OF PAINT, PROVIDE (1) PRIME COAT AND (2) FINISH COATS OVER PATCHED/REPAIRED WALL SURFACES. 3. EXISTING WINDOW GLAZING WILL REQUIRE RETROFIT (8 MIL ANTI SHATTER FILM) TO EXISTING WINDOW GLAZING WILL REQUIRE RETROFIT (8 MIL ANTI SHATTER FILM) TO MEET VA PSRDM REQUIREMENTS - 1/2" SILICONE SEALANT AT ALL (4) SIDES. 4. REPLACE EXISTING WINDOW GLAZING WITH 1.125 LAMINATED IGU - 3/8" SILICONE REPLACE EXISTING WINDOW GLAZING WITH 1.125 LAMINATED IGU - 3/8" SILICONE AT ALL (4) EDGES. 5. FUTURE USE OF UTILITY CLOSET TO BE DETERMINED BY VA OR CURRENTLY UNDER CONSTRUCTION. SEE MEP & IT DRAWINGS FOR ADDITIONAL SOW IN THIS AREA. 6. EXISTING RAISED COMPUTER FLOORING TO REMAIN.

AutoCAD SHX Text

EXISTING DOOR TO BE REMOVED

AutoCAD SHX Text

DEMOLITION KEY NOTES

AutoCAD SHX Text NOTE: NOT ALL NOTES APPLY TO EVERY DRAWING. NOT ALL NOTES APPLY TO EVERY DRAWING. 1. REMOVE EXISTING DOOR, FRAME AND ALL ASSOCIATED HARDWARE REMOVE EXISTING DOOR, FRAME AND ALL ASSOCIATED HARDWARE 2. REMOVE EXISTING PARTITION IN ITS ENTIRETY INCLUDING ALL FRAMING, BRACING REMOVE EXISTING PARTITION IN ITS ENTIRETY INCLUDING ALL FRAMING, BRACING AND SUPPORTS. 3. REMOVE EXISTING CEILING, GRID, AND ACOUSTICAL TILE, INCLUDING ALL RELATED REMOVE EXISTING CEILING, GRID, AND ACOUSTICAL TILE, INCLUDING ALL RELATED MOLDINGS , TRIM, WIRESUPPORTS, AND/OR BRACING THROUGHOUT THE AREA. 4. REMOVE EXISTING LIGHT FIXTURE. REFER TO ELECTRICAL DRAWINGS REMOVE EXISTING LIGHT FIXTURE. REFER TO ELECTRICAL DRAWINGS 5. REMOVE EXISTING DIFFUSER. REFER TO MECHANICAL DRAWINGS REMOVE EXISTING DIFFUSER. REFER TO MECHANICAL DRAWINGS 6. REMOVE EXISTING GYPSUM BOARD CEILING. REMOVE EXISTING GYPSUM BOARD CEILING. 7. REMOVE EXISTING GYPSUM BOARD SOFFIT AND BULKHEAD. REMOVE EXISTING GYPSUM BOARD SOFFIT AND BULKHEAD. 8. REMOVE IN THEIR ENTIRETY ALL EXISTING WALL-MOUNTED ITEMS. COORDINATE ITEM REMOVE IN THEIR ENTIRETY ALL EXISTING WALL-MOUNTED ITEMS. COORDINATE ITEM DISPLACEMENT WITH THE VA. 9. REMOVE EXISTING WINDOW IN ITS ENTIRETY INCLUDING GLAZING, FRAME AND SILL. REMOVE EXISTING WINDOW IN ITS ENTIRETY INCLUDING GLAZING, FRAME AND SILL. 10. REMOVE EXISTING FLOORING (I.E. CARPET, LAMINATE FLOORING, VCT) TO EXISTING REMOVE EXISTING FLOORING (I.E. CARPET, LAMINATE FLOORING, VCT) TO EXISTING CONCRETE. SCRAPE CLEAN AND REMOVE ALL ASSOCIATED ADHESIVE. PREP AND LEVEL EXISTING CONCRETE FLOOR TO RECEIVE NEW FINISH. 11. REMOVE VINYL BASE ALONG EXISTING WALL. REMOVE VINYL BASE ALONG EXISTING WALL. 12. G.C. TO CAREFULLY REMOVE SYSTEMS FURNITURE AND ALL WALL MOUNTED G.C. TO CAREFULLY REMOVE SYSTEMS FURNITURE AND ALL WALL MOUNTED EQUIPMENT AND TURN OVER TO V.A. 13. G.C. TO CAREFULLY REMOVE EXISTING WINDOW TREATMENT AND TURN OVER TO G.C. TO CAREFULLY REMOVE EXISTING WINDOW TREATMENT AND TURN OVER TO VA. 14. SUPPLY AND INSTALL WALK OFF MAT(S). SEE DETAILS ON SHEET #####. SUPPLY AND INSTALL WALK OFF MAT(S). SEE DETAILS ON SHEET #####. #####. . 15. SUPPLY AND INSTALL 6 MIL HEAVY DUTY, REINFORCED, FIRE-RETARDANT, POLY SUPPLY AND INSTALL 6 MIL HEAVY DUTY, REINFORCED, FIRE-RETARDANT, POLY SHEETING. PLASTIC SHEET SHALL BE FULLY SEALED AT PERIMETER. PROVIDE ZIPPER OPENING FOR ACCESS. 16. SUPPLY AND INSTALL 6 MIL HEAVY DUTY, REINFORCED, FIRE-RETARDANT, POLY SUPPLY AND INSTALL 6 MIL HEAVY DUTY, REINFORCED, FIRE-RETARDANT, POLY SHEETING. PLASTIC SHEET SHALL BE FULLY SEALED AT PERIMETER AND SHALL EXTEND TO UNDERSIDE OF STRUCTURE. 17. FOR REFERENCE ONLY. NO ARCHITECTURAL WORK ON THESE ROOMS. SEE OTHER FOR REFERENCE ONLY. NO ARCHITECTURAL WORK ON THESE ROOMS. SEE OTHER DISCIPLINES FOR ADDITIONAL SCOPE OF WORK.

AutoCAD SHX Text X

AutoCAD SHX Text

DEMO CEILING KEYNOTES

AutoCAD SHX Text

17. REMOVE EXISTING ACT CEILING ASSEMBLE TO NEXT FULL TILE, INCLUDING REMOVE EXISTING ACT CEILING ASSEMBLE TO NEXT FULL TILE, INCLUDING GRID, TILE , RELATED MOLDINGS, TRIM, WIRESUPPORTS AND/OR BRACING. G.C. SHALL TEMPORARY SUPPORT REMAINING EXISTING ACT CEILING SYSTEM UNTIL NEW WALL IS CONSTRUCTED. NEW ACT CEILING SYSTEM AND TILES SHALL BE INSTALLED TO MATCH EXISTING.

AutoCAD SHX Text NEW FULLY RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED. PATCH AND MATCH EXISTING CONDITIONS

AutoCAD SHX Text

BUILDING 1 - NINTH FLOOR KEY PLAN

AutoCAD SHX Text N

AutoCAD SHX Text

AutoCAD SHX Text 4'

AutoCAD SHX Text 2'

AutoCAD SHX Text 1'

AutoCAD SHX Text 6'

AutoCAD SHX Text 3/8"=1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

RM 9W100, 9W13 - NEW WORK PLAN

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

AutoCAD SHX Text 4'

AutoCAD SHX Text 2'

AutoCAD SHX Text 1'

AutoCAD SHX Text 6'

AutoCAD SHX Text 3/8"=1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

RM 9E21, 9E20, 9E34 - NEW WORK PLAN

AutoCAD SHX Text

NORTH

Sheets and Views
01 A409

File details come from the government source that posted it. Updated .