101418_A-151 Amendment 1.pdf

PDF 416 KB Posted

Attached to
Renovate Operations Building 2A - Scotia, NY
Solicitation number
W50S8J-21-R-0004
Issued by

About this file

This document package includes a federal contract solicitation and related architectural drawings. The solicitation is for renovation work at Operations Building 2A located at the Scotia, New York Army National Guard base. Interested contractors must attend a mandatory pre-proposal site visit and conference scheduled for April 28, 2021 at 10:00 AM to register and view the building. Due to COVID-19 precautions, attendance is limited to two representatives per company and masks are required. Proposals are due by May 18, 2021 as outlined in the Standard Form 1442 included with the solicitation. The architectural drawings depict the existing ground floor ceiling plan and include notes specifying ceiling materials, lighting fixtures, HVAC components, and other finishes to match existing conditions. Renovation work will be conducted in scope of work Area 3 as designated on drawing A-011.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GYPSUM BOARD - PAINT

RECESSED LIGHT/ SUSPENDED CAN LIGHT

10' - 0" CEILING HEIGHT ABOVE FINISH FLOOR

ELEVATION IN BRACKETS ( X' - X") INDICATES

PROJECTION ELEVATION

HVAC AIR SUPPLY GRILLE

STRUCTURAL STEEL BEAM - PAINT

EXPOSED CEILING WALL MOUNTED EXTERIOR LIGHT FIXTURE

EXTERIOR FIXTURE

OTS

EXIT SIGN

OPEN TO STRUCTURE-PAINTED

1' x 4' LIGHT FIXTURE - SUSPENDED

2' x 4' LIGHT FIXTURE - RECESSED

CEILING LEGEND:

2' x 4' ACOUSTICAL CEILING TILE

STRIP LIGHT - RECESSED

HVAC AIR SUPPLY GRILLE

GENERAL REFLECTED CEILING PLAN NOTES:

1.

2.

3.

4.

5.

6.

7.

FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND

ABBREVIATIONS REFER TO SHEET AG001.

ARCHITECTURAL CEILING PLANS INDICATE DIMENSIONING AND

PLACEMENT OF VARIOUS CEILING MOUNTED DEVICES. REFER TO

MEP DRAWINGS AND SPECIFICATIONS FOR ALL OTHER INFORMATION

FOR MEP SYSTEMS INCLUDING BUT NOT LIMITED TO FIRE SUPPRESSION,

FIRE ALARM DEVICES, SECURITY DEVICES, EXIT DEVICES, DIFFUSERS,

LIGHTING, LIGHTING CONTROL DEVICES, AND ACCESS PANELS.

CEILING HEIGHTS ARE FOR REFERENCE ONLY AND SHOWN TO HEIGHT

ABOVE FINISH FLOOR UNLESS NOTED OTHERWISE.

NEW CEILINGS WHICH ARE PART OF SCOPE OF WORK AREA 3 NOTED ON

A-011 SHALL MATCH EXISTING CEILING REMOVED. CEILING HEIGHT AND

LOCATION OF CEILING GRID SHALL MATCH EXISTING TO EXTENT POSSIBLE.

GC SHALL COORDINATE NEW HVAC AND FIRE SUPPRESSION WORK WITH

EXISTING LIGHT FIXTURE INSTALLATION TO LIMIT MODIFICATION OF

EXISTING LIGHT DISTRIBUTION IN SPACE. CEILING HEIGHTS ON DRAWINGS

ARE FOR REFERENCE AND EXISTING HEIGHT TAKES PRECEDENT

IN SCOPE OF WORK AREA 3 ALL EXISTING LIGHTING SHALL BE SALVAGED.

REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.

ALL CEILING GRIDS TO BE CENTERED IN ROOMS UNLESS NOTED

OTHERWISE.

ALL LIGHTS, SPEAKERS, SPRINKLERS, SIGNAGE, STROBES AND OTHER

HARDWARE INSTALLED IN TILED CEILING SYSTEMS TO BE CENTERED IN

TILES IN BOTH DIRECTIONS UNLESS NOTED OTHERWISE.

8.

9.

10.

11.

12.

13.

14.

15.

ALIGN ALL CEILING MOUNTED DEVICES.

REFERENCE ROOM FINISH SCHEDULE FOR ADDITIONAL CEILING FINISH

INFORMATION.

CEILING MOUNTED EXIT SIGNS TO BE CENTERED WITHIN DOOR FRAME

OR OPENING. MOUNT 4" OFF FACE OF WALL.

ALL SPRINKLERS, JUNCTION BOXES & SMOKE DETECTORS TO ALIGN

WITH ADJACENT LIGHT FIXTURES, UNLESS NOTED OTHERWISE.

COORDINATE LOCATIONS OF CEILING ACCESS PANELS WITH THE

FINAL LOCATIONS OF MECHANICAL EQUIPMENT AS REQUIRED TO

SERVICE EQUIPMENT AND TO PROVIDE ACCESS TO ALL ABOVE

CEILING EQUIPMENT.

AT CONTINUOUS RUNS OF GYPSUM BOARD ASSEMBLIES, PROVIDE

CONTROL JOINTS AT A MAXIMUM OF (1) PER 50 FEET, NOT TO EXCEED

INDIVIDUAL AREAS OF 2,500 SQUARE FEET.

MOISTURE RESISTANT GYPSUM BOARD SHALL BE USED IN

SOFFITS AND CEILINGS OF RESTROOMS, LOCKER ROOMS,

SHOWERS AND OTHER WET AREAS.

ALL LIGHTING SHALL BE EQUALLY SPACED TO EXTENT POSSIBLE TO

ACCOMODATE EVEN LIGHT LEVELS AT WORKING SURFACES

A

B

C

D

E

F

G

H

I

J

K

L

23456789101112131415

EX1

EX2

EXAEXBEXCEXDEXEEXF

8' - 6"

8' - 6"

8' - 6"

8' - 0"

8' - 0"

8' - 6"

8' - 6"

8' - 6"9' - 0" 9' - 0"

8' - 0"

8' - 6"

8' - 6"

8' - 6"

8' - 6"

10' - 4"

SLOPED CEILING TILE

114' - 7"

103 104

109110

117A

120 121

189A

127B

120A

135136 137138

156B

154 155

158161

189C 189B

163B

163A

166A

167 168 169 170 171

176 177

189D

156C

101A

124A

100B100A

127A

123A

156D

156A

108A

159178

164A

164D

164C

166B

113' - 4"

111' - 10"

BB

AA

2.A 1.A

A-152

EXISTING LIGHT FIXTURES TO BE REINSTALLED

AND DIFFUSERS TO BE REBALANCED OR REUSED

AS INDICATED, REFER TO ELEC AND MECH DWGS.

CONTRACTOR SHALL COORDINATE WITH

SECURITY OFFICER ALL WORK THROUGH THIS

AREA.

EXISTING LIGHT FIXTURES TO

REMAIN IN PLACE, REFER ELEC.

DWGS.

EXISTING LIGHT FIXTURES TO BE

REINSTALLED, REFER TO ELEC DWGS.

8' - 6"

13' - 4"

8' - 6"

8' - 6"

8' - 6"

8' - 6"

8' - 6"

8' - 6"

8' - 6"

8' - 6"

8' - 6"

8' - 0"

8' - 6"

8' - 0"

8' - 0"

8' - 6"

8' - 0"

8' - 6"

8' - 6" 8' - 0" 8' - 6" 8' - 6"

8' - 6" 8' - 6"

10' - 0"

8' - 6"

8' - 6" 8' - 6"

8' - 6"

10' - 0"

8' - 0"

8' - 0"

8' - 0"

8' - 6"

8' - 0"

A B

C D date detailed checkeddesigned ofsheet sheets project contract rev.drawing file

no. date descriptionby ckd

1 1312111098765432

I

H

G

F

E

D

C

B

A

NYANG STRATTON - ADD / ALT BLDG. 2A

VBDZ192001

NEW YORK AIR NATIONAL GUARD

109TH AIRLIFT WING

STRATTON AIR NATIONAL GUARD BASE

SCHENECTADY, NY

10 N PARK PLACE, SUITE 330

MORRISTOWN, NEW JERSEY 07960

973-884-8701

BMCD LICENSE NO 000165

KEYPLAN

E

/1

/2

:0

:0

P

M

Proj. No._A_CENTRAL

A-151

101418

GROUND FLOOR REFLECTED CEILING PLAN

02/20/17

C. REED B. BAKAS

V. VYAS

SCALE IN FEET

0 8' 16' 32'

OVERALL GROUND FLOOR

REFLECTED CEILING PLAN

N O R

TH

A 08/20/19 CR BB TYPE B-1 SUBMITTAL

B 11/15/19 CR BB TYPE B-2 SUBMITTAL

C 03/06/20 CR BB TYPE B-2 SUBMITTAL

TO NGB

D 05/15/20 CR BB TYPE B-3

SUBMIITTAL - IFB

E 05/14/21 VV BB AMENDMENT #1

Sheets
A-151 - GROUND FLOOR REFLECTED CEILING PLAN

File details come from the government source that posted it. Updated .