PROJECT MANUAL – VOLUME II
100% CONSTRUCTION DOCUMENTS
JEMEZ RANGER DISTRICT OFFICE COMPLEX
FOR
USDA FOREST SERVICE, SOUTHWESTERN REGION
SANTA FE NATIONAL FOREST
JEMEZ SPRINGS RANGER DISTRICT
JULY 1, 2019
PROJECT MANUAL – VOLUME II
100% CONSTRUCTION DOCUMENTS
JEMEZ RANGER DISTRICT OFFICE COMPLEX
FOR
USDA FOREST SERVICE, SOUTHWESTERN REGION
SANTA FE NATIONAL FOREST
JEMEZ SPRINGS RANGER DISTRICT
JVA, Inc.
1319 Spruce Street Boulder, CO 80302 phone: 303-444-1951
JVA Project No. 2339.15.1c
JULY 1, 2019
SECTION 09 65 00
RESILIENT FLOORING
JEMEZ DISTRICT OFFICE 09 65 00-1
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Resilient flooring.
B. Resilient wall base.
C. Flooring system accessories.
1.2 REFERENCE STANDARDS
A. ASTM F1861 - Standard Specification for Resilient Wall Base.
B. ASTM F2034 - Standard Specification for Sheet Linoleum Floor Covering.
1.3 SUBMITTALS
A. See Section 01 30 00 - Administrative Requirements, for submittal procedures.
B. Product Data: Provide data on specified products, describing physical and performance characteristics; including sizes, patterns and colors available; and installation instructions.
C. Verification Samples: Submit two samples, 6x6 inch in size illustrating color and pattern for each resilient flooring product specified.
D. Certification: Prior to installation of flooring, submit written certification by flooring manufacturer and adhesive manufacturer that condition of sub-floor is acceptable.
E. Sample Warranty
F. EPD (Environmental Product Declaration) 3.5.1.2 Path B: Prescriptive Path Option 1
Environmental Product Declaration
a. Submit product data or other published information verifying that this product has an
EPD. Submit in accordance with Section 018113, Green Globes Submittals Forms and
– 3.5 MATERIALS AND RESOURCES credit 3.5.1.2
Environmental Product Declarations.
The Following third party certifications are compliant with credits in section 3.5 of the
Green Globes reference guide:
• NSF/ANSI 140: Sustainability Assessment for Carpet
• NSF/ANSI 332: Sustainability Assessment for Resilient Flooring
• NSF/ANSI 342: Sustainability Assessment for Wallcovering Products
JEMEZ DISTRICT OFFICE 09 65 00-2
• NSF/ANSI 336: Sustainability Assessment for Commercial Furnishings Fabric
• Sustainable Minds (SM) Transparency ReportTM Program
• ANSI/NSC 373: Sustainable Production of Natural Dimension Stone
• ANSI/BIFMA e3-2014e: Furniture Sustainability Standard
• ANSI A138.1 Green Squared-American National Standard Specifications for
Sustainable Ceramic Tiles, Glass Tiles, and Tile Installation
Materials.
• UL 100: Standard for Sustainability for Gypsum Boards and Panels
• UL 102: Standard for sustainability for Swinging Door Leafs
• UL (STP) 106: Sustainability for Luminaires
• UL (STP) 115: Thermal Insulation
b. Include information Contractor Materials Calculator.
G. Source Control and Measurement of Indoor Pollutants Volatile Organic Compounds
Flooring (3.7.2.1.2 and 3.7.2.1.4)
a. Submit product data or other published information verifying compliance with VOC emissions results are determined by California Department of Public Health (CDPH)
“Standard Method for the Testing and Evaluation of Volatile Organic Chemical
Emissions from Indoor Sources Using
Environmental Chambers,” V 1.1, 2010, Standard Private Office Scenario or VOC emission results are determined by UL 2821 “GREENGUARD Certification Program
Method for Measuring and Evaluating Chemical Emissions from Building Materials, Finishes and Furnishings,” March 2013, Table 2 Office Model and Section 34.1
Allowable Limits for GREENGUARD Certification Gold.
b. Other accepted third party certifications for flooring compliance are:
• Floorscore
• Green Guard Gold
• Indoor Advantage Gold
c. Include information on Contractor Source Control and Measurement of Indoor
Pollutants Materials Calculator.
JEMEZ DISTRICT OFFICE 09 65 00-3
1.4 CLOSEOUT
A. Maintenance Data: Include maintenance procedures, recommended maintenance materials, and suggested schedule for cleaning, stripping, and re-waxing.
B. Maintenance Materials: Furnish the following for Government's use in maintenance of project.
1. Extra Flooring Material: 50 square feet of each type and color.
2. Extra Wall Base: 24 linear feet of each type and color.
3. Clearly identify each package.
4. Warranty: Furnish executed warranty in Government's name.
1.5 QUALITY ASSURANCE
A. Manufacturer Qualifications: Company specializing in manufacturing specified flooring with minimum three years documented experience.
B. Installer Qualifications: Company specializing in installing specified flooring with minimum three years documented experience.
1.6 DELIVERY, STORAGE, AND HANDLING
A. Deliver and store materials in manufacturer's original unopened containers, with brand names and production lot numbers clearly marked.
1.7 FIELD CONDITIONS
A. Store materials for not less than 48 hours prior to installation in area of installation at a minimum temperature of 65 degrees F to achieve temperature stability. Thereafter, maintain conditions above 55 degrees F.
B. Install resilient flooring and accessories after other finishing operations, including painting have been completed.
C. Do not install resilient flooring over concrete slabs until slabs have been fully cured, and are sufficiently dry to achieve proper bond with adhesive as determined by resilient flooring manufacturer's recommended bond and moisture test.
1.8 WARRANTY
A. See Section 01 77 00 - Closeout Procedures, for additional warranty requirements.
B. Resilient Flooring: Provide manufacturer's warranty, as follows:
1. Materials: Minimum 2 years from date of purchase.
2. Installation: Minimum 2 years from date of installation; warrant entire installation against loss of adhesion to substrates.
JEMEZ DISTRICT OFFICE 09 65 00-4
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Acceptable Manufacturers:
1. Manufacturers and products specified on Drawings or equal.
2.2 SHEET FLOORING
A. Linoleum Sheet Flooring: Homogeneous wear layer bonded to backing, with color and pattern through wear layer thickness.
1. Manufacturers:
a. Forbo Flooring, Inc: www.forboflooringna.com/#sle.
2. Minimum Requirements: Comply with ASTM F2034, Type corresponding to type specified.
3. Backing: Jute fabric.
4. Wear Layer Thickness: 0.080 inch, minimum, excluding backing.
5. Color: As shown on Drawings.
6. Seams: Heat welded.
B. Linoleum Welding Rod: Solid color linoleum produced by flooring manufacturer for heat welding seams, in color in color matching predominant flooring color.
2.3 STAIR COVERING
A. Stair Treads and Risers: Rubber; full width and depth of stair tread in one piece;
tapered thickness; nosing not less than 1-5/8 inch deep.
1. Manufacturers:
a. Roppe Corp; #80: www.roppe.com or equal
2. Nominal Thickness: 0.1875 inch.
3. Nosing: Tapered.
4. Striping: 2 inch wide contrasting color abrasive strips.
5. Texture: Raised.
6. Style: Contrasting color abrasive grit strips full width.
7. Color: Solid.
2.4 RESILIENT BASE
A. Resilient Base: ASTM F1861, Type TS rubber, vulcanized thermoset; top set Style B, Cove.
1. Height: 4 inch.
2. Thickness: 0.080 inch thick.
3. Finish: Satin.
4. Length: Roll.
5. Color: As shown on drawings.
6. Accessories: Premolded external corners and end stops.
JEMEZ DISTRICT OFFICE 09 65 00-5
2.5 ACCESSORIES
A. Subfloor Filler: White premix latex; type recommended by adhesive material manufacturer.
B. Adhesive: Water based type, zero (0) VOC content, spray application.
1. Acceptable Manufacturer: Interlock Industries; Spray-Lock Adhesive:
www.spraylock.com.
a. Substitutions: See Section 01 60 00 - Product Requirements.
C. Moldings and Edge Strips: Homogeneous vinyl or rubber type; tapered or bullnose edge; one inch wide; color selected by Architect.
D. Sealer and Wax: Types recommended by flooring manufacturer as applicable.
2.6 EPD (Environmental Product Declaration) 3.5.1.2 Path B:
A. Prescriptive Path Option 1 Environmental Product Declaration
Preference should be given to materials/products that meet the requirements for the
Green Globes credit 3.5.2.2 Path B: Prescriptive Path for Interior Fit-outs.
B. Source Control and Measurement of Indoor Pollutants Volatile Organic Compounds
Flooring (3.7.2.1.2 and 3.7.2.1.4)
Flooring: (select applicable)
- Carpet in this section must meet the requirements of the California Department of
Public Health (CDPH) “Standard Method for the Testing and Evaluation of Volatile
Organic Chemical Emissions from Indoor Sources Using Environmental Chambers,” V
1.1, 2010, Standard Private Office Scenario or VOC emission results are determined by
UL 2821 “GREENGUARD Certification Program Method for Measuring and
Evaluating Chemical Emissions from Building Materials, Finishes and Furnishings,”
March 2013, Table 2 Office Model and Section 34.1 Allowable Limits for
GREENGUARD Certification Gold.
b. Other accepted third party certifications for flooring compliance are:
• Floorscore
• Green Guard Gold
• Indoor Advantage Gold
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify that surfaces are flat to tolerances acceptable to flooring manufacturer, free of cracks that might telegraph through flooring, clean, dry, and free of curing compounds, JEMEZ DISTRICT OFFICE 09 65 00-6 surface hardeners, and other chemicals that might interfere with bonding of flooring to substrate.
B. Verify that wall surfaces are smooth and flat within the tolerances specified for that type of work, are dust-free, and are ready to receive resilient base.
C. Cementitious Sub-floor Surfaces: Verify that substrates are dry enough and ready for resilient flooring installation by testing for moisture and pH.
1. Test in accordance with Section 09 05 61.
2. Obtain instructions if test results are not within limits recommended by resilient flooring manufacturer and adhesive materials manufacturer.
D. Verify that required floor-mounted utilities are in correct location.
3.2 PREPARATION
A. Prepare floor substrates for installation of flooring in accordance with Section 09 05 61.
3.3 INSTALLATION - GENERAL
A. Starting installation constitutes acceptance of sub-floor conditions.
B. Install in accordance with manufacturer's instructions.
C. Spread only enough adhesive to permit installation of materials before initial set.
D. Fit joints tightly.
E. Set flooring in place, press with heavy roller to attain full adhesion.
F. Where type of floor finish, pattern, or color are different on opposite sides of door, terminate flooring under centerline of door.
G. Install edge strips at unprotected or exposed edges, where flooring terminates, and where indicated.
1. Resilient Strips: Attach to substrate using adhesive.
H. Scribe flooring to walls, columns, cabinets, floor outlets, and other appurtenances to produce tight joints.
3.4 SHEET FLOORING
A. Lay flooring with joints and seams parallel to longer room dimensions, to produce minimum number of seams. Lay out seams to avoid widths less than 1/3 of roll width;
match patterns carefully at seams.
B. Double cut sheet at seams.
C. Lay flooring with tightly butted seams, without any seam sealer unless otherwise indicated.
JEMEZ DISTRICT OFFICE 09 65 00-7
D. Finish seams in linoleum by heat welding.
3.5 RESILIENT BASE
A. Fit joints tightly and make vertical. Install in longest lengths possible; maintain minimum dimension of 18 inches between joints.
B. Miter internal corners. At external corners, use premolded units.
C. Install base on solid backing. Bond tightly to wall and floor surfaces.
3.6 STAIR COVERINGS
A. Adhere over entire surface. Fit accurately and securely.
3.7 CLEANING
A. Remove excess adhesive from floor, base, and wall surfaces without damage.
B. Clean and wax in accordance with manufacturer's instructions.
3.8 PROTECTION
A. Prohibit traffic on resilient flooring for 48 hours after installation.
END OF SECTION 09 65 00
JEMEZ DISTRICT OFFICE 09 65 00-8
SECTION 09 68 13
TILE CARPETING
JEMEZ DISTRICT OFFICE 09 68 13-1
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Carpet tile, fully adhered.
1.2 REFERENCE STANDARDS
A. ASTM D2859 - Standard Test Method for Ignition Characteristics of Finished Textile
Floor Covering Materials.
B. ASTM E648 - Standard Test Method for Critical Radiant Flux of Floor-Covering
Systems Using a Radiant Heat Energy Source.
C. ASTM F710 - Standard Practice for Preparing Concrete Floors to Receive Resilient
Flooring.
D. ASTM F2170 - Standard Test Method for Determining Relative Humidity in Concrete
Floor Slabs Using In-Situ Probes.
1.3 SUBMITTALS
A. See Section 01 33 00 - Submittal Procedures.
B. Product Data: Provide data on specified products, describing physical and performance characteristics; sizes, patterns, colors available, and method of installation.
C. Samples: Submit two carpet tiles illustrating color and pattern design for each carpet color selected.
D. Manufacturer's Installation Instructions: Indicate special procedures and perimeter conditions requiring special attention.
E. Maintenance Data: Include maintenance procedures, recommended maintenance materials, and suggested schedule for cleaning.
F. EPD (Environmental Product Declaration) 3.5.1.2 Path B: Prescriptive Path Option 1
Environmental Product Declaration
a. Submit product data or other published information verifying that this product has an
EPD. Submit in accordance with Section 018113, Green Globes Submittals Forms and
– 3.5 MATERIALS AND RESOURCES credit 3.5.1.2
Environmental Product Declarations.
The Following third party certifications are compliant with credits in section 3.5 of the
Green Globes reference guide:
• NSF/ANSI 140: Sustainability Assessment for Carpet
JEMEZ DISTRICT OFFICE 09 68 13-2
• NSF/ANSI 332: Sustainability Assessment for Resilient Flooring
• NSF/ANSI 342: Sustainability Assessment for Wallcovering Products
• NSF/ANSI 336: Sustainability Assessment for Commercial Furnishings Fabric
• Sustainable Minds (SM) Transparency ReportTM Program
• ANSI/NSC 373: Sustainable Production of Natural Dimension Stone
• ANSI/BIFMA e3-2014e: Furniture Sustainability Standard
• ANSI A138.1 Green Squared-American National Standard Specifications for
Sustainable Ceramic Tiles, Glass Tiles, and Tile Installation
Materials.
• UL 100: Standard for Sustainability for Gypsum Boards and Panels
• UL 102: Standard for sustainability for Swinging Door Leafs
• UL (STP) 106: Sustainability for Luminaires
• UL (STP) 115: Thermal Insulation
b. Include information Contractor Materials Calculator.
G. Source Control and Measurement of Indoor Pollutants Volatile Organic Compounds
Flooring (3.7.2.1.2 and 3.7.2.1.4)
a. Submit product data or other published information verifying compliance with VOC emissions results are determined by California Department of Public Health (CDPH)
“Standard Method for the Testing and Evaluation of Volatile Organic Chemical
Emissions from Indoor Sources Using
Environmental Chambers,” V 1.1, 2010, Standard Private Office Scenario or VOC emission results are determined by UL 2821 “GREENGUARD Certification Program
Method for Measuring and Evaluating Chemical Emissions from Building Materials, Finishes and Furnishings,” March 2013, Table 2 Office Model and Section 34.1
Allowable Limits for GREENGUARD Certification Gold.
b. Other accepted third party certifications for flooring compliance are:
• Floorscore
• Green Guard Gold
• Indoor Advantage Gold
c. Include information on Contractor Source Control and Measurement of Indoor
Pollutants Materials Calculator.
JEMEZ DISTRICT OFFICE 09 68 13-3
1.4 CLOSEOUT
A. Maintenance Materials: Furnish the following for Owner's use in maintenance of project.
1. Extra Carpet Tiles: Quantity equal to 5 percent of total installed of each color and pattern installed.
B. Warranty: Special warranty for carpet tiles: manufacturer agrees to repair or replace components of carpet tile installation that fail in materials or workmanship within warranty period.
1. Warranty period: Manufacturer's standard term.
1.5 QUALITY ASSURANCE
A. Installer Qualifications: Company specializing in installing carpet tile with minimum three years documented experience and approved by carpet tile manufacturer.
1.6 DELIVERY, STORAGE, AND HANDLING
A. Deliver carpeting materials in original mill protective wrapping, with mill register numbers and tags attached.
B. Store inside, in well ventilated area, protected from weather, moisture, and soiling.
1.7 FIELD CONDITIONS
A. Stage materials in area of installation for minimum period of 24 hours prior to installation.
B. Maintain minimum 70 degrees F ambient temperature 24 hours prior to, during and 24 hours after installation.
C. Ventilate installation area during installation and for 72 hours after installation.
D. Do not commence with carpet installation until painting and finishing work is complete and ceilings and overhead work has been tested, approved, and completed.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Acceptable Manufacturers:
1. Basis of Design Product: Reclaim Series Carpet Tiles by Interface, LLC
2. Substitutions: To be approved by CO only. For substitutions contractor to show that proposed product meets all salient and performative qualities of specified carpet, including:
a. Color variation within tiles
b. Number of colorways available within overall line
JEMEZ DISTRICT OFFICE 09 68 13-4
c. Colorways that are specifically designed by manufacturer to be used together within 1 field of carpet.
d. Modularity
e. Tile size
f. Material
g. Recycled content
2.2 ACCESSORIES
A. Sub-Floor Filler: White premix latex; type recommended by flooring material manufacturer.
B. Non-Metallic Edge Strips: Extruded or molded heavy duty vinyl or rubber type; 1-1/2 inch wide, with minimum 2 inch wide anchorage flange; colors selected by Architect from manufacturer's standards.
C. Miscellaneous Materials: Provide other items recommended by carpet manufacturer and installer for the indicated conditions of carpet use, and as required for complete installation.
2.3 EPD (Environmental Product Declaration) 3.5.1.2 Path B:
A. Prescriptive Path Option 1 Environmental Product Declaration
Preference should be given to materials/products that meet the requirements for the
Green Globes credit 3.5.2.2 Path B: Prescriptive Path for Interior Fit-outs.
B. Source Control and Measurement of Indoor Pollutants Volatile Organic Compounds
Flooring (3.7.2.1.2 and 3.7.2.1.4)
Flooring: (select applicable)
- Carpet in this section must meet the requirements of the California Department of
Public Health (CDPH) “Standard Method for the Testing and Evaluation of Volatile
Organic Chemical Emissions from Indoor Sources Using Environmental Chambers,” V
1.1, 2010, Standard Private Office Scenario or VOC emission results are determined by
UL 2821 “GREENGUARD Certification Program Method for Measuring and
Evaluating Chemical Emissions from Building Materials, Finishes and Furnishings,”
March 2013, Table 2 Office Model and Section 34.1 Allowable Limits for
GREENGUARD Certification Gold.
b. Other accepted third party certifications for flooring compliance are:
• Floorscore
• Green Guard Gold
• Indoor Advantage Gold
JEMEZ DISTRICT OFFICE 09 68 13-5
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify that sub-floor surfaces are smooth and flat within tolerances specified for that type of work and are ready to receive carpet tile.
B. Verify that sub-floor surfaces are dust-free and free of substances that could impair bonding of adhesive materials to sub-floor surfaces.
C. Cementitious Sub-floor Surfaces: Verify that substrates are dry enough and ready for flooring installation by testing for moisture and pH.
1. Test in accordance with Section 09 05 61.
2. Obtain instructions if test results are not within limits recommended by flooring material manufacturer and adhesive materials manufacturer.
D. Verify that required floor-mounted utilities are in correct location.
3.2 PREPARATION
A. Prepare floor substrates for installation of flooring in accordance with Section 09 05 61.
3.3 INSTALLATION
A. Starting installation constitutes acceptance of sub-floor conditions.
B. Install carpet tile in accordance with manufacturer's instructions.
C. Blend carpet from different cartons to ensure minimal variation in color match.
D. Cut carpet tile clean. Fit carpet tight to intersection with vertical surfaces without gaps.
E. Lay carpet tile in indicated pattern, with pile direction alternating to next unit, set parallel to building lines unless otherwise indicated on Drawings.
F. Locate change of color or pattern between rooms under door centerline.
G. Fully adhere carpet tile to substrate.
H. Trim carpet tile neatly at walls and around interruptions.
I. Complete installation of edge strips, concealing exposed edges.
3.4 CLEANING
A. Remove excess adhesive without damage, from floor, base, and wall surfaces.
B. Clean and vacuum carpet surfaces.
END OF SECTION 09 68 13
JEMEZ DISTRICT OFFICE 09 68 13-6
SECTION 09 72 00
WALL COVERINGS
JEMEZ DISTRICT OFFICE 09 72 00-1
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Surface preparation and prime painting.
B. Wall covering and borders.
1.2 REFERENCE STANDARDS
1.3 SUBMITTALS
A. See Section 01 33 00 - Submittal Procedures
B. Product Data: Provide data on wall covering and adhesive.
C. Shop Drawings: Indicate wall elevations with seaming layout.
D. Samples: Submit two samples of wall covering illustrating color, finish, and texture.
E. Manufacturer's Installation Instructions: Indicate special procedures and perimeter conditions requiring special attention.
F. Maintenance Data: Submit data on cleaning, touch-up, and repair of covered surfaces.
1.4 CLOSEOUT
A. Maintenance Materials: Furnish the following for Owner's use in maintenance of project.
1. Extra Wall Covering Materials: 5% []of each color and pattern of wall covering;
store where directed.
2. Package and label each roll by manufacturer, color and pattern, and destination room number.
1.5 QUALITY ASSURANCE
A. Installer Qualifications: Company specializing in performing the type of work specified in this Section with minimum five years of experience.
1.6 DELIVERY, STORAGE, AND HANDLING
A. Deliver materials in original packages or containers clearly labeled to identify manufacturer, brand name, quality and grade, and fire hazard classification.
B. Inspect roll materials at arrival on site, to verify acceptability.
C. Protect packaged adhesive from temperature cycling and cold temperatures.
JEMEZ DISTRICT OFFICE 09 72 00-2
D. Store materials in a well ventilated area protected from weather, moisture, soiling, and extreme temperatures and humidity. Maintain temperature is storage area above 40 degrees F.
E. Protect packaged adhesive from temperature cycling and cold temperatures.
F. Do not store roll goods on end.
1.7 FIELD CONDITIONS
A. Do not apply materials when surface and ambient temperatures are outside the temperature ranges required by the adhesive or wall covering product manufacturer.
B. Maintain these conditions 24 hours before, during, and after installation of adhesive and wall covering.
PART 2 PRODUCTS
2.1 MATERIALS
A. Wall Covering - Type SWF-1: Poplar Bark Wall Covering:
1. Basis of Design Manufacturer: Barkhouse
2. Panel Size: Shingle
3. Grade: Interior
4. Thickenss: 3/8" to 7/16"
5. Color: Poplar Natural Mixed
6. Finish: Flat Poly
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify that substrate surfaces are ready to receive work, and conform to requirements of the wall covering manufacturer.
B. Measure moisture content of surfaces using an electronic moisture meter. Do not apply wall coverings if moisture content of substrate exceeds level recommended by wall covering manufacturer.
C. Verify flatness tolerance of surfaces does not vary more than 1/8 inch in 10 feet nor vary at a rate greater than 1/16 inch/ft.
3.2 PREPARATION
A. Fill cracks in substrate and smooth irregularities with filler; sand smooth.
B. Wash impervious surfaces with tetra-sodium phosphate, rinse and neutralize; wipe dry.
C. Surface Appurtenances: Remove or mask electrical plates, hardware, light fixture trim, escutcheons, and fittings prior to preparing surfaces or finishing.
JEMEZ DISTRICT OFFICE 09 72 00-3
D. Surfaces: Correct defects and clean surfaces that affect work of this Section. Remove existing coatings that exhibit loose surface defects.
E. Marks: Seal with shellac those that may bleed through surface finishes.
F. Apply one coat of primer sealer to substrate surfaces. Allow to dry. Lightly sand smooth.
G. Vacuum clean surfaces free of loose particles.
3.3 INSTALLATION
A. Apply adhesive and wall covering in accordance with manufacturer's instructions.
B. Use wall covering in roll number sequence.
C. Razor trim edges. Do not razor cut on gypsum board surfaces.
D. Apply wall covering smooth, without wrinkles, gaps or overlaps. Eliminate air pockets and ensure full bond to substrate surface. Butt edges tightly.
E. Horizontal seams are not acceptable.
F. Do not seam within 2 inches of internal corners or within 6 inches of external corners.
G. Install wall covering before installation of bases and items attached to or spaced slightly from wall surface.
H. Do not install wall covering more than 1/4 inch below top of resilient base.
I. Cover spaces above and below windows, above doors, in pattern sequence from roll.
J. Remove excess adhesive while wet from seam before proceeding to next wall covering sheet. Wipe clean with dry cloth.
3.4 CLEANING
A. Clean wall coverings of excess adhesive, dust, dirt, and other contaminants.
B. Reinstall wall plates and accessories removed prior to work of this Section.
3.5 PROTECTION
A. Do not permit construction activities at or near finished wall covering areas.
END OF SECTION 09 72 00
JEMEZ DISTRICT OFFICE 09 72 00-4
SECTION 09 77 33
FIBER GLASS REINFORCED PLASTIC (FRP) PANELS
JEMEZ DISTRICT OFFICE 09 77 33-1
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Glass fiber reinforced plastic panels.
B. Accessories and trim.
1.2 REFERENCE STANDARDS
A. ASTM D5319 - Standard Specification for Glass-Fiber Reinforced Polyester Wall and
Ceiling Panels.
B. ASTM E84 - Standard Test Method for Surface Burning Characteristics of Building
Materials.
1.3 SUBMITTALS
A. See Section 01 33 00 - Submittal Procedures.
B. Product Data: Provide data on specified products, describing physical and performance characteristics; including sizes, patterns and colors available; and installation instructions.
C. Samples: Submit two samples illustrating material, color, and surface design of panels.
D. Maintenance Materials: Furnish the following for Government's use in maintenance of project.
E. EPD (Environmental Product Declaration) 3.5.1.2 Path B: Prescriptive Path Option 1
Environmental Product Declaration
a. Submit product data or other published information verifying that this product has an
EPD. Submit in accordance with Section 018113, Green Globes Submittals Forms and
– 3.5 MATERIALS AND RESOURCES credit 3.5.1.2
Environmental Product Declarations.
The Following third party certifications are compliant with credits in section 3.5 of the
Green Globes reference guide:
• NSF/ANSI 140: Sustainability Assessment for Carpet
• NSF/ANSI 332: Sustainability Assessment for Resilient Flooring
• NSF/ANSI 342: Sustainability Assessment for Wallcovering Products
• NSF/ANSI 336: Sustainability Assessment for Commercial Furnishings Fabric
• Sustainable Minds (SM) Transparency ReportTM Program
JEMEZ DISTRICT OFFICE 09 77 33-2
• ANSI/NSC 373: Sustainable Production of Natural Dimension Stone
• ANSI/BIFMA e3-2014e: Furniture Sustainability Standard
• ANSI A138.1 Green Squared-American National Standard Specifications for
Sustainable Ceramic Tiles, Glass Tiles, and Tile Installation
Materials.
• UL 100: Standard for Sustainability for Gypsum Boards and Panels
• UL 102: Standard for sustainability for Swinging Door Leafs
• UL (STP) 106: Sustainability for Luminaires
• UL (STP) 115: Thermal Insulation
b. Include information Contractor Materials Calculator.
1.4 QUALITY ASSURANCE
A. Basis of Design: Specifications are based on panel types by specified basis of design manufacturer and product(s). Panel types manufactured by other acceptable manufacturers are permitted, subject to compliance with specified requirements; and provided that deviations in design, weight, and profile are minor, and do not detract substantially from the indicated design intent.
1.5 DELIVERY, STORAGE, AND HANDLING
A. Store panels flat, indoors, on a clean, dry surface. Remove packaging and allow panels to acclimate to room temperature for 48 hours prior to installation.
PART 2 PRODUCTS
2.1 PANEL SYSTEMS
A. Type A Wall Panels:
1. Panel Size: As indicated on Drawings or necessitated by location context.
2. Panel Thickness: 0.100 (2.5 mm).
3. Surface Design: Embossed.
4. Color: White.
5. Attachment Method: Adhesive only, with trim and sealant in joints.
2.2 MATERIALS
A. Panels: Glass fiber reinforced plastic (FRP), complying with ASTM D5319.
1. Surface Burning Characteristics: Maximum flame spread index of 25 and smoke developed index of 450; when system tested in accordance with ASTM E84.
B. Trim: Vinyl; color coordinating with panel.
JEMEZ DISTRICT OFFICE 09 77 33-3
C. Adhesive: Type recommended by panel manufacturer.
D. Sealant: Silicone; color matching panel.
2.3 EPD (Environmental Product Declaration) 3.5.1.2 Path B:
A. Prescriptive Path Option 1 Environmental Product Declaration
Preference should be given to materials/products that meet the requirements for the
Green Globes credit 3.5.2.2 Path B: Prescriptive Path for Interior Fit-outs.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify existing conditions and substrate flatness before starting work.
B. Verify that substrate conditions are ready to receive the work of this section.
3.2 INSTALLATION - WALLS
A. Install panels in accordance with manufacturer's instructions.
B. Cut and drill panels with carbide tipped saw blades, drill bits, or snips.
C. Apply adhesive to the back side of the panel using trowel as recommended by adhesive manufacturer.
D. Apply panels to wall with seams plumb and pattern aligned with adjoining panels.
E. Install panels with manufacturer's recommended gap for panel field and corner joints.
F. Place trim on panel before fastening edges, as required.
G. Fill channels in trim with sealant before attaching to panel.
H. Install trim with adhesive and screws or nails, as required.
I. Seal gaps at floor, ceiling, and between panels with applicable sealant to prevent moisture intrusion.
J. Remove excess sealant after paneling is installed and prior to curing.
END OF SECTION 09 77 33
JEMEZ DISTRICT OFFICE 09 77 33-4
SECTION 09 91 13
EXTERIOR PAINTING
JEMEZ DISTRICT OFFICE 09 91 13-1
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Surface preparation.
B. Field application of paints, stains, and varnishes.
1.2 DEFINITIONS
A. Conform to ASTM D16 for interpretation of terms used in this Section.
B. Gloss Ratings: ASTM D523; on 85 and 60 degree gloss meters:
1. Flat: 0 to 15 (85 degree gloss meter).
2. Eggshell: 5 to 20 (60 degree gloss meter).
3. Satin: 15 to 35 (60 degree gloss meter).
4. Semi-Gloss: 30 to 65 (60 degree gloss meter).
5. Gloss (High): 65 and Greater (60 degree gloss meter).
1.3 REFERENCE STANDARDS
A. ASTM D16 - Standard Terminology for Paint, Related Coatings, Materials, and
Applications.
B. ASTM D4442 - Standard Test Methods for Direct Moisture Content Measurement of
Wood and Wood-Base Materials.
C. SSPC-SP 1 - Solvent Cleaning.
D. SSPC-SP 2 - Hand Tool Cleaning.
E. SSPC-SP 6 - Commercial Blast Cleaning.
1.4 SUBMITTALS
A. See Section 01 33 00 - Submittal Procedures.
B. Product Data: Provide complete list of products to be used, with the following information for each:
1. Manufacturer's name, product name and/or catalog number, and general product category (e.g. "alkyd enamel").
2. Cross-reference to specified paint system(s) product is to be used in; include description of each system.
3. Manufacturer's installation instructions.
C. Samples: Submit two painted samples, illustrating selected colors and textures for each color and system selected with specified coats cascaded. Submit on aluminum sheet, 8 x 10 inch in size.
JEMEZ DISTRICT OFFICE 09 91 13-2
D. Manufacturer's Instructions: Indicate special surface preparation procedures and substrate conditions requiring special attention.
E. EPD (Environmental Product Declaration) 3.5.1.2 Path B: Prescriptive Path Option 1
Environmental Product Declaration
a. Submit product data or other published information verifying that this product has an
EPD. Submit in accordance with Section 018113, Green Globes Submittals Forms and
– 3.5 MATERIALS AND RESOURCES credit 3.5.1.2
Environmental Product Declarations.
The Following third party certifications are compliant with credits in section 3.5 of the
Green Globes reference guide:
• NSF/ANSI 140: Sustainability Assessment for Carpet
• NSF/ANSI 332: Sustainability Assessment for Resilient Flooring
• NSF/ANSI 342: Sustainability Assessment for Wallcovering Products
• NSF/ANSI 336: Sustainability Assessment for Commercial Furnishings Fabric
• Sustainable Minds (SM) Transparency ReportTM Program
• ANSI/NSC 373: Sustainable Production of Natural Dimension Stone
• ANSI/BIFMA e3-2014e: Furniture Sustainability Standard
• ANSI A138.1 Green Squared-American National Standard Specifications for
Sustainable Ceramic Tiles, Glass Tiles, and Tile Installation
Materials.
• UL 100: Standard for Sustainability for Gypsum Boards and Panels
• UL 102: Standard for sustainability for Swinging Door Leafs
• UL (STP) 106: Sustainability for Luminaires
• UL (STP) 115: Thermal Insulation
b. Include information Contractor Materials Calculator.
1.5 CLOSEOUT
A. Maintenance Materials: Furnish the following for Government's use in maintenance of project.
1. Extra Paint and Finish Materials: 1 gallon of each color; from the same product run, store where directed.
2. Label each container with color in addition to the manufacturer's label.
JEMEZ DISTRICT OFFICE 09 91 13-3
1.6 QUALITY ASSURANCE
A. Applicator Qualifications: Company specializing in performing the type of work specified with minimum three years experience.
B. Basis of Design: Specifications are based on paint types and systems by specified basis of design manufacturer. Paint types and systems manufactured by other acceptable manufacturers are permitted, subject to compliance with specified requirements; and provided that deviations in formulation, compatibility, and performance are minor, and do not detract substantially from the indicated design intent.
1.7 DELIVERY, STORAGE, AND HANDLING
A. Deliver products to site in sealed and labeled containers; inspect to verify acceptability.
B. Container Label: Include manufacturer's name, type of paint, brand name, lot number, brand code, coverage, surface preparation, drying time, cleanup requirements, color designation, and instructions for mixing and reducing.
C. Paint Materials: Store at minimum ambient temperature of 45 degrees F and a maximum of 90 degrees F, in ventilated area, and as required by manufacturer's instructions.
1.8 FIELD CONDITIONS
A. Do not apply materials when surface and ambient temperatures are outside the temperature ranges required by the paint product manufacturer.
B. Follow manufacturer's recommended procedures for producing best results, including testing of substrates, moisture in substrates, and humidity and temperature limitations.
C. Do not apply exterior paint and finishes during rain or snow, or when relative humidity is outside the humidity ranges required by the paint product manufacturer.
D. Minimum Application Temperatures for Latex Paints: 50 degrees F for exterior; unless required otherwise by manufacturer's instructions.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Provide paints and finishes used in any individual system from the same manufacturer;
no exceptions.
B. Acceptable Manufacturers:
1. Basis of Design Manufacturer: Sherwin-Williams Company: www.sherwin-williams.com.
2. Comex Group; Kwal Paint: www.thecomexgroup.com.
3. Glidden Professional, a product of PPG Architectural Coatings:
www.gliddenprofessional.com.
JEMEZ DISTRICT OFFICE 09 91 13-4
4. ICI Dulux Paint: www.dulux.com.
C. Acceptable Manufacturers - Primers and Sealers: Same manufacturer as top coats.
2.2 PAINTS AND FINISHES - GENERAL
A. Paints and Finishes: Ready mixed, unless required to be a field-catalyzed paint.
1. Provide paints and finishes of a soft paste consistency, capable of being readily and uniformly dispersed to a homogeneous coating, with good flow and brushing properties, and capable of drying or curing free of streaks or sags.
2. Provide materials that are compatible with one another and the substrates indicated under conditions of service and application, as demonstrated by manufacturer based on testing and field experience.
3. Supply each paint material in quantity required to complete entire project's work from a single production run.
4. Do not reduce, thin, or dilute paint or finishes or add materials unless such procedure is specifically described in manufacturer's product instructions.
B. Sheens: Provide the sheens specified; where sheen is not specified, sheen will be selected later by CO from the manufacturer's full line.
C. Colors: As scheduled on Drawings.
2.3 PAINT SYSTEMS
A. Paint E-OP - Exterior Surfaces to be Painted, Unless Otherwise Indicated: Including concrete, concrete masonry units, brick, fiber cement siding, primed wood, and primed metal.
1. Two top coats and one coat primer.
2. Top Coat(s): Exterior Ferrous Metals, Primed, Latex, 2-coat:
a. Touch-up with rust-inhibitive primer recommended by top coat manufacturer.
b. Semi-gloss: Two coats of latex enamel.
1) Acceptable Product: Sherwin-Williams Pro Industrial Acrylic, B66-650
Series.
3. Top Coat Sheen:
a. Semi-Gloss: MPI gloss level 5; use this sheen at all locations unless otherwise indicated or specified.
4. Primers: As recommended by top coat manufacturer for specific substrate.
2.4 ACCESSORY MATERIALS
A. Accessory Materials: Provide primers, sealers, cleaning agents, cleaning cloths, sanding materials, and clean-up materials as required for final completion of painted surfaces.
B. Patching Material: Latex filler.
C. Fastener Head Cover Material: Latex filler.
JEMEZ DISTRICT OFFICE 09 91 13-5
2.5 EPD (Environmental Product Declaration) 3.5.1.2 Path B:
A. Prescriptive Path Option 1 Environmental Product Declaration
Preference should be given to materials/products that meet the requirements for the
Green Globes credit 3.5.2.2 Path B: Prescriptive Path for Interior Fit-outs.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify that surfaces are ready to receive work as instructed by the product manufacturer.
B. Examine surfaces scheduled to be finished prior to commencement of work. Report any condition that may potentially effect proper application.
C. Test shop-applied primer for compatibility with subsequent cover materials.
D. Measure moisture content of surfaces using an electronic moisture meter. Do not apply finishes unless moisture content of surfaces are below the following maximums:
1. Exterior Plaster and Stucco: 12 percent.
2. Masonry, Concrete, and Concrete Masonry Units: 12 percent.
3. Exterior Wood: 15 percent, measured in accordance with ASTM D4442.
3.2 PREPARATION
A. Clean surfaces thoroughly and correct defects prior to application.
B. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.
C. Remove or mask surface appurtenances, including electrical plates, hardware, light fixture trim, escutcheons, and fittings, prior to preparing surfaces for finishing.
D. Seal surfaces that might cause bleed through or staining of topcoat.
E. Remove mildew from impervious surfaces by scrubbing with solution of tetra-sodium phosphate and bleach. Rinse with clean water and allow surface to dry.
F. Exterior Gypsum Board: Fill minor defects with exterior filler compound. Spot prime defects after repair.
G. Exterior Plaster: Fill hairline cracks, small holes, and imperfections with exterior patching plaster. Make smooth and flush with adjacent surfaces. Wash and neutralize high alkali surfaces.
H. Galvanized Surfaces:
1. Remove surface contamination and oils and wash with solvent according to SSPC-
SP 1.
JEMEZ DISTRICT OFFICE 09 91 13-6
2. Prepare surface according to SSPC-SP 2.
I. Ferrous Metal:
1. Solvent clean according to SSPC-SP1.
2. Shop-Primed Surfaces: Sand and scrape to remove loose primer and rust. Feather edges to make touch-up patches inconspicuous. Clean surfaces with solvent.
Prime bare steel surfaces. Re-prime entire shop-primed item.
3. Remove rust, loose mill scale, and other foreign substances using using methods recommended in writing by paint manufacturer and blast cleaning according to
SSPC-SP 6 "Commercial Blast Cleaning". Protect from corrosion until coated.
J. Exterior Wood Surfaces to Receive Opaque Finish: Remove dust, grit, and foreign matter. Seal knots, pitch streaks, and sappy sections. Fill nail holes with tinted exterior calking compound after prime coat has been applied. Back prime concealed surfaces before installation.
K. Metal Doors to be Painted: Prime metal door top and bottom edge surfaces.
3.3 PAINTING AND COATING - GENERAL
A. Scope: Finish exterior surfaces exposed to view, unless fully factory-finished and unless otherwise indicated, including the following:
1. Exposed surfaces of steel lintels and ledge angles.
2. Items specifically indicated on Drawings to receive paint finish.
B. Do Not Paint or Finish the Following Items:
1. Items factory-finished unless otherwise indicated; materials and products having factory-applied primers are not considered factory finished.
2. Items indicated to receive other finishes.
3. Items indicated to remain unfinished.
4. Fire rating labels, equipment serial number and capacity labels, and operating parts of equipment.
5. Non-metallic roofing and flashing.
6. Stainless steel, anodized aluminum, bronze, terne coated stainless steel, zinc, and lead.
7. Marble, granite, slate, and other natural stones.
8. Floors, unless specifically indicated.
9. Brick, glass unit masonry, architectural concrete, cast stone, integrally colored plaster and stucco.
10. Glass.
3.4 APPLICATION
A. Exterior Wood to Receive Opaque Finish: If final painting must be delayed more than
2 weeks after installation of woodwork, apply primer within 2 weeks and final coating within 4 weeks.
B. Apply products in accordance with manufacturer's written instructions.
JEMEZ DISTRICT OFFICE 09 91 13-7
C. Do not apply finishes to surfaces that are not dry. Allow applied coats to dry before next coat is applied.
D. Apply each coat to uniform appearance.
E. Vacuum clean surfaces of loose particles. Use tack cloth to remove dust and particles just prior to applying next coat.
F. Reinstall electrical cover plates, hardware, light fixture trim, escutcheons, and fittings removed prior to finishing.
3.5 CLEANING
A. Collect waste material that could constitute a fire hazard, place in closed metal containers, and remove daily from site.
3.6 PROTECTION
A. Protect finishes until completion of project.
B. Touch-up damaged finishes after Substantial Completion.
END OF SECTION 09 91 13
JEMEZ DISTRICT OFFICE 09 91 13-8
SECTION 09 91 23
INTERIOR PAINTING
JEMEZ DISTRICT OFFICE 09 91 23-1
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Surface preparation.
B. Field application of paints, stains, and varnishes.
1.2 DEFINITIONS
A. Conform to ASTM D16 for interpretation of terms used in this Section.
B. Gloss Ratings: ASTM D523; on 85 and 60 degree gloss meters:
1. Flat: 0 to 15 (85 degree gloss meter).
2. Eggshell: 5 to 20 (60 degree gloss meter).
3. Satin: 15 to 35 (60 degree gloss meter).
4. Semi-Gloss: 30 to 65 (60 degree gloss meter).
5. Gloss (High): 65 and Greater (60 degree gloss meter).
1.3 REFERENCE STANDARDS
A. 40 CFR 59, Subpart D - National Volatile Organic Compound Emission Standards for
Architectural Coatings; U.S. Environmental Protection Agency.
B. ASTM D16 - Standard Terminology for Paint, Related Coatings, Materials, and
Applications.
C. ASTM D4442 - Standard Test Methods for Direct Moisture Content Measurement of
Wood and Wood-Base Materials.
D. SSPC-SP 1 - Solvent Cleaning.
E. SSPC-SP 2 - Hand Tool Cleaning.
F. SSPC-SP 6 - Commercial Blast Cleaning.
G. SSPC-SP 13 - Surface Preparation of Concrete;
1.4 SUBMITTALS
A. See Section 01 33 00 - Submittal Procedures.
B. Product Data: Provide complete list of products to be used, with the following information for each:
1. Manufacturer's name, product name and/or catalog number, and general product category (e.g. "alkyd enamel").
2. Cross-reference to specified paint system(s) product is to be used in; include description of each system.
3. Manufacturer's installation instructions.
JEMEZ DISTRICT OFFICE 09 91 23-2
C. Samples: Submit two painted samples, illustrating selected colors for each color and system selected with specified coats cascaded. Submit on tempered hardboard, 8 x 10 inch in size.
D. Certification: By manufacturer that paints and finishes comply with VOC limits specified.
E. Manufacturer's Instructions: Indicate special surface preparation procedures and substrate conditions requiring special attention.
F. EPD (Environmental Product Declaration) 3.5.1.2 Path B: Prescriptive Path Option 1
Environmental Product Declaration
a. Submit product data or other published information verifying that this product has an
EPD. Submit in accordance with Section 018113, Green Globes Submittals Forms and
– 3.5 MATERIALS AND RESOURCES credit 3.5.1.2
Environmental Product Declarations.
The Following third party certifications are compliant with credits in section 3.5 of the
Green Globes reference guide:
• NSF/ANSI 140: Sustainability Assessment for Carpet
• NSF/ANSI 332: Sustainability Assessment for Resilient Flooring
• NSF/ANSI 342: Sustainability Assessment for Wallcovering Products
• NSF/ANSI 336: Sustainability Assessment for Commercial Furnishings Fabric
• Sustainable Minds (SM) Transparency ReportTM Program
• ANSI/NSC 373: Sustainable Production of Natural Dimension Stone
• ANSI/BIFMA e3-2014e: Furniture Sustainability Standard
• ANSI A138.1 Green Squared-American National Standard Specifications for
Sustainable Ceramic Tiles, Glass Tiles, and Tile Installation
Materials.
• UL 100: Standard for Sustainability for Gypsum Boards and Panels
• UL 102: Standard for sustainability for Swinging Door Leafs
• UL (STP) 106: Sustainability for Luminaires
• UL (STP) 115: Thermal Insulation
b. Include information Contractor Materials Calculator.
JEMEZ DISTRICT OFFICE 09 91 23-3
G. Source Control and Measurement of Indoor Pollutants Volatile Organic Compounds
Paints and Coatings (3.7.2.1.3) :
a. For paints and coatings applied on site and inside the weatherproofing system, submit product data or other published information verifying the VOC (Volatile Organic
Compound) content is less than or equal to the allowable VOC content established by the governing standards.
b. Submit product data or other published information verifying compliance with:
• VOC concentration of the product shall not exceed those listed below in grams of
VOC per liter of product as determined by ASTM D6886-03: Standard Test Method for
Speciation of the Volatile Organic Compounds (VOCs) in Low VOC Content
Waterborne Air-Dry Coatings by Gas Chromatography.
• VOC emissions results are determined by either of the following test methods:
Standard Practice for the Testing of Volatile Organic Emissions from Various Sources
Using Small-Scale Environmental Chambers CA/DHS/EHLB/R-174, July 14, 2004 with Addendum 2004-01, October 19, 2004 or GREENGUARD Environmental
Institute: Standard Method for Measuring and Evaluating Chemical Emissions From
Building Materials, Finishes and Furnishings Using Dynamic Environmental Chambers
(GGTM.P066.R8, 10/29/2008). Other accepted third party certifications for paints and coatings compliance are:
• South Coast Air Quality Management District (SCAQMD) Rule 1168 for volatile organic compounds
• EcoLogo (Paints & Adhesives) – Environmental Choice
• Green Seal (Paints & Adhesives)
• GREENGUARD Gold
• Indoor Advantage Gold TM – Scientific Certification Systems
c. Include information on Contractor Source Control and Measurement of Indoor
Pollutants Materials Calculator.
• Total square footage of area(s) to be painted.
• VOC content of specified coating systems.
• Coverage rates of coatings specified (from manufacturer’s data sheet).
• Number of coats specified (primer and topcoats).
• Sheen of each coating based on ASTM D523-08: Standard Test Method for Specular
Gloss.
JEMEZ DISTRICT OFFICE 09 91 23-4
1.5 CLOSEOUT
A. Maintenance Materials: Furnish the following for Government's use in maintenance of project.
1. Extra Paint and Finish Materials: 1 gallon of each color; from the same product run, store where directed.
2. Label each container with color in addition to the manufacturer's label.
1.6 QUALITY ASSURANCE
A. Applicator Qualifications: Company specializing in performing the type of work specified with minimum three years experience.
1.7 DELIVERY, STORAGE, AND HANDLING
A. Deliver products to site in sealed and labeled containers; inspect to verify acceptability.
B. Container Label: Include manufacturer's name, type of paint, brand name, lot number, brand code, coverage, surface preparation, drying time, cleanup requirements, color designation, and instructions for mixing and reducing.
C. Paint Materials: Store at minimum ambient temperature of 45 degrees F and a maximum of 90 degrees F, in ventilated area, and as required by manufacturer's instructions.
1.8 FIELD CONDITIONS
A. Do not apply materials when surface and ambient temperatures are outside the temperature ranges required by the paint product manufacturer.
B. Follow manufacturer's recommended procedures for producing best results, including testing of substrates, moisture in substrates, and humidity and temperature limitations.
C. Do not apply materials when relative humidity exceeds 85 percent; at temperatures less than 5 degrees F above the dew point; or to damp or wet surfaces.
D. Minimum Application Temperatures for Paints: 50 degrees F for interiors unless required otherwise by manufacturer's instructions.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Provide paints and finishes used in any individual system from the same manufacturer;
no exceptions.
B. Acceptable Manufacturers:
1. Basis of Design Manufacturer: Sherwin-Williams Company: www.sherwin-williams.com.
2. Benjamin Moore & Co: www.benjaminmoore.com.
JEMEZ DISTRICT OFFICE 09 91 23-5
3. Comex Group; Kwal Paint: www.thecomexgroup.com.
4. Diamond Vogel Paints: www.diamondvogel.com/#sle.
5. Glidden Professional, a product of PPG Architectural…