6515--MRI/PET Molecular and Anatomic Imaging System To correct NAICS and PSC code

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
36C24E22Q0197
Agency
Veterans Integrated Service Network 4 Veterans Health Administration, Department of Veterans Affairs
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
334510 Electromedical and Electrotherapeutic Apparatus Manufacturing
PSC
6515 Medical And Surgical Instruments, Equipment, And Supplies

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs intends to issue a full and open solicitation on September 1, 2022 seeking a firm fixed price purchase order for a one-year delivery period to provide a combined 9.4 Tesla MRI/PET molecular and anatomic imaging system. The selected contractor must deliver the system to the VA Biomolecular Imaging Center at the Harry S. Truman Memorial Veterans' Hospital in Columbia, Missouri to support traumatic brain injury research. The solicitation will require the system to meet salient characteristics and specifications and be evaluated on the contractor's ability to meet the stated requirements. The response deadline is September 23, 2022.

There is no set-aside designation. The applicable NAICS code is 334510 for medical equipment manufacturing with a 1,250 employee size standard and the FSC/PSC is 6515. The place of performance is the VA facility in Columbia, Missouri. The solicitation amendment extended the response deadline to September 23, 2022 and provided answers to sixteen questions from potential offerors seeking clarification on specifications and capabilities of the imaging system.

Notice text

2 versions

Update #2 · Latest ·

Solicitation 36C24E22Q0197

Questions and answers

Can one company submit two quotes for different products? Are we talking about 2 different cryogen-free 9.4T PET/MRI system?

Will you require a reference list of existing fully functioning sites  using the vendors solutions for 9.4 PET/MR? We definitely would like to see a reference list of installed (or being installed) cryogen-free 9.4T MRI with PET capabilities.

Which application areas will require simultaneous PET/MR? Metabolic/molecular/structural imaging applications.

What application requires that traumatic brain studies on mice and rats accommodate animals up to 2.5kg for MRI-only applications? To accommodate larger animal models such as rabbits. Â

Are there whole body rat applications or is the rat research related primarily to brain research? There are rat brain research as well as whole body research including cardiovascular and abdominal imaging research.

What animal models do you wish to image? Mice, rats, rabbit.

Does you research require dedicated and optimized PET/MR Brain coils for rat and mice that have highest SNR in the brain, minimized attenuation effects for PET and allows for the measurement of the MR based attenuation map in a single bed position? Yes

Does the 600 mT/m gradient need to be available for use in simultaneous PET/MR with no exchange of the main system gradient? Yes.

Since we do not believe that a 120mm ID RF coil can accommodate a 2.5kg. animal should the system requirement include a 140mm ID RF coil? Venders can provide options that meet or exceed the stated system specifications.

Would much higher slew rates of up to 4200 mT/m/s in combination with short ramp times of 150us and strong gradient strength up to 900 mT/m of a mouse & rat brain PET/MR scanner beneficial to achieve better high quality PET/MR imaging results at high fields? Yes, higher performance main gradient systems should be beneficial for better imaging outcome which would have to be demonstrated during acceptance testing. Â Â

Would stronger second order shims of up to 3750 Hz/cm2 in combination with 240 Hz/cm3 Z3 shims of a mouse & rat brain PET/MR scanner be an improvement for high quality high-field fMRI and spectroscopy PET/MR? Stronger second order shims could improve the quality of fMRI and spectroscopy again this would need verification demonstrated during acceptance testing.

Can you please be more precise and clear in the required electronic channel configuration and define more specifically what linear or low noise means? The system must be equipped with two (2) RF transmit channels and eight (8) receive channels.  Linearity and noise amplitude will be a function of vendor provided components. The combination of all system components meeting specifications will determine the final system chosen.

Regarding Low noise narrowband preamplifier please specify how many and which band. We are seeking a system with a minimum of 8 preamplifiers providing operational capabilities at narrowband for 1H and also at broadband frequencies for multi-nuclei.

Regarding the minimum of 2 Linear Pre-amplifiers please clarify why 2 when there are 4 receive channels There are a total of 8 receive channels and 8 pre-amplifiers required.

Minimum of 2 preamplifiers specifically optimized for MRI spectroscopy applications for any of the following nuclei: 31P, 22Na, 13C, 19F, 3He, 17O or 129Xe please clarify why 2 broadband preamplifiers when only 1 X-nuclei is detected We are requesting the system include a minimum of 2 broadband pre-amplifiers for current applications.

16. Do you require a single nucleus X-transmit only coil, or rather a 1H/X coil with active detuning for the X nuclei to allow the use of X-nuclei receive-only coils? We recommend the vendor provide both options with VA choosing optimal configuration.

Update #1 ·

Pre-Solicitation Notice to solicit for a contractor to provide a combined 9.4 Tesla MRI/PET molecular and anatomic imaging system to the at the VA Columbia Missouri Healthcare System at the Harry S.Truman Memorial Veteran Hospital, Research Services located at 800 Hospital Drive, Columbia, MO 65201.

This is not a solicitation. The Department of Veterans Affairs intends to solicit for a Firm Fixed Priced purchase order for a 1-year delivery period. The overall goal is to support traumatic brain injury (TBI) research projects associated with the Truman VA Open Field Blast Core (TVA-OFBC). TVA-OFBC is focused on studying the long-term effects of mild TBI using preclinical models. This technology acquisition will complement and expand the existing Molecular Imaging Technology currently housed within the VA Biomolecular Imaging Center (BIC). The required salient characteristics and specifications required will be listed in the Statement of Work (SOW) that will be included with the Solicitation. The solicitation will be issued as full and open unrestricted competition on or about 9/01/2022. The applicable NAICS code is 334510 with a 1,250 Employee Size Standard. The FSC/PSC is 6515.

Copies of the solicitation will not be available for mailing. All prospective contractors must be registered in the System for Award Management (SAM) prior to award of the contract. Registration may be accomplished at www.sam.gov. Questions concerning this procurement may be directed to the Contracting Officer Ann Marie Stewart at annmarie.stewart@va.gov.

Attachments

Files attached to this notice, newest first
File Type Posted
36C24E22Q0197 0001.docx DOCX document
36C24E22Q0197_2.docx DOCX document

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
6515--MRI/PET Molecular and Anatomic Imaging System Award Award Notice
6515--MRI/PET Molecular and Anatomic Imaging System To correct NAICS and PSC code This notice · Latest solicitation Solicitation
6515--MRI/PET Molecular and Anatomic Imaging System Combined 9. 4 Tesla MRI/PET Molecular and Anatomic Imaging Pre-Solicitation