36C25018B0816-0003002.doc

DOC document 38 KB Posted

Attached to
Reno 4th Fl Bldg 138 610-17-101 Federal contract opportunity
Solicitation number
36C25018B0816
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10

About this file

36C25018B0816 0003 RFI#2 - 36C25018B0816.doc

View the file

Other files for this federal contract opportunity

Other files attached to Reno 4th Fl Bldg 138 610-17-101, newest first.
File Type Posted
36C25018B0816-0005000.docx DOCX document
36C25018B0816-0004000.docx DOCX document
36C25018B0816-0003012.doc DOC document
36C25018B0816-0003004.pdf PDF
36C25018B0816-0003009.pdf PDF
36C25018B0816-0003001.pdf PDF
36C25018B0816-0003005.doc DOC document
36C25018B0816-0003013.doc DOC document
36C25018B0816-0003003.doc DOC document
36C25018B0816-0003007.doc DOC document
36C25018B0816-0003010.doc DOC document
36C25018B0816-0003006.doc DOC document
36C25018B0816-0003014.pdf PDF
36C25018B0816-0003000.docx DOCX document
36C25018B0816-0003008.pdf PDF
36C25018B0816-0003011.pdf PDF
36C25018B0816-0002003.pdf PDF
36C25018B0816-0002002.pdf PDF
36C25018B0816-0002001.docx DOCX document
36C25018B0816-0002000.docx DOCX document
36C25018B0816-0001004.pdf PDF
36C25018B0816-0001003.docx DOCX document
36C25018B0816-0001000.docx DOCX document
36C25018B0816-0001002.pdf PDF
36C25018B0816-0001001.pdf PDF
36C25018B0816-001.docx DOCX document
36C25018B0816-003.pdf PDF
36C25018B0816-005.pdf PDF
36C25018B0816-010.docx DOCX document
36C25018B0816-007.pdf PDF
36C25018B0816-006.pdf PDF
36C25018B0816-011.doc DOC document
36C25018B0816-002.pdf PDF
36C25018B0816-009.pdf PDF
36C25018B0816-004.pdf PDF
36C25018B0816-008.pdf PDF
36C25018B0816-000.docx DOCX document
Show all 37

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REQUEST FOR INFORMATION (RFI)

36C25018B0816

PROJECT NUMBER:
610-17-101
Please ensure that before submitting questions or requests for clarification that you thoroughly read the solicitation, specifications, drawings and other pertinent documents. When submitting questions on this project the Government requires contractors to specifically identify the specification and/or solicitation section(s) or drawing number(s) in reference to the question or request for clarification submitted. No question or request for clarification will be answered by the Government unless the above requirements are met. Failure to comply may prevent the Government from responding in a timely manner.
PROJECT TITLE:
Renovate 4th Floor, Bldg. 138
PROJECT LOCATION:
Department of Veterans Affairs

VA Northern Indiana HCS 1700 E. 38th Street Marion, IN 46953

SUBMITTED BY:
IMS Contracting – Dale LaMarche
CITY/STATE:
Escanaba, MI.
PHONE:
906-789-9021 Ext. 26

TO:

Felecia Beamen, Contracting Officer Department of Veterans Affairs Network 10 Contracting Office

8888 Keystone Crossing, Suite 1100

Indianapolis, IN 46240 Felecia.Beamen@va.gov

RFI NO.: 001
DATE: 09/11/2018
SPEC/DWG. REFERENCE(s):

Audiometric booth questions

REPLY NEEDED BY:

INFORMATION NEEDED:

1. Ref drawing A104.1-Will the audiometric suites 422B, 423B and 424B be installed in depressed slabs/pits? Not using the floors and making them “low profile” may affect the lower level frequencies for testing.

2. Ref spec 13 20 00- Will the VA require: RF (EMF) Noise reduction usually level 1 60 Hz noise reduction?

3. Ref spec 13 20 00- Confirm that the panels must have a 60 minute burn time?

4. Ref spec 13 20 00- Standard height of the inside of these suites is 6’6” does the VA require this to be taller (current ADA compliance?) as the door height opening is 6’ 1 3/4”!

5. Ref drawing. A-104.1-Do you have the actual dimensions of the required audiometric suites or the rooms in which they will be installed.

6. Ref drawing A-104.1-Confirm that these suites will be double walled exam rooms with single walled control rooms!

7. Does the facility have elevators large enough to accommodate 12’ long panels?

8. Ref spec 13 20 00-Confirm how many dual outlets are required in each room pf the suites (standard offered by manufacturers 3), will they require the following rough in services for data, fire strobe lights, telephone or any special requirements to run cables?

REPLY:

Audiometric booths will be purchased and installed by the VA. This will be modified in the Equipment Schedules. The GC is only responsible to be sure adequate utility supplies are brought to the area as shown in the drawings.

REPLY FROM:

DATE:

ATTACHMENTS:

COPY TO: