HHS CONCESSIONS - MECH - PERMIT.pdf
PDF 872 KB Posted
- Attached to
- Weber Concession & Bathroom Building
- Solicitation number
- S-P30001-00014684
- Issued by
- Union County, Oregon
About this file
These documents are mechanical and plumbing engineering plans for a new concessions and restrooms project for the Hermiston School District in Hermiston, Oregon, prepared by Energy System Engineers (ESE) in Spokane, Washington. The permit set includes detailed mechanical and plumbing floor plans, specifications, schedules, and installation details for a construction project located at 600 South 1st Street. The plans cover HVAC systems, plumbing fixtures, piping, electrical equipment, and associated infrastructure for the new facility, with drawings dated April 29, 2025 and labeled as a permit set.
The project specifications outline comprehensive requirements for equipment installation, including compliance with local and state building codes such as the 2022 Oregon Structural Specialty Code, 2025 Oregon Energy Efficiency Specialty Code, and 2023 Oregon Plumbing Specialty Code. The mechanical and plumbing systems include specific equipment like electric water heaters, inline ventilators, electric unit heaters, wall heaters, diffusers, grilles, louvers, floor drains, floor sinks, lavatories, water closets, urinals, and a grease interceptor for the concessions area. The plans specify detailed installation methods, support requirements, insulation specifications, seismic restraints, and testing and balancing procedures to ensure proper system performance and code compliance.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTROL VALVE
THREE-WAY CONTROL VALVE
PRESSURE SAFETY RELIEF VALVE
FLEXIBLE CONNECTION
PRESSURE REDUCING/REGULATOR VALVE
PUMP
M##
M##
TAG #
CROSS-SECTION SYMBOL
(TOP=SECTION NUMBER,BOTTOM=SHEET NUMBER)
DETAIL SYMBOL
(TOP=DETAIL NUMBER, BOTTOM=SHEET NUMBER)
POINT OF CONNECTION (POC) SYMBOL
EQUIPMENT IDENTIFIER
(EQUIPMENT TYPE & EQUIPMENT NUMBER)
DIFFUSER OR REGISTER/GRILLE TAG
(FIRST VALUE=SIZE,
SECOND VALUE=GRD TYPE/TAG (SEE SCHEDULES),
THIRD VALUE=CFM)
SIZE
KEY NOTES
REVISION NUMBER
REFRIGERANT SUCTION
REFRIGERANT LIQUID
RS
RL
CONDENSATE DRAINCD
REF REFRIGERANT LINE SET
NG NATURAL GAS
LIGHT DASHED LINES = HIDDEN OR UNDERGROUND
DARK LINE = NEW
SUPPLY DIFFUSER
RETURN GRILLE
EXHAUST GRILLE
ROUND DUCT UP THRU ROOF OR FLOOR
FLEX DUCT
BALANCE DAMPER
MOTORIZED DAMPER
COMBINATION FIRE/SMOKE DAMPER
SMOKE DETECTOR (DUCT MOUNTED)
SUPPLY AIR ELBOW UP
SUPPLY AIR ELBOW DOWN
RETURN AIR ELBOW UP
RETURN AIR ELBOW DOWN
EXHAUST AIR ELBOW UP
EXHAUST AIR ELBOW DOWN
CONCENTRIC TRANSITION
ECCENTRIC TRANSITION
S
THERMOSTAT
AVERAGING THERMOSTAT
HUMIDITY SENSOR
TEMPERATURE SENSOR (DUCT OR PIPE MOUNTED)
PRESSURE SWITCH OR SENSOR
HUMIDITY SENSOR (DUCT MOUNTED)
TEMPERATURE SENSOR
TS
HS
TS
T
A
H
P
SWITCH
VALVE ( SEE PLANS AND SPECIFICATIONS FOR TYPE)
CHECK VALVE
FLOW DIRECTION
INDICATOR
PIPE TEE BRANCH DOWN
(W/ ELBOW)
PIPE ELBOW DOWN
PIPE TEE BRANCH
UP (W/ ELBOW)
PIPE ELBOW UP
HVAC ABBREVIATIONS HVAC SYMBOLS MECHANICAL PIPING SYMBOLS
T
THERMOSTAT W/ CO2 SENSORCT
CO2 SENSORCO2
SMOKE DETECTORSD
FS
MECHANICAL PIPING LEGEND
ACOUSTICALLY-LINED DUCTWORK
GENERAL SYMBOLS
MECHANICAL GENERAL NOTES
COORDINATION NOTES
DUCTWORK NOTES
MECHANICAL PIPING NOTES
LINE WEIGHT LEGEND
DIFFERENTIAL PRESSURE TRANSMITTERDPT
# CFM
M
A. ALL WORK SHALL COMPLY WITH THE OWNERS REQUIREMENTS, AND WITH ALL
APPLICABLE STATE AND LOCAL CODES, OR AUTHORITY HAVING JURISDICTION.
B. DRAWINGS ARE DIAGRAMMATIC IN NATURE AND DO NOT NECESSARILY SHOW EXACT
LOCATIONS OF PIPING AND DUCTWORK. DIAGRAMS ARE SCHEMATIC AND DO NOT
NECESSARILY SHOW THE PHYSICAL ARRANGEMENT OF THE EQUIPMENT. DRAWINGS
SHALL NOT BE USED AS SHOP DRAWINGS FOR PIPING AND DUCTWORK FABRICATION
OR ORDERING. DISCREPANCIES SHOWN ON OR BETWEEN PLANS AND ACTUAL FIELD
CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER
FOR RESOLUTION.
C. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF
A SATISFACTORY AND COMPLETE SYSTEM IN ACCORDANCE WITH THE INTENT OF
THE DRAWINGS AND SPECIFICATIONS. PROVIDE, AT NO ADDITIONAL COST, ALL
ANCILLARY ITEMS, MATERIALS, ACCESSORIES, AND LABOR REQUIRED FOR
COMPLETION OF THE WORK EVEN IF THEY ARE NOT SPECIFICALLY MENTIONED OR
INDICATED ON THE DRAWINGS OR IN THE SPECIFICATIONS.
D. PROVIDE SEISMIC RESTRAINTS FOR ALL PIPING EQUIPMENT, AND DUCTWORK AS
RECOMMENDED IN SMACNA "SEISMIC RESTRAINT MANUAL GUIDELINES FOR
MECHANICAL EQUIPMENT", LATEST EDITION. CONSULT LOCAL SEISMIC CODES FOR
THE SEISMIC RATING OF THE AREA IN WHICH THE PROJECT IS BEING BUILT.
E. SUBSTITUTIONS OF EQUIPMENT OTHER THAN AS SPECIFIED SHALL BE THE
COMPLETE RESPONSIBILITY OF THE CONTRACTOR. ANY ADDITIONAL ELECTRICAL,
STRUCTURAL, MECHANICAL OR ARCHITECTURAL REQUIREMENTS SHALL BE
PROVIDED AT NO ADDITIONAL EXPENSE TO OWNER.
F. THERMOSTATS, TEMPERATURE SENSORS, AND CO2 SENSORS SHALL BE INSTALLED
AT 48" AFF UNLESS NOTED OTHERWISE. COORDINATE FINAL LOCATION WITH THE
OWNER PRIOR TO INSTALL. COORDINATE JUNCTION BOX INSTALLATION WITH
ELECTRICAL CONTRACTOR AS NEEDED.
G. ALL OUTDOOR AIR INTAKES & EXHAUST AIR OUTLETS SHALL BE PROVIDED WITH
CLASS 1 LOW LEAKAGE MOTORIZED DAMPERS (≤ 4 CFM/SF @ 1"WG) UNLESS
OTHERWISEE NOTED. OUTSIDE AIR INTAKES SHALL BE INSTALLED WITH A MINIMUM
SEPARATION OF 10'-0" FROM ALL EXHAUST AIR DISCHARGE, GAS FLUES, AND
PLUMBING VENTS.
H. SEE SPECIFICATIONS FOR FURTHER REQUIREMENTS.
A. COORDINATE INSTALLATION WITH THE WORK OF OTHER TRADES PRIOR TO
STARTING. IN THE EVENT THAT CONFLICTS ARE FOUND WITH THE WORK OF OTHER
TRADES, BRING ALL SUCH CONFLICTS TO THE DESIGN TEAM'S ATTENTION FOR
RESOLUTION PRIOR TO PROCEEDING WITH THE WORK IN THAT AREA.
DEFICIENCIES CAUSED BY FAILURE TO PERFORM SUCH VERIFICATIONS SHALL BE
CORRECTED AT NO ADDITIONAL EXPENSE TO OWNER.
B. THE HVAC CONTRACTOR IS RESPONSIBLE FOR COORDINATING FINAL LOCATIONS
OF DIFFUSERS, REGISTERS AND GRILLES WITH ARCHITECTURAL REFLECTED
CEILING PLANS. CONTRACTOR SHALL NOT DEVIATE FROM REFLECTED CEILING
PLAN UNLESS THERE ARE EXTENUATING JOB SITE CONDITIONS.
C. MECHANICAL DRAWINGS (PLUMBING AND HVAC) ARE SCHEMATIC. PLANS DO NOT
DETAIL ALL TRANSITIONS, OFFSETS, FITTINGS, ETC. THE CONTRACTOR MUST
SUPPLY ALL REQUIRED TRANSITIONS TO PREVENT CONFLICTS WITH OTHER
DUCTWORK, PIPING, STRUCTURE, ETC., UNDER THIS CONTRACT. WHEN FEASIBLE,
OFFSETS SHOULD USE 45-DEGREE ELBOWS WITH TURNING VANES.
D. ROUTE ALL MECHANICAL COMPONENTS CONCEALED WHEN POSSIBLE. ALL
EXPOSED DUCTWORK AND PIPING SHOULD BE COORDINATED WITH OTHER TRADES
AND ROUTED PARALLEL OR PERPENDICULAR TO BUILDING COMPONENTS.
E. PRIOR TO BIDDING, OBTAIN A COPY OF THE SPECIFICATIONS AND PLANS, VISIT THE
JOB SITE, TAKE ALL NECESSARY MEASUREMENTS, NOTE EXISTING CONDITIONS,
AND GATHER ALL OTHER INFORMATION NEEDED FOR AN ACCURATE BID.
ALLOWANCES WILL NOT BE MADE FOR EXTRA COSTS RESULTING FROM FAILURE
TO NOTE EXISTING CONDITIONS.
F. FIELD COORDINATE ALL PENETRATIONS AND ADJUST TO AVOID WITH CONFLICT OF
OTHER TRADES ESPECIALLY STRUCTURAL COMPONENTS. DIV 22,23 CONTRACTOR
IS RESPONSIBLE FOR ALL SAW CUTTING FOR MECHANICAL SYSTEM.
A. FOR LOW PRESSURE DUCTWORK, WHERE RECTANGULAR DUCT IS INDICATED ON
PLANS, EQUIVALENT SIZE ROUND DUCT MAY BE USED. EQUIVALENT SIZE
RECTANGULAR DUCT MAY BE USED IN PLACE OF ROUND DUCT, EXCEPT IN EXPOSED
AREAS. EQUIVALENT RECTANGULAR SIZE MAY NOT BE USED ON DUCTS EXPOSED TO
VIEW OR AS INDICATED OTHERWISE.
B. THE DIMENSIONS OF DUCTWORK INDICATED ON THE DRAWINGS REPRESENT
OUTSIDE MEASUREMENTS. THE HVAC CONTRACTOR IS RESPONSIBLE FOR
ADJUSTING FOR EXTERIOR INSULATION AS NECESSARY.
C. PROVIDE ACCESS DOORS IN DUCTWORK FOR RESETTING OF FIRE/SMOKE DAMPERS
WHERE INDICATED AND AS REQUIRED BY SPECIFICATIONS OR CODE. INSTALL FIRE
DAMPERS OR FIRE-SMOKE DAMPERS AT ALL DUCT PENETRATIONS IN RATED WALLS
AS MANDATED BY THE RELEVANT BUILDING CODE.
D. VOLUME DAMPERS ARE NOT INDICATED ON DRAWINGS. PROVIDE VOLUME DAMPERS
ON EACH BRANCH DUCT PRIOR TO THE RGD.
E. ALL ELBOWS ARE STANDARD RADIUS (R=3W/2) UNLESS NOTED OTHERWISE. DO NOT
SUBSTITUTE MITERED ELBOWS FOR RADIUS ELBOWS UNLESS APPROVED IN
WRITING BY THE ENGINEER OF RECORD. PROVIDE TURNING VANES ON ALL
RECTANGULAR DUCT ELBOWS WHETHER SHOWN OR NOT.
F. PROVIDE TRANSITIONS AS NEEDED FOR CONNECTION TO EQUIPMENT. PROVIDE
FLEXIBLE CONNECTIONS TO ALL EQUIPMENT WITH FANS OR AS INDICATED ON
DRAWINGS AND DETAILS.
G. DO NOT PINCH OR KINK FLEX DUCT. FLEX DUCT DIAMETER SHOULD BE MAINTAINED
WITHOUT WARPING. MAXIMUM FLEX DUCT LENGTH SHALL BE APPROXIMATELY 6'.
ONLY USE FLEX DUCT AS SHOWN ON PLANS OR DETAILS.
A. PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE FIRESTOPPED IN
ACCORDANCE WITH THE ADOPTED YEAR OF THE IBC SECTION 713.
B. PROVIDE PIPE TRANSITIONS AS NEEDED WHEN CONNECTING TO EQUIPMENT. OFTEN
EQUIPMENT SIZE CONNECTIONS WILL DIFFER FROM PIPE SIZE. TRANSITION IS TO
HAPPEN DIRECTLY AT UNIT; PIPE SIZE AND COMPONENTS ARE TO BE FULL SIZE AS
SHOWN ON PLANS.
C. REFER TO DETAILS AND DIAGRAMS FOR PIPING COMPONENTS. PLAN VIEW DRAWINGS
WILL NOT INDICATE ALL REQUIRED PIPING COMPONENTS. PROVIDE ALL COMPONENTS
NEEDED FOR A COMPLETE INSTALL.
(D) DEMOLISH
(E) EXISTING
(N) NEW
ABS ACRYLONITRILE BUTADIENE
STYRENE
AC AIR CONDITIONING
ACCU AIR COOLED CONDENSING UNIT
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHU AIR HANDLING UNIT
AL ALUMINUM
APD AIR PRESSURE DROP
APPROX APPROXIMATE
ARCH ARCHITECT, ARCHITECTURAL
ASHRAE AMERICAN SOCIETY OF HEATING,
REFRIGERATION, AND AIR
CONDITIONING ENGINEERS
AUTO AUTOMATIC
BD BAROMETRIC DAMPER
BDD BACK DRAFT DAMPER
BHP BRAKE HORSE POWER
BLDG BUILDING
BOD BOTTOM OF DUCT
BOT BOTTOM
BTU BRITISH THERMAL UNIT
C COMMON
C/W COORDINATE WITH
CAB CABINET
CFM CUBIC FEET PER MINUTE
CL CENTERLINE
CLG CEILING
CONC CONCRETE
D DEPTH, DEEP
DB DRY BULB TEMPERATURE
DDC DIRECT DIGITAL CONTROL
DIA/Ø DIAMETER
DIFF DIFFUSER
DN DOWN
DS DEW POINT SENSOR
DUC DOOR UNDER CUT
DWG DRAWING
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EER ENERGY EFFICIENCY RATIO
EF EXHAUST FAN
EFF EFFICIENCY
EG EXHAUST GRILLE
EL ELEVATION
ELEC ELECTRIC, ELECTRICAL
ELEV ELEVATOR
EQUIP EQUIPMENT
ESP EXTERNAL STATIC PRESSURE
EXH EXHAUST
EXT EXTERIOR
F FAHRENHEIT
FCU FAN COIL UNIT
FD FIRE DAMPER
FLA FULL LOAD AMPS
FP FIRE PROTECTION
FPM FEET PER MINUTE
FSD COMBINATION FIRE/SMOKE DAMPER
FT FEET
FT HD FEET OF HEAD
FUR FURNACE
G GAS
GA GAUGE
GAL GALLON
GALV GALVANIZED
GC GENERAL CONTRACTOR
GPM GALLONS PER MINUTE
HP HORSEPOWER
HS HUMIDITY SENSOR
HT HEIGHT/HIGH
HTR HEATER
HVAC HEATING/VENTILATION, AIR
CONDITIONING
HW HOT WATER (DOMESTIC)
HX HEAT EXCHANGER
IBC INTERNATIONAL BUILDING CODE
ID INSIDE DIAMETER
IE INVERT ELEVATION
IECC INTERNATIONAL ENERGY
CONSERVATION CODE
IFGC INTERNATIONAL FUEL GAS CODE
IMC INTERNATIONAL MECHANICAL CODE
IN WC INCHES OF WATER COLUMN
INSUL INSULATION, INSULATE
KW KILOWATT
LAT LEAVING AIR TEMPERATURE
LBS POUNDS
LVR LOUVER
MA MILLIAMPS
MAX MAXIMUM
MCA MINIMUM CIRCUIT AMPACITY
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MOCP MAXIMUM OVER CURRENT
PROTECTION
MTD MOUNTED
MUA MAKE UP AIR UNIT
N NEUTRAL
NC NORMALLY CLOSED
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NO/# NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OBD OPPOSED BLADE DAMPER
OC ON CENTER
OD OUTSIDE DIAMETER
OEESC OREGON ENERGY EFFICIENCY
SPECIALTY CODE
OPNG OPENING
OSA OUTSIDE AIR
PH PREHEAT
PREFAB PREFABRICATED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PVC POLYVINYL CHLORIDE
R/RAD RADIUS
RA RETURN AIR
RE: REFERENCE
REF REFRIGERANT
REQ'D REQUIRED
RG RETURN AIR GRILLE
RGD REGISTERS, GRILLES, AND
DIFFUSERS
RM ROOM
RPM REVOLUTIONS PER MINUTE
RL REFRIGERANT LIQUID
RS REFRIGERANT SUCTION
RTU ROOFTOP UNIT
SA SUPPLY AIR
SCHED SCHEDULE
SD SMOKE DETECTOR
SEER SEASONAL ENERGY EFFICIENCY
RATIO
SAT SUPPLY AIR TEMPERATURE
SHT SHEET
SP STATIC PRESSURE
SPEC(S) SPECIFICATION(S)
SQ. FT. SQUARE FEET
STD STANDARD
TD TEMPERATURE DIFFERENCE
TEMP TEMPERATURE
TS TEMPERATURE SENSOR
TXV THERMAL EXPANSION VALVE
TYP TYPICAL
UH UNIT HEATER
UV UNIT VENTILATOR
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER
VEL VELOCITY
VFD VARIABLE FREQUENCY DRIVE
VIF VERIFY IN FIELD
VVF VARIABLE VOLUME-FAN POWERED
VVR VARIABLE VOLUME-REHEAT
W WIDE, WIDTH
W/ WITH
W/O WITHOUT
WB WET BULB TEMPERATURE
WC WATER COLUMN
WSEC WASHINGTON STATE ENERGY CODE
OEESC NOTES
A. LOAD CALCULATIONS HAVE BEEN PERFORMED IN ACCORDANCE WITH C403.1.2 AND
ARE AVAILABLE TO PLAN REVIEWER UPON REQUEST.
B. PROVIDE RECORD DRAWINGS TO THE BUILDING OWNER OR THEIR AUTHORIZED
AGENT WITHIN 90 DAYS OF THE DATE OF RECEIPT OF THE CERTIFICATE OF
OCCUPANCY.
C. PROVIDE OPERATIONS & MAINTENANCE MANUALS FOR ALL COMPONENTS &
EQUIPMENT.
D. PROVIDE SYSTEMS OPERATION TRAINING.
E. TAB SHALL BE PROVIDED.
SPOKANE, WA
WWW.ES-ENG.COM
Project number
Date
Drawn by
Checked by
SHEET TITLE:
M0.1
LEGENDS,
ABBREVIATIONS, &
NOTES
25.10
N E W
C O
N C E S S
IO
N S
R E S T R O
O M
S
PERMIT SET
04/29/25
LJH
LJG
H E R M
IS
T O
N S
C H
O O
L D
IS
T R
IC
T
S
O U
T H
S T S
T R E E T
H E R M
IS
T O
N
O R E G
O N
K N
E R R C
O N
S T R U
C T
IO
N
IN
C
REV # DESCRIPTION DATE
MECHANICAL SPECIFICATIONS
PART 1 - GENERAL
1. SUBMITTALS
A. PROVIDE PRODUCT DATA SUBMITTALS FOR EACH TYPE OF EQUIPMENT AND PRODUCT PROVIDED FOR THIS PROJECT.
B. PROVIDE CERTIFICATES AS REQUIRED FOR TRADES REQUIRED TO COMPLETE THIS PROJECT.
2. QUALITY ASSURANCE
A. PROVIDE MANUFACTURERS STANDARD WARRANTY ON ALL EQUIPMENT WHERE MANUFACTURER AGREE TO REPAIR OR
REPLACE COMPONENTS THAT FAIL IN MATERIAL OR WORKMANSHIP WITHIN SPECIFIED WARRANTY PERIOD.
B. EQUIPMENT IS TO BE SAFELY STORED SUCH THAT EQUIPMENT IS CLEAN AND FREE OF DEBRIS AND PROTECTED FROM
THEFT AND OTHER DAMAGE.
3. COMPLIANCE
A. INSTALL AND WORKMANSHIP SHALL COMPLY WITH ALL LOCAL CODES AND REQUIREMENTS. THIS INCLUDES BUT IS NOT LIMITED TO THE 2022 OREGON STRUCTURAL SPECIALTY CODE, 2025 OREGON ENERGY EFFICIENCY SPECIALTY CODE, 2023 OREGON PLUMBING SPECIALTY CODE, 2022 OREGON MECHANICAL SPECIALTY CODE, ASHRAE, NATIONAL
ELECTRICAL CODE, ETC.
4. COORDINATION
A. COORDINATE WITH ALL OTHER TRADES BEFORE FINAL INSTALL.
B. COORDINATE WITH ELECTRICAL CONTRACTOR FOR PROPER CLEARANCE, DISCONNECTS, POWER, ETC.
C. COORDINATE SIZE AND LOCATION OF ALL BUILDING PENETRATIONS REQUIRED FOR INSTALLATION D. COORDINATE SEQUENCING OF CONSTRUCTION FOR ASSOCIATED PLUMBING, HVAC, ELECTRICAL SUPPLY.
5. CLOSE OUT
A. PROVIDE OPERATIONS AND MAINTENANCE DATA MANUAL IN ELECTRONIC PDF FORM TO THE OWNER AFTER PROJECT
COMPLETION.
a. O&M MANUAL SHALL INCLUDE PRODUCT DATA AND PERFORMANCE DATA FOR EACH PIECE OF EQUIPMENT AND
PRODUCT.
b. O&M MANUAL SHALL INCLUDE A TABLE OF CONTENTS.
6. SEISMIC DESIGN
A. PROVIDE SEISMIC RESTRAINTS AS REQUIRED BY THE CLASS, OCCUPANCY CATEGORY, AND SPECTRAL RESPONSE.
B. SHOULD SEISMIC DEVICES BE REQUIRED, THIS DESIGN SHALL BE DELEGATED TO A QUALIFIED SEISMIC DESIGN
PROFESSIONAL.
7. TESTING, ADJUSTING, AND BALANCING (TAB)
A. PROVIDE CERTIFIED TAB REPORT AFTER COMPLETION OF PROJECT.
PART 2 - PRODUCTS
1. VIBRATION ISOLATION
A. MANUFACTURERS: AMBER/BOOTH CO, B-LINE, KINETICS NOISE CONTROL, MASON INDUSTRIES, VIBRO-ACOUSTICS.
B. PROVIDE ELASTOMERIC PADS, ELASTOMERIC MOUNTS, ELASTOMERIC HANGERS, SPRING HANGERS, SPRING
ISOLATORS, AND SPRING ISOLATION ROOF CURBS AS INDICATED IN PART 3 OR AS INDICATED ON PLANS AND
SCHEDULES.
C. SIZE AND TYPE SHALL BE RATED FOR THE EQUIPMENT SUPPLIED.
2. INSULATION
A. MANUFACTURERS: ARMACELL, JOHNS MANVILLE, KNAUF, OWENS CORNING
B. FLEXIBLE ELASTOMERIC: CLOSED-CELL OR EXPANDED-RUBBER MATERIALS; SUITABLE FOR MAXIMUM USE
TEMPERATURE BETWEEN MINUS 70 DEG F (MINUS 57 DEG C) AND 220 DEG F (104 DEG C). COMPLY WITH ASTM C534, TYPE II FOR SHEET MATERIALS.
C. GLASS-FIBER BLANKET: GLASS FIBERS BONDED WITH A THERMOSETTING RESIN; SUITABLE FOR MAXIMUM USE TEMPERATURE UP TO 450 DEG F (232 DEG C) IN ACCORDANCE WITH ASTM C411. COMPLY WITH ASTM C553, TYPE II, AND ASTM C1290, FACTORY-APPLIED JACKET REQUIREMENTS ARE SPECIFIED IN "FACTORY-APPLIED JACKETS" ARTICLE.
D. GLASS-FIBER BOARD INSULATION: GLASS FIBERS BONDED WITH A THERMOSETTING RESIN; SUITABLE FOR MAXIMUM USE TEMPERATURE BETWEEN 35 DEG F (1.7 DEG C) AND 250 DEG F (121 DEG C) FOR JACKETED AND BETWEEN 35 DEG F (1.7 DEG C) AND 450 DEG F (232 DEG C) FOR UNFACED IN ACCORDANCE WITH ASTM C411. COMPLY WITH ASTM C612, TYPE IA OR TYPE IB. FOR DUCT AND PLENUM APPLICATIONS, PROVIDE INSULATION FSK JACKET. FACTORY-APPLIED JACKET
REQUIREMENTS ARE SPECIFIED IN "FACTORY-APPLIED JACKETS" ARTICLE.
E. GLASS-FIBER, PIPE AND TANK: GLASS FIBERS BONDED WITH A THERMOSETTING RESIN; SUITABLE FOR MAXIMUM USE TEMPERATURE BETWEEN 35 DEG F (1.7 DEG C) AND 850 DEG F (454 DEG C), IN ACCORDANCE WITH ASTM C411. COMPLY
WITH ASTM C1393.
a. SEMIRIGID BOARD MATERIAL WITH FACTORY-APPLIED ASJ JACKET.
F. ADHESIVES, MASTICS, COATINGS: MATERIAL SHALL BE COMPATIBLE WITH INSULATION MATERIAL G. TAPES: ASJ TAPE: WHITE VAPOR-RETARDER TAPE MATCHING FACTORY-APPLIED JACKET WITH ACRYLIC ADHESIVE, COMPLYING WITH ASTM C1136. FSK TAPE: FOIL-FACE, VAPOR-RETARDER TAPE MATCHING FACTORY-APPLIED JACKET
WITH ACRYLIC ADHESIVE; COMPLYING WITH ASTM C1136.
3. DUCTWORK
A. GENERAL FABRICATION REQUIREMENTS: COMPLY WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL
AND FLEXIBLE" BASED ON INDICATED STATIC-PRESSURE CLASS UNLESS OTHERWISE INDICATED. DUCTWORK SHALL BE
CONSTRUCTED AND ERECTED IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE.
B. CONSTRUCTION OF DUCTS SHALL BE GALVANIZED SHEET STEEL UNLESS OTHERWISE INDICATED. COMPLY WITH
ASTM A653/A653M.
C. ROUND DUCT: ROUND DUCT SHALL BE SPIRAL LOCK SEAM. LONGITUDINAL SEAM ROUND DUCTWORK IS NOT ACCEPTABLE. FITTINGS SHALL BE IN ACCORDANCE WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE," FIGURE 3-5, "90 DEGREE TEES AND LATERALS," AND FIGURE 3-6, "CONICAL TEES," FOR STATIC-PRESSURE CLASS, APPLICABLE SEALING REQUIREMENTS, MATERIALS INVOLVED, DUCT-SUPPORT INTERVALS, AND OTHER
PROVISIONS IN SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE.".
D. RECTANGULAR DUCT: ELBOWS, TRANSITIONS, OFFSETS, BRANCH CONNECTIONS, AND OTHER DUCT CONSTRUCTION:
SELECT TYPES AND FABRICATE IN ACCORDANCE WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE," CH. 4, "FITTINGS AND OTHER CONSTRUCTION," FOR STATIC-PRESSURE CLASS, APPLICABLE SEALING REQUIREMENTS, MATERIALS INVOLVED, DUCT-SUPPORT INTERVALS, AND OTHER PROVISIONS IN SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE." ROUND BRANCH DUCTWORK SHALL USE SPIN IN FITTINGS UNLESS
OTHERWISE INDICATED.
E. PRESSURE DUCT SYSTEM CLASS B: THIS SHALL BE CONSIDERED ALL SUPPLY, RETURN, AND EXHAUST DUCTS ON THIS
PROJECT UNLESS OTHERWISE INDICATED.
F. SEALANT SHALL BE WATER-BASED JOINT AND SEAM SEALANT. APPLICATION METHOD: BRUSH ON. SOLIDS CONTENT:
MINIMUM 65 PERCENT. SHORE A HARDNESS: MINIMUM 20. WATER RESISTANT. MOLD AND MILDEW RESISTANT. VOC:
MAXIMUM 75 G/L (LESS WATER).
G. FIBROUS-GLASS DUCT LINER: COMPLY WITH ASTM C1071, NFPA 90A, OR NFPA 90B; AND WITH NAIMA AH124, "FIBROUS
GLASS DUCT LINER STANDARD." PRODUCT SHALL BE ANTIMICROBIAL EROSION-RESISTANT.
a. INSTALL 1" DUCT LINER WHERE INDICATED ON PLANS.
H. DRYER EXHAUST DUCT: FULLY SEALED ALUMINUM OR STAINLESS-STEEL DUCTWORK OF 24-GAUGE THICKNESS. SHEET METAL SCREWS ARE NOT ALLOWED; INSTEAD, UTILIZE LAP JOINTS OR RIVETS FOR ASSEMBLY.
I. SUPPORTS:
a. STRAP AND ROD SIZES: COMPLY WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND
FLEXIBLE," TABLE 5-1 (TABLE 5-1M), "RECTANGULAR DUCT HANGERS MINIMUM SIZE," AND TABLE 5-2, "MINIMUM
HANGER SIZES FOR ROUND DUCT."
b. HANGER ROD: GALVANIZED-STEEL RODS AND NUTS
c. STRAPS: GALVANIZED STEEL COMPLYING WITH ASTM A603.
d. HANGER RODS FOR CORROSIVE ENVIRONMENTS: ELECTROGALVANIZED, ALL-THREAD RODS OR GALVANIZED
RODS WITH THREADS PAINTED WITH ZINC-CHROMATE PRIMER AFTER INSTALLATION.
4. DUCT ACCESSORIES
A. MANUFACTURERS: AIR BALANCE INC, RUSKIN, AMERICAN WARMING AND VENTILATING, UNITED MCGILL, TUTTLE AND
BAILEY, DUCTMATE, DURO DYNE, OTHER APPROVED EQUALS.
B. BACKDRAFT DAMPERS: LOW LEAKAGE WITH MULTIPLE SINGLE-PIECE BLADES AND SEALED EDGES, PARALLEL BLADE
ACTION, RETURN SPRINGS AS REQUIRED FOR OPERATION.
a. SEE PLANS FOR ACTUATOR TYPE (GRAVITY OR MOTORIZED). MOTORIZED SHALL BE CLASS 1 LOW LEAKAGE.
b. VOLUME DAMPERS: STEEL, LEAKAGE RATING CLASS III, OUT OF AIRSTREAM LINKAGE, SUITABLE FOR HORIZONTAL
AND VERTICAL AIRFLOW, MULTIPLE OR SINGLE BLADE AS REQUIRED, AND LOCKING DEVICE TO HOLD DAMPER
BLADES IN A FIXED POSITION WITHOUT VIBRATION.
c. PROVIDE REMOTE OPERATED DAMPER WHEN DAMPER IS LOCATED ABOVE HARD LID OR INACCESSIBLE
LOCATION.
C. TURNING VANES: MANUFACTURED FOR METAL DUCTS, GALVANIZED SHEET STEEL, SINGLE WALL VANES/BLADES, SUPPORT BARS PERPENDICULAR TO BLADES, SET INTO VANE RUNNERS AND SUITABLE FOR DUCT MOUNTING. SINGLE- VANE, CURVED BLADES OF GALVANIZED SHEET STEEL; SUPPORT WITH BARS PERPENDICULAR TO BLADES AND SET INTO
VANE RUNNERS SUITABLE FOR DUCT MOUNTING.
D. DUCT MOUNTED ACCESS DOORS: DOUBLE WALL RECTANGULAR, GALVANIZED, HINGES AND LATCHES, AIRTIGHT AND SUITABLE FOR DUCT PRESSURE CLASS. SHALL COMPLY WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE"; FIGURE 7-2 (7-2M), "DUCT ACCESS DOORS AND PANELS," AND FIGURE 7-3, "ACCESS DOORS -
ROUND DUCT."
E. FLEXIBLE CONNECTORS: FLAME SPREAD NOT EXCEEDING 25 AND SMOKE DEVELOPED INDEX NOT EXCEEDING 50, COMPLY WITH ASHRAE 62.1, FLAME RETARDANT MATERIAL, METAL EDGED CONNECTORS AND APPROXIMATELY 3-1/2"
THICK FLEXIBLE MATERIAL.
5. FLEX DUCT: CONSTRUCTED OF HIGH-QUALITY, DURABLE MATERIALS CAPABLE OF WITHSTANDING TEMPERATURE VARIATIONS AND AIR PRESSURE, SHALL FEATURE A SPRING STEEL HELIX TO PROVIDE STRUCTURAL SUPPORT AND MAINTAIN FLEXIBILITY, DIAMETER TO MATCH PLANS, 1" THICK FIBERGLASS INSULATION, AND LEAK RESISTANT CONNECTIONS.AIR OUTLETS -
REGISTERS, GRILLES, AND DIFFUSERS
A. MANUFACTURERS: TITUS, PRICE, KRUEGER, NAILER, TUTTLE AND BAILEY
B. SEE SCHEDULES FOR TYPES, MATERIALS, AND ADDITIONAL REQUIREMENTS.
C. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO COORDINATE QUANTITIES AND BORDER TYPES.
D. PROVIDE BORDER TYPE TO FIT CEILING TYPE.
6. LOUVERS
A. MANUFACTURERS: RUSKIN, GREENHECK, AIR BALANCE, UNITED ENERTECH.
B. ALUMINUM AND WELDED CONSTRUCTION.
C. ARCHITECTURAL SYSTEM WITH HIDDEN MULLIONS.
D. PROVIDE FREE AREA, DEPTH, AND AIR VELOCITY AS SCHEDULED.
E. COLOR BY ARCHITECT.
F. PROVIDE WITH BIRD SCREEN.
G. LOUVER SHALL BE STATIONARY UNLESS OTHERWISE INDICATED.
PART 3 - EXECUTION (CONT.)
E. EXHAUST OR RELIEF
a. WITHIN CONDITIONED SPACE, DOWNSTREAM OF AN ENERGY RECOVERY MEDIA, UPSTREAM OF AN AUTOMATIC
SHUTOFF DAMPER, CLIMATE ZONE 4C: R-8 INSULATION
b. WITHIN CONDITIONED SPACE, DOWNSTREAM OF AN ENERGY RECOVERY MEDIA, UPSTREAM OF AN AUTOMATIC
SHUTOFF DAMPER, CLIMATE ZONE 5B: R-12 INSULATION
c. CONDITIONED SPACE AND DOWNSTREAM OF AN AUTOMATIC SHUTOFF DAMPER, CLIMATE ZONE 4C OR 5B: R-16
INSULATION.
F. PENETRATIONS
a. ROOF PENETRATIONS: INSTALL INSULATION CONTINUOUSLY THROUGH ROOF PENETRATIONS. SEAL PENETRATIONS WITH FLASHING SEALANT. FOR APPLICATIONS REQUIRING ONLY INDOOR INSULATION, TERMINATE INSULATION ABOVE ROOF SURFACE AND SEAL WITH JOINT SEALANT. FOR APPLICATIONS REQUIRING INDOOR AND OUTDOOR INSULATION, INSTALL INSULATION FOR OUTDOOR APPLICATIONS TIGHTLY JOINED TO INDOOR INSULATION ENDS. SEAL JOINT WITH JOINT SEALANT. EXTEND JACKET OF OUTDOOR INSULATION OUTSIDE ROOF FLASHING AT LEAST 2 INCHES (50 MM) BELOW TOP OF ROOF FLASHING. SEAL JACKET TO ROOF
FLASHING WITH FLASHING SEALANT.
b. EXTERIOR WALL PENETRATIONS: SEAL PENETRATIONS WITH FLASHING SEALANT. FOR APPLICATIONS REQUIRING ONLY INDOOR INSULATION, TERMINATE INSULATION INSIDE WALL SURFACE AND SEAL WITH JOINT SEALANT. FOR APPLICATIONS REQUIRING INDOOR AND OUTDOOR INSULATION, INSTALL INSULATION FOR OUTDOOR APPLICATIONS TIGHTLY JOINED TO INDOOR INSULATION ENDS. SEAL JOINT WITH JOINT SEALANT. EXTEND JACKET OF OUTDOOR INSULATION OUTSIDE WALL FLASHING AND OVERLAP WALL FLASHING AT LEAST 2 INCHES
(50 MM). SEAL JACKET TO WALL FLASHING WITH FLASHING SEALANT.
6. DUCTWORK
A. INSTALL DUCTS IN ACCORDANCE WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE"
UNLESS OTHERWISE INDICATED.
B. INSTALL DUCTS IN MAXIMUM PRACTICAL LENGTHS WITH FEWEST POSSIBLE JOINTS.
C. INSTALL FACTORY- OR SHOP-FABRICATED FITTINGS FOR CHANGES IN DIRECTION, SIZE, AND SHAPE AND FOR BRANCH
CONNECTIONS.
D. EXTERIOR WALL DUCT PENETRATIONS SHALL BE FLASHED AND COUNTER-FLASHED AT THE WALL WITH AN OVERLAP OF
METAL JACKET AND ESCUTCHEON PLATE. CALK AND SEAL PENETRATION WATERTIGHT. PROVIDE A SLEEVE FOR THE PENETRATION AND FILL THE GAPS BETWEEN THE DUCT AND THE PENETRATION/WALL WITH JOINT SEALANT/CAULK.
E. UNLESS OTHERWISE INDICATED, INSTALL DUCTS VERTICALLY AND HORIZONTALLY, AND PARALLEL AND PERPENDICULAR
TO BUILDING LINES.
F. INSTALL DUCTS CLOSE TO WALLS, OVERHEAD CONSTRUCTION, COLUMNS, AND OTHER STRUCTURAL AND PERMANENT
ENCLOSURE ELEMENTS OF BUILDING.
G. INSTALL DUCTS WITH A CLEARANCE OF 1 INCH (25 MM), PLUS ALLOWANCE FOR INSULATION THICKNESS.
H. WHERE DUCTS PASS THROUGH NON-FIRE-RATED INTERIOR PARTITIONS AND EXTERIOR WALLS AND ARE EXPOSED TO
VIEW, COVER THE OPENING BETWEEN THE PARTITION AND DUCT OR DUCT INSULATION WITH SHEET METAL FLANGES OF SAME METAL THICKNESS AS THE DUCT. OVERLAP OPENINGS ON FOUR SIDES BY AT LEAST 1-1/2 INCHES (38 MM).
I. INSTALL FIRE, COMBINATION FIRE/SMOKE, AND SMOKE DAMPERS WHERE INDICATED ON DRAWINGS AND AS REQUIRED
BY CODE, AND BY LOCAL AUTHORITIES HAVING JURISDICTION.
J. ROUTE DUCTS TO AVOID PASSING THROUGH TRANSFORMER VAULTS AND ELECTRICAL EQUIPMENT ROOMS AND
ENCLOSURES.
K. SEAL DUCTS FOR DUCT STATIC-PRESSURE, SEAL CLASSES, AND LEAKAGE CLASSES SPECIFIED IN "DUCT SCHEDULE" ARTICLE IN ACCORDANCE WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE."
L. MAKE CONNECTIONS TO EQUIPMENT WITH FLEXIBLE CONNECTORS
M. BRANCH CONNECTIONS: USE LATERAL OR CONICAL BRANCH CONNECTIONS.
N. TEST DUCTWORK FOR LEAKAGE PER SMACNA HVAC DUCT LEAKAGE TEST PROCEDURES AND AS REQUIRED BY LOCAL
CODES.
O. DURING CONSTRUCTION PROVIDE TEMPORARY CLOSURES OF METAL OR TAPED POLYETHYLENE AT ALL OPENINGS IN
DUCTWORK TO PREVENT CONSTRUCTION DUST FROM ENTERING DUCTWORK SYSTEM.
P. ALL 90-DEGREE RECTANGULAR ELBOWS SHALL CONTAIN TURNING VANES.
Q. SUPPORTS:
a. COMPLY WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE," CHAPTER 5, "HANGERS AND SUPPORTS."
b. BUILDING ATTACHMENTS: CONCRETE INSERTS, POWDER-ACTUATED FASTENERS, OR STRUCTURAL-STEEL FASTENERS APPROPRIATE FOR CONSTRUCTION MATERIALS TO WHICH HANGERS ARE BEING ATTACHED
c. WHERE PRACTICAL, INSTALL CONCRETE INSERTS BEFORE PLACING CONCRETE.
d. INSTALL POWDER-ACTUATED CONCRETE FASTENERS AFTER CONCRETE IS PLACED AND COMPLETELY CURED.
e. USE POWDER-ACTUATED CONCRETE FASTENERS FOR STANDARD-WEIGHT AGGREGATE CONCRETES OR FOR
SLABS MORE THAN 4 INCHES (100 MM) THICK
f. DO NOT USE POWDER-ACTUATED CONCRETE FASTENERS FOR LIGHTWEIGHT-AGGREGATE CONCRETES OR FOR
SLABS LESS THAN 4 INCHES (100 MM) THICK.
g. HANGER SPACING: COMPLY WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE,"
TABLE 5-1 (TABLE 5-1M), "RECTANGULAR DUCT HANGERS MINIMUM SIZE," AND TABLE 5-2, "MINIMUM HANGER SIZES FOR ROUND DUCT," FOR MAXIMUM HANGER SPACING; INSTALL HANGERS AND SUPPORTS WITHIN 24 INCHES (610 MM) OF EACH ELBOW AND WITHIN 48 INCHES (1220 MM) OF EACH BRANCH INTERSECTION.
h. HANGERS EXPOSED TO VIEW: THREADED ROD AND ANGLE OR CHANNEL SUPPORTS.
i. SUPPORT VERTICAL DUCTS WITH STEEL ANGLES OR CHANNEL SECURED TO THE SIDES OF THE DUCT WITH
WELDS, BOLTS, SHEET METAL SCREWS, OR BLIND RIVETS; SUPPORT AT EACH FLOOR AND AT A MAXIMUM
INTERVALS OF 16 FEET (5 M).
j. INSTALL UPPER ATTACHMENTS TO STRUCTURES. SELECT AND SIZE UPPER ATTACHMENTS WITH PULL-OUT, TENSION, AND SHEAR CAPACITIES APPROPRIATE FOR SUPPORTED LOADS AND BUILDING MATERIALS WHERE
USED.
7. DUCT ACCESSORIES
a. INSTALL DUCT ACCESSORIES IN ACCORDANCE WITH APPLICABLE DETAILS IN SMACNA'S "HVAC DUCT
CONSTRUCTION STANDARDS - METAL AND FLEXIBLE" FOR METAL DUCTS
b. INSTALL DUCT ACCESSORIES OF MATERIALS SUITED TO DUCT MATERIALS; USE GALVANIZED-STEEL
ACCESSORIES IN GALVANIZED-STEEL AND FIBROUS-GLASS DUCTS, STAINLESS STEEL ACCESSORIES IN
STAINLESS STEEL DUCTS, AND ALUMINUM ACCESSORIES IN ALUMINUM DUCTS.
c. INSTALL MOTORIZED LOW LEAKAGE DAMPERS ON INLET OF EXHAUST FANS.
d. WHERE MULTIPLE DAMPER SECTIONS ARE NECESSARY TO ACHIEVE REQUIRED DIMENSIONS, PROVIDE
REINFORCEMENT TO FULLY SUPPORT DAMPER ASSEMBLY WHEN FULLY CLOSED AT FULL SYSTEM DESIGN
STATIC PRESSURE.
e. INSTALL VOLUME DAMPERS AT POINTS ON SUPPLY, RETURN, AND EXHAUST SYSTEMS WHERE BRANCHES EXTEND FROM LARGER DUCTS. WHERE DAMPERS ARE INSTALLED IN DUCTS HAVING DUCT LINER, INSTALL DAMPERS WITH HAT CHANNELS OF SAME DEPTH AS LINER, AND TERMINATE LINER WITH NOSING AT HAT
CHANNEL. PLANS DO NOT ATTEMPT TO SHOW VOLUME DAMPERS.
f. INSTALL STEEL VOLUME DAMPERS IN STEEL DUCTS.
g. INSTALL ALUMINUM VOLUME DAMPERS IN ALUMINUM DUCTS.
h. SET DAMPERS TO FULLY OPEN POSITION BEFORE TESTING, ADJUSTING, AND BALANCING.
i. INSTALL TEST HOLES AT FAN INLETS AND OUTLETS AND ELSEWHERE AS INDICATED AND AS NEEDED FOR
TESTING AND BALANCING.
j. INSTALL FIRE AND SMOKE DAMPERS IN ACCORDANCE WITH UL LISTING.
k. INSTALL DUCT ACCESS DOORS ON SIDES OF DUCTS TO ALLOW FOR INSPECTING, ADJUSTING, AND MAINTAINING
ACCESSORIES AND EQUIPMENT
l. INSTALL ACCESS DOORS WITH SWING AGAINST DUCT STATIC PRESSURE.
m. INSTALL FLEXIBLE CONNECTORS TO CONNECT DUCTS TO EQUIPMENT.
8. AIR OUTLETS
A. INSTALL DIFFUSERS, REGISTERS, GRILLES AND LOUVERS LEVEL AND PLUMB. PROVIDE SQUARE-TO-ROUND
TRANSITIONS ON SUPPLY AIR DIFFUSERS WHERE REQUIRED TO CONNECT TO ROUND FLEXIBLE DUCTS. CONNECT FLEX
DUCT TO PLENUM WITH NYLON DRAWBANDS.
B. CEILING MOUNTED OUTLETS AND INLETS: DRAWINGS INDICATE GENERAL ARRANGEMENT OF DUCTS, FITTINGS, AND ACCESSORIES. AIR OUTLET AND INLET LOCATIONS HAVE BEEN INDICATED TO ACHIEVE DESIGN REQUIREMENTS FOR AIR VOLUME, NOISE CRITERIA, AIRFLOW PATTERN, THROW, AND PRESSURE DROP. MAKE FINAL LOCATIONS WHERE INDICATED, AS MUCH AS PRACTICABLE. FOR UNITS INSTALLED IN LAY-IN CEILING PANELS, LOCATE UNITS IN THE CENTER OF PANEL. WHERE ARCHITECTURAL FEATURES OR OTHER ITEMS CONFLICT WITH INSTALLATION, NOTIFY ARCHITECT
FOR A DETERMINATION OF FINAL LOCATION.
C. INSTALL DIFFUSERS, REGISTERS, AND GRILLES WITH AIRTIGHT CONNECTIONS TO DUCTS AND TO ALLOW SERVICE AND MAINTENANCE OF DAMPERS, AIR EXTRACTORS, AND FIRE DAMPERS. SEAL EXHAUST AND RETURN GRILLES TO RISER DUCTS IN A MANNER THAT DOES NOT ALLOW CEILING PLENUM AIR TO BYPASS IN TO DUCT CONNECTIONS.
9. ELECTRIC UNIT HEATERS
A. WALL MOUNTED: INSTALL PER NFPA 90A. INSTALL LEVEL AND PLUMB WITH WALL MOUNTED THERMOSTATS TO MATCH
LIGHTING CONTROL HEIGHT UNLESS OTHERWISE INDICATED. INSTALL WITH RECESSED FACTORY KIT. ALL WIRING IS TO
BE CONCEALED.
10. POWER VENTILATORS
A. INSTALL POWER VENTILATORS LEVEL AND PLUMB.
B. EQUIPMENT MOUNTING:
a. SECURE ROOF-MOUNTED FANS TO ROOF CURBS WITH ZINC-PLATED HARDWARE.
b. CEILING UNITS: SUSPEND UNITS FROM STRUCTURE; USE STEEL WIRE OR METAL STRAPS.
C. INSTALL UNITS WITH CLEARANCES FOR SERVICE AND MAINTENANCE
D. DRAWINGS INDICATE GENERAL ARRANGEMENT OF DUCTS AND DUCT ACCESSORIES. MAKE FINAL DUCT CONNECTIONS
WITH FLEXIBLE CONNECTORS
E. CONNECT WIRING ACCORDING TO "LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES." REQUIREMENTS.
F. GROUND EQUIPMENT. INSTALL ELECTRICAL DEVICES FURNISHED BY MANUFACTURER, BUT NOT FACTORY MOUNTED, ACCORDING TO NFPA 70 AND NECA 1.
G. COMPLETE INSTALLATION AND STARTUP CHECKS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.
11. DEMONSTRATION AND TRAINING
A. CONTRACTOR TO TRAIN OWNER’S MAINTENANCE PERSONNEL TO ADJUST, OPERATE AND MAINTAIN THE ENTIRE HVAC
SYSTEM.
PART 2 - PRODUCTS (CONT.)
7. ELECTRIC UNIT HEATERS
A. MANUFACTURES: BROAN, INDEECO, Q-MARK, MODINE, BRASCH, KING, OR EQUAL.
B. REMOVABLE PANELS, BAKED ENAMEL FINISH WITH COLOR BY ARCHITECT.
C. SURFACE MOUNTED CABINET ENCLOSURE AS INDICATED.
D. PROVIDE RECESSED WALL MOUNTING STYLE UNLESS INDICATED OTHERWISE.
E. UNIT SHALL HAVE ELECTRIC RESISTANCE HEATING COIL, FAN, MOTOR, 7 DAY PROGRAMMABLE THERMOSTAT, AND
FACTORY DISCONNECT.
8. POWER VENTILATORS
A. MANUFACTURERS: COOK, GREENHECK, PENN VENTILATION, TWIN CITY FAN.
B. COMPLY WITH NEMA DESIGNATION, TEMPERATURE RATING, SERVICE FACTOR, AND EFFICIENCY REQUIREMENTS FOR
MOTORS
C. INLINE VENTILATORS:
a. HOUSING: STEEL OR ALUMINUM WITH 1" FIBERGLASS DUCT LINER.
b. FAN WHEEL: BACKWARD INCLINED CENTRIFUGAL WHEEL, STATICALLY & DYNAMICALLY BALANCED.
c. MOTOR: PERMANENTLY LUBRICATED, SEALED BALL BEARING.
d. PROVIDE WITH ECM AND MANUAL SPEED ADJUSTMENT DIAL.
e. PROVIDE WITH DISCONNECT.
PART 3 - EXECUTION
1. SUPPORTS
A. CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE WEIGHTS OF THE SUPPORTED PIPING, EQUIPMENT
AND/OR DUCTWORK, BASED ON SIZES, HANGER SUPPORT SPACING AND OPERATING LOADS. ALL HANGERS, RODS, CLEVISES, CROSS-SUPPORT MEMBERS, ETC. SHALL BE SIZED AND LOCATED BY THE CONTRACTOR BASED ON THESE LOADS AND THE RECOMMENDATIONS OF THE SUPPORT PRODUCT MANUFACTURERS OR EQUIVALENT STRUCTURAL DESIGN PRACTICES. ADEQUACY OF BUILDING STRUCTURAL ELEMENTS TO BARE ALL UPPER EQUIPMENT SUPPORT ANCHORS POINTS SHALL BE THE CONTRACTOR’S RESPONSIBILITY THROUGH THE INFORMATION PROVIDED ON THE
ARCHITECTURAL AND STRUCTURAL DRAWINGS.
B. DESIGN EQUIPMENT SUPPORTS CAPABLE OF SUPPORTING COMBINED OPERATING WEIGHT OF SUPPORTED EQUIPMENT
AND CONNECTED SYSTEMS AND COMPONENTS.
C. DESIGN SEISMIC-RESTRAINT HANGERS AND SUPPORTS FOR PIPING AND EQUIPMENT AND OBTAIN APPROVAL FROM
AUTHORITIES HAVING JURISDICTION.
D. COMPLY WITH MFMA-102 FOR METAL FRAMING SYSTEM SELECTIONS AND APPLICATIONS THAT ARE NOT SPECIFIED IN
PIPING SYSTEM SECTIONS.
E. USE POWDER-ACTUATED FASTENERS OR MECHANICAL-EXPANSION ANCHORS INSTEAD OF BUILDING ATTACHMENTS
WHERE REQUIRED IN CONCRETE CONSTRUCTION.
2. VIBRATION ISOLATION
A. FLOOR MOUNTED EQUIPMENT: MOUNT WITH ELASTOMERIC PADS SIZED FOR THE EQUIPMENT WEIGHT AND FOOTPRINT.
PROVIDE FLEXIBLE CONNECTIONS FOR DUCTWORK AND PIPING.
B. ROOF MOUNTED EQUIPMENT: ROOF CURB WITH NEOPRENE GASKET UNLESS DRAWINGS INDICATED SPRING ISOLATION
ROOF CURB OR DETAILS INDICATE OTHERWISE.
C. STRUCTURE SUSPENDED: ELASTOMERIC HANGERS OR SPRING HANGERS DESIGNED FOR EQUIPMENT WEIGHT AND
FOOTPRINT. PROVIDE FLEXIBLE CONNECTIONS FOR DUCTWORK AND PIPING.
3. IDENTIFICATION OF HVAC
A. PROVIDE PERMANENT EQUIPMENT LABELS, PIPE LABELS, AND DUCT LABELS INDICATION EQUIPMENT TYPE AND NUMBER, PIPE TYPE AND FLOW DIRECTION, AND DUCT TYPE AND FLOW DIRECTION.
B. CLEAN EQUIPMENT PRIOR TO INSTALL OF LABELS. PERMANENTLY FASTEN LABELS ON EACH ITEM OF MECHANICAL
EQUIPMENT.
C. PROVIDE LAY-IN CEILING LABELS INDICATING PANEL TO BE REMOVED FOR EQUIPMENT TO BE ACCESSED DIRECTLY
ABOVE CEILING.
4. TESTING, ADJUSTING, AND BALANCING
A. EXAMINE THE CONTRACT DOCUMENTS TO BECOME FAMILIAR WITH PROJECT REQUIREMENTS AND TO DISCOVER
CONDITIONS IN SYSTEMS DESIGNS THAT MAY PRECLUDE PROPER TAB OF SYSTEMS AND EQUIPMENT.
B. EXAMINE THE APPROVED SUBMITTALS FOR HVAC SYSTEMS AND EQUIPMENT.
C. EXAMINE DESIGN DATA, INCLUDING HVAC SYSTEM DESCRIPTIONS, STATEMENTS OF DESIGN ASSUMPTIONS FOR
ENVIRONMENTAL CONDITIONS AND SYSTEMS OUTPUT, AND STATEMENTS OF PHILOSOPHIES AND ASSUMPTIONS ABOUT
HVAC SYSTEM AND EQUIPMENT CONTROLS.
D. PREPARE A TAB PLAN THAT INCLUDES EQUIPMENT SYSTEMS TO BE TESTED, PROCEDURES FOR BALANCING SYSTEM, INSTRUMENTS TO BE USED, AND SAMPLE FORMS WITH SPECIFIC IDENTIFICATION FOR ALL EQUIPMENT.
E. PERFORM TESTING AND BALANCING PROCEDURES ON EACH SYSTEM IN ACCORDANCE WITH THE PROCEDURES CONTAINED IN NEBB'S "PROCEDURAL STANDARDS FOR TESTING, ADJUSTING, AND BALANCING OF ENVIRONMENTAL
SYSTEMS" AND IN THIS SECTION.
F. CUT INSULATION, DUCTS, PIPES, AND EQUIPMENT CASINGS FOR INSTALLATION OF TEST PROBES TO THE MINIMUM
EXTENT NECESSARY FOR TAB PROCEDURES
G. AFTER TESTING AND BALANCING, PATCH PROBE HOLES IN DUCTS WITH SAME MATERIAL AND THICKNESS AS USED TO
CONSTRUCT DUCTS.
H. WHERE HOLES FOR PROBES ARE REQUIRED IN PIPING OR HYDRONIC EQUIPMENT, INSTALL PRESSURE AND
TEMPERATURE TEST PLUGS TO SEAL SYSTEMS.
I. INSTALL AND JOIN NEW INSULATION THAT MATCHES REMOVED MATERIALS. RESTORE INSULATION, COVERINGS, VAPOR
BARRIER, AND FINISH IN ACCORDANCE WITH INSULATION REQUIREMENTS.
J. DRY SIDE: VERIFY THAT LEAKAGE AND PRESSURE TESTS ON AIR DISTRIBUTION SYSTEMS HAVE BEEN SATISFACTORILY COMPLETED, DUCT SYSTEMS ARE COMPLETE WITH TERMINALS INSTALLED, VOLUME, SMOKE, AND FIRE DAMPERS ARE OPEN AND FUNCTIONAL, CLEAN FILTERS ARE INSTALLED, FANS ARE OPERATING, FREE OF VIBRATION, AND ROTATING IN CORRECT DIRECTION, VARIABLE-FREQUENCY CONTROLLERS' STARTUP IS COMPLETE AND SAFETIES ARE VERIFIED, AUTOMATIC TEMPERATURE-CONTROL SYSTEMS ARE OPERATIONAL, CEILINGS ARE INSTALLED, WINDOWS AND DOORS
ARE INSTALLED, SUITABLE ACCESS TO BALANCING DEVICES AND EQUIPMENT IS PROVIDED.
K. SYSTEM ADJUSTING: HVAC SYSTEMS SHALL BE BALANCED IN ACCORDANCE WITH GENERALLY ACCEPTED ENGINEERING STANDARDS. AIR AND WATER FLOW RATES SHALL BE MEASURED AND ADJUSTED TO DELIVER FINAL FLOW RATES WITHIN 10% OF THE DESIGN VALUE OR WITHIN 10 CFM IF DESIGN CFM IS BELOW 100. TEST AND BALANCE ACTIVITIES
SHALL INCLUDE AIR SYSTEM AND HYDRONIC SYSTEM BALANCING.
L. AIR SYSTEM BALANCING: EACH SUPPLY AIR OUTLET AND ZONE TERMINAL DEVICE SHALL BE EQUIPPED WITH MEANS FOR AIR BALANCING IN ACCORDANCE WITH THE REQUIREMENTS OF CHAPTER 6 OF THE INTERNATIONAL MECHANICAL CODE.
DISCHARGE DAMPERS USED FOR AIR SYSTEM BALANCING ARE PROHIBITED ON CONSTANT VOLUME FANS AND VARIABLE VOLUME FANS WITH MOTORS 10 HP (18.6 KW) AND LARGER. AIR SYSTEMS SHALL BE BALANCED IN A MANNER TO FIRST MINIMIZE THROTTLING LOSSES THEN, FOR FANS WITH SYSTEM POWER OF GREATER THAN 1 HP (0.74 KW), FAN SPEED SHALL BE ADJUSTED TO MEET DESIGN FLOW CONDITIONS. EXCEPTION: FANS WITH FAN MOTORS OF 1 HP (0.74 KW) OR
LESS.
M. SYSTEM TESTING: FUNCTIONAL PERFORMANCE TESTING SHALL DEMONSTRATE THE COMPONENTS, SYSTEMS, AND SYSTEM-TO-SYSTEM INTERFACING RELATIONSHIPS ARE INSTALLED AND OPERATE IN ACCORDANCE WITH APPROVED CONSTRUCTION DOCUMENTS. TESTING SHALL INCLUDE THE SEQUENCE OF OPERATION, AND BE CONDUCTED UNDER FULL-LOAD, PART-LOAD AND THE FOLLOWING CONDITIONS: ALL MODES CAPABLE OF THE EQUIPMENT; REDUNDANT OR AUTOMATIC BACK-UP MODE; PERFORMANCE OF ALARMS; AND MODE OF OPERATION UPON A LOSS OF POWER AND
RESTORATION OF POWER.
5. DUCT INSULATION
A. DUCTWORK SHALL BE INSULATED PER THE REQUIREMENTS BELOW. DUCTWORK WITHIN THE BUILDING SHALL BE
FIBERGLASS WITH FSK COVERING. DUCTWORK ON THE EXTERIOR OF THE BUILDING SHALL BE BOARD INSULATION WITH ALUMINUM JACKET. EXPOSED TYPE I, COMMERCIAL, KITCHEN HOOD EXHAUST DUCT AND PLENUM INSULATION SHALL BE FIRE-RATED BLANKET OR BOARD; THICKNESS AS REQUIRED TO ACHIEVE 2-HOUR FIRE RATING.
B. OUTDOOR AIR:
a. INSIDE CONDITIONED SPACE AND UPSTREAM OF AUTOMATIC SHUTOFF DAMPER, IN CLIMATE ZONE 4C OR 5B, AND
GREATER THAN 2800 CFM: R-16 INSULATION
b. INSIDE CONDITIONED SPACE AND DOWNSTREAM OF AUTOMATIC SHUTOFF DAMPER TO HVAC UNIT OR ROOM, IN
CLIMATE ZONE 4C, AND GREATER THAN 2800 CFM: R-8 INSULATION
c. INSIDE CONDITIONED SPACE AND DOWNSTREAM OF AUTOMATIC SHUTOFF DAMPER TO HVAC UNIT OR ROOM, IN
CLIMATE ZONE 5B, AND GREATER THAN 2800 CFM: R-12 INSULATION
d. INSIDE CONDITIONED SPACE, IN CLIMATE ZONE 4C OR 5B, AND LESS THAN 2800 CFM: R-7 INSULATION.
C. SUPPLY AND RETURN AIR
a. OUTSIDE THE BUILDING (OUTDOORS AND EXPOSED TO WEATHER), CLIMATE ZONE 4C: R-8 INSULATION. COVER
WITH METAL JACKETING AND ENSURE ADEQUATE WATER PROOFING.
b. OUTSIDE THE BUILDING (OUTDOORS AND EXPOSED TO WEATHER), CLIMATE ZONE 5B: R-12 INSULATION. COVER
WITH METAL JACKETING AND ENSURE ADEQUATE WATER PROOFING.
c. UNCONDITIONED SPACE (ENCLOSED BUT NOT IN THE BUILDING CONDITIONED ENVELOPE), CLIMATE ZONE 4C OR
5B: R-6 INSULATION
d. UNCONDITIONED SPACE WHERE THE DUCT CONVEYS AIR THAT IS WITHIN 15°F OF THE AIR TEMPERATURE OF THE
SURROUNDING UNCONDITIONED SPACE, CLIMATE ZONE 4C OR 5B: R-3.3 INSULATION
e. WHERE LOCATED IN A BUILDING ENVELOPE ASSEMBLY, CLIMATE ZONE 4C OR 5B: R-16 INSULATION
D. SUPPLY AIR
a. WITHIN CONDITIONED SPACE WHERE THE SUPPLY DUCT CONVEYS AIR THAT IS LESS THAN 55°F OR GREATER
THAN 105°F, CLIMATE ZONE 4C OR 5B: R-3.3 INSULATION
b. WITHIN CONDITIONED SPACE WHERE THE SUPPLY DUCT CONVEYS AIR THAT IS GREATER THAN 55°F AND LESS
THAN 105°F, CLIMATE ZONE 4C OR 5B: NO INSULATION REQUIRED.
SPOKANE, WA
WWW.ES-ENG.COM
Project number
Date
Drawn by
Checked by
SHEET TITLE:
M0.2
MECHANICAL
SPCIFICATIONS
25.10
N E W
C O
N C E S S
IO
N S
R E S T R O
O M
S
PERMIT SET
04/29/25
LJH
LJG
H E R M
IS
T O
N S
C H
O O
L D
IS
T R
IC
T
S
O U
T H
S T S
T R E E T
H E R M
IS
T O
N
O R E G
O N
K N
E R R C
O N
S T R U
C T
IO
N
IN
C
SPOKANE, WA
WWW.ES-ENG.COM
Project number
Date
Drawn by
Checked by
SHEET TITLE:
M0.3
MECHANICAL
SCHEDULES
25.10
N E W
C O
N C E S S
IO
N S
R E S T R O
O M
S
PERMIT SET
04/29/25
LJH
LJG
H E R M
IS
T O
N S
C H
O O
L D
IS
T R
IC
T
S
O U
T H
S T S
T R E E T
H E R M
IS
T O
N
O R E G
O N
K N
E R R C
O N
S T R U
C T
IO
N
IN
C
5) PROVIDE WITH 7-DAY PROGRAMMABLE TIMER SWITCH FOR ENABLING & DISABLING FANS ON SCHEDULE (ADJ.).
4) PROVIDE FACTORY DISCONNECT.
3) PROVIDE EC MOTOR WITH POTENTIOMETER ON MOTOR.
2) PROVIDE FLEXIBLE DUCT CONNECTORS.
1) PROVIDE VIBRATION ISOLATION HANGING KIT.
NOTES:
SF-1 GREENHECK SQ-VG SUPPLY INLINE 700 DIRECT 0.5 1/4 0.1 208/1 2.1 15 60 6.2 7.2 ALL
EF-1 GREENHECK SQ-VG EXHAUST INLINE 700 DIRECT 0.5 1/4 0.1 208/1 2.1 15 60 6.2 7.2 ALL
HP BHP V/PH FLA MOCP INLET OUTLET
TAG MFR MODEL SERVICE TYPE
AIRFLOW
(CFM)
DRIVE
ESP
("WC)
MOTOR ELECTRICAL WEIGHT
(LBS)
SONES
NOTES
HVAC FAN SCHEDULE
3) INCLUDES HANDHELD IR REMOTE WITH WALL HOLDER.
2) IP55 RATED HEATER
1) INCLUDES ADJUSTABLE ANGLE MOUNTING BRACKET. COORDINATE FINAL MOUTNING LOCATION WITH OWNER/GC.
NOTES:
IH-1 KING RK2045-RMT-BLK CONCESSIONS 01 4.5 12.62" 60" 6.5" 15 LBS 208/1 21.6 30 ALL
HEIGHT WIDTH DEPTH WEIGHT V/PH AMPS MOCP
TAG MFR MODEL SERVICE KW
DIMENSIONS ELECTRICAL
NOTES
INFRARED RADIANT HEATER SCHEDULE
4) FIELD CONVERT TO LOWER WATTAGE.
3) COORIDNATE W/ OWNER TO PROVIDE BMS RELAY AS NEEDED.
2) INCLUDES INTEGRAL TAMPER-RESISTANT ADJUSTABLE THERMOSTAT, 14 GA SECURITY FRONT COVER, & DISCONNECT.
1) PROVIDE RECESSED INSTALLATION AT LEAST 8" AFF, UNLESS OTHERWISE NOTED.
NOTES:
EWH-3 BRASCH 933B FAMILY RR 05 WALL HEATER 100 1.5 47 19-5/16 15-3/4 3-3/4 208/1 7.2 ALL
EWH-2 BRASCH 933B WOMEN'S RR 04 WALL HEATER 100 3 94 19-5/16 15-3/4 3-3/4 208/1 14.5 1-3
EWH-1 BRASCH 933B MEN'S RR 02 WALL HEATER 100 3 94 19-5/16 15-3/4 3-3/4 208/1 14.5 1-3
HEIGHT WIDTH DEPTH V/PH AMPS
TAG MFR MODEL SERVICE TYPE
AIRFLOW
(CFM)
KW
RISE
(°F)
DIMENSIONS (") ELECTRICAL
NOTES
ELECTRIC WALL HEATER SCHEDULE
3) PROVIDE LOW VOLTAGE THERMOSTAT. HEATING SETPOINT SHALL BE LIMITED TO 55°F (ADJ.) FOR FREEZE PROTECTION.
2) PROVIDE FACTORY MOUNTED & WIRED DISCONNECT.
1) PROVIDE MFR'S MOUNTING BRACKET.
NOTES:
UH-2 BRASCH 925 CONCESSION 01 ELECTRIC 270 3.1 60 12.5" 14" 20" 24 LBS 208/1 15 ALL
UH-1 BRASCH 925 STORAGE/JAN 03 ELECTRIC 270 1.9 60 12.5" 14" 20" 24 LBS 208/1 9 1,2
HEIGHT WIDTH DEPTH WEIGHT V/PH AMPS
TAG MFR MODEL SERVICE TYPE
AIRFLOW
(CFM)
KW
TEMP
RISE
(°F)
DIMENSIONS ELECTRICAL
NOTES
ELECTRIC UNIT HEATER SCHEDULE
3) INCLUDES TERMINAL BLOCKS, 24V CONTROL TRANSFORMER, & DISCONNECT SWITCH.
2) PROVIDE SCR MODULATION.
1) PROVIDE AIRFLOW SWITCH & DUCT STAT TO CONTROL BASED ON LAT.
NOTES:
DH-1 GREENHECK IDHE 700 16" x 16" 394 15 10 75 SCR W/ LAT SENSOR 208/3 42 ALL
V/PH AMPS
TAG MFR MODEL
AIRFLOW
(CFM)
DUCT SIZE
VELOCITY OVER
COIL (FPM)
KW
EAT
(°F)
LAT
(°F)
CONTROL
ELECTRICAL
NOTES
ELECTRIC DUCT HEATER SCHEDULE
5) VERIFY CEILING & WALL CONSTRUCTION ON ARCHITECTURAL DRAWINGS. PROVIDE CORRECT FRAME TYPES. COORDINATE WITH ARCHITECT FOR FINAL BORDER TYPE,STYLE, AND CEILING TYPE.
4) ADJUST DEFLECTORS TO OPTIMIZE AIRFLOW PATTERN IN SPACE.
3) PROVIDE 24"x24" PAN FOR LAY-IN CEILING INSTALLATION, AS REQ'D.
2) PROVIDE TRANSITION FROM AIR OUTLET TO DUCT AS REQUIRED. PROVIDE BALANCING DAMPER IN THE BRANCH DUCT SERVING AIR OUTLET AT TAKEOFF FROM TRUNK DUCT.
1) PAINT INSIDE SURFACE OF THE DUCTWORK BLACK UNLESS OTHERWISE PROVIDED WITH DUCT LINER.
NOTES:
2 PRICE 535
RETURN/
EXHAUST
GRILLE STEEL
CEILING/
SURFACE
FOR
APPLICATION
FIXED HORIZ. WHITE 1/2" FIXED 45 1,2,3,5
1 PRICE SMCD SUPPLY
ADJ.
LOUVERED
DIFFUSER
STEEL
CEILING/
SURFACE
FOR
APPLICATION
4-WAY ADJ. WHITE 1" ADJ. - ALL
SPACING POS. DEFL (°)
TAG MFR MODEL SERVICE TYPE MATERIAL MOUNTING BORDER PATTERN FINISH
BLADE
NOTES
GRILLES, REGISTERS, & DIFFUSERS SCHEDULE
4) COORDINATE FRAME DEPTH WITH WALL TYPE, WALL THICKNESS, & OTHER TRADES PRIOR TO ORDERING.
3) COORDINATE COLOR WITH ARCHITECT/OWNER.
2) PROVIDE MOTORIZED CLASS 1 SHUT-OFF DAMPER. COORDINATE WITH ELECTRICIAN TO INTERLOCK LOUVER DAMPER WITH RESPECTIVE FAN.
1) PROVIDE WITH BIRD SCREEN. MOUNT FLUSH WITH EXTERIOR WALL AT 9' 6" AFF UNLESS OTHERWISE COORDINATED.
NOTES:
L-2 GREENHECK ESD-435 ALUMINUM SF-1 INTAKE 700 30 18 4 1.58 443 0.03 ALL
L-1 GREENHECK ESD-435 ALUMINUM EF-1 EXHAUST 700 30 18 4 1.58 443 0.03 ALL
TAG MFR MODEL MATERIAL SERVICE TYPE
AIRFLOW
(CFM)
WIDTH
HEIGHT
FRAME DEPTH
FREE AREA
(SQ FT)
VELOCITY
(FPM)
APD
NOTES
LOUVER SCHEDULE
MEN'S
WOMEN'S
STORAGE/JANITORIAL
FAMILY RR
CONCESSION
A A
B B
UH-1
UH-2
IH-1
EWH-1
EWH-2
EWH-3
8"x8" 2 240
8"x8" 2 225
8"x8" 2 90
8"x8" 2 145
EF-1
DH-1SF-1
L-1
L-2
"ø
"ø
12"x12"
"x
12"x12"
16"x16"
12"x12"
"ø
"ø
"ø
"ø
8"x8" 1 225
6"x6" 1 90
10"x10" 1 240 10"x10" 1
12"x12"
"ø
2 2
M
M
SPOKANE, WA
WWW.ES-ENG.COM
Project number
Date
Drawn by
Checked by
SHEET TITLE:
M1.1
MECHANICAL FLOOR
PLAN
25.10
N E W
C O
N C E S S
IO
N S
R E S T R O
O M
S
PERMIT SET
04/29/25
LJH
LJG
H E R M
IS
T O
N S
C H
O O
L D
IS
T R
IC
T
S
O U
T H
S T S
T R E E T
H E R M
IS
T O
N
O R E G
O N
K N
E R R C
O N
S T R U
C T
IO
N
IN
C
N 1/2" = 1'-0"
HVAC FLOOR PLAN
KEY NOTES:
PROVIDE A MINIMUM OF 10' SEPARATION BETWEEN EXHAUST
& INTAKE LOUVERS.
12"x12" DUCT DOWN THRU CEILING TO ACCESSIBLE
EQUIPMENT LOCATED BELOW THE CEILING. SEAL CEILING
PENETRATIONS AIRTIGHT.
DOUBLE NUTS AND
WASHERS TO MATCH
ROD SIZE
HORIZONTAL ANGLE /
CHANNEL SUPPORT
THREADED ROD
DUCT
STRUCTURE STRUCTURE
LOAD RATED FASTENERS
NOTES:
1. RECTANGULAR DUCTS LESS THAN 60" WIDE ARE PERMITTED TO USE GALVANIZED
HANGER STRAP RATHER THAN ALL THREAD. SUPPORT PER SMACNA.
2. ON RECTANGULAR DUCTS OVER 48" WIDE, BOTTOM SHALL BE BRACED BY ANGLE. FOR
CROSS SECTION AREA MORE THAN 8 SQ FT, DUCT SHALL BE BRACED BYANGLES ON ALL
FOUR SIDES.
3. ROUND DUCTS LESS THAN 36"ø ARE PERMITTED TO BE SUPPORTED FROM A SINGLE
HANGER STRAP
4. SUPPORTS SHALL BE SPACED AND SIZED AS PER SMACNA.
"W"
S U
P P
L Y
A
IR
F L O
W
MAIN BRANCH DUCT
L= 1/4 "W OR 4"MIN.
BRANCH DUCT
45°
"L"
ALL BRANCH CONNECTIONS SHALL BE
PROVIDED WITH DAMPER WITH LOCKING
QUADRANT OR YOUNG'S REGULATOR IN
CEILING IF DAMPER IN NOT ACCESSIBLE. INSTALL
DAMPER A MINIMUM OF 2*W FROM TAKEOFF.
NOTES:
1. ROUND DUCTWORK MAY USE CONICAL
DUCT TAKE-OFF FITTING.
2. INSTALL PER SMACNA HVAC DUCT
CONSTRUCTION STANDARDS.
3. SEE PRESSURE CLASS REQUIREMENTS
IN SPECIFICATIONS.R
E
T U
R N
/E X
H A
U S
T
SUPPLY AIR FLOW
RETURN/EXHAUST
SEE PLANS FOR DUCTWORK
FLOW DIRECTION (IE. SUPPLY,
RETURN, EXHAUST)
COLOR BY
ACHITECT
LOUVER ASSEMBLY
BIRDSCREEN
NOTES:
NOTES:
1. CLIP ANGLES AND EXTENDED SILL TO
BE PROVIDED BY LOUVER
MANUFACTURER IF REQUIRED.
2. INSTALLATION OF LOUVER TO BE IN
ACCORDANCE WITH LOUVER
MANUFACTURER'S
RECOMMENDATIONS AND PROJECT
SPECIFICATIONS.
SLOPE DUCT CONNECTIONS
TOWARDS
THE OUTSIDE
SEAL AND
CAULK AROUND
ALL EDGES
CEILING
VIBRATION
ISOLATOR,
TYP.
IN-LINE FANFLEX CONNECTOR,
TYP.
DUCT
HORIZONTAL MOUNTING
R SHALL
EQUAL OR
BE GREATER
THAN W.
STANDARD RADIUS OR
LONG RADIUS ELBOW
W
R
W
W1
NOTES:
1. ALL VANE ELBOWS SHALL BE CONSTRUCTED
AND INSTALLED AS DETAILED BY SMACNA.
2. VANES SHALL BE SINGLE THICKNESS. ALL
SINGLE THICKNESS VANES SHALL HAVE A 2"
RADIUS, 1 1/2" MAXIMUM SPACE BETWEEN
VANES AND A 3/4" TRAILING EDGE.
3. PROVIDE DUCT LINER AS INDICATED ON
PLANS.
NOTES:
1. RADIUS ELBOW SHALL BE USED ON ALL
KITCHEN HOOD GREASE EXHAUST
DUCTWORK, DISHWASHER EXHAUST
DUCTWORK AND AS AN OPTION TO
RECTANGULAR ELBOWS WITH TURNING
VANES.
SPIN-IN FITTING, MANUAL BALANCE DAMPER, WITH LOCKING QUADRANT,
2" INSULATION STANDOFF & 3/8" SOLID DAMPER ROD
PROVIDE SAFETY CABLE PER SEISMIC REQUIREMENTS
ACOUSTICALLY LINED RECTANGULAR SUPPLY DUCT, SEE PLANS FOR SIZE
A
IR
F L O
W
CEILING DIFFUSER - SEE PLANS FOR TYPE AND SIZE
R-6 INSULATED FLEXIBLE DUCT
5FT MAX LENGTH
SPIRAL SEAM ROUND DUCT - SEE PLANS FOR SIZES
AIR FLOW
90° RIGID OR ADJUSTABLE SHEET
METAL ELBOW
C.L.
SQUARE TO ROUND DIFFUSER
ADAPTER OR ROUND NECK INLET
LAY-IN CEILING DIFFUSER
LAY-IN CEILING
RIGID OR ADJUSTABLE
SHEETMETAL ELBOW
SUPPORT STRAPS
INSULATED FLEX DUCT (MAXIMUM 5')
SURFACE MOUNT CEILING DIFFUSER
GWB CEILING
SECURE FLEX DUCT TO
SHEETMETAL ELBOW WITH
TAPE AND POSITIVE LOCKING
STRAPS PER SPECIFICATIONS
SPIN-IN FITTING, MANUAL BALANCE DAMPER, WITH LOCKING QUADRANT,
2" INSULATION STANDOFF & 3/8" SOLID DAMPER ROD
PROVIDE SAFETY CABLE PER SEISMIC REQUIREMENTS,
AS REQ'D
ACOUSTICALLY LINE RECTANGULAR RETURN DUCT.
SEE PLANS FOR SIZE
A
IR
F L O
W
CEILING GRILLE - SEE PLANS FOR TYPE AND SIZE
R-6 INSULATED FLEXIBLE DUCT,
5FT MAX LENGTH
BRANCH RETURN DUCT
SEE PLANS FOR SIZE
AIR FLOW
PLENUM BOX SIZED TO MATCH
GRILLE NECK
SQUARE TO ROUND TRANSITION
INACCESSIBLE
CEILING
STAINLESS
WIRE. 50'
MAX
SUPPLY DIFFUSER
DAMPER (ROUND OR
RECTANGULAR)
WITH
LINKAGE ASSEMBLY
FLEXIBLE DUCTWORK
RIGID DUCTWORK
CONCEALED REGULATOR KIT EQUAL TO YOUNG
REGULATOR CABLE CONTROLLER WITH SOCKET HEAD
ADJUSTMENT SHAFT, COVER PLATE, CASING, WIRE,
DAMPER AND ACTUATOR WITH CABLE ACTIVATED
ADJUSTMENTS.
FLEX DUCT SUPPORT
SPOKANE, WA
WWW.ES-ENG.COM
Project number
Date
Drawn by
Checked by
SHEET TITLE:
M3.1
MECHANICAL DETAILS
25.10
N E W
C O
N C E S S
IO
N S
R E S T R O
O M
S
PERMIT SET
04/29/25
LJH
LJG
H E R M
IS
T O
N S
C H
O O
L D
IS
T R
IC
T
S
O U
T H
S T S
T R E E T
H E R M
IS
T O
N
O R E G
O N
K N
E R R C
O N
S T R U
C T
IO
N
IN
C
NTS
DUCT HANGER
NTS
DUCT TAKE-OFF FITTINGS
NTS
LOUVER
NTS
TYPICAL INLINE FAN
NTS
TYPICAL DUCT ELBOWS
NTS
SUPPLY DIFFUSER CONNECTION
NTS
RETURN GRILLE DETAIL - CEILING
NTS
REMOTE VOLUME DAMPER
VALVE (AS INDICATED OR SPECIFIED)
PRESSURE & TEMPERATURE RELIEF VALVE
VALVE IN VALVE BOX (AS INDICATED OR SPECIFIED)
OR
PRESSURE GAUGE
GAS SHUTOFF COCK
PRESSURE REDUCING VALVE/REGULATOR
GLOBE VALVE, ANGLE
GLOBE VALVE
HOSE BIBB
MOTOR-OPERATED VALVE
2-WAY CONTROL VALVE
3-WAY CONTROL VALVE
SOLENOID-OPERATED VALVE
DOUBLE CHECK BACK FLOW PREVENTER
GATE SHUTOFF VALVE ANGLE
GATE SHUTOFF VALVE
VENT-THRU-ROOF
WALL CLEANOUT
FLOOR DRAIN, ROUND
FLOOR CLEAN OUT
FLOOR SINK
WATER FLOW METER STATION
TRENCH DRAIN
TEMPERATURE GAUGE
PUMP (POINT IN DIRECTION OF FLOW)
FLOOR DRAIN, SQUARE
VTR
CIRCUIT SETTER
CHECK VALVE (ARROW TOWARD DIRECTION OF FLOW)
REDUCED PRESSURE BACK FLOW PREVENTER
M
S
FMS
BUTTERFLY VALVE
BALL VALVE
FLEXIBLE CONNECTION, BRAIDED
UNION
PIPE CAP
STRAINER
REDUCER
FLOW DIRECTION INDICATOR
INDICATES DIRECTION OF DOWNWARD PITCH
PIPE TEE BRANCH DOWN (W/ ELBOW)
PIPE ELBOW DOWN
PIPE TEE BRANCH UP (W/ ELBOW)
AIR RELIEF VENT
PIPE ELBOW UP
P##
P##
TAG
CROSS-SECTION SYMBOL
(TOP=SECTION NUMBER,BOTTOM=SHEET NUMBER)
DETAIL SYMBOL
(TOP=DETAIL NUMBER, BOTTOM=SHEET NUMBER)
POINT OF CONNECTION (POC) SYMBOL
EQUIPMENT IDENTIFIER (SEE SCHED.)
(TOP=EQUIPMENT TYPE, BOTTOM=EQUIPMENT NUMBER)
KEY NOTES
PLUMBING FIXTURE IDENTIFIER (SEE SCHED.)
REVISION NUMBER
P-#
PLUMBING ABBREVIATIONSPLUMBING SYMBOLS
GENERAL SYMBOLS
PLUMBING GENERAL NOTES COORDINATION NOTES
LINE WEIGHT LEGEND
OR
OR
A. ALL WORK SHALL COMPLY WITH THE OWNERS REQUIREMENTS, AND WITH
ALL APPLICABLE STATE AND LOCAL CODES, OR AUTHORITY HAVING
JURISDICTION.
B. PROVIDE SEISMIC RESTRAINTS FOR ALL PIPE AND EQUIPMENT REQUIRED BY
SEISMIC DESIGN CRITERIA. CONSULT LOCAL SEISMIC CODES FOR THE
SEISMIC RATING OF THE AREA IN WHICH THE PROJECT IS BEING BUILT.
C. SUBSTITUTIONS OF EQUIPMENT OTHER THAN AS SPECIFIED SHALL BE THE
COMPLETE RESPONSIBILITY OF THE HVAC CONTRACTOR. ANY ADDITIONAL
ELECTRICAL, STRUCTURAL, MECHANICAL OR ARCHITECTURAL
REQUIREMENTS SHALL BE PROVIDED AT NO ADDITIONAL EXPENSE TO
OWNER.
D. PLUMBING PLANS DO NOT SHOW ALL PIPING AND COMPONENTS. REFER TO
DETAILS, SCHEDULES, AND SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
E. HANGERS AND SUPPORTS FOR THE PLUMBING SYSTEM AND EQUIPMENT
ARE NOT SHOWN OR DESIGNED WITHIN THESE DRAWINGS. THE
CONTRACTOR SHALL PROVIDE ALL NECESSARY HANGERS, SUPPORTS,
BRACKETS, HARDWARE, ETC TO SUPPORT THE PLUMBING SYSTEM.
F. DO NOT HANG OR BRACE PIPING OR EQUIPMENT DIRECTLY FROM METAL
DECKING. PIPING AND EQUIPMENT SHALL BE SUPPORTED FROM
STRUCTURAL MEMBERS.
G. ENSURE THAT ALL ELECTRICAL PANELS AND EQUIPMENT HAVE THE
REQUIRED WORKING CLEARANCE AS PER NEC. OFFSET PIPING AS NEEDED
TO MAINTAIN CLEARANCES.
H. COLD AND HOT WATER SUPPLY PIPING SIZES FOR FIXTURE CONNECTIONS
MAY NOT BE SHOWN ON PLANS. SEE FIXTURE SCHEDULE FOR CONNECTION
SIZES.
I. PROVIDE SEAL BETWEEN WALLS AND PLUMBING FIXTURES. PROVIDE
ESCUTCHEON PLATE AT THE PIPE PENETRATION.
J. LOCATE AND LABEL ALL VALVES FOR SERVICE ACCESSIBILITY. VALVES
INSTALLED ABOVE CEILINGS SHALL BE ACCESSIBLE THROUGH CEILING. SEE
DRAWINGS FOR LOCATIONS. VALVES LOCATED BEHIND HARD LID CEILINGS
OR IN WALLS SHALL BE PROVIDED WITH AN ACCESS HATCH/BOX.
K. PROVIDE PIPING EQUIPMENT, VALVES, CONNECTIONS, AND MATERIALS IN
ACCORDANCE WITH APPLICABLE PLUMBING CODE REGULATIONS AND
STANDARDS, AUTHORITIES HAVE JURISDICTION, AS RECOMMENDED BY
MANUFACTURER, AND AS REQUIRED IN SPECIFICATIONS.
L. PIPING PENETRATIONS THROUGH…