PAINT IDIQ LINE ITEMS 1
PAINT IDIQ ITEMS ROBINS AFB
| LINE ITEM # | DESCRIPTION | EST. QTY. | PRICE (NOT TO EXCEED) | UNIT | BASE YEAR SUBTOTAL | OPTION YEAR 1 PRICE (NOT TO EXCEED) | UNIT | OPTION YEAR 1 SUBTOTAL | OPTION YEAR 2 PRICE (NOT TO EXCEED) | UNIT | OPTION YEAR 2 SUBTOTAL | OPTION YEAR 3 PRICE (NOT TO EXCEED) | UNIT | OPTION YEAR 3 SUBTOTAL | OPTION YEAR 4 PRICE (NOT TO EXCEED) | UNIT | OPTION YEAR 4 SUBTOTAL |
| INTERIOR PAINTING OF WALLS WITH LATEX PAINT UP TO 10’ HIGH ROLLED | |||||||||||||||||
| GYPSUM BOARD, PLASTER, CMU, BRICK, CONCRETE: | |||||||||||||||||
| LIGHT SURFACE PREPARATION | |||||||||||||||||
| 1 | INCLUDES DROP CLOTH, REMOVE/REPLACE LIGHT SWITCH & RECEPTACLES COVERS, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 10%-30% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE FINISH COAT | 25,000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 1A | INCLUDES DROP CLOTH, REMOVE/REPLACE LIGHT SWITCH & RECEPTACLES COVERS, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 10%-30% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, TWO FINISH COATS | 25000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 1B | INCLUDES DROP CLOTH, REMOVE/REPLACE LIGHT SWITCH & RECEPTACLES COVERS, CLEANING, CAULKING, PATCHING AND SPOT PRIMING UP TO 10%-30% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE PRIMER AND TWO FINISH COATS | 10000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| MEDIUM SURFACE PREPARATION | 1 | ||||||||||||||||
| 2 | INCLUDES DROP CLOTH, REMOVE/REPLACE LIGHT SWITCH & RECEPTACLES COVERS, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 30%-70% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE FINISH COAT | 10000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 2A | INCLUDES DROP CLOTH, REMOVE/REPLACE LIGHT SWITCH & RECEPTACLES COVERS, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 30%-70% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, TWO FINISH COATS | 20000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 2B | INCLUDES DROP CLOTH, REMOVE/REPLACE LIGHT SWITCH & RECEPTACLES COVERS, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 30%-70% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE PRIMER AND TWO FINISH COATS | 10000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| HEAVY SURFACE PREPARATION | |||||||||||||||||
| 3 | INCLUDES DROP CLOTH, REMOVE/REPLACE LIGHT SWITCH & RECEPTACLES COVERS, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 70%-100% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE FINISH COAT | 25,000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 3A | INCLUDES DROP CLOTH, REMOVE/REPLACE LIGHT SWITCH & RECEPTACLES COVERS, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 70%-100% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, TWO FINISH COATS | 20,000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 3B | INCLUDES DROP CLOTH, REMOVE/REPLACE LIGHT SWITCH & RECEPTACLES COVERS, CLEANING, CAULKING, PATCHING AND SPOT PRIM UP TO 70%-100% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE PRIMER AND TWO FINISH COATS | 10,000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| PAINTING OF INTERIOR WALLS WITH LATEX PAINT OVER 10’ AND UNDER 18' HIGH | |||||||||||||||||
| GYPSUM BOARD (SHEET ROCK), PLASTER, CMU, BRICK, CONCRETE: | |||||||||||||||||
| LIGHT SURFACE PREPARATION | |||||||||||||||||
| 4 | INCLUDES SCAFFOLDING, DROP CLOTH, REMOVE/REPLACE LIGHT SWITCH & RECEPTACLES COVERS, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 10%-30% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE COAT | 5000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 4A | INCLUDES SCAFFOLDING, DROP CLOTH, REMOVE/REPLACE LIGHT SWITCH & RECEPTACLES COVERS, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 10%-30% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, TWO FINISH COATS | 10000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 4B | INCLUDES SCAFFOLDING, DROP CLOTH, REMOVE/REPLACE LIGHT SWITCH & RECEPTACLES COVERS, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 10%-30% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE PRIMER AND TWO FINISH COATS | 5000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| MEDIUM SURFACE PREPARATION | |||||||||||||||||
| 5 | INCLUDES SCAFFOLDING DROP CLOTH, REMOVE/REPLACE LIGHT SWITCH & RECEPTACLES COVERS, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 30%-70% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE COAT | 5000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 5A | INCLUDES SCAFFOLDING, DROP CLOTH, REMOVE/REPLACE LIGHT SWITCH & RECEPTACLES COVERS, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 30%-70% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, TWO FINISH COATS | 10000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 5B | INCLUDES SCAFFOLDING, DROP CLOTH, REMOVE/REPLACE LIGHT SWITCH & RECEPTACLES COVERS, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 30%-70% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE PRIMER AND TWO FINISH COATS | 5000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| HEAVY SURFACE PREPARATION | |||||||||||||||||
| 6 | INCLUDES SCAFFOLDING, DROP CLOTH, REMOVE/REPLACE LIGHT SWITCH & RECEPTACLES COVERS, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 70%-100% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE COAT | 5000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 6A | INCLUDES SCAFFOLDING, DROP CLOTH, REMOVE/REPLACE LIGHT SWITCH & RECEPTACLES COVERS, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 70%-100% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, TWO FINISH COATS | 10000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 6B | INCLUDES SCAFFOLDING, DROP CLOTH, REMOVE/REPLACE LIGHT SWITCH & RECEPTACLES COVERS, CLEANING, CAULKING, PATCHING UP TO 70%-100% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE PRIMER AND TWO FINISH COATS | 15000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| INTERIOR PAINTING OF CEILINGS UP TO 10’ HIGH FROM FINISHED FLOOR | |||||||||||||||||
| GYPSUM BOARD (SHEET ROCK), PLASTER, ACOUSTICAL TILE, CELOTEX TILE, CONCRETE: | |||||||||||||||||
| 7 | INCLUDES DROP CLOTH, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 10%-30% OF CEILING SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE COAT | 10000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 7A | INCLUDES DROP CLOTH, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 10%-30% OF CEILING SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, TWO COATS | 10000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| INTERIOR PAINTING OF CEILINGS BETWEEN 10’ AND 18' HIGH FROM FINISHED FLOOR | |||||||||||||||||
| GYPSUM BOARD (SHEET ROCK), PLASTER, ACOUSTICAL TILE, CELOTEX TILE, CONCRETE: | |||||||||||||||||
| 8 | INCLUDES DROP CLOTH, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 10%-30% OF CEILING SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE COAT | 10000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 8A | INCLUDES DROP CLOTH, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 10%-30% OF CEILING SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, TWO COATS | 10000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| EXTERIOR PAINTING OF WALLS WITH LATEX PAINT UP TO 14’ HIGH, ROLLED OR SPRAYED AND BACK ROLLED | |||||||||||||||||
| METAL, CMU, BRICK, CONCRETE: | |||||||||||||||||
| LIGHT SURFACE PREPARATION | |||||||||||||||||
| 9 | INCLUDES PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 10%-30% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE FINISH COAT | 15000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 9A | INCLUDES PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 10%-30% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, TWO FINISH COATS | 35000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 9B | INCLUDES PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, CAULKING, PATCHING UP TO 10%-30% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE PRIMER AND TWO FINISH COATS | 30000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| MEDIUM SURFACE PREPARATION | |||||||||||||||||
| 10 | INCLUDES PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 15% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE FINISH COAT | 20000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 10A | INCLUDES PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 30%-70% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, TWO FINISH COATS | 20000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 10B | INCLUDES PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, CAULKING, PATCHING UP TO 30%-70% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE PRIMER AND TWO FINISH COATS | 30000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| HEAVY SURFACE PREPARATION | |||||||||||||||||
| 11 | INCLUDES PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 70%-100% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE FINISH COAT | 20000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 11A | INCLUDES PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 70%-100% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, TWO FINISH COATS | 10000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 11B | INCLUDES PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, CAULKING PATCHING UP TO 70%-100% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE PRIMER AND TWO FINISH COATS | 30000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| EXTERIOR PAINTING OF WALLS WITH LATEX OVER 14’ HIGH, ROLLED OR SPRAYED AND BACK ROLLED | |||||||||||||||||
| Metal, CMU, BRICK, CONCRETE: | |||||||||||||||||
| LIGHT SURFACE PREPARATION | |||||||||||||||||
| 12 | INCLUDES MAN LIFT, PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 10%-30% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE FINISH COAT | 20000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 12A | INCLUDES MAN LIFT, PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, CAULKING, PATCHING &SPOT PRIMING UP TO 10%-30% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, TWO FINISH COATS | 30000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 12B | INCLUDES MAN LIFT, PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, CAULKING, PATCHING &SPOT PRIMING UP TO 10%-30% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE PRIMER AND TWO FINISH COATS | 20000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| MEDIUM SURFACE PREPARATION | |||||||||||||||||
| 13 | INCLUDES MAN LIFT, PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 30%-70% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE FINISH COAT | 30000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 13A | INCLUDES MAN LIFT, PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 30%-70% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, TWO FINISH COATS | 30000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 13B | INCLUDES MAN LIFT, PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 30%-70% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE PRIMER AND TWO FINISH COATS | 30000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| HEAVY SURFACE PREPARATION | |||||||||||||||||
| 14 | INCLUDES MAN LIFT, PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 70%-100% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, TWO FINISH COATS | 20000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 14A | INCLUDES MAN LIFT, PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 70%-100% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, TWO FINISH COATS | 30000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 14B | INCLUDES MAN LIFT, PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 70%-100%OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE PRIMER AND TWO FINISH COATS | 30000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| PAINTING WITH DRY FALL PAINT , SPRAYED | |||||||||||||||||
| METAL, CMU, BRICK, CONCRETE OVER 14' | |||||||||||||||||
| LIGHT SURFACE PREPARATION | |||||||||||||||||
| 15 | INCLUDES MAN LIFT, PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 10%-30% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE FINISH COAT | 15000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 15A | INCLUDES MAN LIFT, PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 10%-30% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, TWO FINISH COATS | 20000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 15B | INCLUDES MAN LIFT, PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, PATCHING UP TO 10%-30% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE PRIMER AND TWO FINISH COATS | 10000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| MEDIUM SURFACE PREPARATION | |||||||||||||||||
| 16 | INCLUDES MAN LIFT, PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 30%-70% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE FINISH COAT | 10000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 16A | INCLUDES MAN LIFT, PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, CAULKING, PATCHING & SPOT PRIMING UP TO 30%-70% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, TWO FINISH COATS | 20000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 16B | INCLUDES MAN LIFT, PRESSURE WASHING / PAINT CHIP CONTAINMENT, CLEANING, CAULKING, PATCHING UP TO 30%-70% OF WALL SURFACE, CAPTURING, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE PRIMER AND TWO FINISH COATS | 15000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| PAINT PERSONNEL DOORS: OIL BASED PAINT BRUSHED, INCLUDING FRAMES AND TRIM, WOOD OR METAL | |||||||||||||||||
| 17 | INCLUDES DROP CLOTH, SURFACE PREPARATION, PATCH AND SPOT PRIME, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE FINISH COAT | 2000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 17A | INCLUDES DROP CLOTH, SURFACE PREPARATION, PATCH AND SPOT PRIME, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, TWO FINISH COATS | 1000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 17B | INCLUDES DROP CLOTH, SURFACE PREPARATION, PATCH AND SPOT PRIME, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE PRIME AND TWO FINISH COATS | 1000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| PAINT WINDOW: LATEX PAINT BRUSHED , INCLUDING FRAMES AND TRIM | |||||||||||||||||
| 18 | INCLUDES DROP CLOTH, SURFACE PREPARATION, PATCH AND SPOT PRIME, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS,ONE FINISH COAT | 1000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 18A | INCLUDES DROP CLOTH, SURFACE PREPARATION, PATCH AND SPOT PRIME, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, TWO FINISH COATS | 1000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| PAINT ROLL-UP DOORS: INDUSTRIAL ENAMEL SPRAYED, INCLUDING FRAMES AND TRIM, METAL | |||||||||||||||||
| 19 | INCLUDES DROP CLOTH, SURFACE PREPARATION, PATCH AND SPOT PRIME, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE FINISH COAT | 2500 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 19A | INCLUDES DROP CLOTH, SURFACE PREPARATION, PATCH AND SPOT PRIME, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, TWO FINISH COATS | 5000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| PAINT TRIM: 6" , LATEX OR OIL BRUSHED MISCELLANEOUS METAL OR WOOD | |||||||||||||||||
| 20 | INCLUDES DROP CLOTH, SURFACE PREPARATION, PATCH AND SPOT PRIME, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, ONE FINISH COAT | 5000 | LF | LF | LF | LF | LF | ||||||||||
| 20A | INCLUDES DROP CLOTH, SURFACE PREPARATION, PATCH AND SPOT PRIME, CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, PAINT BUCKETS, BRUSHES, ROLLER COVERS, TWO FINISH COATS | 5000 | LF | LF | LF | LF | LF | ||||||||||
| WALL COVERING REMOVAL | |||||||||||||||||
| 21 | REMOVE WALL COVERINGS ONE OR TWO LAYERS, PATCH AND REPAIR WALL WITH MEDIUM DAMAGE TO SHEETROCK. INCLUDES CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF WALL COVERING & PAINT CHIPS, | 25000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| WALL COVERING | |||||||||||||||||
| 22 | INSTALL KOROSEAL "COLLAGE" 21.0 OZ, 22 MILS. | 25000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| COVE BASE VINYL | |||||||||||||||||
| 23 | REMOVE AND INSTALL 4" VINYL COVE BASE | 12000 | LF. | LF. | LF. | LF. | LF. | ||||||||||
| 23A | REMOVE AND INSTALL 6" VINYL COVE BASE | 5000 | LF. | LF. | LF. | LF. | LF. | ||||||||||
| 23B | INSTALL 4" INSIDE OR OUTSIDE CORNER | 1500 | EA. | EA. | EA. | EA. | EA. | ||||||||||
| 23C | INSTALL 6" INSIDE OR OUTSIDE CORNER | 1500 | EA. | EA. | EA. | EA. | EA. | ||||||||||
| WOOD TRIM COMPLETE WITH FINISH | |||||||||||||||||
| 24 | INSTALL 4" STAIN GRADE OAK | 1000 | LF. | LF. | LF. | LF. | LF. | ||||||||||
| 24A | INSTALL 2 1/2" PAINT GRADE TRIM AROUND DOORS AND WINDOWS | 2000 | LF. | LF. | LF. | LF. | LF. | ||||||||||
| 24B | INSTALL 3 1/2" PAINT GRADE TRIM AROUND DOORS AND WINDOWS | 2000 | LF. | LF. | LF. | LF. | LF. | ||||||||||
| 24C | INSTALL 3" STAIN GRADE OAK TRIM AROUND DOORS AND WINDOWS | 1000 | LF. | LF. | LF. | LF. | LF. | ||||||||||
| EPOXY FLOORS | |||||||||||||||||
| 25 | SHOT BLAST CONCRETE FLOORS MINIMUM. INCLUDES CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, | 15000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 25A | SHOT BLAST CONCRETE FLOORS MAXIMUM. INCLUDES CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, | 15000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 25B | HAND GRIND AROUND EDGES AND OBSTRUCTIONS. INCLUDES CONTAINING TESTING AND PROPER APPROVED DISPOSAL OF PAINT CHIPS, | 5000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 25C | INSTALL HIGH SOLID EPOXY INTERMEDIATE COAT 18 MILS WITH ALUMINUM OXIDE AGGREGATE. INCLUDES PROPER APPROVED DISPOSAL OF PAINT BUCKETS, BRUSHES, ROLLER COVERS | 15000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 25D | INSTALL URETHANE TOP COAT 8 MILS. INCLUDES PROPER APPROVED DISPOSAL OF PAINT BUCKETS, BRUSHES, ROLLER COVERS | 15000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 25E | PAINT FIRE LANE LINES 6". INCLUDES PROPER APPROVED DISPOSAL OF PAINT BUCKETS, BRUSHES, ROLLER COVERS | 10000 | LF. FT. | LF. FT. | LF. FT. | LF. FT. | LF. FT. | ||||||||||
| MISC. OSHA TESTING | |||||||||||||||||
| 26 | INDUSTRIAL HYGIENIST | 100 | HR. | HR. | HR. | HR. | HR. | ||||||||||
| 26E | AIR SAMPLING FOR LEAD | 100 | EA. | EA. | EA. | EA. | EA. | ||||||||||
| 26F(R1 4-4-11) | LEAD PAINT REMEDIATION PLANS AND METHODS, LEAD PAINT TESTING, X-RAY FLUORESCENCE, AAS ANALYSIS | 100 | EA. | EA. | EA. | EA. | EA. | ||||||||||
| LEAD BASED PAINT ABATEMENT/ENCAPSULATION | |||||||||||||||||
| 27(R1 4-4-11) | REMOVAL OF LEAD-BASED PAINT, BY CHEMICALS, PER APPLICATION, MISCELLANEOUS, SIDING, DOORS, TRUSSES, BLOCK, BRICK | 20,000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 27A(R1 4-4-11) | ENCAPSULATIION OF LEAD-BASED PAINT, INTERIOR, ROLLER,BRUSHWORK, WALLS, DRYWALL, PLASTER, CEILINGS, WOOD, GRILLES, VENTS | 10,000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | ||||||||||
| 27B(R1 4-4-11) | ENCAPSULATIION OF LEAD-BASED PAINT, EXTERIOR, SPRAY, MISCELLANEOUS, BRICK, BLOCK, CONCRETE, STEELL, TRUSSES, SIDING , GUTTERS AND DOWNSPOUTS, COLUMNS | 20,000 | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. | SQ. FT. |
BASE YEAR TOTAL EVALUATED PRICE OPTION YEAR 1 TOTAL EVALUATED PRICE OPTION YEAR 2 TOTAL EVALUATED PRICE OPTION YEAR 3 TOTAL EVALUATED PRICE OPTION YEAR 4 TOTAL EVALUATED PRICE $0.00