27-0001 Attachment S- Davison Roof Asbestos Bulk Sampling Report.pdf

PDF 1 MB Posted

Attached to
27-0001 Facility Master Plan Series 6 Roof Replacement for
Solicitation number
RFP DET 260000002534 1
Issued by
Wayne County, Detroit City, Michigan

About this file

Asbestos Bulk Sampling Report Summary

This is an asbestos bulk sampling report prepared by Atlas Technical Consultants for the Detroit Public Schools Community District (DPSCD) regarding roofing materials at Davison Elementary School located at 2800 E. Davison Street, Detroit, Michigan. The sampling was conducted on July 17, 2026, by a Michigan-certified asbestos inspector to identify suspect asbestos-containing building materials (ACBMs) prior to planned renovation and/or demolition activities. A total of eighteen (18) bulk samples representing 33 sample layers were collected from the roof and submitted for Polarized Light Microscopy (PLM) analysis in accordance with OSHA Asbestos Construction Industry Standard (29 CFR 1926.1101) and the Asbestos Hazard and Emergency Response Act of 1987 (AHERA). The samples included roofing materials, roof flashing, and exterior caulk from parapet walls and seams.

Laboratory analytical results provided by Environmental Testing Laboratories, Inc. indicated that none of the roofing materials sampled contained asbestos. All 33 sample layers analyzed yielded "None Detected" (ND) results for asbestos content, with the report clarifying that materials are only considered Asbestos Containing Material (ACM) if they contain greater than 1 percent asbestos. The report includes standard limitations noting that inaccessible areas behind walls, columns, beneath flooring, above ceilings, and underground locations may contain ACBMs not identified during this survey, and recommends that any materials discovered during renovation activities not listed in the report should be assumed asbestos-containing until sampled and analyzed by a licensed building inspector.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

46555 Humboldt Dr. Ste. 100 Novi, MI 48377

(248) 669-5140 | oneatlas.com

July 27, 2026

Mr. Michael Flowers Detroit Public Schools Community District Office of Environmental Health & Safety 1601 Farnsworth Detroit, Michigan 48207

SUBJECT: Roofing Materials Asbestos Bulk Sampling Report

Davison Elementary School 2800 E. Davison Street Detroit, MI 48212 Project #: 188BS26361

Dear Mr. Flowers:

Atlas Technical Consultants (Atlas) was retained by the Detroit Public Schools Community District (DPSCD) to perform asbestos sampling at the above referenced site. The purpose of this sampling was to identify and collect samples of suspect asbestos containing building materials (ACBM’s) prior to renovation and/or demolition activities.

The limited asbestos sampling was conducted on July 17, 2026, by Atlas Industrial Hygienist, Ms. Kari Lamprich, State of Michigan certified asbestos inspector. The sampling was conducted in accordance with sampling criteria specified in the Occupational Safety and Health Administration’s (OSHA) Asbestos Construction Industry Standard (29 CFR 1926.1101), and the Asbestos Hazard and Emergency Response Act of 1987 (AHERA).

ASBESTOS BULK SAMPLING

Atlas arrived at the above-mentioned location at the request of DPSCD to sample suspect asbestos containing roofing materials. A total of eighteen (18) bulk samples were collected and submitted for analysis by Polarized Light Microscopy (PLM). Of the eighteen (18) samples submitted, 33 sample layers were analyzed for asbestos content. The description, location and type of material sampled can be found in Table 1 along with the results of analysis. The laboratory analytical report and chain-of-custody for the samples collected are provided in Attachment A. Laboratory results indicated that none of the roofing materials sampled contained asbestos.

LIMITATIONS

This report is prepared for the express use and benefit of DPSCD, its agents and employees. The information in this report or portions thereof may be required to be included in notifications to employees, contractors or other visitors to the buildings. This report is not intended to be used by the owner or its agents as a specification or work plan for any of the work suggested or recommended in the report. This report is based upon conditions observed at the property and information made available to the surveyor on the above-mentioned date. This report does not intend to identify all hazards, nor to indicate that other hazards do not exist on the premises. Atlas made their best effort to determine the location of inaccessible ACBM’s. Atlas shall not be responsible for identifying all ACBM’s located behind walls and/or columns, beneath flooring, above solid ceilings, underground or any other inaccessible areas. If material is found during renovations that are not listed in this asbestos report the material should be assumed as asbestos containing until it can be sampled by a licensed building inspector and analyzed at a laboratory.

Atlas is pleased to be of continued service to DPSCD, and we look forward to continuing working with you in the future. If you have any questions or comments regarding the information in this report, please contact us at 249-669-5140.

Sincerely, Atlas Technical Consultants

Kari Lamprich State of Michigan Asbestos Inspector Atlas Technical Consultants LLC

Jennifer Fashbaugh Department Manager Atlas Technical Consultants LLC

Attachment A Laboratory Analytical Report and Chain of Custody Form Attachment B Photo Log

Table 1 Davison Elementary School - Roof

2800 E. Davison Street Detroit, Michigan 48212

July 17, 2026

Description Location Friable Yes/No (1)

Percent Asbestos Type (2)

Sample ID No.

Roofing Material (tar over fiberglass and vapor barrier) Roof No ND 1-RM-A,B,C

Roof Flashing (black painted silver) Roof No ND 2-FL-A,B,C

Roofing Material (tar over fiberglass) Roof No ND 3-RM-A,B,C

Roof Flashing (dark gray) Roof No ND 4-FL-A,B,C

Exterior Caulk (gray) Roof (parapet walls/seams) No ND 5-EC-A,B,C

Roofing Material (asphalt roofing w/fiberglass) Roof No ND 6-RM-A,B,C

Table 1 Key:

PJ=Pipe joint/fitting ND=No Asbestos Detected SF=Square Feet CP=Ceiling Panel NA=Not Analyzed LF=Linear Feet FT= Floor Tile CT=Ceiling Tile DI=Duct Insulation

Notes:

1. Indicates whether a material is friable or non-friable. A friable material is that which can be crumbled, pulverized, or reduced to powder by hand pressure when dry. Friable ACM presents a higher hazard potential than non-friable materials.

2. Six types of asbestos minerals are known to exist: (A) Amosite, (B) Anthophyllite, (C) Actinolite, (D) Chrysotile, (E) Crocidolite, (F) Tremolite. All detected concentrations are approximate.

Attachment A

Laboratory Analytical Report and Chain of Custody Form

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive Romulus, Michigan 48174

(734) 955-6600

Fax: (734) 955-6604

To:

Attention:

Atlas - Novi

46555 Humboldt Dr. Suite 100

Novi, Michigan 48377

Project Location:

DPSCD - Davidson

2800 E Davidson Street, Detroit, MI 48212

Client Project: 188BS26361

292817ETL Job:

Jennifer Fashbaugh

Report Issued: 07/21/2026

Lab Sample Number Client Sample Number Sample Type CompletedSampled Analyst

1910816 Asbestos1-RM-A 07/21/2026 Ben Jones07/17/2026

1910817 Asbestos1-RM-B 07/21/2026 Ben Jones07/17/2026

1910818 Asbestos1-RM-C 07/21/2026 Ben Jones07/17/2026

1910819 Asbestos2-FL-A 07/21/2026 Ben Jones07/17/2026

1910820 Asbestos2-FL-B 07/21/2026 Ben Jones07/17/2026

1910821 Asbestos2-FL-C 07/21/2026 Ben Jones07/17/2026

1910822 Asbestos3-RM-A 07/21/2026 Ben Jones07/17/2026

1910823 Asbestos3-RM-B 07/21/2026 Ben Jones07/17/2026

1910824 Asbestos3-RM-C 07/21/2026 Ben Jones07/17/2026

1910825 Asbestos4-FL-A 07/21/2026 Ben Jones07/17/2026

1910826 Asbestos4-FL-B 07/21/2026 Ben Jones07/17/2026

1910827 Asbestos4-FL-C 07/21/2026 Ben Jones07/17/2026

1910828 Asbestos5-EC-A 07/21/2026 Ben Jones07/17/2026

1910829 Asbestos5-EC-B 07/21/2026 Ben Jones07/17/2026

1910830 Asbestos5-EC-C 07/21/2026 Ben Jones07/17/2026

1910831 Asbestos6-RM-A 07/21/2026 Ben Jones07/17/2026

This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this information in error, please notify ETL immediately. Thank you.

Lab Sample Number Client Sample Number Sample Type CompletedSampled Analyst

1910832 Asbestos6-RM-B 07/21/2026 Ben Jones07/17/2026

1910833 Asbestos6-RM-C 07/21/2026 Ben Jones07/17/2026

Reviewed by:

Summary

Sample Layer MasticMethod

PLM 33Dawson Bradley

This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this information in error, please notify ETL immediately. Thank you.

Certificate of Analysis

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Novi,Michigan 48377

Atlas - Novi

46555 Humboldt Dr. Suite 100

DPSCD - Davidson

2800 E Davidson Street, Detroit, MI 48212

ETL Job :

Client Project :

292817

188BS26361

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

07/17/2026

07/20/2026

Date Collected :

Date Received :

PLM None Detected 1910816

1-RM-A

PLM 100% OtherPLM Trace CelluloseBlackTar

Non-Fibrous

Homogenous Layer-1 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910816

1-RM-A

PLM 10% OtherPLM 90% FiberglassYellowFiberglass

Fibrous

Homogenous Layer-2 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910816

1-RM-A

PLM 8% OtherPLM 92% CelluloseYellowVapor Barrier

Fibrous

Homogenous Layer-3 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910817

1-RM-B

PLM 100% OtherPLM Trace CelluloseBlackTar

Non-Fibrous

Homogenous Layer-1 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910817

1-RM-B

PLM 10% OtherPLM 90% FiberglassYellowFiberglass

Fibrous

Homogenous Layer-2 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910817

1-RM-B

PLM 8% OtherPLM 92% CelluloseYellowVapor Barrier

Fibrous

Homogenous Layer-3 Analyst: Ben Jones

Date Analyzed : 07/21/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Novi,Michigan 48377

Atlas - Novi

46555 Humboldt Dr. Suite 100

DPSCD - Davidson

2800 E Davidson Street, Detroit, MI 48212

ETL Job :

Client Project :

292817

188BS26361

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

07/17/2026

07/20/2026

Date Collected :

Date Received :

PLM None Detected 1910818

1-RM-C

PLM 100% OtherPLM Trace CelluloseBlackTar

Non-Fibrous

Homogenous Layer-1 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910818

1-RM-C

PLM 10% OtherPLM 90% FiberglassYellowFiberglass

Fibrous

Homogenous Layer-2 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910818

1-RM-C

PLM 8% OtherPLM 92% CelluloseYellowVapor Barrier

Fibrous

Homogenous Layer-3 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910819

2-FL-A

PLM 92% OtherPLM 8% CelluloseBlack / SilverRoof Flashing

Non-Fibrous

Homogenous Layer-1 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910820

2-FL-B

PLM 92% OtherPLM 8% CelluloseBlack / SilverRoof Flashing

Non-Fibrous

Homogenous Layer-1 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910821

2-FL-C

PLM 92% OtherPLM 8% CelluloseBlack / SilverRoof Flashing

Non-Fibrous

Homogenous Layer-1 Analyst: Ben Jones

Date Analyzed : 07/21/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Novi,Michigan 48377

Atlas - Novi

46555 Humboldt Dr. Suite 100

DPSCD - Davidson

2800 E Davidson Street, Detroit, MI 48212

ETL Job :

Client Project :

292817

188BS26361

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

07/17/2026

07/20/2026

Date Collected :

Date Received :

PLM None Detected 1910822

3-RM-A

PLM 100% OtherPLM Trace CelluloseBlackTar

Non-Fibrous

Homogenous Layer-1 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910822

3-RM-A

PLM 7% OtherPLM 93% FiberglassBrownFiberglass

Fibrous

Homogenous Layer-2 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910823

3-RM-B

PLM 100% OtherPLM Trace CelluloseBlackTar

Non-Fibrous

Homogenous Layer-1 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910823

3-RM-B

PLM 7% OtherPLM 93% FiberglassBrownFiberglass

Fibrous

Homogenous Layer-2 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910824

3-RM-C

PLM 100% OtherPLM Trace CelluloseBlackTar

Non-Fibrous

Homogenous Layer-1 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910824

3-RM-C

PLM 7% OtherPLM 93% FiberglassBrownFiberglass

Fibrous

Homogenous Layer-2 Analyst: Ben Jones

Date Analyzed : 07/21/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Novi,Michigan 48377

Atlas - Novi

46555 Humboldt Dr. Suite 100

DPSCD - Davidson

2800 E Davidson Street, Detroit, MI 48212

ETL Job :

Client Project :

292817

188BS26361

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

07/17/2026

07/20/2026

Date Collected :

Date Received :

PLM None Detected 1910825

4-FL-A

PLM 95% OtherPLM 5% CelluloseDark GrayFlashing

Non-Fibrous

Homogenous Layer-1 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910826

4-FL-B

PLM 95% OtherPLM 5% CelluloseDark GrayFlashing

Non-Fibrous

Homogenous Layer-1 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910827

4-FL-C

PLM 95% OtherPLM 5% CelluloseDark GrayFlashing

Non-Fibrous

Homogenous Layer-1 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910828

5-EC-A

PLM 100% OtherPLM Trace CelluloseGrayCaulking

Non-Fibrous

Homogenous Layer-1 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910829

5-EC-B

PLM 100% OtherPLM Trace CelluloseGrayCaulking

Non-Fibrous

Homogenous Layer-1 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910830

5-EC-C

PLM 100% OtherPLM Trace CelluloseGrayCaulking

Non-Fibrous

Homogenous Layer-1 Analyst: Ben Jones

Date Analyzed : 07/21/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Novi,Michigan 48377

Atlas - Novi

46555 Humboldt Dr. Suite 100

DPSCD - Davidson

2800 E Davidson Street, Detroit, MI 48212

ETL Job :

Client Project :

292817

188BS26361

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

07/17/2026

07/20/2026

Date Collected :

Date Received :

PLM None Detected 1910831

6-RM-A

PLM 100% OtherPLM Trace CelluloseBlackAsphalt Roofing

Non-Fibrous

Homogenous Layer-1 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910831

6-RM-A

PLM 9% OtherPLM 91% FiberglassYellowFiberglass

Fibrous

Homogenous Layer-2 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910831

6-RM-A

PLM 100% OtherPLM Trace CelluloseBlackAsphaltic Material

Non-Fibrous

Homogenous Layer-3 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910832

6-RM-B

PLM 100% OtherPLM Trace CelluloseBlackAsphalt Roofing

Non-Fibrous

Homogenous Layer-1 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910832

6-RM-B

PLM 9% OtherPLM 91% FiberglassYellowFiberglass

Fibrous

Homogenous Layer-2 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910832

6-RM-B

PLM 100% OtherPLM Trace CelluloseBlackAsphaltic Material

Non-Fibrous

Homogenous Layer-3 Analyst: Ben Jones

Date Analyzed : 07/21/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Novi,Michigan 48377

Atlas - Novi

46555 Humboldt Dr. Suite 100

DPSCD - Davidson

2800 E Davidson Street, Detroit, MI 48212

ETL Job :

Client Project :

292817

188BS26361

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

07/17/2026

07/20/2026

Date Collected :

Date Received :

PLM None Detected 1910833

6-RM-C

PLM 100% OtherPLM Trace CelluloseBlackAsphalt Roofing

Non-Fibrous

Homogenous Layer-1 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910833

6-RM-C

PLM 9% OtherPLM 91% FiberglassYellowFiberglass

Fibrous

Homogenous Layer-2 Analyst: Ben Jones

Date Analyzed : 07/21/2026

PLM None Detected 1910833

6-RM-C

PLM 100% OtherPLM Trace CelluloseBlackAsphaltic Material

Non-Fibrous

Homogenous Layer-3 Analyst: Ben Jones

Date Analyzed : 07/21/2026

Lab Supervisor/Other Signatory

Ben Jones

Analyst:

400 Point Count Results by EPA 600/R-93/116 PLM (denoted by "PC")

Item 198.1: PLM Methods for Identifying and Quantitating Asbestos in Bulk Samples

Item 198.6: PLM Methods for Identifying and Quantitating Asbestos in Non-Friable Organically Bound Bulk Samples

EPA 600/R-93/116: Method for Determination of Asbestos in Bulk Building Materials

EPA 600/M4-82-020: Interim Method for Determination of Asbestos in Bulk Insulation Samples

A % Asbestos result of "Trace" indicates that the analyzed material was found to contain less than 1% asbestos and would not be considered an Asbestos Containing Material (ACM).

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Attachment B

Photo Log

DPSCD Davison Photograph Log 2800 E Davidson Street

Detroit, Michigan 48212

188BS26361

Photograph #1

Homogenous Material Description

HA-1: Tar over fiberglass and vapor barrier

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

Additional Notes

Photograph #2

HA-2: Black painted silver roof flashing

Asbestos Present (Yes/No/Assumed)

Photograph #3

HA-3: Tar over fiberglass

Asbestos Present (Yes/No/Assumed)

DPSCD Davison Photograph Log 2800 E Davidson Street

Detroit, Michigan 48212

188BS26361

Photograph #4

HA-4: Dark gray flashing

Asbestos Present (Yes/No/Assumed)

Photograph #5

HA-5: Gray caulking on parapet walls and seams

Asbestos Present (Yes/No/Assumed)

Photograph #6

Not Pictured

HA-6: Asphalt roofing with fiberglass

Asbestos Present (Yes/No/Assumed)

SUBJECT: Roofing Materials Asbestos Bulk Sampling Report

File details come from the government source that posted it. Updated .