This is a roof assessment report for Detroit Public Schools' Burton International Academy located at 5536 St. Antoine Street in Detroit, Michigan, dated March 9, 2026. The visual inspection evaluated the condition and remaining service life of the existing roof system across nine distinct roof areas (A through I) totaling approximately 69,296 square feet. The assessment found that all roof areas, which were installed prior to 2000, feature deteriorated built-up roofing (BUR) systems exhibiting membrane deterioration, flashing failures, metal counterflashing corrosion, failed sealants, blistering, and compromised pitch pans. The inspection identified significant wear patterns including large repairs along gutter edges and roof-to-wall flashing issues, indicating the roofs have exceeded their serviceable life.

The assessment recommends complete roof system replacement for all areas, with Roof Areas A, B, C, D, E, G, and I requiring removal down to the existing structural steel deck and installation of a new system comprising 2-1/2 inch polyiso base layer, 1/8-inch tapered polyiso, 1/2-inch high-density polyiso, and a fully adhered 60-mil EPDM membrane. Roof Area F, which sits on a gypsum deck, requires a mechanically attached base sheet with the same membrane system. Area H specifications are not detailed in the recommendations. The total estimated construction cost for an R-30 insulation system with 60-mil EPDM membrane is $2,787,099.00. This assessment serves as the technical basis for the related Facility Master Plan Series 6 Roof Replacement contract opportunity for Detroit Public Schools.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Detroit Public Schools – Burton International Academy

5536 St. Antoine Street Detroit, MI 48202

March 9th, 2026

Detroit Public Schools – Burton International Academy

Table of Contents

Executive Summary Page 3

Roof Plan Page 4

Roof Area Descriptions Page 5

Roof Area Photos Page 12

EXECUTIVE SUMMARY

On March 9, 2026 a visual inspection of the existing roof system was performed. The purpose of this inspection was to determine the estimated surface life left of the existing roof system. Roof Areas A, B, C, D, E, G & I existing systems consisted of an existing BUR aggregate surface, 1/2-inch perlite, 1/2-inch perlite, tapered polyiso and 2-1/2 inch polyiso over steel deck. Roof Area F existing system consisting of a BUR aggregate surface, 1/2-inch perlite, 2- inch polyiso and 2-inch polyiso over a gypsum deck.

Observations & Recommendations:

Roof Areas A, B, C, D, E, G & I: Remove existing roof system down to the existing structural steel deck. Install base layer of 2-1/2 inch polyiso, 1/8-inch tapered polyiso, 1/2-inch high density polyiso and a fully adhered 60-mil EPDM membrane.

Roof Area F: Remove existing roof system down to the existing structural gypsum deck. Install mechanically attached, base sheet layer of 2-1/2 inch polyiso, 1/8-inch per foot tapered polyiso, 1/2-inch high density polyiso and fully-adhered 60-mil EPDM membrane.

Estimated Construction Costs:

R-30 Insulation System with a fully-adhered 60-mil EPDM: $2,787,099.00

ROOF PLAN:

Note: Remaining life of existing roof systems is based on the estimated age of the roofs, visual inspection and assuming no maintenance being performed.

ROOF AREA DESCRIPTIONS:

Roof Area ID: A

Size: 22,251 sf.

Year Installed: Pre 2000

Height: 16 ft

Structural Slope: None

Drainage: Roof Drains

Roof Area ID: B

Size: 4,320 sf.

Year Installed: Pre 2000

Height: 24 ft

Roof Area ID: C

Size: 8,703 sf.

Year Installed: Pre 2000

Height: 13 ft.

Roof Area ID: D

Size: 3,600 sf.

Year Installed: Pre 2000

Height: 13 ft.

Roof Area ID: E

Size: 4,860 sf.

Year Installed: Pre 2000

Height: 13 ft.

Roof Area ID: F

Size: 15,664 sf.

Year Installed: Pre 2000

Height: 28 ft.

Structural Slope: 1/8” per foot.

Roof Area ID: G

Size: 896 sf.

Year Installed: Pre 2000

Height: 16 ft

Roof Area ID: H

Size: 8,962 sf.

Year Installed: Pre 2000

Height: 24 ft.

Roof Area ID: I

Size: 40 sf.

Year Installed: Pre 1995

Height: 24 ft.

ROOF AREA PHOTOS:

Membrane deterioration Membrane flashing deterioration

Overview Membrane flashing deterioration

Large repair along gutter edge

Membrane blister

Metal counterflashing deterioration/failed sealant

Repair made to roof-to-wall flashing

Metal counterflashing deterioration/failed sealant/ Repair made to roof-to-wall flashing

Failed pitch pan/ no longer watertight