E-103_AMEND 4.pdf

PDF 965 KB Posted

Attached to
N4008023R0020 LARGE PROJECTS MULTIPLE AWARD CONSTRUCTION CONTRACT (MACC) Federal contract opportunity
Solicitation number
N4008023R0020
Issued by
Department of the Navy Naval Facilities Engineering Command

About this file

This document contains an electrical site plan and notes for a federal construction project. Key details include that the site plan is for Area 3 at Joint Base Andrews Naval Air Facility Camp Springs, Maryland and shows the locations of proposed airfield lighting fixtures, card readers, transformers, manholes, duct banks, and high mast and obstruction lights to support the relocation of a hazardous cargo pad and EOD proficiency range. Construction notes specify fixture spacing and placement requirements. The related federal contract opportunity is a multiple award construction contract for large projects under solicitation number N40080-23-R-0020 issued by the Department of the Navy Naval Facilities Engineering Command. Offerors should refer to SAM.gov for all solicitation documents and amendments.

View the file

Other files for this federal contract opportunity

Other files attached to N4008023R0020 LARGE PROJECTS MULTIPLE AWARD CONSTRUCTION CONTRACT (MACC), newest first.
File Type Posted
N4008023R0020 Amendment 0010.pdf PDF
N4008023R0020 Amendment 0008.pdf PDF
GI-113_Amend 6.pdf PDF
CS-503_Amend 6 (2).pdf PDF
CU-202_Amend 6 (2).pdf PDF
CU-204_Amend 6 (2).pdf PDF
Additional Site Photos (2).pdf PDF
01 50 00_Amend 6 (2).pdf PDF
GC-005_Amend 6.pdf PDF
GI-112_Amend 6.pdf PDF
CG-122_Amend 6 (2).pdf PDF
CD-102_Amend 6 (2).pdf PDF
CT-502_Amend 6 (2).pdf PDF
32 92 19_Amend 6 (2).pdf PDF
21-SF-0064_Mod 2 stamped plans_P-3002_ESC_Stage_0 Amend 5.pdf PDF
CG-122_Amend 5.pdf PDF
Flashing Beacon Specification and Details Amend 5.pdf PDF
Site Visit Seed Project Photos (P-3002 HCL).pdf PDF
N4008023R0020 Amendment 0005.pdf PDF
P-3002 HCP Price Schedule_BLANK 4-5-23 AMEND 4.pdf PDF
CG-102A_AMEND 4.pdf PDF
CS-102_REV_AMEND 4.pdf PDF
GI-115_AMEND 4.pdf PDF
CT-501 AMEND 4.pdf PDF
Additional Information on Batch Plant Site AMEND 4.pdf PDF
33 10 00 Water Piping Structures and Appurtenances_AMEND 4.pdf PDF
MDE 18-SF-0054 JADOC BORROW PITS SIGNED DWGS_3 of 3 AMEND 4.pdf PDF
S-600_Rev AMEND 4.pdf PDF
Site Visit Details.pdf PDF
Wage D Heavy Prince Georges 3-24-23 AMEND 4.pdf PDF
CP-103_AMEND 4.pdf PDF
CT-102_AMEND 4.pdf PDF
Attachment F - SBPCD.docx DOCX document
GI-102_REV.pdf PDF
Attachment P-3002 Price Proposal Form 3-22-23.pdf PDF
N4008023R0020 Amendment 0002.pdf PDF
P-3002 IFC PLANS_REV_signed_Part 3 of 7.pdf PDF
Attachment H - Base Access Form 4973-16FEB2023.xlsx XLSX spreadsheet
P-3002 IFC PLANS_REV_signed_Part 2 of 7.pdf PDF
P-3002 IFC PLANS_REV_signed_Part 1 of 7.pdf PDF
2022.09.26 P-3002 IFC PLANS_N4008023R0020 INSTRUCTIONS.docx DOCX document
Attachment C - CONSTRUCTION DESIGN EXPERIENCE PROJECT DATA SHEET.docx DOCX document
N40080-23-R-0020 LARGE PROJECTS MACC.pdf PDF
Attachment A- PIEE Vendor Access Instructions.pdf PDF
P-3002 HCP Price Schedule_BLANK 3-1-23.pdf PDF
Attachment D - PPQ.docx DOCX document
2022.09.26 P-3002 IFC Specifications_signed_N40080-23-R-0020.pdf PDF
Attachment F - SBPCD.docx DOCX document
Attachment B - PPI Log.xlsx XLSX spreadsheet
Attachment E - Historical Utilization of SB.docx DOCX document
Show all 50

N4008023R0020 LARGE PROJECTS MULTIPLE AWARD CONSTRUCTION CONTRACT (MACC) has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

2 1

6 7

MHMH

MH

MH

12 13

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G C

O M

M

AN

D

DRAWFORM REVISION: 06 APRIL 2017

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

W A

S H

IN

G

TO

N

JO

IN

T

BA

SE

A

N D

R

EW

S N

AV

AL

A

IR

F

AC

IL

IT

Y C

AM

P

SP

R

IN

G

S, M

D

POJCH JCH

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

P -3

R E

LO

C

A

TE

H A

ZA

R

D O

U S

C A

R G

O P

A D

A N

D E

O D

P R

O

FI

C

IE

N C

Y R

A N

G E

W

AS

H

IN

G

TO

N N

AV

Y

YA

R

D W

AS

H

IN

G

TO

N

, D C

N40080-15-D-0452

1396650

KEY PLAN

IS

SU

E

FO

R

CO

NS

TR

UC

TI

ON

9/2 6/2

E

LE

C

TR

IC

A

L S

IT

E

P

LA

N

A R

E A

E-103

M

AT

CH

L

IN

E

- S

EE

S

HE

ET

E

-1

1" = 50'A1 ELECTRICAL SITE PLAN - AREA 3

PLAN

NORTH

GENERAL NOTES

1. ALL EXISTING UNDERGROUND UTILITY LOCATIONS AS SHOWN ON

THESE PLANS ARE APPROXIMATE AND MAY NOT REPRESENT ALL

UNDERGROUND UTILITIES OR SERVICE LINES. SOURCE OF EXISTING

UTILITY MAPPING: UTILITY LOCATIONS ARE BASED ON QUALITY LEVEL

"B" AS DEFINED BY ASCE STANDARD 38-02 "STANDARD GUIDELINE FOR

THE COLLECTION AND DEPICTION OF EXISTING SUBSURFACE UTILITY

DATA". VERIFY EXACT LOCATION, DEPTH, SIZE, AND TYPE OF UTILITIES

SHOWN AND NOTIFYING ENGINEER OF DISCREPANCIES. REPAIR AND

REPATCH AS NEEDED SUBSEQUENT ANY DAMAGE SUSTAINED TO

PROPERTY OR UTILITIES.

2. CONTACT "MARYLAND MISS UTILITY" AT 1-800-257-7777 PRIOR TO

BEGINNING ANY EXCAVATION OR DEMOLITION.

3. SEE SHEET E-501 FOR SITE LIGHTING FIXTURE SCHEDULE.

4. SEE SHEET E-104 FOR CABLE SCHEDULE.

5. COORDINATE SITE LIGHTING POLE BASE EXACT LOCATION WITH THE

LANDSCAPING DESIGN.

6. SEE SHEET E-104 FOR NHCP PANEL SCHEDULE.

WORK NOTES

1. PROVIDE AIRFIELD LIGHTING FIXTURES. AIRFIELD LIGHTING FIXTURES

ARE LOCATED AT A DISTANCE NO GREATER THAN 200' FROM EACH

OTHER AT STRAIGHT TAXIWAY SECTIONS. AIRFIELD LIGHTING FIXTURES

LOCATED 10' FROM EDGE OF CONCRETE TAXIWAY.

2. PROVIDE AN ADDITIONAL SINGULAR AIRFIELD LIGHTING FIXTURE IS

PLACED 40' FROM END OF STRAIGHT TAXIWAY SECTIONS.

3. PROVIDE AIRFIELD LIGHTING FIXTURES AT CURVED TAXIWAY SECTIONS.

PLACE FIXTURES A MINIMUM OF THREE (3) PER CURVED AREAS THAT

ARE GREATER THAN 30 DEGREES.

4. PROVIDE CARD READER PER DETAIL A1/E-501 12" OFF FINISHED CURB.

5. PROVIDE 45KVA, 13200GY/7200V-208V/120, 3Ø, PAD MOUNTED

TRANSFORMER.

6. PROVIDE MANHOLE PER SPECIFICATION. SEE DETAIL C3, SHEET E-503.

7. PROVIDE 2-WAY, 2X1, 5"C, CONCRETE ENCASED DUCT BANK.

8. SEE DETAIL A1, SHEET E-504.

9. PROVIDE NEMA 3R C-CHANNEL POWER AND CONTROL RACK, SERVICE

DISCONNECT, MANUAL TRANSFER SWITCH WITH GENERATOR

CONNECTION AND NEMA 4X 100A PANEL BOARD. SEE ELEVATION AND

RISER ON SHEET E-502.

10. NOT USED.

11. NOT USED.

12. PROVIDE HIGH MAST APRON LIGHTS. SEE DETAIL A5 ON SHEET E-502.

TYPICAL.

13. PROVIDE OBSTRUCTION LIGHTS ON TOP OF POLE. SEE DETAIL A5 ON

SHEET E-502. TYPICAL.

M

AT

CH

L

IN

E

- S

EE

S

HE

ET

E

-1

1 2 3 4

/01 /20

AM

EN

DM

EN

T jchiggins Rectangle jchiggins Snapshot jchiggins Cloud jchiggins Snapshot jchiggins Rectangle jchiggins Rectangle jchiggins Rectangle jchiggins Rectangle jchiggins Rectangle jchiggins Rectangle jchiggins Rectangle jchiggins Text Box jchiggins Snapshot jchiggins Snapshot

File details come from the government source that posted it. Updated .