Exhibit 1 - Permitted HSD Concession -Restrooms.pdf

PDF 15 MB Posted

Attached to
Weber Concession & Bathroom Building
Solicitation number
S-P30001-00014684
Issued by
Union County, Oregon

About this file

These architectural construction documents are for a small commercial building project prepared by Engineering Northwest, LLC, specifically a concession and restroom facility with a professional engineering seal dated 04/15/2025. The project involves constructing a single-story building with approximately 9,000 square feet, classified as a Business (B) occupancy under Type V-B construction. The facility includes a concession area, men's and women's restrooms, a family restroom, and a janitorial space. The design incorporates standard commercial building features with concrete slab foundation, CMU (concrete masonry unit) walls, metal roofing, and manufactured roof trusses. The project is designed to meet the 2022 Oregon Structural Specialty Code (O.S.S.C.) requirements, with specific attention to energy efficiency, accessibility, and safety standards.

Key technical specifications include a maximum building height of 40 feet, an occupant load of 3 persons, and no fire sprinkler or fire alarm system requirements. The construction details emphasize moisture resistance, weatherproofing, and energy efficiency, with specifications for wall insulation, roof ventilation, and exterior door and window installations. The design includes specific architectural elements like luxury vinyl plank flooring, rubber wall base, gypsum wall board finishes, and suspended ceiling at 8 feet above finished floor. Structural details include continuous reinforced concrete footings, hurricane ties, and specific requirements for wall reinforcement, lintel construction, and roof diaphragm design. The project is set to renew on 6/30/2026 and was initially prepared in March 2012, with the most recent revision made on 04/15/2025.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RENEWS 6/30/2026

85283PE

P A T

J. WOOD

CO

C K

LA

NO

IS

SEFORPDERETSI

GER

MARCH 8, 20

IF THIS BAR SCALE DOES NOT

MEASURE 1" THEN THIS DRAWING

IS NOT TO SCALE

A S3

A S3

S2 W

CONCESSION

36' - 0" (OUT-TO-OUT OF CMU)

MEN'S

12' - 0" 4' - 3 3/8"

O U

T-

TO

-O U

T O

F C

M U

RR-1

S3

A

C

B S3

3' - 4" 4' - 0"3' - 4"

B

WOMEN'S

4' - 6 1/2"

3'

/2

3' - 4" 8 5/8"

B

A

3 4

STORAGE/JANITORIAL

FAMILY

RESTROOM

C O

U N

TE

R

TO

P

W / B

AS

E

C

AB

IN

ET

S

C O

U N

TE

R

TO

P

W / B

AS

E

C

AB

IN

ET

S

4' - 0 1/8" 3' - 4" 11' - 3 3/8"3' - 4"12' - 0"

36' - 0"

S2 S

S2 N

S2 E

RR-2

S3

RR-3

S3

D

5' - 0"

9'

/8

4'

1/

4"

3/

8"

1' - 3 7/8"

8 5/8"

3' - 11 3/8"12 5/8"

FLOOR DRAIN

(TYP.)

C S3

5' x 6'

CONC.

LANDING

(TYP.)

9 3

MOP SINK

(A.P.O.)

/4

8'

0" 9'

4"

8'

0"

CODE OVERVIEW

OCCUPANCY CLASSIFICATION:

B- BUSINESS

TYPE OF CONSTRUCTION:

V-B

SPECIAL DET. REQ'S BASED ON USE & OCC. (CH. 4):

NONE

ALLOWABLE HEIGHT & AREA (CH. 5) :

ALLOWABLE HEIGHT: 40'-0"

ALLOWABLE AREAS: 9,000 ft²

FIRE RATING OF EXTERIOR WALLS (T.705.5):

10ft < x < 30ft, : 0 HOURS

WALL & CEILING FINISHES (SEC. 803)

B-CLASS 'C' - NO RESTRICTIONS

FIRE SPRINKLER SYSTEM (SECTION 903):

NOT REQUIRED

2022 O.S.S.C.

FIRE ALARM SYSTEM (SECTION 907) :

NOT REQUIRED

OCCUPANT LOAD (T. 1004.5):

CONCESSION: 293 ft² /200 = 2 STORAGE: 152 ft² /300 = 1

TOTAL OCCUPANCY = 3

EGRESS WIDTHS (SEC. 1005):

DOORWAYS: 34" MINIMUM WIDTH REQUIRED

NUMBER OF EXITS REQUIRED (SEC. 1006) :

ONE - OCCUPANT LOAD < 49

TRAVEL DISTANCE (TABLE 1017.2) :

200 ft.

VENTILATION (SEC. 1202):

NOT REQ'D, EXCEPTION #1

TEMPERATURE CONTROL (SEC. 1203):

ACTIVE OR PASSIVE HEATING SYSTEM IS REQ'D

LIGHTING (SEC. 1204):

NATURAL OR ARTIFICIAL LIGHTING IS REQ'D

CONSTRUCTION NOTES

1. COORDINATE ALL PLUMBING, HVAC & ELECTRICAL REQUIREMENTS W/ THE OWNER.

2. COORDINATE ALL ROOM, WALL & FLOOR FINISH, DOOR HARDWARE & WINDOW REQUIREMENTS WITH OWNER.

3. ALL DOORS & WINDOWS SHALL COMPLY WITH THE LATEST REQUIREMENTS OF THE 2022 OREGON STRUCTURAL SPECIALTY CODE

(O.S.S.C.)

4. ALL WEATHER PROOFING, AIR & VAPOR BARRIERS SHALL BE CONTINUOUS IN WALL/FLOOR/ROOF SYSTEMS WITH ALL

PENETRATIONS & CONNECTIONS PROPERLY SEALED PER MANUFACTURERS RECOMMENDATIONS &/OR THE AUTHORITY

HAVING JURISDICTION.

5. ALL POWER/ELECTRICAL, LIGHTING, VENTILATION, HEATING & AIR CONDITIONING, PLUMBING, SMOKE & FIRE ALARMS SHALL COMPLY WITH THE REQUIREMENTS OF THE 2022 OREGON STRUCTURAL SPECIALTY CODE (O.S.S.C.)

6. WALL FIRE BLOCKING SHALL NOT EXCEED 10'-0" O.C.

7. COORDINATE ALL INSULATION R-VALUES, DOOR & WINDOW U-VALUES, ETC. WITH THE 2021 OREGON ENERGY EFFICIENCY

SPECIALTY CODE.

8. ALL WINDOW SIZES ARE GIVEN IN INCHES & THE CMU ROUGH OPENING SIZE (Eg. 3220 = 32" WIDE BY 20" R.O.)

9. ALL DOOR SIZES ARE GIVEN IN FEET & INCHES (Eg. 3070 = 3'-0" WIDE BY 7'-0" TALL)

10. ANY/ALL GLAZING WITHIN 24" OF A DOOR OR 18" FROM A FLOOR SHALL BE TEMPERED OR SAFETY GLASS.

11. PROVIDE MECHANICAL EXHAUST FANS IN RESTROOMS AS PER CODE REQ'S.

12. EMERGENCY EXIT SIGN WITH BATTERY BACK-UP LIGHTING, REQUIRED AT ALL DESIGNATED EXIT DOORS & RISER ROOM. ALL EXIT

SIGNS ARE REQUIRED TO BE INTERNALLY ILLUMINATED AND INCLUDE BATTERY BACKUP.

13. THE OCCUPANT LOAD SHALL BE POSTED ON A PERMANENT AND LEGIBLE SIGN.

14. FIRE EXTINGUISHER QUANTITY, TYPE & LOCATION TO BE COORDINATED W/ LOCAL FIRE DEPARTMENT.

15. PANIC HARDWARE IS REQUIRED ON ALL EXIT DOORS AND DOORS WITHIN THE EXIT PASSAGEWAYS.

INSULATION & FENESTRATION REQ'D

CLIMATE

ZONE

WINDOW

U-FACTOR

SWINGING

DOOR

U-VALUE

ROOF

R-VALUE

MASS WALL

U-VALUE

FLOOR

R-VALUE

SLAB

R-VALUE

5B

CRAWL

SPACE

NON-SWINGING

DOOR

R-VALUE

N/A U-0.37 R-49 U-0.090 N/A R-15 for 24" BGS N/AR-5

ENERGY CODE COMPLIANCE 2021 O.E.E.S.C.

NOTES:

1. SHGC ≤ 0.38, VT/SHGC ≤ 1.10

2. THESE ARE MINIMUMS. ENGINEER STRONGLY RECOMMENDS TO INSULATE ABOVE THESE MINIMUMS TO PREVENT HEAT LOSS & INCREASE ENERGY EFFICIENCY.

PLUMBING REQUIREMENTS (2022 O.S.S.C., TABLE 2902.1)

OCCUPANCY

TYPE

B

NUMBER OF

OCCUPANTS

WATER CLOSET

CODE RATIO

1 per 25

MEN WOMEN

LAVATORYS

CODE RATIO

MEN WOMEN

WATER CLOSET

REQUIRED

MEN WOMEN

LAVATORYS

REQUIRED

MEN WOMEN

0.041 per 40 0.06

NOTES:

1. (1) ADA DRINKING FOUNTAIN OR ACCESSIBLE WATER DISPENSER IS REQUIRED.

2. (1) SINGLE OCCUPANT ADA RESTROOM HAS BEEN APPROVED BY THE BUILDING OFFICIAL VS. (1) MALE R.R. & (1) FEMALE R.R.

1 per 25 1 per 40 0.06 0.04

1 WALL TYPE #1

WALL TYPES#

WALL TYPE #33

WALL TYPE #22

WALL TYPE #44

WALL NOTES:

1. GYPSUM WALL BOARD TO BE FASTENED TO WALL STUDS WITH #8 DRYWALL SCREWS @ 8" O.C. IN THE FIELD AND 4" AT PANEL

EDGES. STAGGERS PANEL JOINTS EACH RUN.

2. GYPSUM CEILING BOARD TO BE FASTENED TO CEILING JOISTS WITH #8 DRYWALL SCREWS @ 6" IN THE FIELD & 4" AT PANEL

EDGES. STAGGER PANEL JOINTS EACH RUN.

3. GYPSUM WALL BOARD TO BE TAPED & TEXTURED AS PER OWNER. PRIME LIBERALLY WITH PVA & PAINT

WITH PREMIUM GRADE, WASHABLE LATEX (SEE OWNER FOR DETAILS)

12" HI-R

CMU WALL

COLOR &

STYLE PER

OWNER

WATER RESISTANT

PANEL @ 48" MIN.

A.F.F.

5/8" MOISTURE RESISTANT

GYPSUM WALL BOARD

2x6 DF-L #2 WALL

STUDS @ 16" O.C.

WATER RESISTANT

PANEL @ 48" MIN.

A.F.F.SOUND

INSULATION

WATER RESISTANT

PANEL @ 48" MIN.

A.F.F.

2x6 DF-L #2 WALL

STUDS @ 16" O.C.

WATER RESISTANT

PANEL @ 48" MIN.

A.F.F.

SOUND

INSULATION

CONFESSION

5/8" MOISTURE RESISTANT

GYPSUM WALL BOARD

12" HI-R

CMU WALL

COLOR &

STYLE PER

OWNER

INTERIOR INTERIOR

JANITORIAL

1) POPCORN POPPER AS PER OWNER.

2) TURBO CHEF OVEN, SEE OWNER FOR DETAILS.

3) REFRIGERATOR AS PER OWNER.

4) CASH REGISTER AS PER OWNER.

5) CHEESE WARMER AS PER OWNER.

6) UNDERCOUNTER WARMING STATION AS PER OWNER.

EQUIPMENT KEY NOTES#

7) 3-COMPARTMENT SINK AS PER OWNER.

8) HAND-WASHING STATION AS PER OWNER.

9) TOWEL DISPENSER AS PER OWNER.

10) SOAP DISPENSER AS PER OWNER.

11) STORAGE CABINET AS PER OWNER.

SHEET NO. ____ OF ______

JOB NO. ________________

TH

IS

D

RA

W

IN

G

IS

T

HE

S

OL

E

PR

OP

ER

TY

O

F

EN

GI

NE

ER

IN

G

NO

RT

HW

ES

T, LL

C.

A

ND

S

HA

LL

N

OT

B

E

RE

PR

OD

UC

ED

O R

US

ED

IN

A

NY

F

OR

M

OR

M

AN

NE

R, N

OR

A

RE

T

HE

Y

TO

B

E

AS

SI

GN

ED

T

O A

TH

IR

D

PA

RT

Y

W

IT

HO

UT

F

IR

ST

O

BT

AI

NI

NG

T

HE

W

RI

TT

EN

C

ON

SE

NT

O F

EN

GI

NE

ER

IN

G

NO

RT

HW

ES

T, LL

C.

A

NY

R

EP

RO

DU

CT

IO

N

IN

P

AR

T

OR

A

S A

W

HO

LE

IS

S

TR

IC

TL

Y

PR

OH

IB

IT

ED

. S

HO

UL

D

UN

AU

TH

OR

IZ

ED

R

EU

SE

O

CC

UR

, E

NG

IN

EE

RI

NG

N

OR

TH

W

ES

T, LL

C.

S

HA

LL

B

E

HE

LD

H

AR

ML

ES

S.

N ew

C on ce ss io n

R es tr oo m s:

So ut h 1s t S tre et , H er m is to n, O re go n

Kn er r C on st ru ct io n In c.

N st

S t #

2, H er m is to n, O

R

MA

RK

RE

VI

SI

ON

D

ES

CR

IP

TI

ON

DA

TE

R ev ie w ed B y:

D ra w n

By

Ap pr ov ed

B y:

Pr in t D at e:

D W

G S ca le

M

AR

25-016

AS

N

O

TE

D

P.

H

PA

T

W O

O D

C O

C K

DATE SEALED: _____________________04/15/2025

He rm is to n Sc ho ol

D is tr ic t

PA

T W

O O

D C

O C

K

RE

VI

SI

ON

P

ER

C

LIE

NT

R

EV

IE

W

/15

/20

4/15/2025 11:01:08 AM

M

AI

N F

LO

O

R

PL

AN

S1

3/8" = 1'-0"1 FLOOR PLAN SEE DOOR & WINDOW

TYPES ON SHEET S3

IF THIS BAR SCALE DOES NOT

MEASURE 1" THEN THIS DRAWING

IS NOT TO SCALE

T.O. CONC.

100' - 0"

T.O. TOP OF CMU

108' - 8"

A S3

CONT. RIDGE

VENT

GRADEGRADE

MTL ROOFING

(A.P.O.)

A A B

12" HI-R

CMU

T.O. CONC.

100' - 0"

T.O. TOP OF CMU

108' - 8"

A S3

CONT. RIDGE

VENT

GRADE GRADE

MTL ROOFING

(A.P.O.)

12" HI-R

CMU

CB

T.O. CONC.

100' - 0"

T.O. TOP OF CMU

108' - 8"

GRADE

GRADE

12" HI-R

CMU

BOARD & BATT

SIDING (OR A.P.O.)

MTL ROOFING

(A.P.O.)

D

NEW LED WALL PACK

AS PER OWNER (TYP.)

T.O. CONC.

100' - 0"

T.O. TOP OF CMU

108' - 8"

GRADE

GRADE

12" HI-R

CMU

BOARD & BATT

SIDING (OR A.P.O.)

MTL ROOFING

(A.P.O.)

NEW LED WALL PACK

AS PER OWNER (TYP.)

SHEET NO. ____ OF ______

JOB NO. ________________

TH

IS

D

RA

W

IN

G

IS

T

HE

S

OL

E

PR

OP

ER

TY

O

F

EN

GI

NE

ER

IN

G

NO

RT

HW

ES

T, LL

C.

A

ND

S

HA

LL

N

OT

B

E

RE

PR

OD

UC

ED

O R

US

ED

IN

A

NY

F

OR

M

OR

M

AN

NE

R, N

OR

A

RE

T

HE

Y

TO

B

E

AS

SI

GN

ED

T

O A

TH

IR

D

PA

RT

Y

W

IT

HO

UT

F

IR

ST

O

BT

AI

NI

NG

T

HE

W

RI

TT

EN

C

ON

SE

NT

O F

EN

GI

NE

ER

IN

G

NO

RT

HW

ES

T, LL

C.

A

NY

R

EP

RO

DU

CT

IO

N

IN

P

AR

T

OR

A

S A

W

HO

LE

IS

S

TR

IC

TL

Y

PR

OH

IB

IT

ED

. S

HO

UL

D

UN

AU

TH

OR

IZ

ED

R

EU

SE

O

CC

UR

, E

NG

IN

EE

RI

NG

N

OR

TH

W

ES

T, LL

C.

S

HA

LL

B

E

HE

LD

H

AR

ML

ES

S.

N ew

C on ce ss io n

R es tr oo m s:

So ut h 1s t S tre et , H er m is to n, O re go n

Kn er r C on st ru ct io n In c.

N st

S t #

2, H er m is to n, O

R

MA

RK

RE

VI

SI

ON

D

ES

CR

IP

TI

ON

DA

TE

R ev ie w ed B y:

D ra w n

By

Ap pr ov ed

B y:

Pr in t D

G S ca le

M

AR

25-016

AS

N

O

TE

D

P.

H

PA

T

W O

O D

C O

C K

DATE SEALED: _____________________04/15/2025

He rm is to n Sc ho ol

D is tr ic t

PA

T W

O O

D C

O C

K

RE

VI

SI

ON

P

ER

C

LIE

NT

R

EV

IE

W

/15

/20

4/15/2025 11:01:12 AM

EX

TE

RI

O

R

EL

EV

AT

IO

N

S

S2

3/8" = 1'-0"E EAST ELEVATION

3/8" = 1'-0"W WEST ELEVATION

3/8" = 1'-0"S SOUTH ELEVATION

3/8" = 1'-0"N NORTH ELEVATION

P A T

J. WOOD

CO

C K

LA

NO

IS

SEFORPDERETSI

GER

MARCH 8, 20

IF THIS BAR SCALE DOES NOT

MEASURE 1" THEN THIS DRAWING

IS NOT TO SCALE

T.O. CONC.

100' - 0"

T.O. TOP OF CMU

108' - 8"

28 GA MTL ROOFING ON

MOISTURE BARRIER ON

7/16" O.S.B. ON MFG TRUSSES

12"x8"x16" HI-R-H

INSULATED CMU WALL

< R-49 ATTIC INSULATION REQ.>

24" 24"

GRADE GRADE

4" CONC.

SLAB

5/8" GYPSUM BD

MOP SINK

R-15 RIGID

INSUL. (TYP.)

ROOM FINISH SCHEDULE NOTES:

1. CONCRETE SLAB FLOOR PREPPED TO RECEIVE FINISH TILE, SEALER, OR OTHER FLOOR COVERING.

2. LUXURY VINYL PLANK FLOORING, STYLE & COLOR AS PER OWNER/TENANT.

3. 4" RUBBER WALL BASE, COLOR AS PER OWNER.

4. 5/8" GYPSUM WALL BOARD, AS PER "WALL TYPES" & NOTES ON SHEET (S1), & PRIMED PER NOTE (8).

5. RESTROOMS & OTHER AREAS SUBJECT TO MOISTURE, INSTALL 5/8" MOISTURE RESISTANT G.W.B. 48" A.F.F. &

PRIMED PER NOTE (9).

6. SUSPENDED HARD LID CEILING @ 8'-0" A.F.F. 5/8" GYPSUM BOARD, PRIMED & PAINTED PER NOTES (8 & 10)

7. LEVEL 4 WALL FINISH W/ SKIP TROWEL TEXTURE.

8. ONE LIBERAL COAT OF PVA PRIMER PRIOR TO COLOR PAINT.

9. WHITE EPOXY PAINT.

10. TWO COATS OF SHERWIN-WILLIAMS LATEX ENAMEL COLOR 7042 SHOJI WHITE AFTER PVA PRIMER.

11. NO WALL FINISH

12. NO CEILING FINISH.

01 CONCESSION 1

02 MEN'S RESTROOM 1

REMARKS

BASE

MATL

FLOOR

FINISH

ROOM NAME

ROOM FINISH SCHEDULE

MATL FINISH

ROOM #

MATL FINISH MATL FINISH MATL FINISH MATL FINISH MATL FINISH

NORTH WALL SOUTH WALL WEST WALL EAST WALL CEILING

03 JANITORIAL 1 4 4 4 4

7 4

75 5 5

4 7 4 7 4 7

7 7 7 7

3 11 11 11 11

8/10

8/10

8/9

04 WOMEN'S RESTROOM 1 4 4 4 4 743 11 11 11 11 8/9

05 FAMILY RESTROOM 1 4 4 4 4 743 11 11 11 11 8/9

DOOR TYPES

7'

0"

3' - 0"

KICK PLATE

EACH SIDE.

INSULATED

EXTERIOR DOOR W/ LOCKA

F.F.

9'-4" x 4'-8" ROLL-UP CONCESSION DOORD

9' - 4"

4'

8"

7'

0"

3' - 0"

KICK PLATE

EACH SIDE.

RESTROOM

SIGNAGE

INSULATED

EXTERIOR DOOR B

7'

0"

3' - 0"

KICK PLATE

EACH SIDE.

RESTROOM

SIGNAGE

INSULATED

EXTERIOR DOOR C

RESTROOM ELEVATIONS

NOTES:

1. TOILET FLUSH ACTIVATOR LOC'D @

OPEN SIDE OF ROOM.

2. CONTRCTOR SHALL PROVIDE & INSTALL

ALL OWNER REQ'D SUB-WALL BACKING

FOR SURFACE MOUNTED EQUIPMENT.

3. F.R.P. OVERLAYMENT WALL PANELING

REQUIRED ON EACH WALL TO 48" A.F.F.

4. INSULATE ALL EXPOSED DRAIN PIPING.

SOUTH

MEN'S RESTROOM ELEVATIONS

7"-9"

" M

IN

6"

42" BAR12" MAX

52" MIN.3070

EAST WEST

OF FINISH

18" CLR.

6"

60" MIN CLR.

36" MIN. CLR.

TO FINISH

18" CLR

30" MIN. CLR.

TO FINISH

15" CLR

" M

AX

" M

AX

9" M

IN

NORTH

" M

AX

WOMEN'S RESTROOM ELEVATIONS2

FAMILY RESTROOM ELEVATIONS3

NORTH SOUTH

WEST EAST

OF FINISH

18" CLR.

6"

60" MIN CLR.

36" MIN. CLR.

TO FINISH

18" CLR

" M

AX

" M

AX

9" M

IN

7"-9"

" M

IN

6"

42" BAR12" MAX

52" MIN.

" M

AX

OF FINISH

18" CLR.

6"

" M

AX

" M

AX

9" M

IN

NORTH

7"-9"

" M

IN

6"

42" BAR12" MAX

52" MIN.

EAST SOUTH

" M

AX

WEST

BABY CHANGER

(A.P.O.)

T.O. CONC.

100' - 0"

T.O. TOP OF CMU

108' - 8"

GRADE

< R-49 >

28 GA MTL ROOFING ON

MOISTURE BARRIER ON

7/16" O.S.B. ON MFG TRUSSES

12"x8"x16" HI-R-H

INSULATED CMU WALL

4" CONC.

SLAB

5/8" GYPSUM BD

R-15 RIGID

INSUL. (TYP.)

12" HI-R

CMU WALL

DOOR HEAD DETAIL

DOOR AS PER

DOOR TYPE

12 HI-R

CMU WALL

2" x 12"

P.T. TRIMMER

DOOR JAMB DETAIL

HOLLOW

METAL DOOR

FRAME

SEALANT

ALL-ROUND

DOOR AS PER

DOOR TYPE

12" HI-R CMU WALL

4" x 12"

P.T. SILL

COUNTER PER

DOOR MFG.

DOOR AS PER

DOOR TYPE

SEALANT

ALL-ROUND

DOOR SILL DETAIL

CONCESSION ROLL-UP H.M. DOOR - HEAD/JAMB/SILL DETAILS

MTL TRIM

12" HI-R

CMU WALL

4" x 12" P.T.

HEADER

DOOR HEAD DETAIL

HOLLOW

METAL DOOR

FRAMEDOOR AS PER

DOOR TYPE

SEALANT

ALL-ROUND

12 HI-R

CMU WALL

2" x 12"

P.T. TRIMMER

DOOR JAMB DETAIL

HOLLOW

METAL DOOR

FRAME

SEALANT

ALL-ROUND

DOOR AS PER

DOOR TYPE

DOOR THRESHOLD DETAIL

DOOR AS PER

DOOR TYPE SLOPE

CONC.

ALUMINUM

THRESHOLD

DOOR

SWEEP

EXTERIOR HOLLOW METAL DOOR - HEAD/JAMB/SILL DETAILS

T.O. CONC.

100' - 0"

T.O. TOP OF CMU

108' - 8"

GRADE

28 GA MTL ROOFING ON

MOISTURE BARRIER ON

7/16" O.S.B. ON MFG TRUSSES

4" CONC.

SLAB

5/8" GYPSUM BD

< R-49 >

R-15 RIGID

INSUL. (TYP.)

" M

AX

SHEET NO. ____ OF ______

JOB NO. ________________

TH

IS

D

RA

W

IN

G

IS

T

HE

S

OL

E

PR

OP

ER

TY

O

F

EN

GI

NE

ER

IN

G

NO

RT

HW

ES

T, LL

C.

A

ND

S

HA

LL

N

OT

B

E

RE

PR

OD

UC

ED

O R

US

ED

IN

A

NY

F

OR

M

OR

M

AN

NE

R, N

OR

A

RE

T

HE

Y

TO

B

E

AS

SI

GN

ED

T

O A

TH

IR

D

PA

RT

Y

W

IT

HO

UT

F

IR

ST

O

BT

AI

NI

NG

T

HE

W

RI

TT

EN

C

ON

SE

NT

O F

EN

GI

NE

ER

IN

G

NO

RT

HW

ES

T, LL

C.

A

NY

R

EP

RO

DU

CT

IO

N

IN

P

AR

T

OR

A

S A

W

HO

LE

IS

S

TR

IC

TL

Y

PR

OH

IB

IT

ED

. S

HO

UL

D

UN

AU

TH

OR

IZ

ED

R

EU

SE

O

CC

UR

, E

NG

IN

EE

RI

NG

N

OR

TH

W

ES

T, LL

C.

S

HA

LL

B

E

HE

LD

H

AR

ML

ES

S.

N ew

C on ce ss io n

R es tr oo m s:

So ut h 1s t S tre et , H er m is to n, O re go n

Kn er r C on st ru ct io n In c.

N st

S t #

2, H er m is to n, O

R

MA

RK

RE

VI

SI

ON

D

ES

CR

IP

TI

ON

DA

TE

R ev ie w ed B y:

D ra w n

By

Ap pr ov ed

B y:

Pr in t D

G S ca le

M

AR

25-016

AS

N

O

TE

D

P.

H

PA

T

W O

O D

C O

C K

DATE SEALED: _____________________04/15/2025

He rm is to n Sc ho ol

D is tr ic t

PA

T W

O O

D C

O C

K

RE

VI

SI

ON

P

ER

C

LIE

NT

R

EV

IE

W

/15

/20

4/15/2025 11:01:14 AM

BU

IL

DI

N

G

SE

CT

IO

N S

S3

1/2" = 1'-0"A A-BUILDING SECTION

1/2" = 1'-0"B B-BUILDING SECTION

1/2" = 1'-0"C C-BUILDING SECTION

P A T

J. WOOD

CO

C K

LA

NO

IS

SEFORPDERETSI

GER

MARCH 8, 20

IF THIS BAR SCALE DOES NOT

MEASURE 1" THEN THIS DRAWING

IS NOT TO SCALE

GENERAL:

1. THESE STRUCTURAL DRAWINGS ARE INTENDED TO PRESENT SUFFICIENT DIMENSIONS &

DETAILS TO LOCATE THE PRIMARY STRUCTURAL COMPONENTS. THE CONTRACTOR SHALL

COORDINATE THE LOCATION OF SECONDARY ELEMENTS, WALLS, OR MEMBERS RELATED TO

OTHER DISCIPLINES.

2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS & SITE COMPONENTS BEFORE STARTING WORK.

3. ALL MATERIALS & WORKMANSHIP SHALL CONFORM TO THE 2022 O.S.S.C.

4. THE CONTRACTOR IS RESPONSIBLE FOR THE STABILITY OF THE STRUCTURE PRIOR TO ITS

COMPLETION. THE DESIGN, ADEQUACY & SAFETY OF ERECTION BRACING, SHORING,

TEMPORARY SUPPORTS, ETC., IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR & HAS NOT

BEEN CONSIDERED BY THE ENGINEER.

5. CHANGES OR DEVIATIONS FROM DESIGN WILL NOT BE MADE WITHOUT APPROVAL FROM

ENGINEER.

DESIGN LOADS:

1. ROOF: DEAD LOAD: ....................................................... 15 PSF

COLLATERAL LOAD: .......................................... 5 PSF

LIVE LOAD: ......................................................... 20 PSF

GROUND SNOW LOAD, Pg: .............................. 30 PSF

FLAT-ROOF SNOW LOAD, Pf: ........................... 25 PSF

SNOW EXPOSURE FACTOR, CE: ..................... 1.0

SNOW LOAD IMPORTANCE FACTOR, Is: ......... 1.0 THERMAL FACTOR, Ct: ...................................... 1.0

2. WIND: BASIC WIND SPEED: ......................................... 115 MPH

EXPOSURE CATEGORY: ................................... C

IMPORTANCE FACTOR, Iw: ............................... 1.0

3. SEISMIC: IMPORTANCE FACTOR, Is: ............................... 1.0

OCCUPANCY CATEGORY: ................................ II

SITE CLASS: ....................................................... D

SPECTRAL RESPONSE ACCEL, SS: ................ 0.386

SPECTRAL RESPONSE ACCEL, S1: ................ 0.149

SPECTRAL RESPONSE COEFF, SDS: ............. 0.383

SPECTRAL RESPONSE COEFF, SD1: ............. 0.228

SEISMIC DESIGN CATERGORY: ...................... D

SEISMIC FORCE RESISTING SYSTEM:

(SPECIAL REINF. MASONRY SHEAR WALLS)

RESPONSE MODIFICATION FACTORS:

R: .............. 5.0 Ω: .............. 2.5

STRUCTURAL NOTES

FOOTING/FOUNDATION:

1. ALL NON-COMPACTABLE & ORGANIC MATERIALS SHALL BE REMOVED PRIOR TO COMPACTION OF

SUB-GRADE.

2. ALL IMPORTED SOIL THAT IS USED TO BACKFILL, &/OR ALL DISTURBED SOIL USED AS BACK FILL, &/OR DISTURBED SOIL, TO BE COMPACTED TO 95% OF MAXIMUM DRY DENSITY (ASTM D698).

3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COMPACTION TESTING OF SUB-GRADE SOILS.

4. AN ALLOWABLE SOIL PRESSURE OF 1500 PSF WAS USED IN DESIGN.

5. PLACE ALL FOOTINGS ON UNDISTURBED NATIVE SOIL OR COMPACTED STRUCTURAL FILL AS

PER 2022 O.S.S.C.

6. ALL ELEVATIONS LISTED ARE FROM FIRST SUB-FLOOR ELEVATION OF 100.00', U.N.O.

CONCRETE:

1. MINIMUM CLEAR CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE AS FOLLOWS

(UNLESS NOTED OTHERWISE):

A. CONCRETE PLACED DIRECTLY AGAINST THE EARTH TO HAVE 3 INCHES.

B. ALL FORMED SURFACES EXPOSED TO WEATHER OR EARTH:

#5 REBAR OR SMALLER ...........1 1/2 INCHES

#6 REBAR OR LARGER .............2 INCHES

2. REBAR HOOK & BEND RADIUS FOR 180°R & 90°R:

HOOK FOR #3 TO #7 BARS = R3"

HOOK FOR #8 TO #11 BARS = R6"

3. MINIMUM LENGTH OF LAPPED SPLICES SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE.

STAGGER SPLICES SO THAT NO TWO ADJACENT BARS ARE SPLICED IN THE SAME

LOCATION UNLESS SHOWN OTHERWISE.

REBAR SIZE SPLICE LENGTH

#4 24" #5 30"

4. REINFORCING BARS SHALL CONFORM TO ASTM A-615, GRADE 60. REINFORCEMENT YIELD

STRENGTH TO BE A MIN. OF 60.

5. MAKE ALL BARS CONTINUOUS AROUND CORNERS OR PROVIDE CORNER REBAR SPLICING OF

EQUAL SIZE AND SPACING.

6. COMPRESSION STRENGTH:

FOOTINGS: ................................... F'c = 3500 PSI

STEMWALLS: ................................... F'c = 3500 PSI SLABS: ................................... F'c = 4000 PSI

ANCHOR BOLTS:

1. ALL ANCHOR BOLTS SHALL BE ASTM F1554 BOLTS, UNLESS NOTED OTHERWISE:

BOLT DIAMETER EMBEDMENT LENGTH SPACING

5/8" 7" 24" O.C.

7. TYPICAL REINFORCING UNLESS NOTED DIFFERENTLY IS:

(1) #5 VERTICAL REBAR AT 32" O.C.

(2) #4 HORIZONTAL REBAR AT 4'-0" O.C.

8. THE TYPICAL LINTELS OVER OPENINGS IN THE WALL SHALL HAVE (2) #5 REBAR IN BOTH TOP AND

BOTTOM OF LINTEL FOR 8" WALLS & GROUTED FOR 1'-4" ABOVE OPENING.

9. THERE SHALL BE A MIN. OF (1) #4 REBAR ON ALL SIDES OF & ADJACENT TO EVERY OPENING WHICH IS LESS THAN 48" IN BOTH DIRECTIONS. WHERE THE OPENING IS 48" OR GREATER IN EITHER DIRECTION A MIN. OF (1) #5 REBAR SHALL BE USED AND SUCH REBAR SHALL EXTEND

NOT LESS THAN 24" BEYOND THE OPENING AT ALL DOOR OPENINGS/JAMBS PROVIDE

VERTICAL REINFORCEMENT REBAR FULL HEIGHT IN ALL CELLS.

10. AT CORNERS & WALL INTERSECTIONS, GROUT THE ADJACENT CORES WITH A VERTICAL REBAR

& LAP THE BOND BEAM STEEL OR PROVIDE CORNER REBAR OF EQUAL SIZE,

11. ALL DOWELS FROM THE FOUNDATION SHALL MATCH SIZE UNLESS NOTED DIFFERENTLY. EXTEND

DOWEL A MIN. OF 36 REBAR DIAMETERS INTO THE FOUNDATION.

12. VERTICAL CONTROL JOINTS SHALL BE PROVIDED IN THE WALLS AS SHOWN ON THE

ELEVATIONS.

SPECIAL INSPECTIONS:

1. THE OWNER, OR CONTRACTOR, SHALL RETAIN AN "APPROVED AGENCY," PER 2022 OREGON

STRUCTURAL SPECIALTY CODE (O.S.S.C.) . 1703 or 1704, TO PROVIDE THE SPECIAL INSPECTIONS

INDICATED BELOW FOR THIS PROJECT.

2. SPECIAL INSPECTORS SHALL BE QUALIFIED PERSONS PER I.B.C. 1704.2.1.

3. PERFORM ALL SPECIAL INSPECTIONS & TESTS IN ACCORDANCE WITH CHAPTER 17 OF THE 2022

OREGON STRUCTURAL SPECIALTY CODE(O.S.S.C.) .

4. THE FOLLOWING ITEMS REQUIRE SPECIAL INSPECTION:

a. FOUNDATION WAS DESIGNED W/ F'c = 2500 psi SPECIFICATIONS. INSPECTION NOT REQUIRED, U.N.O. (2022 O.S.S.C. 1705.3 exception 2.3).

b. MASONRY CONSTRUCTION:

5. MASONRY CONSTRUCTION SHALL BE INSPECTED AND VERIFIED IN ACCORDANCE WITH THE

REQUIREMENTS OF SECTION 1704.5.2 OF THE 2022 O.S.S.C. LEVEL 1 INSPECTION IS REQUIRED.

GENERAL CONTRACTOR SHALL NOTIFY SPECIAL INSPECTOR A MINIMUM OF 48 HOURS PRIOR TO

GROUTING OPERATIONS.

2022 O.S.S.C.

LUMBER:

1. SAWN LUMBER FOR ALL WALL STUDS SHALL BE DOUG FIR LARCH No. 2 (DF-L, #2) OR BETTER

(U.N.O.).

2. ALL LUMBER IN CONTACT W/ CONCRETE, MASONRY, OR GROUND SHALL BE PRESERVATIVE

TREATED WOOD IN ACCORDANCE W/ AWPA STANDARDS OR U.N.O.

3. AT A MINIMUM, ALL NAILING SHALL MEET THE REQUIREMENTS OF I.B.C., TABLE 2304.6.1. ALL

NAILS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE.

4. FOR CONNECTIONS OF "SIMPSON HARDWARE" OR EQUIVALENT, FOLLOW MANUFACTURES

RECOMMENDATIONS

5. MANUFACTURED TRUSSES:

a. TRUSS LOADING:

TOP CHORD D.L. = 7 psf TOP CHORD L.L. = 25 psf BOTTOM CHORD D.L. = 8 psf BOTTOM CHORD L.L. = 10 psf

b. BOTTOM CHORD LIVE LOAD DOES NOT ACT CONCURRENTLY

W/ TOP CHORD LIVE LOAD.

MASONRY BLOCK:

1. CONCRETE BLOCK SHALL BE HOLLOW, MEDIUM WEIGHT, LOAD BEARING UNITS CONFORMING TO

ASTM C55, 73, 90 AND 744 WITH A MINIMUM COMPRESSIVE STRENGTH OF 1900 PSI U.N.O.

2. ALL BLOCKS SHALL BE PLACED IN RUNNING BOND CONSTRUCTION WITH ALL VERTICAL CELLS IN

ALIGNMENT, U.N.O.

3. MORTAR: ASTM C-270, TYPE S. F'C=1500 PSI

4. NET COMPRESSIVE STRENGTH OF THE OVERALL MASONRY SYSTEM (MORTAR, BLOCK AND

GROUT) SHALL BE: F'm = 1500 PSI.

5. PROVIDE (2) #5 REBAR WITH 24" PROJECTION ON ALL SIDES OF ALL OPENINGS OR

RE-ENTRANT CORNERS IN CONCRETE.

MASONRY GROUT:

1. GROUT SHALL CONFORM TO REQUIREMENTS OF ASTM C476.

2. SUFFICIENT WATER SHALL BE USED FOR GROUT TO FLOW INTO ALL JOINTS OF THE MASONRY

WITHOUT SEGREGATION.

3. GROUT SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI AT 28 DAYS.

4. ALL CELLS IN CONCRETE BLOCK CONTAINING REINFORCING SHALL BE FILLED SOLID

WITH GROUT.

5. HOLD GROUT DOWN 11/2"BELOW TOP OF BLOCK AT GROUT LIFT JOINTS.

6. REBAR USED: .................ASTM A615, GRADE 60, WHERE WELDING IS REQUIRED USE: ASTM A705M

GRADE 60.

36' - 0" (OUT-TO-OUT OF CONCRETE)

3' - 4"

4' - 0"3' - 4"4' - 8"

12' - 0"

S5.1

CONTROL JOINTS

SEE DTL 1/S5.1

8'-6" ± C.J.

7' -8

C

.J

FLOOR

DRAIN

(TYP. OF 7)

4" CONCRETE SLAB WITH FIBER MESH

ON 2" OF SAND ON 10 MIL. VAPOR BARRIER

ON COMPACTED STRUCTURAL FILL, & ON

COMPACTED, NATIVE SOIL (NON-ORGANIC

100' -0"

12' - 0"3' - 4" 5' - 4"

3' - 4" 3' - 4"5' - 4"12' - 0"

O U

T-

TO

-O U

T O

F C

O N

C R

ET

E)

S5.1

S5.1

S5.1

S5.1

S5.1

S5.1

S5.1

S5.1

TYPE S12" HI-R-CMU WALL (2) #4 @ 48" O.C.

SHEARWALL HATCH

MORTAR TYPE#

MARK

WALL THICKNESS - BLOCK SIZE OR BLOCK TYPE

SHEAR WALL SCHEDULE

HORIZONTAL

REINFORCEMENT

VERTICAL

1 (1) #5 @ 32" O.C.

FASTENERS

DIAPHRAGM SCHEDULE

MARK

DESCRIPTION BLOCKED COMMENTS

8d @ 6" O.C. EDGES, 12" O.C. FIELD

A NO7/16" PLY/OSB, 48/24 APA RATED,H-CLIPS SEE DETAIL 13/S5.1

ATTIC VENTILATION REQUIREMENTS

912 ft.²/300 = 3.04 ft²

NOT LESS THAN 40% & NOT MORE THAN 50% OF THE REQ'D VENT AREA SHALL PROVIDED BY VENTS LOCATED IN THE UPPER PORTION OF THE ATTIC SPACE. 1.22 ft² < RIDGE VENTILATION < 1.52 ft².

L1 107' - 4" (2) #4 SEE DETAIL 7/S5.1

LINTEL SCHEDULE

MARK BOTTOM

ELEVATION

REINFORCING

COMMENTSMIN.

DEPTH

1'-4"

WIDTH

"W"

1'-0"

TOP

CENTER

(2) #4

BOTTOM

STIRRUPS

S1

SIZE

d

L2 107' - 4" (2) #4 SEE DETAIL 7/S5.1 1'-4" 1'-0" - (2) #4 8"#3 -

ROOFING NOTES

1. TRUSS MANUFACTURER SHALL DESIGN TRUSSES FOR UPLIFT & SNOW DRIFT AS APPLICABLE.

2. INSTALL ICE & WATER SHIELD 36" (MINIMUM) ALONG OUTSIDE PERIMETER OF ROOF.

A

TYP. ROOF

DIAPHRAGM

L1 L1 L1

L1 L1

L2

RIDGERIDGE

S5.1

S5.1

S5.1

S5.1

ATTIC

ACCESS

(SEE DTL

12/S5.1)

SHEET NO. ____ OF ______

JOB NO. ________________

TH

IS

D

RA

W

IN

G

IS

T

HE

S

OL

E

PR

OP

ER

TY

O

F

EN

GI

NE

ER

IN

G

NO

RT

HW

ES

T, LL

C.

A

ND

S

HA

LL

N

OT

B

E

RE

PR

OD

UC

ED

O R

US

ED

IN

A

NY

F

OR

M

OR

M

AN

NE

R, N

OR

A

RE

T

HE

Y

TO

B

E

AS

SI

GN

ED

T

O A

TH

IR

D

PA

RT

Y

W

IT

HO

UT

F

IR

ST

O

BT

AI

NI

NG

T

HE

W

RI

TT

EN

C

ON

SE

NT

O F

EN

GI

NE

ER

IN

G

NO

RT

HW

ES

T, LL

C.

A

NY

R

EP

RO

DU

CT

IO

N

IN

P

AR

T

OR

A

S A

W

HO

LE

IS

S

TR

IC

TL

Y

PR

OH

IB

IT

ED

. S

HO

UL

D

UN

AU

TH

OR

IZ

ED

R

EU

SE

O

CC

UR

, E

NG

IN

EE

RI

NG

N

OR

TH

W

ES

T, LL

C.

S

HA

LL

B

E

HE

LD

H

AR

ML

ES

S.

N ew

C on ce ss io n

R es tr oo m s:

So ut h 1s t S tre et , H er m is to n, O re go n

Kn er r C on st ru ct io n In c.

N st

S t #

2, H er m is to n, O

R

MA

RK

RE

VI

SI

ON

D

ES

CR

IP

TI

ON

DA

TE

R ev ie w ed B y:

D ra w n

By

Ap pr ov ed

B y:

Pr in t D

G S ca le

M

AR

25-016

AS

N

O

TE

D

P.

H

PA

T

W O

O D

C O

C K

DATE SEALED: _____________________04/15/2025

He rm is to n Sc ho ol

D is tr ic t

PA

T W

O O

D C

O C

K

RE

VI

SI

ON

P

ER

C

LIE

NT

R

EV

IE

W

/15

/20

4/15/2025 11:01:15 AM

FD

N

R

O O

F

FR

AM

IN

G

PL

AN

S

S4

1/4" = 1'-0"2 FOUNDATION PLAN

1/4" = 1'-0"3 ROOF FRAMING PLAN

P A T

J. WOOD

CO

C K

LA

NO

IS

SEFORPDERETSI

GER

MARCH 8, 20

HC120112

R4819

.5 .8

.2 .6

0896A160664240432

HC1201120

R48192 10.5-

.875

19.2- .625

0896A160664240432

HC120112

R4819

.5 .8

.2 .6

0896A160664240432

HC1201120

R48192 10.5-

.875

19.2- .625

0896A160664240432

HC1201120

R48192 10.5-

.875

19.2- .625

0896A160664240432

HC120112

R4819

.5 .8

.2 .6

0896A160664240432

HC1201120

R48192 10.5-

.875

19.2- .625

0896A160664240432

HC120112

R4819

.5 .8

.2 .6

0896A160664240432

IF THIS BAR SCALE DOES NOT

MEASURE 1" THEN THIS DRAWING

IS NOT TO SCALE

NOTES:

1. MAX. CONTROL JOINT SPACING IS 10'-0".

2. CONTRACTORS OPTION TO USE EITHER

SAWCUT OR FORMED KEY JOINT.

3. SAWCUT AS SOON AS POSSIBLE AFTER

POUR AND IN NO CASE SHALL IT BE MORE

THAN 12 HOURS AFTER POUR.

SAWCUT

FORMED

KEY

0' - 0 1/4"

INDUCED CRACKCONCRETE SLAB

SLAB REINFORCING

(IF APPLICABLE)

EQ

EQ

EQ

EQ

EQ

R.O. AS PER PLAN

STEMWALL & FTG

< STEMWALL PLAN >

CONC. SLAB

PER PLAN

EXTERIOR FINISH

AS PER OWNER

PER PLAN

T.O.C.

#4 BENT BAR

@ 16" O.C.

R-15 RIGID

INSUL. CONT.

T.O. CONC.

100' - 0"

T.O. FTG

98' - 0"

R-15 RIGID

INSULATION

12"x8"x16"

HI-R-H CMU WALL

REINFORCED 4" CONCRETE SLAB, ON

10 MIL. VAPOR BARRIER, ON

COMPACTED CRUSHED AGGREGATE,

SUB-GRADE & NATIVE SOIL

GRADE

6"12"6"

2' - 0"

8"

12" CONC. WALL

W/ (3) #4 CONT.

CONT. FOOTING

W/ (3) #4 REBAR

CONT. IN TRENCH

#5 VERT. DOWELS

@ 16" O.C. W/ ALT HOOK

PLAN VIEW

CMU WALL

PER PLAN

GROUTED CELL W/ #5

VERT. BAR @ WALL

INTERSECTIONS, TYP.

6d @ 6" O.C.

EA. SIDE, TYP.

1/2"∅ DRILLED

EXPANSION

ANCHOR W/

3" EMBED. @

24" O.C. VERT.

SPACING

2x STUDS, TYP.

FINISH-

PER WALL

TYPES

TYP. WALL REINF.

SEE DETAILS

CMU TO WOOD WALL DETAIL

N.T.S.11

1x4 BACKING BAND

R-49 INSULATION

1x TRIM ALL AROUND, 3/4" (MIN.)

LIP REQ.

WEATHER STRIPPING

7/16" x 8" ± O.S.B LINER

WALL (TYP. OF 4 SIDE)

3/4" SQ. NAILER @

BACK SIDE OF O.S.B.

BOT. CHORD OF MANUF.

TRUSS @ EACH SIDE

ATTIC HATCH:(2) 31/2" THICK RIDGED

FOAM BOARDS OVER 5/8" TYPE 'X'

GWB, & ALL LAMINATED TOGETHER

SECTION VIEW

22½" x 32½" R.O.

20" x 30" F.O. MIN.

AT

TI

C

3½" x 22¼" x 32¼"

3½" x 22¼" x 32¼"

30" x 22" F.O.

(FINISHED OPENING)

MANUF. TRUSS BOT. CHORD

2x H

EA

D

ER

2x H

EA

D

ER

PLAN VIEW

MANUF. TRUSS BOT. CHORD

TYP. ATTIC ACCESS DETAIL

N.T.S.12

CAULKING DETAIL

DEPTH OF

CAULKING

ONE HALF

THE WIDTH

OF THE

HEAD JOINT

WIDTH OF

HEAD JOINT

BACKER

ROD

NOTES:

1. MAX. CONTROL JOINT

SPACING = 24'-0"

COORD. W/ OWNER.

2. LEAVE BOND BEAM

CONT. AT TOP OF WALL

AND AT ALL INTERSECTING

FLOORS.

CONTROL

JOINT

3/4"∅x48" SMOOTH DOWEL

GREASE OR SLEEVE

SEE

CAULKING

DETAIL

TYP.

HORIZ.

REINF.

#4 VERT.

REINF.

CAULKING JOINT DETAIL

N.T.S.6

A

A

SE

E

LI

N

TE

L

SC

H

D

ELEVATION

(SEE PLANS)

OPENING

SECTION A-A

24"

MIN8"

LI

N

TE

L

D

EP

TH

(D

12" HI-R-H CMU WALL

TOP REINF.

SEE LINTEL SCH.

BOTTOM REINF.

SEE LINTEL SCH.

STIRRUP, TYP.

SEE LINTEL SCH.

STIRRUP, TYP.

SEE LINTEL

SCH.

(2) #4 BARS

(U.N.O.) @

BOTTOM

4 SPACES

@ 8" O.C.

LINTEL REINFORCING DETAIL

N.T.S.7

(2) #4 BARS

(U.N.O.) @ TOP

TYP. CMU WALL CORNER DETAIL

N.T.S.8

PROVIDE CORNER

& TEE JOINT

REINF. TYPICAL.

VERT. BAR

CENTERED IN

THESE

CELLS

2' -6

2'-6"

2' -6

2'-6"

#5 VERT. BAR @

32" O.C. CENTERED

IN CELL

#5 VERT. BAR

@ 32" O.C.

CENTERED IN

CELL

(2) VERT. BARS

CENTERED IN

THESE CELLS

PROVIDE 180°

HOOKS

@ OPENINGS,

TYPICAL

OPENING

SEE PLN.

CMU WALL OPENING DETAIL

N.T.S.9

REINFORCED CONCRETE

SLAB FLOOR AS PER

PLAN

#4 VERTICAL DOWELS

PROJECTED 24" A.F.F.

CMU WALL REINF'D W/ #5 VERT.

BARS @ 32" O.C. FULL HEIGHT

TIE PARALLEL BARS TOGETHER

W/ (3)

16.5 GAUGE WIRE TIES (TYP.)

CMU BLOCK

AS PER PLAN &

ELEVATION

CMU BOND BEAM

COARSE @ 48" O.C. REINF'D

W/ (2) #4 HORIZ. BARS (TYP.)

REINFORCED CONC.

APRON AS PER

PLAN

CMU WALL REINF. DETAIL

N.T.S.10

16" EAVE

5/8" GYPSUM BD

5/8" DIA. A.B. W/ 7" MIN.

EMBEDMENT @ 24" O.C.

28 GA MTL ROOFING ON

MOISTURE BARRIER ON

7/16" O.S.B. ON MFG TRUSSES

METAL FLASHING

ON 2x6 SUB-FASCIA

VENTED SOFFIT

BOARD & BATT

SIDING (OR A.P.O.)

12"x8"x16"

HI-R-H CMU WALL

SIMPSON H1A

HURRICANE TIE

SIMPSON LU24

HANGER

T.O. CMU WALL

108'-8"

VENTED

SOFFIT

24" EAVE

5/8" GYPSUM BD

12"x8"x16"

HI-R-H CMU WALL

28 GA MTL ROOFING ON

MOISTURE BARRIER ON

7/16" O.S.B. ON MFG TRUSSES

METAL DRIP EDGE ON

2x6 SUB-FASCIA

INSUL.

BAFFLE

SIMPSON H1

HURRICANE TIE

5/8" DIA. A.B. W/ 7" MIN.

EMBEDMENT @ 24" O.C.

H

EE

L

8"

PLAN VIEW

N.T.S

NAILING TO INTERMEDIATE FRAMING

MEMBERS IS ALSO KNOWN AS "FIELD"

NAILING. MAX SPACING IS 12" O.C.

FOR ROOFS AND FLOORS.

MAX NAIL SPACING

AT DIAPHRAGM

BOUNDARY AND

SUPPORTED EDGES

IS 6" O.C.

4'x8' PLY OR

OSB PANEL

DIAPHRAGM

BOUNDARY

PLYWOOD EDGE

NAILING

THIS PANEL JOINT

NOT CONTINUOUS

CONTINUOUS

PANEL JOINT

FLOOR OR ROOF

FRAMING

THIS PANEL EDGE IS

NOT SUPPORTED BY

BLOCKING AND IS

KNOWN AS THE

UNBLOCKED EDGE -

OTHER TYPE OF

EDGE SUPPORT MAY

BE REQUIRED

SHEET NO. ____ OF ______

JOB NO. ________________

TH

IS

D

RA

W

IN

G

IS

T

HE

S

OL

E

PR

OP

ER

TY

O

F

EN

GI

NE

ER

IN

G

NO

RT

HW

ES

T, LL

C.

A

ND

S

HA

LL

N

OT

B

E

RE

PR

OD

UC

ED

O R

US

ED

IN

A

NY

F

OR

M

OR

M

AN

NE

R, N

OR

A

RE

T

HE

Y

TO

B

E

AS

SI

GN

ED

T

O A

TH

IR

D

PA

RT

Y

W

IT

HO

UT

F

IR

ST

O

BT

AI

NI

NG

T

HE

W

RI

TT

EN

C

ON

SE

NT

O F

EN

GI

NE

ER

IN

G

NO

RT

HW

ES

T, LL

C.

A

NY

R

EP

RO

DU

CT

IO

N

IN

P

AR

T

OR

A

S A

W

HO

LE

IS

S

TR

IC

TL

Y

PR

OH

IB

IT

ED

. S

HO

UL

D

UN

AU

TH

OR

IZ

ED

R

EU

SE

O

CC

UR

, E

NG

IN

EE

RI

NG

N

OR

TH

W

ES

T, LL

C.

S

HA

LL

B

E

HE

LD

H

AR

ML

ES

S.

N ew

C on ce ss io n

R es tr oo m s:

So ut h 1s t S tre et , H er m is to n, O re go n

Kn er r C on st ru ct io n In c.

N st

S t #

2, H er m is to n, O

R

MA

RK

RE

VI

SI

ON

D

ES

CR

IP

TI

ON

DA

TE

R ev ie w ed B y:

D ra w n

By

Ap pr ov ed

B y:

Pr in t D

G S ca le

M

AR

25-016

AS

N

O

TE

D

P.

H

PA

T

W O

O D

C O

C K

DATE SEALED: _____________________04/15/2025

He rm is to n Sc ho ol

D is tr ic t

PA

T W

O O

D C

O C

K

RE

VI

SI

ON

P

ER

C

LIE

NT

R

EV

IE

W

/15

/20

4/15/2025 11:01:16 AM

ST

RU

CT

U

RA

L

DE

TA

IL

S

S5.1

N.T.S.1 CONTROL JOINT DETAILS

1" = 1'-0"2 OVERLAPPING DETAIL@ SHOP

1" = 1'-0"3 FOUNDATION DETAIL 1

1" = 1'-0"5 GABLE EAVE DETAIL

1" = 1'-0"4 TRUSS TO CMU

N.T.S.13 ROOF DIAPHRAGM DETAIL

File details come from the government source that posted it. Updated .