Amendment_Room_Requirements_Sheet_house_keeping.pdf

PDF 80 KB Posted

Attached to
IDIQ MACC FOR LARGE CONSTRUCTION PROJECTS, HAMPTON ROADS, VIRGINIA NAVFAC MID-ATLANTIC Federal contract opportunity
Solicitation number
N4008518R1104
Issued by
Department of the Navy Naval Facilities Engineering Command

About this file

This document provides details for an Indefinite Delivery Indefinite Quantity Multiple Award Construction Contract opportunity with the Department of the Navy Naval Facilities Engineering Command. The solicitation seeks proposals for large general building construction projects ranging from $14 million to $37 million, though smaller or larger projects may be considered. The total estimated value of contracts awarded is $249 million over five years. Five contracts will be awarded. The initial task order involves design-build construction of a 127-room, 78,727 square foot Bachelor Enlisted Quarters facility at Naval Weapons Station Yorktown, Virginia with an estimated cost between $25 million and $100 million. Offerors must submit a bid guarantee of at least 20% of the largest potential award up to $3 million. The request for proposals will be issued on December 15, 2017 with NAICS code 236220 and a competition set-aside as full and open. The primary point of contact is Vivienne Moore.

Amendment_Room_Requirements_Sheet_house_keeping.pdf

View the file

Other files for this federal contract opportunity

Other files attached to IDIQ MACC FOR LARGE CONSTRUCTION PROJECTS, HAMPTON ROADS, VIRGINIA NAVFAC MID-ATLANTIC, newest first.
File Type Posted
AMENDMENT_0021.pdf PDF
AMENDMENT_0020.pdf PDF
AMENDMENT_0019.pdf PDF
ATTACH_19A_P995_Price_Proposal_Form_rev_12JUL18.pdf PDF
ATTACH_19C_Spec_section_01_91_00.15_Total_Bldg_Commissioning.pdf PDF
ATTACH_19B_Revised_spec_sec_01_20_00.00_Price_and_Pymt_Proc.pdf PDF
AMENDMENT_0018.pdf PDF
AMENDMENT_0017.pdf PDF
Amendment_0016.pdf PDF
AMENDMENT_0015.pdf PDF
SECNAV_F0RM_5512-1.pdf PDF
AMENDMENT_0014.docx.pdf PDF
Amendment_Room_Requirement_Sheet_multi-media_room.pdf PDF
building_requirements_RLJ_RGG.pdf PDF
Amendment_0013.pdf PDF
PPI_201_VA_Radon_Map.pdf PDF
AMENDMENT_0012.pdf PDF
Performance-Rating-Method-Compliance-Form-2013.pdf PDF
AMENDMENT_0011_.docx.pdf PDF
Amendment_0010.pdf PDF
P-984-SITE_ELECTRICAL-ES601.pdf PDF
P-985-SITE_ELECTRICAL-ES601.pdf PDF
AMENDMENT_0009.pdf PDF
P-984-SITE_ELECTRICAL-ES604.pdf PDF
Amendment_0008.pdf PDF
Amendment_0007.pdf PDF
P-995_SITE_VISIT_ATTENDEESlist_.pdf PDF
Amendment_0006.pdf PDF
AMENDMENT_0005.pdf PDF
AMENDMENT_0004.pdf PDF
AMENDMENT_0003.pdf PDF
2018_1380460_P-995_DB_MCSFRBEQ_Part_1_and_2.pdf PDF
2018_1380460_P-995_DB_MCSFRBEQ_Part_4.pdf PDF
2018_1380460_P-995_DB_MCSFRBEQ_Part_3.pdf PDF
AMENDMENT_0002.pdf PDF
AMENDMENT_0001.pdf PDF
Attachment_B_-_Past_Performance_Questionnaire.docx DOCX document
Attachment_C_-_Small_Business_Subcontracting_Record.docx DOCX document
18R1104_SOLICITATION.pdf PDF
Attachment_A_-_Construction_and_Design_Experience_Project_Data_Sheet.docx DOCX document
Show all 40

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P-991 MCSFR Bachelor Enlisted Quarters 1312140 Naval Weapons Station, Yorktown, Virginia

PART 3 – CHAPTER 5

HOUSEKEEPING ROOM

Space Characteristics

Function/adjacencies: Storage space on each floor

Special Dimensions: As required, coordinate with user.

Acoustics:

Access: Accessed from central interior corridor.

Number of Occupants: unoccupied

Other/Special Requirements:

Uniformat Section

Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Concrete or Concrete Masonry Unit.

C102001 Interior Doors

A/R 3’x7’ Solid core wood door factory stained and steel frames shall be factory primed and field painted

C102007 Interior Door Hardware

A/R Provide kick plate. Comply with housekeeping keying/access requirements.

C103004 Identifying Devices A/R Provide room signage as required

C302009 Flooring System

SF

Decorative Quartz Epoxy Coating – Seamless, impervious skid resistant finish. ADA compliant transitions are required at all entrances. 2 color

C302007 Wall Base Finishes LF 4” high Integral cove w/ metal cap epoxy base.

C303002 Gypsum Wallboard Ceiling

Finishes SF Painted Ceilings. Paint suitable in accordance with Master Painter Institute (MPI)standards for interior architectural surfaces.

C304001 Interior Painting

SF

Painted Finishes to Concrete or Block Wall Surfaces. HIGH PERFORMANCE ARCHITECTURAL LATEX (over latex block filler)Semi-Gloss Paint

D203003 Floor Drain A/R Provide trap primers.

D30 HVAC A/R

Provide pre-conditioned outside air, return air, exhaust air and supply air for each space/room.

D304001 Air Distribution, Heating, &

Cooling A/R

Outside air and exhaust - Provide CO2 demand controlled ventilation - ASHRAE 62.1 or minimum of 50 cfm whichever is the greater.

D304001 Air Distribution, Heating, &

Cooling A/R

VAV series Fan Powered Units - Provide with Reheat, provide a min of 4 air changes per hour.

D304007 Exhaust Systems A/R Provide exhaust for outside air ventilation.

D304008 Air Handling Unit A/R HVAC Systems - Provide pre-conditioned outside air, return, exhaust, and VAV supply.

D309090 Other Mechanical Systems A/R HVAC System - Recover energy from exhaust air with Total Enthalpy Heat Wheel.

D5020 Lighting Equipment A/R .Fluorescent wraparound surface mounted light fixtures.