36C25018B0816-005.pdf
PDF 7 MB Posted
- Attached to
- Reno 4th Fl Bldg 138 610-17-101 Federal contract opportunity
- Solicitation number
- 36C25018B0816
About this file
36C25018B0816 ATTACHMENT 4. Structural Drawings.pdf
View the file
Other files for this federal contract opportunity
Show all 37
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT
AREA
Kuder Place
Indiana Avenue
Indiana Avenue
H y d e R o a d
Irw in
D riv e
Chapman Avenue
Chapman
H y d e R o a d
M a rio n R o a d
B lack R o a d
O rc h a rd
A v e n u e
Indiana Avenue
F lo w e r
S tre e t
F lo w e r
S tr e e t
Chapman Avenue
Ave.
N e l s o n A v e n u e
O rc h a rd
A v e n u e
Chapman Avenue
River Road
National
Cemetery
National
Cemetery
National
Cemetery
D
IX
R O A D
38 Street
L in c o ln
B o u le v a rd
McMahon
G ra y R o a d Steel Circle
Avenue
C o tt a g e
A v e n u e
B la c k
R o a d
B la ck R o a d
C o tt a g e
A v e n u e
G ra y R o a d
Water Street
Black Road
Black Road
Water Street
Nelson
Avenue
Orchard
Avenue
M c M a h o n
A v e n u e
Doctors Road
V in e
Drive
Vine
Water Street
Railroad Avenue
M e c h a n ic s A v e n u e R
I
V
E o a d
Road
B la ck
R o a d
B la c k
R o a d
Material
Compoun d
Vehicle
Compound
Cemetery
Dump
Main Entrance
N
P A R K
D R
IV
E
CONTRACTOR
ENTRANCE/EXIT LOCATION
DEBRIS CHUTE AND
DUMPSTER LOCATION
DEBRIS CHUTE AND
DUMPSTER
ALTERNATE LOCATION
CONTRACTOR
PARKING &
LAYDOWN AREA
PROJECT LOCATION
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
C
Phase
ARCHITECT OF RECORD STAMPENGINEERS OF RECORD
321 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
A/E:
C on e ei gh th in ch o ne fo ot
B
A
C
D
E
F th re e in ch es o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot on e ha lf in ch o ne fo ot
6"
6"
6"
6"
C :\r vt \2
6\
8 3
-A
-C E
N T
R A
L_ V
I S N
-1
-4 th F lo or
_ M
IN
E
LS
O N
.r vt
C :\r vt \2
6\
8 3
-A
-C E
N T
R A
L_ V
I S N
-1
-4 th F lo or
_ M
IN
E
LS
O N
.r vt
/1
/2
:1 :4
P
M
G-000
COVER SHEET 610-17-101
11/29/17 ED MN
ISSUED FOR
CONSTRUCTION
Project Director
1700 E. 38TH STREET MARION, IN 46953
VISN 11 MARION B-138: 4TH FLOOR
CONSTRUCTION
SPRINKLERED
HDR ARCHITECTURE, INC.
600 HENNEPIN AVE SUITE 260
MINNEAPOLIS, MN 55403
612.524.6000
TERRY LITTELL SR., RA,
LEED AP
KORDA, INC.
1650 WATERMARK DRIVE, SUITE 200
COLUMBUS, OH 43215
614.487.1650
STAN KMONK
METRIC ENVIRONMENTAL
6971 HILLSDALE COURT
INDIANAPOLIS, IN 46250
VA NORTHERN INDIANA HEALTH CARE SYSTEM
RENOVATE 4TH FLOOR, BUILDING 138
MARION, INDIANA
CONTRACT DOCUMENTS
ISSUED FOR CONSTRUCTION
MARCH 19, 2018
PROJECT NUMBER: 610-17-101
PROJECT LOCATION
1700 EAST 38TH STREET, MARION INDIANA, 46953
LOCATION MAP
PLUMBING
PD103.1 THIRD FLOOR PLUMBING DEMOLITION PLAN PHASE 1
PD103.2 THIRD FLOOR PLUMBING DEMOLITION PLAN PHASE 2
PD104.1 FOURTH FLOOR PLUMBING DEMOLITION PLAN PHASE 1
PD104.2 FOURTH FLOOR PLUMBING DEMOLITION PLAN PHASE 2
PD105.1 ROOF PLUMBING DEMOLITION PLAN PHASE 1
PD105.2 ROOF PLUMBING DEMOLITION PLAN PHASE 2
PG114.1 FOURTH FLOOR MEDICAL GAS PIPING DEMOLITION PLAN PHASE 1
PG114.2 FOURTH FLOOR MEDICAL GAS PIPING DEMOLITION PLAN PHASE 2
PG304.1 FOURTH FLOOR MEDICAL GAS PIPING NEW WORK PLAN PHASE 1
PG304.2 FOURTH FLOOR MEDICAL GAS PIPING NEW WORK PLAN PHASE 2
PJ601 PLUMBING DETAILS
PP203.1 THIRD FLOOR PLUMBING NEW WORK PLAN PHASE 1
PP203.2 THIRD FLOOR PLUMBING NEW WORK PLAN PHASE 2
PP204.1 FOURTH FLOOR PLUMBING NEW WORK PLAN PHASE 1
PP204.2 FOURTH FLOOR PLUMBING NEW WORK PLAN PHASE 2
PP205.1 ROOF & PENTHOUSE ROOF PLUMBING NEW WORK PLAN PHASE 1
PP205.2 ROOF & PENTHOUSE ROOF PLUMBING NEW WORK PLAN PHASE 2
PP401 ROOF PLUMBING NEW WORK PLAN PHASE 1 & 2- ALTERNATE
PQ501 PLUMBING SCHEDULES & SYMBOLS LIST
PW701 PLUMBING RISERS
PW702 PLUMBING STACKS
PW703 PLUMBING STACKS
HVAC
MD104.1 FOURTH FLOOR HVAC DEMOLITION PLAN PHASE 1
MD104.2 FOURTH FLOOR HVAC DEMOLITION PLAN PHASE 2
MD105.1 ROOF HVAC DEMOLITION PLAN PHASE 1
MD105.2 ROOF HVAC DEMOLITION PLAN PHASE 2
MH204.1 FOURTH FLOOR HVAC NEW WORK PLAN PHASE 1
MH204.2 FOURTH FLOOR HVAC NEW WORK PLAN PHASE 2
MH205.1 ROOF HVAC NEW WORK PLAN PHASE 1
MH205.2 ROOF HVAC NEW WORK PLAN PHASE 2
MH401 HVAC ENLARGED PLANS
MH402 HVAC ENLARGED PLANS
MH403 SECTIONS
MH404 HVAC ENLARGED PLANS - ALTERNATE ROOFTOP UNITS
MH501 HVAC SCHEDULES & SYMBOLS LIST
MH502 HVAC SCHEDULES
MH601 HVAC DETAILS
MH602 HVAC DETAILS
MH603 HVAC DETAILS
MH604 HVAC DETAILS
MH605 HVAC DETAILS
MH701 HVAC ZONES
MP304.1 FOURTH FLOOR HVAC PIPING NEW WORK PLAN PHASE 1
MP304.2 FOURTH FLOOR HVAC PIPING NEW WORK PLAN PHASE 2
ELECTRICAL
E-000 ELECTRICAL SYMBOL LIST
ED104.1 ELECTRICAL FOURTH FLOOR DEMOLITION PLAN - PHASE 1
ED104.2 ELECTRICAL FOURTH FLOOR DEMOLITION PLAN - PHASE 2
EL204.1 ELECTRICAL FOURTH FLOOR LIGHTING PLAN - PHASE 1
EL204.2 ELECTRICAL FOURTH FLOOR LIGHTING PLAN - PHASE 2
EP301 ELECTRICAL BASEMENT EXISTING POWER PLAN
EP304.1 ELECTRICAL FOURTH FLOOR POWER PLAN - PHASE 1
EP304.2 ELECTRICAL FOURTH FLOOR POWER PLAN - PHASE 2
EP304.3 ELECTRICAL OVERALL ROOF PLAN
EP304.4 ELECTRICAL PENTHOUSE PLANS
EP304.4A ELECTRICAL PENTHOUSE PLANS - ALTERNATE
EP304.5 ELECTRICAL CONDUIT ROUTING PLAN
EP401 ELECTRICAL ENLARGED PLANS
EJ501 ELECTRICAL SCHEDULES
EJ502 ELECTRICAL SCHEDULES
EJ601 PARTIAL ELECTRICAL ONE-LINE DIAGRAM
EJ602 ELECTRICAL ONE-LINE DIAGRAM SCHEDULES
EJ603 ELECTRICAL RISER DIAGRAM - DEMOLITION
EJ604 ELECTRICAL RISER DIAGRAM - NEW WORK
EK701 ELECTRICAL DETAILS
FA804.1 ELECTRICAL FOURTH FLOOR FIRE ALARM PLAN - PHASE 1
FA804.2 ELECTRICAL FOURTH FLOOR FIRE ALARM PLAN - PHASE 2
FA804.3 ELECTRICAL PENTHOUSE FIRE ALARM PLANS - PHASE 2
FA804.4 ELECTRICAL FIRE ALARM DETAILS
TECHNOLOGY
ET000 TECHNOLOGY SYMBOL LIST
ET204.1 TECHNOLOGY FOURTH FLOOR PLAN - PHASE 1
ET204.2 TECHNOLOGY FOURTH FLOOR PLAN - PHASE 2
ET304.1 TECHNOLOGY FOURTH FLOOR PLAN - RTLS - PHASE 1
ET304.2 TECHNOLOGY FOURTH FLOOR PLAN - RTLS - PHASE 2
ET401 TECHNOLOGY ENLARGED PLANS
ET402 TECHNOLOGY ENLARGED PLANS
ET701 TECHNOLOGY DETAILS
ET702 TECHNOLOGY DETAILS
GENERAL
G-000 COVER SHEET
G-101 ABBREVIATIONS, SYMBOLS, & GENERAL NOTES
GI-104 LIFE SAFETY
GI-204 FOURTH FLOOR - INFECTION CONTROL PLAN
GC-101 PHASING PLAN
HAZARDOUS
HA-101 THIRD FLOOR ABATEMENT PLAN
HA-102 FOURTH FLOOR ABATEMENT PLAN
STRUCTURAL
SS001 STUCTURAL NOTES
SS101 FRAMING PLANS - UNIT B
SS102 FRAMING PLANS - UNIT C
SS103 4TH FL RENOVATION - PHASE 1
SS104 4TH FL RENOVATION - PHASE 2
SS105 ALTERNATE FRAMING PLANS - UNITS B & C
SS301 STRUCTURAL SECTIONS
ARCHITECTURAL
AD-103 THIRD FLOOR DEMOLITION PLAN
AD-104 FOURTH FLOOR DEMOLITION PLAN - OVERALL
AD-104.1 FOURTH FLOOR DEMOLITION PLAN - PHASE 1
AD-104.2 FOURTH FLOOR DEMOLITION PLAN - PHASE 2
AD-105 ROOF DEMOLITION PLAN
A-002 TYPICAL MOUNTING HEIGHTS
A-003 ALTERNATE #2 DEFINITION
A-103 THIRD FLOOR PLAN - OVERALL
A-104 FOURTH FLOOR PLAN - OVERALL
A-104.1 FOURTH FLOOR PLAN - PHASE 1
A-104.2 FOURTH FLOOR PLAN - PHASE 2
A-105 PENTHOUSE FLOOR & ROOF PLANS
AR-105 ROOF PLAN
AC-104.1 FOURTH FLOOR REFLECTED CEILING PLAN - PHASE 1
AC-104.2 FOURTH FLOOR REFLECTED CEILING PLAN - PHASE 2
AC-501 CEILING DETAILS
A-201 EXTERIOR ELEVATIONS & SECTIONS
A-202 DUCT CHASE SECTIONS
A-461 CASEWORK SECTIONS
A-501 EXTERIOR DETAILS
A-550 DETAILS
A-601 DOOR AND FRAME SCHEDULES
A-602 DOOR AND FRAME TYPES AND DETAILS
A-701 WALL TYPES
A-702 INTERIOR FRAMING DETAILS
A-800 INTERIOR 3D PERSPECTIVES
AW-101 SIGNAGE PLACEMENT PLAN - PHASE 1
AW-102 SIGNAGE PLACEMENT PLAN - PHASE 2
AW-103 SIGNAGE MESSAGE SCHEDULE PHASE 1
AW-104 INTERIOR SIGNAGE STANDARDS
AW-105 INTERIOR SIGNAGE- LIFE SAFETY SIGN TYPES
AW-106 INTERIOR SIGNAGE- LIFE SAFETY SIGN TYPES
AW-107 INTERIOR SIGNAGE- ROOM ID SIGNS
AW-108 INTERIOR SIGNAGE- WAYFINDING
INTERIORS
I-104.1 FOURTH FLOOR - INTERIOR WALL FINISH PLAN - PHASE 1
I-104.2 FOURTH FLOOR - INTERIOR WALL FINISH PLAN - PHASE 2
IN-104.1 FOURTH FLOOR - FLOOR PATTERN PLAN - PHASE 1
IN-104.2 FOURTH FLOOR - FLOOR PATTERN PLAN - PHASE 2
IP-104.1 FOURTH FLOOR - WALL PROTECTION PLAN - PHASE 1
IP-104.2 FOURTH FLOOR - WALL PROTECTION PLAN - PHASE 2
I-201 INTERIOR ELEVATIONS - PHASE 1
I-202 INTERIOR ELEVATIONS - PHASE 1
I-203 INTERIOR ELEVATIONS - PHASE 1
I-210 INTERIOR ELEVATIONS - PHASE 2
I-211 INTERIOR ELEVATIONS - PHASE 2
I-501 INTERIOR FINISH DETAILS
EQUIPMENT
Q-100 EQUIPMENT SCHEDULE
Q-101 EQUIPMENT SCHEDULE
Q-104.1 FOURTH FLOOR FURNITURE & EQUIPMENT - PHASE 1
Q-104.2 FOURTH FLOOR FURNITURE & EQUIPMENT - PHASE 2
Q-601 PHASE 1 EQUIPMENT SCHEDULE
Q-602 PHASE 2 EQUIPMENT SCHEDULE
FIRE PROTECTION
FX104.1 FOURTH FLOOR FIRE PROTECTION DEMOLITION PLAN PHASE 1
FX104.2 FOURTH FLOOR FIRE PROTECTION DEMOLITION PLAN PHASE 2
FX105.1 ROOF FIRE PROTECTION DEMOLITION PLAN PHASE 1
FX204.1 FOURTH FLOOR & PENTHOUSE FIRE PROTECTION NEW WORK PLAN
PHASE 1
FX204.2 FOURTH FLOOR & PENTHOUSE FIRE PROTECTION NEW WORK PLAN
PHASE 2
FX501 FIRE PROTECTION DETAILS & SYMBOLS LIST
Mark: Revision: Date:
ISSUED FOR CONSTRUCTION 03/19/2018
03-19-18 03/19/18
ABBREVIATIONS
° DEGREE
± PLUS/MINUS
Ø DIAMETER
≈ ALMOST EQUAL
∠ ANGLE
� BOUNDARY LINE
℄ CENTER LINE
∆ DELTA, DEFLECTION ANGLE
Φ ELECTRICAL PHASE
� FLOW LINE
≡ IDENTITY
� INITIAL LENGTH
� MOMENT LINE
≠ NOT EQUAL
Ω OHM
Ω OMEGA
� PROPERTY LINE
ABCDEFGHIJKMNOPQRSTUVWXYZ 1234567890
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AAMA AMERICAN ARCHITECTURAL
MANUFACTURERS ASSOCIATION
AB ANCHOR BOLT, AUGER BORING
ABA ARCHITECTURAL BARRIERS ACT
ABC AGGREGATE BASE COURSE
ABS AIR BREAK SWITCH
AC ASBESTOS CEMENT OR ASPHALTIC
CONCRETE
ACB AIR CIRCUIT BREAKER
ACI AMERICAN CONCRETE INSTITUTE
ACS DR ACCESS DOOR
ACS FLR ACCESS FLOOR
ACS PNL ACCESS PANEL
ACSR ALUMINUM CONDUCTOR STEEL
REINFORCED
ACST ACOUSTIC
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADC AUTOMATIC DOOR CLOSER
ADDL ADDITIONAL
ADDN ADDITION
ADH ADHESIVE
ADJ ADJACENT, ADJOINING, OR ADJUSTABLE
ADMIN ADMINISTRATION
ADB AUTOMATIC DOOR BOTTOM
ADO AUTOMATIC DOOR OPERATOR
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGA AMERICAN GAS ASSOCIATION
AGC ASSOCIATED GENERAL CONTRACTORS
AGGR AGGREGATE
AHJ AUTHORITY HAVING JURISDICTION
AHR ANCHOR
AHU AIR HANDLING UNIT
AIA AMERICAN INSTITUTE OF ARCHITECTS
AISC AMERICAN INSTITUTE OF STEEL
CONSTRUCTION
AL ALUMINUM
ALT ALTERNATE
ALT NO ALTERNATE NUMBER
ALUM ALUMINUM
AM ACOUSTIC MATERIAL
AMP AMPERE
AMT AMOUNT
ANOD ANODIZE
ANSI AMERICAN NATIONAL STANDARDS
INSTITUTE
ANT ANTENNA
AP ACCESS PANEL, APPROX.,
APPROXIMATE
APA AMERICAN PLYWOOD ASSOCIATION
APPD APPROVED
APPROX APPROXIMATE
APT APARTMENT
AR AS REQUIRED
ARR ARRESTOR
ARCH ARCHITECT, ARCHITECTURAL
ASB ASBESTOS
ASI ARCHITECT'S SUPPLEMENTAL
INSTRUCTION
ASKLR AUTOMATIC SPRINKLER
ASPH ASPHALT
ASSN ASSOCIATION
ASTM AMERICAN SOCIETY FOR TESTING AND
MATERIALS
ATCH ATTACHMENT
ATM AUTOMATIC TELLER MACHINE
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AVE AVENUE
AVG AVERAGE
AW ACID WASTE
AWI ARCHITECTURAL WOODWORKING
INSTITUTE
AWPA AMERICAN WOOD PRESERVERS'
ASSOCIATION
AWS AMERICAN WELDING SOCIETY
AWT ACOUSTICAL WALL TREATMENT
B BASELINE, BOTTOM
B LABEL CLASS B DOOR
B PL BASE PLATE
BALC BALCONY
BAT BATTEN
BB BULLETIN BOARD
BD BOARD
BD FT BOARD FEET (FOOT)
BEJ BRICK EXPANSION JOINT
BEV BEVEL
BHMA BUILDER'S HARDWARE
MANUFACTURER'S ASSOCIATION
BI FLD DR BIFOLDING DOORS
BITUM BITUMINOUS
BKG BACKING
BLD BUILD
BLDG BUILDING
BLKT BLANKET
BLVD BOULEVARD
BM BEAM OR BENCHMARK
BO BOARD
BOT BOTTOM
BR BEDROOM, BOTTOM REGISTER
BRCG BRACING
BRDG BRIDGING
BRDG JST BRIDGING JOIST
BRG BEARING
BRG PL BEARING PLATE
BRKT BRACKET
BRZ BRONZE
BSMT BASEMENT
BTWN BETWEEN
BU BUSHEL
BUR BUILT-UP ROOFING
C CELSIUS, CHANNEL
C CONC CAST CONCRETE
C LABEL CLASS C DOOR
C TO C CENTER TO CENTER
CAB CABINET
CAC CEILING ATTENUATION CLASS
CB CATCH BASIN, CORNER BEAD, CIRCUIT
BREAKER
CBB CEMENTITIOUS (BACKER) BOARD
CC CUBIC CENTIMETER, CONTRACTOR
SUPPLIED & INSTALLED
CCTV CLOSED CIRCUIT TELEVISION
CCW COUNTERCLOCKWISE
CD CONSTRUCTION DOCUMENTS,
CONTRACT DOCUMENTS, CEILING
DIFFUSER
CEM CEMENT
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/CONTRACTOR
INSTALLED
CF/OI CONTRACTOR FURNISHED/OWNER
INSTALLED
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CENTER OF GRAVITY, CORNER GUARD
C&G CURB AND GUTTER
CGSFU CERAMIC GLAZED STRUCTURAL FACING
UNITS
CH CHILLER
CH BD CHALKBOARD
CHEM CHEMICAL
CHFR CHAMFER
CHK CHECK
CI CAST IRON
CIP CAST-IN-PLACE
CIR CIRCLE
CIRC CIRCULAR
CJ CONSTRUCTION JOINT OR CONTROL JOINT
CL CENTER LINE
CLDG CLADDING
CLG CEILING
CLG HT CEILING HEIGHT
CLR CLEAR
CM² SQUARE CENTIMETER
CM³ CUBIC CENTIMETER
CM CONSTRUCTION MANAGEMENT
CMP CORRUGATED METAL PIPE
CMPA CORRUGATED METAL PIPE ARCH
CMU CONCRETE MASONRY UNIT
CND CONDUIT
CNDS CONDENSATE
CNR CORNER
CNTR COUNTER
CO CARBON MONOXIDE, CERTIFICATE OF
OCCUPANCY, CLEANOUT, OR COMPANY
CO∠ CARBON DIOXIDE
CODP CLEANOUT W/ DECK PLUG
COL COLUMN
COM COMMON
COMB COMBINATION, COMBINED
COMM COMMUNICATION
COMP COMPONENT
CONC CONCRETE
CONC FLR CONCRETE FLOOR
COND CONDENSER OR CONDITION
CONF CONFERENCE
CONN CONNECT, CONNECTION
CONSTR CONSTRUCTION
CONT CONTINUE
CONTR CONTRACTOR, CONTRACTION
COORD COORDINATE
CORR CORRIDOR
CP NON-REINFORCED CONCRETE PIPE
CPM CRITICAL PATH METHOD
CPRS COMPRESSIBLE
CPT CARPET
CR CHAIR, CRASH RAIL
CRS COLD ROLLED STEEL
CRSI CONCRETE REINFORCING STEEL
INSTITUTE
CS CONCRETE SEALER/SURFACE
CSB CONCRETE SPLASH BLOCK
CSG CASING
CSI CONSTRUCTION SPECIFICATIONS
INSTITUTE
CSK COUNTER SUNK
CSMT CASEMENT
CSWK CASEWORK
CT CERAMIC TILE, CURRENT
TRANSFORMER,
COOLING TOWER
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTG COATING
CTR CENTER, CONTOUR, COOLING TOWER
RETURN
CTRL CONTROL
CTV CABLE TELEVISION
CU COPPER C
CUH CABINET UNIT HEATER
CU FT CUBIC FEET
CU IN CUBIC INCH
CU YD CUBIC YARD
CUH CABINET UNIT HEATER
CURT CURTAIN
CW COLD WATER
CWB CAPILLARY WATER BARRIER
CYL CYLINDER
CYL L CYLINDER LOCK
D DEPTH OR PENNY (NAIL)
D LABEL CLASS D DOOR
DAT DATUM
DB DECIBEL, DRY BUILT, DIRECT BURIAL
DBL DOUBLE
DBL GLZ DOUBLE GLAZE
DC DIRECT CURRENT
DD DIVERSION DIKE
DEG, ° DEGREE
DEL DELETE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DI DUCTILE IRON
DIA, DIAMETER
DIAG DIAGONAL DIAGRAM
DIAG DIAGRAM DIAGONAL
DIFF DIFFERENCE OR DIFFUSER
DIM DIMENSION
DIR DIRECTION
DISP DISPENSER
DIST DISTANCE
DIV DIVIDE OR DIVISION
DL DEAD LOAD
DMPR DAMPER
DN DOWN
DP DISTRIBUTION
DOC DOCUMENT
DOUG FIR DOUGLAS FIR
DOZ DOZEN
DR DOOR, DRAIN, DRESSING ROOM, OR
DRIVE
DR CL DOOR CLOSER
DR FR DOOR FRAME
DR OPNG DOOR OPENING
DS DOWNSPOUT, STORM DRAINAGE
STRUCTURE
DSGN DESIGN
DW DISHWASHER, DOMESTIC WATER
DWD DRINKING WATER DISPENSER
DWG DRAWING
DWTR DUMBWAITER
E EAST
E LABEL CLASS E DOOR
EA EACH
EAM EXCEPT AS NOTED
EAT ENTERING AIR TEMPERATURE
EF EACH FACE, EXHAUST FAN
EFF EFFICIENCY
EFS EXTERIOR FINISH SYSTEM
EG EXHAUST GRILLE
EIFS EXTERIOR INSULATION AND FINISH
SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELAST ELASTOMERIC
ELEC ELECTRIC
ELEC DR OP ELECTRIC DOOR OPENER
ELEV ELEVATOR
EMER EMERGENCY
EMER SHR EMERGENCY SHOWER
EMT ELECTRICAL METALLIC TUBING
ENCL ENCLOSURE
ENGR ENGINEER
ENVIR ENVIRONMENT
E/P EDGE OF PAVEMEMNT
EPA ENVIRONMENTAL PROTECTION AGENCY
EPDM ETHYLENE PROPYLENE DIENE
MONOMER
EPO EMERGENCY POWER OFF
EPS EXPANDED POLYSTYRENE BOARD
(INSULATION)
EQ EQUAL
EQL SP EQUALLY SPACED
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ER EXHAUST REGISTER
ERD EXISTING ROOF DRAIN
ESC ESCAPE OR ESCUTCHEON
ESCAL ESCALATOR
ESMT EASEMENT
ESP ESPECIALLY
EST ESTIMATE
ETC AND SO FORTH OR ET CETERA
EVAP EVAPORATIVE
EW EACH WAY
EWC ELECTRIC WATER COOLER
EWS EYE WASH STATION
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION OR EXPOSED
EXP BT EXPANSION BOLT
EXP JT EXPANSION JOINT
EXST GR EXISTING GRADE
EXT EXTERIOR, EXTERNAL, OR
EXTINGUISHER
EXT GR EXTERIOR GRADE
F FAHRENHEIT, FEMALE, FIRE, FUSE,
FILTER
FA FIRE ALARM
FAB FABRIC
FABX FIRE ALARM BOX
FAC FACTOR
FACIL FACILITY
FAS FASCIA
FAS BD FASCIA BOARD
FCO FLOOR CLEANOUT
FCTY FACTORY
FD FLOOR DRAIN, FIRE DAMPER
FDC FIRE DEPARTMENT CONNECTION
FDN FOUNDATION
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF&E, FFE FURNITURE, FIXTURE, AND EQUIPMENT
FH FLAT HEAD, FLAT HEAD SCREWS, FIRE
HYDRANT
FHC FIRE HOSE CABINET
FHMS FLAT HEAD MACHINE SCREW
FHP FULL HEIGHT PARTITION
FHWS FLAT HEAD WOOD SCREW
FIG FIGURE
FIL FILLET
FIN FINISH
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIN WD FINISH WOOD
FIXT FIXTURE
FJ FELT JOINT
FL FLOORLINE, FLOOR, FLASHING, FLOW LINE
FLASH FLASHING
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLR FLOOR
FLR FIN FLOOR FINISH
FLR SK FLOOR SINK
FLUOR FLUORESCENT
FLUOR FIX FLUORESCENT FIXTURE
FM FACTORY MUTUAL
FM-G FACTORY MUTUAL GLOBAL
FO FINISHED OPENING
FOC FACE OF CONCRETE OR FACE OF CURB
FOF FACE OF FINISH
FOM FACE OF MASONRY
4 WAY FOUR WAY
FOS FACE OF SLAB OR FACE OF STUD
FOUNT FOUNTAIN
FOW FACE OF WALL
FP FIRE PROTECTION OR FIREPROOF
FPH FROST PROOF HYDRANT
FPM FEET PER MINUTE
FPS FEET PER SECOND
FR FIRE RATING, FIRE RESISTANT, OR
FRAME
FR SNK FLUSHING RIM SINK
FREQ FREQUENCY
FRMG FRAMING
FRP FIBER REINFORCED POLYESTER OR
FIBERGLASS REINFORCED PLASTIC
FRZ FREEZER
FS FEDERAL SPECIFICATION, FULL SIZE
FSTNR FASTENER
FT FEET OR FOOT
FTG FOOTING
FURG FURRING
FURN FURNISH OR FURNITURE
FUT FUTURE
FW FIRE WATER
FWC FABRIC WALLCOVERING
G GROUND, GAS LINE, GRAM
GA GAGE OR GYPSUM ASSOCIATION
GAL GALLON, GALVANIZED
GALV GALVANIC OR GALVANIZED
GALV STL GALVANIZED STEEL
GB GRAB BAR
GC GENERAL CONTRACTOR, GLAZED
COATING
GD GUARD
GDR GUARD RAIL
GEN GENERAL OR GENERATOR
GFI GROUND FAULT INTERRUPT
GFMU GROUND FACE MASONRY UNIT
GFRC GLASS-FIBER-REINFORCED
CONCRETE
GFRG GLASS-FIBER-REINFORCED GYPSUM
GFRP GLASS-FIBER-REINFORCED PLASTIC
GI GALVANIZED IRON
GL GLASS
GLZ-C GLAZED BLOCK-CMU
GLZ-T GLAZED BLOCK-CLAY TILE
GL BLK GLASS BLOCK
GLU LAM GLUED LAMINATED WOOD
GR GRADE
GR FL GROUND FLOOR
GRAN GRANITE
GRTG GRATING
GSB GYPSUM SHEATHING BOARD
GSM GALVANIZED SHEET METAL
GSU GLAZED STRUCTURAL UNIT
GT GROUT
GUAR GUARANTEE
GUT GUTTER
GW GROUND WATER
GWB GYPUSM WALL BOARD
GYP GYPSUM
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H HIGH, HEIGHT, HUMIDIFIER
H PLAM HIGH PRESSURE PLASTIC LAMINATE
HAC HOUSEKEEPING AIDS CLOSET
HAZ MAT HAZARDOUS MATERIALS
HB HOSE BIBB
HC HOLLOW CORE, HANDICAPPED
HCWD HOLLOW CORE WOOD DOOR
HD HARD DRAWN
HDBD HARDBOARD
HDNR HARDENER
HDO HIGH DENSITY OVERLAY
HDR HEADER
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE AIR
(FILTER)
HEX HEXAGON
HF HIGH FREQUENCY
HGR HANGER
HGSW HORN GAP SWITCH
HID HIGH INTENSITY DISCHARGE
HM HECTOMETER
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HMDF HOLLOW METAL DOOR AND FRAME
HMF HOLLOW METAL FRAME
HNDRL HANDRAIL
HO HOLD OPEN
HORIZ HORIZONTAL
HOSP HOSPITAL
HP HIGH PRESSURE, HIGH POINT,
HORSEPOWER
HPS HIGH PRESSURE SODIUM
HQ HEADQUARTERS
HR HOUR
HS HEAT-STRENGTHENED (GLASS) OR HIGH
STRENGTH
HSE HOUSE
HSKPG HOUSEKEEPING
HST HOIST
HT HEIGHT
HVAC HEATING, VENTILATING, AND AIR
CONDITIONING
HVY HEAVY
HW HOT WATER, HEAD WALL
HYD HYDRANT
HYDR HYDRAULIC
HZ HERTZ
I INTERSTATE (HIGHWAY) OR MOMENT OF
INERTIA
IAQ INDOOR AIR QUALITY
IBC INTERNATIONAL BUILDING CODE
ID IDENTIFICATION, INSIDE DIAMETER, OR
INTERIOR DESIGN
ID NO IDENTIFICATION NUMBER
IE INVERT ELEVATION
ILLUM ILLUMINATION
IMC INTERMEDIATE METAL CONDUIT
INCL INCLUDED
IND INDEPENDENT OR INDUSTRIAL
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
INTERCOM INTERCOMMUNICATION
INTL INTERNATIONAL
INV INVERT
IP INLET PROTECTION
IRBF INDUSTRIAL RESIN BASE FLOORING
IRMA INVERTED ROOF MEMBRANE ASSEMBLY
IWH INSTANTANEOUS WATER HEATER
JAN JANITOR
J-BOX, JB JUNCTION BOX
JC JANITOR CLOSET
JCT JUNCTION
JT JOINT
JST JOIST
K KILO
KCP KEENE'S CEMENT PLASTER
KD KILN DRIED OR KNOCKED DOWN
KG KILOGRAM
KN KILONEWTON
KIT KITCHEN
KO KNOCKOUT
KPL KICKPLATE
KV KILOVOLT
KVA KILOVOLT-AMPERE
KW KILOWATT
L ANGLE, LOUVER, LENGTH, LENGTH OF
CURVE
LA LIGHTING ARRESTOR
LAB LABORATORY
LAD LADDER
LAM LAMINATE
LAM GL LAMINATED GLASS
LAU LAUNDRY
LAV LAVATORY
LBR LUMBER
LBS POUND
LC LEAD COVERED
LD BRG LOAD-BEARING
LDR LEADER
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LH LEFT HAND
LHR LEFT HAND REVERSE
LHR LEFT HAND REVERSE, LATENT HEAT
RATIO
LIB LIBRARY
LIN LINEAR
LINO LINOLEUM
LIQ LIQUID
LKR LOCKER
LKR RM LOCKER ROOM
LKWASH LOCKWASHER
LL LEAD LINED, LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LMST LIMESTONE
LNDSCP LANDSCAPE
LR LIVING ROOM
LRG LARGE
LRV LOUVERED ROOF VENT
LS LUMP SUM
L/S LITERS PER SECOND
LT LIGHT
LT GA LIGHT GAGE
LT WT LIGHTWEIGHT
LTG LIGHTING
LTNG LIGHTNING
LVC LENGTH OF VERTICAL CURVE
LVD LOUVERED
LVR LOUVER
LWC LIGHTWEIGHT CONCRETE
LWIC LIGHTWEIGHT INSULATING CONCRETE
LYR LAYER
M METER, MEGA
MACH MACHINE
MACH RM MACHINE ROOM
MAINT MAINTENANCE
MAN MANUAL
MAS MASONRY
MATL MATERIAL
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MB MACHINE BOLT
MCB METAL CORNER BEAD
MD METAL DECK
ME MECHANICAL ENGINEER
MEAS MEASURE
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MED MEDICAL, MEDIUM
MEK METHYL ETHYL KETONE
MEL MELAMINE
MEMB MEMBRANE
MEMO MEMORANDUM
MEZZ MEZZANINE
MF MILL FINISH
MFD MANUFACTURED
MFG MANUFACTURING
MFR MANUFACTURER
MFR REC MANUFACTURER'S RECOMMENDATION
MGT MANAGEMENT
MH MANHOLE
MIC MICROPHONE
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM MINUTE
MIN MINUTE MINIMUM
MIRR MIRROR
MISC MISCELLANEOUS
MIT MITER
MKR MARKER
ML METAL LATH
MLDG MOLDING (MOULDING)
MLO MAIN LUG ONLY
MLWK MILLWORK
mm MILLIMETER
MMP MEMBRANE WATERPROOFING
MO MASONRY OPENING OR MOTOR
OPERATED
MOD MODEL, MODIFY OR MODULE
MOD BIT MODIFIED BITUMEN
MON MONITOR
MOPR MOP RACK
MP MEDIUM PRESSURE
MR MOISTURE RESISTANT
MS MACHINE SCREW OR MOP SINK
M/S METERS PER SECOND
MTD MOUNTED
MTG MOUNTING
MTL METAL
MULL MULLION
MW MICROWAVE
MWP MEMBRANE WATERPROOFING
N NORTH
NA NOT APPLICABLE
NAAMM NATIONAL ASSOCIATION OF
ARCHITECTURAL METAL
MANUFACTURERS
NAT NATURAL
NATL NATIONAL
NC NOISE CRITERIA, NON-CORROSIVE
NCOMBL NONCOMBUSTIBLE
NDC NOSE DOWN CURB
NE NORTHEAST
NEC NATIONAL ELECTRICAL CODE
NEG NEGATIVE
NEMA NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION
NEUT NEUTRAL
NFC NATIONAL FIRE CODE
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NPS NOMINAL PIPE SIZE
NR NOISE REDUCTION
NRC NOISE REDUCTION COEFFICIENT
NRCA NATIONAL ROOFING CONTRACTORS
ASSOCIATION
NRP NON-REMOVABLE
NS NARROW STILE
NTS NOT TO SCALE
NUM NUMERAL
NW NORTHWEST
O/O OUT TO OUT
O OXYGEN
OA OUTSIDE AIR OR OVERALL
OC ON CENTER
OCB OIL CIRCUIT BREAKER
OCC OCCUPY
OCT OCTAGON
OD OUTSIDE DIAMETER OUTSIDE
DIMENSION
OD OUTSIDE DIMENSION OUTSIDE
DIAMETER
OF/CI OWNER FURNISHED/CONTRACTOR
INSTALLED
OFD OVERFLOW DRAIN
OFF OFFICE
OF/OI OWNER FURNISHED/OWNER INSTALLED
OH OVERHANG, OVERHEAD
OH DR OVERHEAD (COILING) DOOR
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
OPT OPTIONAL
OR OPERATING ROOM OR OUTSIDE RADIUS
ORD ORDNANCE OR OVERFLOW ROOF DRAIN
ORG ORGANIC
ORIG ORIGINAL
ORN ORNAMENTAL
OSD OPEN SITE DRAIN
OSHA OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION
OVHD OVERHEAD
OUT OUTLET
OZ OUNCE
P PIPE, POLE
Pa PASCALES
PA PUBLIC ADDRESS
PAR PARALLEL OR PARAPET
PARA PARAGRAPH
PART PARTIAL
PAT PATTERN
PB PUSHBUTTON, PULL BOX
PBD PARTICLEBOARD
PC PIECE, POLYCARBONATE OR PORTLAND
CEMENT
PCA PORTLAND CEMENT ASSOCIATION
PCC PRECAST CONCRETE
PCCP CONCRETE PAVEMENT
PCD PAPER CUP DISPENSER
PCF POUNDS PER CUBIC FOOT
PCP PORTLAND CEMENT PLASTER
PED PEDESTAL
PE PAINT EPOXY
PEN PENETRATE
PEND PENDANT
PERF PERFORATED
PERIM PERIMETER
PERP PERPENDICULAR
PGBD PEGBOARD
PHAR PHARMACY
PHOTO PHOTOGRAPH
PHS PHILLIPS HEAD SCREW
PI POINT OF INTERSECTION
PIV POST INDICATOR VALVE
PJF PREFORMED JOINT FILLER
PKG PACKAGE
PL PLASTIC LAMINATE,PROPERTY LINE,
PLATE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER OR PLASTIC
PLAS CMU PLASTER COVERED CMU
PLBG PLUMBING
PLYWD PLYWOOD
PMTL PAINTED METAL
PNEU PNEUMATIC
PNL PANEL
PO POST OFFICE, PURCHASE ORDER
PO PURCHASE ORDER POST OFFICE
POLY POLYETHYLENE (PLASTIC)
PR PAIR
PRCST PRECAST
PREFAB PREFABRICATE
PREFIN PREFINISH
PRELIM PRELIMINARY
PREP PREPARATION
PRESS PRESSURE
PREV PREVIOUS
PRIM PRIMARY
PRKG PARKING
PRMLD PREMOLDED
PROJ PROJECT
PROP PROPERTY
PRV PRESSURE RELIEF VALVE
PS PULL SWITCH
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT, PNEUMATIC TUBE, PRESSURE
TREATED, POINT OF TANGENT
PTD PAPER TOWEL DISPENSER
PTN PARTITION
PVC POLYVINYL CHLORIDE (PLASTIC), POINT
OF VERTICAL CURVE
PVG PAVING
PVI POINT OF VERTICAL INTERSECTION
PVT POINT OF VERTICAL TANGENT
PVMT PAVEMENT
PWR POWER
QA QUALITY ASSURANCE
QC QUALITY CONTROL
QRY QUARRY
QT QUARRY TILE
QTB QUARRY TILE BASE
QTF QUARRY TILE FLOOR
QTR QUARTER
QTY QUANTITY
QUAD QUADRANT
QUAL QUALITY
R RADIUS, RISER, RUBBER
RA RETURN AIR
RAD RADIATOR, RADIUS
RB RESILIENT BASE OR RUBBER BASE
RB HK ROBE HOOK
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RC REMOTE CONTROL
RCP REFLECTED CEILING PLAN, REINFORCED
CONCRETE PIPE
RCVR RECEIVER
RD ROAD OR ROOF DRAIN
REC RECESSED
RECD RECEIVED
RECPT RECEPTACLE
RECT RECTANGLE
RED REDUCING
REF REFERENCE OR REFRIGERATOR
REFR REFRACTORY, REFRIGERATION
REG REGISTER, REGULATOR
REINF REINFORCE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
RESIL T RESILIENT TILE
RET RETURN
REV REVISION
RF RADIO FREQUENCY, ROOF, RETURN FAN
RFG ROOFING
RFI REQUEST FOR INFORMATION
RFP REQUEST FOR PROPOSAL
RGS RIGID GALVANIZED STEEL
RH RIGHT HAND
RHC REHEAT COIL
RHMS ROUND HEAD MACHINE SCREW
RHR RIGHT HAND REVERSE
RHWS ROUND HEAD WOOD SCREW
RI RUBBER INSULATED
RL ROOF LEADER
RLG RAILING
RM ROOM
RND ROUND
RO ROUGH OPENING
ROW RIGHT OF WAY
RPM REVOLUTIONS PER MINUTE
RS ROUGH SAWN
RT RIGHT
RV ROOF VENT
RVS REVERSE
RVT RESILIENT VINYL TILE
RWD REDWOOD
RWL RAIN WATER LEADER
S SECOND, SOUTH, SANITARY, SEWER,
STRUCTURE, STAIN
SAB SOUND ATTENUATION BATT INSULATION
SA SUPPLY AIR
SALV SALVAGE
SAMP SAMPLE
SAN SANITARY SEWER
SAT SUSPENDED ACOUSTICAL TILE
SATC SUSPENDED ACOUSTICAL TILE CEILING
SB SPLASH BLOCK
SBS STYRENE BUTADIEN STYRENE
SBSTR SUBSTRATE
SC SEALED CONCRETE,SHADING
COEFFICIENT OR SOLID CORE
SCH SCHOOL, SCHEDULE
SCHED SCHEDULE
SCHEM SCHEMATIC
SCP SCUPPER
SCRN SCREEN
SCT STRUCTURAL CLAY TILE
SCWD SOLID CORE WOOD DOOR
SD SHOP DRAWINGS, SMOKE DETECTOR,
OR SOAP DISPENSER;
SDG SIDING
SE SOUTHEAST
SECT SECTION
SEG SEGMENT
SEL SELECT
SEP SEPARATE
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SG SUPPLY GRILLE
SGD SLIDING GLASS DOOR
1PH SINGLE PHASE
SGL SINGLE
SH SHEET
SHR SHOWER
SHR HD SHOWER HEAD
SHRD SHOWER DRAIN
SHT SHEET
SHT MTL FL SHEET METAL (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SJI STEEL JOIST INSTITUTE
SK SKETCH
SKCP SUSPENDED KEENE'S CEMENT PLASTER
SKLT SKYLIGHT
SL SLOPE
SLD WDW HORIZONTAL SLIDING WINDOW
SLDG SLIDING
SLNT SEALANT
SM SHEET METAL
SMH SANITARY MODULE
SMK SMOKE
SND SANITARY NAPKIN DISPENSER
SND INS SOUND INSULATION
SNDU SANITARY NAPKIN DISPOSAL UNIT
SP STATIC PRESSURE, SINGLE POLE
SPC SUSPENDED PLASTER CEILING
SPDT SINGLE POLE DOUBLE THROW
SPEC SPECIFICATION
SPKLR SPRINKLER
SPKR SPEAKER
SPST SINGLE POLE SINGLE THROW
SPLY SUPPLY
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SR SUPPLY REGISTER,SHEET RUBBER
SS SANITARY SEWER OR SERVICE SINK
SSF SOLID SURFACE FABRICATION
SST STAINLESS STEEL
ST STAIRS, STREET, SINGLE THROW
STA STATION
STC SOUND TRANSMISSION CLASS
STD STANDARD
STIF STIFFENER
STL STEEL
STL JST STEEL JOIST
STL LNTL STEEL LINTEL
STL PL STEEL PLATE
STL RF DK STEEL ROOF DECK
STL TB STEEL TUBE
STL TR STEEL TRUSS
STNLS STAINLESS
STOR STORAGE
STR STRINGERS
STRUCT STRUCTURAL
STRUCT STL STRUCTURAL STEEL
SUB SUBSTITUTE
SURF SURFACE
SUP SUPPORT
SUSP SUSPEND
SUSP CLG SUSPENDED CEILING
SV SHEET VINYL
SV B SHEET VINYL BASE
SW SWITCH, SIDE WALK
SWBD SWITCHBOARD
SWDR SWING DOOR
SWGR SWITCH GEAR
SYM SYMBOL
SYNTH SYNTHETIC
SYS SYSTEM
T TREAD, TILE, TOP, TANGENT
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
T&M TIME AND MATERIALS
TB THROUGH BOLT OR TOWEL BAR,TILE
BASE
TC TOP OF CURB
TCA TILE COUNCIL OF AMERICA
TCP TELEPHONE CONTROL PANEL
TEMPERATURE CONTROL PANEL;
TRAFFIC CONTROL PLAN
TD TOWEL DISPENSER
TECH TECHNICAL
TEL TELEPHONE
TEMP TEMPERATURE OR TEMPORARY
TER TERRAZZO
TERM TERMINAL
TH TOTAL HEAD (PUMPS)
THD THREAD
THERM THERMAL
THK THICKNESS
THRES THRESHOLD
THRSLD THRESHOLD
THRU THROUGH
THRUOUT THROUGHOUT
TK BD TACKBOARD
TMPD TEMPERED
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TO TOP OF ___
TO FDN TOP OF FOUNDATION
TOB TOP OF BEAM
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOS TOP OF STEEL
TOW TOP OF WALL
TPD TOILET PAPER DISPENSER
TPH TOILET PAPER HOLDER
TR TOWEL RACK, TOP REGISTER
TRANS TRANSOM, TRANSITION
TRANS WD FIN TRANSPARENT WOOD FINISH
TRTD TREATED
TS TENSILE STRENGTH, TUBE STEEL, TOP
OF STEEL, TOP OF STONE, TOP OF SLAB
TSTAT THERMOSTAT
TV TELEVISION
TYP TYPICAL
U HEAT TRANSFER COEFFICIENT
UC UNDERCUT
UCD UNDERCUT DOOR
UCF UNDER COUNTER FREEZER
UCR UNDER COUNTER REFRIGERATOR
UGE UNDERGROUND ELECTRIC
UGND UNDERGROUND
UGT UNDERGROUND TELEPHONE
UH UNIT HEATER
UL UNDERWRITERS LABORATORIES
ULT ULTIMATE
UNFIN UNFINISH
UNO UNLESS NOTED OTHER WISE
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
UR URINAL
UTIL UTILITY
UV ULTRAVIOLET
V VOLT, VENT, VALVE
VA VOLT AMPRE
VAC VACUUM
VAR VARIES
VB VINYL BASE
VC VARNISH CAMBRIC, VITRIFIED CLAY, VA
SUPPLIED & CONTRACTOR INSTALLED
VCT VINYL COMPOSITION TILE, VITRIFIED
CLAY TILE
VEH VEHICLE
VENT VENTILATION
VERT VERTICAL
VEST VESTIBULE
VFAT VINYL FACED ACOUSTICAL TILE
VIC VICINITY
VID VIDEO
VIF VERIFY IN FIELD
VNR VENEER
VOC VOLATILE ORGANIC COMPOUND
VOL VOLUME
VOLT VOLTAGE
VP VENEER PLASTER
VPI VERTICAL POINT OF INTERSECTION
VPOC VERTICAL POINT OF CURVE
VPOT VERTICAL POINT OF TANGENT
VR VAPOR RETARDER
VS VENT STACK
VTR VENT THROUGH ROOF
VV VA SUPPLIED & INSTALLED
VWC VINYL WALL COVERING
VWF VINYL WALL FABRIC
W WIDE, WEST, WIDTH, WASTE, WATER,
WATT, WIRE
W/ WITH
W/O WITHOUT
WA WATT
WARR WARRANTY
WB WET BULB
WBL WOOD BLOCKING
WC WALL COVERING OR WATER CLOSET
WC WL HNG WATER CLOSET, WALL HUNG
WCHR WATER CHILLER
WCL WL MTD WATER COOLER, WALL HUNG
WD WOOD, WINDOW DIMENSION
WDW WINDOW
WF WIDE FLANGE
WFAB WALL FABRIC
WFR WOOD FRAME
WFS WOOD FURRING STRIPS
WH WATER HEATER
WHSE WAREHOUSE
WL WATER LEVEL
WLD WELDED
WM WIRE MESH
WOM WALK OFF MATT
WP WATERPROOFING, WEATHERPROOF
WPD WATER PRESSURE DROP
WPM WATERPROOF MEMBRANE
WR WEATHER RESISTANT
WS WEATHERSTRIP, WASTE STACK, WATER
SURFACE, WATERSTOP
WSCT WAINSCOT
WT WEIGHT OR WALL TILE
WWF WELDED WIRE FABRIC
X BRACE CROSS BRACE
XFMR TRANSFORMER
XPS EXTRUDED POLYSTYRENE BOARD
(INSULATION)
X-STR EXISTING STRUCTURE
YD YARD
YR YEAR
ARCHITECTURAL SYMBOLS
COLUMN GRID LINE
(EXISTING)
EXISTING TO REMAIN
EXISTING TO BE REMOVED
EXISTING TO REMAIN
NEW CONSTRUCTION
ROOM TAG
ROOM NAME
ROOM NUMBER
DOOR NUMBER
SYMBOL AND MINIMUM
CLEARANCES
WALL LEGEND
AREA OR VOLUME
DETAIL - SECTION
POSITION ON SHEET
SHEET NUMBER
DETAIL - PLAN/ RCP
POSITION ON SHEET
SHEET NUMBER
BUILDING SECTION
POSITION ON SHEET
SHEET NUMBER
WALL SECTION
POSITION ON SHEET
SHEET NUMBER
EXTERIOR ELEVATION
POSITION ON SHEET
SHEET NUMBER
INTERIOR ELEVATION
POSITION ON SHEET
SHEET NUMBER
WALL TYPE TAG
FRAME TYPE -
EXTERIOR & LOUVER
DRAWING NUMBER
DRAWING SCALE
VIEW TITLE
KEYNOTE
DRAWING REVISION
LEVEL DATUM
LEVEL NAME
LEVEL ELEVATION
NORTH ARROW
FRAME TYPE - INTERIOR
GRAPHIC SCALE
0 4'-0" 8'-0" 16'-0"
PLAN
NORTH
18" MIN.
12" MIN. 4" MIN.
1A
≠ X# X X
XX
XX
X
Name Elevation
SIM
X-XXX
X
SIM
X-XXX
X
XXXX
X
X X
X
A-1 1/8" = 1'-0"
View Name
ROOM
NAME
150 SF
7'-0"
R 3'-11"
100°
DIMENSION TO FACE OF
FINISH, FACE OF CONCRETE,
COLUMN CENTERLINE, OR AS
NOTED.
CENTERLINE
COLUMN GRID LINE
(NEW)
MATCHLINE
SEE: X/X-XXX
X
SEE: (X/X-XXX)
VIEW REFERENCE FOR
ADDITIONAL INFORMATION
REFERENCE TO AREA
MATCHLINE AND VIEW REFERENCE
SIM
X
X-XXX
SIM
X
X-XXX
SIM
X
X-XXX
X
X-XXX
SIM
XXX FURNITURE, FIXTURE, &
EQUIPMENT INDICATOR
RCP SYMBOL LEGEND
RECESSED OR SURFACE MOUNTED LIGHT FIXTURE
LINEAR WALL WASH LUMINAIRE, MOUNTED WITHIN
ARCHITECTURAL COVE
SPEAKER
HVAC SUPPLY DIFFUSER
HVAC RETURN DIFFUSER
RADIANT HEAT PANEL
EXIT LIGHT
HVAC EXHAUST DIFFUSER
LINEAR LUMINAIRE, WALL MOUNTED
(INDICATES DIRECTION OF LIGHT DISTRIBUTION.)
CHANDELIER, PENDANT MOUNTED
LINEAR LUMINAIRE, PENDANT MOUNTED
STRIP OR TURRET LUMINAIRE, PENDANT MOUNTED
STRIP OR TURRET LUMINAIRE, SURFACE MOUNTED
(INDICATES DIRECTION OF LIGHT DISTRIBUTION.)
RECESSED OR SURFACE MOUNTED SQUARE
DOWNLIGHT LUMINAIRE
RECESSED OR SURFACE MOUNTED ROUND
DOWNLIGHT LUMINAIRE
RECESSED OR SURFACE MOUNTED LIGHT FIXTURE
ACOUSTICAL TILE CEILING (24X24)
GYPSUM CEILING - PAINTED
HIGH DEFINITION RECEIVERHDR
ANALOGUE SATELLITE RECEIVERASR
TELEVISION OUTLETTV
LUMINAIRE CEILING- SEE ELECT FOR SIZE
S
MATERIALS LEGEND
CONCRETE (SECTION)
GRANULAR FILL
CONCRETE MASONRY UNITS
BRICK
RIGID INSULATION (SECTION)
ACOUSTIC/THERMAL INSULATION (SECTION)
DIMENSIONAL LUMBER
CONTINUOUS (SECTION)
DIMENSIONAL LUMBER BLOCKING
(SECTION)
STEEL (SECTION)
ALUMINUM (SECTION)
WOOD FINISH (SECTION)
LUMBER FINISH (SECTION)
EARTHWORK (SECTION)
STUD WALL (PLAN & SECTION)
EXISTING WALL TO REMAIN (PLAN & SECTION)
DEMOLISHED WALL (PLAN & SECTION)
MINERAL WOOL INSULATION (SECTION)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
C
Phase
ARCHITECT OF RECORD STAMPENGINEERS OF RECORD
321 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
A/E:
C on e ei gh th in ch o ne fo ot
B
A
C
D
E
F th re e in ch es o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot on e ha lf in ch o ne fo ot
6"
6"
6"
6"
C :\r vt \2
6\
8 3
-A
-C E
N T
R A
L_ V
I S N
-1
-4 th F lo or
_ M
IN
E
LS
O N
.r vt
C :\r vt \2
6\
8 3
-A
-C E
N T
R A
L_ V
I S N
-1
-4 th F lo or
_ M
IN
E
LS
O N
.r vt
/1
/2
:2
:4
P
M
G-101
ABBREVIATIONS, SYMBOLS, &
GENERAL NOTES
610-17-101
03/19/18 MN RG
ISSUED FOR
CONSTRUCTION
Project Director
1700 E. 38TH STREET MARION, IN 46953
VISN 11 MARION B-138: 4TH FLOOR
CONSTRUCTION
SPRINKLERED
HDR ARCHITECTURE, INC.
600 HENNEPIN AVE SUITE 260
MINNEAPOLIS, MN 55403
612.524.6000
TERRY LITTELL SR., RA,
LEED AP
KORDA, INC.
1650 WATERMARK DRIVE, SUITE 200
COLUMBUS, OH 43215
614.487.1650
STAN KMONK
METRIC ENVIRONMENTAL
6971 HILLSDALE COURT
INDIANAPOLIS, IN 46250
FLOOR PLAN GENERAL NOTES:
1. GENERAL NOTES APPLY TO ALL DRAWING SETS.
2. SUBCONTRACTORS FOR EACH TRADE ARE ADVISED THAT
INFORMATION PERTINENT TO THEIR WORK MAY OCCUR IN
OTHER PORTIONS OF THE CONTRACT DOCUMENTS. ALL
NOTES ARE TO BE REVIEWED AND APPLIED TO RELATED
BUILDING DOCUMENTS.
3. FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS.
IF INCONSISTENCIES, CONTRADICTIONS OR OMISSIONS ARE
DISCOVERED FOLLOW PROCEDURES LISTED IN SECTION 01 26
13 REQUESTS FOR INFORMATION (RFI) BEFORE AND/OR
DURING CONSTRUCTION.
4. CROSS REFERENCES SHOWN ON DRAWINGS DO NOT
NECESSARILY INDICATE ALL LIKE CONDITIONS AND DO NOT
LIMIT APPLICATION OF ANY DRAWING OR DETAIL. WHERE
SPECIFIC DIMENSIONS, DETAILS, OR DESIGN INTENT CANNOT
BE DETERMINED, FOLLOW PROCEDURES LISTED IN SECTION 01
26 13 REQUESTS FOR INFORMATION (RFI) PRIOR TO
PROCEEDING WITH WORK.
5. REVIEW SPECIFICATIONS FOR INSTRUCTIONS NOT SHOWN
ON DRAWINGS. INFORMATION COMMON TO SEVERAL
DRAWINGS MAY BE NOTED ON ONLY ONCE. CONTRACTORS
ARE RESPONSIBLE FOR ENTIRE SET OF DOCUMENTS.
6. PATCH ALL HOLES IN EXISTING SURFACES AND WHERE
EQUIPMENT HAS BEEN REMOVED OR DEMOLITION HAS
OCCURRED AND PREPARE WALL SURFACES (PATCH, SKIM
COAT, PAINT AND FINISH TO MATCH ADJACENT SURFACES) AS
REQUIRED IN PREPARATION FOR NEW FINISHES SCHEDULED.
PATCH TO MATCH ADJACENT SURFACES IF NOT SCHEDULED.
THIS APPLIES TO CEILINGS, BULKHEADS, FLOORING, BASE, ETC.
7. DIMENSIONS ARE TO STRUCTURAL GRIDLINE OR FACE OF
FINISHED WALL UNLESS NOTED OTHERWISE.
8. PROVIDE METAL BACKING AND/OR METAL BLOCKING IN
WALLS AS REQUIRED AT ALL WALL-MOUNTED ITEMS. VERIFY
HEIGHT AND LENGTH WITH ACTUAL EQUIPMENT. REFER TO
METAL BACKING AND BLOCKING DETAILS ON SHEET A-702. AT
EXISTING WALLS, REMOVE WALL MATERIAL TO INSTALL METAL
BACKING/BLOCKING FOR NEW WALL-MOUNTED ITEMS.
9 ALL EXISTING FLOOR AND WALL OPENINGS AND
DEPRESSIONS NOT USED IN THE NEW WORK SHALL BE FILLED
OR CLOSED WITH MATERIALS TO MEET REQUIRED FIRE RATING
AND MATCH ADJACENT FINISHES.
10. DRAWINGS ARE NOT TO BE SCALED. CONTRACTOR TO
VERIFY ALL DIMENSIONS AND FIELD CONDITIONS PRIOR TO
COMMENCING THE WORK.
11. COORDINATE WITH INTERIORS SHEETS FOR CORNER
GUARD AND WALL PROTECTION LOCATIONS AND DETAILS.
12. RADIUS EXPOSED COUNTERTOP CORNERS 2" RADIUS,
TYPICALLY. (2" WHERE 3MM EDGE BANDING, 1" RADIUS AT
PLAM EDGES.) SEE CASEWORK DETAILS.
13. CAULK ALL COUNTERTOPS, BACK SPLASHES AND CABINETS
AT LOCATIONS WHERE THEY MEET WALLS. SEAL ALL CUT-
OUTS IN COUNTERTOPS.
14. ALL CUTTING AND PATCHING REQUIRED FOR NEW
MECHANICAL AND ELECTRICAL WORK IN ALL EXISTING SPACES
SHALL BE BY THE RESPECTIVE CONTRACTORS.
15. MATCH ALL FINISHED WALL THICKNESS WHERE NEW WALLS
OCCUR IN LINE WITH EXISTING WALLS WHILE MAINTAINING
REQUIRED WALL RATING.
16. CONTRACTOR TO PROVIDE FIRE, SMOKE, DIRT, DUST &
NOISE CONTAINMENT BARRIERS BETWEEN THE WORK AREA &
THE ADJACENT OCCUPIED SPACES.
17. ALL PIPING, CONDUITS, AND RELATED MECHANICAL AND
ELECTRICAL ITEMS SHALL BE CONCEALED WITHIN DRYWALL
AND/OR PLASTER FURRING AS REQUIRED IN FINISHED AREAS
WHETHER SHOWN ON DRAWINGS OR NOT UNLESS OTHERWISE
NOTED.
18. SEAL AROUND ALL MECHANICAL AND ELECTRICAL
EQUIPMENT PENETRATIONS AT RATED WALLS, ABOVE AND
BELOW CEILINGS, WITH A UL APPROVED FIRE-STOPPING
MATERIAL.
19. ALL INTERIOR WALLS WILL BE TYPE 'A' CONSTRUCTION
UNLESS OTHERWISE INDICATED. ALL FRAMING AROUND
COLUMNS WILL BE TYPE 'J2' CONSTRUCTION UNLESS
OTHERWISE INDICATED. REFER TO REGULATORY PLAN
SHEETS GI104 FOR WALL RATINGS.
20. WHEN WALL PARTITIONS OF DIFFERENT FIRE RATING
INTERSECT, THE HIGHEST RATED PARTITION TAKES
PRECEDENT.
21. ALL EXISTING TO REMAIN CEILING AND WALL GRILLES,
DIFFUSERS AND LIGHTS, SPRINKLER HEADS, OCCUPANCY AND
FIRE ALARM DETECTORS TO BE CLEANED IN AREAS OF
CONSTRUCTION.
22. VERIFY THAT THE EXISTING WALLS REQUIRING FIRE
RATING ARE MAINTAINED, REPAIRED AND EXTENDED TO
STRUCTURE.
23. REFER TO LIFE SAFETY PLANS AND FLOOR PLANS FOR
LOCATION OF REQUIRED WALL RATINGS.
24. ALL THERMOSTAT LOCATIONS TO BE COORDINATED WITH
COR PRIOR TO INSTALLATION.
1. CONTRACTOR SHALL MAKE PROVISIONS TO ENSURE
CONSTRUCTION NOISE DOES NOT EXCEED THE OSHA
THRESHOLD IN AREAS ADJACENT TO CONSTRUCTION.
2. COMPLAINTS BY PATIENTS OR EMPLOYEES SHALL BE
DIRECTED TO THE FACILITY SAFETY OFFICE. THE SAFETY
OFFICE SHALL INVESTIGATE THE COMPLAINTS AND MAKE
RECOMMENDATIONS TO THE CONTRACTING OFFICER
REPRESENTATIVE ON HOW TO PROCEED WITH THE TASK.
3. CONTRACTOR SHALL CONDUCT HIGH NOISE ACTIVITIES IN A
WAY TO ALLOW THE FACILITY TO OPERATE DURING
CONSTRUCTION. ACTIONS THAT THE CONTRACTOR SHALL
TAKE TO MINIMIZE IMPACT INCLUDE:
a. NOTIFYING THE COR TWO DAYS PRIOR TO TIME OF HIGH
NOISE PRODUCING ACTIVITIES WHICH ARE TO BE COMPLETED
BETWEEN THE HOURS OF 5:00 PM AND 6:00 AM.
b. SCHEDULING HIGH NOISE ACTIVITIES DURING TIMES OF
MINIMAL IMPACT.
NOISE LEVEL
REGULATION:
9. ALL GWB SOFFITS, CEILINGS & BULKHEADS TO RECEIVE
DESIGNATED CEILING PAINT.
8. VERIFY CEILING HEIGHTS WITH STRUCT, AND DUCTWORK.
7. REFER TO AC100 SERIES SHEETS FOR CEILING DESIGNATIONS
AND 09 06 00 FOR CEILING AND GRID INFORMATION.
6. ALTHOUGH NOT SPECIFICALLY SHOWN, THE ENTIRE PROJECT
HAS FIRE SPRINKLER HEADS IN CEILING. SCRIBE CEILING
MATERIALS CARFULLY FOR A TIGHT FIT.
5. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES
OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.
SCRIBE CEILING MATERIALS CAREFULLY.
4. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE
OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
3. PROVIDE GYPSUM WALL BOARD AND STUD BULKHEADS
WHERE CEILINGS OF DIFFERENT HEIGHTS ABUT. DO NOT
BUILD BULKHEADS OF ACOUSTICAL CEILING MATERIAL UNLESS
SPECIFICALLY DETAILED.
2. ALL CEILINGS TO BE 9'-0" AFF UNLESS NOTED OTHERWISE.
1. REFER TO CEILING PLAN AND SPECIFICAITON SECTION 09 06 00
FOR CEILING FINISH INFORMATION.
REFLECTED CEILING PLAN
GENERAL NOTES
Mark: Revision: Date:
ISSUED FOR CONSTRUCTION 03/19/2018
03-19-18
(BUSINESS) 841 SF
(BUSINESS) 9248 SF
1A
1B
1B
1B
1B 1C
(BUSINESS) 2081 SF
(AMBULATORY HEALTH CARE) 7797 SF1A
STAIRCASE
STAIRCASE
STAIRCASE
1A
COMMON PATH OF TRAVEL
1D
1D
COMMON PATH OF TRAVEL
COMMON
PATH OF
TRAVEL
1C
1E
1C
1E
(ASSEMBLY) 130 SF
(ASSEMBLY) 194 SF
(ASSEMBLY) 567 SF
(ASSEMBLY) 310 SF
140 SF
OFFICE
140 SF
OFFICE
119 SF
CT, CONE
BEAM
125 SF
STOR.
STER.
INST.
247 SF
CLEAN
163 SF
ORAL
SURG.
67 SF
SCRUB
301 SF
CORR.
163 SF
ORAL
SURG.
215 SF
SOIL UTIL.
143 SF
STOR.,
DENTAL
SUPP.
56 SF
WORK,
STF.
DENTIST 142 SF
OFFICE,
DENTAL
CHIEF
55 SF
TLT,
STAFF 202 SF
LAB, GEN.
59 SF
DENTAL
TECH.
129 SF
LOUNGE
88 SF
M-LOCKER
85 SF
W-LOCKER
105 SF
EQ. MECH.
52 SF
HAC
23 SF
SUB-WAIT
109 SF
DTR
147 SF
DTR,
SPECIAL
484 SF
CORR.
171 SF
DTR
158 SF
DTR
154 SF
DTR
134 SF
DTR
49 SF
S/WAITING
133 SF
DTR
516 SF
SHELL
204 SF
OIT
36 SF
ELEC
53 SF
HAC
59 SF
RECEP.
100 SF
PRETEST
135 SF
EXAM,
OPT.
119 SF
EXAM,
OPTH.
123 SF
EXAM,
OPT.
126 SF
EXAM,
OPT.
101 SF
DIL. WAIT
113 SF
PRETEST
116 SF
PRETEST
31 SF
W.C. ALC.
125 SF
PAT. ED.
127 SF
CLN SUP
128 SF
VISUAL
FIELDS
161 SF
US / OPT.
COH.
97 SF
STOR. EQ.
105 SF
SOIL UTIL.
149 SF
PHOTO
96 SF
CLERICAL
171 SF
LOUNGE
47 SF
TLT,
STAFF
50 SF
EYE PROV.
84 SF
OFC,
OPTH./OPT.
CHIEF
106 SF
OFC, OPT.
CHIEF
101 SF
OFC,
OPTH.
CHIEF
166 SF
OIT
132 SF
EXAM
129 SF
EXAM
132 SF
EXAM
132 SF
OFC, AUD.
CHIEF
62 SF
AUDIO
CONTROL
64 SF
AUDIO
EXAM
64 SF
AUDIO
EXAM
70 SF
AUDIO
CONTROL
51 SF
AUDIO
EXAM
58 SF
AUDIO
CONTROL
136 SF
CERUMEN
MGMT.
77 SF
TLT, PAT.
104 SF
STOR. EQ.
121 SF
EXAM
TECH.
129 SF
LOUNGE
183 SF
HEARING
AID FAB.
161 SF
INST. CAL.
117 SF
REC. 122 SF
WAITING
80 SF
RECEP.
198 SF
EYE WAIT
1442 SF
CORR
38 SF
W.C. ALC.
120 SF
RECEP.
285 SF
CONF.
174 SF
TLT
166 SF
TLT
793 SF
CORR.
140 SF
FITTING
547 SF
WAITING
'-4
Occupancy Classification
(NFPA) AMBULATORY
HEALTH CARE
(NFPA) ASSEMBLY
(NFPA) BUSINESS
UP
'-2
27'-6 1/2"
533 SF
CORR.
P:40.50 R:33.75
P:80.50 R:33.75
P :8
.5
R
:3 .7
P :8
.5
R
:3 .7
P :8
.5
R :3
.7
P:80.50 R:33.75
P:41.75 R:33.75
P:80.50 R:33.75
MATCHLINE
MATCHLINE
P H
A S
E
P H
A S
E
P H
A S
E
P H
A S
E
FEC-1
FEC-1
1F
45 SF
STOR. EQ.
'-1
1/
4"
P:41.75 R:33.75
P:41.75 R:33.75
P :8
.5
R
:3 .7
P :8
.5
R
:3 .7
P :8
.5
R
:3 .7
453D453D
CLOSET
53 SF
WORK,
STF.
DENTIST
S
F
W O
R K
S
T F
D
E N
T
IS
T
S
F E
Q
S
F C
L E
R
IC
A L
50 SF
EYE PROV.
S
F E
Y E
P R
O V
S
F
C T
C O
N T
R O
L
47 SF
LAB, ACR.
FINISH
136 SF
LAB, SHIP/
REC.
56 SF
DENTAL
TECH.
54 SF
DENTAL
TECH.
PATIENT CARE NON-SLEEPING
SUITE 1,040 SQ FT.
NON-PATIENT CARE
SUITE 2,125 SQ FT.
'-7
/4
PATIENT CARE NON-SLEEPING SUITE
2,096 SQ FT.
1 HOUR SEPARATED PER 20.3.2.4
NIC
54 SF
TLT, PAT.
67 SF
SUB-WAIT
(ASSEMBLY) 393 SF
475A475A
WAITING
LIFE SAFETY SYMBOLS
XXXX PATH OF TRAVEL
(FOR CUMULATIVE DISTANCES REFER
TO SCHEDULE)
EXIT LIGHTING
XXX
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHERS
FIRE HOSE CABINETS
DIRECTION OF EGRESS
WIDTH PROVIDED
P: XX"
R: XX"
1A
WIDTH REQUIRED
THIS PROJECT HAS BEEN ● INTERNATIONAL BUILDING CODE
DESIGNED UNDER THE 2015 - CURRENT EDITION INCLUDING
REQUIREMENTS OF THE ● NFPA 101 LIFE SAFETY CODE 2015 EDITION
APPLICABLE CODES: ● ARCHITECTURAL BARRIERS ACT &
VA PG18-13 BARRIER FREE
● US DEPARTMENT OF VETERANS AFFAIRS
DESIGN MANUAL AND STANDARDS
ADDITIONAL REFERENCED CODES, DOCUMENTS
AND STANDARDS AS NOTED IN SPECIFICATION
SECTION 01 00 00
OWNER: VETERANS ADMINISTRATION
MARION CAMPUS
ARCHITECT: HDR Architecture, Inc.
600 Hennepin Avenue, Ste. 260 Minneapolis, MN 55403
LIFE SAFETY FEATURES:
FIRE SUPPRESSION SYSTEM - SPRINKLED
FIRE EXTINGUISHERS THROUGHOUT
CODE PLAN GENERAL NOTES:
1. SEE ELECTRICAL PLANS FOR EXIT LIGHTING LOCATIONS.
2. SEE MECHANICAL PLANS FOR FIRE SPRINKLER SERVICE.
BUILDING 138: EXISTING CONSTRUCTION:
Occupancy - (CH 20.) AMBULATORY CARE CENTER, (CH 38.) BUSINESS, &(CH 40.) INDUSTRIAL Construction Type IB (I-222) Construction Sprinklers complying with NFPA 13.
Allowable Area:
B: UNLIMITED
Actual Area Sq Ft:
Level 4: B: 21533 Allowable Number of Stories: Per Areas in table
B: 12 Allowable Height: 160'-0" Actual Number of Stories: 4 Actual Height: 51'-6"
SMOKE COMPARTMENTS NOT REQUIRED PER 20.3.7.2 (2).
INCIDENTAL USE SEPARATIONS PER MOST RESTRICTIVE CODE (18.3.2.1.2 BECAUSE OF USE OF SUITES)
OCCUPANT LOAD: SEE AREA SCHEDULE
PLUMBING FIXTURES: TOTAL OCCUPANT LOAD IS 254
235/2 = 118:
B OCCUPANCY -
1 PER 25 FOR FIRST 50, 1 PER 50 FOR REMAINDER
127=2 + 2 = 4 PER GENDER
DRINKING FOUNTAIN: 1 PER 100: 3 REQUIRED
BUSINESS:
COMMON PATH OF TRAVEL: >100 FT
TRAVEL DISTANCE TO EXITS: >300 FT
DEAD END CORRIDOR: >50 FT
INDUSTRIAL USE: SPECIAL PURPOSE INDUSTRIAL
COMMON PATH OF TRAVEL: >100 FT
TRAVEL DISTANCE TO EXITS: >400 FT
DEAD END CORRIDOR: >50 FT
AMBULATORY HEALTH CARE:
COMMON PATH OF TRAVEL: >100 FT
TRAVEL DISTANCE TO EXITS: >200 FT
DEAD END CORRIDOR: >50 FT
FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS
(IBC TABLE 601) FOR TYPE I-B (I-222) CONSTRUCTION TYPE
B -AMBULATORY CARE CENTER
Structural Frame 2 Hour Bearing Walls (Exterior) 2 Hour Bearing Walls (Interior) 2 Hour Non Bearing Walls (Exterior 10 < X < 30 ) 0 Hour Non Bearing Walls (Interior) 0 Hour Floor Construction 2 Hour
(Including supporting beams and joists) Roof Construction 1 Hour
(Including supporting beams and joists)
Per footnote d at IBC Table 601, ratings can be reduced by 1 hour if an approved sprinkler system is provided.
SUITES PER HEALTH CARE CH. 18:
PATIENT CARE NON-SLEEPING SUITE:
COMMON PATH OF TRAVEL: >100 FT
TRAVEL DISTANCE TO EXITS: >200 FT
NON-PATIENT CARE NON-SLEEPING SUITE:
SAME AS AMBULATORY HEALTHCARE
(INDUSTRIAL) 2068 SF
(INDUSTRIAL) 1368 SF(INDUSTRIAL) 1368 SF
Occupancy Classification
(NFPA)
INDUSTRIAL
EAST
PENTHOUSE
P2
1052 SF
EXISTING
PENTHOUSE
2164 SF
WEST
PENTHOUSE
P1
1069 SF
1H
1G
1G
MATCHLINE
MATCHLINE
P H
A S
E
P H
A S
E
P H
A S
E
P H
A S
E
0 8'-0" 16'-0" 32'-0"
PLAN
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
C
Phase
ARCHITECT OF RECORD STAMPENGINEERS OF RECORD
321 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
A/E:
C on e ei gh th in ch o ne fo ot
B
A
C
D
E
F th re e in ch es o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot on e ha lf in ch o ne fo ot
6"
6"
6"
6"
C :\r vt \2
6\
8 3
-A
-C E
N T
R A
L_ V
I S N
-1
-4 th F lo or
_ M
IN
E
LS
O N
.r vt
C :\r vt \2
6\
8 3
-A
-C E
N T
R A
L_ V
I S N
-1
-4 th F lo or
_ M
IN
E
LS
O N
.r vt
/1
/2
:2
:0
P
M
GI-104
LIFE SAFETY 610-17-101
03/19/18 ED MN
ISSUED FOR
CONSTRUCTION
Project Director
1700 E. 38TH STREET MARION, IN 46953
VISN 11 MARION B-138: 4TH FLOOR
CONSTRUCTION
SPRINKLERED
HDR ARCHITECTURE, INC.
600 HENNEPIN AVE SUITE 260
MINNEAPOLIS, MN 55403
612.524.6000
TERRY LITTELL SR., RA,
LEED AP
KORDA, INC.
1650 WATERMARK DRIVE, SUITE 200
COLUMBUS, OH 43215
614.487.1650
STAN KMONK
METRIC ENVIRONMENTAL
6971 HILLSDALE COURT
INDIANAPOLIS, IN 46250
1" = 10'-0" F1
FOURTH FLOOR LIFE SAFETY
EGRESS TRAVEL DISTANCES
Path ID Travel Distance
1A 101' - 1"
1B 118' - 11"
1C 107' - 0"
1D 70' - 3"
1E 78' - 9"
1F 46' - 8"
1G 247' - 4"
1H 92' - 4"
4TH FLOOR AREA SCHEDULE
OCCUPANCY
CLASSIFICATIONS AREA
SF PER
OCCUPANT OCCUPANCY LOAD
(NFPA) ASSEMBLY 393 SF
: 1 393 SF 0
(NFPA) BUSINESS 841 SF 100 SF 8
(NFPA) BUSINESS 9248 SF 100 SF 92
(NFPA) BUSINESS 2081 SF 100 SF 21
(NFPA) AMBULATORY
HEALTH CARE
7797 SF 150 SF 52
1: 4 19968 SF 173
(NFPA) ASSEMBLY 130 SF 15 SF 9
(NFPA) ASSEMBLY 194 SF 15 SF 13
(NFPA) ASSEMBLY 567 SF 15 SF 38
(NFPA) ASSEMBLY 310 SF 15 SF 21
2: 4 1201 SF 81
Grand total: 9 21562 SF 254
REQUIRED TOTAL STAIR DOOR EGRESS WIDTH: 76"
PROVIDED AT EACH EXIT: 36"
TOTAL PROVIDED: 108"
REQUIRED CORRIDOR WIDTH:
76" PROVIDED:
96"
FIELD VERIFY THE DOORS
1" = 10'-0" C1
PENTHOUSE PLAN LIFE SAFETY
PENTHOUSE AREA SCHEDULE
OCCUPANCY
CLASSIFICATIONS AREA NAME
SF PER
OCCUPANT OCCUPANCY LOAD
(NFPA) INDUSTRIAL 2068 SF EXISTING
PENTHOUSE
0 SF
(NFPA) INDUSTRIAL 1368 SF EAST PENTHOUSE 0 SF
(NFPA) INDUSTRIAL 1368 SF WEST PENTHOUSE 0 SF
: 3 4805 SF 0
PARTITION RATING GRAPHICS:
4 HR FIRE BARRIER
3 HR FIRE BARRIER
2 HR FIRE & SMOKE BARRIER
2 HR FIRE BARRIER
2 HR FIRE BARRIER/SHAFT
1 HR FIRE & SMOKE BARRIER
1 HR FIRE BARRIER
1 HR FIRE BARRIER/SHAFT
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION: PRIORITY
1 HIGHEST
5 LOWEST
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE
AND SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH
PATTERNS.
N/A__
N/A__
N/A__
Mark: Revision: Date:
ISSUED FOR CONSTRUCTION 03/19/2018
400B400B
CORR.
400E400E
CORR.
PHASE 1 DUMPSTER
CHUTE
PHASE 2 DUMPSTER
CHUTE
400A400A
CORR
400H400H
CORR.
400G400G
CORR.
400F400F
CORR.
400I400I
CORR.
400J400J
CORR
STICKY MAT: PROVIDE NEW
REGULARLY WHEN OLD IS SPENT
STICKY MAT: PROVIDE NEW
REGULARLY WHEN OLD IS SPENT
1 HR RATED WALL PARTITION
BETWEEN PHASES IS TO BE BUILT AS
THE FINAL WALL RATHER THAN A
TEMPORARY WALL PARTITION.
REMOVE AND REAPPLY GYPSUM
BOARD AT END OF MOST RECENTLY
COMPLETED PHASE.
TEMPORARY DOOR. FINAL
TO BE INSTALLED AT END
OF PHASE 2. FLIP DOOR AND
FRAME BETWEEN PHASES
MATCHLINE
MATCHLINE
P H
A S
E
P H
A S
E
P H
A S
E
P H
A S
E
ALTNERATE
DUMPSTER CHUTE
LOCATION
PHASE 1 DUMPSTER
CHUTE
PHASE 2 DUMPSTER
CHUTE
'-0
FIELD VERIFY DISTANCE TO PARKING LOT EDGE. EXTEND PAD TO EDGE OF LOT.
50'-0"
400C400C
CORR.
400D400D
CORR.
9' -0
29'-7"
E3
GI-204
TEMPORARY WALL
FLOOR LINE
CEILING SYSTEM AS
SCHEDULED
EXISTING STRUCTURE
FIRE RATED PLASTIC TO
PREVENT DUST INSTALL
PRIOR TO
CONSTRUCTION
/1
F
IN
IS
H
E D
F L O
O R
T O
U N
D E
R S
ID
E
O F
S T
R U
C T
U R
E
V E
R
IF
Y F
L O
O R
T O
F L O
O R
H E
IG
H
T
RENOVATED SPRINKLER SYSTEM
WEEKLY CHANGED OR
MORE AS NEEDED
PRE_FILTER
FLEX DUCT
MONTHLY CHANGED
HEPA FILTER
HEPA NEGATIVE AIR
UNIT
PROVIDE STICKY MATS (CHANGED END OF
EVERY SHIFT OR MORE IF NECESSARY TO
MAINTAIN CLEANLINESS).
PROVIDE STICKY MATS (CHANGED END OF
EVERY SHIFT OR MORE IF NECESSARY TO
MAINTAIN CLEANLINESS).
INDICATOR SHALL BE AT 0.01 OR GREATER (VERIFY DAILY). IF NOT VERIFY ALL
OPENING SUCH AS DOOR ARE CLOSED AND/OR CHANGE OUR NEGATIVE AIR
PRE-FILTER.
SUPPLY DUCTS EITHER
KEEP RUNNING OR
COVER WHEN
RUNNING TO KEEP
DUST OUT.
A
V
O
TAPE ALL SERVICES TO
PROTECT AGAINST
CONTAMINATION
E
FIRE EXTINGUISHER ON PORTABLE FLOOR
BRACKET (SHALL REQUIRE MORE THAN
ONE.)
PHASE 1
PHASE 2
INFECTION CONTROL / DUST CONTROL
PARTITION / BARRIER
ICRA SYMBOL LEGEND
INFECTION CONTROL/DUST
CONTROL EGRESS DOOR AND
"STICKY MAT" FLOOR PADS
PATH OF DEMOLITION/TRASH REMOVAL TRAVEL
CONSTRUCTION LIMIT LINE
• IMPLEMENT INFECTION CONTROL RISK ASSESSMENT (ICRA)
PROCEDURES AS PER THE MARION VA MEDICAL CENTER ICRA PLAN
AND AS DIRECTED BY THE CONTRACTING OFFICER REPRESENTATIVE
(COR)
• CONTRACTORS SHALL COORDINATE WITH COR FOR ALL
CONSTRUCTION DUST/DEBRIS REQUIREMENTS & MEASURES DURING
DEMOLITION /CONSTRUCTION.
• COORDINATE ALL DEMOLITION/ CONSTRUCTION DEBRIS PATH OF
TRAVEL AND INTERIM LIFE SAFETY MEASURES (ILSM) WITH THE COR.
ALL INTERIOR DOORS THAT LEAD TO THE CONSTRUCTION SITE SHALL
BE POSTED AS PER THE ISLM PLAN.
• THE CONTRACTOR SHALL CONTINUE ALL OPERATIONS (INCLUDING
STORAGE OF MATERIALS) ON GOVERNMENT PREMISES TO AREAS
AUTHORIZED OR APPROVED BY THE COR.
INFECTION CONTROL RISK ASSESSMENT NOTES
0 8'-0" 16'-0" 32'-0"
PLAN
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
C
Phase
ARCHITECT OF RECORD STAMPENGINEERS OF RECORD
321 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
A/E:
C on e ei gh th in ch o ne fo ot
B
A
C
D
E
F th re e in ch es o ne fo ot on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot th re e qu ar te rs in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot on e ha lf in ch o ne fo ot
6"
6"
6"
6"
C :\r vt \2
6\
8 3
-A
-C E
N T
R A
L_ V
I S N
-1
-4 th F lo or
_ M
IN
E
LS
O N
.r vt
C :\r vt \2
6\
8 3
-A
-C E
N T
R A
L_ V
I S N
-1
-4 th F lo or
_ M
IN
E
LS
O N
.r vt
/1
/2
:2
:0
P
M
GI-204
FOURTH FLOOR - INFECTION
CONTROL PLAN
610-17-101
03/19/18 ED MN
ISSUED FOR
CONSTRUCTION
Project Director
1700 E. 38TH STREET MARION, IN 46953
VISN 11 MARION B-138: 4TH FLOOR
CONSTRUCTION
SPRINKLERED
HDR ARCHITECTURE, INC.
600 HENNEPIN AVE SUITE 260
MINNEAPOLIS, MN 55403
612.524.6000
TERRY LITTELL SR., RA,
LEED AP
KORDA, INC.
1650 WATERMARK DRIVE, SUITE 200
COLUMBUS, OH 43215
614.487.1650
STAN KMONK
METRIC ENVIRONMENTAL
6971 HILLSDALE COURT
INDIANAPOLIS, IN 46250
1" = 10'-0" D1
FOURTH FLOOR PHASING DIAGRAM WITH ILSM & ICRA
1/2" = 1'-0" E3
CROSS SECTION AT TEMPORARY WALL
1/2" = 1'-0" F1
TYPICAL CONSTRUCTION LAYOUT- CLASS IV
A. THE ONE HOUR FIRE RATED CONSTRUCTION BARRIERS SHALL
BE CONSTRUCTED PRIOR TO BEGINNING OTHER WORK.
B. FIRE PROTECTION SYSTEMS SHALL REMAIN FUNCTIONAL FOR
OCCUPIED AREAS ON THE FLOOR.
C. PROVIDE FIRE EXTINGUISHERS IN CONSTRUCTION AREAS;
REVIEW WITH COR AND VA SAFETY…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.