HVAC LEGEND
SYMBOL DESCRIPTION ABBR. DESCRIPTION
LOW PRESSURE CONDENSATE RETURN PIPING
HOT WATER SUPPLY PIPING
HOT WATER RETURN PIPING
HIGH TEMPERATURE HOT WATER SUPPLY PIPING
HIGH TEMPERATURE HOT WATER RETURN PIPING
CHILLED WATER SUPPLY PIPING
CHILLED WATER RETURN PIPING
SUPPLY DUCT UP / SUPPLY DUCT DOWN
RETURN DUCT UP / RETURN DUCT DOWN
FLEXIBLE DUCT CONNECTION
BACKDRAFT DAMPER
TEMP. CONTROL DAMPER-OPPOSED BLADE
LOUVER WITH SCREEN
MANUAL VOLUME DAMPER
MOTOR OPERATED DAMPER
SPIN-IN FITTING WITH MVD
CONDENSER WATER SUPPLY PIPING
LOW PRESSURE STEAM SUPPLY PIPING (0 - 15#)
ROUND DUCT UP / ROUND DUCT DOWN
INDICATES FLAT OVAL DUCTWORK
ABBR. SYMBOL
COOLING COIL DRAIN PAN PIPING
TEMP. CONTROL DAMPER- PARELLEL BLADE
LPS
LPC
MPS
MVD
MPC
BBD
BF
RL
RS
RHG
TT
MEDIUM PRESSURE STEAM SUPPLY PIPING (16# - 60#)
MEDIUM PRESSURE CONDENSATE RETURN PIPING
HIGH PRESSURE STEAM SUPPLY PIPING (61# - 125#)
HIGH PRESSURE CONDENSATE RETURN PIPING
PUMPED CONDENSATE PIPING
BOILER BLOWDOWN PIPING
REFRIGERANT SUCTION PIPING
BOILER FEED WATER PIPING
FLOAT AND THERMOSTATIC STEAM TRAP
REFRIGERANT LIQUID PIPING
REFRIGERANT HOT GAS PIPING
TCD
FD
FSD
SD
DAD
TEMPERATURE SENSOR
DUCT FIRE DAMPER
COMBINATION DUCT SMOKE & FIRE DAMPER
DUCT SMOKE DAMPER
DUCT SMOKE DETECTOR
DUCT ACCESS DOOR
ELECTRIC-PNEUMATIC CONTROL VALVE
TURNING VANES IN DUCT ELBOW
WALL MOUNTED THERMOSTAT
PNEUMATIC-ELECTRIC CONTROL SWITCH
LOUVER
HUMIDISTAT
DUCT RISE
UNIT MOUNTED THERMOSTAT
UNDERCUT DOOR
THERMOSTATIC STEAM TRAP
DUCT DROP
HWS
HWR
HTWS
HTWR
CWS
CWR
D
C
CR
HPS
HPC
PC
F&T
IBT
TCV
MAV
AAV
FS
EJ
BJ
RSV
DPS
(2 OR 3-WAY) TEMPERATURE CONTROL VALVE
INVERTED BUCKET STEAM TRAP
VENTURI METER
CALIBRATED BALANCING VALVE
REFRIGERANT SERVICE VALVE
AUTOMATIC AIR VENT
DIFFERENTIAL PRESSURE SWITCH
MANUAL AIR VENT
FLOW SWITCH
EXPANSION JOINT
CONDENSER WATER RETURN PIPING
BALL JOINT EXPANSION COMPENSATOR
LPS
LPC
MPS
MPC
BBD
BF
RL
RS
RHG
HWS
HWR
HTWS
HTWR
CWS
CWR
D
C
CR
HPS
HPC
PC
SUPPLY & RETURN BRANCH
PIPING TO TERMINAL UNIT
C W
R ,H
W R
C W
S ,H
W S
CWS,CWR/HWS,HWR
ACOUSTICALLY LINED DUCTWORK
TEMPERATURE CONTROL OUTSIDE AIR DAMPER
TEMPERATURE CONTROL RETURN AIR DAMPER
TEMPERATURE CONTROL EXHAUST AIR DAMPER
STATIC PRESSURE IN INCHES WATER COLUMN
SUPPLY AIR DEVICE
RETURN AIR DEVICE
M
TS
F
T
T
H
U
L
R
D
SD
RG
SP IN WC
TCEAD
TCRAD
TCOAD
A.L.
48F12
TCD
BDD
EP
PE
DOUBLE/SINGLE LINE DUCT LEGEND
45° TEE (ROUND) FLEX DUCT 90° RADIUS ELBOW
RIGID FLEX
45° TEE (RECTANGULAR) 90° TEE (ROUND) MANUAL VOLUME DAMPER 90° ELBOW
DUCT SPLIT REDUCER 45° ELBOWGRD RUNOUT
90° TEE (RECTANGULAR)
SEE DUCT
TAKE-OFF DETAIL
CONICAL
TEE
VOLUME
DAMPER
PLUMBING LEGEND
SYMBOL DESCRIPTION ABBR. DESCRIPTION
ACID RESISTANT WASTE PIPING (ABOVE FLOOR IN BUILDING)
DOMESTIC COLD WATER PIPING
DOMESTIC HOT WATER PIPING
DOMESTIC HOT WATER CIRC. PIPING
SOFTENED DOMESTIC COLD WATER PIPING
SOFTENED DOMESSTIC HOT WATER PIPING
DOMESTIC HOT WATER PIPING @ TEMPERATURE SHOWN
SURFACE CLEANOUT
FLOOR CLEANOUT
LINE CLEANOUT
FIXTURE OR DRAIN P-TRAP
AREA DRAIN
FLOOR SINK (SQUARE GRATE)
ROOF DRAIN OR OVERFLOW DRAIN
GAS PRESSURE REDUCING VALVE
ATMOSPHERIC VACUUM BREAKER
ACID RESISTANT VENT PIPING
WASTE PIPING (ABOVE FLOOR IN BUILDING)
WASTE PIPING (BELOW FLOOR IN BUILDING)
WALL CLEANOUT
CLEANOUT TEE
ABBR. SYMBOL
VENT PIPING
FLOOR DRAIN (ROUND GRATE)
HW
HWC
C-SW
140° HW
V
H-SW
AV
W
W
AW
AW
CW
FS
RD / OD
VB
AV
W
W
AW
AW
GD
IW
S
ST
SSD
SD
SD
OD
OD
A
G G
ACID RESISTANT WASTE PIPING (BELOW FLOOR IN BUILDING)
IW
S
ST
SSD
SD
GD
SD
OD
OD
A COMPRESSED AIR
GREASE DRAIN (WASTE LINE TO GREASE INTERCEPTOR)
INDIRECT WASTE PIPING
SANITARY SEWER PIPING (OUTSIDE BUILDING)
STORM SEWER PIPING (BELOW GRADE OUTSIDE BUILDING)
SUB-SURFACE DRAIN PIPING
OVERFLOW DRAIN PIPING (ABOVE FLOOR IN BUILDING)
STORM DRAIN PIPING (ABOVE FLOOR IN BUILDING)
STORM DRAIN PIPING (BELOW FLOOR IN BUILDING)
OVERFLOW DRAIN PIPING (BELOW FLOOR IN BUILDING)
FCO
WCO
COT
AD
LCO
FD
SCO
BFP
SA
GC
FC
WH
HB
YH
MH
CI
MANHOLE
DOUBLE CHECK BACKFLOW PREVENTER
SHOCK ARRESTOR W / ISOLATION VALVE
GAS SHUT-OFF VALVE
STOP AND DRAIN VALVE
HOSE BIBB
HWC BALANCING VALVE
CAST IRON
WALL HYDRANT
YARD HYDRANT
INVERT ELEVATION
CATCH BASIN
POLYVINYL CHLORIDE
VITRIFIED CLAY PIPE
VENT THRU ROOF
VCP
CB
VTR
IE
PVC
SW
SW
140°
GENERAL LEGEND
SYMBOL DESCRIPTION ABBR. DESCRIPTION
NEW
SECTION DESIGNATION
SECTION DRAWN ON THIS SHEET
SECTION CUT ON THIS SHEET
RISER DIAGRAM NUMBER
SHEET RISER IS DRAWN ON
EQUIPMENT UNIT IDENTIFICATION
CAP END OF PIPE
PITCH DOWN IN DIRECTION OF ARROW
UNION OR FLANGE
CONCENTRIC PIPE REDUCER
ECCENTRIC PIPE REDUCER
PRESSURE AND/OR TEMPERATURE RELIEF VALVE
PLUG VALVE
GATE VALVE
VERTICAL PIPE VALVE
DIFFUSER IDENTIFICATION
DIFFUSER NECK DIAMETER
DIFFUSER CFM
EXISTING
PIPE ANCHOR
PIPE ALIGNMENT GUIDE
ABBR. SYMBOL
EQUIPMENT UNIT NUMBER
PRESSURE REDUCING VALVE
(E)
(N)
(R)
PTRV
(F)
DIA
WAD
NIC
AFF
GC
MC
EC
RELOCATED
FUTURE
POINT OF CONNECTION, NEW TO EXISTING
DIRECTION OF FLOW IN PIPE
DUCTWORK, PIPING AND EQUIPMENT TO BE REMOVED
DIAMETER
ABOVE FINISHED FLOOR
WALL ACCESS DOOR
ELECTRICAL CONTRACTOR
NOT IN CONTRACT
GENERAL CONTRACTOR
PRV
GLV
BFV
BV
CV
P/T
STRAINER W/ BLOWDOWN
GLOBE VALVE
BUTTERFLY VALVE
BALL VALVE
CHECK VALVE
SOLENOID VALVE
PRESSURE / TEMPERATURE TAP
BUTTERFLY SOLENOID VALVE
FLEXIBLE PIPE CONNECTOR
HOSE END DRAIN VALVE
STRAINER
CEILING ACCESS PANEL
PRESSURE GAUGE
PUMP
THERMOMETER
SIGHT GLASS
C.A.P.
TB
MECHANICAL CONTRACTOR
UNIT
M-X
X
X.X X.X
X
GV
THRUST BLOCK
XX
P/T
DETAIL SHEETS PLAN SHEETS
XX
NATURAL GAS PIPING
(Not all symbols listed below are used on these drawings) (Not all symbols listed below are used on these drawings)
(Not all symbols listed below are used on these drawings)
NECK
CFM
X
EXHAUST DUCT UP / EXHAUST DUCT DOWN
WALL MOUNTED CARBON DIOXIDE SENSORC
EXHAUST AIR DEVICEEG
KEYNOTE
SINGLE LINEDOUBLE LINEDOUBLE LINESINGLE LINE SINGLE LINE
FLEXRIGID
SINGLE LINE DOUBLE LINE DOUBLE LINE
(Not all symbols listed below are used on these drawings)
DP
T
IBT
F&T
TT
R N
D
R E
C
45° TAKEOFF
SPIN IN
X
RETURN AIR DEVICE WITH SOUND BOOTRG
ISSUE / REVISION:
PROJECT NUMBER
DATE
DRAWN BY
CHECKED BY
NO. DESCRIPTION DATE
475 17th Street, Suite 720 Denver, Colorado 80202 Phone: 720-855-7572 www.iron-horse-architects.com
This document is an instrument of services and as such, remains the property of the Architect.
The use of this document is limited and can be extended only by written agreement with IRON
HORSE ARCHITECTS, INC.
COPYRIGHT 2015 ©
D R e v it L o c a l F ile s \2
\M
E P
-N
IS
T W in g
C u s to m iz a ti o n A
A c re e .r v t
/3
/2
:3 :5
P
M
MECHANICAL
LEGENDS & NOTES
W
IN
G
R E
-C U
S T
O M
IZ
A
T
IO
N
M0.1.0
201009.006
AJA
3/30/16
B ro a d w a y
B o u ld e r, C O
GENERAL NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
WORK INCLUDED IN THE CONTRACT IS DENOTED IN BOLD. EXISTING CONDITIONS
TO REMAIN ARE DENOTED LIGHTLY.
A DETAILED METHOD OF PROCEDURE IS REQUIRED WHEN A CONSTRUCTION
ACTIVITY AFFECTS THE SAFETY OF THE OCCUPANTS, OWNER'S EQUIPMENT OR
VALUABLE CONTENTS OR ANY SYSTEM WHICH SUPPORTS THESE SYSTEMS; OR
ESSENTIALLY AFFECTS THE BUILDING MANAGEMENT, OPERATIONS OR SECURITY.
CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING
CONDITIONS PRIOR TO COMMENCEMENT OF ANY WORK AND SHALL NOTIFY THE
ENGINEER/ARCHITECT OF ANY DISCREPANCIES FOR RESOLUTION.
COORDINATE WORK WITH ALL TRADES.
CONTRACTOR IS RESPONSIBLE FOR SECURING AND WEATHERPROOFING ANY
ROOF OPENING NOT COMPLETED DURING WORKING HOURS.
COORDINATE ALL DUCTWORK AND PIPING WITH EQUIPMENT, STRUCTURE, ETC.
CONTRACTOR SHALL BE RESPONSIBLE FOR DEACTIVATION OF ROOF-MOUNTED
EQUIPMENT AND ASSOCIATED INDOOR EQUIPMENT. ONLY ONE UNIT SHALL BE
TAKEN OUT OF SERVICE AT ANY TIME, WITH REMAINDER OF UNITS LEFT
OPERATIONAL.
CONTRACTOR SHALL NOT SHUT DOWN / TAKE OUT OF SERVICE ANY SYSTEMS
WITHOUT FIRST COORDINATING WITH OWNER AND PREPARING M.O.P.
HVAC PLAN NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
ALL SUPPLY AIR DIFFUSERS ARE 4-WAY AIR PATTERN UNLESS SHOWN
OTHERWISE.
DUCT SIZE OF BRANCH DUCT TO AIR DEVICE SHALL BE THE SAME SIZE AS NECK
SIZE OF AIR DEVICE UNLESS NOTED OTHERWISE.
ALL HEATING WATER SUPPLY AND RETURN BRANCH PIPING TO TERMINAL BOXES
SHALL BE 3/4" UNLESS NOTED OTHERWISE. ALL PIPING TAKE-OFFS FROM MAINS
SHALL BE BOTTOM/TOP TAKE-OFFS WITH SWING JOINTS.
BRANCH DUCT SIZE TO INLET OF ALL TERMINAL BOXES SHALL BE THE SAME SIZE
AS THE INLET SCHEDULED UNLESS NOTED OTHERWISE. BRANCH DUCTS TO
TERMINAL BOXES EXCEEDING 15' OR TWO ELBOWS, SHALL BE UP-SIZED TO NEXT
STANDARD DIAMETER.
UNLESS OTHERWISE NOTED, ALL SUPPLY AIR DUCTWORK SHALL BE
EXTERNALLY WRAPPED TO THICKNESS AS STATED IN SPECIFICATIONS. RETURN
AND EXHAUST DUCTWORK IS NEITHER LINED NOR WRAPPED.
PROVIDE ROOM AIR BALANCE TO ACHIEVE POSITIVE (+) OR NEGATIVE (-) AT THE
DIFFERENTIAL PRESSURE INDICATED ON THE DRAWINGS.
PROVIDE EOMD AT ALL LOW POINTS FOR STEAM SUPPLY PIPING AS REQUIRED
WHICH MAY NOT NECESSARILY BE SHOWN.
ALL BRANCH STEAM SUPPLY AND CONDENSATE RETURN PIPING FROM MAINS
SHALL BE TOP TAKE-OFFS WITH SWING JOINTS.
PLUMBING NOTES:
1.
2.
3.
4.
CONTRACTOR SHALL NOT SHUT-OFF/PUT OUT OF SERVICE ANY
SYSTEMS/SERVICES WITHOUT FIRST COORDINATING WITH OWNER.
CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING
CONDITIONS PRIOR TO COMMENCEMENT OF ANY WORK AND SHALL NOTIFY THE
ARCHITECT/ENGINEER OF ANY DISCREPANCIES FOR RESOLUTIONS.
THIS CONTRACTOR SHALL COORDINATE LOCATIONS OF PIPING WITH OTHER
TRADES AND ADVISE ARCHITECT/ENGINEER OF ANY POSSIBLE CONFLICTS.
VERIFY EXACT LOCATIONS, ELEVATIONS AND DIMENSIONS OF STRUCTURAL
MEMBERS AND OPENINGS.
ALL LAB GAS PIPING SHALL HAVE TOP TAKE-OFFS WHENEVER POSSIBLE.
ISSUE FOR CONSTRUCTION 03/30/161
540-1 845-01 510-04
PRESSURE INDEPENDENT CONTROL VALVES
FOR SMALL CHILLED WATER VALVES (TYP.)
REFER TO WATER COOLED EQUIPMENT
PIPING DETAIL.
PCWR (LAB)
CWR PCWS
PCWS (LAB)
CWS
DP
ET
PCWP
PFHX
PCWP
VFD
VFD
COUPON RACK
POT FEEDER
EXP.
TANK
SEPARATOR
AIR
M
TO DRAIN
RPBFP
TURBINE
FLOW
METER
P.I. CONTROL VALVE
(BACKUP DOMESTIC WATER COOLING)
1-1/2"CW
2"
PROCESS CHILLED WATER
TO LAB EQUIPMENT (TYP.)
MINIMUM FLOW VALVE
(20 GPM). RE: FLOOR
PLANS FOR LOCATION.
2" 4"
3/4"CW
1-1/2"
ATTACH PUMP TO CONCRETE
HOUSEKEEPING PAD PER MFR.
INSTRUCTIONS.
1/2"
HOSE END
DRAIN
VALVE
AIR
CHARGING
PORT
(MECH SYSTEM MAKEUP)
WATER METER
1-1/2"CW
PROCESS COOLING 1-LINE DIAGRAM
IN-LINE PUMP PIPING DETAIL EXCHANGER PIPING DETAIL
PLATE AND FRAME HEAT
EXPANSION TANK DETAIL
SCALE: NONE
SCALE: NONE
PUMP
PORTS ON PUMP
FLANGE
P/T
PRESSURE GAUGE
PROVIDE FLOW
DEVICE AND BALANCING
COCK PER SPEC
CHECK VALVE
P/T
1/2" TUBING OR
IPS. SAME MATERIAL
AS TRANSPORT PIPING
SCALE: NONE
P C
H W
S
LTCHWSPCHWS
UNION
PCHWR
THERMOMETER
LTCHWR
PRESSURE GAUGE
L T
C H
W S
PRESSURE
INDEPENDENT
CONTROL VALVE.
SAME-SIDE, COUNTER-FLOW
MANUAL AIR
VENT (TYP)
3/4" DRAIN VALVE
W/HOSE END CONN.
COORDINATE PIPE CONNECTION ARRANGMENT WITH MANUFACTURER'S REQUIREMENTS.
HOUSEKEEPING
PAD
P/T P/T
P/T P/T
SCALE: NONE
FLOOR
AIR SEPARATOR
PUMP
N.O.
HIGH
CAPACITY
AUTO AIR
VENT
BACKFLOW PREVENTER @ 5' A.F.F.
MAX. WITH DRAIN FUNNEL AND DRAIN
PIPED TO DRAIN. SEE PLUMBING PLANS
DOMESTIC
MAKE-UP
WATER
TO
SYSTEM
3/4" FEMALE
HOSE
CONNECTION
FOR QUICK FILL
OUTLET SIZE
BLOW DOWN
VALVE W/HOSE END
EXPANSION
TANK SEE PUMP DETAIL
FOR ADDITIONAL
DATA
FROM
SYSTEM
FULL-SIZE DISCHARGE
PIPE FROM AIR VENT TO
FLOOR DRAIN W/AIR GAP
PRESSURE
REDUCING VALVE
ASSEMBLY
PLATE AND FRAME HEAT EXCHANGER SCHEDULE
HEAT PLATES HIGHER TEMPERAURE SIDE LOWER TEMPERATURE SIDE SIZE (INCHES)
DESIG. MFR. MODEL SERVICE TRANSFER MBH NUMBER EXTENSION EWT LWT GPM PROP WATER EWT LWT GPM PROP WATER L W H OPER REMARKS
AREA TRANSFER FOR CAPACITY °F °F GLYCOL P.D. °F °F GLYCOL P.D. WEIGHT
(SF) DESIGN % (FT WC) % (FT WC) (LBS)
PFHX-1 ALFA LAVAL AQ2L
PROCESS
CHILLED WATER
376 1,300 139 43 68 48 130 0% 11.0 44 64 130 0% 11.0 40 13 51 900
REMARKS:
1. PROVIDE INSULATED COVERING OVER PLATES WITH ALUMINUM COVER.
3/29/2016 17:37 P:\2016\2016-068 NIST Wing 3 Customization\Cad\Mech\Mschedules\[M-2016-068.xlsx]S970-4 Tmp Mtrx
PUMP SCHEDULE
MAX MOTOR VIBRATION INLET OUTLET OPER.
DESIG. MFR. MODEL PUMP TYPE SERVICE PUMP PROP GPM PRESSURE NPSH EFF. MIN. RPM VFD/ VFD ISOLATOR SIZE SIZE WEIGHT REMARKS
OPER GLYCOL (FT HD) (FT HD) % HP AT RELAY/ BYPASS TYPE (IN.) (IN.) LBS.
°F (%) 60HZ STARTER (YES/
NO)
PCWP-1 GRUNDFOS CR20-5
VERTICAL
MULTISTAGE
PROCESS
CHILLED WATER
125 0% 130 220 14.5 68 15.0 3500 VFD NO -- 2 2 305
PCWP-2 GRUNDFOS CR20-5
VERTICAL
MULTISTAGE
PROCESS
CHILLED WATER
125 0% 130 220 14.5 68 15.0 3500 VFD NO -- 2 2 305
APPLIES TO ALL:
> REFER TO ELECTRICAL DRAWINGS FOR POWER REQUIREMENTS.
REMARKS:
1. PUMPS OPERATING THRU VFDS: UPON SELECTING THE PUMP FOR THE SPECIFIED DUTY POINT, THE SUPPLIER SHALL PROVIDE THE PUMP WITH THE LARGEST IMPELLER SIZE AVAILABLE FOR THE CASING THAT DOES NOT EXCEED THE DUTY POINT MOTOR HP AT THE RIGHT END OF THE CURVE. SUBMITTAL DATA SHALL SHOW ALL IMPELLER CURVES AVAILABLE FOR THE PUMP MODEL. THIS APPLIES TO ALL MANUFACTURERS.
2. UNLESS INDICATED BY PUMP MODEL NUMBER, VARIABLE FREQUENCY DRIVE (VFD) IS REMOTE-MOUNTED RATHER THAN PUMP MOUNTED WHEN REQUIRED.
3. PROVIDE SHAFT GROUNDING RINGS FOR EACH BEARING ON MOTORS POWERED THROUGH VARIABLE FREQUENCY DRIVES.
3/29/2016 17:37 P:\2016\2016-068 NIST Wing 3 Customization\Cad\Mech\Mschedules\[M-2016-068.xlsx]S970-4 Tmp Mtrx
EXPANSION TANK SCHEDULE
CAPACITY PRE-CHARGE OPER.
DESIGNATION MANUFACTURER MODEL ACCEPT. TANK SERVICE PRESSURE WEIGHT REMARKS
VOL. VOL. (PSIG) (LBS)
ET-1 B&G D-80 22.6 44.4
PROCESS CHILLED
WATER
30 516 NOTE 1
NOTES:
1. PROVIDE ASME RATED TANK.
3/29/2016 17:37 P:\2016\2016-068 NIST Wing 3 Customization\Cad\Mech\Mschedules\[M-2016-068.xlsx]S970-4 Tmp Mtrx
TEMPERATURE CONTROL MATRIX
POINT TYPE ANALOG IND. ALARM
POINTS LIST: N
O
O
F U
N
IT
S
D
IG
IT
A
L I N
P U
T
D
IG
IT
A
L O
U T
P U
T
A N
A L
O G
I N
P U
T
A N
A L
O G
O U
T P
U T
T E
M P
E R
A T
U R
E
R E
L H
U M
ID
IT
Y
P O
S
IT
IO
N
/S P
E E
D /L
E V
E L
P R
E S
S U
R E
S T
A T
U S
H
IG
H
L O
W
M A
IN
T
E N
A N
C E
P K
G D
E
Q U
IP
A
L A
R M
E M
S P
R O
G R
A M
S
REMARKS
PROCESS CHILLED WATER SYSTEM
Process Cooling Pump Start/Stop 2 X
Process Cooling Pump Status 2 X X
Process Cooling Pump VFD Speed 2 X X
Process Cooling Pump VFD Fault 2 X X
HX Control Valve 1 X X
Process Cooling Supply Temp 1 X X
Process Cooling Return Temp 1 X X
Process Cooling System dP 1 X X
Process Cooling Makeup Water Meter Flow 1 X
Process Cooling Min Flow Valve 1 X X
Process Cooling Flow Meter 1 X X
LTCHWS Isolation Valve 1 X X
LTCHWR Isolation Valve 1 X X
Backup Cooling Supply Isolation Valve 1 X X
Backup Cooling Supply Control Valve 1 X X
NOTES:
(Notes that are not explicitly referenced in the above schedule are to be considered general notes that apply to all items in the schedule.)
1. The Temperature Control Matrix, Control Diagrams, and the Sequence of Operation are all binding. If there is a discrepancy between them, the worst case scenario shall be used for bidding purposes. Additional costs will not be allowed for discrepancies between the specifications and the drawings.
2. See plans for quantity.
AIR SEPARATOR SCHEDULE
PRESSURES SIZE (INCHES)
DESIG. SERVICE MANUFACTURER MODEL NO. STYLE GPM PROP WPD STRAINER INLET/ RATED OPER LxW HEIGHT OPER REMARKS
GLYCOL (FT HD) (YES/NO) OUTLET (PSIG) (PSIG) WEIGHT
% SIZE (LBS)
(IN)
AS-1
PROCESS CHILLED
WATER
SPIROTHERM VSR400
STANDARD AIR
MICRO-BUBBLE
130 0% 1.0 N/A 4 150 32 21x9 24 145 1,2,3
REMARKS:
1. PROVIDE AUTOMATIC AIR VENT INTEGRAL OR SEPARATELY.
2. ASME CONSTRUCTION.
3. STANDARD VELOCITY MODEL.
3/8/2016 P:\2016\2016-068 NIST Wing 3 Customization\Cad\Mech\Mschedules\[M-2016-068.xlsx]S120-2 AirSep
ISSUE / REVISION:
PROJECT NUMBER
DATE
DRAWN BY
CHECKED BY
NO. DESCRIPTION DATE
475 17th Street, Suite 720 Denver, Colorado 80202 Phone: 720-855-7572 www.iron-horse-architects.com
This document is an instrument of services and as such, remains the property of the Architect.
The use of this document is limited and can be extended only by written agreement with IRON
HORSE ARCHITECTS, INC.
COPYRIGHT 2015 ©
D R e v it L o c a l F ile s \2
\M
E P
-N
IS
T W in g
C u s to m iz a ti o n A
A c re e .r v t
/3
/2
:3 :5
P
M
MECHANICAL
SCHEDULES AND
DETAILS
W
IN
G
R E
-C U
S T
O M
IZ
A
T
IO
N
M0.2.0
201009.006
AJA
3/30/16
B ro a d w a y
B o u ld e r, C O
MAINT.
ACCESS
MAINT.
ACCESS
4"ø MTCHWR
3"ø HHWS
1 1/4"ø LTCHWR
/4
"ø C
D
"ø
L T
C H
W S
"ø
L T
C H
W R
1 1/4"ø LTCHWS
3"ø HHWR 2 1/2"ø HHWR 2 1/2"ø HHWS
3"ø MTCHWR
1"ø HHWR 1"ø HHWS
3"ø HHWR
4"ø MTCHWS
2 1/2"ø MTCHWR
2 1/2"ø MTCHWS
3"ø MTCHWS
2"ø HHWR
2"ø HHWS
RGRFRERDRCRBRANLKH
37.137
32.1
MEN
WOMEN
JAN
3303INTERACTION
MECH
CIRCULATION
CO-12-3
CIRCULATION
ST-7-3
INTERACTION
IDF
CONFERENCE
PRIVATE
OFFICE
OPEN OFFICE
3312 PRIVATE
OFFICE
PRIVATE
OFFICE
OPEN OFFICE
PRIVATE
OFFICE
OPEN OFFICE
LAB
LAB
LAB
ELEC
SERVICE CORRIDOR
SC-1-3
CIRCULATION
CO-1-3
1 1/2" PCHWS
1 1/2" PCHWR
1 1/2" PCHWS
1 1/2" PCHWR
1 1/2" PCHWS
1 1/2" PCHWR
1 1/2" PCHWS
1 1/2" PCHWR
2" PCHWR
3" PCHWS
3" PCHWR
2" PCHWS
2" PCHWR
2" PCHWS
Q1 Q1Q1
Q1
Q4
6"ø LTCHWS
6"ø LTCHWR
6"ø MTCHWR
6"ø MTCHWS
3/4"ø CD
1"ø LTCHWR
1"ø LTCHWS
2"ø HHWR 2"ø HHWS
1 1/2"ø HHWR 1 1/2"ø HHWS
RN.1RNRMRLRKRJRHRG
37.137
32.1
CIRCULATION
CO-12-3
BREAK ROOM
OPEN OFFICE
IDF
OPEN OFFICE
OPEN OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
CONFERENCE/
PHONE
INTERACTION
MECH
3353A
MECH
3353B
LAB
LAB
LAB
LAB
4" PCHWS
4" PCHWR
1 1/2" PCHWS
1 1/2" PCHWR
1 1/2" PCHWS
1 1/2" PCHWR
1 1/2" PCHWS
1 1/2" PCHWR
1 1/2" PCHWS
1 1/2" PCHWR
1 1/2" PCHWS
1 1/2" PCHWR
4" PCHWR
4" PCHWS
3" PCHWR
3" PCHWS
Q1Q1Q1Q1Q1
M1.1.3
RN
PFHX
4" LTCHWR
4" LTCHWS
PCHWP
PCHWP
AIR SEPARATOR
AS-1
CHILLED WATER
PUMP VFD'S
ET
(BELOW)
4" PCHWS
4" PCHWR
Q2Q3
ISSUE / REVISION:
PROJECT NUMBER
DATE
DRAWN BY
CHECKED BY
NO. DESCRIPTION DATE
475 17th Street, Suite 720 Denver, Colorado 80202 Phone: 720-855-7572 www.iron-horse-architects.com
This document is an instrument of services and as such, remains the property of the Architect.
The use of this document is limited and can be extended only by written agreement with IRON
HORSE ARCHITECTS, INC.
COPYRIGHT 2015 ©
D R e v it L o c a l F ile s \2
\M
E P
-N
IS
T W in g
C u s to m iz a ti o n A
A c re e .r v t
/3
/2
:3 :5
P
M
WING 3 - LEVEL 3 -
HVAC PIPING PLAN
W
IN
G
R E
-C U
S T
O M
IZ
A
T
IO
N
M1.1.3
201009.006
AJA
3/30/16
B ro a d w a y
B o u ld e r, C O
KEYNOTES
Q1 1-1/2"PCHWS/R DN TO 4FT A.F.F. TERMINATE WITH THREADED END
BALL VALVE WITH PLUG FOR CONNECTION TO LAB EQUIPMENT BY
OTHERS.
Q2 4" LTCHWS/R AND 4" PCHWS/R DN TO HX. TRANSITION TO HX NOZZLE
CONNECTION SIZE AS CLOSE TO HX AS PRACTICAL.
Q3 CONNECT TO (E) 6" LTCHWS/R PIPING.
Q4 LOCATION OF BYPASS VALVE AND SYSTEM DP SENSOR.
SCALE: 1/8" = 1'-0"
WING 3 - LEVEL 3 - HVAC PIPING PLAN - AREA A
SCALE: 1/8" = 1'-0"
WING 3 - LEVEL 3 - HVAC PIPING PLAN - AREA B
1/4" = 1'-0"
3 ENLARGED MECHANICAL ROOM PIPING PLAN
DN
2"ø
2"ø
3"ø
RGRFRERDRCRBRANLKH
37.137
32.1
MEN
WOMEN
JAN
3303INTERACTION
MECH
CIRCULATION
CO-12-3
CIRCULATION
ST-7-3
INTERACTION
IDF
CONFERENCE
PRIVATE
OFFICE
OPEN OFFICE
3312 PRIVATE
OFFICE
PRIVATE
OFFICE
OPEN OFFICE
PRIVATE
OFFICE
OPEN OFFICE
LAB
LAB
LAB
ELEC
SERVICE CORRIDOR
SC-1-3
CIRCULATION
CO-1-3
3/4" LA
G1
3/4" LA 3/4" LA3/4" LA
G1 G1 G1
3"ø
RN.1RNRMRLRKRJRHRG
37.137
32.1
CIRCULATION
CO-12-3
BREAK ROOM
PRIVATE
OFFICE
OPEN OFFICE
IDF
OPEN OFFICE
OPEN OFFICE
PRIVATE
OFFICE
PRIVATE
OFFICE
CONFERENCE/
PHONE
INTERACTION
MECH
3353A
MECH
3353B
LAB
LAB
LAB
LAB
3/4" LA 3/4" LA 3/4" LA 3/4" LA 3/4" LA
BFP
CONNECT 1-1/2"CW &
2"D TO MECH. CHW
SYSTEM. REFER TO
DETAILS.
1 1/2" CW
1 1/2" CW
2"D DN TO FS
G1 G1 G1 G1 G1
ISSUE / REVISION:
PROJECT NUMBER
DATE
DRAWN BY
CHECKED BY
NO. DESCRIPTION DATE
475 17th Street, Suite 720 Denver, Colorado 80202 Phone: 720-855-7572 www.iron-horse-architects.com
This document is an instrument of services and as such, remains the property of the Architect.
The use of this document is limited and can be extended only by written agreement with IRON
HORSE ARCHITECTS, INC.
COPYRIGHT 2015 ©
D R e v it L o c a l F ile s \2
\M
E P
-N
IS
T W in g
C u s to m iz a ti o n A
A c re e .r v t
/3
/2
:3 :4
P
M
WING 3 - LEVEL 3 -
PLUMBING PLAN
W
IN
G
R E
-C U
S T
O M
IZ
A
T
IO
N
M1.2.3
201009.006
AJA
3/30/16
B ro a d w a y
B o u ld e r, C O
KEYNOTES
G1 3/4"LA DN TO 4FT A.F.F. TERMINATE WITH THREADED END BALL VALVE
WITH PLUG FOR CONNECTION TO LAB EQUIPMENT BY OTHERS.
SCALE: 1/8" = 1'-0"
WING 3 - LEVEL 3 - PLUMBING PLAN - AREA A
SCALE: 1/8" = 1'-0"
WING 3 - LEVEL 3 - PLUMBING PLAN - AREA B
POWER LEGEND
(Not all symbols listed below are used on these drawings)
SINGLE RECEPTACLE
DUPLEX RECEPTACLE
DOUBLE DUPLEX RECEPTACLE
DUPLEX RECEPTACLE, HALF SWITCHED
DUPLEX RECEPTACLE, CEILING MOUNTED
DUPLEX RECEPTACLE, FLOOR MOUNTED
DOUBLE DUPLEX RECEPTACLE, FLOOR MOUNTED
SPECIAL RECEPTACLE
SPECIAL RECEPTACLE, FLOOR MOUNTED
JUNCTION BOX, WALL OR CEILING MOUNTED
JUNCTION BOX, FLOOR MOUNTED
DISCONNECT SWITCH (NON-FUSED)
DISCONNECT SWITCH (FUSED)
VARIABLE SPEED DRIVE WITH DISCONNECT
UTILITY METER
ELECTRICAL PANELBOARD, CONTROL PANEL, OR OTHER
CABINET AS NOTED
PLUG MOLD (MULTI-OUTLET ASSEMBLY)
CONDUIT EXPOSED
CONDUIT TURNING DOWN
CONDUIT TURNING UP
CONDUIT CAPPED
MAIN SWITCHBOARD/DISTRIBUTION CENTER
CURRENT TRANSFORMER
GENERATOR ANNUNCIATOR PANEL
CONDUIT, UNDERGROUND OR CONCEALED IN FLOOR
AS ALLOWED PER SPECIFICATIONS
BRANCH CIRCUIT HOME RUN, NUMBER OF ARROWS INDICATES
NUMBER OF CIRCUITS, SUBSCRIPTS INDICATE PANEL & CIRCUITS
DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL
CLG
J
J
M
WM
A-1,3,5
T
CT
GANN
MOTOR
CONDUIT CONCEALED
GROUND BAR
TRANSFORMER
THERMOSTAT
SINGLE POLE SWITCH (SUBSCRIPT DENOTES SWITCHING)
TWO POLE SWITCH
THREE-WAY SWITCH
FOUR-WAY SWITCH
KEY OPERATED SWITCH
MANUAL SWITCH, HORSEPOWER RATE
DIMMER SWITCH
LOW VOLTAGE SWITCH
VARIABLE SPEED/SPEED CONTROLLER SWITCH
EXPLOSION PROOF SWITCH
THERMAL OVERLOAD SWITCH
MOMENTARY CONTACT SWITCH
COMBINATION SWITCH AND DUPLEX RECEPTACLE
PHOTOCELL
TIME CLOCK
SWITCH WITH PILOT LIGHT LOCATOR
(CONTINUOUSLY LIGHTED HANDLE)
PUSH BUTTON
OCCUPANCY SENSOR - WALL MOUNTED
IR=INFRARED, US=ULTRASONIC, DT=DUAL TECHNOLOGY
Sa
S2
S3
S4
SK
SM
SD
SPI
SP
SLV
SVS
SEP
STO
SMC
S
TC
ABBREVIATIONS LEGEND
AMPERES
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
ANNUNCIATOR
ABOVE RAISED FLOOR
AIR SAMPLING SMOKE DETECTION
AUTOMATIC TRANSFER SWITCH
BELOW FINISHED GRADE
MOTOR CIRCUIT PROTECTOR
SEE MECHANICAL EQUIPMENT SCHEDULE
MINIMUM
MAIN LUGS ONLY
MANUAL TRANSFER SWITCH
NORMALLY CLOSED
NIGHT LIGHT
NORMALLY OPEN
NOT TO SCALECONDUIT
CABLE TELEVISION
CIRCUIT BREAKER
CLOSED CIRCUIT TELEVISION
EXISTING
EMERGENCY
EMERGENCY MAIN DISTRIBUTION CENTER
EXPLOSION PROOF
EMERGENCY POWER OFF
EMERGENCY VENTILATION ON/OFF
ELECTRIC WATER COOLER
FIRE ALARM
GROUND
GENERATOR CONTROL PANEL
GROUND FAULT CIRCUIT INTERRUPTER
HAND OFF AUTOMATIC
ISOLATED GROUND
MAXIMUM
MAIN CIRCUIT BREAKER
MOTOR CONTROL CENTER
MAIN DISTRIBUTION CENTER TRANSFORMER
WEATHER PROOF
WITHOUT
WITH
VARIABLE FREQUENCY DRIVE
VOLTS
UNINTERRUPTIBLE POWER SUPPLY
UNLESS OTHERWISE NOTED
UNDER GROUND
UNDER FLOOR
TYPICAL
TRANSIENT VOLTAGE SURGE SUPPRESSER
TAMPER PROOF
SUB-DISTRIBUTION CENTER
STAND-BY
PULL BOX
ON SITE WORK FORCE
OWNER FURNISHED, OWNER INSTALLED
OWNER FURNISHED, CONTRACTOR INSTALLED
ON CENTER
ABOVE COUNTER, MOUNT HORIZONTALLY TO CENTERLINE
OF DEVICE, +6" ABOVE COUNTER OR BACK SPLASH
NOT IN CONTRACT
DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL
REFERENCE SYMBOLS LEGEND
(Not all symbols listed below are used on these drawings)
KITCHEN/OWNER/MEDICAL EQUIPMENT REFERENCE
MECHANICAL EQUIPMENT REFERENCE
EXISTING TO REMAIN
EXISTING TO BE REMOVED
EXISTING TO BE RELOCATED
EXISTING TO REMAIN - REPLACE DEVICE
DESCRIPTION DESCRIPTIONSYMBOL
A-1
LC1
UH
E
R
RL
ER
ONE-LINE DIAGRAM LEGEND
(Not all symbols listed below are used on these drawings)
DISCONNECT SWITCH
DISCONNECT SWITCH, FUSED
CIRCUIT BREAKER
PANELBOARD "A"
EM=ENERGY METER, PM=POWER METER, CM=CIRCUIT MONITOR
VOLTMETER TEST SWITCH
AMMETER TEST SWITCH
VOLTMETER
AMMETER
ENGINE GENERATOR
CONTACTOR/RELAY/CAPACITOR (AS NOTED)
TRANSFER SWITCH - ATS=AUTOMATIC, MTS=MANUAL
GROUND FAULT INTERRUPTER
TRANSIENT VOLTAGE SURGE SUPPRESSER
SHUNT TRIP
TERMINATIONS LB=LOAD BREAK, NLB=NO LOAD BREAK
DRAW-OUT DEVICE
PLUG-IN DEVICE
ELECTRICALLY OPERATEDMECHANICAL INTERLOCK
ELECTRICAL INTERLOCK, SUBSCRIPT INDICATES INTERLOCKED GROUP
KIRK KEY INTERLOCK, SUBSCRIPT INDICATES INTERLOCKED GROUP
SHORT CIRCUIT CURRENT AVAILABLE
SERVICE WEATHERHEAD
EQUIPMENT ENCLOSURE
METER
SERVICE ENTRANCE TRANSFORMER
POTENTIAL TRANSFORMER
CURRENT TRANSFORMER
STEP DOWN TRANSFORMER, ## INDICATES KVA
GROUND
FUSE
K-RATED STEP DOWN TRANSFORMER
## INDICATES KVA, # INDICATES K RATING
DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL
T
OR
ISCA
K a
E a
M
A
PM
VS
V
GFI
XXX
SYMBOL
M
(Not all symbols listed below are used on these drawings)
T
PM
CONTROLS LEGEND
DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL
(Not all symbols listed below are used on these drawings)
TK
AS
A
G
TVSS
ST
EO
P
MDC
MCC
MCB
MAX
IG
HOA
GFCI
GCP
G
FA
EWC
EVO
EPO
EP
EMDC
EM
(E)
CCTV
CB
CATV
C
BFG
ATS
ASSD
ARF
ANN
AFG
AFF
AC
A
XFMR
WP
W/O
W/
VFD
V
UPS
UON
UG
UF
TYP
TVSS
TP
SDC
SB
PB
OSWF
OFOI
OFCI
OC
NTS
NO
NL
NIC
NC
MTS
MLO
MIN
MEC
MCP
WIREMOLD (SURFACE RACEWAY)
SHADING INDICATES EMERGENCY SYSTEM
TEXT INDICATES PANEL AND CIRCUIT DESIGNATION
SWITCH WITH PILOT LIGHT
(PILOT LIGHT IS 'ON' WHEN SWITCH IS 'ON')
SEE FEEDER/MEC/TRANSFORMER SCHEDULES FOR FEEDER SIZE
KEY NOTE REFERENCE
M
LPA-# TYPICAL CIRCUIT NUMBER
TYPICAL LUMINAIRE TYPE
TG#
LIGHTING CONTROL / EQUIPMENT REFERENCE
TYPICAL ROOM REFERENCE (TOP = RM #, BOTTOM = FLR)
X
X
EXISTING TO BE REMOVED AND REPLACEDRR
ISSUE / REVISION:
PROJECT NUMBER
DATE
DRAWN BY
CHECKED BY
NO. DESCRIPTION DATE
475 17th Street, Suite 720 Denver, Colorado 80202 Phone: 720-855-7572 www.iron-horse-architects.com
This document is an instrument of services and as such, remains the property of the Architect.
The use of this document is limited and can be extended only by written agreement with IRON
HORSE ARCHITECTS, INC.
COPYRIGHT 2015 ©
D R e v it L o c a l F ile s \2
\M
E P
-N
IS
T W in g
C u s to m iz a ti o n J H a fe r.
rv t
/3
/2
:3 :5
P
M
ELECTRICAL
LEGENDS & NOTES
W
IN
G
R E
-C U
S T
O M
IZ
A
T
IO
N
E0.1.0
201009.006
JAH
JAH
03/30/16
B ro a d w a y
B o u ld e r, C O
GENERAL NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
FOR REMODELING, WORK INCLUDED IS DENOTED IN BOLD. EXISTING CONDITIONS
TO REMAIN ARE DENOTED LIGHTLY.
PROTECT STRUCTURE AND OWNER EQUIPMENT FROM DAMAGE. IMMEDIATELY
REPLACE OR REPAIR, TO ORIGINAL CONDITION, DAMAGE CAUSED BY THE
CONTRACTOR WHETHER EQUIPMENT APPEARS TO BE CURRENTLY IN USE OR NOT,
UNLESS WRITTEN AUTHORIZATION FROM THE OWNER INDICATED OTHERWISE.
PREPARE LISTING OF ALL EXISTING DAMAGED ITEMS AND SUBMIT TO OWNER PRIOR
TO BEGINNING WORK.
FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO
ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS.
COORDINATE EXACT REQUIREMENTS AND LOCATIONS OF MECHANICAL EQUIPMENT
WITH MECHANICAL DRAWINGS AND MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN
AND ORDERING MATERIALS OR EQUIPMENT.
A DETAILED WRITTEN METHOD OF PROCEDURE IS REQUIRED WHEN A
CONSTRUCTION ACTIVITY OR AN OUTAGE AFFECTS THE SAFETY OF OCCUPANTS,
TELEPHONE/DATA/FIRE ALARM EQUIPMENT OR COMPONENTS OF ANY SYSTEM
WHICH SUPPORTS THIS EQUIPMENT OR ESSENTIALLY AFFECTS THE BUILDING
MANAGEMENT, OPERATIONS OR SECURITY. SEE SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
EXISTING INFORMATION SHOWN ON THE DRAWINGS HAS BEEN TAKEN FROM
OWNER FURNISHED DRAWINGS AND/OR LIMITED FIELD OBSERVATIONS. CATOR,
RUMA & ASSOCIATES IS NOT RESPONSIBLE FOR THE ACCURACY OF ANY
INFORMATION OR THE ADEQUACY, SAFETY AND CONFORMANCE TO CURRENT
PREVAILING CODES OF ANY WORK SHOWN AS EXISTING ON THESE DRAWINGS.
PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER,
HOMERUN AND BRANCH CIRCUITS.
CONTRACTOR SHALL PROVIDE PRE-PAINTED CONDUIT. COLOR SCHEME TO MATCH
NIST'S STANDARDS AS FOLLOWS. THIS REQUIREMENT APPLIES TO BOTH FEEDERS
AND BRANCH CIRCUITS.
- BLUE: MECHANICAL CONTROLS (24-VOLT)
- WHITE: NORMAL RESEARCH POWER
- GREY (UNPAINTED): NORMAL BRANCH POWER
PROVIDE LAMACOID/PHENOLIC LABLES ON ALL PANELBOARDS, TRANSFORMERS,
DISCONNECT SWITCHES, CIRCUIT BREAKERS, VARIABLE FREQUENCY DRIVES, ETC.
TO MATCH EXISTING LABELING: PROVIDE LAMACOID/PHENOLIC LABES WITH THE
FOLLOWING COLOR SCHEME:
- BLUE WITH WHITE LETTERING: MECHANICAL CONTROL DEVICES
- WHITE WITH BLACK LETERING: NORMAL RESEARCH POWER
- GREY WITH WHITE LETTERING: NORMAL BRANCH POWER
POWER PLAN NOTES:
1.
2.
3.
4.
MAKE ALL FINAL ELECTRICAL CONNECTIONS TO EQUIPMENT REQUIRING
ELECTRICAL CONNECTION. THIS SHALL INCLUDE BUT NOT BE LIMITED TO ALL
MECHANICAL AND OTHER EQUIPMENT INCLUDED IN THIS PROJECT.
COORDINATE EXACT REQUIREMENTS AND LOCATIONS OF MECHANICAL
EQUIPMENT WITH MECHANICAL DRAWINGS AND MECHANICAL CONTRACTOR
PRIOR TO ROUGH-IN.
PROVIDE FUSES SIZED PER EQUIPMENT MANUFACTURER'S REQUIREMENTS.
DISCONNECT SWITCH LOCATIONS ARE SHOWN DIAGRAMMATICALLY AND SHALL
BE INSTALLED IN ACCESSIBLE LOCATIONS TO SUIT EQUIPMENT AND SPACE.
DISCONNECT SWITCHES SHALL BE WITHIN SIGHT OF THE EQUIPMENT THEY
SERVE AND MOUNTED AT 6'-3", MAXIMUM, TO TOP OF CABINET. MAINTAIN NEC
WORK SPACE REQUIREMENTS.
Key # Item HP FLA Load Eq Load (VA) Voltage
Feeders Protection
NotesWire Ground Conduit Breaker Disconnect Fuse
PCHWP 1 PROCESS CHILLED WATER
PUMP
15 0 A 0 VA 16732 VA 480V 3ph 3#10 #10G 3/4” 40 A 60 A 35 A 2
PCHWP 2 PROCESS CHILLED WATER
PUMP
15 0 A 0 VA 16732 VA 480V 3ph 3#10 #10G 3/4” 40 A 60 A 35 A 2
M E C H A N I C A L E Q U I P M E N T S C H E D U L E
NOTES:
1. REFER TO FLOOR PLAN FOR EQUIPMENT CIRCUITING.
2. VFD (VARIABLE FREQUENCY DRIVE) FURNISHED WITH EQUIPMENT. PROVIDE
DISCONNECTING MEANS AS INDICATED. DISCONNECTING MEANS SHALL BE
EQUIPPED WITH AUXILARY CONTACTS FOR VFD SHUTDOWN/COMMUNICATION.
COORDINATE WITH THE MECHANICAL CONTRACTOR.
BUS DUCT LOAD SUMMARY (DB3-1A)
BUS DUCT LOAD SUMMARY (DB3-1B)
BUS DUCT RATING 600 AMPS
* EXISTING LOAD (PANEL L3C-A1) 28.2 KVA
* EXISTING LOAD (PANEL L3C-A2) 30.0 KVA
** NEW LOAD ADDED (PANEL L3C-A3) 34.5 KVA
** NEW LOAD ADDED (PANEL L3C-A4) 51.8 KVA
TOTAL LOAD 144.5 KVA
( 174 AMPS)
* EXISTING LOAD TAKEN FROM THE "CONNECTED LOAD"
INDICATED ON THE ORIGINAL CONTRUCTION DOCUMENTS.
** NEW LOAD IS ANTICIPATED FOR FINAL BUILDOUT OF LAB
SPACE UNDER FUTURE PHASE OF WORK.
BUS DUCT RATING 600 AMPS
* EXISTING LOAD (PANEL L3C-B2) 19.4 KVA
* EXISTING LOAD (PANEL L3C-B3) 27.2 KVA
* EXISTING LOAD (PANEL L3C-B4) 29.0 KVA
** NEW LOAD ADDED (PANEL L3C-B5) 63.0 KVA
** NEW LOAD ADDED (PANEL L3C-A6) 51.8 KVA
TOTAL LOAD 190.4 KVA
( 229 AMPS)
* EXISTING LOAD TAKEN FROM THE "CONNECTED LOAD"
INDICATED ON THE ORIGINAL CONTRUCTION DOCUMENTS.
** NEW LOAD IS ANTICIPATED FOR FINAL BUILDOUT OF LAB
SPACE UNDER FUTURE PHASE OF WORK.
FEEDERS FROM SPOT NETWORK
DISTRIBUTION BOARD
(WING 3/SPINE)
SES-H3PDU-A (WING 3/SPINE)
ELECTRICAL ROOM #3351
1,600AMPS 277/480V., 3PH, 4W, NEMA 1
65,000 SCIR MIN
600/3
DB3-1A - 600A NORMAL BUS WING 3
DB3-2A - 600A
NORMAL BUS SPINE
DB3-1B - 600A NORMAL BUS WING 3
400/3 225/3
1,600AMP
800/3
SPARE
ST GFP
H3SB-A1
400A
MCB
SES-H3PDU-B (WING 3/SPINE)
ELECTRICAL ROOM #3351
1,600AMPS 277/480V., 3PH, 4W, NEMA 1
65,000 SCIR MIN
1,600AMP
STGFP800/3
H3LS-A1
225A
MLO
45KVA
225/3
H3EQ-B1
225A
MLO
L3LS-A1
150A
MCB
M M
75KVA
K-RATED
L3SB-B1
225A
MCB
600/3
H3SB-B1
600A
MCB
ST
GFP
ST
GFP
ST
GFP
60/3
TVSS
60/3
TVSS
SPARE
N N
G G
GROUNDED
CONDUCTOR
GROUNDED
CONDUCTOR
225/3
SPARE
SPARE
225/3600/3600/3
100/3AMP
75KVA
K-RATED
L3C-A1 225A
MCB
X
100/3AMP
75KVA
K-RATED
L3C-A2 225A
MCB
X
100/3AMP
75KVA
K-RATED
L3C-B2 225A
MCB
X
100/3AMP
75KVA
K-RATED
L3C-B3 225A
MCB
X
100/3AMP
75KVA
K-RATED
L3C-B4 225A
MCB
X
75KVA
K-RATED
L3C-B1 225A
MCB
110/3
T3C-A1
T3C-B2
T3SB-B1
T3C-B3
T3C-B4
T3LS-A1
T3C-A2
ST
GFP
600/3
T3C-B5
FUTURE
STANDBY BUSWAY
CT
125/3AMP
75KVA
K-RATED
FUTURE
SPINE
225A
MCB
X
T3C-X
H3-L1 225A
MCB
LIGHTING
75KVA
L3-B2 225A
MCB
110/3
T3-B1
600/3AMP
H3SB-A2
400A
MLO
X
5341A
X
5341A X31281A
X
5133A
51035A
X
X 51035A
X
51035A
3385A 3385A 3385A 3329A 3329A
3329A
X X
49844A
X
41866A
X
49844A
X
31281A
X
4185A
H3SB-B2
600A
MLO
51035A
X
FTL
60527A
X
70/3
EWH-1
WATER
HEATER
X
125/3
200/3AMP
J
3840A
X
(FUTURE)
FUTURE
STANDBY BUSWAY
51035A
60527A
TYP TYP
EQUIPMENT GROUND FAULT
PROTECTION
SHUNT-TRIP CIRCUIT INTERRUPTERST
GFP
ONE-LINE SYMBOLS
VFD
MOTOR I.D.; I.E., RAF-A-2, 30HP
VARIABLE FREQUENCY DRIVE
CT ELECTRICAL BUS CENTER TAP
M ELECTRICAL METER
FAULT CURRECT NOTE:
FAULT CURRENT VALUES FOR THIS PROJECT HAVE BEEN OBTAINED
BY USING SKM SYSTEMS ANALYSIS, INC. SOFTWEAR.
PRELIMINARY COORDINATION STUDY RESULTS (PROVIDE FINAL STUDY
WITH EQUIPTMENT INSTALLED):
• PLUG IN CIRCUIT BREAKERS FOR THE 600A BUSDUCT SHALL HAVE FIELD-ADJUSTABLE
TIME CURRENT CHARACTERISTICS.
• MAIN CIRCUIT BREAKERS AND FEEDER CIRCUIT BREAKERS 100A AND LARGER SHALL HAVE
FIELD-ADJUSTABLE TIME CURRENT CHARACTERISTICS (LSI TYPE BREAKERS).
SELECTIVE COORDINATION NOTE:
THE ELECTRICAL CONTRACTOR SHALL SUBMIT A COORDINATION STUDY PROVIDED BY SELECTED
EQUIPMENT MANUFACTURER IN COMPLIANCE WITH NEC ARTICLES 620.62, 700.27, AND 701.18 FOR SLECTIVE COORDINATION OF ELEVATORS, EMERGENCY SYTEMS AND LEGALLY REQUIRED STANDBY SYSTEMS. THIS REPORT SHALL BE SUBMITTED, REVIEWED AND APPROVED BY THE ENGINEER OF RECORD PRIOR TO THE ORDER OF EQUIPMENT, PURCHASE AND INSTALL. REFER TO SPECIFICAITON
SECTION 26 05 73 FOR ADDITONAL INFORMATION.
(FUTURE)
(FUTURE)
(FUTURE)
H3C-B1 600A
MLO
PROVIDE CONNECTION TO AVAILABLE "SPARE"
CIRCUIT BREAKER. SET CIRCUIT BREAKER TRIP
AT 600-AMPS.
2[4#350, 1#1G, 3"C.]
100/3AMP
75KVA
K-RATED
L3C-B6 225A
MCB
T3C-B6
100/3AMP
75KVA
K-RATED
L3C-A3 225A
MCB
T3C-A3
100/3AMP
75KVA
K-RATED
L3C-A4 225A
MCB
T3C-A4
100/3AMP
75KVA
K-RATED
L3C-B5 225A
MCB
T3C-B5T3C-B7
3#1, 1#6G, 1-1/2"C.
(TYPICAL)
4#250, 1#2G, 1#2IG, 2-1/2"C.
(TYPICAL)
1#2, 3/4"C.
(TYPICAL)
AREA OF WORK AREA OF WORK AREA OF WORK
FUSED FUSED
FUSED
FUSED
4#250, 1#2G, 1#2IG, 2-1/2"C.
(TYPICAL)
3#1, 1#6G, 1-1/2"C.
(TYPICAL)
1#2, 3/4"C.
(TYPICAL)
X
3329A
X
3329A
X
3329A
X
3329A
X51035A
PROVIDE PANELBOARD WITH
ISOLATED GROUND (IG) BUS,
SPD AND POWER MONITOR
PROVIDE PANELBOARD WITH
ISOLATED GROUND (IG) BUS,
SPD AND POWER MONITOR
PROVIDE PANELBOARD WITH
SPD AND POWER MONITOR
ONE-LINE DIAGRAM NOTES:
1.
2.
3.
PANELBOARDS INDICATED ON ONE LINE DIAGRAMS DO NOT SHOW ALL
BRANCH CIRCUITS. REFER TO PANELBOARD SCHEDULE(S).
NEW WORK REQUIRED BY THE CONTRACTOR IS INDICATED BY THE SCOPE
OF WORK BOXES.
NEW PANELBOARDS SHALL BE PROVIDE WITH POWER MONITORS (SIEMENS
#SENTRON PAC3200) AND INTEGRAL SURGE PROTECTIVE DEVICES TO
MATCH EXISTING INSTALLED EQUIPMENT. PROVIDE LOW VOLTAGE
CONNECTION FROM THE POWER MONITORS TO THE EXISTING POWER
MONITORING EQUIPMENT LOCATED IN THE MAIN ELECTRIC ROOM. FIELD
VERIFY EXACT REQUIREMENTS.
ISSUE / REVISION:
PROJECT NUMBER
DATE
DRAWN BY
CHECKED BY
NO. DESCRIPTION DATE
475 17th Street, Suite 720 Denver, Colorado 80202 Phone: 720-855-7572 www.iron-horse-architects.com
This document is an instrument of services and as such, remains the property of the Architect.
The use of this document is limited and can be extended only by written agreement with IRON
HORSE ARCHITECTS, INC.
COPYRIGHT 2015 ©
D R e v it L o c a l F ile s \2
\M
E P
-N
IS
T W in g
C u s to m iz a ti o n J H a fe r.
rv t
/3
/2
:3 :5
P
M
ELECTRICAL
ONE-LINE DIAGRAM
W
IN
G
R E
-C U
S T
O M
IZ
A
T
IO
N
E0.2.0
201009.006
JAH
JAH
03/30/16
B ro a d w a y
B o u ld e r, C O
SCALE: 1" = 1'-0"
ELECTRICAL ONE-LINE DIAGRAM
PANELEXISTING " H3SB-B1 "
Panel Notes:
600 A MAIN CIRCUIT BREAKER VOLTAGE 277 / 480 V 1. NEW LOAD ON EXISTING CIRCUIT BREAKER. 7. PROVIDE GFCI CIRCUIT BREAKER.
600 A BUS PHASE 3 PH 2. PROVIDE CIRCUIT BREAKER IN SPACE TO MATCH EXISTING. 8. PROVIDE SHUNT-TRIP CIRCUIT BREAKER.
WIRE 4 W 3. REPLACE EXISTING CIRCUIT BREAKER WITH NEW CIRCUIT BREAKER.
MFR : 4. EXISTING LOAD ON NEW CIRCUIT BREAKER. LOAD IS ESTIMATED.
MTG. : SURFACE 65,000 AMPERE SHORT CIRCUIT RATING (FULLY RATED) 5. EXISTING LOAD REMOVED.
6. PROVIDE 30mA GROUND FAULT CIRCUIT BREAKER.
BREAKER BREAKER
NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TOTAL AMP / P CCT PH CCT AMP / P TOTAL GENERAL OTHER MOTORS RECEPT LTG DESCRIPTION NOTE
VFD/CWP-3-1 2,922 2922 20 / 1 A 2 20 / 2922 2,922 VFD/CWP-3-2
" 2,922 2922 / 3 B 4 / 2922 2,922 "
" 2,922 2922 / 3 5 C 6 / 3 2922 2,922 "
DDC-1 167 167 20 / 7 A 8 20 / 167 167 DDC-2
" 167 167 / 9 B 10 / 167 167 "
" 167 167 / 3 11 C 12 / 3 167 167 "
DDC-3 167 167 20 / 13 A 14 20 / 167 167 DDC-4
" 167 167 / 15 B 16 / 167 167 "
" 167 167 / 3 17 C 18 / 3 167 167 "
FUTURE CONTROL 167 167 20 / 19 A 20 20 / 167 167 FUTURE CONTROL
PANEL 1 167 167 / 21 B 22 / 167 167 PANEL 2
" 167 167 / 3 23 C 24 / 3 167 167 "
FC-3353B MECH 3353 665 665 20 / 1 25 A 26 20 / 2922 2,922 VFD/CHWP-3-2
SPACE 0 / 27 B 28 / 2922 2,922 "
SPACE 0 / 29 C 30 / 3 2922 2,922 "
VFD/CHWP-3-3 2,922 2922 20 / 31 A 32 40 / 5577 5,577 VFD/PCHWP-1 2
" 2,922 2922 / 33 B 34 / 5577 5,577 (MECH 3353B)
" 2,922 2922 / 3 35 C 36 / 3 5577 5,577 "
3 VFD/PCHWP-2 5,577 5577 40 / 37 A 38 / 6306 6,306 PANEL H3SB-B2
(MECH 3353B) 5,577 5577 / 39 B 40 / 6064 6,064 (VIA FEED THRU
" 5,577 5577 / 3 41 C 42 / 5944 5,944 LUGS)
PHASE LOADING SUMMARY PANEL LOADING SUMMARY
LOAD TYPE (VA) PH A PH B PH C LOAD TYPE CONNECTED NEC CALCULATED POWER DEMAND
LIGHTING 0.0 0.0 0.0 LOAD KVA DEMAND LOAD FACTOR LOAD KW PANEL
RECEPTACLES 0.0 0.0 0.0 CONNECTED PF=
MOTORS 29,813.0 28,906.0 28,786.0 LIGHTING 0.0 KVA x 125% = 0.0 KVA x 95% = 0.0 KW 90%
OTHER 0.0 0.0 0.0 RECEPTACLES
GENERAL 1,002.0 1,002.0 1,002.0 FIRST 10 KVA 0.0 KVA x 100% = 0.0 KVA x 100% = 0.0 KW CONNECTED
TOTAL (VA) 30,815.0 29,908.0 29,788.0 REMAINDER 0.0 KVA x 50% = 0.0 KVA x 100% = 0.0 KW AMPACITY =
MOTORS 108.9
NEC CALCULATED LARGEST 16.7 KVA x 125% = 20.9 KVA x 90% = 18.8 KW
PHASE AMPACITY 116.7 113.3 112.7 REMAINDER 70.8 KVA x 100% = 70.8 KVA x 90% = 63.7 KW NEC DEMAND
OTHER 0.0 KVA x 125% = 0.0 KVA x 100% = 0.0 KW AMPACITY =
600.0 GENERAL 3.0 KVA x 100% = 3.0 KVA x 100% = 3.0 KW 113.9
PHASE BALANCE A-B B-C C-A
3% 0% 3% TOTAL 90.5 KVA 94.7 KVA 85.5 KW
GENERAL NOTES:
' PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT.
' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL.
PANELNEW " H3C-B1 " SERVES LAB #3317
Panel Notes:
600 A M.L.O. VOLTAGE 277 / 480 V 1. PANELBOARD SCHEDULE SHOWN FOR REQUIRED RATINGS, CIRCUIT BREAKER SIZES
600 A BUS PHASE 3 PH AND CIRCUIT BREAKER QUANTITIES ONLY.
WIRE 4 W 2. LOAD IS ESTIMATED.
MFR : 3. PROVIDE PANELBOARD WITH INTEGRAL SURGE PROTECTIVE DEVICE
MTG. : SURFACE 65,000 AMPERE SHORT CIRCUIT RATING (FULLY RATED) 4. PROVIDE POWER MONITOR (SIEMENS #SENTROL PAC 3200) TO MATCH EXISTING POWER MONITORING DEVICES.
BREAKER BREAKER
NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TOTAL AMP / P CCT PH CCT AMP / P TOTAL GENERAL OTHER MOTORS RECEPT LTG DESCRIPTION NOTE
2 LAB 3317 EQUIP 20,000 20000 100 / 1 A 2 100 / 20000 20,000 LAB 3317 EQUIP 2
" 20,000 20000 / 3 B 4 / 20000 20,000 "
" 20,000 20000 / 3 5 C 6 / 3 20000 20,000 "
2 LAB 3317 EQUIP 9,500 9500 50 / 7 A 8 50 / 9500 9,500 LAB 3317 EQUIP 2
" 9,500 9500 / 9 B 10 / 9500 9,500 "
" 9,500 9500 / 3 11 C 12 / 3 9500 9,500 "
2 LAB 3317 EQUIP 9,500 9500 50 / 13 A 14 50 / 9500 9,500 LAB 3317 EQUIP 2
" 9,500 9500 / 15 B 16 / 9500 9,500 "
" 9,500 9500 / 3 17 C 18 / 3 9500 9,500 "
SPACE 0 / 19 A 20 / 0 SPACE
SPACE 0 / 21 B 22 / 0 SPACE
SPACE 0 / 23 C 24 / 0 SPACE
SPACE 0 / 25 A 26 / 0 SPACE
SPACE 0 / 27 B 28 / 0 SPACE
SPACE 0 / 29 C 30 / 0 SPACE
SPACE 0 / 31 A 32 / 0 SPACE
SPACE 0 / 33 B 34 / 0 SPACE
SPACE 0 / 35 C 36 / 0 SPACE
SPACE 0 / 37 A 38 / 0 SPACE
SPACE 0 / 39 B 40 / 0 SPACE
SPACE 0 / 41 C 42 / 0 SPACE
PHASE LOADING SUMMARY PANEL LOADING SUMMARY
LOAD TYPE (VA) PH A PH B PH C LOAD TYPE CONNECTED NEC CALCULATED POWER DEMAND
LIGHTING 0.0 0.0 0.0 LOAD KVA DEMAND LOAD FACTOR LOAD KW PANEL
RECEPTACLES 0.0 0.0 0.0 CONNECTED PF=
MOTORS 0.0 0.0 0.0 LIGHTING 0.0 KVA x 125% = 0.0 KVA x 95% = 0.0 KW 100%
OTHER 0.0 0.0 0.0 RECEPTACLES
GENERAL 78,000.0 78,000.0 78,000.0 FIRST 10 KVA 0.0 KVA x 100% = 0.0 KVA x 100% = 0.0 KW CONNECTED
TOTAL (VA) 78,000.0 78,000.0 78,000.0 REMAINDER 0.0 KVA x 50% = 0.0 KVA x 100% = 0.0 KW AMPACITY =
MOTORS 281.5
NEC CALCULATED LARGEST 0.0 KVA x 125% = 0.0 KVA x 90% = 0.0 KW
PHASE AMPACITY 281.1 281.1 281.1 REMAINDER 0.0 KVA x 100% = 0.0 KVA x 90% = 0.0 KW NEC DEMAND
OTHER 0.0 KVA x 125% = 0.0 KVA x 100% = 0.0 KW AMPACITY =
600.0 GENERAL 234.0 KVA x 100% = 234.0 KVA x 100% = 234.0 KW 281.5
PHASE BALANCE A-B B-C C-A
0% 0% 0% TOTAL 234.0 KVA 234.0 KVA 234.0 KW
GENERAL NOTES:
' PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT.
' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL.
PANELNEW " L3C-A3 " SERVES LAB #3317
Panel Notes:
225 A MAIN CIRCUIT BREAKER VOLTAGE 120 / 208 V 1. PANELBOARD SCHEDULE SHOWN FOR REQUIRED RATINGS, CIRCUIT BREAKER SIZES
225 A BUS PHASE 3 PH AND CIRCUIT BREAKER QUANTITIES ONLY.
WIRE 4 W 2. LOAD IS ESTIMATED.
MFR : 3. PROVIDE PANELBOARD WITH INTEGRAL SURGE PROTECTIVE DEVICE
MTG. : SURFACE 10,000 AMPERE SHORT CIRCUIT RATING (FULLY RATED) 4. PROVIDE POWER MONITOR (SIEMENS #SENTROL PAC 3200) TO MATCH EXISTING POWER MONITORING DEVICES.
BREAKER BREAKER
NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TOTAL AMP / P CCT PH CCT AMP / P TOTAL GENERAL OTHER MOTORS RECEPT LTG DESCRIPTION NOTE
2 LAB 3317 EQUIP 2,878 2878 30 / 1 A 2 30 / 2878 2,878 LAB 3317 EQUIP 2
" 2,878 2878 / 3 B 4 / 2878 2,878 "
" 2,878 2878 / 3 5 C 6 / 3 2878 2,878 "
2 LAB 3317 EQUIP 2,878 2878 30 / 7 A 8 30 / 2878 2,878 LAB 3317 EQUIP 2
" 2,878 2878 / 9 B 10 / 2878 2,878 "
" 2,878 2878 / 3 11 C 12 / 3 2878 2,878 "
SPACE 0 / 13 A 14 / 0 SPACE
SPACE 0 / 15 B 16 / 0 SPACE
SPACE 0 / 17 C 18 / 0 SPACE
SPACE 0 / 19 A 20 / 0 SPACE
SPACE 0 / 21 B 22 / 0 SPACE
SPACE 0 / 23 C 24 / 0 SPACE
SPACE 0 / 25 A 26 / 0 SPACE
SPACE 0 / 27 B 28 / 0 SPACE
SPACE 0 / 29 C 30 / 0 SPACE
SPACE 0 / 31 A 32 / 0 SPACE
SPACE 0 / 33 B 34 / 0 SPACE
SPACE 0 / 35 C 36 / 0 SPACE
SPACE 0 / 37 A 38 / 0 SPACE
SPACE 0 / 39 B 40 / 0 SPACE
SPACE 0 / 41 C 42 / 0 SPACE
PHASE LOADING SUMMARY PANEL LOADING SUMMARY
LOAD TYPE (VA) PH A PH B PH C LOAD TYPE CONNECTED NEC CALCULATED POWER DEMAND
LIGHTING 0.0 0.0 0.0 LOAD KVA DEMAND LOAD FACTOR LOAD KW PANEL
RECEPTACLES 0.0 0.0 0.0 CONNECTED PF=
MOTORS 0.0 0.0 0.0 LIGHTING 0.0 KVA x 125% = 0.0 KVA x 95% = 0.0 KW 100%
OTHER 0.0 0.0 0.0 RECEPTACLES
GENERAL 11,512.0 11,512.0 11,512.0 FIRST 10 KVA 0.0 KVA x 100% = 0.0 KVA x 100% = 0.0 KW CONNECTED
TOTAL (VA) 11,512.0 11,512.0 11,512.0 REMAINDER 0.0 KVA x 50% = 0.0 KVA x 100% = 0.0 KW AMPACITY =
MOTORS 95.9
NEC CALCULATED LARGEST 0.0 KVA x 125% = 0.0 KVA x 90% = 0.0 KW
PHASE AMPACITY 95.7 95.7 95.7 REMAINDER 0.0 KVA x 100% = 0.0 KVA x 90% = 0.0 KW NEC DEMAND
OTHER 0.0 KVA x 125% = 0.0 KVA x 100% = 0.0 KW AMPACITY =
225.0 GENERAL 34.5 KVA x 100% = 34.5 KVA x 100% = 34.5 KW 95.9
PHASE BALANCE A-B B-C C-A
0% 0% 0% TOTAL 34.5 KVA 34.5 KVA 34.5 KW
GENERAL NOTES:
' PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT.
' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL.
PANELNEW " L3C-A4 " SERVES LAB #3321/3325
Panel Notes:
225 A MAIN CIRCUIT BREAKER VOLTAGE 120 / 208 V 1. PANELBOARD SCHEDULE SHOWN FOR REQUIRED RATINGS, CIRCUIT BREAKER SIZES
225 A BUS PHASE 3 PH AND CIRCUIT BREAKER QUANTITIES ONLY.
WIRE 4 W 2. LOAD IS ESTIMATED.
MFR : 3. PROVIDE PANELBOARD WITH INTEGRAL SURGE PROTECTIVE DEVICE
MTG. : SURFACE 10,000 AMPERE SHORT CIRCUIT RATING (FULLY RATED) 4. PROVIDE POWER MONITOR (SIEMENS #SENTROL PAC 3200) TO MATCH EXISTING POWER MONITORING DEVICES.
BREAKER BREAKER
NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TOTAL AMP / P CCT PH CCT AMP / P TOTAL GENERAL OTHER MOTORS RECEPT LTG DESCRIPTION NOTE
LAB 3325 EQUIP 2,878 2878 50 / 1 A 2 50 / 2878 2,878 LAB 3325 EQUIP
" 2,878 2878 / 3 B 4 / 2878 2,878 "
" 2,878 2878 / 3 5 C 6 / 3 2878 2,878 "
LAB 3325 EQUIP 2,878 2878 30 / 7 A 8 30 / 2878 2,878 LAB 3325 EQUIP
" 2,878 2878 / 9 B 10 / 2878 2,878 "
" 2,878 2878 / 3 11 C 12 / 3 2878 2,878 "
LAB 3321 EQUIP 2,878 2878 30 / 13 A 14 30 / 2878 2,878 LAB 3321 EQUIP
" 2,878 2878 / 15 B 16 / 2878 2,878 "
" 2,878 2878 / 3 17 C 18 / 3 2878 2,878 "
SPACE 0 / 19 A 20 / 0 SPACE
SPACE 0 / 21 B 22 / 0 SPACE
SPACE 0 / 23 C 24 / 0 SPACE
SPACE 0 / 25 A 26 / 0 SPACE
SPACE 0 / 27 B 28 / 0 SPACE
SPACE 0 / 29 C 30 / 0 SPACE
SPACE 0 / 31 A 32 / 0 SPACE
SPACE 0 / 33 B 34 / 0 SPACE
SPACE 0 / 35 C 36 / 0 SPACE
SPACE 0 / 37 A 38 / 0 SPACE
SPACE 0 / 39 B 40 / 0 SPACE
SPACE 0 / 41 C 42 / 0 SPACE
PHASE LOADING SUMMARY PANEL LOADING SUMMARY
LOAD TYPE (VA) PH A PH B PH C LOAD TYPE CONNECTED NEC CALCULATED POWER DEMAND
LIGHTING 0.0 0.0 0.0 LOAD KVA DEMAND LOAD FACTOR LOAD KW PANEL
RECEPTACLES 0.0 0.0 0.0 CONNECTED PF=
MOTORS 0.0 0.0 0.0 LIGHTING 0.0 KVA x 125% = 0.0 KVA x 95% = 0.0 KW 100%
OTHER 0.0 0.0 0.0 RECEPTACLES
GENERAL 17,268.0 17,268.0 17,268.0 FIRST 10 KVA 0.0 KVA x 100% = 0.0 KVA x 100% = 0.0 KW CONNECTED
TOTAL (VA) 17,268.0 17,268.0 17,268.0 REMAINDER 0.0 KVA x 50% = 0.0 KVA x 100% = 0.0 KW AMPACITY =
MOTORS 143.8
NEC CALCULATED LARGEST 0.0 KVA x 125% = 0.0 KVA x 90% = 0.0 KW
PHASE AMPACITY 143.6 143.6 143.6 REMAINDER 0.0 KVA x 100% = 0.0 KVA x 90% = 0.0 KW NEC DEMAND
OTHER 0.0 KVA x 125% = 0.0 KVA x 100% = 0.0 KW AMPACITY =
225.0 GENERAL 51.8 KVA x 100% = 51.8 KVA x 100% = 51.8 KW 143.8
PHASE BALANCE A-B B-C C-A
0% 0% 0% TOTAL 51.8 KVA 51.8 KVA 51.8 KW
GENERAL NOTES:
' PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT.
' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL.
PANELNEW " L3C-B5 " SERVES LAB #3337
Panel Notes:
225 A MAIN CIRCUIT BREAKER VOLTAGE 120 / 208 V 1. PANELBOARD SCHEDULE SHOWN FOR REQUIRED RATINGS, CIRCUIT BREAKER SIZES
225 A BUS PHASE 3 PH AND CIRCUIT BREAKER QUANTITIES ONLY.
WIRE 4 W 2. LOAD IS ESTIMATED.
MFR : 3. PROVIDE PANELBOARD WITH INTEGRAL SURGE PROTECTIVE DEVICE
MTG. : SURFACE 10,000 AMPERE SHORT CIRCUIT RATING (FULLY RATED) 4. PROVIDE POWER MONITOR (SIEMENS #SENTROL PAC 3200) TO MATCH EXISTING POWER MONITORING DEVICES.
BREAKER BREAKER
NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TOTAL AMP / P CCT PH CCT AMP / P TOTAL GENERAL OTHER MOTORS RECEPT LTG DESCRIPTION NOTE
LAB 3337 EQUIP 1,500 1500 20 / 1 1 A 2 20 / 1 1500 1,500 LAB 3337 EQUIP
LAB 3337 EQUIP 1,500 1500 20 / 1 3 B 4 20 / 1 1500 1,500 LAB 3337 EQUIP
LAB 3337 EQUIP 1,500 1500 20 / 1 5 C 6 20 / 1 1500 1,500 LAB 3337 EQUIP
LAB 3337 EQUIP 1,500 1500 20 / 1 7 A 8 20 / 1 1500 1,500 LAB 3337 EQUIP
LAB 3337 EQUIP 1,500 1500 20 / 1 9 B 10 20 / 1 1500 1,500 LAB 3337 EQUIP
LAB 3337 EQUIP 1,500 1500 20 / 1 11 C 12 20 / 1 1500 1,500 LAB 3337 EQUIP
LAB 3337 EQUIP 1,500 1500 20 / 1 13 A 14 20 / 1 1500 1,500 LAB 3337 EQUIP
LAB 3337 EQUIP 1,500 1500 20 / 1 15 B 16 20 / 1 1500 1,500 LAB 3337 EQUIP
LAB 3337 EQUIP 1,500 1500 20 / 1 17 C 18 20 / 1 1500 1,500 LAB 3337 EQUIP
LAB 3337 EQUIP 1,500 1500 20 / 1 19 A 20 20 / 1 1500 1,500 LAB 3337 EQUIP
LAB 3337 EQUIP 1,500 1500 20 / 1 21 B 22 20 / 1 1500 1,500 LAB 3337 EQUIP
LAB 3337 EQUIP 2,500 2500 30 / 23 C 24 30 / 2500 2,500 LAB 3337 EQUIP
" 2,500 2500 / 2 25 A 26 / 2 2500 2,500 "
LAB 3337 EQUIP 2,500 2500 30 / 27 B 28 30 / 2500 2,500 LAB 3337 EQUIP
" 2,500 2500 / 2 29 C 30 / 2 2500 2,500 "
LAB 3337 EQUIP 2,500 2500 30 / 31 A 32 30 / 2500 2,500 LAB 3337 EQUIP
" 2,500 2500 / 2 33 B 34 / 2 2500 2,500 "
SPACE 0 / 35 C 36 / 0 SPACE
SPACE 0 / 37 A 38 / 0 SPACE
SPACE 0 / 39 B 40 / 0 SPACE
SPACE 0 / 41 C 42 / 0 SPACE
PHASE LOADING SUMMARY PANEL LOADING SUMMARY
LOAD TYPE (VA) PH A PH B PH C LOAD TYPE CONNECTED NEC CALCULATED POWER DEMAND
LIGHTING 0.0 0.0 0.0 LOAD KVA DEMAND LOAD FACTOR LOAD KW PANEL
RECEPTACLES 0.0 0.0 0.0 CONNECTED PF=
MOTORS 0.0 0.0 0.0 LIGHTING 0.0 KVA x 125% = 0.0 KVA x 95% = 0.0 KW 100%
OTHER 0.0 0.0 0.0 RECEPTACLES
GENERAL 22,000.0 22,000.0 19,000.0 FIRST 10 KVA 0.0 KVA x 100% = 0.0 KVA x 100% = 0.0 KW CONNECTED
TOTAL (VA) 22,000.0 22,000.0 19,000.0 REMAINDER 0.0 KVA x 50% = 0.0 KVA x 100% = 0.0 KW AMPACITY =
MOTORS 174.9
NEC CALCULATED LARGEST 0.0 KVA x 125% = 0.0 KVA x 90% = 0.0 KW
PHASE AMPACITY 183.0 183.0 158.0 REMAINDER 0.0 KVA x 100% = 0.0 KVA x 90% = 0.0 KW NEC DEMAND
OTHER 0.0 KVA x 125% = 0.0 KVA x 100% = 0.0 KW AMPACITY =
225.0 GENERAL 63.0 KVA x 100% = 63.0 KVA x 100% = 63.0 KW 174.9
PHASE BALANCE A-B B-C C-A
0% 16% 16% TOTAL 63.0 KVA 63.0 KVA 63.0 KW
GENERAL NOTES:
' PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT.
' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL.
PANELNEW " L3C-B6 " SERVES LAB #3341/3349
Panel Notes:
225 A MAIN CIRCUIT BREAKER VOLTAGE 120 / 208 V 1. PANELBOARD SCHEDULE SHOWN FOR REQUIRED RATINGS, CIRCUIT BREAKER SIZES
225 A BUS PHASE 3 PH AND CIRCUIT BREAKER QUANTITIES ONLY.
WIRE 4 W 2. LOAD IS ESTIMATED.
MFR : 3. PROVIDE PANELBOARD WITH INTEGRAL SURGE PROTECTIVE DEVICE
MTG. : SURFACE 10,000 AMPERE SHORT CIRCUIT RATING (FULLY RATED) 4. PROVIDE POWER MONITOR (SIEMENS #SENTROL PAC 3200) TO MATCH EXISTING POWER MONITORING DEVICES.
BREAKER BREAKER
NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TOTAL AMP / P CCT PH CCT AMP / P TOTAL GENERAL OTHER MOTORS RECEPT LTG DESCRIPTION NOTE
LAB 3341 EQUIP 2,878 2878 30 / 1 A 2 30 / 2878 2,878 LAB 3341 EQUIP
" 2,878 2878 / 3 B 4 / 2878 2,878 "
" 2,878 2878 / 3 5 C 6 / 3 2878 2,878 "
LAB 3341 EQUIP 2,878 2878 30 / 7 A 8 30 / 2878 2,878 LAB 3341 EQUIP
" 2,878 2878 / 9 B 10 / 2878 2,878 "
" 2,878 2878 / 3 11 C 12 / 3 2878 2,878 "
LAB 3349 EQUIP 2,878 2878 30 / 13 A 14 30 / 2878 2,878 LAB 3349 EQUIP
" 2,878 2878 / 15 B 16 / 2878 2,878 "
" 2,878 2878 / 3 17 C 18 / 3 2878 2,878 "
SPACE 0 / 19 A 20 / 0 SPACE
SPACE 0 / 21 B 22 / 0 SPACE
SPACE 0 / 23 C 24 / 0 SPACE
SPACE 0 / 25 A 26 / 0 SPACE
SPACE 0 / 27 B 28 / 0 SPACE
SPACE 0 / 29 C 30 / 0 SPACE
SPACE 0 / 31 A 32 / 0 SPACE
SPACE 0 / 33 B 34 / 0 SPACE
SPACE 0 / 35 C 36 / 0 SPACE
SPACE 0 / 37 A 38 / 0 SPACE
SPACE 0 / 39 B 40 / 0 SPACE
SPACE 0 / 41 C 42 / 0 SPACE
PHASE LOADING SUMMARY PANEL LOADING SUMMARY
LOAD TYPE (VA) PH A PH B PH C LOAD TYPE CONNECTED NEC CALCULATED POWER DEMAND
LIGHTING 0.0 0.0 0.0 LOAD KVA DEMAND LOAD FACTOR LOAD KW PANEL
RECEPTACLES 0.0 0.0 0.0 CONNECTED PF=
MOTORS 0.0 0.0 0.0 LIGHTING 0.0 KVA x 125% = 0.0 KVA x 95% = 0.0 KW 100%
OTHER 0.0 0.0 0.0 RECEPTACLES
GENERAL 17,268.0 17,268.0 17,268.0 FIRST 10 KVA 0.0 KVA x 100% = 0.0 KVA x 100% = 0.0 KW CONNECTED
TOTAL (VA) 17,268.0 17,268.0 17,268.0 REMAINDER 0.0 KVA x 50% = 0.0 KVA x 100% = 0.0 KW AMPACITY =
MOTORS 143.8
NEC CALCULATED LARGEST 0.0 KVA x 125% = 0.0 KVA x 90% = 0.0 KW
PHASE AMPACITY 143.6 143.6 143.6 REMAINDER 0.0 KVA x 100% = 0.0 KVA x 90% = 0.0 KW NEC DEMAND
OTHER 0.0 KVA x 125% = 0.0 KVA x 100% = 0.0 KW AMPACITY =
225.0 GENERAL 51.8 KVA x 100% = 51.8 KVA x 100% = 51.8 KW 143.8
PHASE BALANCE A-B B-C C-A
0% 0% 0% TOTAL 51.8 KVA 51.8 KVA 51.8 KW
GENERAL NOTES:
' PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT.
' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL.
ISSUE / REVISION:
PROJECT NUMBER
DATE
DRAWN BY
CHECKED BY
NO. DESCRIPTION DATE
475 17th Street, Suite 720 Denver, Colorado 80202 Phone: 720-855-7572 www.iron-horse-architects.com
This document is an instrument of services and as such, remains the property of the Architect.
The use of this document is limited and can be extended only by written agreement with IRON
HORSE ARCHITECTS, INC.
COPYRIGHT 2015 ©
D R e v it L o c a l F ile s \2
\M
E P
-N
IS
T W in g
C u s to m iz a ti o n J H a fe r.
rv t
/3
/2
:3 :5
P
M
ELECTRICAL
PANELBOARD
SCHEDULES
W
IN
G
R E
-C U
S T
O M
IZ
A
T
IO
N
E0.2.1
201009.006
JAH
JAH
03/30/16
B ro a d w a y
B o u ld e r, C O
T TT
FBX
F
P P P P
J
T
TT
P
P P
P P
P P P
J
J
J J
J
J
J J
J
J
J
J
J J
J J
J J
J J
J
J J
J J
J
J
J
J
J
J
J
J
J J J
J
J
JJ
J
J
J
J
P P
F F
J
J J
J JJJ
J J
J
T75 T75
DN
T T T
FBX
J
J
P P
J
PP P P
P
P
PP P
P
J
J J
J
J J
J
J
J
J
J
J J
J
J
J
J
J
J
J
J
J
J
J J
J J
J
J
J
J
J
J J
J
JJ J
J
J
J
J
J
J
J
J
J J J
J
J
F
JJJJ
J
F
J J
J
J
J
J
T
J
T75 T75
M
M
H3LS-A1
H3EQ-B1
H3SB-A2
H3SB-B1
H3SB-A1
L3C-B1
L3LS-A1
L3SB-B1
L3C-A2 L3C-A1
L3-B2
L3C-B1- 41
L3-B2- 3 L3-B2- 3
L3-B2- 3
L3C-B1- 42 L3-B2- 5
L3-B2- 5
L3C-B1- 41
L3-B2- 5
L3-B2- 5
L3-B2- 5
L3-B2- 6
L3-B2- 6
L3-B2- 5
L3C-B1- 39
L3C-B1- 40
L3-B2- 6
L3-B2- 6
L3-B2- 6 L3-B2- 7
L3-B2- 7
L3C-B1- 37 L3C-B1- 37
L3C-B1- 35L3C-B1- 35
L3C-B1- 38 L3C-B1- 38
L3-B2- 7
L3-B2- 7
L3-B2- 8
L3-B2- 7
L3-B2- 7
L3-B2- 8
L3-B2- 8
L3-B2- 8
L3C-B1- 33
L3C-B1- 33
L3C-B1- 31
L3C-B1- 27
L3C-B1- 29
L3C-B1- 36
L3C-B1- 3L3C-B1- 3
L3C-B1- 16 L3C-B1- 16
L3C-B1- 2
L3-B2- 32L3-B2- 30L3-B2- 30
L3-B2- 12 L3-B2- 12
L3-B2- 12
L3-B2- 18 L3-B2- 18
L3-B2- 20
L3-B2- 20
L3-B2- 20
L3-B2- 18
L3-B2- 26
L3-B2- 30
L3-B2- 22
L3-B2- 22
L3-B2- 29L3-B2- 29L3-B2- 29
L3C-B1- 12 L3C-B1- 12
L3C-B1- 11
L3C-B1- 7
L3C-B1- 7
L3C-B1- 7
L3C-A2- 31…