27-0001 Attachment A - Burton Drawings IFB.pdf
PDF 3 MB Posted
- Solicitation number
- RFP DET 260000002534 1
- Issued by
- Wayne County, Detroit City, Michigan
About this file
This is a set of architectural drawings and project specifications for a roof replacement project at Burton International Academy in Detroit, Michigan, prepared for Detroit Public Schools. The project encompasses approximately 96,080 square feet of roof replacement across nine distinct areas (A-I), with the majority of work (approximately 80,416 square feet in areas A-I) involving removal of existing built-up roofing (BUR) systems down to the structural deck and installation of a new fully-adhered 60-mil EPDM roofing membrane system. The proposed roof system includes a tapered polyisocyanurate insulation layer with a slope of 1/8-inch per foot starting at 1/2-inch thickness over a 2-1/2-inch base layer of polyisocyanurate insulation, a 1/2-inch high-density polyiso cover board, and complete flashing details for penetrations, curbs, drains, and wall transitions. Roof area F (approximately 15,664 square feet) on a gypsum concrete deck requires an asphalt-coated base sheet mechanically attached prior to the insulation and membrane installation. Acceptable manufacturers for the EPDM system include Carlisle, Johns Manville, and Elevate (Firestone), with an alternate price option available for a 20-year "Total System Warranty."
The drawings specify comprehensive work requirements including removal of existing roof systems, inspection and repair of structural decks and wood blocking, refastening of existing decks where necessary, and replacement of damaged components. The contractor is responsible for verifying all existing site conditions prior to proposal submission, including building dimensions, roof replacement area dimensions, drainage component locations, and existing roof system composition. Work includes temporary displacement and reinstallation of rooftop equipment, closure and sealing of abandoned openings, removal and replacement of roof hatches with new integrated curb and ladder safety posts, and management of existing gas and conduit lines. The project requires compliance with all applicable federal, state, and local codes and regulations, adherence to roofing system manufacturer specifications, and notification to the owner of any conflicts or discrepancies discovered during the work.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CLIENT
PROFESSIONAL
PROJECT
DESCRIPTIONDATE
ISSUE
Drawn By: PD
Checked By: SH
SHEET TITLE
File Name:
STAMP
SHEET 01 OF 06
TITLE SHEET
PROJECT LOCATION MAP
ROOF PLAN SYMBOL LEGEND:
ORD
INS
C
S SKYLIGHT CURB
CAPPED CURB
ROOF HATCH
ROOF CURB
SUPPORT CURBS
ROOF DRAIN
ROOF DRAIN WITH INSERT
OVERFLOW ROOF DRAIN
THROUGH-WALL SCUPPER
OVERFLOW ROOF SCUPPER
ORS
SANITARY VENT
TUBULAR PENETRATION
HOT STACK
PIPE CHASE BOX
PERIMETER OR CURBED EDGE
PARAPET WALL OR AREA DIVIDER
EXPANSION JOINT
GUTTER EDGE
PITCH PAN
ROOF-TO-WALL TRANSITION
AREA TRANSITION
SATELLITE DISH ON ROOF
WALKPADW
WALKWAY
SUPPLY OR CONDENSATE LINE
LADDER
SLOPE DIRECTION
RIDGE LINE
DUCT WORK
R RAISED EQUIPMENT
DOWNSPOUT SPLASHBLOCKSSUMP AREA
CHIMNEY
THROUGH-FASCIA SCUPPER
SCUPPER WITH CONDUCTOR BOX DETAIL NUMBER CALLOUT
SHEET NUMBER CALLOUT
SCOPE OF REPLACEMENT MAP
GENERAL NOTES:
1. DRAWINGS ARE PRODUCED AT ARCH D (24-INCH BY 36-INCH) SIZE.
PLEASE NOTE AND VERIFY THE SCALE INDICATED ON EACH DRAWING.
NOTE THAT ROOF PLANS AND OTHER PROJECT DRAWINGS PRODUCED
ON OTHER PAPER SIZES MAY NOT BE CORRECTLY SCALED.
2. ALL COMPONENTS SHOWN ON PROJECT DRAWINGS ARE NEW UNLESS
SPECIFICALLY INDICATED AS EXISTING.
3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY EXISTING
PROJECT SITE CONDITIONS. THESE CONDITIONS INCLUDE, BUT ARE NOT
LIMITED TO: BUILDING DIMENSIONS AND PROPOSED PROJECT STAGING
LOCATIONS, ROOF REPLACEMENT AREA DIMENSIONS, ROOF DRAINAGE
COMPONENT LOCATIONS, ROOF PENETRATION LOCATIONS, EXISTING
ROOF SYSTEM COMPONENT MAKE-UP AND THICKNESS, AND PROJECT
REPAIR QUANTITIES (IF APPLICABLE). THE CONTRACTOR SHALL VISIT
AND BECOME FAMILIAR WITH THE SITE AND BUILDING PRIOR TO
PROPOSAL SUBMISSION. INCLUDE THE COST OF ALL WORK DESCRIBED
IN THE BIDDING DOCUMENTS AND THAT IS REQUIRED OR REASONABLY
IMPLIED TO ACHIEVE THE DESIGN INTENT OF THE BIDDING DOCUMENTS.
NOTIFY THE ROOF CONSULTANT OF ANY CONFLICTS BETWEEN EXISTING
CONDITIONS AND THE NEW WORK, OF ANY OMISSIONS OR CONFLICTS IN
THE DRAWINGS AND ANY RESTRICTIONS RELATED TO THE EXECUTION
OF THE WORK INCLUDING THE COORDINATION WITH OTHER TRADES.
4. PRODUCTS PROPOSED FOR USE AND PROJECT WORK SHALL BE IN
ACCORDANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL
GOVERNING ORDINANCES, CODES AND REGULATIONS. NOTIFY THE
OWNER IMMEDIATELY OF CONFLICTS BETWEEN THE SPECIFIED
PRODUCTS AND/OR PROJECT WORK REQUIREMENTS AND CODES,
ORDINANCES AND/OR REGULATIONS.
5. IF DISCREPANCIES ARE DISCOVERED WITHIN THE PROJECT MANUAL OR
DRAWINGS; THE OWNER, NOT THE CONTRACTOR, SHALL DETERMINE
THE INTENT OF THE DESIGN AND PROVIDE CLARIFICATION. NO
ALLOWANCE SHALL BE MADE FOR CONTRACTOR MISINTERPRETATION
OR IMPLIED MISINTERPRETATION OF THE PROJECT MANUAL AND
DRAWINGS.
6. REFER TO THE PROJECT MANUAL AND ROOFING SYSTEM
MANUFACTURER WRITTEN INSTRUCTIONS FOR FURTHER CLARIFICATION
OF PROJECT REQUIREMENTS. NOTIFY THE OWNER IMMEDIATELY OF
CONFLICTS BETWEEN THE SPECIFIED DESIGN REQUIREMENTS AND THE
WRITTEN REQUIREMENTS AND RECOMMENDATIONS OF THE ROOFING
SYSTEM MANUFACTURER.
7. CLOSE AND SEAL ABANDONED OPENINGS TO MATCH EXISTING
ADJACENT SURFACES WHERE MECHANICAL, PLUMBING, AND/OR
ELECTRICAL ITEMS ARE REMOVED.
8. CONTRACTOR SHALL TAKE NORMAL PRECAUTIONS SO THAT DEBRIS,
ROOFING MATERIAL, ETC., DOES NOT FALL INTO THE BUILDING OR ON
EQUIPMENT PER SECTIONS 014000 AND 015000.
SUMMARY OF ROOF REPLACEMENT WORK - AREAS A-I
A. ASBESTOS LABORATORY ANALYSIS REPORT: REFER TO SECTION 022623 FOR
INFORMATION RELATING TO THE LOCATION OF ACM, IF APPLICABLE, WITHIN
PROJECT AREAS. IF POSITIVE, REFER TO SECTIONS 013543 AND 028233 FOR
PROCEDURES AND REQUIREMENTS RELATED TO THE REMOVAL AND DISPOSAL OF
NON-FRIABLE ASBESTOS RELATED TO THIS PROJECT.
B. ROOF REMOVAL AND SUBSTRATE PREPARATION: REMOVE EXISTING ROOF SYSTEM
DOWN TO THE STRUCTURAL DECK, INCLUDING ROOF MEMBRANE(S), AND
UNDERLYING INSULATION, UNDERLAYMENTS, AND ADDITIONAL ROOF MEMBRANES.
INSPECT THE EXISTING STRUCTURAL DECK, AND INFORM THE OWNER IMMEDIATELY
OF OBSERVED DAMAGE AND OR DETERIORATION. TEMPORARILY DISPLACE
ROOFTOP EQUIPMENT AS NECESSARY TO COMPLETE THE SPECIFIED WORK.
REFER TO SECTION 024100.
C. ROOF AREAS A, B, C, D, E, G, H & I: PROVIDE AN ALTERNATE PRICE FOR COMPLETE
REFASTENING OF EXISTING STRUCTURAL DECKS; PROVIDE A UNIT PRICE FOR
AREAS OF EXISTING STRUCTURAL DECK THAT REQUIRE REFASTENING. NOTE THAT
REFASTENING OF PERIMETER WOOD BLOCKING IS REQUIRED. REFER TO SECTION
053123 FOR RE-FASTENING REQUIREMENTS.
D. AFTER ROOF REMOVAL AND INSPECTION OF THE EXISTING STRUCTURAL DECK AND
PERIMETER WOOD BLOCKING, PERFORM REPAIRS TO THE STRUCTURAL DECK, AS
DETERMINED NECESSARY BY THE OWNER. REFER TO SECTIONS 030150 & 053123.
REPLACE DAMAGED OR DETERIORATED WOOD BLOCKING, AS DETERMINED
NECESSARY BY THE OWNER. REFER TO SECTION 061053.
E. PROVIDE REQUIRED WOOD BLOCKING WHERE INDICATED ON THE PROJECT
DRAWINGS. REFER TO SECTION 061053.
F. ROOF AREA F: PROVIDE AN UNDERLAYMENT CONSISTING OF AN ASPHALT-COATED
BASE SHEET, MECHANICALLY-ATTACHED TO THE EXISTING STRUCTURAL DECK AS
SPECIFIED IN SECTION 072215. REFER TO SECTION 072215 FOR PRODUCT AND
INSTALLATION REQUIREMENTS..
G. PROVIDE A TAPERED POLYISOCYANURATE INSULATION SYSTEM WITH AN
INSULATION SYSTEM SLOPE OF 1/8-INCH PER FOOT, AND A STARTING THICKNESS
OF 1/2-INCH OVER A BASE LAYER OF 2-1/2 INCH POLYISOCYANURATE INSULATION.
IF INDICATED ON THE PROJECT DRAWINGS, PROVIDE INSULATION SADDLES AND
CRICKETS WHERE SHOWN. REFER TO SECTION 072223 FOR ADDITIONAL
INSULATION PRODUCT AND INSTALLATION REQUIREMENTS.
H. PROVIDE A 1/2-INCH HIGH DENSITY POLYISO COVER BOARD OVER THE UNDERLYING
INSULATION. REFER TO SECTIONS 072221 & 072223 FOR ADDITIONAL PRODUCT AND
INSTALLATION REQUIREMENTS.
I. PROVIDE A FULLY-ADHERED, NOMINAL 60-MIL EPDM ROOF SYSTEM. AFTER
INSTALLATION OF SPECIFIED INSULATION AND COVER BOARD, INSTALL THE EPDM
ROOFING MEMBRANE IN BONDING ADHESIVE. PROVIDE EPDM AND SHEET METAL
FLASHINGS AS SPECIFIED. PROVIDE AN ALTERNATE PRICE FOR A 20-YEAR, “TOTAL
SYSTEM WARRANTY” FOR THE ROOF SYSTEM. REFER TO SECTIONS 075323 AND
076205 FOR PRODUCT AND INSTALLATION REQUIREMENTS.
1. ACCEPTABLE MANUFACTURERS:
a. CARLISLE
b. JOHNS MANVILLE
c. ELEVATE (FIRESTONE)
J. PROVIDE SEALANTS AT LOCATIONS INDICATED ON THE PROJECT DRAWINGS.
REFER TO SECTION 079201.
INDEX OF DRAWINGS:
SHEET 01 OF 06
SHEET 02 OF 06
SHEET 03 OF 06
SHEET 04 OF 06
SHEET 05 OF 06
SHEET 06 OF 06
TITLE SHEET
GENERAL INFORMATION SHEET 01 OF 01
ROOF PLAN - AREAS A-I
ROOF PLAN DETAILS 01-09
ROOF PLAN DETAILS 10-13
WALK PAD LAYOUT PLAN
XX
X
Testing Engineers & Consultants
1343 Rochester Road Troy, MI 48083
75% Design Review Set
Detroit Public Schools
3011 W. Grand Blvd Detroit, MI 48202
03-16-2026
Burton International Academy
2001 Martin Luther King Jr Blvd Detroit, MI 48208
CLIENT
PROFESSIONAL
PROJECT
DESCRIPTIONDATE
ISSUE
Drawn By: PD
Checked By: SH
SHEET TITLE
File Name:
STAMP
SHEET 02 OF 06
GENERAL
INFORMATION
SHEET 01 OF 01
Testing Engineers & Consultants
1343 Rochester Road Troy, MI 48083
EXISTING CONDITIONS:
NOTE: THE INFORMATION BELOW IS BASED ON RANDOM, LIMITED TEST CORES
MADE INTO THE ROOFING SYSTEM. CONDITIONS AT THE TEST CORE
LOCATIONS MAY NOT BE REPRESENTATIVE OF THE ENTIRE ROOF AREA.
IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
EXISTING ROOF SYSTEM COMPONENTS AND SLOPE.
ROOF AREAS A, B, C, D, E, G, H & I
· BUR AGGREGATE SURFACE
· 1/2-INCH PERLITE
· TAPERED POLYISO
· 2-INCH POLYISO
· STEEL DECK - NO SLOPE IN DECK
PROPOSED ROOF SYSTEMS:
NOTE: REFER TO SECTION 011000 - SUMMARY OF WORK, AND RELATED PROJECT
MANUAL SECTIONS FOR ADDITIONAL PRODUCT AND INSTALLATION
REQUIREMENTS FOR THE PROJECT.
Detroit Public Schools
3011 W. Grand Blvd Detroit, MI 48202
RECOMMENDED MAXIMUM L:W RATIOS FOR SADDLES AND CRICKETS
ROOF SLOPE SADDLE MATERIAL
SLOPE L:W RATIO
1/8 1/4 2:1
1/4 1/2 3:1
1/2 1 4:1
L
W
CRICKET DRAIN SUMP AREA
SADDLE
ROOF CURB
CRICKETS MUST BE USED ON THE UPHILL SLOPE OF
ANY CURB THAT IS GREATER THAN 24-INCHES
L
W
PROPOSED ROOF SYSTEM - ROOF AREAS A, B, C, D, E, G, H & I (APPROX. 80,416 SF.):
· FULLY-ADHERED 60-MIL EPDM WITH 6-INCH SEAMS
· 1/2-INCH HIGH DENSITY POLYISO COVERBOARD - ADHERED AS SPECIFIED
· 1/8-INCH PER FOOT TAPERED POLYISOCYANURATE INSULATION WITH 1/2-INCH
STARTING THICKNESS - ADHERED AS SPECIFIED
· 2-1/2 INCH POLYISOCYANURATE INSULATION - ADHERED AS SPECIFIED
· EXISTING STEEL DECK - NO SLOPE IN DECK
COVER BOARD, INSULATION & UNDERLAYMENT ATTACHMENT
REQUIREMENTS:
75% Design Review Set03-16-2026
Burton International Academy
2001 Martin Luther King Jr Blvd Detroit, MI 48208
FIELD OF ROOF PERIMETERS CORNERS
COVER BOARD
TOP AND INTERMEDIATE
INSULATION LAYER(S)
BOTTOM INSULATION
LAYER
ADHERED IN TWO-PART
URETHANE FOAM
ADHESIVE 3/4" BEADS
12" O.C.
ADHERED IN TWO-PART
URETHANE FOAM
ADHESIVE 3/4" BEADS
6" O.C.
MECH. ATTACH WITH 12
FASTENERS PER 4' X 8'
BOARD (ONE FASTENER
PER 2.67 SF).
MECH. ATTACH WITH 24
FASTENERS PER 4' X 8'
BOARD (ONE FASTENER
PER 1.33 SF).
LOOSE-LAID
LOOSE-LAID
MECH. ATTACH WITH 32
FASTENERS PER 4' X 8'
BOARD (ONE FASTENER
PER 1.00 SF).
ADHERED IN TWO-PART
URETHANE FOAM
ADHESIVE 3/4" BEADS
12" O.C.
ADHERED IN TWO-PART
URETHANE FOAM
ADHESIVE 3/4" BEADS
6" O.C.
ATTACHMENT FOR
STEEL DECKS
PROJECT SPECIFIC KEY NOTES:
PROVIDE TAPERED DRAINAGE SUMPS AT ROOF DRAIN LOCATIONS INDICATED ON THE ROOF
PLAN. REFER TO DETAIL 04 AND SECTIONS 072221 & 072223 FOR PRODUCT AND INSTALLATION
REQUIREMENTS.
INSTALL NEW INSULATION SADDLES BETWEEN ROOF DRAINS, AND AT OTHER LOCATIONS
INDICATED ON THE ROOF PLAN - REFER TO SECTIONS 072221 & 072223 FOR PRODUCT AND
INSTALLATION REQUIREMENTS. ADJUST SADDLE CONFIGURATION BASED ON FIELD
CONDITIONS OBSERVED.
CONTRACTOR TO RAISE CURBS AS NEEDED TO ACHIEVE A MINIMUM FLASHING HEIGHT OF
8-INCHES - RAISE ALL ELECTRICAL, PLUMBING AND MECHANICAL AS NEEDED - ALL WORK IS TO
BE PERFORMED BY LICENSED PROFESSIONAL TO PERFORM SUCH WORK.
EXISTING ROOF HATCH - CONTRACTOR SHALL REMOVE AND DISPOSE OF EXISTING ROOF
HATCH & CURB - PROVIDE ALL NEW ROOF HATCH WITH INTEGRATED CURB AND LADDER-UP
SAFETY POST - REFER TO SECTION 024100 FOR PRODUCT REQUIREMENTS.
EXISTING GAS & CONDUIT LINES ON ROOF - TEMPORARILY DISPLACE TO ALLOW FOR
INSTALLATION OF NEW ROOF SYSTEM. PROVIDE NEW CONNECTIONS WHERE EXISTING IS
DETERIORATED - ADD NEW WHERE MISSING OR AS NEEDED FOR PROPER COMPLETE
REINSTALLATION. RE-INSTALL ON NEW PREFABRICATED SUPPORTS AND SET ON NEW
WALKPADS. NOTE THAT DISCONNECTION AND RECONNECTION OF GAS AND CONDUIT LINES
SHALL BE PERFORMED BY A CONTRACTOR LICENSED TO PERFORM THE SPECIFIED WORK.
ABANDONED PENETRATIONS - CONTRACTOR SHALLREMOVE AND DISPOSE OF ANBANNONED
PENETRATIONS - REPAIR DECK AS NECESSARY - REFER TO SECTIONS 035116 & 053123 FOR
DECK REPAIR REQUIREMENTS.
WHERE 8-INCH FLASHING HEIGHTS CANNOT BE ARCHIVED CONTRACTOR SHALL SEAL TO
EDGE OF FLASHING WITH MEMBRANE MANUFACTURERS LIQUID APPLIED FLASHING SYSTEM
A
B
C
D
E
F
G
ROOF AREA F
· BUR AGGREGATE SURFACE
· 1/2-INCH PERLITE
· 2-INCH POLYISO
· 2-INCH POLYISO
· BASE SHEET
· GYPSUM DECK - 1/8-INCH PER FOOT SLOPE IN DECK
PROPOSED ROOF SYSTEM - ROOF AREA F (APPROX. 15,664 SF.):
· FULLY-ADHERED 60-MIL EPDM WITH 6-INCH SEAMS
· 1/2-INCH HIGH DENSITY POLYISO COVERBOARD - ADHERED AS SPECIFIED
· 1/8-INCH PER FOOT TAPERED POLYISOCYANURATE INSULATION WITH 1/2-INCH
STARTING THICKNESS - ADHERED AS SPECIFIED
· 2-1/2 INCH POLYISOCYANURATE INSULATION - ADHERED AS SPECIFIED
· BASE SHEET - MECHANICALLY-ATTACHED
· EXISTING GYPSUM DECK - 1/8-INCH PER FOOT SLOPE IN DECK
ATTACHMENT FOR
GYPSUM CONCRETE
DECKS
FIELD OF ROOF PERIMETERS CORNERS
COVER BOARD ADHERED IN TWO-PART
URETHANE FOAM
ADHESIVE 3/4" BEADS
12" O.C.
UNDERLAYMENT
ADHERED IN TWO-PART
URETHANE FOAM
ADHESIVE 3/4" BEADS
6" O.C.
ADHERED IN TWO-PART
URETHANE FOAM
ADHESIVE 3/4" BEADS
4" O.C.
ADHERED IN TWO-PART
URETHANE FOAM
ADHESIVE 3/4" BEADS
12" O.C.
ADHERED IN TWO-PART
URETHANE FOAM
ADHESIVE 3/4" BEADS
6" O.C.
ADHERED IN TWO-PART
URETHANE FOAM
ADHESIVE 3/4" BEADS
4" O.C.
ADHERED IN TWO-PART
URETHANE FOAM
ADHESIVE 3/4" BEADS
12" O.C.
ADHERED IN TWO-PART
URETHANE FOAM
ADHESIVE 3/4" BEADS
6" O.C.
ADHERED IN TWO-PART
URETHANE FOAM
ADHESIVE 3/4" BEADS
4" O.C.
TOP INSULATION
LAYER
BOTTOM AND
INTERMEDIATE
INSULATION LAYER(S)
FASTEN 9" O.C. AT LAPS
AND 18" O.C. IN TWO
EQUALLY SPACED,
STAGGERED ROWS
BETWEEN LAPS.
FASTEN 6" O.C. AT LAPS
AND 9" O.C. IN TWO
EQUALLY SPACED,
STAGGERED ROWS
BETWEEN LAPS.
FASTEN 7" O.C. AT LAPS
AND 7" O.C. IN THREE
EQUALLY SPACED,
STAGGERED ROWS
BETWEEN LAPS.
R
R
R
ROOF PLAN - AREAS A-I
CLIENT
PROFESSIONAL
PROJECT
DESCRIPTIONDATE
ISSUE
Drawn By: PD
Checked By: SH
SHEET TITLE
File Name:
STAMP
SHEET 03 OF 06
ROOF PLAN
AREAS A-I
Testing Engineers & Consultants
1343 Rochester Road Troy, MI 48083
Detroit Public Schools
3011 W. Grand Blvd Detroit, MI 48202
169'
159'
45'
96'
106'
82'
68'
106'
81'
60'
60'
206'
14' 2"
30'
76'
45'15'26'
216'
13'
74'
39'
62'
89'
28'
32'
100'
45'
10"
20'
TYP.
04TYP.
04 07
04TYP.
04TYP.
04TYP.
04TYP.
04TYP.
TYP. 3
SIDES
04TYP.
04TYP.
04TYP.
04 TYP.
TYP. 4
SIDES 08
04 TYP.
04 TYP.
04TYP.
TYP. 4
SIDES
TYP. 4
SIDES
75% Design Review Set03-16-2026
Burton International Academy
2001 Martin Luther King Jr Blvd Detroit, MI 48208
ATYP.
ATYP.
ATYP.
ATYP.
BTYP.
BTYP.
BTYP.
CTYP.
CTYP.
CTYP.
CTYP.
D
D
ETYP. ETYP.
ETYP.
F F
04 TYP.
04TYP.ROOF AREA A
22,551 SF.
ROOF AREA B
4,320 SF.
ROOF AREA C
8,703 SF.
ROOF AREA D
3,600SF.
ROOF AREA F
15,664 SF.
ROOF AREA E
4,860 SF.
ROOF AREA G
20,212 SF.
ROOF AREA H
8,962 SF.
ROOF AREA I
7,208 SF.
G
G
G
G
G
G
4' OVERHANG
ROOF AREA H MOVED
FOR CLARITY
ROOF AREA I MOVED
FOR CLARITY
WOOD BLOCKING - IF NECESSARY TO ACHIEVE
8-INCH MINIMUM FLASHING HEIGHT. SECURE TO
SUBSTRATE 18-INCHES O.C. AND WITHIN 2-INCHES
OF EACH END.
EXISTING ROOFTOP UNIT - TEMPORARILY DISPLACE
TO ALLOW FOR INSTALLATION OF NEW ROOF
SYSTEM AND RELATED FLASHING COMPONENTS.
REINSTALL TO ORIGINAL POSITION AFTER
COMPLETION OF WORK. RE-SECURE TO EXISTING
CURB WITH GASKETED FASTENERS 12-INCHES O.C.
MAX., AND WITHIN 2-INCHES OF EACH CORNER.
CURB INSULATION - IF EXISTING
CURB IS INSULATED, AND
EXISTING INSULATION CANNOT BE
SALVAGED, PROVIDE CURB
INSULATION TO MATCH EXISTING.
PREFINISHED 24 GA. GALV. STEEL
SURFACE-MOUNTED
COUNTERFLASHING. SECURE TO
EXISTING CURB COUNTERFLASHING
AS SHOWN USING GASKETED
FASTENERS 12-INCHES O.C. MAX.,
AND WITHIN 2-INCHES OF EACH END.
SELF-ADHERING MEMBRANE
COMPATIBLE WITH EXISTING
SUBSTRATE(S)
REFER TO DETAILS BELOW FOR
FLASHING REQUIREMENTS.
ALT. COUNTERFLASHING NO. 2
FOR USE WHERE APPROVED AND WHERE
EXISTING CURB IS SEPARATED FROM THE
EXISTING ROOFTOP PENETRATION
BUTYL TAPE - INSTALL BEHIND
COUNTERFLASHING
SEALANT
NOTE: SECURE TOP EDGE OF FLASHING USING AN
ALUMINUM TERMINATION BAR SECURED
12-INCHES O.C., MAX., AND WITHIN
2-INCHES OF EACH END. PRIOR TO
TERMINATION BAR INSTALLATION, INSTALL
MANUFACTURERS RECOMMENDED
SEALANT BEHIND FLASHING WHERE
TERMINATION BAR WILL BE PLACED. SEAL
TOP EDGE OF FLASHING AND TERMINATION
BAR AFTER INSTALLATION.
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING
CORNERS FOLLOWING THE
RECOMMENDATIONS AND REQUIREMENTS
OF THE ROOFING MEMBRANE
MANUFACTURER. PROVIDE "T-JOINT
COVERS" AT THE BASE OF THE CURB AT
FLASHING PIECE INTERSECTIONS.
ALT. VERTICAL MEMBRANE TERMINATION
FOR USE WHERE HORIZONTAL TERMINATION OF
EPDM MEMBRANE IS NOT POSSIBLE
4" M
IN
4" M
IN
8" M
IN
FL
AS
H
IN
G H
EI
G
H T
NOTE: DIS-CONNECTIONS AND RE-CONNECTIONS
OF ELECTRICAL, PLUMBING OR
MECHANICAL CONNECTIONS RELATED TO
THE DISPLACEMENT AND RE-INSTALLATION
OF ROOFTOP UNITS SHALL BE PERFORMED
BY A CONTRACTOR LICENSED TO PERFORM
SUCH WORK. COORDINATE THIS WORK
WITH THE OWNER.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT
SHOWN FOR CLARITY.
EXISTING STRUCTURAL DECK
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING STRIP WITH
FACTORY-LAMINATED SEAM TAPE. PRIME EPDM
MEMBRANE PRIOR TO APPLICATION TO REINFORCED
FASTENING STRIP.
FASTENERS AND 2-INCH PLATES, 6-INCHES O.C. MAX.
EPDM MEMBRANE, 8" MIN. HEIGHT, FULLY
ADHERED TO CURB. REFER TO NOTE
REGARDING SECUREMENT OF MEMBRANE.
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING STRIP WITH
FACTORY-LAMINATED SEAM TAPE. PRIME EPDM
MEMBRANE PRIOR TO APPLICATION TO REINFORCED
FASTENING STRIP.
BATTEN STRIP OR FASTENERS AND 2-INCH PLATES,
12-INCHES O.C. MAX.
1-1/4" 1/2"
APPR
O
X.
2-3/4"
EPDM MEMBRANE, FULLY ADHERED TO CURB. 8" MIN.
HEIGHT, REFER TO NOTE REGARDING SECUREMENT
OF FLASHING.
APPROX.
1/2"
ALT. VERTICAL TERMINATION -
TWO PIECE FLASHING
FOR USE WHERE HORIZONTAL TERMINATION OF
EPDM MEMBRANE IS NOT POSSIBLE
APPROX.
1/2"
EPDM ROOFING MEMBRANE
SEAM TAPE - 6-INCH WIDTH. APPLY PRIMER TO
UNDERLYING EPDM ROOF MEMBRANE AND OVERLYING
EPDM FLASHING MEMBRANE PRIOR TO APPLICATION.
1-1/4" 1/2"
2-3/4"
2"
PRESSURE-SENSITIVE OUTERSEAM FLASHING;
MINIMUM 5-INCH WIDTH. SEAL EDGES AS SHOWN.
EPDM ROOFING MEMBRANE
SEAM TAPE - 6-INCH WIDTH. APPLY PRIMER
TO UNDERLYING EPDM ROOF MEMBRANE
AND OVERLYING EPDM FLASHING
MEMBRANE PRIOR TO APPLICATION.
BATTEN STRIP OR FASTENERS AND 2-INCH
PLATES, 12-INCHES O.C. MAX.
PRESSURE-SENSITIVE OUTERSEAM
FLASHING; MIN. 5-INCH WIDTH. SEAL
EDGES AS SHOWN.
4" M
IN
WRAP EPDM MEMBRANE FLASHING OVER
THE TOP OF THE CURB AND SECURE TO
THE INSIDE OF THE CURB WITH 1" METAL
CAP NAILS AT 6" O.C. MAXIMUM.
MEMBRANE SECUREMENT
ALT. TWO-PIECE FLASHING
PREFINISHED 24 GA. GALV.
STEEL SLIP COUNTERFLASHING.
SECURE TO EXISTING CURB
COUNTERFLASHING AS SHOWN
USING GASKETED FASTENERS
12-INCHES O.C. MAX., AND
WITHIN 2-INCHES OF EACH END.
EXISTING ROOFTOP UNIT
COUNTERFLASIHNG
REFER TO DETAILS BELOW FOR
FLASHING REQUIREMENTS.
ALT. COUNTERFLASHING NO. 1
FOR USE WHERE APPROVED AND WHERE EXISTING
ROOFTOP UNIT CANNOT BE DISPLACED TO ALLOW FOR
FLASHING, OR WHERE GAP BETWEEN EXISTING
ROOFTOP UNIT COUNTERFLASHING AND CURB IS TOO
NARROW TO ACCOMMODATE FLASHING
4" M
IN
8" M
IN
FL
AS
H
IN
G H
EI
G
H T
EXIST. ROOFTOP PENETRATION
EPDM FLASHING, 8" MIN. HEIGHT, FULLY
ADHERED TO CURB. REFER TO NOTE
REGARDING SECUREMENT OF MEMBRANE.
ALT. NOTE:
ALT. SECUREMENT
SPECIFIED POLYISO. INSULATION
UNDERLAYMENT - GYPSUM DECKS ONLY
APPR
O
X.
8" M
IN
IM
U M
H
EI
G H
T
NOTE: DIS-CONNECTIONS AND RE-CONNECTIONS OF ELECTRICAL,
PLUMBING OR MECHANICAL COMPONENTS RELATED TO
THE DISPLACEMENT AND RE-INSTALLATION OF ROOFTOP
UNITS SHALL BE PERFORMED BY A CONTRACTOR LICENSED
TO PERFORM SUCH WORK. COORDINATE THIS WORK WITH
THE OWNER.
NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN
24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER
THE REQUIREMENTS AND RECOMMENDATIONS OF THE
EPDM ROOFING MEMBRANE MANUFACTURER.
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS
FOLLOWING THE RECOMMENDATIONS AND REQUIREMENTS
OF THE ROOFING MEMBRANE MANUFACTURER. PROVIDE
"T-JOINT COVERS" AT THE BASE OF THE CURB AT FLASHING
PIECE INTERSECTIONS.
NOTE: APPLY WATER CUT OFF MASTIC TO THE BACKSIDE OF
FLASHING PRIOR TO COUNTERFLASIHNG INSTALLATION.
USE COUNTERFLASHING AS SECUREMENT PIECE FOR
FLASHING AS SHOWN.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
APPROX.
1/2"
EPDM FLASHING MEMBRANE, FULLY ADHERED TO CURB. REFER TO
NOTE REGARDING SECUREMENT OF FLASHING.
REINFORCED PERIMETER FASTENING STRIP WITH FACTORY-LAMINATED
SEAM TAPE. PRIME EPDM MEMBRANE PRIOR TO APPLICATION TO REINFORCED
FASTENING STRIP.
FASTENERS AND 2-INCH PLATES, 12-INCHES O.C. MAX.
UNDERLAYMENT - GYPSUM DECKS ONLY
NEW ROOF HATCH ON CURB -
RAISE TO ACCOMMODATE NEW
ROOF SYSTEM ELEVATION, AND
RE-SECURE FLANGE TO WOOD
BLOCKING AS SHOWN. PROVIDE
INTERIOR FINISH REPAIRS AS
NEEDED TO ACCOMMODATE
RAISING OF CURB.
NOMINAL WOOD BLOCKING.
THICKNESS TO MATCH EXISTING
COVER BOARD AND INSULATION
THICKNESS; WIDTH GREATER
THAN ROOF HATCH CURB AND
CURB FLANGE. SECURE TO
SUBSTRATE 18-INCHES O.C.
WITH SPECIFIED FASTENERS
APPROPRIATE FOR THE
SUBSTRATE ENCOUNTERED.
PREFINISHED 24 GA. GALV.
STEEL SLIP COUNTERFLASHING.
SECURE TO EXISTING CURB
COUNTERFLASHING AS SHOWN
USING GASKETED FASTENERS
12-INCHES O.C. MAX., AND
WITHIN 2-INCHES OF EACH END.
APPLY SEALANT TO BACKSIDE
OF COUNTERFLASHING PRIOR
TO INSTALLATION.
NEW SAFETY POST.
NOTE: DIS-CONNECTIONS AND RE-CONNECTIONS OF ELECTRICAL,
PLUMBING OR MECHANICAL COMPONENTS RELATED TO
THE DISPLACEMENT AND RE-INSTALLATION OF ROOFTOP
UNITS SHALL BE PERFORMED BY A CONTRACTOR LICENSED
TO PERFORM SUCH WORK. COORDINATE THIS WORK WITH
THE OWNER.
4" M
IN
8" M
IN
IM
U M
H
EI
G H
T
NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN
24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER
THE REQUIREMENTS AND RECOMMENDATIONS OF THE
EPDM ROOFING MEMBRANE MANUFACTURER.
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS
FOLLOWING THE RECOMMENDATIONS AND REQUIREMENTS
OF THE ROOFING MEMBRANE MANUFACTURER. PROVIDE
"T-JOINT COVERS" AT THE BASE OF THE CURB AT FLASHING
PIECE INTERSECTIONS.
NOTE: SECURE TOP EDGE OF FLASHING WITH 1-INCH BY 1/8-INCH
ALUMINUM ANCHOR BAR SECURED 12-INCHES O.C. MAX.
AND WITHIN 2-INCHES OF EACH END. APPLY WATER CUT
OFF MASTIC TO THE BACKSIDE OF FLASHING PRIOR TO
ANCHOR BAR INSTALLATION. APPLY SEALANT TO TOP
EDGE OF FLASHING AND ANCHOR BAR AFTER COMPLETION
OF WORK. IF SUBSTRATE IS WOOD, NAILS AFFIXED WITH
1-INCH METAL CAPS, 6-INCHES O.C. MAX., MAY BE USED IN
LIEU OF TERMINATION BAR.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
EPDM FLASHING MEMBRANE, FULLY ADHERED TO CURB. REFER TO
NOTE REGARDING SECUREMENT OF FLASHING.
REINFORCED PERIMETER FASTENING STRIP WITH FACTORY-LAMINATED
SEAM TAPE. PRIME EPDM MEMBRANE PRIOR TO APPLICATION TO REINFORCED
FASTENING STRIP.
FASTENERS AND 2-INCH PLATES, 12-INCHES O.C. MAX.
APPROX.
1/2"
APPROX.
1/2"
EPDM ROOFING MEMBRANE
SEAM TAPE - 6-INCH WIDTH. APPLY PRIMER
TO UNDERLYING EPDM ROOF MEMBRANE
AND OVERLYING EPDM FLASHING
MEMBRANE PRIOR TO APPLICATION.
2"
PRESSURE-SENSITIVE OUTERSEAM
FLASHING; MINIMUM 5-INCH WIDTH.
SEAL EDGES AS SHOWN.
ALT. TWO-PIECE FLASHING
EPDM FLASHING, 8" MIN. HEIGHT,
FULLY ADHERED TO CURB. REFER
TO NOTE REGARDING SECUREMENT
OF MEMBRANE.
ALT. VERTICAL MEMBRANE TERMINATION
FOR USE WHERE HORIZONTAL TERMINATION OF
EPDM MEMBRANE IS NOT POSSIBLE
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING STRIP WITH
FACTORY-LAMINATED SEAM TAPE. PRIME EPDM
MEMBRANE PRIOR TO APPLICATION TO REINFORCED
FASTENING STRIP.
BATTEN STRIP OR FASTENERS AND 2-INCH PLATES,
12-INCHES O.C. MAX.
1-1/4" 1/2"
APPR
O
X.
2-3/4"
EPDM MEMBRANE, FULLY ADHERED TO CURB. 8" MIN.
HEIGHT, REFER TO NOTE REGARDING SECUREMENT
OF FLASHING.
ALT. VERTICAL TERMINATION -
TWO PIECE FLASHING
FOR USE WHERE HORIZONTAL TERMINATION OF
EPDM MEMBRANE IS NOT POSSIBLE
1-1/4" 1/2"
APPR
O
X.
2-3/4"
EPDM ROOFING MEMBRANE
SEAM TAPE - 6-INCH WIDTH. APPLY PRIMER TO
UNDERLYING EPDM ROOF MEMBRANE AND
OVERLYING EPDM FLASHING MEMBRANE PRIOR
TO APPLICATION.
BATTEN STRIP OR FASTENERS AND 2-INCH
PLATES, 12-INCHES O.C. MAX.
PRESSURE-SENSITIVE OUTERSEAM
FLASHING; MIN. 5-INCH WIDTH. SEAL
EDGES AS SHOWN.
TWO PIECE- PREFINISHED 24 GA. GALV. STEEL
CURB CAP. SECURE VERTICAL FACE OF CAP
WITH GASKETED FASTENERS, 12-INCHES O.C.
MAX., AND WITHIN 2-INCHES OF EACH END.
EXISTING UNIT ON CURB SUPPORTS.
TEMPORARILY DISPLACE TO ALLOW FOR
INSTALLATION OF NEW ROOF SYSTEM AND
RELATED FLASHING. REINSTALL ON NEW SHEET
METAL CAP AFTER COMPLETION OF WORK.
UNDERLAYMENT - GYPSUM DECKS ONLY
EXISTING SUPPORT CURB
EXISTING WOOD BLOCKING TO MATCH SUPPORT
CURB LENGTH AND WIDTH
LCC
PLAN VIEW OF ROOF SUMP AREA
SCALE: NONE
TAPERED INSULATION/EDGE STRIPS AS NEEDED
TO RESULT IN 8'-0" X 8'-0" SUMP AREA
ROOF DRAIN
NOTE: EXTEND EPDM ROOFING MEMBRANE UNDER CLAMPING
RING AND INTO THE ROOF DRAIN. TIGHTLY SECURE
CLAMPING RING AFTER INSTALLATION OF ROOF DRAIN
FLASHING COMPONENTS.
CUT DRAINAGE HOLE IN MEMBRANE MIN. 1/2" GREATER
THAN DRAIN PIPE DIAM. ON ALL SIDES
EXTEND MEMBRANE 1" MIN.
BEYOND CLAMPING RING
IN
ST
AL
L
TA
PE
R
ED
P O
LY
IS
O C
YA
N
U R
AT
E
IN
SU
LA
TI
O N
A N
D /O
R T
AP
ER
ED
E
D G
E
ST
R
IP
T O
R
ES
U
LT
IN
' x
' S U
M P
AR
EA
(T
YP
APPROX. 4'-0" - REFER TO NOTE ABOVE REGARDING ROOF SUMP AREA
CONSTRUCTION AND SLOPE REQUIREMENTS
IN
ST
AL
L
TA
PE
R
ED
P O
LY
IS
O C
YA
N
U R
AT
E
IN
SU
LA
TI
O N
A N
D /O
R T
AP
ER
ED
E
D G
E
ST
R
IP
T O
R
ES
U
LT
IN
' x
' S U
M P
AR
EA
(T
YP
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
EXISTING STRUCTURAL DECK
SPECIFIED POLYISOCYANURATE INSULATION
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
TAPERED POLYISOCYANURATE INSULATION, AND/OR
TAPERED EDGE STRIP(S) AS NECESSARY TO RESULT IN A
8-FOOT BY 8-FOOT MINIMUM TAPERED ROOF DRAIN SUMP
AREA WITH A MINIMUM SLOPE OF 1/4-INCH PER FOOT.
EXISTING ROOF DRAIN ASSEMBLY. CLEAN BOWL FREE OF ALL
EXISTING FLASHING MATERIALS AND BITUMINOUS RESIDUE PRIOR
TO INSTALLATION OF EPDM ROOFING MEMBRANE AND
MANUFACTURER'S RECOMMENDED SEALANT. INSPECT DRAIN
BOWL, CLAMPING RING, AND OTHER ASSEMBLY COMPONENTS FOR
DAMAGE. REPLACE DAMAGED COMPONENTS AS NECESSARY PER
SECTION 024100.
EXISTING ROOF DRAIN STRAINER. REMOVE AND DISCARD
DAMAGED, BROKEN OR PLASTIC-TYPE STRAINER(S).
REPLACE DISCARDED STRAINERS WITH CAST IRON
STRAINERS. REFER TO SECTION 024100.
NOTE: EXTEND EPDM ROOFING MEMBRANE UNDER CLAMPING
RING AND INTO THE ROOF DRAIN. TIGHTLY SECURE
CLAMPING RING AFTER INSTALLATION OF ROOF DRAIN
FLASHING COMPONENTS.
MANUFACTURER'S RECOMMENDED SEALANT. INSTALL ONE TUBE,
MINIMUM, UNDER EPDM ROOFING MEMBRANE AT CLAMPING RING,
CONTINUOUS BEAD - TO ROOF DRAIN ASSEMBLY INTERSECTION.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
NOTE: IF FIELD SEAM EDGE IS WITHIN 9" OF DRAIN COMPRESSION
RING, EPDM TARGET PATCH REQUIRED.
UNDERLAYMENT - GYPSUM DECKS ONLY
CL
NOTE: PRIOR TO SOLDERING OF STAINLESS STEEL, CLEAN WORK AREA USING SOLVENTS
AND WIRE BRUSH; REMOVING DIRT, OIL, GREASE, AND OTHER CONTAMINANTS FROM
THE WORK AREA. TIN THE WORK AREA BY APPLYING ACID (FLUX). PERFORM
SOLDERING WORK. AFTER COMPLETION OF WORK, REMOVE EXCESS ACID (FLUX)
FROM THE WORK AREA.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
CL
MIN. 1" AIR
GAP OR MATCH
EXIST. - WHICHEVER
IS GREATER
4" M
IN
8" M
IN
. F
LA
SH
IN
G
H
EI
G H
T
FIELD-FABRICATED
FLASHING
HOT STACK
NOTE: APPLY PRIMER TO ALL SURFACES WHICH WILL
RECEIVE PRESSURE SENSITIVE OUTER SEAM
FLASHING PRIOR TO APPLICATION.
3" MIN3" MIN
2 1/2"
NOTE: WHEN OUTSIDE DIAMETER OF THE PIPE
EXCEEDS 18", ADDITIONAL FIELD MEMBRANE
SECUREMENT REQUIRED. REFER TO
MANUFACTURER'S DETAILS.
PRESSURE-SENSITIVE
FLASHING - 12-INCH WIDTH.
PRESSURE-SENSITIVE
FLASHING - 9-INCH WIDTH.
PRESSURE-SENSITIVE
FLASHING - 5 OR 6-INCH
WIDTH.
PRESSURE-SENSITIVE
OUTERSEAM FLASHING;
6-INCH WIDTH. SEAL
EDGES AS SHOWN.
PRE-FABRICATED
BOOT FLASHING
EXISTING TUBULAR
PENETRATION
PIPE EXTENSION (IF NECESSARY) TO
ACHIEVE 8" MIN. FLASHING HEIGHT.
PROVIDE SEALANT AT INTERSECTION
BETWEEN EXISTING TUBULAR
PENETRATION AND EXTENSION.
24 GA. STAINLESS STEEL STORM COLLAR
SOLDER ALL LAPS AND SEAMS WATERTIGHT.
REFER TO NOTE REGARDING SOLDERING.
INSTALL BUTYL TAPE BEHIND COLLAR AS
SHOWN PRIOR TO INSTALLATION OF CLAMP.
SEAL TOP OF HOOD AS SHOWN.
SEALANT - TYP
STAINLESS STEEL CLAMPING
BAND
STAINLESS STEEL CLAMPING BAND.
PRIOR TO INSTALLATION, APPLY
MANUFACTURERS RECOMMENDED
SEALANT BEHIND EPDM FLASHING.
SEAL TOP OF FLASHING AND BAND
AFTER INSTALLATION.
EXISTING HIGH-TEMPERATURE
TUBULAR PENETRATION
PRESSURE-SENSITIVE FLASHING - 12-INCH
WIDTH.
PRESSURE-SENSITIVE FLASHING - 9-INCH
WIDTH.
PRESSURE-SENSITIVE FLASHING - 5 OR
6-INCH WIDTH.
PRESSURE-SENSITIVE OUTERSEAM
FLASHING; 6-INCH WIDTH. SEAL EDGES
AS SHOWN.
SEALANT - TYP
STAINLESS STEEL
CLAMPING BAND
SPECIFIED POLYISOCYANURATE INSULATION - TYP.
EXISTING STRUCTURAL DECK - TYP.
COVER BOARD - 1/2-INCH THICK - TYP.
EPDM ROOFING MEMBRANE - TYP.
UNDERLAYMENT - GYPSUM DECKS ONLY
24 GA. STAINLESS STEEL STORM COLLAR
SOLDER ALL LAPS AND SEAMS
WATERTIGHT. REFER TO NOTE
REGARDING SOLDERING. INSTALL BUTYL
TAPE BEHIND COLLAR AS SHOWN PRIOR
TO INSTALLATION OF CLAMP. SEAL TOP
OF HOOD AS SHOWN.
24 GA. STAINLESS STEEL FLANGED
SLEEVE. SOLDER ALL LAPS AND SEAMS
WATERTIGHT. REFER TO NOTE
REGARDING SOLDERING. SECURE TO
STRUCTURAL DECK AS SHOWN.
NOTE: EXISTING FLANGED SLEEVE
COMPONENTS DETERMINED TO BE IN
GOOD CONDITION AND FREE OF
BITUMINOUS CONTAMINATION MAY BE
CONSIDERED FOR RE-USE.
POURABLE SEALER - SLOPE TO ALLOW FOR PROPER DRAINAGE.
NON-SHRINK GROUT - FILL TO 2" BELOW RIM OF PITCH PAN.
EXISTING IRREGULAR PENETRATION - SIZE AND SHAPE VARIES.
NOTE: DO NOT USE PITCH PANS AT TUBULAR PENETRATIONS
WITHOUT PRIOR OWNER APPROVAL.
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
4" M
IN
NOTE: PRIOR TO SOLDERING OF STAINLESS STEEL, CLEAN WORK
AREA USING SOLVENTS AND WIRE BRUSH; REMOVING DIRT,
OIL, GREASE, AND OTHER CONTAMINANTS FROM THE WORK
AREA. TIN THE WORK AREA BY APPLYING ACID (FLUX).
PERFORM SOLDERING WORK. AFTER COMPLETION OF
WORK, REMOVE EXCESS ACID (FLUX) FROM THE WORK
AREA.
AT LOCATIONS WHERE POSSIBLE, PROVIDE A 24 GA. STAINLESS
STEEL JUNCTION/FLASHING BOX. FABRICATE BOX WITH A SLOPED
TOP TO SHED WATER. SOLDER ALL LAPS AND SEAMS WATERTIGHT.
SEAL PENETRATION EXIT OPENINGS WATERTIGHT.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
PRESSURE-SENSITIVE FLASHING - WIDTH AS NECESSARY TO RESULT
IN CONDITION SHOWN.
PRESSURE-SENSITIVE OUTERSEAM FLASHING; WIDTH AS NECESSARY TO
RESULT IN CONDITION SHOWN. SEAL EDGES AS SHOWN.
NOMINAL 6-INCH WOOD BLOCKING AS NECESSARY TO MATCH COVER
BOARD AND INSULATION THICKNESS. SECURE TO SUBSTRATE
18-INCHES O.C. MAX., AND WITHIN 2-INCHES OF EACH END.
4" MIN.
24 GA. STAINLESS STEEL PITCH PAN WITH 6-INCH FLANGE AND ROUNDED
CORNERS. SOLDER ALL SEAMS AND LAPS WATERTIGHT - REFER TO NOTE
REGARDING SOLDERING.
2" MIN. ALL SIDES
NOTE: APPLY PRIMER TO ALL SURFACES WHICH WILL
RECEIVE PRESSURE SENSITIVE OUTER SEAM
FLASHING PRIOR TO APPLICATION..
UNDERLAYMENT - GYPSUM DECKS ONLY
PERIMETER EDGE FLANGE CONFIGURATION
AND NAILING PATTERN DIAGRAM
SCALE: NONE
NOTE: THE PURPOSE OF THIS
DIAGRAM IS TO SHOW PERIMETER
EDGE FASCIA FLANGE FASTENING
PATTERNS AND NAILER
CONFIGURATION. THE ACTUAL
FASCIA CONFIGURATION, SIZE OF
NAILERS, AND NUMBER OF NAILERS
REQUIRED TO ACHIEVE THE
REQUIREMENTS SHOWN IN THE
DETAIL BELOW WILL VARY.
2" M
IN
. O
R T
O M
AT
C
H E
XI
ST
IN
G
E
LE
VA
TI
O N
W H
IC
H
EV
ER
IS
G
R
EA
TE
R
3/4
5/8
4"
1/2" HUG
3/
4" APPROX.
1/2"
EXISTING STRUCTURAL DECK
SPECIFIED POLYISOCYANURATE INSULATION
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
EQ
U
AL
; 7
-1 /2
" M
AX
EQ
U
AL
; 7
-1 /2
" M
AX
NOTE: EXTEND EPDM ROOFING MEMBRANE OVER AND DOWN
PERIMETER EDGE AS SHOWN. SECURE WITH ROOFING
NAILS AFFIXED WITH 1" DIAMETER METAL CAPS 12" O.C.
MAX.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
3" MIN.
6" MIN.
4" FLANGE
1/2" HUG1/2" MIN.
PRESSURE-SENSITIVE OUTER SEAM FLASHING - 9-INCH WIDTH. SEAL EDGES
AS SHOWN AFTER COMPLETION OF WORK.
PRESSURE-SENSITIVE OUTER SEAM FLASHING - 5-INCH OR 6-INCH WIDTH.
NOTE: AT A MINIMUM, PROVIDE AN ADDITIONAL 6" WIDE REINFORCEMENT
PIECE AT SHEET METAL FASCIA JOINTS. REFER TO ROOFING MEMBRANE
MANUFACTURER REQUIREMENTS FOR ADDITIONAL REQUIREMENTS AND
RECOMMENDATIONS AT SHEET METAL FASCIA JOINTS.
REINFORCED PERIMETER FASTENING STRIP WITH
FACTORY-LAMINATED SEAM TAPE. PRIME EPDM
MEMBRANE PRIOR TO APPLICATION TO REINFORCED
FASTENING STRIP.
FASTENERS AND 2-INCH PLATES, 12-INCHES O.C. MAX.
PREFINISHED 24 GA. GALV. STEEL FASCIA EXTENSION PIECE. SECURE TO SUBSTRATE 12-INCHES
O.C. MAX. WITH SPECIFIED FASTENER APPROPRIATE FOR THE SUBSTRATE ENCOUNTERED.
DECREASE FASTENER SPACING TO 6-INCHES O.C. WITHIN 10-FEET OF A BUILDING CORNER.
HOOK TO CONTINUOUS CLEAT AS SHOWN.
22 GA. GALV. STEEL CONTINUOUS CLEAT. SECURE WITH SPECIFIED FASTENER APPROPRIATE FOR
THE SUBSTRATE ENCOUNTERED 6-INCHES O.C. MAX.
NOMINAL 6-INCH WOOD BLOCKING - THICKNESS AS NECESSARY TO MATCH MAXIMUM
ROOF AREA INSULATION AND COVER BOARD THICKNESS WITH A CONSISTENT FINAL
NAILER ELEVATION. SECURE TO SUBSTRATE 18-INCHES O.C. MAX. DECREASE
FASTENER SPACING TO 9-INCHES O.C. WITHIN 10-FEET OF A BUILDING CORNER.
22 GA. GALV. STEEL CONTINUOUS CLEAT. SECURE FLANGE AND VERTICAL FACE
WITH SPECIFIED FASTENER APPROPRIATE FOR THE SUBSTRATE ENCOUNTERED
6-INCHES O.C. MAX.
PREFINISHED 24 GA. GALV. STEEL FASCIA PIECE. FABRICATE AS SHOWN. SECURE FLANGE
WITH NAILS 3-INCHES O.C. MAX. IN TWO STAGGERED ROWS (REFER TO DIAGRAM ABOVE).
HOOK TO CONTINUOUS CLEAT AS SHOWN.
NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN
24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER
THE REQUIREMENTS AND RECOMMENDATIONS OF THE
EPDM ROOFING MEMBRANE MANUFACTURER.
SECURE TOP EDGE OF FLASHING USING AN ALUMINUM
TERMINATION BAR SECURED 12-INCHES O.C., MAX., AND
WITHIN 2-INCHES OF EACH END. PRIOR TO TERMINATION
BAR INSTALLATION, INSTALL MANUFACTURERS
RECOMMENDED SEALANT BEHIND FLASHING WHERE
TERMINATION BAR WILL BE PLACED. SEAL TOP EDGE OF
FLASHING AND TERMINATION BAR AFTER INSTALLATION.
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS
FOLLOWING THE RECOMMENDATIONS AND REQUIREMENTS
OF THE ROOFING MEMBRANE MANUFACTURER. PROVIDE
"T-JOINT COVERS" AT THE BASE OF THE CURB AT FLASHING
PIECE INTERSECTIONS.
2" M
IN
. O
R T
O M
AT
C
H
EX
IS
TI
N G
E
LE
VA
TI
O N
W H
IC
H
EV
ER
IS
G
R
EA
TE
R
4" M
IN
. F
AC
E
COPING CAP JOINT PROFILE
SINGLE-LOCK STANDING SEAM; FOR USE WHERE
ADJACENT COPING CAPS ARE TO BE JOINED. AT STANDING
SEAM ENDS, CUT AT 45-DEGREE ANGLE, FOLD EAR OVER
END, AND CRIMP.
1"
SEALANT - SEAL BOTH ENDS OF STANDING SEAM
PARAPET WALL STEEL COPING CAP
PARAPET WALL STEEL COPING CAP
8" M
IN
IM
U M
DIMENSION "X"
"X" "2X" "X"
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING
STRIP WITH FACTORY-LAMINATED SEAM
TAPE. PRIME EPDM MEMBRANE PRIOR TO
APPLICATION TO REINFORCED FASTENING
STRIP.
EPDM FLASHING MEMBRANE, FULLY
ADHERED TO CURB
FASTENERS AND 2-INCH PLATES,
12-INCHES O.C. MAX.
APPROX.
1/2"
COVER BOARD - 1/2-INCH THICK
EPDM MEMBRANE - FULLY-ADHERED. INSTALL
OVER OVER 3/4-INCH PLYWOOD.
22 GA. GALV. STEEL BACKER PIECE. FABRICATE WITH 2-INCH
FLANGES AT EACH END, AND AS NEEDED TO CREATE 1/2-INCH PER
FOOT SLOPE OFF OF HORIZONTAL CAP SURFACE. SECURE EACH
FLANGE WITH RING SHANK COATED NAILS 12-INCHES O.C. MAX.
WOOD BLOCKING AS NECESSARY TO ACHIEVE 8-INCH MIN.
FLASHING HEIGHT; WIDTH AS NECESSARY TO MATCH EXISTING
CURB WIDTH. SECURE TO SUBSTRATE 18-INCHES O.C. MAX.
3/4-INCH PLYWOOD - SECURE TO ONE SIDE OF EXPANSION JOINT
ONLY. SECURE TO SUBSTRATE 18-INCHES O.C. MAX.
BATT INSULATION IN POLYETHYLENE SHEET. LAP POLYETHYLENE
SHEETS 24-INCHES MINIMUM. SECURE POLYETHYLENE SHEETS TO
TOP OF EXPANSION JOINT CURBS WITH CAP NAILS.
TWO-PIECE PREFINISHED 24 GA. GALV. STEEL EXPANSION
JOINT COVER. FABRICATE AS SHOWN; SECURE EXPANSION
JOINT VERTICAL FACES WITH GASKETED FASTENERS
APPROPRIATE FOR THE SUBSTRATE ENCOUNTERED
18-INCHES O.C. MAX., AND WITHIN 2-INCHES OF EACH END.
JOIN ADJACENT CAP SECTIONS USING 1-INCH HIGH,
SINGLE-LOCK STANDING SEAMS. BUTTON PUNCH BOTH ENDS.
FIELD VERIFY REQUIRED EXPANSION JOINT WIDTH
"X"
TWO-PIECE PREFINISHED 24 GA. GALV. STEEL EXPANSION JOINT
COVER. FABRICATE AS SHOWN; SECURE EXPANSION JOINT
VERTICAL FACES WITH GASKETED FASTENERS APPROPRIATE
FOR THE SUBSTRATE ENCOUNTERED 18-INCHES O.C. MAX., AND
WITHIN 2-INCHES OF EACH END. JOIN ADJACENT CAP SECTIONS
USING 1-INCH HIGH STANDING SEAMS.
WOOD BLOCKING AS NECESSARY TO ACHIEVE 8-INCH MIN.
FLASHING HEIGHT; WIDTH AS NECESSARY TO MATCH EXISTING
CURB WIDTH. SECURE TO SUBSTRATE 18-INCHES O.C. MAX.
BATT INSULATION IN POLYETHYLENE SHEET. LAP POLYETHYLENE
SHEETS 24-INCHES MINIMUM. SECURE POLYETHYLENE SHEETS TO
TOP OF EXPANSION JOINT CURBS WITH CAP NAILS.
NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN
24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER
THE REQUIREMENTS AND RECOMMENDATIONS OF THE
EPDM ROOFING MEMBRANE MANUFACTURER.
SECURE TOP EDGE OF FLASHING USING AN ALUMINUM
TERMINATION BAR SECURED 12-INCHES O.C., MAX., AND WITHIN
2-INCHES OF EACH END. PRIOR TO TERMINATION BAR
INSTALLATION, INSTALL MANUFACTURERS RECOMMENDED
SEALANT BEHIND FLASHING WHERE TERMINATION BAR WILL BE
PLACED. SEAL TOP EDGE OF FLASHING AND TERMINATION BAR
AFTER INSTALLATION.
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS
FOLLOWING THE RECOMMENDATIONS AND REQUIREMENTS
OF THE ROOFING MEMBRANE MANUFACTURER. PROVIDE
"T-JOINT COVERS" AT THE BASE OF THE CURB AT FLASHING
PIECE INTERSECTIONS.
4" M
IN
. F
AC
E
8" M
IN
. F
LA
SH
IN
G
H
EI
G H
T
PREFINISHED 24 GA. GALV. STEEL SURFACE MOUNTED
COUNTERFLASHING, SECURED WITH GASKETED FASTENERS
APPROPRIATE FOR THE SUBSTRATE 12-INCHES O.C. MAX.
4" M
IN
. ENLARGED REGLET
DETAIL
SCALE: NONE
CUT REGLET INTO WALL
AS SHOWN
SEALANT
PREFINISHED 24 GA. GALV.
STEEL COUNTERFLASHING,
SPRING-LOCKED INTO REGLET
AND SECURED WITH GASKETED
FASTENERS APPROPRIATE FOR
THE SUBSTRATE 12-INCHES O.C.
MAX.
FU
LL W
ID
TH
O F M
ASO
N
R Y
G R
O U
T JO
IN
T
APPR
O
X.
1-1/4"
APPROX. 1"
DEEP
DIMENSION "X"
"X"
"X'
"2X"
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING
STRIP WITH FACTORY-LAMINATED SEAM
TAPE. PRIME EPDM MEMBRANE PRIOR TO
APPLICATION TO REINFORCED FASTENING
STRIP.
EPDM FLASHING MEMBRANE, FULLY
ADHERED TO CURB
FASTENERS AND 2-INCH PLATES,
12-INCHES O.C. MAX.
APPROX.
1/2"
CONTINUOUS EPDM FLASHING MEMBRANE WITH SEALED LAPS
COVER BOARD - 1/2-INCH THICK
BUTYL SEALANT
SEALANT
CLIENT
PROFESSIONAL
PROJECT
DESCRIPTIONDATE
ISSUE
Drawn By: PD
Checked By: SH
SHEET TITLE
File Name:
STAMP
SHEET 04 OF 06
ROOF PLAN
DETAILS 01-08
Testing Engineers & Consultants
1343 Rochester Road Troy, MI 48083
DETAIL 01 -
SCALE: NONE
ROOF CURB FLASHING DETAIL 02 -
SCALE: NONE
ROOF HATCH CURB FLASHING DETAIL 03 -
SCALE: NONE
SUPPORT CURB FLASHING
DETAIL 04 -
SCALE: NONE
DETAIL 05 -
SCALE: NONE
DETAIL 06 -
SCALE: NONE
PITCH PAN FLASHING
DETAIL 07 -
SCALE: NONE
PERIMETER EDGE FLASHING DETAIL 08 -
SCALE: NONE
ROOF-TO-ROOF EXPANSION JOINT FLASHING
Detroit Public Schools
3011 W. Grand Blvd Detroit, MI 48202
TUBULAR PENETRATION FLASHING ROOF DRAIN FLASHING
DETAIL 09 -
SCALE: NONE
ROOF-TO-WALL EXPANSION JOINT FLASHING
75% Design Review Set03-16-2026
Burton International Academy
4" M
IN
8" M
IN
2" M
IN
4" M
IN
M
AX
. H
EI
G H
T
PO
SS
IB
LE
1" M
IN
PREFINISHED 24 GA. GALV. STEEL SLIP
COUNTERFLASHING. SECURE TO EXISTING
COUNTERFLASHING AS SHOWN USING GASKETED
FASTENERS 12-INCHES O.C. MAX., AND WITHIN
2-INCHES OF EACH END.
EXISTING COUNTERFLASHING
EXISTING METAL WALL SIDING - DO NOT DISTURB.
ALTERNATE COUNTERFLASHING NO. 1
FOR USE BELOW EXISTING WALL WHERE 8-INCH MINIMUM FLASHING
HEIGHT CAN BE ACHIEVED.
ALTERNATE COUNTERFLASHING NO. 2
FOR USE BELOW EXISTING WALL WHERE 8-INCH MINIMUM FLASHING
HEIGHT CANNOT BE ACHIEVED.
PREFINISHED 24 GA. GALV. STEEL SLIP
COUNTERFLASHING. SECURE TO EXISTING
COUNTERFLASHING AS SHOWN USING GASKETED
FASTENERS 12-INCHES O.C. MAX., AND WITHIN
2-INCHES OF EACH END.
EXISTING COUNTERFLASHING - CUT AS SHOWN.
EXISTING METAL WALL SIDING - DO NOT DISTURB.
NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN
24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER
THE REQUIREMENTS AND RECOMMENDATIONS OF THE
EPDM ROOFING MEMBRANE MANUFACTURER.
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS FOLLOWING
THE RECOMMENDATIONS AND REQUIREMENTS OF THE ROOFING
MEMBRANE MANUFACTURER. PROVIDE "T-JOINT COVERS" AT THE
BASE OF THE CURB AT FLASHING PIECE INTERSECTIONS.
SECURE TOP EDGE OF FLASHING USING AN ALUMINUM
TERMINATION BAR SECURED 12-INCHES O.C., MAX., AND
WITHIN 2-INCHES OF EACH END. PRIOR TO TERMINATION
BAR INSTALLATION, INSTALL MANUFACTURERS
RECOMMENDED SEALANT BEHIND FLASHING WHERE
TERMINATION BAR WILL BE PLACED. SEAL TOP EDGE OF
FLASHING AND TERMINATION BAR AFTER INSTALLATION.
NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND
COUNTERFLASHING, INSPECT EXISTING WALLS
FOR THE PRESENCE OF MASONRY WEEPS AND
OTHER WALL DRAINAGE MECHANISMS. DO NOT
COVER WEEPS, OR IMPEDE THE ABILITY OF
MOISTURE TO EXIT WALL SYSTEMS.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING
STRIP WITH FACTORY-LAMINATED SEAM
TAPE. PRIME EPDM MEMBRANE PRIOR TO
APPLICATION TO REINFORCED FASTENING
STRIP.
EPDM FLASHING MEMBRANE, FULLY
ADHERED TO CURB
FASTENERS AND 2-INCH PLATES,
12-INCHES O.C. MAX.
COVER BOARD - 1/2-INCH THICK
APPROX.
1/2"
3/4-INCH PLYWOOD MECHANICALLY ATTACHED TO EXISTING
WALL WITH PROPER SUBSTRATE FASTENERS - TWO ROWS
24-INCHES O.C., STAGGERED
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING
STRIP WITH FACTORY-LAMINATED SEAM
TAPE. PRIME EPDM MEMBRANE PRIOR TO
APPLICATION TO REINFORCED FASTENING
STRIP.
EPDM FLASHING MEMBRANE, FULLY
ADHERED TO CURB
FASTENERS AND 2-INCH PLATES,
12-INCHES O.C. MAX.
COVER BOARD - 1/2-INCH THICK
APPROX.
1/2"
3/4-INCH PLYWOOD MECHANICALLY ATTACHED TO EXISTING
WALL WITH PROPER SUBSTRATE FASTENERS - TWO ROWS
24-INCHES O.C., STAGGERED
SECURE TOP EDGE OF FLASHING USING AN ALUMINUM
TERMINATION BAR SECURED 12-INCHES O.C., MAX., AND
WITHIN 2-INCHES OF EACH END. PRIOR TO TERMINATION
BAR INSTALLATION, INSTALL MANUFACTURERS
RECOMMENDED SEALANT BEHIND FLASHING WHERE
TERMINATION BAR WILL BE PLACED. SEAL TOP EDGE OF
FLASHING AND TERMINATION BAR AFTER INSTALLATION.
NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN
24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER
THE REQUIREMENTS AND RECOMMENDATIONS OF THE
EPDM ROOFING MEMBRANE MANUFACTURER.
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS FOLLOWING
THE RECOMMENDATIONS AND REQUIREMENTS OF THE ROOFING
MEMBRANE MANUFACTURER. PROVIDE "T-JOINT COVERS" AT THE
BASE OF THE WALL AT FLASHING PIECE INTERSECTIONS.
NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND
COUNTERFLASHING, INSPECT EXISTING WALLS FOR THE
PRESENCE OF MASONRY WEEPS AND OTHER WALL DRAINAGE
MECHANISMS. DO NOT COVER WEEPS, OR IMPEDE THE ABILITY
OF MOISTURE TO EXIT WALL SYSTEMS.
PREFINISHED 24 GA. GALV. STEEL REGLETED
COUNTERFLASHING. SECURE TO SUBSTRATE WITH
GASKETED FASTENERS 12-INCHES O.C., MIN. 2
FASTENERS.
SEALANT
CUT SIDING TO WALL
2" M
IN
1" M
IN
PREFINISHED 24 GA. GALV. STEEL PARAPET CAP.
TURN UP WALL 2-INCHES, MIN., INSTALL BUTYL TAPE
BEHIND TURN-UP, AND SECURE.
FULLY-ADHERED EPDM FLASHING MEMBRANE
COPING CAP TERMINATION
AT END WALLS
FOR USE WHERE PARAPET WALLS AND
RELATED COPING CAPS TERMINATE
INTO VERTICAL WALLS.
PREFINISHED 24 GA. GALV. STEEL REGLETED
COUNTERFLASHING. SECURE TO SUBSTRATE WITH
GASKETED FASTENERS 12-INCHES O.C., MIN. 2
FASTENERS.
SEALANT
CUT REGLET INTO WALL
2" M
IN
1" M
IN
PREFINISHED 24 GA. GALV. STEEL PARAPET CAP.
TURN UP WALL 2-INCHES, MIN., INSTALL BUTYL TAPE
BEHIND TURN-UP, AND SECURE.
FULLY-ADHERED EPDM FLASHING MEMBRANE
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
NOTE: MEMBRANE MUST BE EXTENDED TO CORNERS TO PROVIDE
COMPLETE COVERAGE OF THE WALL SURFACE.
COPING CAP JOINT PROFILE
SINGLE-LOCK STANDING SEAM; FOR USE WHERE
ADJACENT COPING CAPS ARE TO BE JOINED, BUTTON PUNCH.
1"
SEALANT - SEAL BOTH ENDS OF
STANDING SEAM
PARAPET WALL STEEL COPING CAP
BUTTON PUNCH
3" M
IN
2" M
IN
. O
R T
O M
AT
C
H
EX
IS
TI
N G
E
LE
VA
TI
O N
W H
IC
H
EV
ER
IS
G
R
EA
TE
R
3/4
5/8
7- 1/
IN
C H
M
AX
PREFINISHED 24 GA. GALV. STEEL COPING CAP.
HOOK OUTSIDE FACE TO CONTINUOUS CLEAT,
AND SECURE INNER FACE WITH GASKETED
FASTENERS APPROPRIATE FOR THE
SUBSTRATE ENCOUNTERED 18-INCHES O.C.
MAX., AND WITHIN 2-INCHES OF EACH END.
JOIN ADJACENT CAP SECTIONS USING 1-INCH
HIGH, SINGLE-LOCK STANDING SEAMS.
BUTTON PUNCH BOTH ENDS.
EXISTING STRUCTURAL DECK
SPECIFIED POLYISO. INSULATION
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING
STRIP WITH FACTORY-LAMINATED SEAM
TAPE. PRIME EPDM MEMBRANE PRIOR TO
APPLICATION TO REINFORCED FASTENING
STRIP.
EPDM FLASHING MEMBRANE, FULLY
ADHERED TO CURB
FASTENERS AND 2-INCH PLATES,
12-INCHES O.C. MAX.
COVER BOARD - 1/2-INCH THICK
3/4-INCH PLYWOOD MECHANICALLY ATTACHED TO
EXISTING WALL WITH PROPER SUBSTRATE FASTENERS;
TWO ROWS 24-INCHES O.C., STAGGERED
UNDERLAYMENT - GYPSUM DECKS ONLY
22 GA. GALV. STEEL CONTINUOUS CLEAT. FABRICATE AS SHOWN TO
CREATE 1/2-INCH PER FOOT SLOPE TOWARD INNER FACE. SECURE
HORIZONTAL FLANGE AND VERTICAL FACE WITH RING SHANK COATED
NAILS 6-INCHES O.C. MAX.
EXTEND FULLY-ADHERED EPDM FLASHING MEMBRANE UP AND
OVER PARAPET WALL, AND DOWN OUTSIDE FASCIA. APPLY
SEALANT TO BACK SIDE OF FLASHING MEMBRANE, AND SECURE
12" O.C. MAX.
H
EI
G H
T
VA
R
IE
S;
-IN
C
H M
IN
IM
U M
NOMINAL 2-INCH THICK WOOD BLOCKING - WIDTH AS NECESSARY
TO MATCH EXISTING PARAPET WALL WIDTH. THICKNESS AS
NECESSARY TO ACHIEVE 4-INCH MINIMUM FLASHING HEIGHT.
SECURE TO SUBSTRATE 18-INCHES O.C. MAX. DECREASE
FASTENER SPACING TO 9-INCHES O.C. WITHIN 10-FEET OF A
BUILDING CORNER.
WALL FLASHING AT WINDOW
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
SECURE TOP EDGE OF FLASHING USING AN ALUMINUM TERMINATION BAR
SECURED 12-INCHES O.C., MAX., AND WITHIN 2-INCHES OF EACH END. PRIOR TO
TERMINATION BAR INSTALLATION, INSTALL MANUFACTURERS RECOMMENDED
SEALANT BEHIND FLASHING WHERE TERMINATION BAR WILL BE PLACED. SEAL
TOP EDGE OF FLASHING AND TERMINATION BAR AFTER INSTALLATION.
LIQUID APPLIED FLASHING
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS FOLLOWING
THE RECOMMENDATIONS AND REQUIREMENTS OF THE ROOFING
MEMBRANE MANUFACTURER. PROVIDE "T-JOINT COVERS" AT THE
BASE OF THE CURB AT FLASHING PIECE INTERSECTIONS.
NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND
COUNTERFLASHING, INSPECT EXISTING WALLS FOR THE
PRESENCE OF MASONRY WEEPS AND OTHER WALL DRAINAGE
MECHANISMS. DO NOT COVER WEEPS, OR IMPEDE THE ABILITY
OF MOISTURE TO EXIT WALL SYSTEMS.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
PRESSURE SENSITIVE FLASHING
EXISTING WINDOW FRAME AND TERNE-COATED METAL
EXISTING WINDOW GLAZING
REINFORCED PERIMETER FASTENING
STRIP WITH FACTORY-LAMINATED SEAM
TAPE. PRIME EPDM MEMBRANE PRIOR TO
APPLICATION TO REINFORCED FASTENING
STRIP.
FASTENERS AND 2-INCH PLATES,
12-INCHES O.C. MAX.
EPDM FLASHING MEMBRANE, FULLY
ADHERED TO CURB
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS
FOLLOWING THE RECOMMENDATIONS AND REQUIREMENTS
OF THE ROOFING MEMBRANE MANUFACTURER. PROVIDE
"T-JOINT COVERS" AT THE BASE OF THE CURB AT FLASHING
PIECE INTERSECTIONS.
1-1/2" MIN.
HOT AIR WELD
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
UNDERLAYMENT - GYPSUM DECKS ONLY
PLAN VIEW OF THROUGH ROOF PIPE CURB
SCALE: NONE
4" M
IN
8" M
IN
NOMINAL WOOD BLOCKING - THICKNESS AS NECESSARY TO
MATCH MAXIMUM ROOF AREA INSULATION AND COVER
BOARD THICKNESS WITH A CONSISTENT FINAL NAILER
ELEVATION.
COMPRESSIBLE/BATT INSULATION AS SPECIFIED
REMOVABLE SHEET METAL COUNTERFLASHING
FLEXIBLE INSULATION RETAINER ATTACHED TO TOP OF CURB
SHEET METAL FLASHING RECIEVER
SLOPE PIPES DOWN AND AWAY FROM HOOD
SHEET METAL OR FLEX-TUBE COLLAR
SEALANT AS SPECIFIED
SHEET METAL ENCLOSURE- CROSS BREAK OR SLOPE FOR
DRAINAGE
REINFORCED PERIMETER FASTENING
STRIP WITH FACTORY-LAMINATED SEAM
TAPE. PRIME EPDM MEMBRANE PRIOR TO
APPLICATION TO REINFORCED FASTENING
STRIP.
FASTENERS AND 2-INCH PLATES,
12-INCHES O.C. MAX.
CLIENT
PROFESSIONAL
PROJECT
DESCRIPTIONDATE
ISSUE
Drawn By: PD
Checked By: SH
SHEET TITLE
File Name:
STAMP
SHEET 05 OF 06
ROOF PLAN
DETAILS 10-13
Testing Engineers & Consultants
1343 Rochester Road Troy, MI 48083
DETAIL 10 -
SCALE: NONE
ROOF-TO-WALL FLASHING DETAIL 11 -
SCALE: NONE
PARAPET WALL FLASHING DETAIL 12 -
SCALE: NONE
ROOF-TO-WALL HASHING AT WINDOW
DETAIL 13 -
SCALE: NONE
MULTIPLE PENETRATION CHASE
Detroit Public Schools
3011 W. Grand Blvd Detroit, MI 48202
75% Design Review Set03-16-2026
Burton International Academy
R
R
CLIENT
PROFESSIONAL
PROJECT
DESCRIPTIONDATE
ISSUE
Drawn By: PD
Checked By: SH
SHEET TITLE
File Name:
STAMP
SHEET 06 OF 06
WALK PAD
LAYOUT PLAN
Testing Engineers & Consultants
1343 Rochester Road Troy, MI 48083
Detroit Public Schools
3011 W. Grand Blvd Detroit, MI 48202
75% Design Review Set03-16-2026
Burton International Academy
2001 Martin Luther King Jr Blvd Detroit, MI 48208
PROJECT SPECIFIC KEY NOTES:
CONTRACTOR SHALL PROVIDE WALK PADS WHERE INDICATED ON ROOF PLAN -
REFER TO SECTION 075323 FOR PRODUCT REQUIREMENTS.
CONTRACTOR SHALL PROVIDE NEW STAIR/PLATFORM CROSSOVERS WHERE
INDICATED ON ROOF PLAN - REFER TO SECTION 075323 FOR PRODUCT
REQUIREMENTS
A
B
A TYP.
A TYP.
A TYP.
A TYP.
B
B
| 1-3 |
| Sheets and Views |
| Sheets 1-4-Sh 1 |
| Sheets 1-4-SH 2 |
| Sheets 1-4-sh 3 |
| Sheets 1-4-sh 6 |
| SH 4 |
| Sheets and Views |
| details-sh 4 |
| details-SH 5 |
File details come from the government source that posted it. Updated .