This document provides details for a federal contract opportunity to construct a trailhead parking lot in Pima County, Arizona. The King Canyon Trailhead project consists of paving approximately 30 parking stalls and two horse trailer stalls, as well as upgrading existing guardrail on Kinney Road. The solicitation number is 6982AF20B000041 and is being advertised as a HUBZone set-aside. The estimated construction period is from December 2020 to February 2021. The project cost is expected to range between $250,000 and $700,000 and is funded through the Federal Highway Administration and Department of Transportation. Bids are due by November 15, 2020 and the selected contractor will be awarded the contract by December 2020.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UTILITY SUMMARY REPORT
AZ FLAP 62(1)
King Canyon Trailhead
Federal Highway Administration Central Federal Lands Highway Division
August 2020
AZ FLAP 62(1) Utility Summary Report
TABLE OF CONTENTS
Coordination
List of Known Utilities within the Project Area (Project Special Contract Requirements) Communication Log
Utility Coordination Plan Set
Utility Coordination FP-14 Standard Specifications
Utility Certification / Utility Relocations
Utility Quality Level Certification
Utility Agreements Appendix (Not Required)
Correspondence Appendix
Section 107. — LEGAL RELATIONS AND RESPONSIBILITY TO THE PUBLIC
107.02 Protection and Restoration of Property and Landscape.
Add the following at the end of this subsection:
List of Known Utilities within the Project Area. The locations of the utilities shown in the plans have been certified to a Quality Level C, with spot locations certified to a Quality Level C according to the CFLHD Utility Data Quality Certification requirements:
http://flh.fhwa.dot.gov/resources/row/cfl/documents/UtilityDataQualityLevelCertification.doc
Table 107-1 Status of Utilities
Company Utility Type Contact Name Contact Information Status
1 Trico Power Robert Quihuis 520-744-2944 (office)
520-591-9429 (cell) rquihuis@trico.coop
2 Centurylink Comm
Robert Campillo
Tony Miller
520-373-4283 robert.campillo@centurylink.com 520-526-1886 (office) 520-300-1349 (cell) tony. miller@centurylink.com
Status 1: The utilities are in conflict with the project and REQUIRE relocation by OTHERS DURING construction.
Status 2: The utilities are in conflict with the project and REQUIRE relocation by the Contractor DURING construction.
Status 3: The utilities are in conflict with the project and REQUIRE relocation BEFORE construction.
Status 4: The utilities are located within the project rights of way but require NO relocation.
Section 204. — EXCAVATION AND EMBANKMENT
Construction Requirements
204.04 Preparation for Roadway Excavation and Embankment Construction. Add the following:
Prior to excavating material and constructing embankments perform the work required in Section 645.
204.05 Conserved Topsoil. Delete the first sentence and substitute the following:
Conserve topsoil from the roadway excavation and from embankment foundation areas to the extent and depth determined by the CO.
204.14 Disposal of Unsuitable or Excess Material. Add the following:
Secure environmental clearances according to Subsection 107.10(d).
Add the following Section:
Section 645. — LOCATING UTILITIES
Description
645.01 This work consists of locating and marking existing utilities by excavating test pits, or using electromagnetic devices, where a physical conflict with proposed construction is suspected and the location is ordered by the CO.
Materials
645.02 Replace the materials excavated or their equivalent in newly furnished materials for restoring the test pit area to its original condition, conforming to the applicable sections of this specification.
Construction Requirements
645.03 General. Exercise special care and extreme caution in order to protect and avoid damage to any utility company facilities. Locate and ensure the safety of all existing utilities. Repair any damage resulting from Contractor's operations at no additional expense to the Government or the utility company.
Locate by minimally intrusive excavation techniques any utility that may be in conflict with the proposed work. If a conflict appears to exist, then notify the CO in writing immediately and provide information on the location and elevation of the utility so that the CO can adjust the proposed work.
645.04 Locating Utility. Use electromagnetic devices to establish alignment of utilities where applicable. When necessary, thread a metal rod through non-metallic utility pipes to locate them. Where neither method is feasible, locate the utility by perpendicular trench or test pits.
645.05 Excavation. To excavate the test pits, clear the test hole area of surface debris. In paved areas, neatly cut and remove existing pavement. Limit the size of the pavement cut to 225 square inches unless otherwise approved by the CO. Excavate by air-vacuum methods or equivalent, keeping the area of disturbance to a minimum.
Excavate the test pit. Limit the nominal diameter of the test pit surface hole to 15 inches, unless otherwise approved. Excavate carefully so as not to disturb utility at it's assumed depth. Expose the utility only to the extent required for identification and data collection purposes. Avoid damage to lines, wrappings, coatings, cathodic protection or other protective coverings and features. Hand-dig as needed to supplement mechanical excavation and to ensure safety. Repeat as necessary to positively expose the utility. Store excavated material for re-use or disposal, as appropriate.
645.06 Record. Measure and record the following information on an appropriately formatted test hole data sheet that includes as a minimum: Elevation of top and/or bottom of the utility tied to the project datum, elevation of existing grade over utility at test-hole, horizontal location referenced to project coordinate datum, field sketch showing horizontal location referenced to a minimum of three (3) swing ties to physical structures existing in the field and shown on the project plans, approximate centerline bearing of utility line, outside diameter of pipe, width of duct banks, and configuration of non-encased multi-conduit systems, utility structure material composition, when reasonably ascertainable, identification of benchmarks used to determine elevations, utility facility condition, pavement thickness and type when applicable, soil type and site conditions, identity of utility owner / operator, and other pertinent information as is reasonably ascertainable from test pit.
Submit 1 copy to the CO within 24 hours.
645.07 Marking. Mark the utility location by flags or paint. Maintain the markings, including repainting faded or damaged markings as ordered by the CO, for the duration of the project, or until the CO determines that the markings are no longer needed.
645.08 Restoration. Backfill with original material, thoroughly compacting the material with a mechanical tamper. Restore aggregate base courses and pavement using equivalent materials and thicknesses. For portland cement concrete pavements, use fast setting concrete. For asphalt concrete pavements, cold patch, resurfacing of pit will be permitted so long as, in the opinion of the CO, it is thoroughly compacted.
645.09 Acceptance. Locating utilities will be evaluated under Subsection 106.02.
Measurement
645.10 Measure the Section 645 items listed in the bid schedule according to Subsection 109.02.
Do not measure locating utilities.
Other related items, including, but not limited to coordination, survey, excavation, recording, backfill, repair, or restoration efforts or materials associated with utility locating and potholing, will not be measured separately for payment, but will be considered subsidiary to the Roadway Excavation pay item.
Communication Log. The following provides a chronological listing of contact made with each Utility Provider.
Arizona Power Service
Date Contact Discussion 06/05/20 thru 07/16/20
Robert Quihuis Discussed project and underground utility location via email
07/28/20 Robert Quihuis Emailed Utility Summary Report
Centurylink
Date Contact Discussion
07/27/20 Robert Campillo Discussed project. Robert will forward Utility Summary to engineering and provide a contact person
07/28/20 Robert Campillo Emailed Utility Summary Report
07/31/20 Tony Miller Received conflict review letter stating no conflicts are anticipated
UTILITY COORDINATION PLAN SET
WaltonG Typewritten Text
UTILITY COORDINATION
SHEET DESCRIPTION
T1 - T2 602-A, B PIPE CULVERT INSTALLATION
T3 602-C PIPE BERM
T4 602-D PIPE CULVERT INSTALLATION
T5 602-E PIPE CORRUGATED METAL END SECTION
T6 604-A CATCH BASIN FLUSH
T7 609-A WHEELSTOP, CONCRETE
V1 KING CANYON TRAILHEAD SIGNING AND MARKING SHEET
V2 W633-7 PERMANENT SIGN INSTALLATION WOOD POSTS
V3-V4 634-B, C PAVEMENT MARKINGS SYMBOLS AND STRIPING DETAILS
W1 TEMPORARY TRAFFIC CONTROL LAYOUT
W2 635-A TEMPORARY TRAFFIC CONTROL ADVANCE SIGNING
W3 - W5 635-6, 10, 14 TEMPORARY TRAFFIC CONTROL
I N D E X T O S H E E T S (CONTINUED FROM SHEET A1)
UTILITY COORDINATION
FP-14 STANDARD SPECIFICATIONS
107.02 Protection and Restoration of Property and Landscape. Follow the requirements of FAR Clause 52.236-9 Protection of Existing Vegetation, Structures, Equipment, Utilities, and Improvements.
Preserve public and private property. Protect monuments established for perpetuating horizontal, vertical, cadastral, or boundary control. When necessary to destroy a monument, reestablish the monument according to applicable state statute or by the direction of the agency or individual who established the monument.
Do not disturb the area beyond the construction limits. Replace trees, shrubs, or vegetated areas damaged by construction operations as directed and at no cost to the Government. Remove damaged limbs of existing trees by an approved arborist.
Do not excavate, remove, damage, alter, or deface archeological or paleontological remains or specimens.
Control the actions of employees and subcontractors on the project to ensure that protected sites are not disturbed or damaged. Should these items be encountered, suspend operations at the discovery site, notify the CO and continue operations in other areas. The CO will inform the Contractor when operations may resume at the discovery site.
When utilities are to be relocated or adjusted, the Government will notify utility owners affected by the relocations or adjustments.
Before beginning work in an area, contact the local utility locating service to mark the utilities. Protect utilities from construction operations. Cooperate with utility owners to expedite the relocation or adjustment of their utilities to minimize interruption of service and duplication of work.
If utility services are interrupted as a result of damage by the construction, immediately notify the utility owner, the CO, and other proper authorities. Cooperate with them until service is restored. Do not work around fire hydrants until provisions for continued service are made and approved by the local fire authority.
Notify the CO if utility work is required. Compensation for the work will be provided under applicable clauses of the contract. Satisfactorily repair damage due to the fault or negligence of the Contractor at no cost to the Government.
UTILITY CERTIFICATION
UTILITY RELOCATIONS
To be completed by the acquiring agency or FHWA, as applicable
General. This certification is a regulatory requirement under 23CFR635 and is an item on the PS&E checklist. The format may be used as a basis of discussion or assignment during the Project Development process.
Project agreements usually require the acquiring agency to be responsible for utility relocations. However, there may be circumstances unique to each project that determines which agency signs the certification.
Refer to the CFLHD Utility Process and Utility Resolution Plan to compile this summary and certification.
I hereby certify that the appropriate research, field investigation, design considerations and coordination with the utility owners on this project has been performed, and resultant utility-related issues have been identified. All utility and related right-of-way issues have been resolved as conforming to 23CFR635.309 (b), or all necessary arrangements have been made for resolution to be undertaken and completed as required for proper coordination with the project’s physical construction schedule. Where it is determined that the completion of such work in advance of the highway construction is not feasible or practical due to economy or special operational problems, there shall be appropriate notification provided in the PS&E advertisement identifying the outstanding utility issues which are to be resolved concurrently with the highway construction. For more detailed information see AZ FLAP 62(1), King Canyon Trailhead Utility Summary Report, dated August 2020.
County Commissioner/FHWA Project Manager Date (or person authorized to sign Utility Certification)
Status of Utilities.
[ ] There are NO known utilities within the project right of way
Company Utility Type Contact Name Contact Information Status
1 Trico Power Robert Quihuis 520-744-2944 (office)
520-591-9429 (cell) rquihuis@trico.coop
2 Centurylink Comm
Robert Campillo
Tony Miller
520-373-4283 robert.campillo@centurylink.com 520-526-1886 (office) 520-300-1349 (cell) tony. miller@centurylink.com
Utility-related Agreements.
Company Agreement Description
1 Trico none
2 Centurylink none
12300 W Dakota Avenue Lakewood Co, 80228
Utility Data Quality Level Certification
UTILITY DATA QUALITY LEVEL CERTIFICATION
To: Dustin Robbins, Project Manager Date: 07/20/20 From: Berwyn Wilbrink, A/E Project Manager Project: AZ FLAP 62(1), King Canyon Trailhead Subject: Utility Data Quality Certification
Quality Level D: I hereby certify that the following tasks have been completed:
Records and Information Research Records Collection Records Review Include Aerial or Ground-Mounted Facilities Compilation and Presentation of Data
Quality Level C: I hereby certify that the following tasks have been completed:
Inclusive of QL D Tasks Identification of Surface Utility Features Include Aerial or Ground-Mounted Facilities Surveys Correlation, Interpretation, and Presentation of' data, Resolution of Discrepancies
Quality Level B: I hereby certify that the following tasks have been completed:
Inclusive of QL C Tasks Line Detection and Marking Surveys Correlation, Interpretation, and Presentation of Data; Resolution of Discrepancies
Quality Level A: I hereby certify that the following tasks have been completed:
Inclusive of QL B Tasks.
Selection of Test Locations.
Selection of Method.
Compliance with UNCL Requirements.
Excavation of Test Holes.
Collection, Recording, and Presentation of Data.
Site Restoration.
Interpretation of Data and Resolution of Discrepancies.
Signed:
Berwyn Wilbrink, A/E Manager, Jacobs
Enclosures: Utility Data Quality Certification Matrix cc: FHWA Right of Way Engineer (original for archives), FHWA Lead Designer
Lakewood Co, 80228
Definitions for Utility Data Quality Certification
QUALITY LEVEL D TASKS
Tasks leading to QL D include:
A. Records and Information Research.
Conduct appropriate investigations, e.g. owner records, DOT records, UNCL records, County records, personal interviews, visual inspections, etc., to help identify utility owners that may have facilities within the project limits or that may be affected by the project.
B. Records Collection.
Collect applicable records (e.g., utility owner base maps, "as built" or record drawings, permit records, field notes, geographic information system data, oral histories, etc.) on the existence and approximate location of existing involved utilities.
C. Records Review.
Review records for: evidence or indication of additional available records; duplicate or conflicting information; need for clarification.
D. Include Aerial or Ground-Mounted Facilities.
Include records research, identification, and depiction of aerial or ground mounted utility facilities in QL D tasks if specified (see "Miscellaneous Tasks").
E. Compilation and Presentation of Data.
1. Transfer information on all involved utilities to appropriate plan sheets, electronic files, and/or other documents as required or directed by DOT.
2. Exercise professional judgment to resolve conflicting information.
3. For information depicted, indicate: utility type and ownership; date of depiction; quality level(s); end points of any utility data; line status (e.g., active, abandoned, out of service); line size and condition; number of jointly buried cables; and encasement.
QUALITY LEVEL C TASKS
Tasks leading to QL C include:
A. Inclusive of QL D Tasks.
Perform tasks as described for QL D. There is no prescribed order in which QL D and C tasks must be performed.
B. Identification of Surface Utility Features.
Identify surface features, from project topographic data (if available) and from field observations, that are surface appurtenances of subsurface utilities.
C. Aerial or Ground-Mounted Facilities.
Include survey and correlation of aerial or ground-mounted utility facilities in QL C tasks if specified (see "Miscellaneous Tasks").
D. Surveys.
1. Survey surface features of subsurface utility facilities or systems, if such features have not already been surveyed by a registered professional. If previously surveyed, check survey data for accuracy and completeness.
2. The survey shall also include (in addition to subsurface utility features visible at the ground surface): determination of invert elevations of any manholes and vaults; sketches showing interior dimensions and line connections of such manholes and vaults; any surface markings denoting subsurface utilities, furnished by utility owners for design purposes.
Lakewood Co, 80228
3. Confined Space Procedures: Whenever the work requires the entry of personnel into confined spaces (including but not limited to manholes, vaults, and pipes), comply with applicable OSHA (Occupational Safety and Health Administration, U.S. Department of Labor) procedures and requirements.
E. Correlation, Interpretation, and Presentation of Data; Resolution of Discrepancies.
1. Exercise professional judgment to correlate data from different sources, and to resolve conflicting information.
2. Update (or prepare) plan sheets, electronic files, and/or other documents to reflect the integration of QL D and QL C information.
3. Recommend follow-up investigations (e.g., additional surveys, consultation with utility owners, etc.) as may be needed to further resolve discrepancies.
4. As appropriate, amend the indicated quality level of depicted information.
QUALITY LEVEL B TASKS
Tasks leading to QL B include:
A. Inclusive of QL C Tasks.
Perform tasks as described for QL C. There is no prescribed order in which QL C and B tasks must be performed.
B. Line Detection and Marking.
1. Select and apply appropriate surface geophysical method($ to search for and detect subsurface utilities within the project limits, and/or to trace a particular utility line or system.
2. Based on an interpretation of data, mark the indications of utilities on the ground surface, for subsequent survey. Utilize paint or other method acceptable to DOT for marking of lines.
3. Utilize the uniform color code of the American Public Works Association for marking of utilities.
4. Unless otherwise directed, mark centerline of single-conduit lines, and outside edges of multi-conduit systems.
5. Unless otherwise approved, maintain horizontal accuracy of +/- 1.5 feet (450 mm) in the marking of lines.
6. As an alternative to the physical marking of lines, the Consultant may, with DOT'S approval, utilize other means of data collection, storage, retrieval, and reduction that enables the correlation of surface geophysical data to the project's survey control.
C. Surveys.
1. Survey markings that indicate the presence of a subsurface utility.
2. Perform surveys to a horizontal accuracy consistent with applicable DOT survey standards.
Reference surveys to the project's survey control.
3. If requested, record depth information as may be indicated by the particular detection method used.
D. Correlation, Interpretation, and Presentation of Data; Resolution of discrepancies.
1. Exercise professional judgment to correlate data from different sources, and to resolve conflicting information.
2. Update (or prepare) plan sheets, electronic files, and/or other documents to reflect the integration of QL D, QL C, and QL B information.
3. Recommend follow-up investigations (e.g., additional surveys, consultation with utility
Lakewood Co, 80228
QUALITY LEVEL A TASKS
Tasks leading to QL A include:
A. Inclusive of QL B Tasks.
Perform tasks as described for QL B. There is no prescribed order in which QL B and A tasks must be performed.
B. Selection of Test Locations.
1. DOT may require QL A data where the precise horizontal and vertical location of utilities, obtained by exposure and survey of the utility at specific points, is needed for conflict assessment resolution purposes.
2. The Consultant may recommend test locations based on the requirements of the project and on existing subsurface utility information.
C. Selection of Method.
1. When available, verifiable information on previously exposed and surveyed utilities (such as survey records during utility line construction) shall be furnished in lieu of new excavation, exposure, and survey at that same point, or at a suitable nearby point.
2. Otherwise, when utility lines must be exposed and surveyed at specified locations, the Consultant shall use minimally intrusive excavation techniques, acceptable to DOT, that ensure the safety of the excavation, the integrity of the utility line to be measured, and that of other lines which may be encountered during excavation.
3. DOT intends that excavation shall be by means of air- or water-assisted vacuum excavation equipment manufactured specifically for the purpose. Provided, however, that approval of water-assisted vacuum excavation may be subject to additional findings by DOT that such method poses minimal risk of damage to the highway facility or utility lines.
D. Compliance with UNCL Requirements.
1. The Consultant shall comply with all applicable provisions of [State Law] when planning or performing excavations at utility test hole sites.
2. Compliance actions include, but are not limited to: notify owners or operators of underground utility facilities at least two (2) business days prior (not including the day of actual notice) to making or beginning excavations in the vicinity of such facilities; call the UNCL at for the marking of member utilities; contact non-member utilities directly; coordinate with utility owner representatives as required for inspection or other on-site assistance; immediately cease excavation work and report any resultant utility line damage to owner.
E. Excavation of Test Holes.
1. Clear the test borehole area of surface debris.
2. In paved areas, neatly cut and remove existing pavement, which cut shall not exceed 225 square inches (0.15 square meters) unless otherwise approved.
3. Excavate the test hole by the method(s) acceptable to DOT and to the standards set forth herein (see also "Selection of Method" above). The nominal diameter of the test hole shall not exceed 15 inches (375 mm) unless otherwise approved.
4. Expose the utility only to the extent required for identification and data collection purposes.
5. Avoid damage to lines, wrappings, coatings, cathodic protection or other protective coverings and features.
6. Hand-dig as needed to supplement mechanical excavation and to ensure safety.
7. Revise the test hole location as necessary to positively expose the utility.
8. Store excavated material for re-use or disposal, as appropriate.
F. Collection, Recording, and Presentation of Data.
Measure and/or record the following information on an appropriately formatted test borehole data sheet that has been sealed and dated by the Consultant:
Lakewood Co, 80228
1. Elevation of top and/or bottom of the utility tied to the project datum, to a vertical accuracy of +I- 0.05 feet (1 5 mm).
2. Elevation of existing grade over utility at test-hole.
3. Horizontal location referenced to project coordinate datum, to a horizontal accuracy consistent with applicable DOT survey standards.
4. Field sketch showing horizontal location referenced to a minimum of three (3) swing ties to physical structures existing in the field and shown on the project plans.
5. Approximate centerline bearing of utility line.
6. Outside diameter of pipe, width of duct banks, and configuration of non-encased multi-conduit systems.
7. Utility structure material composition, when reasonably ascertainable.
8. Identity of benchmarks used to determine elevations.
9. Utility facility condition.
10. Pavement thickness and type when applicable.
11. Soil type and site conditions.
12. Identity of utility owner/operator.
13. Other pertinent information as is reasonably ascertainable from test hole.
G. Site Restoration.
1. Replace bedding material around exposed utility lines in accordance with owner's specifications or as otherwise directed or approved.
2. Backfill and compact the excavation in a manner acceptable to DOT. If approved, re-use excavated material with appropriate moisture/density control.
3. Install color-coded warning ribbon within the backfill area and directly above the utility line.
4. As applicable, provide permanent ,pavement restoration within the limits of the original cut using materials, compaction, and pavement thickness acceptable to DOT.
5. Repair or replace backfill or pavement that fails (i.e., subsidence and/or loss of pavement material) within two (2) years of the original restoration work.
6. For excavations in unpaved areas, restore disturbed area as nearly as practicable to pre-existing conditions.
7. Furnish and install permanent surface marker (e.g., P.K. nail, peg, steel pin, or hub) directly above the centerline of the structure and record the elevation of the marker.
H. Interpretation of Data and Resolution of Discrepancies.
1. Exercise professional judgment to correlate data from different sources, and to resolve conflicting information.
2. Update plan & profile sheets, electronic files, and/or other documents to reflect the integration of QL D, QL C, QL B, and QL A information.
3. Recommend follow-up investigations (e.g., additional surveys, consultation with utility
UTILITY AGREEMENT APPENDIX
CORRESPONDENCE LOG
Walton, George
From: Walton, George Sent: Tuesday, July 28, 2020 5:26 PM To: Robert Quihuis; robertcampillo@centurylink.com Cc: Robbins, Dustin (FHWA); Wilbrink, Berwyn Subject: AZ FLAP 62(1), King Canyon Trailhead Attachments: AZ FLAP 62(1)_Utility_Summary_compiled.pdf
Gentlemen. We are constructing the subject project this fall. Our research indicates that your utility is present within the project limits. Please review the attached and provide any comments.
The work generally consists of excavating materials, constructing embankment and installing drainage structures. The existing gravel parking area will be upgraded to an asphalt concrete pavement.
Trico. We have performed initial coordination with Trico power. This coordination is reflected in the attached. We do not anticipate any conflicts with Trico distribution lines, but will be working in close proximity to the underground lines. Please review the attached and provide any feedback within two weeks.
Centurylink. We have made contact with local Centurylink personnel and anticipate this email will be forwarded to the appropriate contact person. Please review the attached, provide any schematics of the Centurylink lines in or adjacent to the project area and provide comments / information in the next two weeks.
Thank you both for your assistance to date. We plan to begin construction in mid‐October of this year. Your continued timely assistance is appreciated. Please contact me with any questions regarding the project and the attached.
George Walton, PE Jacobs
(303) 906‐1194 george.walton@jacobs.com
Sent: Thursday, July 16, 2020 10:48 AM To: Robert Quihuis Cc: Wilbrink, Berwyn Subject: RE: Trico Power Facilities at Kings Canyon Trailhead
Morning Robert. We have revised the design such that there should not be a conflict with the underground power.
I’m in the process of putting together the final paperwork for the project. Would you have time for a short call this afternoon or tomorrow? Thanks.
George Walton, PE Jacobs
From: Robert Quihuis <rquihuis@trico.coop> Sent: Friday, July 03, 2020 11:15 AM To: Wilbrink, Berwyn <Berwyn.Wilbrink@jacobs.com> Cc: Walton, George <George.Walton@jacobs.com>; Robbins, Dustin (FHWA) <dustin.robbins@dot.gov> Subject: [EXTERNAL] RE: Trico Power Facilities at Kings Canyon Trailhead
Berwyn, No problem. Thanks for the update.
Have a great 4th as well!
Thank you, Robert Quihuis Supervisor, Distribution Design
From: Wilbrink, Berwyn <Berwyn.Wilbrink@jacobs.com> Sent: Friday, July 3, 2020 10:13 AM To: Robert Quihuis <rquihuis@trico.coop> Cc: Walton, George <George.Walton@jacobs.com>; Robbins, Dustin (FHWA) <dustin.robbins@dot.gov> Subject: RE: Trico Power Facilities at Kings Canyon Trailhead
Robert:
This email originated from outside of Trico. Do not click links or open attachments unless you recognize the sender and know the content is safe.
We appreciate all you are doing. I’ll have the conduits added to the plans and send you a set soon so you can confirm they are correct.
We will require potholing confirmation before any excavation over the line.
Have a safe and relaxing fourth!!!!
Berwyn Wilbrink, PE
JACOBS
480.363.6328 Cell
Wishing you a safe and wonderful separation from us!
Sent: Friday, July 3, 2020 10:11 AM To: Wilbrink, Berwyn <Berwyn.Wilbrink@jacobs.com> Cc: Walton, George <George.Walton@jacobs.com>; Robbins, Dustin (FHWA) <dustin.robbins@dot.gov> Subject: [EXTERNAL] RE: Trico Power Facilities at Kings Canyon Trailhead
Hi Berwyn, I’ll try to answer your questions as best as I can.
We will attempt to show the features, buried 4‐ft to the top of the duct bank with 3 side by side 3” conduits (my guess of the worst case scenario). That would be the correct depth and conduit configuration.
Where the two duct banks converge (over the car in the aerial view in the parking lot), should we expect some kind of vault or pull box, or is that simply where the two duct banks cross? There is not a pull box here. The conduits would just cross each other. Seems a little weird we installed them like this and our GIS backgrounds are not 100% accurate, but it should be close to this alignment.
For 25kv, are they placed in a slurried or concrete trench, or just buried conduits? They are just buried conduits.
Finally, are there any formal drawings we can get a copy of that show the actual locations of the duct bank? I am looking for drawings in our archive database. Some of the older work orders like this one were done on the fly without formal drawings. I will send you whatever I can find.
I will send you anything drawing I find, but please let me know if you have any other questions. I look forward to receiving the detailed drawing showing our facilities.
Sent: Thursday, July 2, 2020 10:38 AM To: Robert Quihuis <rquihuis@trico.coop> Cc: Walton, George <George.Walton@jacobs.com>; Robbins, Dustin (FHWA) <dustin.robbins@dot.gov>
Good Morning Robert… we so appreciate the sharing of information.
We will attempt to show the features, buried 4‐ft to the top of the duct bank with 3 side by side 3” conduits (my guess of the worst case scenario).
Where the two duct banks converge (over the car in the aerial view in the parking lot), should we expect some kind of vault or pull box, or is that simply where the two duct banks cross?
For 25kv, are they placed in a slurried or concrete trench, or just buried conduits?
Finally, are there any formal drawings we can get a copy of that show the actual locations of the duct bank?
Once we get these shown into our plans, I’ll send you a set of cross sections and details to see if we have adequately addressed your facility.
Berwyn Wilbrink, PE
JACOBS
Sent: Wednesday, July 1, 2020 10:18 PM To: Wilbrink, Berwyn <Berwyn.Wilbrink@jacobs.com> Cc: Walton, George <George.Walton@jacobs.com> Subject: [EXTERNAL] RE: Trico Power Facilities at Kings Canyon Trailhead
Hi Berwyn, I apologize for not responding sooner. My email inbox has been buried over the past several months now that we are doing everything remotely.
I will make sure I get all your questions answered moving forward.
Below is a quick screenshot of our system map overlaid on your concept plan (as best as I could). The solid orange lines are our 25kV Overhead lines and the dashed orange lines represent our underground 25kV lines.
The standard depth of our underground lines is 48” to the top of the conduits. There would be (3)3” conduits w/ energized cable in each of the dashed lines.
This email originated from outside of Trico. Do not click links or open attachments unless you recognize
Please review the information above and let me know if you see any conflicts with our existing facilities. This line is pretty old, so there might not be AutoCAD or accurate GIS information on it.
I will check tomorrow.
Trico Electric Cooperative, Inc.
PO Box 930 • Marana, AZ 85653 Phone: (520) 744‐2944, ext. 1372 • Cell: (520) 591‐9429 Trico is an equal opportunity provider and employer
Sent: Friday, June 5, 2020 2:45 PM To: Robert Quihuis <rquihuis@trico.coop>
Cc: Walton, George <George.Walton@jacobs.com>
Sorry…. Hit send too soon
Berwyn Wilbrink, PE
JACOBS
From: Wilbrink, Berwyn Sent: Friday, June 5, 2020 2:41 PM To: rquihuis@trico.coop Cc: Walton, George <George.Walton@jacobs.com> Subject: Trico Power Facilities at Kings Canyon Trailhead
HI Robert:
On behalf of Federal Highways, we are improving the parking lot shown in the attached exhibit.
Trico has overhead lines to the north of our improvement site that appear to drop and go underground.
We wish to confirm that there are no conflicts with your existing infrastructure, so if you can send us any maps or as‐ builts of your facilities in this area, it would be greatly appreciated.
Berwyn Wilbrink, PE Transportation Group Manager
JACOBS
480.363.6328 Cell
Berwyn.Wilbrink@jacobs.com www.Jacobs.com
NOTICE - This communication may contain confidential and privileged information that is for the sole use of the intended recipient. Any viewing, copying or distribution of, or reliance on this message by unintended recipients is strictly prohibited. If you have received this message in error, please notify us immediately by replying to the message and deleting it from your computer.
NOTICE - This communication may contain confidential and privileged information that is for the sole use of the intended recipient. Any viewing, copying or distribution of, or reliance on this message by unintended recipients is strictly prohibited. If you have received this message in error, please notify us immediately by replying to the message and deleting it from your computer.
NOTICE - This communication may contain confidential and privileged information that is for the sole use of the intended recipient. Any viewing, copying or distribution of, or reliance on this message by unintended recipients is strictly prohibited. If you have received this message in error, please notify us immediately by replying to the message and deleting it from your computer.
This email originated from outside of Trico. Do not click links or open attachments unless you recognize
From: Miller, Tony <Tony.Miller@CenturyLink.com> Sent: Friday, July 31, 2020 1:20 PM To: Walton, George Cc: Wilbrink, Berwyn Subject: [EXTERNAL] AZ FLAP 62(1), King Canyon Trailhead CenturyLink conflict review status of utility Attachments: CENTURYLINK CONFLICT REVIEW RESPONSE.pdf
Good afternoon Please see attached CenturyLink pdf conflict review response.
Thx Tony This communication is the property of CenturyLink and may contain confidential or privileged information. Unauthorized use of this communication is strictly prohibited and may be unlawful. If you have received this communication in error, please immediately notify the sender by reply e‐mail and destroy all copies of the communication and any attachments.
From: Campillo, Robert <Robert.Campillo@CenturyLink.com> Sent: Wednesday, July 29, 2020 6:39 AM To: Jones, Robert; Sotero, Andrew Cc: Walton, George Subject: [EXTERNAL] FW: AZ FLAP 62(1), King Canyon Trailhead Attachments: AZ FLAP 62(1)_Utility_Summary_compiled.pdf
Bob and Andrew, George from Jacobs engineering company contacted me and ask to forward to our engineer and OPS team.
They will be doing work in Southwest.
Thanks, Rob
From: Walton, George <George.Walton@jacobs.com> Sent: Tuesday, July 28, 2020 5:15 PM To: Campillo, Robert <Robert.Campillo@CenturyLink.com> Subject: FW: AZ FLAP 62(1), King Canyon Trailhead
Forgot the period between first and last. Please see below. Many thanks.
George Walton, PE Jacobs
Sent: Tuesday, July 28, 2020 5:26 PM To: Robert Quihuis <rquihuis@trico.coop>; robertcampillo@centurylink.com Cc: Robbins, Dustin (FHWA) <dustin.robbins@dot.gov>; Wilbrink, Berwyn <Berwyn.Wilbrink@jacobs.com> Subject: AZ FLAP 62(1), King Canyon Trailhead
Gentlemen. We are constructing the subject project this fall. Our research indicates that your utility is present within the project limits. Please review the attached and provide any comments.
The work generally consists of excavating materials, constructing embankment and installing drainage structures. The existing gravel parking area will be upgraded to an asphalt concrete pavement.
Trico. We have performed initial coordination with Trico power. This coordination is reflected in the attached. We do not anticipate any conflicts with Trico distribution lines, but will be working in close proximity to the underground lines. Please review the attached and provide any feedback within two weeks.
Centurylink. We have made contact with local Centurylink personnel and anticipate this email will be forwarded to the appropriate contact person. Please review the attached, provide any schematics of the Centurylink lines in or adjacent to the project area and provide comments / information in the next two weeks.
Thank you both for your assistance to date. We plan to begin construction in mid‐October of this year. Your continued timely assistance is appreciated. Please contact me with any questions regarding the project and the attached.
George Walton, PE Jacobs
NOTICE - This communication may contain confidential and privileged information that is for the sole use of the intended recipient. Any viewing, copying or distribution of, or reliance on this message by unintended recipients is strictly prohibited. If you have received this message in error, please notify us immediately by replying to the message and deleting it from your computer.
This communication is the property of CenturyLink and may contain confidential or privileged information. Unauthorized use of this communication is strictly prohibited and may be unlawful. If you have received this communication in error, please immediately notify the sender by reply e‐mail and destroy all copies of the communication and any attachments.
| 000_King Canyon Progress Print_20200727_UTILITY.pdf |
| A02-STFLAP69_01 |
| A03-STFLAP69_02 |
| D03-PNPFLAP69_03 |
| D04-PNPFLAP69_04 |
| D07-PNPFLAP69_07 |
| E02-C157-50 |
| E03-C157-51_1 |
| E04-C157-51_2 |
| E05-C157-53 |
| E06-C157-55 |
| F01-211-A_SP |
| G01-251-A_SP |
| G02-ST251_50 |
| G03-ST251_51 |
| R01_ST501-1 |
| R02_ST501-2 |
| T01-ST602-A |
| T02-ST602-B |
| T03-ST602-C |
| T04-ST602-D |
| T05-ST602-E |
| T06-SP604-A |
| V02-SSTFLAP69_02 |
| V03-SSTFLAP69_03 |
| V04-SSTFLAP69_04 |
| W03-ST635-06 |
| W04-ST635-10 |
| W05-ST635-14 |
| king canyon_updated sheets_072720.pdf |
| A01-TTLFLAP69_01 |
| A05-TYPFLAP69_01 |
| B1 |
| B2 |
| B3 |
| B4 |
| B5 |
| B6 |
| B7 |
| B8 |
| D01-PNPFLAP69_01 |
| D02-PNPFLAP69_02 |
| D05-PNPFLAP69_05 |
| D06-PNPFLAP69_06 |
| E01-ECPFLAP69 |
| T07-SP609-A |
| V01-SSTFLAP69_01 |
| W01-TTC |
| W02-SP635-A |
| Coorespondence_200806.pdf |
| Memo Style_Trico_02 |
| Memo Style_Trico_01 |
| Memo Style_CL_02 |
| CENTURYLINK CONFLICT REVIEW RESPONSE |
| Memo Style_CL_01 |