New Walkerflex® Modular Wiring System Offers Labor Savings Compared To Hard-Wired Systems Walkerflex® Modular Wiring System is a factory assembled connector and cable set system, designed to interface with various power applications: raised floor boxes, service poles, surface raceways, wireways, and convenience outlets. This design, with its plug-n-play feature, provides tremendous wire management flexibility and labor savings vs. traditional pipe and box wiring methods.

The new Walkerflex Modular Wiring System is ideal for use in raised floor systems and in combination with FloorSource™ Raised Floor Boxes. Both products are suited for commercial offices, computer rooms, schools or any facility with a demand for high flexibility in wiring requirements

F E A T U R E S & B E N E F I T S n Modular system design, with flexible metal clad cables that plug into each other. Save up to 60% in labor costs for installation compared to pipe and box or BX and J-box wiring.

n Modular plug-n-play components. Provides system flexibility.

Easily re-use and relocate components. Relocation costs are reduced.

n Pin and sleeve contact design. Provides reliability of electrical connections. Allows “First-to-Make, Last-to-Break” ground terminators which reduces potential electrical hazards.

n Designed for up to a maximum of 6 circuits. Provides a wide variety of wiring configurations, while offering maximum system flexibility.

n 10-Wire systems available. Provides a flexible wiring solution for more demanding workstation power requirements, e.g.

multiple neutral, isolated ground, and up to six circuits.

n Mechanical locking feature with an audible snap. Ensures a solid mechanical connection with maximum contact engagement.

n A system integrator. Interfaces with various wire management solutions including: Service Poles, Tele-Power® Poles, Raised Floor Boxes, and Surface Raceway Systems for additional labor savings and flexibility.

n #10 AWG neutrals incorporated. Addresses nonlinear loads in the electrical environment.

n Made in the USA. Assembled and tested by skilled wiring professionals to meet the job specifications.

n Plenum rated product. Product is suitable for use in plenums in accordance with NEC 300.22(c).

n UL Listed – to U.S. and Canadian safety standards for 20A 120V/208V and 277V/480V systems. Ideal for plug load and lighting applications.

Walkerflex Modular Wiring System in a raised floor installation.

WIREMOLD®

Walkerflex® Modular Wiring System

ED755R14 – Updated April 2015 – For latest specs visit www.legrand.us/wiremold

Prewired AF Series Box Walkerflex Power Adapters, Cable Splitters, and male and female Wire Connectors.

System Layout

Typical workstation layout using Walkerflex products to feed furniture panel and AF Series Raised Floor Box in a raised floor application.

AF Series Raised Floor Box

NDU –

Distribution Unit

NCBS –

Cable Splitter

NCS –

Cable Set

Homerun Cable

NCW Cable Whip

Typical Installation

Cat. No. NCS (Cable Set)

Current Flow Direction

Current Flow Direction

Cat. No. NCBS (Splitter)

Cat. No. NCW (Cable Whip)

Cat. No. NPA (Power Adapter)

Cat. No. NWC (Wire Connector)

Current Flow Direction

Current Flow Direction

Catalog No. Item/Description/Specifications

Prewired Distribution Unit Conversion point from electrical closet to the Walkerflex System. Unit can be prewired to buss bar system or be prewired with home run cable. Consult factory for prewiring home run cable.

Unwired Distribution Unit Conversion point from electrical closet to the Walkerflex System.

Unit is for field wiring.

Receptacle Distribution Unit Prewired receptacle unit that is fed with the flex system.

Furniture Feed Distribution Unit Conversion point from rigid EMT, BX, or other listed manufactured wiring systems to the Walkerflex Modular Wiring System.

Walkerflex System Components

NDU P 2 2 2 WC 6

Identifies the Distribution Unit

NDU = 120V

LDU = 277V

Identifies how unit is wired:

( ) Unwired – No identifier needed (see unwired example above

(P) Prewired

(S) Prewired with a Modular “IN” Feed Connector.

Identifies Number of Neutral Conductors per Connector, Four

(4) Conductors maximum.

All Neutrals

#10 AWG.

Number of Ground Conductors per Connector. Insert “1” for one System Ground or “2” for one System Ground and one Isolated Ground.

“WC” stands for Wire Connector.

Remains constant.

Identifies Number of Power “OUT” Wire Connectors.

Number of Circuits, also number of Hot Conductors per Connector. Insert “1” for single circuit, “2” for two-circuit, “3” for three-circuit, “4” for four-circuit, or “6” for six-circuit.

Example: NDU222WC6

Example: NDUP222WC6

NOTE: All distribution units are wired with #10 AWG wire and a #12 Equipment ground.

NOTE: All distribution units are wired with #10 AWG wire and a #12 Equipment ground.

NOTE: See available wiring configuration options on page 7.

NDU 3 3 2 FF

Identifies the Furniture Feed Distribution Unit.

NDU = 120V

LDU = 277V

Number of Circuits, also number of Hot Conductors.

Insert “1” for single circuit, “2” for two-circuit, “3” for three-circuit, “4” for four-circuit, or “6” for six-circuit.

Number of Ground Conductors.

Insert “1” for one System Ground or “2” for one System Ground and one Isolated Ground.

“FF” stands for Furniture Feed. Remains constant.

Identifies number of Neutral Conductors. Four (4) Conductors maximum.

All Neutrals #10 AWG.

NOTE: Units need to be field wired.

Example: NDU222FF Example: NDU332FF

RECDU 1 1 1

Identifies the Receptacle Distribution Unit.

Remains constant.

Number of Circuits, also number of Hot Conductors.

Insert “1” for single circuit, “2” for two-circuit, “3” for three-circuit, “4” for four-circuit, or “6” for six-circuit.

Number of Ground Conductors. Insert “1” for one System Ground or “2” for one System Ground and one Isolated Ground.

Identifies number of Neutral Conductors. Four (4) Conductors maximum.

All Neutrals #10 AWG.

Example: RECDU111

NOTE: See available wiring configuration options on page 7.

Cable Whip Carries Power from distribution unit to other components in flex system. Standard lengths: 1, 5, 10, 15, 20, 25, 30, 40, and 50 ft. [305mm, 1.52m, 3.05m, 4.57m, 7.62m, 9.14m, 12.19m, and 15.24m]. Consult factory for all other lengths.

Cable Whips have a modular connector on one end and pigtails on the other end.

Coded “M” (male) for power “OUT” or “F” (female) for power “IN”.

Cable Sets Carries power from distribution unit to other components in flex system.

Standard lengths: 1, 5, 10, 15, 25, 30, 40, and 50 ft. [305mm, 1.52m, 3.05m, 4.57m, 7.62m, 9.14m, 12.19m,15.24m]. Consult factory for all other lengths.

Cable set can have a plug on both ends. Coded “M” (Male) on one end (“Power Out”) and coded “F” (Female) on the other end (“Power In”) which allows proper connections.

Female (In)

NCW 1 1 1 A L 10 F

Identifies the Cable Whip.

NCW = 120V

LCW = 277V

Number of Circuits, also number of Hot Conductors, insert “1” for single circuit, “2” for two-circuit, “3” for three-circuit, “4” for four-circuit, or “6” for six-circuit.

Number of Ground Conductors, insert “1” for one System Ground, or “2” for one System Ground and one Isolated Ground.

Identifies Gage of Hot and Ground Conductors.

(A) = #12 AWG

(B) = #10 AWG

“L” stands for Length, remains constant.

Identifies Number of Neutral Conductors, Four (4) Conductors maximum.

All Neutrals

#10 AWG.

Example: NCW111AL10F

Insert “M” for Power Out or “F” for Power In.

Length of MC Cable in feet.

NOTE: See available wiring configuration options on page 7.

Walkerflex System Components (Continued)

2 1/2" [64mm]

3 1/2" [89mm]

1 7/16" [37mm]

3 5/32" [80mm] 5 11/16"

[145mm]

1 1/2" [38mm]

Example: NCS111AL10

Female (In) Male (Out)

Male (Out)

Female (In)

NCS 1 1 1 A L 10

Identifies the Cable Set

NCS = 120V

LCS = 277V

Number of Hot Conductors. Insert “1” for single circuit, “2” for two-circuit, “3” for three-circuit, “4” for four-circuit, or “6” for six-circuit.

Number of Ground Conductors. Insert “1” for one System Ground, or “2” for one System Ground and one Isolated Ground.

Identifies Gage of Hot and Ground Conductors.

(A) = #12 AWG

(B) = #10 AWG

“L” stands for Length, remains constant.

Identifies Number of Neutral Conductors, Four

(4) Conductors maximum.

All Neutrals

#10 AWG.

Length of MC Cable in feet.

Power Adapters All adapters are interface components that connect the flex system to an item that is to be energized, such as raised floor boxes, power poles, convenience outlets and various lighting fixtures. Power adapters are for 120V & 277V, 20A applications with a standard 8' [2.4m] MC cable whip and 12" [305mm] leads on the end.

Not available in 8-10 wire.

Modular Power Adapter All adapters are interface components that connect the flex system to an item that is to be energized, such as raised floor boxes, power poles, convenience outlets and various lighting fixtures. Power adapters are for 120V & 277V, 20A applications with a male "Power Out" head at one end and the power adapter at the other end.

Walkerflex System Components (Continued)

NPA 2 2 2 A L 15

Identifies the Power Adapter

NPA = 120V

LPA = 277V

Number of Circuits, Also Number of Hot Conductors. Insert “1” for single circuit, “2” for two-circuit.

Number of Ground Conductors. Insert “1” for one System Ground, or “2” for one System Ground and one Isolated Ground.

Identifies Gage of Hot and Ground Conductors.

(A) = #12 AWG

(B) = #10 AWG

“L” stands for Length, remains constant.

Identifies Number of Neutral Conductors, Two (2) Conductors maximum.

All Neutrals

#10 AWG.

Length of MC Cable in feet.

Example: NPA222AL15

4 3/32" [104mm]

3 1/16" [78mm]

1 11/32" [34mm]

NOTE: Only available in up to 6-wire configurations.

NOTE: See available wiring configuration options on page 7.

NPA 2 2 2 A L 10 M

Identifies the Power Adapter

No. of Circuits, also No. of Hot Conductors. Insert “1” for single circuit, “2” for two-circuit, “3” for three-circuit.

Number of Ground Conductors. Insert “1” for one System Ground, or “2” for one System Ground and one Isolated Ground.

Identifies Gage of Hot and Ground Conductors.

(A) = #12 AWG

(B) = #10 AWG

“L” stands for Length, remains constant.

Identifies No.

of Neutral Conductors, Two (2) Conductors maximum.

All Neutrals

#10 AWG.

Length of MC Cable in feet.

M = Male Power Out

NPA = 120V

LPA = 277V

Example: NPA222AL10M

NOTE: Only available in up to 6-wire configurations.

Cable Splitter Used to split one or more circuits so that it can be used in more than one direction from a given point.

Power Tap All taps are interface components that connect the flex system to an item that is to be energized, such as raised floor boxes, power poles, and lighting fixtures. Power Taps are for 120V & 277V applications with standard 8" leads on the end. Not available in 8-10 wire configurations.

NFWCS Furniture Whip Cable Adaptor - Adaptor allows connection of customer-provided modular office furniture whip to Walkerflex system. Whip supplied must be a UL listed Office Furnishings Furniture Whip with a 20A, 15V rating. Installation of customer-supplied whip into UL listed Walkerflex system must be corrdinated through Project Services and completed by Wiremold factory team.

Walkerflex System Components (Continued)

NCBS 1 1 1

Identifies the Cable Splitter Unit.

NCBS = 120V

LCBS = 277V

Identifies Number of Neutral Conductors, Four (4) Conductors maximum.

All Neutrals #10 AWG.

Number of Hot Conductors.

Insert “1” for single circuit, “2” for two-circuit, “3” for three-circuit, “4” for four-circuit, or “6” for six-circuit.

3 1/16" [78mm]

4 3/32" [104mm]

1 11/32" [34mm]

3 1/16" [78mm]

6 5/32" [156mm]

1 19/32" [40mm]

Example: NCBS111

Number of Ground Conductors. Insert “1” for one System Ground, or “2” for one System Ground and one Isolated Ground.

NOTE: See available wiring configuration options on page 7.

NPT 18 B 1 1 1

Identifies the Power Tap.

NPT = 120V

LPT = 277V

Identifies Number of Hot Conductors 1 = Single Circuit 2 = Two Circuits 3 = Three Circuits

NFWCS XXXX

Identifies the furniture Whip

Project number assigned by Wiremold Project Services team.

Example: NPT18B111

Identifies the Size of Wires.

18 = #18AWG

12 = #12AWG

Egress Options.

B = Bottom Egress

S = Side Egress

Identifies Number of Neutral Conductors Two (2) Conductors maximum

Identifies Number of Grounds 1 = System Ground

2 = System Ground & Isolated Ground

Walkerflex Wiring Configurations

KEY WIRING WIRING

COLOR CONFIGURATION VOLTAGE H N G

BLACK 111 120V 1 1 1

211 120V 2 1 1 311 120V 3 1 1

ORANGE 112 120V/IG 1 1 2

212 120V/IG 2 1 2

222 120V/IG 2 2 2

NATURAL 221 120V/2N 2 2 1

YELLOW 111 277V 1 1 1

211 277V 2 1 1 311 277V 3 1 1

GREEN 112 277V/IG 1 1 2

212 277V/IG 2 1 2

222 277V/IG 2 2 2

BLUE 221 277V/2N 2 2 1

3-6 WIRE CONFIGURATION 8-10 WIRE CONFIGURATION

KEY WIRING WIRING

COLOR CONFIGURATION VOLTAGE H N G

BLACK 422 120V 4 2 2

ORANGE 442 120V/IG 4 4 2

NATURAL 332 120V 3 3 2

BLUE 631 120V 6 3 1

IVORY 622 120V 6 2 2

Wire Connectors Connectors are used to transition between the distribution units, cable sets, and end devices (floor boxes, poles, or raceway). Standard wire lengths are 8", 12" and 18" [203mm, 305mm, and 457mm].

NOTE: Locking Ring style is only available up to 6 wire configurations.

SNAP RING STYLE

LOCKING RING STYLE

Example: NWC222AL12FS Example: NWC222AL12MS Example: NWC332AL12FS Example: NWC332AL12MS

Example: NWC222AL12FL Example: NWC222AL12ML

Walkerflex System Components

NWC 2 2 2 A L 12 F S

Identifies the Wire Connector.

NWC = 120V

LWC = 277V

Number of Circuits, also number of Hot Conductors. Insert “1” for single circuit, “2” for two-circuit, “3” for three-circuit, “4” for four-circuit, or “6” for six-circuit.

Number of Ground Conductors.

Insert “1” for one System Ground or “2” for one System Ground and one Isolated Ground.

Identifies Gage of Hot and Ground Conductors.

(A) = #12 AWG

(B) = #10 AWG

Identifies Length of Wires (in inches) protruding out of back side of the Connector.

Identifies number of Neutral Conductors.

Four (4), Conductors maximum.

All Neutrals

#10 AWG.

Identifies Power Direction “F” (Female) for Power “IN”, “M” (Male) for Power “OUT”.

Identifies method of securing in device. “L” for Lock Nut, “S” for Snap Ring.

Identifies Length. “L” remains constant.

AF2 & AF4 Prewired Raised Floor Boxes.

DESCRIPTION DIMENSIONS

AF2 AF4

Overall Trim Ring 8 3/4" x 6 3/4" [222mm x 171mm] 9 1/8" x 11" [232mm x 279mm] Module Depth 5" [127mm] 5" [127mm] Panel Opening 8" x 6" [203mm x 152mm] 8" x 10" [203mm x 254mm] Cover Size 7 1/2" x 5" [191mm x 127mm] 7 1/2" x 9 1/2" [191mm x 242mm] Activation Chamber 130 cu in. [2130ml] 220 cu in. [3604ml] User Volume 78.6 cu in. [1288ml] 180 cu in. [2948ml] Total Volume 208.6 cu in. [3418ml] 300 cu in. [4915ml] Knockout Sizes Seven (7) 1/2" & Two (2) 3/4" Seven (7) 1/2" & Two (2) 3/4" Trade Size KOs (Power Side only) Trade Size KOs (Power Side only) Depth Behind Plate 2 3/4" [69.8mm] 2 3/4" [69.8mm] Service Triple Triple Capacity 4 Gangs 8 Gangs Connectivity 6 Ports Unloaded 12 Ports Unloaded Max. Floor Thickness 1 1/2" [38mm] (floor covering included) 1 1/2" [38mm] (floor covering included)

Prewired Raised Floor Boxes AF Series AF2 and AF4 prewired raised floor/raised stage boxes have been designed to work with power, communications and AV devices. The housings are made from die-cast aluminum material with a polycarbonate cover and flange assembly. Comes with a 1 ft. modular Walkerflex power adapter.

AF2 K C 2 111 PA

AF Series:

AF2 or AF4

Cover Color:

K = Black Y = Gray

N = Brown

No. of Receptacles:

2 = 2 Receptacles

4 = 4 Receptacles

Power Delivery System:

111 = 1 Circuit, 1 Neutral, System Ground 222 = 2 Circuits, 2 Neutrals, Isolated Ground

Cover Insert:

C = Carpet Insert T = Tile (No Insert)

Style of Feed:

PA = Power

Adapter

SAF Series SAF prewired shallow raised floor/raised stage boxes have been designed to work with power, communications and AV devices in a minimum 2 1/2" deep floor. The housings are made from formed galvanized steel with a polycarbonate cover and flange assembly. Comes with a 1 ft. modular Walkerflex power adapter.

DESCRIPTION DIMENSIONS

Overall Trim Ring 9 1/8" x 11" [232mm x 279mm]

Module Depth Overall 2.5" [64mm]

Panel Opening 8" x 10" [203mm x 254mm]

Cover Size 7 1/2" x 9 1/2" [191mm x 242mm]

Activation Volume 18.5 cu in. [303ml]

Power Volume 29 cu in. [475ml]

Maximum Floor Panel 1 3/16" [30mm] Thickness with Floor Covering

Knockout Sizes Power – Four (4) 1/2"-3/4" Trade Size Concentric KOs Communication – Two (2) 1/2"-3/4" Trade Size Concentric KOs Depth Behind Plate 2" [51mm] Service Triple Capacity 3 Gangs Connectivity 6 Ports Unloaded

Max. Floor Thickness 1 3/8" [35mm] (floor covering included)

AF2KC2111PA

AF2YC2111PA

AF2NC2111PA

AF2KT2111PA

AF2YT2111PA

AF2NT2111PA

AF2KC2222PA

AF2YC2222PA

AF2NC2222PA

AF2KT2222PA

AF2YT2222PA

AF2NT2222PA

AF2KC4222PA

AF2YC4222PA

AF2NC4222PA

AF2KT4222PA

AF2YT4222PA

AF2NT4222PA

Standard Product Offerings: AF2

AF4KC2111PA

AF4YC2111PA

AF4NC2111PA

AF4KT2111PA

AF4YT2111PA

AF4NT2111PA

AF4KC2222PA

AF4YC2222PA

AF4NC2222PA

AF4KT2222PA

AF4YT2222PA

AF4NT2222PA

AF4KC4222PA

AF4YC4222PA

AF4NC4222PA

AF4KT4222PA

AF4YT4222PA

AF4NT4222PA

Standard Product Offerings: AF4

SAF K C 2 111 PA

SAF Series Cover Color:

K = Black Y = Gray

N = Brown

No. of Receptacles:

2 = 2 Receptacles

Power Delivery System:

111 = 1 Circuit, 1 Neutral, System Ground 222 = 2 Circuits, 2 Neutrals, Isolated Ground

Cover Insert:

C = Carpet Insert T = Tile (No Insert)

Style of Feed:

PA = Power

Adapter

SAFKC2111PA

SAFYC2111PA

SAFNC2111PA

SAFKT2111PA

SAFYT2111PA

SAFNT2111PA

SAFKC2222PA

SAFYC2222PA

SAFNC2222PA

SAFKT2222PA

SAFYT2222PA

SAFNT2222PA

Standard Product Offerings: CESAF

Prewired Raised Floor Boxes (continued)

AC8X8 Series The AC Series Floor Box is an 8" x 8" [203mm x 203mm] single-service, prewired raised floor/raised stage box designed to work with power devices in a minimum 4" [102mm] deep floor. The housings are made from formed galvanized steel with a die-cast aluminum cover and flange assembly. Comes with a 1 ft. modular Walkerflex power adapter.

DESCRIPTION AC8840 DIMENSIONS AC8850 DIMENSIONS

Box Dimensions 8" x 8" x 4" [203mm x 203mm x 102mm] 8" x 8" x 5" [203mm x 203mm x 127mm] Overall Trim Ring 9 1/4" x 9 1/4" [235mm x 235mm] 9 1/4" x 9 1/4" [235mm x 235mm] Module Depth 4" [102mm] 5" [127mm] Panel Opening 8" x 8" [203mm x 203mm] 8" x 8" [203mm x 203mm] Cover Size 7 11/16" x 7 11/16" [195mm x 195mm] 7 11/16" x 7 11/16" [195mm x 195mm] Activation Chamber 63.92 cu in. [1047ml] 97.22 cu in. [1593ml] User Volume 84.34 cu in. [1382ml] 102.22 cu in. [1674ml] Total Volume 152.34 cu in. [2496ml] 199.22 cu in. [3264ml] Knockout Sizes Power – Four (4) 1/2"-3/4" Trade Size Concentric KOs Power – Four (4) 1/2"-3/4" Trade Size Concentric KOs Communication – Two (2) 1/2"-3/4" Trade Size Concentric KOs Communication – Four (4) 1/2"-3/4" Trade Size Concentric KOs Depth Behind Plate 2" [51mm] 2" [51mm] Service Single Single Capacity 4 Gangs 4 Gangs Max. Floor Thickness 2" [51mm] (floor covering included) 2" [51mm] (floor covering included)

AC8840YC2111PA

AC8840YC2222PA

Standard Product Offerings: AC8840

AC 88 50 Y C 2 111 PA

AC Series Cover Size:

88 = 8" x 8" No. of Receptacles:

2 = 2 Receptacles

4 = 4 Receptacles

Power Delivery System:

111 = 1 Circuit, 1 Neutral, System Ground 222 = 2 Circuits, 2 Neutrals, Isolated Ground

Box Depth:

40 = 4" Deep 50 = 5" Deep

Style of Feed:

PA = Power

Adapter

AC8850YC2111PA

AC8850YC2222PA

AC8850YC42222PA

Standard Product Offerings: AC8850

Cover Color:

Y = Gray

Cover Insert:

C = Carpet Insert

AC8840 & AC8850 Prewired Raised Floor Boxes.

AC8X10 Series The AC810 Series Prewired Raised Floor/Raised Stage Boxes. are designed to work with power and communications devices in a minimum 4" [102mm] deep floor. The housings are made from formed galvanized steel with a die-cast aluminum cover and flange assembly. Comes with a 1 ft. modular Walkerflex power adapter.

DESCRIPTION AC8104 DIMENSIONS AC8105 DIMENSIONS

Box Dimensions 8" x 10" x 4" [203mm x 254mm x 102mm] 8" x 10" x 5" [203mm x 254mm x 127mm] Overall Trim Ring 9 1/4" x 11 1/4" [235mm x 286mm] 9 1/4" x 11 1/4" [235mm x 286mm] Module Depth 4" [102mm] 5" [127mm] Panel Opening 8" x 10" [203mm x 254mm] 8" x 10" [203mm x 254mm] Cover Size 7 11/16" x 9 11/16" [195mm x 246mm] 7 11/16" x 9 11/16" [195mm x 246mm] Activation Chamber 76.87 cu in. [1593ml] 111.08 cu in. [1820ml] User Volume 130.09 cu in. [2131ml] 151.97 cu in. [2490ml] Total Volume 201.09 cu in. [3295ml] 262.97 cu in. [4309ml] Knockout Sizes Power – Four (4) 1/2"-3/4" Trade Size Concentric KOs Power – Four (4) 1/2"-3/4" Trade Size Concentric KOs Communication – Four (4) 1/2"-3/4" Trade Size Concentric KOs Communication – Four (4) 1/2"-3/4" Trade Size Concentric KOs Depth Behind Plate 1 3/4" [44mm] 2" [51mm] Service Dual Triple Capacity 6 Gangs 6 Gangs Connectivity 12 Ports Unloaded 18 Ports Unloaded Max. Floor Thickness 2" [51mm] (floor covering included) 2" [51mm] (floor covering included)

AC8104YC2111PA

AC8104YC2222PA

Standard Product Offerings: AC8104

AC 810 5 Y C 2 111 PA

AC Series Cover Size:

810 = 8" x 10" No. of Receptacles:

2 = 2 Receptacles

4 = 4 Receptacles

Power Delivery System:

111 = 1 Circuit, 1 Neutral, System Ground 222 = 2 Circuits, 2 Neutrals, Isolated Ground

Box Depth:

4" = 4" Deep 5" = 5" Deep

Style of Feed:

PA = Power

Adapter

AC8105YC2111PA

AC8105YC2222PA

AC8105YC42222PA

Standard Product Offerings: AC8105

Cover Color:

Y = Gray

Cover Insert:

C = Carpet Insert

AC8104 & AC8105 Prewired Raised Floor Boxes.

Prewired Raised Floor Boxes (continued)

DESCRIPTION CRFB4 DIMENSIONS

Box Dimensions 9 1/2" [241mm] Diameter x 6 5/8" [168mm] Tall Overall Trim Ring 9 1/2" [241mm] Diameter Module Depth 3 3/4" [95mm] Panel Opening 9 1/2" [241mm] Cover Size 9 1/4" [235mm] Diameter Activation Chamber:

Chambers 1 and 2 23.5 cu in. [385ml] Chamber 3 17.5 cu in. [287ml] Chamber 4 32.8 cu in. [538ml] User Volume 30 cu in. [762ml] Total Volume 127.3 cu in. [3233ml] Knockout Sizes Four (4) Concentric 1/2" - 3/4" Trade Size Three (3) Concentric 3/4" - 1" Trade Size One (1) 2" Trade Size Depth Behind Plate 2 1/4" [57mm] Service Triple Capacity 4 Gangs

Communication Device 6 Ports Unloaded

Max. Floor Thickness 2" [51mm] (floor covering included)

AC10105

AC10105 prewired raised floor/ raised stage boxes. The AC10105 is an 10" x 10" [203mm x 254mm] box that has been designed to work with power, communications and audio visual devices in a minimum 5" [127mm] deep floor.

The housings are made from formed galvanized steel with a die-cast aluminum cover and flange assembly. Comes with a 1 ft. modular Walkerflex power adapter.

DESCRIPTION AC10105 DIMENSIONS

Box Dimensions 10" x 10" x 5" [254mm x 254mm x 127mm] Overall Trim Ring 11 1/2" x 11 1/2" [292mm x 292mm] Module Depth 5" [127mm] Panel Opening 10" x 10" [254mm x 254mm] Cover Size 9 5/8" x 9 5/8" [245mm x 245mm] Activation Chamber 115 cu in. [1884ml] User Volume 243 cu in. [3981ml] Total Volume 358 cu in. [5865ml] Knockout Sizes Power – Four (4) 1/2" Trade Size Concentric KOs Communication – Four (4) 1/2"-3/4" Trade Size Concentric KOs Depth Behind Plate 2" [51mm] Service Triple Capacity 6 Gangs

Connectivity 18 Ports Unloaded

Max. Floor Thickness 2" [51mm] (floor covering included)

CRFB Series Prewired round raised floor/wood floor stage boxes. Die-cast aluminum is designed to work with power, communication, and A/V devices in a minimum 6 1/2" [165mm] deep floor. Comes with a 1 foot modular Walkerflex power adapter.

AC 1010 5 Y C 2 111 PA

AC Series Cover Size:

1010 = 10" x 10"

No. of Receptacles:

2 = 2 Receptacles

4 = 4 Receptacles

Power Delivery System:

111 = 1 Circuit, 1 Neutral, System Ground 222 = 2 Circuits, 2 Neutrals, Isolated Ground

Box Depth:

5 = 5" Deep

Style of Feed:

PA = Power

Adapter

AC10105YC2111PA

AC10105YC2222PA

AC10105YC42222PA

Standard Product Offerings: AC10105

Cover Color:

Y = Gray

Cover Insert:

C = Carpet Insert

CRFB4P 2 111 PA

Cover Size:

7 11/16" diameter

No. of Receptacles:

2 = 2 Receptacles

4 = 4 Receptacles

Power Delivery System:

111 = 1 Circuit, 1 Neutral, System Ground 222 = 2 Circuits, 2 Neutrals, Isolated Ground

Style of Feed:

PA = Power

Adapter

CRFB4P2111PA

CRFB4P2222PA

CRFB4P4222PA

Standard Product Offerings: CRFB

NOTE: Covers are sold separately. For more information on cover options, see the next page.

Catalog No./Item Description/Specifications

CRFBBTCBKTR Tamper Resistant Surface Style CRFBBTCBSTR Cover Assembly – Available in die CRFBBTCNKTR cast aluminum with a painted black CRFBBTCBZTR (BK), brass (BS), nickel (NK), bronze CRFBBTCGYTR (BZ) or gray (GY) finish. No cutouts are provided. Lid has built-in key locking feature for tamper resistance.

8CTCGY* Surface Style Cover Assembly – 8CTCBK* Die-cast aluminum cover assembly.

8CTCBS* Cover assembly is available in the 8CTCBZ* following painted finishes: (BK) 8CTCNK* black, (GY) gray, (NK) nickel, (BS) brass, or (BZ) bronze.

8CTGY* Flush Style Cover Assembly – 8CTBK* Die-cast aluminum cover assembly.

8CTBS* Cover assembly is available in the 8CTBZ* following painted finishes: (BK) 8CTNK* black, (GY) gray, (NK) nickel, (BS) brass, or (BZ) bronze.

Catalog No./Item Description/Specifications

CRFBCTCBK Surface Style Cover Assembly – CRFBCTCBS Available in die cast aluminum with CRFBCTCNK a painted black (BK), brass (BS), CRFBCTCBZ nickel (NK), bronze (BZ) or gray CRFBCTCGY (GY) finish. Insert areas allow for tile or carpet cutouts to match finished floor.

CRFBBTCBK Surface Style Cover Assembly – CRFBBTCBS Available in die cast aluminum with CRFBBTCNK a painted black (BK), brass (BS), CRFBBTCBZ nickel (NK), bronze (BZ) or gray CRFBBTCGY (GY) finish. No cutouts are provided for floor coverings.

CRFBCTCBKTR Tamper Resistant Surface Style CRFBCTCBSTR Cover Assembly – Available in die CRFBCTCNKTR cast aluminum with a painted black CRFBCTCBZTR (BK), brass (BS), nickel (NK), bronze CRFBCTCGYTR (BZ) or gray (GY) finish. Lid has built-in key locking feature for tamper resistance. Insert areas allow for tile or carpet cutouts to match finished floor.

CRFB Series Floor Box Covers

9 3/16" [233mm]

9 3/16" [233mm]

9 3/16" [233mm]

9 3/16" [233mm]

9 1/4" [235mm]

9 1/4" [235mm]

* Add suffix “TR” to the end of the part number to indicate tamper-resistant cover assembly. Tamper-resistant versions are secured with a single tamper-resistant screw.

6STCP Series Recessed modular stem assembly – includes 6" [152mm] diameter hole poke-thru stem assembly with a disposable plate and two proprietary 20A duplex receptacles. Devices are recessed 3 1/4" [83mm] below the surface, no cover assembly included. For use with the following cover assemblies (Purchased separately): 6CTC and 6CT series. Comes with 1 ft. modular Walkerflex power adapter.

Included: For Side Compartments: Two (2) proprietary 20 AMP duplex receptacles installed. For Center Compartment: One (1) 6ACT8A Mounting Plate, One (1) 6TRAC Mounting Plate, and One (1) 6SER Mounting Plate. For Bottom Feed Compartment: One (1) 5BLH 1/2-Gang Blank Housing, One (1) 1PTHA 1-Gang Pass-Through Housing Assembly, and One (1) 575CHA 1/2-Gang 3/4" Conduit Housing Assembly.

Evolution™ Series Poke-Thru Devices

16 3/4" [425mm]

6STCPAV Series Recessed modular stem assembly – includes 6" [152mm] diameter hole poke-thru stem assembly with a disposable plate and one proprietary 20A duplex receptacle. Devices are recessed 3 1/4" [83mm] below the surface, no cover assembly included. For use with the following cover assemblies (Purchased separately):

6CTC and 6CT series. Comes with 1 ft. modular Walkerflex power adapter.

Included: For Side Compartments: One (1) proprietary 20 AMP duplex receptacle installed, 682A Device Plate, and 68MAAP Device Plate. For Center Compartment: 6DEC Mounting Plate, 6AAP Mounting Plate, and 6MAAP Mounting Plate For Bottom Feed Compartment: One (1) 5PTHA 1/2-Gang Pass-Through Housing Assembly, One (1) 1PTHA 1-Gang Pass-Through Housing Assembly, and One (1) 575CHA 1/2- Gang 3/4" Conduit Housing Assembly.

6ATCFF Series Recessed modular stem assembly with disposable plate – includes 6" [152mm] diameter hole poke-thru stem assembly with a disposable plate. Devices are recessed 3 1/4" [83mm] below the surface, no cover assembly included. For use with the following cover assemblies (Purchased separately): 6CTC and 6CT series. Comes with 1 ft. modular Walkerflex cable whip.

Included For Bottom Feed Compartment: One (1) 5PTHA 1/2-Gang Pass Through Housing Assembly, One (1) 15FFHA 1 1/2-Gang Pass Through Housing Assembly, One (1) 575CHA 1/2-Gang 3/4" Conduit Housing Assembly

NOTE: Assembled with a scrub water gasket. For use on tile, wood or carpeted covered floors. Maximum floor covering thickness range 1" [25mm], not designed for use on bare concrete or terrazzo finished floors.

16 3/4" [425mm]

16 3/4" [425mm]

NOTE: UL Fire Classified for up to 2 hour rated floors.

6 S TC P 222 PA

Diameter of Poke-Thru Device:

6 = 6" [152mm]

Power Delivery System:

111 = 1 Circuit, 1 Neutral, System Ground 222 = 2 Circuits, 2 Neutrals, Isolated Ground

S = Stem Assembly

Style of Feed:

PA = Power

Adapter

Unit is approved tile, wood, and carpet covered floors

Unit is prewired with 2 20A Duplex Receptacles installed to a Walkerflex connector

NOTE: Receptacles can be wired as a standard or isolated ground devices.

NOTE: UL Fire Classified for up to 2 hour rated floors.

6 S TC P AV 111 PA

Diameter of Poke-Thru Device:

6 = 6" [152mm]

Power Delivery System:

111 = 1 Circuit, 1 Neutral, System Ground

S = Stem Assembly

Style of Feed:

PA = Power

Adapter

Unit is approved tile, wood, and carpet covered floors

Unit is prewired with 1 20A Duplex Receptacle installed to a Walkerflex connector

AV = Audio/ Visual

NOTE: Receptacles are wired as a standard ground device.

NOTE: UL Fire Classified for up to 2 hour rated floors.

6 A TC FF BK 422 CW

Diameter of Poke-Thru Device:

6 = 6" [152mm]

Power Delivery System:

422 = 4 Circuits, 2 Neutrals, Isolated Ground

A = Assembled Unit

Style of Feed:

CW = Cable

Whip

Unit is approved tile, wood, and carpet covered floors

Furniture Feed Style Poke- Thru Device

Color of Cover Assembly = BK = Black GY = Gray BS = Brass NK = Nickel BE = Bronze

NOTE: Assembled with a scrub water gasket. For use on tile, wood or carpeted covered floors. Maximum floor covering thickness range 1" [25mm], not designed for use on bare concrete or terrazzo finished floors.

NOTE: Assembled with a scrub water gasket. For use on tile, wood or carpeted covered floors. Maximum floor covering thickness range 1" [25mm], not designed for use on bare concrete or terrazzo finished floors.

RC9A15TC Series Surface style poke-thru assembly – Prewired 15A quad receptacle with a 1 ft. modular Walkerflex cable whip. Poke-thru unit fits into a 3 1/16" [78 mm] diameter core hole. Unit also includes two openings for pass through capability for one (1) 4-pair category 5e or category 6 cable per opening. Comes with 1 ft.

modular Walkerflex cable whip.

Standard Offerings: RC9A15TCBK111CW, RC9A15TCGY111CW, RC9A15TCBS111CW, RC9A15TCAA111CW, RC9A15TCAL111CW, RC9A15TCAB111CW

NOTE: Assembled with a scrub water gasket. For use on tile, wood or carpeted covered floors. Floor covering thickness range 1/8" to 3/4", not designed for use on bare concrete or terrazzo finished floors.

Evolution™ Series Poke-Thru Devices (continued)

8STCP Series Recessed modular stem assembly with disposable plate – includes 8" diameter hole poke-thru stem assembly with a disposable plate. Devices are recessed 3 1/4" [83mm] below the surface, no cover assembly included. For use with the following cover assemblies (Purchased separately): 8CTC and 8CT series. Comes with 1 ft. modular Walkerflex power adapter.

Included For Bottom Feed Compartments: One (1) 5PTHA 1/2-Gang Pass Through Housing Assembly, One (1) 1PTHA 1-Gang Pass Through Housing Assembly, One (1) 575CHA 1/2-gang 3/4" Conduit Housing Assembly.

16 3/4" [425mm]

16 3/4" [425mm]

NOTE: UL Fire Classified for up to 2 hour rated floors.

8 S TC P 222 PA

Diameter of Poke-Thru Device:

8 = 8" [203mm]

Power Delivery System:

222 = 2 Circuits, 2 Neutrals, Isolated Ground

S = Stem Assembly

Style of Feed:

PA = Power

Adapter

Unit is approved tile, wood, and carpet covered floors

Unit is prewired with 2 20A Duplex Receptacles installed to a Walkerflex connector

RC9A 15 TC BK 111 CW

Surface Style Poke-Thru, Model: RC9A

15 = 15A Quad Power Receptacle

Power Delivery System:

111 = 1 Circuit, 1 Neutral, System Ground

Style of Feed:

CW = Cable

Whip

Unit is approved tile, wood, and carpet covered floors

Color of Cover Assembly:

BK = Black GY = Gray AL = Aluminum BS = Brass AA = All Aluminum AB = All Brass

RC4ATC Series Surface style poke-thru assembly – Two (2) prewired 20A proprietary receptacles with a 1 ft. modular Walkerflex connector. The duplex receptacle on the “A” side is wired to the system ground and the duplex receptacle on the “B” side is wired to isolated ground. The poke-thru unit fits into a 4" [101.6 mm] diameter core hole. Comes with 1 ft. modular Walkerflex power adapter.

Unit also includes:

• Open inserts unloaded to accept discrete keystone connectors from most manufacturers

• Ortronics Tracjacks mounting bezel

• Ortronics Series II communication housing

Standard Offerings: RC4ATCBK222PA, RC4ATCGY222PA, RC4ATCBS222PA, RC4ATCAL222PA, RC4ATCAA222PA, RC4ATCAB222PA

NOTE: Assembled with a scrub water gasket. For use on tile, wood or carpeted covered floors. Floor covering thickness range 1/8" to 3/4", not designed for use on bare concrete or terrazzo finished floors. Modular Jacks sold separately.

16 3/4" [425mm]

RC4 A TC BK 222 PA

Surface Style Poke-Thru, Model: RC4

Power Delivery System:

222 = 2 Circuits, 2 Neutrals, Isolated Ground

A = Assembled Unit

Style of Feed:

PA = Power

Adapter

Unit is approved tile, wood, and carpet covered floors

Color of Cover Assembly:

BK = Black GY = Gray AL = Aluminum BS = Brass AA = All Aluminum AB = All Brass

Surface Style Poke-Thru Devices

NOTE: Assembled with a scrub water gasket. For use on tile, wood or carpeted covered floors. Maximum floor covering thickness range 1" [25mm], not designed for use on bare concrete or terrazzo finished floors.

Surface Style Poke-Thru Devices (continued)

AV3ATC Series Surface style AV poke-thru assembly – One (1) prewired 20A proprietary receptacle with a 1 ft. modular Walkerflex power adapter. The poke-thru unit fits into a 4" [101.6mm] diameter hole.

Unit also includes:

• One (1) Extron adapter to accept Extron MAAP mini architectural adapter plates.

(Extron devices sold separately, only through authorized Extron dealers).

• One (1) Wiremold open system adapter and inserts unloaded to accept discrete keystone connectors from most manufacturers

• One (1) Ortronics Tracjacks adapter

• One (1) Ortronics Series II adapter

Standard Offerings: AVATCBK111PA, AV3ATCGY111PA, AV3ATCBS111PA, AV3ATCAL111PA, AV3ATCAA111PA, AV3ATCAB111PA NOTE: Assembled with a scrub water gasket. For use on tile, wood or carpeted covered floors. Floor covering thickness range 1/8" to 3/4", not designed for use on bare concrete or terrazzo finished floors. Modular Jacks sold separately.

RC7ATC Series Surface style poke-thru assembly – One (1) prewired 20A proprietary receptacle with a 1 ft.

modular Walkerflex cable whip. The Poke-thru unit fits into a 3 1/16" [78 mm] diameter core hole.

Unit also includes:

• One (1) Wiremold open system adapter and inserts unloaded to accept discrete keystone connectors from most manufacturers

• Two (2) Cat. 6 TechChoice discrete keystone modular jacks

• One (1) Ortronics Tracjack adapter

Standard Offerings: RC7ATCBK111CW, RC7ATCGY111CW, RC7ATCBS111CW, RC7ATCAL111CW, RC7ATCAA111CW, RC7ATCAB111CW

NOTE: Assembled with a scrub water gasket. For use on tile, wood or carpeted covered floors. Floor covering thickness range 1/8" to 3/4", not designed for use on bare concrete or terrazzo finished floors.

16 3/4" [425mm]

16 3/4" [425mm]

AV3 A TC BK 111 PA

Surface Style Poke-Thru, Model: AV3

Power Delivery System:

111 = 1 Circuit, 1 Neutral, System Ground

A = Assembled Unit

Style of Feed:

PA = Power

Adapter

Unit is approved tile, wood, and carpet covered floors

Cover Assembly Color:

BK = Black GY = Gray AL = Aluminum BS = Brass AA = All Aluminum AB = All Brass

RC7 A TC BK 111 CW

Surface Style Poke-Thru, Model: RC7

Power Delivery System:

111 = 1 Circuit, 1 Neutral, System Ground

A = Assembled Unit

Style of Feed:

CW = Cable

Whip

Unit is approved tile, wood, and carpet covered floors

Cover Assembly Color:

BK = Black GY = Gray AL = Aluminum BS = Brass AA = All Aluminum AB = All Brass

Furniture Feed Poke-Thru Devices 4FFATC Series Furniture feed style poke-thru assembly – Complete with one-piece finish flange and conduit assembly.

Finish covers flange provided with one (1) 3/4" trade size screw plug opening and one (1) 1 1/4" trade size screw plug opening. The poke-thru unit fits into a 4" [102 mm] diameter hole. Comes with 1 ft. modular Walkerflex cable whip.

Unit also includes:

• One (1) 3/4" trade size conduit adapter.

• One (1) 1 1/4" trade size conduit adapter.

Standard Offerings: 4FFATCBK422CW, 4FFATCGY422CW, 4FFATCBS422CW, 4FFATCAL422CW, NOTE: Assembled with a scrub water gasket.

For use on tile, wood or carpeted covered floors. Floor covering thickness range 1/8" to 3/4", not designed for use on bare concrete or terrazzo finished floors.

16 3/4" [425mm]

4FF A TC BK 422 CW

Power Delivery System:

422 = 4 Circuits, 2 Neutrals, Isolated Ground

A = Assembled Unit

Style of Feed:

CW = Cable

Whip

Unit is approved tile, wood, and carpet covered floors

Cover Assembly Color:

BK = Black GY = Gray AL = Aluminum BS = Brass

4FF =

Furniture Feed Style Poke- Thru Device

Surface Style Poke-Thru Series Specifications

I M P O R T A N T !

The above maximum copper cross sectional area values are for each individual power and communication compartment.

DO NOT add values together for any one compartment.

CAUTION! Core bits vary in size from manufacturer to manufacturer:

• Use a 3" [76mm] American made core bit having an outside diameter of 3 1/16" [78mm]. Minimum hole diameter: 3 1/16" [78mm].

• Use a 4" [102mm] American made core bit having an outside diameter of 4 1/16" [103mm]. Minimum hole diameter: 4 1/16" [103mm].

NOTE: Use above values for solid or stranded conductors.

Size Solid #24 .00032 sq. in. [.206mm2] #22 .00050 sq. in. [.322mm2] #14 .00323 sq. in. [2.083mm2] #12 .00512 sq. in. [3.303mm2] #10 .00815 sq. in. [5.258mm2] # 8 .01296 sq. in. [8.361mm2]

Copper Cross Sectional Area of Commonly Used Conductors

Copper Cross Section:

The copper cross-sectional area determines the amount of wire fill capacity in a poke-thru device. Unlike other wire and cable management systems that utilize wire fill capacity, a poke-thru device is UL tested under fire conditions to determine the maximum amount of copper conductors that will pass through a poke-thru device, while maintaining the fire-rating of the floor assembly. All Walker Flush Style Devices are UL Classified to U.S. and Canadian safety standards (see complete marking on product) to accommodate at a maximum rating as follows:

RC7 SERIES

Maximum Allowable Copper Cross-Sectional Area:

RC7 Power Compartment Only = .01536 sq. in. [9.91mm2] RC7 Each Communication Compartment Only = .0040 sq. in. [2.58mm2]

RC9 SERIES

Maximum Allowable Copper Cross-Sectional Area:

RC9 Power Compartment Only = .01536 sq. in. [9.91mm2] RC9 Each Communication Compartment Only = .0040 sq. in. [2.58mm2]

AV3 SERIES

AV3 Power Compartment Only = .01536 sq. in. [9.91mm2] AV3 Communication Compartment Only = .01938 sq. in. [12.503mm2]

RC4 SERIES

RC4 Power Compartment Only = .03072 sq. in. [19.82mm2] RC4 Each Communication Compartment Only = .008 sq. in. [5.16mm2]

Concrete Thickness Min/Max:

1-HOUR RATED FLOOR – 2 1/4" [57mm] min over top of deck (or 3" [76mm] thick reinforced concrete slab) to a maximum of 7 1/2" [191mm].

2-HOUR RATED FLOOR – 3 1/4" [83mm] min over top of deck (or 4" [102mm] thick reinforced concrete slab) to a maximum of 7 1/2" [191mm].

Floor Coverings:

The poke-thru device is fire rated for carpet and wood covered concrete floors, and tile floor coverings 1/8" to 3/4" [3.2mm to 19.1mm] thickness. For floor coverings not listed above, consult factory.

COM50 1/2" Trade Size Conduit Connections

(Sold Separately)

Intumescent Material

3/4" Trade Size EMT Conduit

Trim Flange for Carpet or Tile Concrete Slab

Junction Box

24.5 cu in. [401ml]

Scrub Water Gasket

Retaining Flange

CAUTION: These devices are suitable for 1, 1 1/2, and 2 hour rated floor assemblies as described in the UL Fire Resistance directory for each service.

These devices meet all UL scrub water requirements, but are not suitable for wet or damp locations, or other areas subject to saturation with water or other liquids such as commercial kitchens.

NOTE: The RC7 Series requires a 3" [76mm] cored hole.

(American made core bit having an outside diameter of 3 1/16" [78mm].)

NOTE: The RC9 Series requires a 3" [76mm] cored hole.

(American made core bit having an outside diameter of 3 1/16" [78mm].)

NOTE: The AV3 Series requires a 4" [102mm] cored hole.

(American made core bit having an outside diameter of 4 1/16" [103mm].)

NOTE: The RC4 Series requires a 4" [102mm] cored hole.

(American made core bit having an outside diameter of 4 1/16" [103mm].)

N O T E S

ED755R14 – Updated April 2015 – For latest specs visit www.legrand.us/wiremold

Electrical Wiring Systems 60 Woodlawn Street West Hartford, CT 06110 Phone: 1.877.BY.LEGRAND (295-3472) www.legrand.us 570 Applewood Crescent Vaughan, Ontario L4K 4B4 Phone:905.738.9195 www.legrand.ca

© Copyright 2015 Legrand All Rights Reserved

File details come from the government source that posted it.