This is a Limited Asbestos Containing Material (ACM) Bulk Sampling Report prepared by Atlas Technical Consultants for the Detroit Public Schools Community District (DPSCD) regarding Burton International Academy located at 2001 Martin Luther King Jr. Boulevard in Detroit, Michigan. The sampling was conducted on March 9, 2026, by certified asbestos inspector Kari Lamprich in accordance with OSHA Asbestos Construction Industry Standards and the Asbestos Hazard and Emergency Response Act (AHERA). A total of twenty-one bulk samples were collected from the roof and submitted for laboratory analysis, with thirty sample layers analyzed using Polarized Light Microscopy (PLM) by Environmental Testing Laboratories, Inc. The analytical work was completed on March 13, 2026, with results received by Atlas on the same date.

All thirty sample layers analyzed tested negative for asbestos content (No Detected/ND), indicating that the roofing materials, flashing, and caulking materials sampled do not contain asbestos above detectable levels. The sampled materials included roofing material with black tar and perlite, roofing material with black tar, perlite and vapor barrier, silver flashing, beige caulk, gray caulk, black tar penetration roofing, and gray expansion caulk—all classified as non-friable materials. The report notes that all materials tested were non-friable and that no asbestos-containing materials were identified. Atlas specified that if additional materials are discovered during roof replacement activities that were not included in this survey, such materials should be assumed to contain asbestos until sampled and analyzed by a licensed building inspector and laboratory.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LIMITED ASBESTOS CONTAINING MATERIAL BULK SAMPLING REPORT

BURTON INTERNATIONAL ACADEMY

2001 MARTIN LUTHER KING, JR. BOULEVARD

DETROIT, MI 48208

PREPARED FOR:

DETROIT PUBLIC SCHOOLS COMMUNITY DISTRICT

PREPARED BY:

Atlas Technical Consultants 46555 Humboldt Drive, Ste. 100 Novi, MI 48377 July 1, 2026

July 1, 2026

Mr. Michael Flowers Detroit Public Schools Community District Office Of Environmental Health & Safety 1601 Farnsworth Street Detroit, Michigan 48207

Subject: Limited Asbestos Containing Material Bulk Sampling Report Burton International Academy 2001 Martin Luther King Jr. Boulevard Detroit, Michigan 48208

Project #: 188BS26134

Dear Mr. Flowers, Atlas Technical Consultants (Atlas) was retained by the Detroit Public Schools Community District (DPSCD) to perform asbestos sampling at the above referenced site. The purpose of this sampling was to identify and collect samples of suspect asbestos containing building materials (ACBM’s) prior to renovation and/or demolition activities.

The limited asbestos sampling was conducted on March 9, 2026, by Atlas Industrial Hygienist, Ms. Kari Lamprich, State of Michigan certified asbestos inspector. The sampling was conducted in accordance with sampling criteria specified in the Occupational Safety and Health Administration’s (OSHA) Asbestos Construction Industry Standard (29 CFR 1926.1101), and the Asbestos Hazard and Emergency Response Act of 1987 (AHERA).

SUMMARY OF ACM SURVEY ACTIVITIES AND SURVEY FINDINGS

Atlas arrived at the above-mentioned location at the request of DPSCD to sample suspect asbestos containing building materials on the roof. A total of twenty-one (21) bulk samples were collected and submitted for analysis by Polarized Light Microscopy (PLM). Of the twenty-one (21) samples submitted, thirty (30) sample layers were analyzed for asbestos content.

The description, location and type of material sampled can be found in Table 1 along with the results of analysis. Analytical data sheets and chain-of-custody information for the collected samples are provided in Attachment A.

LIMITATIONS

This report is prepared for the express use and benefit of DPSCD, its agents and employees. The information in this report or portions thereof may be required to be included in notifications to employees, contractors or other visitors to the buildings. This report is not intended to be used by the owner or its agents as a specification or work plan for any of the work suggested or recommended in the report. This report is based upon conditions observed at the property and information made available to the surveyor on the above-mentioned date. This report does not intend to identify all hazards, nor to indicate that other hazards do not exist at the premises. Atlas made their best effort to determine the location of inaccessible ACBM’s. Atlas shall not be responsible for identifying all ACBM’s located behind walls and/or columns, beneath flooring, above solid ceilings, underground or any other inaccessible areas. If material is found during the course of renovations that is not listed in this asbestos report the material should be assumed as asbestos containing until it can be sampled by a licensed building inspector and analyzed at a laboratory.

Atlas is pleased to be of continued service to DPSCD and we look forward to continue working with you in the future. If you have any questions or comments regarding the information in this report please contact us at 249-669-5140.

Respectfully submitted, Atlas Technical Consultants LLC

Kari Lamprich Asbestos Inspector

Jennifer Fashbaugh Project Manager

Attachments Attachment A - Chain of Custody Forms and Analytical Data Sheets

Table 1 Burton International Academy

2001 Martin Luther King Jr. Boulevard Detroit, Michigan 48208

Description Location Friable Yes/No (1)

Percent Asbestos Type (2)

Quantity

(LF/SF)

Sample ID No.

Roofing Material (black tar & perlite) Roof No ND UNQ 1-RM-A,B,C

Roofing Material (black tar, perlite, & vapor barrier) Roof No ND UNQ 2-RM-A,B,C

Roofing Material (silver flashing) Roof No ND UNQ 3-RM-A,B,C

Beige Caulk Roof Perimeter No ND UNQ 4-EC-A,B,C

Gray Caulk Roof No ND UNQ 5-EC-A,B,C Roofing Material (black tar penetration) Roof No ND UNQ 6-RM-A,B,C

Gray Expansion Caulk Roof No ND UNQ 7-EC-A,B,C

Table 1 Key:

PJ=Pipe joint/fitting ND=No Asbestos Detected SF=Square Feet UNQ=Unquantified CP=Ceiling Panel NA=Not Analyzed LF=Linear Feet FT= Floor Tile CT=Ceiling Tile DI=Duct Insulation

Notes:

1. Indicates whether a material is friable or non-friable. A friable material is that which can be crumbled, pulverized, or reduced to powder by hand pressure when dry. Friable ACM presents a higher hazard potential than non-friable materials.

2. Six types of asbestos minerals are known to exist: (A) Amosite, (B) Anthophyllite, (C) Actinolite, (D) Chrysotile, (E) Crocidolite, (F) Tremolite. All detected concentrations are approximate.

ATTACHMENT A

CHAIN OF CUSTODY FORMS AND ANALYTICAL DATA SHEETS

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive Romulus, Michigan 48174

(734) 955-6600

Fax: (734) 955-6604

To:

Attention:

Atlas - Novi

46555 Humboldt Dr. Suite 100

Novi, Michigan 48377

Project Location:

DPSCD - Roof Sampling - Burton International Academy

2001 Martin Luther King Jr Blvd, Detroit, MI 48208

Client Project: 188BS26130

289064ETL Job:

Jennifer Fashbaugh

Report Issued: 03/13/2026

Lab Sample Number Client Sample Number Sample Type CompletedSampled Analyst

1871215 Asbestos1-RM-A 03/13/2026 OJ Ivey03/09/2026

1871216 Asbestos1-RM-B 03/13/2026 OJ Ivey03/09/2026

1871217 Asbestos1-RM-C 03/13/2026 OJ Ivey03/09/2026

1871218 Asbestos2-RM-A 03/13/2026 OJ Ivey03/09/2026

1871219 Asbestos2-RM-B 03/13/2026 OJ Ivey03/09/2026

1871220 Asbestos2-RM-C 03/13/2026 OJ Ivey03/09/2026

1871221 Asbestos3-RM-A 03/13/2026 OJ Ivey03/09/2026

1871222 Asbestos3-RM-B 03/13/2026 OJ Ivey03/09/2026

1871223 Asbestos3-RM-C 03/13/2026 OJ Ivey03/09/2026

1871224 Asbestos4-EC-A 03/13/2026 OJ Ivey03/09/2026

1871225 Asbestos4-EC-B 03/13/2026 OJ Ivey03/09/2026

1871226 Asbestos4-EC-C 03/13/2026 OJ Ivey03/09/2026

1871227 Asbestos5-EC-A 03/13/2026 OJ Ivey03/09/2026

1871228 Asbestos5-EC-B 03/13/2026 OJ Ivey03/09/2026

1871229 Asbestos5-EC-C 03/13/2026 OJ Ivey03/09/2026

1871230 Asbestos6-RM-A 03/13/2026 OJ Ivey03/09/2026

This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this information in error, please notify ETL immediately. Thank you.

Lab Sample Number Client Sample Number Sample Type CompletedSampled Analyst

1871231 Asbestos6-RM-B 03/13/2026 OJ Ivey03/09/2026

1871232 Asbestos6-RM-C 03/13/2026 OJ Ivey03/09/2026

1871233 Asbestos7-EC-A 03/13/2026 OJ Ivey03/09/2026

1871234 Asbestos7-EC-B 03/13/2026 OJ Ivey03/09/2026

1871235 Asbestos7-EC-C 03/13/2026 OJ Ivey03/09/2026

Reviewed by:

Summary

Sample Layer MasticMethod

PLM 30Dawson Bradley

This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this information in error, please notify ETL immediately. Thank you.

Certificate of Analysis

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Novi,Michigan 48377

Atlas - Novi

46555 Humboldt Dr. Suite 100

DPSCD - Roof Sampling - Burton International Academy

2001 Martin Luther King Jr Blvd, Detroit, MI 48208

ETL Job :

Client Project :

289064

188BS26130

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

03/09/2026

03/13/2026

Date Collected :

Date Received :

PLM None Detected 1871215

1-RM-A

PLM 94% OtherPLM 6% CelluloseBlackTar

Non-Fibrous

Homogenous Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871215

1-RM-A

PLM 73% OtherPLM 27% CelluloseGreyPerlite

Fibrous

Homogenous Layer-2 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871216

1-RM-B

PLM 98% OtherPLM 2% CelluloseBlackTar

Non-Fibrous

Homogenous Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871216

1-RM-B

PLM 55% OtherPLM 45% CelluloseGreyPerlite

Fibrous

Homogenous Layer-2 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871217

1-RM-C

PLM 94% OtherPLM 6% CelluloseBlackTar

Non-Fibrous

Homogenous Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871217

1-RM-C

PLM 60% OtherPLM 40% CelluloseGreyPerlite

Fibrous

Homogenous Layer-2 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Novi,Michigan 48377

Atlas - Novi

46555 Humboldt Dr. Suite 100

DPSCD - Roof Sampling - Burton International Academy

2001 Martin Luther King Jr Blvd, Detroit, MI 48208

ETL Job :

Client Project :

289064

188BS26130

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

03/09/2026

03/13/2026

Date Collected :

Date Received :

PLM None Detected 1871218

2-RM-A

PLM 90% OtherPLM 10% CelluloseBlackTar

Non-Fibrous

Homogenous Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871218

2-RM-A

PLM 45% OtherPLM 55% CelluloseGreyPerlite

Fibrous

Homogenous Layer-2 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871218

2-RM-A

PLM 62% OtherPLM 38% CelluloseBlackVapor Barrier

Fibrous

Homogenous Layer-3 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871219

2-RM-B

PLM 93% OtherPLM 7% CelluloseBlackTar

Non-Fibrous

Homogenous Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871219

2-RM-B

PLM 75% OtherPLM 25% CelluloseGreyPerlite

Fibrous

Homogenous Layer-2 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871219

2-RM-B

PLM 50% OtherPLM 50% CelluloseBlackVapor Barrier

Fibrous

Homogenous Layer-3 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Novi,Michigan 48377

Atlas - Novi

46555 Humboldt Dr. Suite 100

DPSCD - Roof Sampling - Burton International Academy

2001 Martin Luther King Jr Blvd, Detroit, MI 48208

ETL Job :

Client Project :

289064

188BS26130

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

03/09/2026

03/13/2026

Date Collected :

Date Received :

PLM None Detected 1871220

2-RM-C

PLM 95% OtherPLM 5% CelluloseBlackTar

Non-Fibrous

Homogenous Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871220

2-RM-C

PLM 71% OtherPLM 29% CelluloseGreyPerlite

Fibrous

Homogenous Layer-2 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871220

2-RM-C

PLM 60% OtherPLM 40% CelluloseBlackVapor Barrier

Fibrous

Homogenous Layer-3 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871221

3-RM-A

PLM 96% OtherPLM 4% CelluloseSilver / BlackFlashing

Non-Fibrous

Homogenous Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871222

3-RM-B

PLM 97% OtherPLM 3% CelluloseSilver / BlackFlashing

Non-Fibrous

Homogenous Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871223

3-RM-C

PLM 94% OtherPLM 6% CelluloseSilver / BlackFlashing

Non-Fibrous

Homogenous Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Novi,Michigan 48377

Atlas - Novi

46555 Humboldt Dr. Suite 100

DPSCD - Roof Sampling - Burton International Academy

2001 Martin Luther King Jr Blvd, Detroit, MI 48208

ETL Job :

Client Project :

289064

188BS26130

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

03/09/2026

03/13/2026

Date Collected :

Date Received :

PLM None Detected 1871224

4-EC-A

PLM 96% OtherPLM 4% CelluloseBeigeCaulking

Non-Fibrous

Homogenous Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871225

4-EC-B

PLM 98% OtherPLM 2% CelluloseBeigeCaulking

Non-Fibrous

Homogenous Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871226

4-EC-C

PLM 95% OtherPLM 5% CelluloseBeigeCaulking

Non-Fibrous

Homogenous Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871227

5-EC-A

PLM 96% OtherPLM 4% CelluloseGreyCaulking

Non-Fibrous

Homogenous Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871228

5-EC-B

PLM 98% OtherPLM 2% CelluloseGreyCaulking

Non-Fibrous

Homogenous Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871229

5-EC-C

PLM 99% OtherPLM 1% CelluloseGreyCaulking

Non-Fibrous

Homogenous Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Novi,Michigan 48377

Atlas - Novi

46555 Humboldt Dr. Suite 100

DPSCD - Roof Sampling - Burton International Academy

2001 Martin Luther King Jr Blvd, Detroit, MI 48208

ETL Job :

Client Project :

289064

188BS26130

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

03/09/2026

03/13/2026

Date Collected :

Date Received :

PLM None Detected 1871230

6-RM-A

PLM 96% OtherPLM 4% CelluloseBlackTar

Non-Fibrous

Homogenous Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871231

6-RM-B

PLM 97% OtherPLM 3% CelluloseBlackTar

Non-Fibrous

Homogenous Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871232

6-RM-C

PLM 95% OtherPLM 5% CelluloseBlackTar

Non-Fibrous

Homogenous Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871233

7-EC-A

PLM 96% OtherPLM 4% CelluloseGreyExpansion Caulking

Non-Fibrous

Homogenous Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871234

7-EC-B

PLM 94% OtherPLM 6% CelluloseGreyExpansion Caulking

Non-Fibrous

Homogenous Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

PLM None Detected 1871235

7-EC-C

PLM 97% OtherPLM 3% CelluloseGreyExpansion Caulking

Non-Fibrous

Homogenous Layer-1 Analyst: OJ Ivey

Date Analyzed : 03/13/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Novi,Michigan 48377

Atlas - Novi

46555 Humboldt Dr. Suite 100

DPSCD - Roof Sampling - Burton International Academy

2001 Martin Luther King Jr Blvd, Detroit, MI 48208

ETL Job :

Client Project :

289064

188BS26130

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

03/09/2026

03/13/2026

Date Collected :

Date Received :

Lab Supervisor/Other Signatory

OJ Ivey

Analyst:

400 Point Count Results by EPA 600/R-93/116 PLM (denoted by "PC")

Item 198.1: PLM Methods for Identifying and Quantitating Asbestos in Bulk Samples

Item 198.6: PLM Methods for Identifying and Quantitating Asbestos in Non-Friable Organically Bound Bulk Samples

EPA 600/R-93/116: Method for Determination of Asbestos in Bulk Building Materials

EPA 600/M4-82-020: Interim Method for Determination of Asbestos in Bulk Insulation Samples

A % Asbestos result of "Trace" indicates that the analyzed material was found to contain less than 1% asbestos and would not be considered an Asbestos Containing Material (ACM).

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

File details come from the government source that posted it. Updated .