Attachment 25 - 578-21-703 ASK-01 Metal Panel Detail.pdf

PDF 321 KB Posted

Attached to
Z1DZ--EHRM Training and Admin Space - Construction Phase 1 - Hines, IL (VA-21-00027896)
Solicitation number
36C77621B0006
Issued by

About this file

This document provides details for a federal contract opportunity to renovate the building enclosure and perform interior demolition for a training and administration space at a Department of Veterans Affairs medical center. The solicitation will be issued as an Invitation for Bid to renovate the building enclosure of Building 20 and perform selective demolition of the interior at the Hines VA Medical Center in Hines, Illinois. The work includes all labor, management, and materials for renovations to the building enclosure and interior demolition. The solicitation will be set aside for Service-Disabled Veteran-Owned Small Businesses and issued on or around February 22, 2021. The period of performance is approximately 120 calendar days from the issuance of the notice to proceed. The estimated value of the construction is between $1 million and $2 million.

View the file

Other files

File Type Posted
578-21-703 sign in pre bid.pdf PDF
36C77621B0006 0004.docx DOCX document
36C77621B0006 0003.docx DOCX document
21) Revised 578-21-703 Specification Book r20210317.pdf PDF
36C77621B0006 0002.docx DOCX document
Attachment 26 - Hines Underground Utility Plan.pdf PDF
S05 - Technical Question and Answers Hines IFB 36C77621B0006.docx DOCX document
36C77621B0006 0001.docx DOCX document
Attachment 24 - SOW 578-21-703 EHRM Training and Admin Space Support - Phase 1 - Hines IL 2020-12-30.docx DOCX document
Attachment 27 - Inspection Summary Report Bldg 20 - 2010.pdf PDF
Attachment 28 - BLDG 20 R2010.xls XLS spreadsheet
Attachment 20 Revised - 578-21-703 Combined Drawing Set.pdf PDF
S02 - Solicitation 36C77621B0006 Final Released.docx DOCX document
23) Wage Determination DBA - Cook County.pdf PDF
2) Hines Underground Utility Plan.pdf PDF
1) Hines VA Campus Site Plan.pdf PDF
15) Infection Control Barrier Sample.pdf PDF
19) 578-21-703 Photos of Current Conditions.pdf PDF
3) Pre-Construction Checklist.pdf PDF
21) 578-21-703 Specification Book.pdf PDF
12) Contractor Parking.pdf PDF
9) Interim Life Safety Measures (ILSM).pdf PDF
18) Hines COVID-19 Guidelines.pdf PDF
7) Above Ceiling Entry and Wall Construction Permits.pdf PDF
5) Cutting Welding and Other Hot Work.pdf PDF
36C77621B0006.docx DOCX document
14) No Smoking Policy 10-1-19.pdf PDF
6) Dig Permit SOP Form.pdf PDF
11) Contractor PIV Instructions and Form.pdf PDF
20) 578-21-703 Combined Drawing Set.pdf PDF
16) Building 20 Renovation from 1989.pdf PDF
13) OIT Horizontal Cable Requirements.pdf PDF
8) Pre-Construction Risk Assessment (PCRA).pdf PDF
17) Building 20 Asbestos Survey 2011.pdf PDF
4) Safety and Health During Construction Activities.pdf PDF
22) CONTRACTOR SAFETY AND ENVIRONMENTAL RECORD EVALUATION FORM.docx DOCX document
10) Infection Control Risk Assessment (ICRA).pdf PDF
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

The design, fabrication and installation of the ALPOLIC® panels are the sole responsibility of the purchaser. The information contained on this website is for conceptual use only.

Mitsubishi Chemical Composites America, Inc. shall have no responsibility or liability for the products usage or infringement of any patent or other proprietary right.

WET SEAL SYSTEM

10.01.05 www.alpolic-americas.com

SILL DETAIL

SILL FLASHING W/ VERTICAL

LEG BEHIND METAL PANEL,

END DAMS AND HEMMED

EXPOSED EDGE

EXISTING

BRICK WALL

CONT SEALANT

AND BACKER

ROD

2" DEEP FORMED METAL

PANEL MADE FROM 4MM

ALUMINUM COMPOSITE

MATERIAL

COLOR TO BE CHOSEN

FROM MANUFACTURERS

STANDARD COLORS

6" INSULATION

PERIMETER ALUMINUM

CLIP ANGLES ANCHORED

INTO BRICK

578-21-703 EHRM BUILDING 20

ASK-01

3/12/2021

4MM ALUMINUM COMPOSITE MATERIAL SHALL BE

ALPOLIC/FR, ALUCOBOND PLUS, OR AN EQUAL

ACCEPTABLE TO THE COR

3/4"

The design, fabrication and installation of the ALPOLIC® panels are the sole responsibility of the purchaser. The information contained on this website is for conceptual use only.

Mitsubishi Chemical Composites America, Inc. shall have no responsibility or liability for the products usage or infringement of any patent or other proprietary right.

WET SEAL SYSTEM

10.01.05 www.alpolic-americas.com

2" DEEP FORMED METAL

PANEL MADE FROM 4MM

ALUMINUM COMPOSITE

MATERIAL

COLOR TO BE CHOSEN

FROM MANUFACTURERS

STANDARD COLORS

6" INSULATION

CONT SEALANT

AND BACKER

ROD

EXISTING

BRICK WALL

JAMB AND HEAD DETAIL

PERIMETER ALUMINUM

CLIP ANGLES ANCHORED

INTO BRICK

578-21-703 EHRM BUILDING 20

ASK-01

3/12/2021

3/4"