27-0001 Attachment C - Davison Drawings IFB.pdf

PDF 3 MB Posted

Attached to
27-0001 Facility Master Plan Series 6 Roof Replacement for
Solicitation number
RFP DET 260000002534 1
Issued by
Wayne County, Detroit City, Michigan

About this file

This document is a comprehensive set of construction drawings and specifications for the roof replacement project at Davison Elementary-Middle School in Detroit, Michigan, prepared for Detroit Public Schools by Testing Engineers & Consultants. The project encompasses roof replacement work across nine distinct roof areas (A through I) totaling approximately 32,719 square feet, including removal of existing built-up roofing systems down to structural decks, installation of new polyisocyanurate insulation layers ranging from 1 to 5 inches depending on area, placement of 1/2-inch high-density polyiso cover boards, and application of fully-adhered 60-mil EPDM roofing membranes with 6-inch seams. Roof Area H requires a complete asphalt shingle system, while other areas receive the EPDM system. The drawings detail extensive flashing requirements including curb flashings, roof hatch replacements, roof drain sumps, tubular penetration flashings, parapet wall treatments, and gutter edge details, along with specifications for wood blocking, sealant applications, and stone coping joint resealing. Acceptable EPDM manufacturers include Carlisle, Johns Manville, and Elevate (Firestone), with an alternate price option required for a 20-year "Total System Warranty."

The specifications require contractor verification of existing site conditions including building dimensions, roof area dimensions, drainage component locations, roof penetrations, existing roof system composition, and repair quantities prior to proposal submission. Contractors must comply with all applicable federal, state, and local codes and regulations and notify the owner of any conflicts between design specifications and manufacturer requirements or governing ordinances. The contractor is responsible for asbestos laboratory analysis per referenced sections, removal and disposal of non-friable asbestos if present, temporary displacement and reinstallation of rooftop equipment by appropriately licensed contractors, closure of abandoned mechanical, plumbing, and electrical openings, and implementation of debris containment measures. A tapered drainage sump system with minimum 1/4-inch per foot slope must be created at roof drain locations, existing curbs must be raised to achieve minimum 8-inch flashing heights, existing roof hatches must be replaced with new units featuring integrated safety bars and internal ladders, and existing stone coping joints require raking and resealing.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CLIENT

PROFESSIONAL

PROJECT

DESCRIPTIONDATE

ISSUE

Drawn By: PD

Checked By: SH

SHEET TITLE

File Name:

STAMP

SHEET 01 OF 05

TITLE SHEET

PROJECT LOCATION MAP

ROOF PLAN SYMBOL LEGEND:

ORD

INS

C

S SKYLIGHT CURB

CAPPED CURB

ROOF HATCH

ROOF CURB

SUPPORT CURBS

ROOF DRAIN

ROOF DRAIN WITH INSERT

OVERFLOW ROOF DRAIN

THROUGH-WALL SCUPPER

OVERFLOW ROOF SCUPPER

ORS

SANITARY VENT

TUBULAR PENETRATION

HOT STACK

PIPE CHASE BOX

PERIMETER OR CURBED EDGE

PARAPET WALL OR AREA DIVIDER

EXPANSION JOINT

GUTTER EDGE

PITCH PAN

ROOF-TO-WALL TRANSITION

AREA TRANSITION

SATELLITE DISH ON ROOF

WALKPADW

WALKWAY

SUPPLY OR CONDENSATE LINE

LADDER

SLOPE DIRECTION

RIDGE LINE

DUCT WORK

R RAISED EQUIPMENT

DOWNSPOUT SPLASHBLOCKS

SUMP AREA

DOWNSPOUTCHIMNEY

THROUGH-FASCIA SCUPPER

SCUPPER WITH CONDUCTOR BOX DETAIL NUMBER CALLOUT

SHEET NUMBER CALLOUT

SCOPE OF REPLACEMENT MAP

GENERAL NOTES:

1. DRAWINGS ARE PRODUCED AT ARCH D (24-INCH BY 36-INCH) SIZE.

PLEASE NOTE AND VERIFY THE SCALE INDICATED ON EACH DRAWING.

NOTE THAT ROOF PLANS AND OTHER PROJECT DRAWINGS PRODUCED

ON OTHER PAPER SIZES MAY NOT BE CORRECTLY SCALED.

2. ALL COMPONENTS SHOWN ON PROJECT DRAWINGS ARE NEW UNLESS

SPECIFICALLY INDICATED AS EXISTING.

3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY EXISTING

PROJECT SITE CONDITIONS. THESE CONDITIONS INCLUDE, BUT ARE NOT

LIMITED TO: BUILDING DIMENSIONS AND PROPOSED PROJECT STAGING

LOCATIONS, ROOF REPLACEMENT AREA DIMENSIONS, ROOF DRAINAGE

COMPONENT LOCATIONS, ROOF PENETRATION LOCATIONS, EXISTING

ROOF SYSTEM COMPONENT MAKE-UP AND THICKNESS, AND PROJECT

REPAIR QUANTITIES (IF APPLICABLE). THE CONTRACTOR SHALL VISIT

AND BECOME FAMILIAR WITH THE SITE AND BUILDING PRIOR TO

PROPOSAL SUBMISSION. INCLUDE THE COST OF ALL WORK DESCRIBED

IN THE BIDDING DOCUMENTS AND THAT IS REQUIRED OR REASONABLY

IMPLIED TO ACHIEVE THE DESIGN INTENT OF THE BIDDING DOCUMENTS.

NOTIFY THE ROOF CONSULTANT OF ANY CONFLICTS BETWEEN EXISTING

CONDITIONS AND THE NEW WORK, OF ANY OMISSIONS OR CONFLICTS IN

THE DRAWINGS AND ANY RESTRICTIONS RELATED TO THE EXECUTION

OF THE WORK INCLUDING THE COORDINATION WITH OTHER TRADES.

4. PRODUCTS PROPOSED FOR USE AND PROJECT WORK SHALL BE IN

ACCORDANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL

GOVERNING ORDINANCES, CODES AND REGULATIONS. NOTIFY THE

OWNER IMMEDIATELY OF CONFLICTS BETWEEN THE SPECIFIED

PRODUCTS AND/OR PROJECT WORK REQUIREMENTS AND CODES,

ORDINANCES AND/OR REGULATIONS.

5. IF DISCREPANCIES ARE DISCOVERED WITHIN THE PROJECT MANUAL OR

DRAWINGS; THE OWNER, NOT THE CONTRACTOR, SHALL DETERMINE

THE INTENT OF THE DESIGN AND PROVIDE CLARIFICATION. NO

ALLOWANCE SHALL BE MADE FOR CONTRACTOR MISINTERPRETATION

OR IMPLIED MISINTERPRETATION OF THE PROJECT MANUAL AND

DRAWINGS.

6. REFER TO THE PROJECT MANUAL AND ROOFING SYSTEM

MANUFACTURER WRITTEN INSTRUCTIONS FOR FURTHER CLARIFICATION

OF PROJECT REQUIREMENTS. NOTIFY THE OWNER IMMEDIATELY OF

CONFLICTS BETWEEN THE SPECIFIED DESIGN REQUIREMENTS AND THE

WRITTEN REQUIREMENTS AND RECOMMENDATIONS OF THE ROOFING

SYSTEM MANUFACTURER.

7. CLOSE AND SEAL ABANDONED OPENINGS TO MATCH EXISTING

ADJACENT SURFACES WHERE MECHANICAL, PLUMBING, AND/OR

ELECTRICAL ITEMS ARE REMOVED.

8. CONTRACTOR SHALL TAKE NORMAL PRECAUTIONS SO THAT DEBRIS,

ROOFING MATERIAL, ETC., DOES NOT FALL INTO THE BUILDING OR ON

EQUIPMENT PER SECTIONS 014000 AND 015000.

SUMMARY OF ROOF REPLACEMENT WORK - AREAS A-I

A. ASBESTOS LABORATORY ANALYSIS REPORT: REFER TO SECTION 022623 FOR INFORMATION

RELATING TO THE LOCATION OF ACM, IF APPLICABLE, WITHIN PROJECT AREAS. IF POSITIVE, REFER

TO SECTIONS 013543 AND 028233 FOR PROCEDURES AND REQUIREMENTS RELATED TO THE

REMOVAL AND DISPOSAL OF NON-FRIABLE ASBESTOS RELATED TO THIS PROJECT.

B. ROOF REMOVAL AND SUBSTRATE PREPARATION: REMOVE EXISTING ROOF SYSTEM DOWN TO THE

STRUCTURAL DECK, INCLUDING ROOF MEMBRANE(S), AND UNDERLYING INSULATION,

UNDERLAYMENTS, AND ADDITIONAL ROOF MEMBRANES. INSPECT THE EXISTING STRUCTURAL

DECK, AND INFORM THE OWNER IMMEDIATELY OF OBSERVED DAMAGE AND OR DETERIORATION.

TEMPORARILY DISPLACE ROOFTOP EQUIPMENT AS NECESSARY TO COMPLETE THE SPECIFIED

WORK. REFER TO SECTIONS 024100 & 024102.

C. AFTER ROOF REMOVAL AND INSPECTION OF THE EXISTING STRUCTURAL DECK AND PERIMETER

WOOD BLOCKING, PERFORM REPAIRS TO THE STRUCTURAL DECK, AS DETERMINED NECESSARY

BY THE OWNER. REFER TO SECTIONS 030150 & 061516 & . REPLACE DAMAGED OR DETERIORATED

WOOD BLOCKING, AS DETERMINED NECESSARY BY THE OWNER. REFER TO SECTION 061053.

D. PROVIDE REQUIRED WOOD BLOCKING WHERE INDICATED ON THE PROJECT DRAWINGS. REFER TO

SECTION 061053.

E. ROOF AREAS A, B, C, D, E, F, H & I: PROVIDE AN UNDERLAYMENT CONSISTING OF A

SELF-ADHERING MEMBRANE. PRIOR TO APPLICATION, PREPARE AND PRIME THE DECK AS

REQUIRED BY THE ROOFING MEMBRANE MANUFACTURER. REFER TO SECTION 072215.

F. ROOF AREAS A, B, C & D: PROVIDE TWO LAYERS OF 2-1/2 INCH POLYISOCYANURATE INSULATION (5-INCHES TOTAL). IF INDICATED ON THE PROJECT DRAWINGS, PROVIDE INSULATION SADDLES

AND CRICKETS WHERE SHOWN. REFER TO SECTIONS 072221 FOR ADDITIONAL INSULATION

PRODUCT AND INSTALLATION REQUIREMENTS.

G. ROOF AREAS E, F & I: PROVIDE A TAPERED POLYISOCYANURATE INSULATION SYSTEM WITH AN INSULATION SYSTEM SLOPE OF 1/8-INCH PER FOOT, AND A STARTING THICKNESS OF 1/2-INCH

OVER A BASE LAYER OF 2-1/2 INCH POLYISOCYANURATE INSULATION. IF INDICATED ON THE

PROJECT DRAWINGS, PROVIDE INSULATION SADDLES AND CRICKETS WHERE SHOWN. REFER TO

SECTION 072221 FOR ADDITIONAL INSULATION PRODUCT AND INSTALLATION REQUIREMENTS.

H. ROOF AREA G: PROVIDE A LAYER OF 1-INCH POLYISOCYANURATE INSULATION. IF INDICATED ON

THE PROJECT DRAWINGS, PROVIDE INSULATION SADDLES AND CRICKETS WHERE SHOWN. REFER

TO SECTIONS 072221 FOR ADDITIONAL INSULATION PRODUCT AND INSTALLATION REQUIREMENTS.

I. ROOF AREA H: PROVIDE A COMPLETE ASPHALT SHINGLE ROOF SYSTEM; INCLUDING

UNDERLAYMENT, SELF-ADHERING MEMBRANE (ON ENTIRE ROOF SURFACE), ASPHALT SHINGLES,

AND BITUMINOUS AND SHEET METAL FLASHING ACCESSORIES. REFER TO SECTION 073113 FOR

PRODUCT AND INSTALLATION REQUIREMENTS.

J. ROOF AREAS A, B, C, D, E, F, G & I: PROVIDE A 1/2-INCH HIGH DENSITY POLYISO COVER BOARD OVER THE UNDERLYING INSULATION. REFER TO SECTIONS 072221 FOR ADDITIONAL PRODUCT AND

INSTALLATION REQUIREMENTS.

K. ROOF AREAS A, B, C, D, E, F, G & I: PROVIDE A FULLY-ADHERED, NOMINAL 60-MIL EPDM ROOF SYSTEM. AFTER INSTALLATION OF SPECIFIED INSULATION AND COVER BOARD, INSTALL THE EPDM

ROOFING MEMBRANE IN BONDING ADHESIVE. PROVIDE EPDM AND SHEET METAL FLASHINGS AS

SPECIFIED. PROVIDE AN ALTERNATE PRICE FOR A 20-YEAR, “TOTAL SYSTEM WARRANTY” FOR THE

ROOF SYSTEM. REFER TO SECTIONS 075323 AND 076205 FOR PRODUCT AND INSTALLATION

REQUIREMENTS.

1. ACCEPTABLE MANUFACTURERS:

a. CARLISLE

b. JOHNS MANVILLE

c. ELEVATE (FIRESTONE)

L. PROVIDE SEALANTS AT LOCATIONS INDICATED ON THE PROJECT DRAWINGS. REFER TO SECTION 079201.

M. EXISTING STONE COPINGS: CONTRACTOR SHALL RAKE AND RESEAL ALL VERTICAL AND

HORIZONTAL STONE COPING JOINTS.

INDEX OF DRAWINGS:

SHEET 01 OF 05

SHEET 02 OF 05

SHEET 03 OF 05

SHEET 04 OF 05

SHEET 05 OF 05

TITLE SHEET

GENERAL INFORMATION SHEET 01 OF 01

ROOF PLAN - AREAS A-I

ROOF PLAN DETAILS 01-09

ROOF PLAN DETAILS 10-15

XX

X

Testing Engineers & Consultants

1343 Rochester Road Troy, MI 48083

75% Design Review Set

Detroit Public Schools

3011 W. Grand Blvd Detroit, MI 48202

03-25-2026

Davison Elementary-Middle School

2800 E. Davison Detroit, MI 48212 roof hatch ladder replacement down ladder to area E possible down ladder to area D no building ladder for boiler building

PROFESSIONAL

PROJECT

DESCRIPTIONDATE

ISSUE

Drawn By: PD

Checked By: SH

SHEET TITLE

File Name:

STAMP

SHEET 02 OF 05

GENERAL

INFORMATION

SHEET 01 OF 01

PROJECT SPECIFIC KEY NOTES:

PROVIDE TAPERED DRAINAGE SUMPS AT ROOF DRAIN LOCATIONS INDICATED ON THE ROOF PLAN.

REFER TO DETAILS 03 AND SECTION 072221 FOR PRODUCT AND INSTALLATION REQUIREMENTS.

EXISTING CURBS: CONTRACTOR SHALL RAISE CURBS AS NEEDED TO ACHIEVE A MINIMUM FLASHING HEIGHT OF 8-INCHES. WHERE EXISTING CONDITIONS DO NOT ALLOW FOR THE RAISING OF CURBS, CONTRACTOR SHALL SEAL THE TOP EDGE OF THE FLASHING MEMBRANE AND TERM BAR WITH

MEMBRANE MANUFACTURER'S LIQUID APPLIED FLASHING SYSTEM.

AT LOCATIONS INDICATED ON THE ROOF PLAN, INSTALL SPECIFIED WALKWAY PAD APPROVED BY THE

ROOFING MEMBRANE MANUFACTURER. REFER TO THE ROOFING MEMBRANE SECTION FOR PRODUCT

AND INSTALLATION REQUIREMENTS.

EXISTING STONE COPINGS - CONTRACTOR SHALL RAKE & RESEAL ALL VERTICAL & HORIZONTAL

JOINTS - REFER TO DETAIL 07 & SECTION 079201

EXISTING ROOF HATCH - CONTRACTOR SHALL REMOVE AND DISPOSE OF EXISTING ROOF HATCH AND CURB - PROVIDE NEW ROOF HATCH WITH INTEGRATED, LADDER-UP SAFETY BAR & INTERNAL WALL

MOUNTED LADDER - REFER TO SECTION 075323 FOR PRODUCT REQUIREMENTS.

EXISTING CONCRETE CRICKETS & SADDLES - CONTRACTOR SHALL PROVIDE ADDITIONAL TAPERED

INSULATION TO ENHANCE CONCRETE CRICKETS & SADDLES FOR BETTER DRAINAGE.

EXISTING CLAY TILE COPINGS - CONTRACTOR TO REMOVE AND DISPOSE OF EXISTING CLAY TILE

COPING CAPS - PROVIDE THE NECESSARILY SUPPORT TO INSTALL WOOD NAILERS AND METAL

COPING CAPS - REFER TO DETAIL 09.

EXISTING CONDUIT/PIPING: CONTRACTOR SHALL TEMPORARILY DISPLACE TO ALLOW FOR

INSTALLATION OF NEW ROOFING SYSTEM - REINSTALL AND SET ON PRE-FABRICATED PIPE SUPPORTS

SET ON WALK PADS - REFER TO SECTION 075323 FOR PRODUCT REQUIREMENTS.

ROOF AREA H - CONTRACTOR SHALL REMOVE AND DISPOSE OF EXISTING FASCIA BOARD - PROVIDE

ALL NEW WOOD FASCIA BOARD.

A

Testing Engineers & Consultants

1343 Rochester Road Troy, MI 48083

COVER BOARD, INSULATION & UNDERLAYMENT ATTACHMENT

REQUIREMENTS:

PERIMETER AND CORNER DIMENSIONS OF A ROOF LESS THAN OR EQUAL TO 60 FEET IN HEIGHT ARE

DEFINED AS THE SMALLER OF:

· 0.1 TIMES THE BUILDING LESSER PLAN DIMENSION

· 0.4 TIMES THE EAVE HEIGHT

· THE TWO ABOVE DIMENSIONS ARE SUBJECT TO A MINIMUM WIDTH OF 4 PERCENT THE PLAN

DIMENSION OR 3 FEET

FIELD OF ROOF PERIMETERS CORNERS

COVER BOARD ADHERED IN TWO-PART

URETHANE FOAM

ADHESIVE 3/4" BEADS

12" O.C.

UNDERLAYMENT PRIME DECK (IF REQ'D

BY MANUFACTURER

AND ADHERE.

ADHERED IN TWO-PART

URETHANE FOAM

ADHESIVE 3/4" BEADS

6" O.C.

ADHERED IN TWO-PART

URETHANE FOAM

ADHESIVE 3/4" BEADS

4" O.C.

ADHERED IN TWO-PART

URETHANE FOAM

ADHESIVE 3/4" BEADS

12" O.C.

ADHERED IN TWO-PART

URETHANE FOAM

ADHESIVE 3/4" BEADS

6" O.C.

ADHERED IN TWO-PART

URETHANE FOAM

ADHESIVE 3/4" BEADS

4" O.C.

ADHERED IN TWO-PART

URETHANE FOAM

ADHESIVE 3/4" BEADS

12" O.C.

ADHERED IN TWO-PART

URETHANE FOAM

ADHESIVE 3/4" BEADS

6" O.C.

ADHERED IN TWO-PART

URETHANE FOAM

ADHESIVE 3/4" BEADS

4" O.C.

PRIME DECK (IF REQ'D

BY MANUFACTURER

AND ADHERE.

PRIME DECK (IF REQ'D

BY MANUFACTURER

AND ADHERE.

TOP INSULATION

LAYER

BOTTOM AND

INTERMEDIATE

INSULATION LAYER(S)

ATTACHMENT FOR

CONCRETE DECKS

EXISTING CONDITIONS:

NOTE: THE INFORMATION BELOW IS BASED ON RANDOM, LIMITED TEST CORES

MADE INTO THE ROOFING SYSTEM. CONDITIONS AT THE TEST CORE

LOCATIONS MAY NOT BE REPRESENTATIVE OF THE ENTIRE ROOF AREA.

IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY

EXISTING ROOF SYSTEM COMPONENTS AND SLOPE.

ROOF AREAS A, B, C & D

· BUR AGGREGATE

· 1-INCH FIBERGLASS

· HEAVY ASPHALT MOPPING

· CONCRETE DECK - 1/4-INCH OR GRATER PER FOOT SLOPE IN DECK

PROPOSED ROOF SYSTEMS:

NOTE: REFER TO SECTION 011000 - SUMMARY OF WORK, AND RELATED PROJECT

MANUAL SECTIONS FOR ADDITIONAL PRODUCT AND INSTALLATION

REQUIREMENTS FOR THE PROJECT.

PROPOSED ROOF SYSTEM - ROOF AREAS A, B, C & D (APPROX. 29,295 SF.):

· FULLY-ADHERED 60-MIL EPDM WITH 6-INCH SEAMS

· 1/2-INCH HIGH DENSITY POLYISO COVERBOARD - ADHERED AS SPECIFIED

· 2-1/2 INCH POLYISOCYANURATE INSULATION - ADHERED AS SPECIFIED

· 2-1/2 INCH POLYISOCYANURATE INSULATION - ADHERED AS SPECIFIED

· SELF-ADHERING UNDERLAYMENT

· EXISTING CONCRETE DECK - 1/4-INCH OR GREATER PER FOOT SLOPE IN DECK

Detroit Public Schools

3011 W. Grand Blvd Detroit, MI 48202

RECOMMENDED MAXIMUM L:W RATIOS FOR SADDLES AND CRICKETS

ROOF SLOPE SADDLE MATERIAL

SLOPE L:W RATIO

1/8 1/4 2:1

1/4 1/2 3:1

1/2 1 4:1

L

W

CRICKET DRAIN SUMP AREA

SADDLE

ROOF CURB

CRICKETS MUST BE USED ON THE UPHILL SLOPE OF

ANY CURB THAT IS GREATER THAN 24-INCHES

L

W

B

C

D

E

F

G

H

PROPOSED ROOF SYSTEM - ROOF AREAS E, F & I (APPROX. 2,625 SF.):

· FULLY-ADHERED 60-MIL EPDM WITH 6-INCH SEAMS

· 1/2-INCH HIGH DENSITY POLYISO COVERBOARD - ADHERED AS SPECIFIED

· 1/8-INCH PER FOOT TAPERED POLYISOCYANURATE INSULATION WITH A 1/2-INCH

STARTING THICKNESS- ADHERED AS SPECIFIED

· 2-1/2 INCH POLYISOCYANURATE INSULATION - ADHERED AS SPECIFIED

· SELF-ADHERING UNDERLAYMENT

· EXISTING CONCRETE DECK - 1/8-INCH OR PER FOOT SLOPE IN DECK

75% Design Review Set03-25-2026

Davison Elementary-Middle School

2800 E. Davison Detroit, MI 48212

I

PROPOSED ROOF SYSTEM - ROOF AREA G (APPROX. 299 SF.):

· FULLY-ADHERED 60-MIL EPDM WITH 6-INCH SEAMS

· 1/2-INCH HIGH DENSITY POLYISO COVERBOARD - ADHERED AS SPECIFIED

· 1-INCH POLYISOCYANURATE INSULATION - ADHERED AS SPECIFIED

· SELF-ADHERING UNDERLAYMENT

· EXISTING CONCRETE DECK - 1/8-INCH OR PER FOOT SLOPE IN DECK

PROPOSED ROOF SYSTEM - ROOF AREA H (APPROX. 100 SF.):

· SPECIFIED ASPHALT SHINGLES

· SELF-ADHERING UNDERLAYMENT

· EXISTING WOOD DECK - 4:12 SLOPE IN DECK

ROOF AREAS E, F, G & I

· BUR AGGREGATE

· 1-INCH FIBERGLASS

· HEAVY ASPHALT MOPPING

· CONCRETE DECK - 1/8-INCH OR GRATER PER FOOT SLOPE IN DECK

ROOF AREA H

· ASPHALT SHINGLES

· UNDERLAYMENTS

· WOOD DECK - 4:12 SLOPE IN DECK

ROOF PLAN - AREAS A-I

PROFESSIONAL

PROJECT

DESCRIPTIONDATE

ISSUE

Drawn By: PD

Checked By: SH

SHEET TITLE

File Name:

STAMP

SHEET 03 OF 05

ROOF PLAN

AREAS A-I

Testing Engineers & Consultants

1343 Rochester Road Troy, MI 48083

Detroit Public Schools

3011 W. Grand Blvd Detroit, MI 48202

76' 178'-6"

23'

13'-6"

25'-6"

62'

44'

10'

16'

4'-6"

43'

41'-6"

59'

12'

29'-6" 16'

20'

12'-6"

30' 40'

7'-6"

5'-6"

33'

11'

26'

14'-6"

12'

6'-6"

104'-6"

149'-6"102'-6"

23'-6"

8'8'

12'-6"

50'

23'-6"

1'-6"

75% Design Review Set03-25-2026

Davison Elementary-Middle School

2800 E. Davison Detroit, MI 48212

04 TYP.

3 SIDES

04 TYP.

04TYP.

04 TYP.

04 TYP.

04TYP.

04 TYP.

04 07

04 TYP.

TYP.

4 SIDES

04 07

TYP.

4 SIDES

ROOF AREA B

3,594 SF.

ROOF AREA A

11,125 SF.

ROOF AREA I

1,977 SF.

ROOF AREA C

13,951 SF.

ROOF AREA D

625 SF.

ROOF AREA G

299 SF.

ROOF AREA H

100 SF.

TYP.

4 SIDES

ROOF AREA F

493 SF.

ROOF AREA E

155 SF.

ATYP. ATYP.

ATYP.

ATYP.

BTYP.

B

C

E

G

FTYP.

FTYP.

D

D

D

D

D

I

WOOD BLOCKING - IF NECESSARY TO ACHIEVE

8-INCH MINIMUM FLASHING HEIGHT. SECURE TO

SUBSTRATE 18-INCHES O.C. AND WITHIN 2-INCHES

OF EACH END.

EXISTING ROOFTOP UNIT - TEMPORARILY DISPLACE

TO ALLOW FOR INSTALLATION OF NEW ROOF

SYSTEM AND RELATED FLASHING COMPONENTS.

REINSTALL TO ORIGINAL POSITION AFTER

COMPLETION OF WORK. RE-SECURE TO EXISTING

CURB WITH GASKETED FASTENERS 12-INCHES O.C.

MAX., AND WITHIN 2-INCHES OF EACH CORNER.

CURB INSULATION - IF EXISTING

CURB IS INSULATED, AND

EXISTING INSULATION CANNOT BE

SALVAGED, PROVIDE CURB

INSULATION TO MATCH EXISTING.

PREFINISHED 24 GA. GALV. STEEL

SURFACE-MOUNTED

COUNTERFLASHING. SECURE TO

EXISTING CURB COUNTERFLASHING

AS SHOWN USING GASKETED

FASTENERS 12-INCHES O.C. MAX.,

AND WITHIN 2-INCHES OF EACH END.

SELF-ADHERING MEMBRANE

COMPATIBLE WITH EXISTING

SUBSTRATE(S)

REFER TO DETAILS BELOW FOR

FLASHING REQUIREMENTS.

ALT. COUNTERFLASHING NO. 2

FOR USE WHERE APPROVED AND WHERE

EXISTING CURB IS SEPARATED FROM THE

EXISTING ROOFTOP PENETRATION

BUTYL TAPE - INSTALL BEHIND

COUNTERFLASHING

SEALANT

NOTE: SECURE TOP EDGE OF FLASHING USING AN

ALUMINUM TERMINATION BAR SECURED

12-INCHES O.C., MAX., AND WITHIN

2-INCHES OF EACH END. PRIOR TO

TERMINATION BAR INSTALLATION, INSTALL

MANUFACTURERS RECOMMENDED

SEALANT BEHIND FLASHING WHERE

TERMINATION BAR WILL BE PLACED. SEAL

TOP EDGE OF FLASHING AND TERMINATION

BAR AFTER INSTALLATION.

NOTE: INSTALL INSIDE AND OUTSIDE FLASHING

CORNERS FOLLOWING THE

RECOMMENDATIONS AND REQUIREMENTS

OF THE ROOFING MEMBRANE

MANUFACTURER. PROVIDE "T-JOINT

COVERS" AT THE BASE OF THE CURB AT

FLASHING PIECE INTERSECTIONS.

ALT. VERTICAL MEMBRANE TERMINATION

FOR USE WHERE HORIZONTAL TERMINATION OF

EPDM MEMBRANE IS NOT POSSIBLE

4" M

IN

4" M

IN

8" M

IN

FL

AS

H

IN

G H

EI

G

H T

NOTE: DIS-CONNECTIONS AND RE-CONNECTIONS

OF ELECTRICAL, PLUMBING OR

MECHANICAL CONNECTIONS RELATED TO

THE DISPLACEMENT AND RE-INSTALLATION

OF ROOFTOP UNITS SHALL BE PERFORMED

BY A CONTRACTOR LICENSED TO PERFORM

SUCH WORK. COORDINATE THIS WORK

WITH THE OWNER.

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT

SHOWN FOR CLARITY.

EXISTING STRUCTURAL DECK

COVER BOARD - 1/2-INCH THICK

EPDM ROOFING MEMBRANE

REINFORCED PERIMETER FASTENING STRIP WITH

FACTORY-LAMINATED SEAM TAPE. PRIME EPDM

MEMBRANE PRIOR TO APPLICATION TO REINFORCED

FASTENING STRIP.

FASTENERS AND 2-INCH PLATES, 6-INCHES O.C. MAX.

EPDM MEMBRANE, 8" MIN. HEIGHT, FULLY

ADHERED TO CURB. REFER TO NOTE

REGARDING SECUREMENT OF MEMBRANE.

EPDM ROOFING MEMBRANE

REINFORCED PERIMETER FASTENING STRIP WITH

FACTORY-LAMINATED SEAM TAPE. PRIME EPDM

MEMBRANE PRIOR TO APPLICATION TO REINFORCED

FASTENING STRIP.

BATTEN STRIP OR FASTENERS AND 2-INCH PLATES,

12-INCHES O.C. MAX.

1-1/4" 1/2"

APPR

O

X.

2-3/4"

EPDM MEMBRANE, FULLY ADHERED TO CURB. 8" MIN.

HEIGHT, REFER TO NOTE REGARDING SECUREMENT

OF FLASHING.

APPROX.

1/2"

ALT. VERTICAL TERMINATION -

TWO PIECE FLASHING

FOR USE WHERE HORIZONTAL TERMINATION OF

EPDM MEMBRANE IS NOT POSSIBLE

APPROX.

1/2"

EPDM ROOFING MEMBRANE

SEAM TAPE - 6-INCH WIDTH. APPLY PRIMER TO

UNDERLYING EPDM ROOF MEMBRANE AND OVERLYING

EPDM FLASHING MEMBRANE PRIOR TO APPLICATION.

1-1/4" 1/2"

2-3/4"

2"

PRESSURE-SENSITIVE OUTERSEAM FLASHING;

MINIMUM 5-INCH WIDTH. SEAL EDGES AS SHOWN.

EPDM ROOFING MEMBRANE

SEAM TAPE - 6-INCH WIDTH. APPLY PRIMER

TO UNDERLYING EPDM ROOF MEMBRANE

AND OVERLYING EPDM FLASHING

MEMBRANE PRIOR TO APPLICATION.

BATTEN STRIP OR FASTENERS AND 2-INCH

PLATES, 12-INCHES O.C. MAX.

PRESSURE-SENSITIVE OUTERSEAM

FLASHING; MIN. 5-INCH WIDTH. SEAL

EDGES AS SHOWN.

4" M

IN

WRAP EPDM MEMBRANE FLASHING OVER

THE TOP OF THE CURB AND SECURE TO

THE INSIDE OF THE CURB WITH 1" METAL

CAP NAILS AT 6" O.C. MAXIMUM.

MEMBRANE SECUREMENT

ALT. TWO-PIECE FLASHING

PREFINISHED 24 GA. GALV.

STEEL SLIP COUNTERFLASHING.

SECURE TO EXISTING CURB

COUNTERFLASHING AS SHOWN

USING GASKETED FASTENERS

12-INCHES O.C. MAX., AND

WITHIN 2-INCHES OF EACH END.

EXISTING ROOFTOP UNIT

COUNTERFLASIHNG

REFER TO DETAILS BELOW FOR

FLASHING REQUIREMENTS.

ALT. COUNTERFLASHING NO. 1

FOR USE WHERE APPROVED AND WHERE EXISTING

ROOFTOP UNIT CANNOT BE DISPLACED TO ALLOW FOR

FLASHING, OR WHERE GAP BETWEEN EXISTING

ROOFTOP UNIT COUNTERFLASHING AND CURB IS TOO

NARROW TO ACCOMMODATE FLASHING

4" M

IN

8" M

IN

FL

AS

H

IN

G H

EI

G

H T

EXIST. ROOFTOP PENETRATION

EPDM FLASHING, 8" MIN. HEIGHT, FULLY

ADHERED TO CURB. REFER TO NOTE

REGARDING SECUREMENT OF MEMBRANE.

ALT. NOTE:

ALT. SECUREMENT

SPECIFIED POLYISO. INSULATION

UNDERLAYMENT - CONCRETE DECKS ONLY

APPR

O

X.

2-3/4"

8" M

IN

IM

U M

H

EI

G H

T

NOTE: DIS-CONNECTIONS AND RE-CONNECTIONS OF ELECTRICAL,

PLUMBING OR MECHANICAL COMPONENTS RELATED TO

THE DISPLACEMENT AND RE-INSTALLATION OF ROOFTOP

UNITS SHALL BE PERFORMED BY A CONTRACTOR LICENSED

TO PERFORM SUCH WORK. COORDINATE THIS WORK WITH

THE OWNER.

NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN

24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER

THE REQUIREMENTS AND RECOMMENDATIONS OF THE

EPDM ROOFING MEMBRANE MANUFACTURER.

NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS

FOLLOWING THE RECOMMENDATIONS AND REQUIREMENTS

OF THE ROOFING MEMBRANE MANUFACTURER. PROVIDE

"T-JOINT COVERS" AT THE BASE OF THE CURB AT FLASHING

PIECE INTERSECTIONS.

NOTE: APPLY WATER CUT OFF MASTIC TO THE BACKSIDE OF

FLASHING PRIOR TO COUNTERFLASIHNG INSTALLATION.

USE COUNTERFLASHING AS SECUREMENT PIECE FOR

FLASHING AS SHOWN.

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR

CLARITY.

SPECIFIED POLYISOCYANURATE INSULATION

EXISTING STRUCTURAL DECK

COVER BOARD - 1/2-INCH THICK

EPDM ROOFING MEMBRANE

APPROX.

1/2"

EPDM FLASHING MEMBRANE, FULLY ADHERED TO CURB. REFER TO

NOTE REGARDING SECUREMENT OF FLASHING.

REINFORCED PERIMETER FASTENING STRIP WITH FACTORY-LAMINATED

SEAM TAPE. PRIME EPDM MEMBRANE PRIOR TO APPLICATION TO REINFORCED

FASTENING STRIP.

FASTENERS AND 2-INCH PLATES, 12-INCHES O.C. MAX.

NEW ROOF HATCH ON CURB -

RAISE TO ACCOMMODATE NEW

ROOF SYSTEM ELEVATION, AND

RE-SECURE FLANGE TO WOOD

BLOCKING AS SHOWN. PROVIDE

INTERIOR FINISH REPAIRS AS

NEEDED TO ACCOMMODATE

RAISING OF CURB.

NOMINAL WOOD BLOCKING.

THICKNESS TO MATCH EXISTING

COVER BOARD AND INSULATION

THICKNESS; WIDTH GREATER

THAN ROOF HATCH CURB AND

CURB FLANGE. SECURE TO

SUBSTRATE 18-INCHES O.C.

WITH SPECIFIED FASTENERS

APPROPRIATE FOR THE

SUBSTRATE ENCOUNTERED.

PREFINISHED 24 GA. GALV.

STEEL SLIP COUNTERFLASHING.

SECURE TO EXISTING CURB

COUNTERFLASHING AS SHOWN

USING GASKETED FASTENERS

12-INCHES O.C. MAX., AND

WITHIN 2-INCHES OF EACH END.

APPLY SEALANT TO BACKSIDE

OF COUNTERFLASHING PRIOR

TO INSTALLATION.

CL

NOTE: PRIOR TO SOLDERING OF STAINLESS STEEL, CLEAN WORK AREA USING SOLVENTS

AND WIRE BRUSH; REMOVING DIRT, OIL, GREASE, AND OTHER CONTAMINANTS FROM

THE WORK AREA. TIN THE WORK AREA BY APPLYING ACID (FLUX). PERFORM

SOLDERING WORK. AFTER COMPLETION OF WORK, REMOVE EXCESS ACID (FLUX)

FROM THE WORK AREA.

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR

CLARITY.

CL

MIN. 1" AIR

GAP OR MATCH

EXIST. - WHICHEVER

IS GREATER

4" M

IN

8" M

IN

. F

LA

SH

IN

G

H

EI

G H

T

FIELD-FABRICATED

FLASHING

HOT STACK

NOTE: APPLY PRIMER TO ALL SURFACES WHICH WILL

RECEIVE PRESSURE SENSITIVE OUTER SEAM

FLASHING PRIOR TO APPLICATION.

3" MIN3" MIN

2 1/2"

NOTE: WHEN OUTSIDE DIAMETER OF THE PIPE

EXCEEDS 18", ADDITIONAL FIELD MEMBRANE

SECUREMENT REQUIRED. REFER TO

MANUFACTURER'S DETAILS.

PRESSURE-SENSITIVE

FLASHING - 12-INCH WIDTH.

PRESSURE-SENSITIVE

FLASHING - 9-INCH WIDTH.

PRESSURE-SENSITIVE

FLASHING - 5 OR 6-INCH

WIDTH.

PRESSURE-SENSITIVE

OUTERSEAM FLASHING;

6-INCH WIDTH. SEAL

EDGES AS SHOWN.

PRE-FABRICATED

BOOT FLASHING

EXISTING TUBULAR

PENETRATION

PIPE EXTENSION (IF NECESSARY) TO

ACHIEVE 8" MIN. FLASHING HEIGHT.

PROVIDE SEALANT AT INTERSECTION

BETWEEN EXISTING TUBULAR

PENETRATION AND EXTENSION.

24 GA. STAINLESS STEEL STORM COLLAR

SOLDER ALL LAPS AND SEAMS WATERTIGHT.

REFER TO NOTE REGARDING SOLDERING.

INSTALL BUTYL TAPE BEHIND COLLAR AS

SHOWN PRIOR TO INSTALLATION OF CLAMP.

SEAL TOP OF HOOD AS SHOWN.

SEALANT - TYP

STAINLESS STEEL CLAMPING

BAND

STAINLESS STEEL CLAMPING BAND.

PRIOR TO INSTALLATION, APPLY

MANUFACTURERS RECOMMENDED

SEALANT BEHIND EPDM FLASHING.

SEAL TOP OF FLASHING AND BAND

AFTER INSTALLATION.

EXISTING HIGH-TEMPERATURE

TUBULAR PENETRATION

PRESSURE-SENSITIVE FLASHING - 12-INCH

WIDTH.

PRESSURE-SENSITIVE FLASHING - 9-INCH

WIDTH.

PRESSURE-SENSITIVE FLASHING - 5 OR

6-INCH WIDTH.

PRESSURE-SENSITIVE OUTERSEAM

FLASHING; 6-INCH WIDTH. SEAL EDGES

AS SHOWN.

HIGH TEMPERATURE

SEALANT - TYP

STAINLESS STEEL

CLAMPING BAND

SPECIFIED POLYISOCYANURATE INSULATION - TYP.

EXISTING STRUCTURAL DECK - TYP.

COVER BOARD - 1/2-INCH THICK - TYP.

EPDM ROOFING MEMBRANE - TYP.

UNDERLAYMENT - TYP. - CONCRETE DECKS ONLY

24 GA. STAINLESS STEEL STORM COLLAR

SOLDER ALL LAPS AND SEAMS

WATERTIGHT. REFER TO NOTE

REGARDING SOLDERING. INSTALL BUTYL

TAPE BEHIND COLLAR AS SHOWN PRIOR

TO INSTALLATION OF CLAMP. SEAL TOP

OF HOOD AS SHOWN.

24 GA. STAINLESS STEEL FLANGED

SLEEVE. SOLDER ALL LAPS AND SEAMS

WATERTIGHT. REFER TO NOTE

REGARDING SOLDERING. SECURE TO

STRUCTURAL DECK AS SHOWN.

NOTE: EXISTING FLANGED SLEEVE

COMPONENTS DETERMINED TO BE IN

GOOD CONDITION AND FREE OF

BITUMINOUS CONTAMINATION MAY BE

CONSIDERED FOR RE-USE.

POURABLE SEALER - SLOPE TO ALLOW FOR PROPER DRAINAGE.

NON-SHRINK GROUT - FILL TO 2" BELOW RIM OF PITCH PAN.

EXISTING IRREGULAR PENETRATION - SIZE AND SHAPE VARIES.

NOTE: DO NOT USE PITCH PANS AT TUBULAR PENETRATIONS

WITHOUT PRIOR OWNER APPROVAL.

SPECIFIED POLYISOCYANURATE INSULATION

EXISTING STRUCTURAL DECK

COVER BOARD - 1/2-INCH THICK

EPDM ROOFING MEMBRANE

4" M

IN

NOTE: PRIOR TO SOLDERING OF STAINLESS STEEL, CLEAN WORK

AREA USING SOLVENTS AND WIRE BRUSH; REMOVING DIRT,

OIL, GREASE, AND OTHER CONTAMINANTS FROM THE WORK

AREA. TIN THE WORK AREA BY APPLYING ACID (FLUX).

PERFORM SOLDERING WORK. AFTER COMPLETION OF

WORK, REMOVE EXCESS ACID (FLUX) FROM THE WORK

AREA.

AT LOCATIONS WHERE POSSIBLE, PROVIDE A 24 GA. STAINLESS

STEEL JUNCTION/FLASHING BOX. FABRICATE BOX WITH A SLOPED

TOP TO SHED WATER. SOLDER ALL LAPS AND SEAMS WATERTIGHT.

SEAL PENETRATION EXIT OPENINGS WATERTIGHT.

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR

CLARITY.

PRESSURE-SENSITIVE FLASHING - WIDTH AS NECESSARY TO RESULT

IN CONDITION SHOWN.

PRESSURE-SENSITIVE OUTERSEAM FLASHING; WIDTH AS NECESSARY TO

RESULT IN CONDITION SHOWN. SEAL EDGES AS SHOWN.

NOMINAL 6-INCH WOOD BLOCKING AS NECESSARY TO MATCH COVER

BOARD AND INSULATION THICKNESS. SECURE TO SUBSTRATE

18-INCHES O.C. MAX., AND WITHIN 2-INCHES OF EACH END.

4" MIN.

24 GA. STAINLESS STEEL PITCH PAN WITH 6-INCH FLANGE AND ROUNDED

CORNERS. SOLDER ALL SEAMS AND LAPS WATERTIGHT - REFER TO NOTE

REGARDING SOLDERING.

2" MIN. ALL SIDES

NOTE: APPLY PRIMER TO ALL SURFACES WHICH WILL

RECEIVE PRESSURE SENSITIVE OUTER SEAM

FLASHING PRIOR TO APPLICATION..

UNDERLAYMENT

4" M

IN

8" M

IN

SPECIFIED POLYISOCYANURATE INSULATION

EXISTING STRUCTURAL DECK

EPDM ROOFING MEMBRANE

REINFORCED PERIMETER FASTENING

STRIP WITH FACTORY-LAMINATED SEAM

TAPE. PRIME EPDM MEMBRANE PRIOR TO

APPLICATION TO REINFORCED FASTENING

STRIP.

EPDM FLASHING MEMBRANE, FULLY

ADHERED TO CURB

FASTENERS AND 2-INCH PLATES,

12-INCHES O.C. MAX.

COVER BOARD - 1/2-INCH THICK

APPROX.

1/2"

NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS FOLLOWING

THE RECOMMENDATIONS AND REQUIREMENTS OF THE ROOFING

MEMBRANE MANUFACTURER. PROVIDE "T-JOINT COVERS" AT THE

BASE OF THE CURB AT FLASHING PIECE INTERSECTIONS.

NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND

COUNTERFLASHING, INSPECT EXISTING WALLS FOR THE

PRESENCE OF MASONRY WEEPS AND OTHER WALL DRAINAGE

MECHANISMS. DO NOT COVER WEEPS, OR IMPEDE THE ABILITY

OF MOISTURE TO EXIT WALL SYSTEMS.

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR

CLARITY.

3/4-INCH PLYWOOD MECHANICALLY ATTACHED TO EXISTING

WALL WITH PROPER SUBSTRATE FASTENERS - TWO ROWS

24-INCHES O.C., STAGGERED

CUT REGLET INTO WALL AS SHOWN.

REFER TO ENLARGED REGLET DETAIL

FOR FURTHER CLARIFICATION.

PREFINISHED 24 GA. GALV. STEEL

COUNTERFLASHING, SPRING-LOCKED INTO

REGLET AND SECURED WITH GASKETED

FASTENERS APPROPRIATE FOR THE

SUBSTRATE 12-INCHES O.C. MAX. REFER TO

ENLARGED REGLET DETAIL.

EXISTING WALL

ENLARGED REGLET

DETAIL

SCALE: NONE

CUT REGLET INTO WALL

AS SHOWN

SEALANT

PREFINISHED 24 GA. GALV.

STEEL COUNTERFLASHING,

SPRING-LOCKED INTO REGLET

AND SECURED WITH GASKETED

FASTENERS APPROPRIATE FOR

THE SUBSTRATE 12-INCHES O.C.

MAX.

FU

LL W

ID

TH

O F M

ASO

N

R Y

G R

O U

T JO

IN

T

APPR

O

X.

1-1/4"

APPROX. 1"

DEEP

UNDERLAYMENT

NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN

24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER THE

REQUIREMENTS AND RECOMMENDATIONS OF THE EPDM

ROOFING MEMBRANE MANUFACTURER.

SECURE TOP EDGE OF FLASHING USING AN ALUMINUM

TERMINATION BAR SECURED 12-INCHES O.C., MAX., AND WITHIN

2-INCHES OF EACH END. PRIOR TO TERMINATION BAR

INSTALLATION, INSTALL MANUFACTURERS RECOMMENDED

SEALANT BEHIND FLASHING WHERE TERMINATION BAR WILL BE

PLACED. SEAL TOP EDGE OF FLASHING AND TERMINATION BAR

AFTER INSTALLATION.

NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN

24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER

THE REQUIREMENTS AND RECOMMENDATIONS OF THE

EPDM ROOFING MEMBRANE MANUFACTURER.

NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS FOLLOWING

THE RECOMMENDATIONS AND REQUIREMENTS OF THE ROOFING

MEMBRANE MANUFACTURER. PROVIDE "T-JOINT COVERS" AT THE

BASE OF THE CURB AT FLASHING PIECE INTERSECTIONS.

NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND

COUNTERFLASHING, INSPECT EXISTING WALLS FOR THE

PRESENCE OF MASONRY WEEPS AND OTHER WALL DRAINAGE

MECHANISMS. DO NOT COVER WEEPS, OR IMPEDE THE ABILITY

OF MOISTURE TO EXIT WALL SYSTEMS.

4" M

IN

8" M

IN

IM

U M

JOINT WIDTH

SEALANT DEPTH: WHEN JOINT WIDTH IS LESS THAN

OR EQUAL TO 1/2-INCH, SEALANT DEPTH SHALL BE

1/4-INCH. WHEN JOINT WIDTH IS BETWEEN 1/2-INCH

AND 1-INCH, SEALANT DEPTH SHALL EQUAL

ONE-HALF THE JOINT WIDTH. WHEN JOINT WIDTH IS

BETWEEN 1-INCH AND 2-INCHES, SEALANT DEPTH

SHALL EQUAL 1/2-INCH.

SEALANT

COMPRESSIBLE BACKER ROD

EXISTING STONE COPING - BOTH

SIDES OF JOINT. PREPARE SURFACES

ADJACENT TO JOINT AS REQ'D BY SEALANT

MANUFACTURER. PRIME SURFACES IF

REQUIRED BY SEALANT MANUFACTURER.

EXISTING COPING JOINT - REMOVE EXISTING

SEALANT AND OTHER REPAIR MATERIALS

PRIOR TO INSTALLATION OF NEW MATERIALS.

STONE COPING SEALANT JOINT RAKE AND

RE-SEAL DETAIL

FOR USE WHERE VERTICAL AND HORIZONTAL STONE COPING JOINTS

ARE TO BE RE-SEALED.

1- 1/

2" M

IN

SPECIFIED POLYISOCYANURATE INSULATION

EXISTING STRUCTURAL DECK

EPDM ROOFING MEMBRANE

REINFORCED PERIMETER FASTENING

STRIP WITH FACTORY-LAMINATED SEAM

TAPE. PRIME EPDM MEMBRANE PRIOR TO

APPLICATION TO REINFORCED FASTENING

STRIP.

EPDM FLASHING MEMBRANE, FULLY

ADHERED TO CURB

FASTENERS AND 2-INCH PLATES,

12-INCHES O.C. MAX.

COVER BOARD - 1/2-INCH THICK

APPROX.

1/2"

3/4-INCH PLYWOOD MECHANICALLY ATTACHED TO EXISTING

WALL WITH PROPER SUBSTRATE FASTENERS - TWO ROWS

24-INCHES O.C., STAGGERED

SPECIFIED UNDERLAYMENT - CONCRETE DECKS ONLY

PREFINISHED 24 GA. GALV. STEEL SURFACE

MOUNTED COUNTERFLASHING. SECURE TO

EXISTING WALL AS SHOWN USING GASKETED

FASTENERS 12-INCHES O.C. MAX., AND WITHIN

2-INCHES OF EACH END.

SEALANT

EXISTING STONE COPING CAP. RAKE AND RE-SEAL

VERTICAL AND HORIZONTAL JOINTS IN CAP. REFER

TO ADJACENT DETAIL FOR FURTHER

CLARIFICATION.

SECURE TOP EDGE OF FLASHING USING AN ALUMINUM

TERMINATION BAR SECURED 12-INCHES O.C., MAX., AND

WITHIN 2-INCHES OF EACH END. PRIOR TO TERMINATION

BAR INSTALLATION, INSTALL MANUFACTURERS

RECOMMENDED SEALANT BEHIND FLASHING WHERE

TERMINATION BAR WILL BE PLACED. SEAL TOP EDGE OF

FLASHING AND TERMINATION BAR AFTER INSTALLATION.

CREATE A 3-FOOT ENHANCED DRAINAGE AREA WITH A MINIMUM FINISH SLOPE OF 1/2-INCH PER FOOT

AT GUTTER EDGES. CONSTRUCT THE AREA USING A TAPERED POLYISOCYANURATE INSULATION

"Q-PANEL" CUT TO CREATE A FLUSH CONDITION AT THE EDGE NAILER(S) AND INSULATION.

8"

8"

3" M

IN

2" M

IN

. O

R T

O M

AT

C

H E

XI

ST

IN

G

E

LE

VA

TI

O N

W H

IC

H

EV

ER

IS

G

R

EA

TE

R

2"2" M

IN

4"

1/2" HUG

GUTTER EDGE FLANGE CONFIGURATION

AND NAILING PATTERN DIAGRAM

SCALE: NONE

NOTE: THE PURPOSE OF THIS DIAGRAM IS

TO SHOW GUTTER EDGE FASCIA FLANGE

FASTENING PATTERNS AND NAILER

CONFIGURATION. THE ACTUAL FASCIA

CONFIGURATION, SIZE OF NAILERS, AND

NUMBER OF NAILERS REQUIRED TO

ACHIEVE THE REQUIREMENTS SHOWN IN

THE DETAIL BELOW WILL VARY.

3" MIN.

4" FLANGE

1/2" HUG

6" MIN.

1/2" MIN.

NOTE: EXTEND EPDM ROOFING MEMBRANE OVER AND DOWN

PERIMETER EDGE AS SHOWN. SECURE WITH ROOFING

NAILS AFFIXED WITH 1" DIAMETER METAL CAPS 12" O.C.

MAX.

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR

CLARITY.

DOWNSPOUT RECEIVER PIECE - FABRICATE USING PREFINISHED 24 GA.

GALV. STEEL. FASTEN AND SEAL TO GUTTER AS SHOWN.

PREFINISHED 24 GA. GALV. STEEL FASCIA EXTENSION PIECE. SECURE

TO SUBSTRATE WITH SPECIFIED FASTENER APPROPRIATE FOR THE

SUBSTRATE ENCOUNTERED 12" O.C. MAX.

PROVIDE GUTTER HANGERS 30-INCHES O.C. - FABRICATE FROM 1-INCH X

1/8-INCH GALV. STEEL, PAINTED TO MATCH GUTTER. SECURE TO

SUBSTRATE WITH FASTENERS APPROPRIATE FOR THE SUBSTRATE

ENCOUNTERED. SECURE WITH TWO FASTENERS, MINIMUM, PER HANGER.

UNDERLAYMENT - CONCRETE DECKS ONLY

PRESSURE-SENSITIVE OUTER SEAM FLASHING - 5-INCH OR

6-INCH WIDTH.

NOTE: AT A MINIMUM, PROVIDE AN ADDITIONAL 6" WIDE

REINFORCEMENT PIECE AT SHEET METAL FASCIA JOINTS.

REFER TO ROOFING MEMBRANE MANUFACTURER

REQUIREMENTS FOR ADDITIONAL REQUIREMENTS AND

RECOMMENDATIONS AT SHEET METAL FASCIA JOINTS.

NOMINAL 6-INCH WOOD BLOCKING - THICKNESS AS NECESSARY TO

MATCH MAXIMUM ROOF AREA INSULATION AND COVER BOARD

THICKNESS WITH A CONSISTENT FINAL NAILER ELEVATION. SECURE

TO SUBSTRATE 18-INCHES O.C. MAX. DECREASE FASTENER SPACING

TO 9-INCHES O.C. WITHIN 10-FEET OF A BUILDING CORNER.

EXISTING STRUCTURAL DECK

SPECIFIED POLYISOCYANURATE INSULATION

COVER BOARD - 1/2-INCH THICK

EPDM ROOFING MEMBRANE

TAPERED POLYISOCYANURATE INSULATION

MINIMUM STARTING THICKNESS OF 1-INCH

GUTTER FABRICATED FROM 24 GA.

PREFINISHED GALV. STEEL. OVERLAP

GUTTER SECTIONS 1-1/2 INCH, SEAL, AND

POP RIVET SECTIONS WITH TWO ROWS OF

POP RIVETS, SPACED 1/2"-3/4" O.C. IN EACH

ROW. SECURE BACK VERTICAL FLANGE

TO SUBSTRATE 18" O.C. MAX.

GUTTER SPACERS - 1/8-NCH THICK X 1-INCH

WIDE, 30-INCHES O.C. MAX. FABRICATE

FROM GALVANIZED STEEL. PAINT SPACERS

TO MATCH GUTTER COLOR. SEAL AND

SECURE TO GUTTER.

PREFINISHED 24 GA. GALV. STEEL FASCIA

PIECE. FABRICATE WITH 4-INCH FLANGE

AND 1/2-INCH HUG AS SHOWN. SECURE

FLANGE WITH NAILS 3-INCHES O.C. MAX. IN

TWO STAGGERED ROWS AS SHOWN IN

DIAGRAM AT TOP RIGHT CORNER OF

SHEET.

PRESSURE-SENSITIVE OUTER SEAM

FLASHING - 9-INCH WIDTH. SEAL EDGES

AS SHOWN AFTER COMPLETION OF

WORK.

PREFINISHED 24 GA. GALV. STEEL RECTANGULAR DOWNSPOUT.

FABRICATE AND INSTALL DOWNSPOUTS IN ACCORDANCE WITH

“SMACNA ARCHITECTURAL SHEET METAL MANUAL, 7TH EDITION”.

SECURE DOWNSPOUT TO WALL WITH BRACKETS AND

FASTENERS APPROPRIATE FOR THE SUBSTRATE ENCOUNTERED.

TERMINATE BOTTOM OF DOWNSPOUT TO MATCH EXISTING.

LCC

PLAN VIEW OF ROOF SUMP AREA

SCALE: NONE

TAPERED INSULATION/EDGE STRIPS AS NEEDED

TO RESULT IN 8'-0" X 8'-0" SUMP AREA

ROOF DRAIN

NOTE: EXTEND EPDM ROOFING MEMBRANE UNDER CLAMPING

RING AND INTO THE ROOF DRAIN. TIGHTLY SECURE

CLAMPING RING AFTER INSTALLATION OF ROOF DRAIN

FLASHING COMPONENTS.

CUT DRAINAGE HOLE IN MEMBRANE MIN. 1/2" GREATER

THAN DRAIN PIPE DIAM. ON ALL SIDES

EXTEND MEMBRANE 1" MIN.

BEYOND CLAMPING RING

IN

ST

AL

L

TA

PE

R

ED

P O

LY

IS

O C

YA

N

U R

AT

E

IN

SU

LA

TI

O N

A N

D /O

R T

AP

ER

ED

E

D G

E

ST

R

IP

T O

R

ES

U

LT

IN

' x

' S U

M P

AR

EA

(T

YP

APPROX. 4'-0" - REFER TO NOTE ABOVE REGARDING ROOF SUMP AREA

CONSTRUCTION AND SLOPE REQUIREMENTS

IN

ST

AL

L

TA

PE

R

ED

P O

LY

IS

O C

YA

N

U R

AT

E

IN

SU

LA

TI

O N

A N

D /O

R T

AP

ER

ED

E

D G

E

ST

R

IP

T O

R

ES

U

LT

IN

' x

' S U

M P

AR

EA

(T

YP

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR

CLARITY.

EXISTING STRUCTURAL DECK

SPECIFIED POLYISOCYANURATE INSULATION

COVER BOARD - 1/2-INCH THICK

EPDM ROOFING MEMBRANE

TAPERED POLYISOCYANURATE INSULATION, AND/OR

TAPERED EDGE STRIP(S) AS NECESSARY TO RESULT IN A

8-FOOT BY 8-FOOT MINIMUM TAPERED ROOF DRAIN SUMP

AREA WITH A MINIMUM SLOPE OF 1/4-INCH PER FOOT.

EXISTING ROOF DRAIN ASSEMBLY. CLEAN BOWL FREE OF ALL

EXISTING FLASHING MATERIALS AND BITUMINOUS RESIDUE PRIOR

TO INSTALLATION OF EPDM ROOFING MEMBRANE AND

MANUFACTURER'S RECOMMENDED SEALANT. INSPECT DRAIN

BOWL, CLAMPING RING, AND OTHER ASSEMBLY COMPONENTS FOR

DAMAGE. REPLACE DAMAGED COMPONENTS AS NECESSARY PER

SECTION 024100.

EXISTING ROOF DRAIN STRAINER. REMOVE AND DISCARD

DAMAGED, BROKEN OR PLASTIC-TYPE STRAINER(S).

REPLACE DISCARDED STRAINERS WITH CAST IRON

STRAINERS. REFER TO SECTION 024100.

NOTE: EXTEND EPDM ROOFING MEMBRANE UNDER CLAMPING

RING AND INTO THE ROOF DRAIN. TIGHTLY SECURE

CLAMPING RING AFTER INSTALLATION OF ROOF DRAIN

FLASHING COMPONENTS.

MANUFACTURER'S RECOMMENDED SEALANT. INSTALL ONE TUBE,

MINIMUM, UNDER EPDM ROOFING MEMBRANE AT CLAMPING RING,

CONTINUOUS BEAD - TO ROOF DRAIN ASSEMBLY INTERSECTION.

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR

CLARITY.

NOTE: IF FIELD SEAM EDGE IS WITHIN 9" OF DRAIN COMPRESSION

RING, EPDM TARGET PATCH REQUIRED.

UNDERLAYMENT

NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN

24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER

THE REQUIREMENTS AND RECOMMENDATIONS OF THE

EPDM ROOFING MEMBRANE MANUFACTURER.

NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS FOLLOWING

THE RECOMMENDATIONS AND REQUIREMENTS OF THE ROOFING

MEMBRANE MANUFACTURER. PROVIDE "T-JOINT COVERS" AT THE

BASE OF THE WALL AT FLASHING PIECE INTERSECTIONS.

NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND

COUNTERFLASHING, INSPECT EXISTING WALLS FOR THE

PRESENCE OF MASONRY WEEPS AND OTHER WALL DRAINAGE

MECHANISMS. DO NOT COVER WEEPS, OR IMPEDE THE ABILITY

OF MOISTURE TO EXIT WALL SYSTEMS.

PREFINISHED 24 GA. GALV. STEEL REGLETED

COUNTERFLASHING. SECURE TO SUBSTRATE WITH

GASKETED FASTENERS 12-INCHES O.C., MIN. 2

FASTENERS.

SEALANT

CUT SIDING TO WALL

2" M

IN

1" M

IN

PREFINISHED 24 GA. GALV. STEEL PARAPET CAP.

TURN UP WALL 2-INCHES, MIN., INSTALL BUTYL TAPE

BEHIND TURN-UP, AND SECURE.

FULLY-ADHERED EPDM FLASHING MEMBRANE

COPING CAP TERMINATION

AT END WALLS

FOR USE WHERE PARAPET WALLS AND

RELATED COPING CAPS TERMINATE

INTO VERTICAL WALLS.

PREFINISHED 24 GA. GALV. STEEL REGLETED

COUNTERFLASHING. SECURE TO SUBSTRATE WITH

GASKETED FASTENERS 12-INCHES O.C., MIN. 2

FASTENERS.

SEALANT

CUT REGLET INTO WALL

2" M

IN

1" M

IN

PREFINISHED 24 GA. GALV. STEEL PARAPET CAP.

TURN UP WALL 2-INCHES, MIN., INSTALL BUTYL TAPE

BEHIND TURN-UP, AND SECURE.

FULLY-ADHERED EPDM FLASHING MEMBRANE

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR

CLARITY.

NOTE: MEMBRANE MUST BE EXTENDED TO CORNERS TO PROVIDE

COMPLETE COVERAGE OF THE WALL SURFACE.

COPING CAP JOINT PROFILE

SINGLE-LOCK STANDING SEAM; FOR USE WHERE

ADJACENT COPING CAPS ARE TO BE JOINED, BUTTON PUNCH.

1"

SEALANT - SEAL BOTH ENDS OF

STANDING SEAM

PARAPET WALL STEEL COPING CAP

BUTTON PUNCH

3" M

IN

2" M

IN

. O

R T

O M

AT

C

H

EX

IS

TI

N G

E

LE

VA

TI

O N

W H

IC

H

EV

ER

IS

G

R

EA

TE

R

3/4

5/8

7- 1/

IN

C H

M

AX

PREFINISHED 24 GA. GALV. STEEL COPING CAP.

HOOK OUTSIDE FACE TO CONTINUOUS CLEAT,

AND SECURE INNER FACE WITH GASKETED

FASTENERS APPROPRIATE FOR THE

SUBSTRATE ENCOUNTERED 18-INCHES O.C.

MAX., AND WITHIN 2-INCHES OF EACH END.

JOIN ADJACENT CAP SECTIONS USING 1-INCH

HIGH, SINGLE-LOCK STANDING SEAMS.

BUTTON PUNCH BOTH ENDS.

EXISTING STRUCTURAL DECK

SPECIFIED POLYISO. INSULATION

EPDM ROOFING MEMBRANE

REINFORCED PERIMETER FASTENING

STRIP WITH FACTORY-LAMINATED SEAM

TAPE. PRIME EPDM MEMBRANE PRIOR TO

APPLICATION TO REINFORCED FASTENING

STRIP.

EPDM FLASHING MEMBRANE, FULLY

ADHERED TO CURB

FASTENERS AND 2-INCH PLATES,

12-INCHES O.C. MAX.

COVER BOARD - 1/2-INCH THICK

3/4-INCH PLYWOOD MECHANICALLY ATTACHED TO

EXISTING WALL WITH PROPER SUBSTRATE FASTENERS;

TWO ROWS 24-INCHES O.C., STAGGERED

SPECIFIED UNDERLAYMENT - CONCRETE DECKS ONLY

22 GA. GALV. STEEL CONTINUOUS CLEAT. FABRICATE AS SHOWN TO

CREATE 1/2-INCH PER FOOT SLOPE TOWARD INNER FACE. SECURE

HORIZONTAL FLANGE AND VERTICAL FACE WITH RING SHANK COATED

NAILS 6-INCHES O.C. MAX.

EXTEND FULLY-ADHERED EPDM FLASHING MEMBRANE UP AND

OVER PARAPET WALL, AND DOWN OUTSIDE FASCIA. APPLY

SEALANT TO BACK SIDE OF FLASHING MEMBRANE, AND SECURE

12" O.C. MAX.

H

EI

G H

T

VA

R

IE

S;

-IN

C

H M

IN

IM

U M

NOMINAL 2-INCH THICK WOOD BLOCKING - WIDTH AS NECESSARY

TO MATCH EXISTING PARAPET WALL WIDTH. THICKNESS AS

NECESSARY TO ACHIEVE 4-INCH MINIMUM FLASHING HEIGHT.

SECURE TO SUBSTRATE 18-INCHES O.C. MAX. DECREASE

FASTENER SPACING TO 9-INCHES O.C. WITHIN 10-FEET OF A

BUILDING CORNER.

BUTYL

SEALANT - TYP

CLIENT

PROFESSIONAL

PROJECT

DESCRIPTIONDATE

ISSUE

Drawn By: PD

Checked By: SH

SHEET TITLE

File Name:

STAMP

SHEET 04 OF 05

ROOF PLAN

DETAILS 01-09

Testing Engineers & Consultants

1343 Rochester Road Troy, MI 48083

DETAIL 01 -

SCALE: NONE

ROOF CURB FLASHING DETAIL 02 -

SCALE: NONE

ROOF HATCH FLASHING DETAIL 03 -

SCALE: NONE

ROOF DRAIN FLASHING

DETAIL 04 -

SCALE: NONE

DETAIL 05 -

SCALE: NONE

DETAIL 06 -

SCALE: NONE

ROOF-TO-WALL FLASHING

DETAIL 07 -

SCALE: NONE

PARAPET WALL FLASHING DETAIL 08 -

SCALE: NONE

GUTTER EDGE FLASHING

DETAIL 09 -

SCALE: NONE

PARAPET WALL FLASHING

Detroit Public Schools

3011 W. Grand Blvd Detroit, MI 48202

PITCH PAN FLASHING TUBULAR PENETRATION FLASHING

75% Design Review Set03-25-2026

Davison Elementary-Middle School

2800 E. Davison Detroit, MI 48212

NOTE: DIS-CONNECTIONS AND RE-CONNECTIONS OF

ELECTRICAL, PLUMBING OR MECHANICAL

CONNECTIONS RELATED TO THE DISPLACEMENT

AND RE-INSTALLATION OF ROOFTOP UNITS SHALL

BE PERFORMED BY A CONTRACTOR LICENSED TO

PERFORM SUCH WORK. COORDINATE THIS

WORK WITH THE OWNER.

NOTE: AT ROOF CURB FLASHING HEIGHTS GREATER THAN 24-INCHES: PROVIDE

INTERMEDIATE SECUREMENT PER THE REQUIREMENTS AND RECOMMENDATIONS

OF THE EPDM ROOFING MEMBRANE MANUFACTURER.

4" M

IN

8" M

IN

PLAN VIEW OF CURB CAP

18 GA. STAINLESS STEEL CURB CAP WITH

WELDED SEAMS

PROVIDE DIAMOND CROSS-BREAK TO ELIMINATE

POTENTIAL FOR PONDING WATER ON CURB CAP.

FI

EL

D V

ER

IF

Y C

U R

B D

IM

EN

SI

O

N S)

FIELD VERIFY CURB DIMENSIONS)

SCALE: NONE

SLOPE SLOPE

SLO

PE

SLO

PE

WOOD BLOCKING - IF NECESSARY TO ACHIEVE 8-INCH MINIMUM

FLASHING HEIGHT. SECURE TO SUBSTRATE 18-INCHES O.C. AND WITHIN

2-INCHES OF EACH END.

CURB INSULATION - IF EXISTING CURB IS INSULATED, AND EXISTING INSULATION

CANNOT BE SALVAGED, PROVIDE CURB INSULATION TO MATCH EXISTING.

NOTE: SECURE TOP EDGE OF FLASHING WITH 1-INCH BY 1/8-INCH

ALUMINUM ANCHOR BAR SECURED 12-INCHES O.C. MAX. AND

WITHIN 2-INCHES OF EACH END. APPLY WATER CUT OFF

MASTIC TO THE BACKSIDE OF FLASHING PRIOR TO ANCHOR

BAR INSTALLATION. APPLY SEALANT TO TOP EDGE OF

FLASHING AND ANCHOR BAR AFTER COMPLETION OF WORK. IF

SUBSTRATE IS WOOD, NAILS AFFIXED WITH 1-INCH METAL

CAPS, 6-INCHES O.C. MAX., MAY BE USED IN LIEU OF

TERMINATION BAR.

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR CLARITY.

SPECIFIED POLYISOCYANURATE INSULATION

EXISTING STRUCTURAL DECK

COVER BOARD - 1/2-INCH THICK

EPDM ROOFING MEMBRANE

APPROX.

1/2"

EPDM FLASHING MEMBRANE, FULLY ADHERED TO CURB. REFER TO

NOTE REGARDING SECUREMENT OF FLASHING.

REINFORCED PERIMETER FASTENING STRIP WITH FACTORY-LAMINATED

SEAM TAPE. PRIME EPDM MEMBRANE PRIOR TO APPLICATION TO REINFORCED

FASTENING STRIP.

FASTENERS AND 2-INCH PLATES, 12-INCHES O.C. MAX.

NOTE: ALTERNATE FLASHING CONFIGURATIONS SHOWN ON ROOF CURB DETAIL SHEET

ARE ACCEPTABLE.

PROVIDE ADDITIONAL UNDERLYING

CURB CAP SUPPORT, IF NECESSARY

3/4-INCH PLYWOOD - SECURE TO

SUBSTRATE 18-INCHES O.C., MAX.

18 GA. GALVANIZED STEEL CURB CAP WITH

WELDED SEAMS. CROSSBREAK CAP TO PROVIDE

SLOPE ADEQUATE TO REMOVE STANDING WATER

FROM TOP OF CAP. SECURE VERTICAL FACE OF

CAP WITH GASKETED FASTENERS, 12-INCHES

O.C. MAX., AND WITHIN 2-INCHES OF EACH END.

FULLY-ADHERED EPDM MEMBRANE

2X4 WOOD BLOCKING/INSULATION STOP AT

PERIMETER OF CURB TOP. SECURE TO SUBSTRATE

18-INCHES O.C. AND WITHIN 2-INCHES OF EACH END.

1-1/2 INCH POLYISOCYANURATE INSULATION

4" M

IN

8" M

IN

2" M

IN

4" M

IN

M

AX

. H

EI

G H

T

PO

SS

IB

LE

1" M

IN

ALTERNATE COUNTERFLASHING NO. 1

FOR USE BELOW EXISTING METAL WALL SIDING WHERE 8-INCH

MINIMUM FLASHING HEIGHT CAN BE ACHIEVED.

ALTERNATE COUNTERFLASHING NO. 2

FOR USE BELOW EXISTING METAL WALL SIDING WHERE 8-INCH

MINIMUM FLASHING HEIGHT CANNOT BE ACHIEVED.

NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN

24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER

THE REQUIREMENTS AND RECOMMENDATIONS OF THE

EPDM ROOFING MEMBRANE MANUFACTURER.

NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS FOLLOWING

THE RECOMMENDATIONS AND REQUIREMENTS OF THE ROOFING

MEMBRANE MANUFACTURER. PROVIDE "T-JOINT COVERS" AT THE

BASE OF THE CURB AT FLASHING PIECE INTERSECTIONS.

NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND

COUNTERFLASHING, INSPECT EXISTING WALLS

FOR THE PRESENCE OF MASONRY WEEPS AND

OTHER WALL DRAINAGE MECHANISMS. DO NOT

COVER WEEPS, OR IMPEDE THE ABILITY OF

MOISTURE TO EXIT WALL SYSTEMS.

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR

CLARITY.

SPECIFIED POLYISOCYANURATE INSULATION

EXISTING STRUCTURAL DECK

EPDM ROOFING MEMBRANE

REINFORCED PERIMETER FASTENING

STRIP WITH FACTORY-LAMINATED SEAM

TAPE. PRIME EPDM MEMBRANE PRIOR TO

APPLICATION TO REINFORCED FASTENING

STRIP.

EPDM FLASHING MEMBRANE, FULLY

ADHERED TO CURB

FASTENERS AND 2-INCH PLATES,

12-INCHES O.C. MAX.

COVER BOARD - 1/2-INCH THICK

APPROX.

1/2"

3/4-INCH PLYWOOD MECHANICALLY ATTACHED TO EXISTING

WALL WITH PROPER SUBSTRATE FASTENERS - TWO ROWS

24-INCHES O.C., STAGGERED

SPECIFIED POLYISOCYANURATE INSULATION

EXISTING STRUCTURAL DECK

EPDM ROOFING MEMBRANE

REINFORCED PERIMETER FASTENING

STRIP WITH FACTORY-LAMINATED SEAM

TAPE. PRIME EPDM MEMBRANE PRIOR TO

APPLICATION TO REINFORCED FASTENING

STRIP.

EPDM FLASHING MEMBRANE, FULLY

ADHERED TO CURB

FASTENERS AND 2-INCH PLATES,

12-INCHES O.C. MAX.

COVER BOARD - 1/2-INCH THICK

APPROX.

1/2"

3/4-INCH PLYWOOD MECHANICALLY ATTACHED TO EXISTING

WALL WITH PROPER SUBSTRATE FASTENERS - TWO ROWS

24-INCHES O.C., STAGGERED

UNDERLAYMENTUNDERLAYMENT

PREFINISHED 24 GA. GALV. STEEL SLIP

COUNTERFLASHING. SECURE TO EXISTING

COUNTERFLASHING AS SHOWN USING GASKETED

FASTENERS 12-INCHES O.C. MAX., AND WITHIN

2-INCHES OF EACH END.

EXISTING COUNTERFLASHING

EXISTING METAL SIDING - DO NOT DISTURB.

PREFINISHED 24 GA. GALV. STEEL SLIP

COUNTERFLASHING. SECURE TO EXISTING

COUNTERFLASHING AS SHOWN USING GASKETED

FASTENERS 12-INCHES O.C. MAX., AND WITHIN

2-INCHES OF EACH END.

EXISTING COUNTERFLASHING - CUT AS SHOWN.

EXISTING METAL SIDING - DO NOT DISTURB.

SECURE TOP EDGE OF FLASHING USING AN ALUMINUM

TERMINATION BAR SECURED 12-INCHES O.C., MAX., AND

WITHIN 2-INCHES OF EACH END. PRIOR TO TERMINATION

BAR INSTALLATION, INSTALL MANUFACTURERS

RECOMMENDED SEALANT BEHIND FLASHING WHERE

TERMINATION BAR WILL BE PLACED. SEAL TOP EDGE OF

FLASHING AND TERMINATION BAR AFTER INSTALLATION.

SECURE TOP EDGE OF FLASHING USING AN ALUMINUM

TERMINATION BAR SECURED 12-INCHES O.C., MAX., AND

WITHIN 2-INCHES OF EACH END. PRIOR TO TERMINATION

BAR INSTALLATION, INSTALL MANUFACTURERS

RECOMMENDED SEALANT BEHIND FLASHING WHERE

TERMINATION BAR WILL BE PLACED. SEAL TOP EDGE OF

FLASHING AND TERMINATION BAR AFTER INSTALLATION.

22 GA. GALV. STEEL CONTINUOUS CLEAT.

FABRICATE WITH A 2-INCH FLANGE. SECURE

FLANGE AND VERTICAL FACE WITH RING SHANK

COATED NAILS 12-INCHES O.C. MAX. DECREASE

FASTENER SPACING TO 6-INCHES O.C. WITHIN

10-FEET OF A BUILDING CORNER.

2" M

IN

. O

R T

O M

AT

C

H

EX

IS

TI

N G

E

LE

VA

TI

O N

W H

IC

H

EV

ER

IS

G

R

EA

TE

R

3/4"

5/8"

7- 1/

2" M

AX

. F

AC

E

3/4-INCH PLYWOOD MECHANICALLY

ATTACHED TO EXISTING WALL WITH PROPER

SUBSTRATE FASTENERS - TWO ROWS

24-INCHES O.C., STAGGERED

SPECIFIED POLYISOCYANURATE INSULATION

EXISTING STRUCTURAL DECK

EPDM ROOFING MEMBRANE

REINFORCED PERIMETER FASTENING

STRIP WITH FACTORY-LAMINATED SEAM

TAPE. PRIME EPDM MEMBRANE PRIOR TO

APPLICATION TO REINFORCED FASTENING

STRIP.

EPDM FLASHING MEMBRANE, FULLY

ADHERED TO CURB

FASTENERS AND 2-INCH PLATES,

12-INCHES O.C. MAX.

COVER BOARD - 1/2-INCH THICK

APPROX.

1/2"

NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN

24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER THE

REQUIREMENTS AND RECOMMENDATIONS OF THE EPDM

ROOFING MEMBRANE MANUFACTURER.

NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS FOLLOWING

THE RECOMMENDATIONS AND REQUIREMENTS OF THE ROOFING

MEMBRANE MANUFACTURER. PROVIDE "T-JOINT COVERS" AT THE

BASE OF THE CURB AT FLASHING PIECE INTERSECTIONS.

NOTE: SECURE TOP EDGE OF FLASHING USING AN ALUMINUM

TERMINATION BAR SECURED 12-INCHES O.C., MAX., AND WITHIN

2-INCHES OF EACH END. PRIOR TO TERMINATION BAR

INSTALLATION, INSTALL MANUFACTURERS RECOMMENDED

SEALANT BEHIND FLASHING WHERE TERMINATION BAR WILL BE

PLACED. SEAL TOP EDGE OF FLASHING AND TERMINATION BAR

AFTER INSTALLATION.

NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND

COUNTERFLASHING, INSPECT EXISTING WALLS FOR THE

PRESENCE OF MASONRY WEEPS AND OTHER WALL DRAINAGE

MECHANISMS. DO NOT COVER WEEPS, OR IMPEDE THE ABILITY

OF MOISTURE TO EXIT WALL SYSTEMS.

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR

CLARITY.

4" FLANGE

1/2" HUG

PREFINISHED 24 GA. GALV. STEEL PERIMETER

EDGE FASCIA PIECE. FABRICATE WITH 1/2-INCH

HUG AT EDGE OF FLANGE AS SHOWN. SECURE

FLANGE WITH NAILS 3-INCHES O.C. MAX. IN TWO

STAGGERED ROWS. HOOK BOTTOM EDGE TO

CONTINUOUS CLEAT.

PRESSURE-SENSITIVE OUTER SEAM FLASHING - 9-INCH WIDTH. SEAL EDGES

AS SHOWN AFTER COMPLETION OF WORK.

PRESSURE-SENSITIVE OUTER SEAM FLASHING - 5-INCH OR 6-INCH WIDTH.

NOTE: AT A MINIMUM, PROVIDE AN ADDITIONAL 6" WIDE REINFORCEMENT

PIECE AT SHEET METAL FASCIA JOINTS. REFER TO ROOFING MEMBRANE

MANUFACTURER REQUIREMENTS FOR ADDITIONAL REQUIREMENTS AND

RECOMMENDATIONS AT SHEET METAL FASCIA JOINTS.

UNDERLAYMENT

EXISTING STRUCTURAL DECK

SPECIFIED POLYISOCYANURATE INSULATION

COVER BOARD - 1/2-INCH THICK

EPDM ROOFING MEMBRANE

SPECIFIED UNDERLAYMENT

2" M

IN

. O

R T

O M

AT

C

H

EX

IS

TI

N G

E

LE

VA

TI

O N

W H

IC

H

EV

ER

IS

G

R

EA

TE

R

7- 1/

2" M

AX

3/4

5/8

APPROX.

1/2"

NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN

24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER

THE REQUIREMENTS AND RECOMMENDATIONS OF THE

EPDM ROOFING MEMBRANE MANUFACTURER.

NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS FOLLOWING

THE RECOMMENDATIONS AND REQUIREMENTS OF THE ROOFING

MEMBRANE MANUFACTURER. PROVIDE "T-JOINT COVERS" AT THE

BASE OF THE CURB AT FLASHING PIECE INTERSECTIONS.

NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND

COUNTERFLASHING, INSPECT EXISTING WALLS FOR THE

PRESENCE OF MASONRY WEEPS AND OTHER WALL DRAINAGE

MECHANISMS. DO NOT COVER WEEPS, OR IMPEDE THE ABILITY

OF MOISTURE TO EXIT WALL SYSTEMS.

PREFINISHED 24 GA. GALV. STEEL COPING CAP. HOOK OUTSIDE

FACE TO CONTINUOUS CLEAT, AND SECURE INNER FACE WITH

GASKETED FASTENERS APPROPRIATE FOR THE SUBSTRATE

ENCOUNTERED 18-INCHES O.C. MAX., AND WITHIN 2-INCHES OF

EACH END. JOIN ADJACENT CAP SECTIONS USING 1-INCH HIGH

STANDING SEAMS.

22 GA. GALV. STEEL CONTINUOUS CLEAT. FABRICATE AS SHOWN TO

CREATE 1/2-INCH PER FOOT SLOPE TOWARD INNER FACE. SECURE

HORIZONTAL FLANGE AND VERTICAL FACE WITH RING SHANK COATED

NAILS 6-INCHES O.C. MAX.

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR

CLARITY.

SPECIFIED POLYISOCYANURATE INSULATION

EXISTING STRUCTURAL DECK

EPDM ROOFING MEMBRANE

REINFORCED PERIMETER FASTENING

STRIP WITH FACTORY-LAMINATED SEAM

TAPE. PRIME EPDM MEMBRANE PRIOR TO

APPLICATION TO REINFORCED FASTENING

STRIP.

EPDM FLASHING MEMBRANE, FULLY

ADHERED TO CURB

FASTENERS AND 2-INCH PLATES,

12-INCHES O.C. MAX.

EXTEND FULLY-ADHERED EPDM FLASHING MEMBRANE UP AND OVER

PARAPET WALL, AND DOWN OUTSIDE FASCIA. SECURE WITH ROOFING

NAILS AFFIXED WITH 1-INCH DIAMETER METAL CAPS 12" O.C. MAX.

COVER BOARD - 1/2-INCH THICK

UNDERLAYMENT

PREFINISHED 24 GA. GALV. STEEL PARAPET CAP.

TURN UP WALL 2-INCHES, MIN., INSTALL BUTYL TAPE

BEHIND TURN-UP, AND SECURE.

FULLY-ADHERED EPDM FLASHING MEMBRANE

COPING CAP TERMINATION

AT END WALLS

FOR USE WHERE PARAPET WALLS AND

RELATED COPING CAPS TERMINATE

INTO VERTICAL WALLS.

PREFINISHED 24 GA. GALV. STEEL REGLETED

COUNTERFLASHING. SECURE TO SUBSTRATE WITH

GASKETED FASTENERS 12-INCHES O.C., MIN. 2

FASTENERS.

SEALANT

CUT REGLET INTO WALL

2" M

IN

1" M

IN

1"

SEALANT - SEAL BOTH ENDS OF

STANDING SEAM

PARAPET WALL STEEL COPING CAP

BUTTON PUNCH

COPING CAP JOINT PROFILE

SINGLE-LOCK STANDING SEAM; FOR USE

WHERE ADJACENT COPING CAPS ARE TO BE

JOINED, BUTTON PUNCH.

FIELD VERIFY WALL WIDTH

H

EI

G H

T

VA

R

IE

S;

-IN

C

H M

IN

IM

U M

NOMINAL 2-INCH THICK WOOD BLOCKING - WIDTH AS NECESSARY

TO MATCH EXISTING PARAPET WALL WIDTH. THICKNESS AS

NECESSARY TO ACHIEVE 4-INCH MINIMUM FLASHING HEIGHT.

SECURE TO SUBSTRATE 18-INCHES O.C. MAX. DECREASE

FASTENER SPACING TO 9-INCHES O.C. WITHIN 10-FEET OF A

BUILDING CORNER.

3" M

IN

SELF-ADHERING MEMBRANE - LAP 4-INCHES OVER

UNDERLAYMENT

ASPHALT SHINGLES. SECURE EACH FULL-LENGTH

SHINGLE WITH SIX ROOFING NAILS.

EXISTING STRUCTURAL DECK

ASPHALT HIP SHINGLES. SECURE WITH ROOFING

NAILS. SEAL EXPOSED NAILS.

RIDGE FLASHING DETAIL

NOTE: DO NOT INSTALL ASPHALT SHINGLES CONFIGURED WITH RIDGE VENTS AT

HIPS. EXTEND SELF-ADHERING MEMBRANE OVER HIP (18-INCHES ON EACH SIDE

OF HIP, AND OVERLAP OVER UNDERLAYMENT 4-INCHES, MIN.).

18" MIN.BOTH SIDESOF RIDGE

4"

LAP

FASTERNERS TO PENETRATE

THROUGH ALL LAYERS OF ROOFING

MATERIAL AND INTO DECK

RIDGE SHINGLES

SEALING STRIPS

SELF-ADHERING

MEMBRANE. WRAP

OVER RIDGE

UNDERLAYMENT

SELF-ADHERING

MEMBRANE

ASPHALT SHINGLES

SELF-ADHERING MEMBRANE - LAP 4-INCHES OVER

UNDERLAYMENT

ASPHALT SHINGLES. SECURE EACH FULL-LENGTH

SHINGLE WITH SIX ROOFING NAILS.

EXISTING STRUCTURAL DECK

ASPHALT HIP SHINGLES. SECURE WITH ROOFING

NAILS. SEAL EXPOSED NAILS.

HIP FLASHING DETAIL

NOTE: DO NOT INSTALL ASPHALT SHINGLES CONFIGURED WITH RIDGE VENTS AT

HIPS. EXTEND SELF-ADHERING MEMBRANE OVER HIP (18-INCHES ON EACH SIDE

OF HIP, AND OVERLAP OVER UNDERLAYMENT 4-INCHES, MIN.).

18" MIN.

BOTH SIDES OF HIP 4"

LAP

UNDERLAYMENT

SELF-ADHERING MEMBRANE.

EXTEND UPSLOPE 24-INCHES MIN.,

BEYOND INTERIOR WALL OF THE

BUILDING ENVELOPE AS SHOWN.

EXTEND SELF-ADHERING MEMBRANE

OVER FLANGE OF PERIMETER EDGE

FASCIA METAL AS…

This is the start of the file's text. The full file is on GovTribe.