Fire Protection Drawing.pdf

PDF 2 MB Posted

Attached to
Y1DA--Renovate for Patient Privacy - Wing J (VA-20-00044784)
Solicitation number
36C24620R0119
Issued by

About this file

This document package includes architectural drawings and specifications for renovations to Patient Wing J at the Department of Veterans Affairs Medical Center in Salem, Virginia. The project involves demolishing existing walls and ceilings, and constructing new patient rooms, bathrooms, offices, and support spaces. Key project details include installing new fire alarm, fire suppression, flooring, casework, and equipment. The scope of work affects Zones 4-2 and 4-3 of the existing sprinkler system. The contract opportunity is solicitation number 36C24620R0119 for project number 658-18-101 to upgrade patient privacy in Wing J, issued by the VA Veterans Health Administration VISN 6. The package provides plans, schedules, sections, and 3D renderings of the proposed renovations.

View the file

Other files

File Type Posted
36C24620R0119 0005_1.docx DOCX document
36C24620R0119 0005.pdf PDF
36C24620R0119 0004.pdf PDF
36C24620R0119 0004_1.docx DOCX document
36C24620R0119 0003.pdf PDF
36C24620R0119 0003_1.docx DOCX document
102800-Toilet Bath and Laundry Accessories.pdf PDF
36C24620R0119 0002_1.docx DOCX document
S02 RFI Questions.pdf PDF
20180509R1 BES-SVAMC Bldg. 143 4th Floor Limited Hazardous Materials Survey Report.pdf PDF
S06 36C24620R0119 0002.pdf PDF
36C24620R0119 0001_1.docx DOCX document
S04 Site Visit sign-in for Renovate Patient Privacy 8-5-2020.pdf PDF
PROPOSAL ITEM LIST 8-7-2020.pdf PDF
Plumbing B Drawing.pdf PDF
Plumbing C Drawing.pdf PDF
Plumbing E Drawing.pdf PDF
Mechanical Drawing.pdf PDF
Structural Drawing.pdf PDF
Plumbing A Drawing.pdf PDF
Plumbing D Drawing.pdf PDF
S02 36C24620R0119.pdf PDF
Interior Design Drawing.pdf PDF
Equipment Drawing.pdf PDF
Electrical A Drawing.pdf PDF
General Drawing.pdf PDF
658-18-101_SPECS.pdf PDF
Electrical B Drawing.pdf PDF
36C24620R0119_2.docx DOCX document
VA20200172 05-29-2020 Wage Determination.pdf PDF
Architectural Drawing.pdf PDF
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

E

F

G

H

I

J

K

L

7 8 9 10 11 13 8.2

6 12

H.6

MATCH LINE

OFFICE

NURSE MGR

4J-108

MEDICATION

4J-121

EQUIPMENT

STORAGE

4J-109

EQUIPMENT

STORAGE

4J-117

ELECTRICAL

CLOSET

4J-119

IRM

TELEPHONE

4J-106

STAFF TOILET

4J-104

EQUIP

STORAGE

4J-122A

STAFF

LOUNGE

4J-120

DIRTY UTILITY

/ OXYGEN

STORAGE

4J-132

KITCHEN

4J-122B

BPO

4J-138

CLEAN

SUPPLY

4J-122

BATH RM

4J-150A

ON CALL

4J-150

ON CALL

4J-151

BATH RM

4J-142B

ANTE RM

4J-142A

SOCIAL

WORKER

4J-143

BATH RM

4J-141A

BATH RM

4J-139A

BATH RM

4J-136A

PATIENT RM

4J-137

BATH RM

4J-131A

EQUIPMENT

STORAGE

4J-133

GENERAL

STORAGE

4J-127

WHCH BATH

RM

4J-125A

BATH RM

4J-123A

MECH SHAFT

4J-M2

PATIENT RM

4J-114

WHCH BATH

RM

4J-112A

BATH RM

4J-110A

BATH RM

4J-107A

WORK RM

4J-102

MENS

TOILETS

4J-100

WOMENS

TOILET

4J-101

WAITING /

DAY RM

4J-103

PATIENT RM

4J-124

OFFICE

4J-110

PATIENT RM

4J-107

ISOLATION -

PATIENT RM

4J-105

STAIR

S-2

HOUSE

KEEPING

4J-153

ELEVATOR

E-1

ELEVATOR

E-2

ELEVATOR

E-3

SOILED LINEN

4J-155

TRASH

4J-154

ELEVATOR

E-6

ELEVATOR

E-4

ELEVATOR

E-5

ELECTRICAL

4J-156

MALE

LOCKER

4J-146A

FEMALE

LOCKER

4J-146C

BATH RM

4J-146B

LOCKER

4J-147

CONFERENCE

RM

4J-148

STORAGE

4J-148A

FEMALE

TOILET

4J-146D

S ELEVATOR

LOBBY

CJ4-11

LOUNGE

4J-146

PATIENT RM

4J-139

MECH CHILL

4J-145

PATIENT RM

4J-136

PATIENT RM

4J-134

WHCH BATH

RM

4J-134A

PATIENT RM

4J-135

CLEAN LINEN

4J-130

BATH RM

4J-128A

BATH RM

4J-129A

PATIENT RM

4J-129

PATIENT RM

4J-126

PATIENT RM

4J-125

BATH RM

4J-151A

OFFICE

4J-152

DUMP

WAITER 2

4J-D2

BATH RM

4J-105B

PATIENT RM

4J-112

PATIENT RM

4J-113

HAC

4J-116

BATH RM

4J-114A

STAIR

S-1

MECH

RM/SVC BAY

4J-118

CORRIDOR

CJ4-5

ISOLATION

RM

4J-142

PATIENT RM

4J-141

PATIENT RM

4J-131

PATIENT RM

4J-128

PATIENT RM

4J-123

PATIENT RM

4J-115

CORRIDOR

CJ4-13

CORRIDOR

CJ4-1

NURSE

STATION

CJ4-8

CORRIDOR

CJ4-9

CORRIDOR

CJ4-10

NURSE

STATION

CJ4-4

CORRIDOR

CJ4-12

DIETITIAN

4J-144

EQUIPMENT

STORAGE

4J-111

CORRIDOR

CJ4-6

CORRIDOR

CJ4-7

NURSE

STATION

CJ4-4A

NURSE

STATION

CJ4-4B

VIS LOUNGE

CJ4-2

CORRIDOR

CJ4-3

ANTE RM

4J-105A

HEALTH CARE SLEEPING DEPARTMENT

FULLY SPRINKLERED

SP SP

SP

SP

SPSP

SP

SP

SP

SSSS

SS SS

SS

SS

SS

M

M

AI AI

VTWF

DSS

DSS

AR

M

CEILING MOUNTED FIRE ALARM SPEAKER/STROBE

DEVICE KEY

CEILING MOUNTED FIRE ALARM SPEAKER

FIRE ALARM SPEAKER/STROBE

LEGEND

ALARM PRESSURE SWITCH

MANUAL FIRE ALARM BOX

HEAT DETECTOR

SMOKE DETECTOR

FIRE ALARM LIGHT

WATERFLOW SWITCH

MINIMUM CANDELA RATING

(NOTIFICATION APPLIANCES ONLY)

CEILING MOUNTED FIRE ALARM STROBE

N - NEW DEVICE

ED - EXISTING TO BE DELETED

ER - EXISTING TO BE REPLACED

E - EXISTING TO BE RE-USED

L - LOCAL SYSTEM-DO NOT MODIFY

WF

APS

M

SP

SS

L

FIRE ALARM STROBE

N(30)

VALVE TAMPER SWITCH

VT

AR

DSS

DUCT SMOKE DETECTOR SUPPLY

ADDRESSABLE RELAY MODULE

INDICATES EXISTING AREA

OUTSIDE OF PROJECT WORK AREA.

AI

ADDRESSABLE INTERFACE MODULE

EXISTING FIRE ALARM ZONE BOUNDARY

FAD101

1/8" = 1'-0"

FIRE ALARM DEMOLITION PLAN - ZONE J

FIRE ALARM DEMOLITION PLAN

SCALE: 1/8" = 1'-0"

0 4' 8' 16'

GENERAL NOTES

1. THE AREAS OF WORK FOR MODIFICATIONS TO THE FIRE ALARM

SYSTEM ARE INDICATED ON THIS SHEET.

2. EXISTING SUSPENDED CEILING SYSTEMS THROUGHOUT THE AREA

OF WORK WILL BE REMOVED AND REPLACED. EXISTING CEILING

MOUNTED DEVICES AND APPLIANCES SHALL BE REMOVED OR

TEMPORARILY RELOCATED AS NOTED TO ACCOMMODATE REMOVAL

OF SUSPENDED CEILING SYSTEMS.

3. ALL INITIATING DEVICES AND NOTIFICATION APPLIANCES NOT

INDICATED FOR REMOVAL SHALL BE MAINTAINED IN-SERVICE.

COORDINATE TEMPORARY IMPAIRMENTS WITH THE GENERAL

CONTRACTOR.

4. REFER TO DRAWING FA101 FOR THE NEW LAYOUT FOR EXISTING (TO

REMAIN) AND NEW DEVICES AND APPLIANCES.

5. EXISTING CONDUIT SYSTEMS MAY BE REUSED TO ACCOMMODATE

THE NEW FIRE ALARM SYSTEM LAYOUT SHOWN ON DRAWING FA101.

6. THE SCOPE OF THIS PROJECT INCLUDES DEMOLITION AND

REPLACEMENT OF THE ZONE J AUTOMATIC SPRINKLER PIPING

SYSTEM. THE FIRE ALARM CONTRACTOR SHALL INSTALL TEMPORARY

AREA HEAT DETECTION MONITORED BY THE BUILDING FIRE ALARM

SYSTEM THROUGHOUT THE DEMOLITION AREA DURING THE PERIOD

OF IMPAIRMENT TO THE SPRINKLER SYSTEM. COORDINATE THE

IMPAIRMENT PERIOD WITH THE GENERAL CONTRACTOR.

7. ALL MODIFICATIONS TO THE FIRE ALARM SYSTEM SHALL BE IN

ACCORDANCE WITH NFPA 72, NATIONAL FIRE ALARM CODE, 2016

EDITION AND SPECIFICATION 28 31 00.

KEYED NOTES

TEMPORARILY REMOVE EXISTING SMOKE DETECTOR AND REINSTALL IN

NEW CEILING.

KEY PLAN

PLAN

NORTH

J o n e e i g h t h i n c o e f o t t h r e e i n c h e s o t o n e a d a l f i n c h e o t o n e i n o t t h r e e q u a r t e r s i n o t o n e h a l f i n o t t h r e e e i g h t h s i n o t o n e q u a r t e r i n o t

VA FORM 08-6231, OCT 1978

A

123456789

123456789

B

C

D

E

F

A

B

C

D

E

F

Drawing Title Project Title

CheckedBuilding Number Drawn

Date

Project No.

Drawing No.

Location

REVISED CONSTRUCTION DOCUMENTS

V e t e r a n s

A f f a i r s

Approved: Associate Director

Approved: Chief of Staff

Approved: Service Chief

Approved: GEMS Coordinator

Approved: Infection Control Officer

Approved: Safety Manager

Approved: Chief of Mental Health Service

Approved: Chief of Police

Approved: Energy Engineer

Approved: Patient Safety Nurse

Approved: Chief of Facility Management Svc.

Approved: Medical Center Director

A

M

Sheet of

DESIGN/BUILD

VAMC SALEM, VIRGINIA

658-18-101

02/28/2019

90Revisions: Date:

RENOVATE FOR PATIENT

PRIVACY - ZONE J

Corporate Office:

766 Middle St, Fairhope, AL 36532

Phone: 251.990.5778

Fax: 251.990.3716

J UPGRADES 12-4-2019

SRMJAS

12/04/2019

ZONE

HEALTH CARE SLEEPING DEPARTMENT

FULLY SPRINKLERED

MENS

TOILETS (NIC)

WOMENS

TOILET (NIC)

HOUSE

ELEVATOR

SOILED LINEN

(NIC)

TRASH (NIC)

ELEVATOR

(NIC)

ELEVATOR

(NIC)

TEAM

SHARED

CONSULT #2

/FLEX

MECH CHILL

(NIC)

BATH RM

(NIC)

SOCIAL

WORKERS

WORKSTATION

(2 STATIONS)

CORRIDOR

(NIC)

CORRIDOR

(NIC)

BATH RM

(NIC)

ON CALL (NIC)

WAITING (NIC)

CORRIDOR

(NIC)

GENERAL

STORAGE

(NIC)

ON CALL (NIC)

CONFERENCE

RM (NIC)

FLEX OFFICE

ELEVATOR

(NIC)

CORRIDOR

(NIC)

E-1

S ELEVATOR

LOBBY (NIC)

C4-11

BATH RM

POSITIVE

ISOLATION

RM

4J-107

NURSE

STATION

CJ4-4

EXIST MECH

RM/SVC BAY

4J-118

EXIST ELECT

4J-119

STAIR (NIC)

S-1

BATH RM

4J-113A

BATH RM

4J-112A

PATIENT RM

4J-112

PATIENT RM

4J-111

PATIENT RM

4J-110

ANTE RM

4J-105A

NEGATIVE

BARIATRIC

RM

4J-105

SOCIAL

WORKERS

WORKSTATION

4J-103

PATIENT RM

4J-113

EXIST HKPG

4J-116

BATH RM

4J-142B

STORAGE 1

4J-114

PATIENT RM

4J-115

BATH RM

4J-115A

BATH RM

4J-123A

PATIENT RM

4J-128

BATH RM

4J-126A

PATIENT RM

4J-126

PATIENT RM

4J-125

BATH RM

4J-125A

BATH RM

4J-128A

BATH RM

4J-131A

BATH RM

4J-135A

BATH RM

4J-134A

PATIENT RM

4J-134

BATH RM

4J-136A

PATIENT RM

4J-137

BATH RM

4J-137A

BATH RM

4J-139A

PATIENT RM

4J-139

PATIENT RM

4J-131

BATH RM

4J-130A

BARIATRIC

RM

4J-130

BATH RM

4J-105B

PATIENT RM

4J-136

PATIENT RM

4J-129

BATH RM

4J-129A

CART /

STRETCHER

ALCOVE

4J-124

PATIENT RM

4J-135

CORRIDOR

CJ4-3B

CORRIDOR

CJ4-7

CORRIDOR

CJ4-9

CORRIDOR

CJ4-6

NURSE

STATION

CJ4-8B

SUPPLY

STORAGE

4J-141

LOUNGE

4J-121

LOCKERS

4J-121B

TLT 1

4J-120A

TLT 2

4J-120B

T E

L E

M

J

ASST NURSE

MANAGER

4J-108

NURSE

MANAGER

4J-109

NOURISH

4J-120

NUTRITIONIST

OFFICE

4J-117

CRASH

MOBILE

CARTS X-RAY

4J-140

LINEN

4J-104

MED GAS

4J-122

EX. IT

4J-106

HALLWAY

CJ4-5

CORRIDOR

CJ4-10

NURSE

STATION

CJ4-8C

NURSE

STATION

CJ4-8A

L I M

I T

S

O

F

C O

N S

T R

U C

T I O

N

STORAGE 3

4J-144

NEGATIVE

ISOLATION

RM

4J-142

PHARMACIST

OFFICE

4J-160

OMNI

4J-143

UTILITY

SOILED

4J-133

UTILITY

CLEAN

4J-132

STORAGE 2

4J-127B

LINEN

4J-159

OMNI

4J-114B

STORAGE 4

4J-145

ANTE RM

4J-107A

BATH RM

4J-107B

BATH RM

4J-111A

MECH SHAFT

4J-M1

PATIENT RM

4J-123

ANTE RM

4J-142A

STOR. 5

4J-127A

1HR1HR1HR

H

R

H

R

H R

H

R

H R

H

R

H R

2HR2HR

H

R

H R

H

R

H R

H

R

H R

2HR 2HR 2HR

H

R

H R

H

R

H R

H

R

H R

H

R

H R

2HR2HR2HR

H

R

H R

H

R

H R

H

R

H R

H

R

H R

2HR 2HR 2HR

H

R

H R

2HR2HR2HR2HR2HR2HR2HR2HR2HR

H

R

H R

2HR 2HR 2HR 2HR 2HR 2HR 2HR 2HR 2HR

H

R

S P

S P

SP

S P

S P

SP

S P

S P

S P

SP SP

S P

S P

S P

SPSP

F

S B

F

S B

F

S B

F

S B

F

S B

1FSB 1FSB

1FSB 1FSB

F

S

B

F

S

B

F

S

B

F

S B

F

S B

F

S B

F

S B

H

R

2HR 2HR 2HR 2HR 2HR

H

R

H

R

H R

2HR2HR2HR2HR2HR2HR

H

R H

R

2HR 2HR 2HR 2HR 2HR 2HR

SPSP

S P

SP SP

S P

1HR1HR1HR1HR

H

R

H R

H

R

1HR 1HR 1HR 1HR 1HR

H

R

H R

H

R

SP SP

S P

S P

SPSP

S P

S P

H

R

2HR

H

R

2HR

1HR1HR1HR

H

R

H R

H

R

1HR 1HR 1HR

H

R

H R

H

R

1HR 1HR 1HR 1HR

H

R

1HR1HR1HR1HR

SS

SS

SP

SP

SP

SP

SS

SS

SS

SS

M

M

AR

DSS

FA101

1/8" = 1'-0"

FIRE ALARM PLAN - WING J

FIRE ALARM PLAN

SCALE: 1/8" = 1'-0"

0 4' 8' 16'

GENERAL NOTES

1. THIS DRAWING INDICATES GENERAL LAYOUT FOR NEW AND EXISTING

FIRE ALARM DEVICES AND APPLIANCES. THE CONTRACTOR SHALL BE

RESPONSIBLE FOR DETERMINING EXACT LOCATIONS.

2. EXISTING CIRCUITRY AND CONDUIT SYSTEMS SHALL BE MODIFIED FOR

A COMPLETE OPERATING SYSTEM. ALL FIRE ALARM CIRCUITRY SHALL

BE INSTALLED IN CONDUIT.

3. ALL NEW FIRE ALARM STROBES SHALL BE RATED AT THE CANDELLA

NOTED.

4. ALL NEW FIRE ALARM SPEAKERS SHALL BE TAPPED AT 1/2 WATT

UNLESS NOTED OTHERWISE.

5. ALL MODIFICATIONS TO THE FIRE ALARM SYSTEM SHALL BE IN

ACCORDANCE WITH NFPA 72, NATIONAL FIRE ALARM CODE, 2019

EDITION AND SPECIFICATION 28 31 00.

KEYED NOTES

NEW SUPPLY DUCT SMOKE DETECTION AND SHUTDOWN CONTROL FOR NEW

AIR HANDLER AHU J-1. INSTALL CONTROL RELAY WITHIN 36 INCHES OF UNIT

CONTROLLER.

AREA SMOKE DETECTION FOR STORAGE OPEN TO CORRIDOR.

INSTALL NEW SMOKE DETECTOR FOR DOOR RELEASE FUNCTION. PROGRAM

FOR EXISTING DOOR RELEASE ARRANGEMENT. RE-USE EXISTING RELEASING

CONTROL DEVICES AND DOOR MAGNETS.

MANUAL PULL STATION SHALL BE LOCATED AT 48 INCHES ABOVE FINISHED

FLOOR.

LOCATION OF EXISTING DISTRIBUTED POWER SUPPLY NAC 13. NAC 13 SERVES

ALL EXISTING VISIBLE NOTIFICATION APPLIANCE CIRCUITS LOCATED ON THIS

FLOOR.

o n e e i g h o t t h r e e i n c h e o t o n e a l f i n c h e o t o n e i n o t t h r e e q u a r t e r s i n o t o n e h a l f i n o t t h r e e e i g h t h s i n o t o n e q u a r t e r i n o t

VA FORM 08-6231, OCT 1978

A

123456789

123456789

B

C

D

E

F

A

B

C

D

E

F

Drawing Title Project Title

CheckedBuilding Number Drawn

Date

Project No.

Drawing No.

Location

REVISED CONSTRUCTION DOCUMENTS

V e t e r a n s

A f f a i r s

Approved: Associate Director

Approved: Chief of Staff

Approved: Service Chief

Approved: GEMS Coordinator

Approved: Infection Control Officer

Approved: Safety Manager

Approved: Chief of Mental Health Service

Approved: Chief of Police

Approved: Energy Engineer

Approved: Patient Safety Nurse

Approved: Chief of Facility Management Svc.

Approved: Medical Center Director

A

M

Sheet of

DESIGN/BUILD

VAMC SALEM, VIRGINIA

658-18-101

02/28/2019

90Revisions: Date:

RENOVATE FOR PATIENT

PRIVACY - ZONE J

Corporate Office:

766 Middle St, Fairhope, AL 36532

Phone: 251.990.5778

Fax: 251.990.3716

J UPGRADES 12-4-2019

CEILING MOUNTED FIRE ALARM SPEAKER/STROBE

DEVICE KEY

CEILING MOUNTED FIRE ALARM SPEAKER

FIRE ALARM SPEAKER/STROBE

LEGEND

ALARM PRESSURE SWITCH

MANUAL FIRE ALARM BOX

HEAT DETECTOR

SMOKE DETECTOR

FIRE ALARM LIGHT

WATERFLOW SWITCH

MINIMUM CANDELA RATING

(NOTIFICATION APPLIANCES ONLY)

CEILING MOUNTED FIRE ALARM STROBE

N - NEW DEVICE

ED - EXISTING TO BE DELETED

ER - EXISTING TO BE REPLACED

E - EXISTING TO BE RE-USED

L - LOCAL SYSTEM-DO NOT MODIFY

WF

APS

M

SP

SS

L

FIRE ALARM STROBE

N(30)

VALVE TAMPER SWITCH

VT

AR

DSS

DUCT SMOKE DETECTOR SUPPLY

ADDRESSABLE RELAY MODULE

INDICATES EXISTING AREA

OUTSIDE OF PROJECT WORK AREA.

AI

ADDRESSABLE INTERFACE MOSUDLE

2 HOUR FIRE RATED BARRIER

2HR 2HR

1HR 1HR

1 HOUR FIRE RATED BARRIER

SP SP

SMOKE PARTITION

1FSB 1FSB

1 HOUR FIRE RATED SMOKE BARRIER

NEW FIRE ALARM ZONE BOUNDARY

KEY PLAN

PLAN

NORTH

J

SRMJAS

E

F

G

H

I

J

K

L

7 8 9 10 11 13 8.2

6 12

H.6

OFFICE

NURSE MGR

4J-108

MEDICATION

4J-121

EQUIPMENT

STORAGE

4J-109

EQUIPMENT

STORAGE

4J-117

ELECTRICAL

CLOSET

4J-119

IRM

TELEPHONE

4J-106

STAFF TOILET

4J-104

EQUIP

STORAGE

4J-122A

STAFF

LOUNGE

4J-120

DIRTY UTILITY

/ OXYGEN

STORAGE

4J-132

KITCHEN

4J-122B

BPO

4J-138

CLEAN

SUPPLY

4J-122

BATH RM

4J-150A

ON CALL

4J-150

ON CALL

4J-151

BATH RM

4J-142B

ANTE RM

4J-142A

SOCIAL

WORKER

4J-143

BATH RM

4J-141A

BATH RM

4J-139A

BATH RM

4J-136A

PATIENT RM

4J-137

BATH RM

4J-131A

EQUIPMENT

STORAGE

4J-133

GENERAL

STORAGE

4J-127

WHCH BATH

RM

4J-125A

BATH RM

4J-123A

MECH SHAFT

4J-M2

PATIENT RM

4J-114

WHCH BATH

RM

4J-112A

BATH RM

4J-110A

BATH RM

4J-107A

WORK RM

4J-102

MENS

TOILETS

4J-100

WOMENS

TOILET

4J-101

WAITING /

DAY RM

4J-103

PATIENT RM

4J-124

OFFICE

4J-110

PATIENT RM

4J-107

ISOLATION -

PATIENT RM

4J-105

STAIR

S-2

HOUSE

KEEPING

4J-153

ELEVATOR

E-1

ELEVATOR

E-2

ELEVATOR

E-3

SOILED LINEN

4J-155

TRASH

4J-154

ELEVATOR

E-6

ELEVATOR

E-4

ELEVATOR

E-5

ELECTRICAL

4J-156

MALE

LOCKER

4J-146A

FEMALE

LOCKER

4J-146C

BATH RM

4J-146B

LOCKER

4J-147

CONFERENCE

RM

4J-148

STORAGE

4J-148A

FEMALE

TOILET

4J-146D

S ELEVATOR

LOBBY

CJ4-11

LOUNGE

4J-146

PATIENT RM

4J-139

MECH CHILL

4J-145

PATIENT RM

4J-136

PATIENT RM

4J-134

WHCH BATH

RM

4J-134A

PATIENT RM

4J-135

CLEAN LINEN

4J-130

BATH RM

4J-128A

BATH RM

4J-129A

PATIENT RM

4J-129

PATIENT RM

4J-126

PATIENT RM

4J-125

BATH RM

4J-151A

OFFICE

4J-152

DUMP

WAITER 2

4J-D2

BATH RM

4J-105B

PATIENT RM

4J-112

PATIENT RM

4J-113

HAC

4J-116

BATH RM

4J-114A

STAIR

S-1

MECH

RM/SVC BAY

4J-118

CORRIDOR

CJ4-5

ISOLATION

RM

4J-142

PATIENT RM

4J-141

PATIENT RM

4J-131

PATIENT RM

4J-128

PATIENT RM

4J-123

PATIENT RM

4J-115

CORRIDOR

CJ4-13

CORRIDOR

CJ4-1

NURSE

STATION

CJ4-8

CORRIDOR

CJ4-9

CORRIDOR

CJ4-10

NURSE

STATION

CJ4-4

CORRIDOR

CJ4-12

DIETITIAN

4J-144

EQUIPMENT

STORAGE

4J-111

CORRIDOR

CJ4-6

CORRIDOR

CJ4-7

NURSE

STATION

CJ4-4A

NURSE

STATION

CJ4-4B

VIS LOUNGE

CJ4-2

CORRIDOR

CJ4-3

ANTE RM

4J-105A

HEALTH CARE SLEEPING DEPARTMENT

FULLY SPRINKLERED

EXISTING ZONE J (4-3)

SPRINKLER VALVE STATION

2"

2"

2" 2"

2" 2"

ZONE 4-2

ZONE 4-3

2 2 2 2 2

2 2 2 2

WF

VT

EXISTING ZONE (4-2) SPRINKLER VALVE STATION

LEGEND

EXISTING SUPPRESSION PIPING

SPRINKLER SYSTEM BOUNDARY

INDICATES EXISTING AREA OUTSIDE OF

PROJECT WORK AREA.

WF

WATERFLOW SWITCH

VT

VALVE TAMPER SWITCH

EXISTING SUPPRESSION PIPING TO BE REMOVED

FXD101

1/8" = 1'-0"

FIRE SUPPRESSION DEMOLITION PLAN - ZONE J (4-3)

FIRE SUPPRESSION

DEMOLITION PLAN

SCALE: 1/8" = 1'-0"

0 4' 8' 16'

KEYED NOTES

ZONE 4-2. REMOVE EXISTING SPRINKLER AND BRANCH LINE BACK TO CROSS

MAIN. INSTALL THREADED PLUG.

LOCATION OF EXISTING SPRINKLER CONNECTED TO CROSS MAIN TO BE

REMOVED.

GENERAL NOTES

1. THE AREA OF WORK FOR MODIFICATIONS TO THE EXISTING SPRINKLER SYSTEM ARE

INDICATED ON THIS SHEET. THE EXISTING SUSPENDED CEILING SYSTEMS THROUGHOUT THE

AREA OF WORK WILL BE REMOVED AND REPLACED WITH A NEW CEILING SYSTEM.

2. THE LOCATIONS OF SPRINKLER SYSTEM CONTROL VALVES SUPPLYING SPRINKLER ZONES

ARE INDICATED.

3. EXISTING SPRINKLER BRANCH LINES, SPRINKLERS AND ASSOCIATED HANGERS SHALL BE

REMOVED AS INDICATED. THE LOCATION AND SIZE OF ALL PIPING INDICATED TO BE REUSED

SHALL BE FILED VERIFIED BY THE CONTRACTOR.

4. REFER TO DRAWING FX101 FOR THE CONFIGURATION OF NEW ROOMS THROUGHOUT THE

AREA OF WORK.

5. THE CONTRACTOR SHALL CONNECT NEW SPRINKLER BRANCH LINES TO THE EXISTING CROSS

MAIN OUTLETS, OR MODIFY EXISTING SPRINKLER CROSS MAINS, AND INSTALL NEW CEILING

PENDENT SPRINKLER PROTECTION FOR THE NEW ROOM CONFIGURATIONS.

KEY PLAN

PLAN

NORTH

J o n e e i g h o t t h r e e i n c h e o t o n e a l f i n c h e o t o n e i n o t t h r e e q u a r t e r s i n o t o n e h a l f i n o t t h r e e e i g h t h s i n o t o n e q u a r t e r i n o t

VA FORM 08-6231, OCT 1978

A

123456789

123456789

B

C

D

E

F

A

B

C

D

E

F

Drawing Title Project Title

CheckedBuilding Number Drawn

Date

Project No.

Drawing No.

Location

REVISED CONSTRUCTION DOCUMENTS

V e t e r a n s

A f f a i r s

Approved: Associate Director

Approved: Chief of Staff

Approved: Service Chief

Approved: GEMS Coordinator

Approved: Infection Control Officer

Approved: Safety Manager

Approved: Chief of Mental Health Service

Approved: Chief of Police

Approved: Energy Engineer

Approved: Patient Safety Nurse

Approved: Chief of Facility Management Svc.

Approved: Medical Center Director

A

M

Sheet of

DESIGN/BUILD

VAMC SALEM, VIRGINIA

658-18-101

02/28/2019

90Revisions: Date:

RENOVATE FOR PATIENT

PRIVACY - ZONE J

Corporate Office:

766 Middle St, Fairhope, AL 36532

Phone: 251.990.5778

Fax: 251.990.3716

J UPGRADES 12-4-2019

SRMJAS

MENS

TOILETS (NIC)

WOMENS

TOILET (NIC)

HOUSE

ELEVATOR

SOILED LINEN

(NIC)

TRASH (NIC)

ELEVATOR

(NIC)

ELEVATOR

(NIC)

TEAM

SHARED

CONSULT #2

/FLEX

MECH CHILL

(NIC)

BATH RM

(NIC)

SOCIAL

WORKERS

WORKSTATION

(2 STATIONS)

CORRIDOR

(NIC)

CORRIDOR

(NIC)

BATH RM

(NIC)

ON CALL (NIC)

WAITING (NIC)

CORRIDOR

(NIC)

GENERAL

STORAGE

(NIC)

ON CALL (NIC)

CONFERENCE

RM (NIC)

FLEX OFFICE

ELEVATOR

(NIC)

CORRIDOR

(NIC)

E-1

S ELEVATOR

LOBBY (NIC)

C4-11

BATH RM

E

F

G

H

I

J

K

L

7 8 9 10 11 13 8.2

6 12

H.6

L I M

I T

S

O

F

C O

N S

T R

U C

T I O

N

1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR

H

R

H R

H

R

H R

1HR1HR1HR1HR1HR1HR1HR1HR1HR

HEALTH CARE SLEEPING DEPARTMENT

FULLY SPRINKLERED

EXISTING ZONE J SPRINKLER

VALVE STATION

OHI

OHIOHIOHI

OHI

OHI

OHI

OHI

ZONE 4-2

ZONE 4-3

1HR1HR1HR1HR1HR1HR

H

R

H R

H

R H

R H

R

H R

2HR2HR2HR2HR2HR2HR2HR2HR2HR2HR2HR2HR

H

R

H R

H

R

H R

2HR 2HR 2HR 2HR 2HR 2HR 2HR 2HR 2HR 2HR 2HR 2HR

H

R

H R

H

R

H R

H

R

H R

H

R

H R

H

R

H R

H

R

H R

2HR2HR2HR2HR

H

R

H R

H

R

H R

H

R

H R

H

R

H R

H

R

H R

H

R

H R

2HR 2HR 2HR 2HR 2HR

H

R

H R

H

R

H R

H

R

H R

H

R

H R

H

R

H R

H

R

H R

H

R

H R

H

R

H R

H

R

2HR2HR2HR2HR2HR2HR

H

R

H R

H

R

H R

H

R

H R

H

R

H R

H

R

H R

H

R

H R

H

R

H R

H

R

H R

H

R

2HR 2HR 2HR 2HR 2HR 2HR

H

R H

R H

R

H R

H

R

2HR2HR2HR2HR2HR2HR2HR2HR2HR2HR2HR2HR2HR2HR2HR2HR2HR2HR2HR

H

R

H R

H

R

H R

H

R

2HR 2HR 2HR 2HR 2HR 2HR 2HR 2HR 2HR 2HR 2HR 2HR 2HR 2HR 2HR 2HR 2HR 2HR 2HR

H

R

H R

H

R

H

R

H R

2HR2HR2HR

H

R

H R

2HR 2HR 2HR

H

R

H R

SPSPSPSPSP

S P

S P

S P

SP SP SP SP SP

S P

S P

S P

S P

S P

S P

S P

S P

SPSPSPSP

S P

S P

S P

S P

S P

SP SP SP SP

S P

S P

S P

S P

S P

S P

S P

SP SP SP SP SP

S P

S P

S P

S P

S P

S P

S P

SPSPSPSPSP

F

S B

F

S B

F

S B

F

S B

F

S B

F

S B

F

S B

1FSB

F

S B

F

S B

F

S B

F

S B

1FSB 1FSB 1FSB 1FSB 1FSB

F

S B

1FSB 1FSB 1FSB 1FSB

F

S

B

F

S

B

F

S

B

F

S

B

F

S

B

F

S

B

F

S

B

F

S

B

F

S B

F

S B

F

S B

F

S B

F

S B

F

S B

F

S B

F

S B

H

R

1HR1HR1HR1HR1HR1HR1HR1HR1HR

H

R

H R

H

R

H R

H

R

H R

H

R

1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR 1HR

H

R

H R

H

R

H R

H

R

H R

F

S B

F

S B

F

S B

F

S B

F

S B

F

S B

F

S B

F

S B

1FSB

1FSB 1FSB

F

S

B

F

S

B

F

S

B

F

S

B

F

S

B

1FSB 1FSB 1FSB 1FSB 1FSB 1FSB 1FSB

F

S B

H

R

H R

2HR 2HR 2HR 2HR 2HR 2HR 2HR 2HR 2HR 2HR 2HR

H

R

H R

SP SP SP SP SP

S P

S P

S P

S P

SPSPSPSPSP

S P

S P

S P

S P

H

R

H R

H

R

2HR2HR

H

R H

R H

R

2HR 2HR

1HR1HR1HR1HR1HR1HR1HR

H

R

H R

H

R

H R

H

R

H R

H

R

1HR 1HR 1HR 1HR 1HR 1HR 1HR

H

R

H R

H

R

H R

H

R

H R

H

R

2"

2"

2" 2"

2" 2"

1 1

1 1

1 1 1 1 1

OHI

PENDENT SPRINKLER ON DROP

SPRINKLER OR DRAIN RISER

LEGEND

PENDENT SIDEWALL SPRINKLER

ISOLATION VALVE

EXISTING SUPPRESSION PIPING

SPRINKLER SYSTEM BOUNDARY

FIRE HOSE CONNECTION

UPRIGHT SPRINKLER

ORDINARY HAZARD GROUP IOHI

SEISMIC BRACE 2 WAY

SEISMIC BRACE 4 WAY

NEW SUPPRESSION PIPING

INDICATES EXISTING AREA OUTSIDE OF

PROJECT WORK AREA.

WF WATERFLOW SWITCH

VT

VALVE TAMPER SWITCH

2 HOUR FIRE RATED BARRIER

2HR 2HR 2HR 2HR

1HR 1HR 1HR 1HR

1 HOUR FIRE RATED BARRIER

SP SP SP SP SP

SMOKE PARTITION

1FSB 1FSB 1FSB 1FSB

1 HOUR FIRE RATED SMOKE BARRIER

FX101

1/8" = 1'-0"

FIRE SUPPRESSION PLAN - ZONE J

FIRE SUPPRESSION PLAN

SCALE: 1/8" = 1'-0"

0 4' 8' 16'

GENERAL NOTES

1. THIS DRAWING INDICATES THE EXISTING SPRINKLER PIPING CROSS

MAINS FOR USE FOR DEVELOPING THE LAYOUT FOR THE NEW ZONE J

SPRINKLER PIPING SYSTEM.

2. THE CONTRACTOR SHALL LAY-OUT AND INSTALL NEW WET PIPE

AUTOMATIC SPRINKLER PROTECTION THROUGHOUT THE AREA OF WORK

INDICATED.

3. SUBMIT COMPLETE NFPA 13 INSTALLATION PLANS AND HYDRAULIC

CALCULATIONS FOR THE SCOPE OF WORK INDICATED.

4. INSTALL NEW SEMI-RECESSED QUICK RESPONSE SPRINKLERS UNLESS

OTHERWISE NOTED. ALL NEW SPRINKLERS SHALL HAVE A WHITE FINISH

UNLESS OTHERWISE NOTED.

5. MINIMUM PIPE SCHEDULE SHALL BE SCHEDULE 10. PLAIN END FITTINGS

ARE NOT PERMITTED. PIPE 2.5 INCHES AND SMALLER SHALL BE

SCHEDULE 40.

6. PIPE AND HANGER SUPPORTS: PROVIDE PIPE SUPPORTS, HANGERS, AND

CLAMPS IN ACCORDANCE WITH NFPA 13.

7. BRANCH LINE OUTLET FITTINGS: USE THREADED OR GROOVED OUTLETS

ONLY.

8. PLAIN END FITTINGS ARE NOT PERMITTED.

9. SEISMIC BRACING PER NFPA 13, 9.3 IS REQUIRED FOR THE ZONE J

SPRINKLER ZONE. THE INSTALLED SEISMIC BRACING, INCLUDING

FLEXIBLE COUPLINGS SHALL BE DEVELOPED BY THE CONTRACTOR AND

SHOWN ON THE SUBMITTAL WORKING PLANS. SPRINKLER BRANCH LINES

SHALL BE PROVIDED WITH RESTRAINT IN ACCORDANCE WITH NFPA 13,

9.3.6. A SEISMIC DESIGN COEFFICIENT OF CP=0.35 SHALL BE USED FOR

THE CALCULATION OF HORIZONTAL SEISMIC LOADS. PROVIDE SEISMIC

CALCULATIONS FOR EACH SEISMIC BRACE IN ACCORDANCE WITH NFPA

13, 9.3.5.9.

10. NEW PENDENT SPRINKLERS SHALL BE INSTALLED WITH UL LISTED AND

FM APPROVED FLEXIBLE SPRINKLER HOSE FITTINGS.

11. THE CONTRACTOR WORKING PLAN DETAILS SHALL INDICATE

MANUFACTURER LISTING AND INSTALLATION REQUIREMENTS FOR

FLEXIBLE SPRINKLER HOSE FITTINGS.

12. ALL FLEXIBLE SPRINKLER HOSE FITTINGS SHALL BE SIZED WITH A

MINIMUM EXTRA LENGTH OF 1 FOOT TO ACCOMMODATE FUTURE

MODIFICATIONS.

13. DESIGN AND INSTALLATION SHALL BE IN ACCORDANCE WITH NFPA 13,

INSTALLATION OF SPRINKLER SYSTEMS, 2016 EDITION AND

SPECIFICATION 21 13 13.

14. SEE SPECIFICATION 21 13 13 FOR WATER SUPPLY TEST INFORMATION

AND DENSITY DESIGN CRITERIA.

KEYED NOTES

LOCATION OF EXISTING OUTLET FOR CONNECTION OF NEW SPRINKLER.

EXPOSED CEILING AREA. INSTALL UPRIGHT SPRINKLERS. PROVIDE SPRINKLER

COVERAGE BELOW ALL DUCTS 48 INCHES OR WIDER.

EXTEND ZONE 4-2 COVERAGE TO 4J-103. SUPPLY NEW SPRINKLER FROM

ADJACENT ZONE 4-2 BRANCH LINE.

EXTEND ZONE 4-3 SPRINKLER COVERAGE TO ROOM 4J-142, 4J-142A AND

4J-142B.

KEY PLAN

PLAN

NORTH

J o n e e i g h o t t h r e e i n c h e o t o n e a l f i n c h e o t o n e i n o t t h r e e q u a r t e r s i n o t o n e h a l f i n o t t h r e e e i g h t h s i n o t o n e q u a r t e r i n o t

VA FORM 08-6231, OCT 1978

A

123456789

123456789

B

C

D

E

F

A

B

C

D

E

F

Drawing Title Project Title

CheckedBuilding Number Drawn

Date

Project No.

Drawing No.

Location

REVISED CONSTRUCTION DOCUMENTS

V e t e r a n s

A f f a i r s

Approved: Associate Director

Approved: Chief of Staff

Approved: Service Chief

Approved: GEMS Coordinator

Approved: Infection Control Officer

Approved: Safety Manager

Approved: Chief of Mental Health Service

Approved: Chief of Police

Approved: Energy Engineer

Approved: Patient Safety Nurse

Approved: Chief of Facility Management Svc.

Approved: Medical Center Director

A

M

Sheet of

DESIGN/BUILD

VAMC SALEM, VIRGINIA

658-18-101

02/28/2019

90Revisions: Date:

RENOVATE FOR PATIENT

PRIVACY - ZONE J

Corporate Office:

766 Middle St, Fairhope, AL 36532

Phone: 251.990.5778

Fax: 251.990.3716

J UPGRADES 12-4-2019

SRMJAS

1-GI sheets
J-GI001 - TITLE SHEET
Sheets
J-GI001 - TITLE SHEET
J-GI002 - PROJECT INFORMATION SHEET
Sheets
J-GI002 - PROJECT INFORMATION SHEET
J-GI003 - PARTITION TYPES - TYPICAL MOUNTING HEIGHTS
Sheets
J-GI003 - PARTITION TYPES / TYPICAL MOUNTING HEIGHTS
J-GI004 - STANDARD ABBREVIATION
Sheets
J-GI004 - STANDARD ABBREVIATION
J-GI005 - EXISTING CONDITIONS - SCOPE OF WORK
Sheets
J-GI005 - EXISTING CONDITIONS - SCOPE OF WORK
J-GI111 - DEPARTAMENTAL USE PLAN - ZONE J
Sheets
J-GI111 - DEPARTAMENTAL USE PLAN - ZONE J
J-GI112 - DEDUCTIVE ALTERNATE #1
Sheets
J-GI112 - NEW FLOOR PLAN - ZONE J - DEDUCTIVE ALTERNATE #1
J-GI113 - DEDUCTIVE ALTERNATE #2
Sheets
J-GI113 - NEW FLOOR PLAN - ZONE J - DEDUCTIVE ALTERNATE #2
J-GI114 - DEDUCTIVE ALTERNATE #3
Sheets
J-GI114 - NEW FLOOR PLAN - ZONE J - DEDUCTIVE ALTERNATE #3
J-GI115- DEDUCTIVE ALTERNATE #4
Sheets
J-GI115 - NEW FLOOR PLAN - ZONE J - DEDUCTIVE ALTERNATE #4
2-AD sheet
Sheets
J-AD101 - DEMOLITION FLOOR PLAN - ZONE J
J-GI111 - DEPARTAMENTAL USE PLAN - ZONE J
3-AE sheets
J-AE101 - NEW FLOOR PLAN - ZONE J
Sheets
J-AE101 - NEW FLOOR PLAN - ZONE J
J-AE102 - NEW WORK ROOF PLAN - ZONE J
Sheets
J-AE102 - NEW WORK ROOF PLAN - ZONE J
J-AE103 - DOOR SCHEDULE & DOOR - FRAME TYPES
Sheets
J-AE103 - DOOR SCHEDULE & DOOR / FRAME TYPES
J-AE111 - REFLECTED CEILING PLAN
J-AE111 - REFLECTED CEILING PLAN
Sheets
J-AE103 - DOOR SCHEDULE & DOOR / FRAME TYPES
J-AE111 - REFLECTED CEILING PLAN
J-AE301 - BUILDING SECTIONS
Sheets
J-AE301 - BUILDING SECTIONS
J-AE501 - WALL - CEILING DETAILS
Sheets
J-AE501 - WALL - CEILING DETAILS
J-AE502 - ARCHITECTURAL DETAILS
Sheets
J-AE502 - ARCHITECTURAL DETAILS
J-AE503 - ARCHITECTURAL DETAILS
J-AE504 - CASEWORK DETAILS
J-AE505 - CASEWORK DETAILS
J-AE601 - ARCHITECTURAL 3D VIEW
J-AE503 - ARCHITECTURAL DETAILS
Sheets
J-AE502 - ARCHITECTURAL DETAILS
J-AE503 - ARCHITECTURAL DETAILS
J-AE504 - CASEWORK DETAILS
J-AE505 - CASEWORK DETAILS
J-AE601 - ARCHITECTURAL 3D VIEW
J-AE504 - CASEWORK DETAILS
Sheets
J-AE502 - ARCHITECTURAL DETAILS
J-AE503 - ARCHITECTURAL DETAILS
J-AE504 - CASEWORK DETAILS
J-AE505 - CASEWORK DETAILS
J-AE601 - ARCHITECTURAL 3D VIEW
J-AE505 - CASEWORK DETAILS
Sheets
J-AE502 - ARCHITECTURAL DETAILS
J-AE503 - ARCHITECTURAL DETAILS
J-AE504 - CASEWORK DETAILS
J-AE505 - CASEWORK DETAILS
J-AE601 - ARCHITECTURAL 3D VIEW
J-AE601 - ARCHITECTURAL 3D VIEW
Sheets
J-AE502 - ARCHITECTURAL DETAILS
J-AE503 - ARCHITECTURAL DETAILS
J-AE504 - CASEWORK DETAILS
J-AE505 - CASEWORK DETAILS
J-AE601 - ARCHITECTURAL 3D VIEW
4- IN sheets
J-IN101 - FLOOR FINISH PLAN - ZONE J
Sheets
J-IN101 - FLOOR FINISH PLAN - ZONE J
J-IN102 - FINISHES SCHEDULES
J-IN103 - FINISH SELECTIONS
J-IN201 - SIGNAGE PLAN - ZONE J
J-IN202 - SIGNAGE TYPES
J-IN301 - INTERIOR VIEWS
J-IN102 - FINISHES SCHEDULES
Sheets
J-IN101 - FLOOR FINISH PLAN - ZONE J
J-IN102 - FINISHES SCHEDULES
J-IN103 - FINISH SELECTIONS
J-IN201 - SIGNAGE PLAN - ZONE J
J-IN202 - SIGNAGE TYPES
J-IN301 - INTERIOR VIEWS
J-IN103 - FINISH SELECTIONS
Sheets
J-IN101 - FLOOR FINISH PLAN - ZONE J
J-IN102 - FINISHES SCHEDULES
J-IN103 - FINISH SELECTIONS
J-IN201 - SIGNAGE PLAN - ZONE J
J-IN202 - SIGNAGE TYPES
J-IN301 - INTERIOR VIEWS
J-IN201 - SIGNAGE PLAN - ZONE J
Sheets
J-IN101 - FLOOR FINISH PLAN - ZONE J
J-IN102 - FINISHES SCHEDULES
J-IN103 - FINISH SELECTIONS
J-IN201 - SIGNAGE PLAN - ZONE J
J-IN202 - SIGNAGE TYPES
J-IN301 - INTERIOR VIEWS
J-IN202 - SIGNAGE TYPES
Sheets
J-IN101 - FLOOR FINISH PLAN - ZONE J
J-IN102 - FINISHES SCHEDULES
J-IN103 - FINISH SELECTIONS
J-IN201 - SIGNAGE PLAN - ZONE J
J-IN202 - SIGNAGE TYPES
J-IN301 - INTERIOR VIEWS
J-IN301 - INTERIOR VIEWS
Sheets
J-IN101 - FLOOR FINISH PLAN - ZONE J
J-IN102 - FINISHES SCHEDULES
J-IN103 - FINISH SELECTIONS
J-IN201 - SIGNAGE PLAN - ZONE J
J-IN202 - SIGNAGE TYPES
J-IN301 - INTERIOR VIEWS
5- QH sheets
J-QH101 - EQUIPMENT PLAN - ZONE J
Sheets
J-QH101 - EQUIPMENT PLAN - ZONE J
J-QH401 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH402 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH403 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH404 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH405 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH406 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH401 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
Sheets
J-QH101 - EQUIPMENT PLAN - ZONE J
J-QH401 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH402 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH403 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH404 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH405 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH406 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH402 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
Sheets
J-QH101 - EQUIPMENT PLAN - ZONE J
J-QH401 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH402 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH403 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH404 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH405 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH406 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH403 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
Sheets
J-QH101 - EQUIPMENT PLAN - ZONE J
J-QH401 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH402 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH403 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH404 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH405 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH406 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH404 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
Sheets
J-QH101 - EQUIPMENT PLAN - ZONE J
J-QH401 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH402 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH403 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH404 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH405 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH406 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH405 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
Sheets
J-QH101 - EQUIPMENT PLAN - ZONE J
J-QH401 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH402 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH403 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH404 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH405 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH406 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
J-QH406 - ENLARGED VIEWS AND INTERIOR ELEVATIONS
Sheets
J-QH406 - ENLARGED VIEWS AND INTERIOR ELEVATIONS

File details come from the government source that posted it. Updated .