BLDG._503_EXTERIOR_UPGRADE_SET_sow.pdf
PDF 11 MB Posted
- Attached to
- Bldg. 503 Repair/Minor Const/Equipment Federal contract opportunity
- Solicitation number
- FA8201-16-B-0009
About this file
B503 Exterior Upgrade SOW Drawings
View the file
Other files for this federal contract opportunity
Show all 50
Bldg. 503 Repair/Minor Const/Equipment has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OGDEN, UTAHHILL AIR FORCE BASE
PROJECT ARCHITECT
GSBS ARCHITECTS
375 WEST 200 SOUTH
SALT LAKE CITY, UT 84101
PHONE 801.521.8600
FAX 801.521.7913
GTS
GSBS
M. KEMSLEY
A-E DESIGNER
A-E FIRM
DESCRIPTION BY
DRAWN BY
OGDEN, UTAH
DATE
DATE
DATE
DATE
REVISION
DATE
DATE
DATE
HILL AIR FORCE BASE
ELECTRICAL REVIEW
MECHANICAL REVIEW
CIVIL/STRUCTURAL REVIEW
PHYS HANDICAP/INT DESIGN
BASE COMPREHENSIVE PLANNER
ARCHITECTURAL COMPATIBILITY
DEPARTMENT OF THE AIR FORCE
OGDEN AIR LOGISTICS CENTER
75TH CIVIL ENGINEERING GROUP
DATE
DATE
DATE
DATE DATE
BASE FILE NO.
KRSM 092001 A/B/C
PROJECT NO.
BASE PROJECT MANAGER
DATE
DATE
DATE
DATE
DATE
DATE
DATE
DATE
DATE
DATE
COMMUNICATIONS
SAFETY
DATE FIRE DEPARTMENT
BIOENVIRONMENTAL REVIEW
ENVIRONMENTAL REVIEW
CUSTOMER-FUNCTIONAL REVIEW
CORROSION ENGINEER
ENERGY CONSERVATION REVIEW
FIRE PROTECTION REVIEW
SECURITY FORCES
CHIEF ENGINEER
775 CES COMMANDER
CHIEF PROJECT MANAGEMENT
MAINTENANCE ENGINEERING
APPROVED-75 CEG
WO
COVER SHEET
EXTERIOR UPGRADE
092001 A/B/C
ELECTRICAL ENGINEER
EDG ENGINEERING
3580 SOUTH 6000 WEST
WEST VALLEY CITY, UT 84128
PHONE 801.397.3535
FAX 801.315.0702
NOTE:
REFER TO SPECIFICATION
SECTION 01000 FOR GENERAL
REQUIREMENTS RELATED
TO THIS WORK
ARCHITECTURAL REVIEW DATECIVIL ENGINEER
CALDWELL RICHARDS SORENSEN
2060 EAST 2100 SOUTH
SALT LAKE CITY, UT 84109
PHONE 801.359.5565
FAX 801.359.4272
COST ESTIMATING
PARAMETRIX
7186 SOUTH HIGHLAND DRIVE
SALT LAKE CITY, UT 84121
PHONE 801.733.5900
FAX 801.733.5500
STRUCTURAL ENGINEER
REAVELEY ENGINEERS
675 EAST 500 SOUTH, SUITE 400
SALT LAKE CITY, UT 84102
PHONE 801.486.3883
FAX 801.485.0911
FRAGMENT RETENTION FILM
FAMILY SUPPORT CENTER
HILL AIR FORCE BASE
GENERAL CONTRACTOR
FIRE EXTINGUISHER
EXPANSION JOINT
CABINET
GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
CONTRACTOR INSTALLED
ELEVATION
EQUAL
EACH SIDE
EXISTING
EXPANSION
EXTERIOR
ELECTRIC WATER COOLER
FLOOR DRAIN
FOUNDATION
FIRE EXTINGUISHER
FINISH FLOOR
FINISH
FLOOR
FOOTING
GAGE/GAUGE
GALVANIZED
GOVERNMENT FURNISHED
GROUND
GOVERNMENT
GYPSUM WALL BOARD
GYPSUM WALL BOARD
HANDICAPPED
HARDWARE
HOLLOW METAL
HORIZONTAL
HOUR
ELEVATION
GALLONS PER MINUTE
GALLON
EACH FACE
HEADED STUD ANCHOR
EACH WAY
CONSTRUCTION JOINT C.J. GALV.
CONTRACTION JOINT
CONCRETE MASONRY UNIT
CONCRETE
CONTINUOUS
CONSTRUCTION
COORDINATE
DEPARTMENT
DEFORMED BAR ANCHOR
DIA.
DTL.
DWGS.
DEPT
DET.
D.B.A.
DIAMETER
DETAIL
DRAWINGS
DETAIL
C.T.J.
CLG.
CLR.
CMU
COL.
CONC.
CONT.
CONST.
COORD.
DBL. DOUBLE
CEILING
CLEAR
COLUMN
H.A.F.B.
H.S.A.
HC.
HDW.
H.M.
HORIZ.
HR.
GYP. BD.
GND.
GOVT.
GWB.
GPM
G.C.
GFGI
GFCI
L ANGLE
TESTING MATERIALS
ADJUSTABLE
ABOVE FINISH FLOOR
AMERICAN SOCIETY FOR
BITUMINOUS
BENCHMARK
BOTTOM OF
APPROXIMATE
BASE PLATE
ANCHOR BOLT
ARCHITECTURAL
BITUM.
BD.
BLDG.
B.M.
B.O.
BRG.
BTWN.
CER.
B.P.
BOT. BOTTOM
BEARING
BETWEEN
CERAMIC
BOARD
BUILDING
ADJ.
A.F.F.
ALUM.
A.S.T.M.
APPROX.
A.B.
ARCH.
ABV.
ALUMINUM
ABOVE
F.E.
FLR.
F.R.F.
FTG.
GA.
GAL.
FT. FEET
F.E.C.
F.F.
FIN.
EXPAN.
F.S.C.
EXT.
E.W.C.
F.D.
FDN.
ELEV.
EQ.
E.S.
EXIST.
E.W.
CENTER LINE
CL
NUMBER
AT
DIAMETER
E.J.
EA.
EL.
E.F.
EACH
N.T.S. NOT TO SCALE
T.O.W.
U.N.O.
PL. LAM.
P.S.I.
PNTD.
PROT.
P.S.F.
P.L.F.
OHD
PERP.
OPP.
PART.
P.C.F.
O.C.
O.D.
O.H.
O.F.
VCT PLASTIC LAMINATE
POUNDS PER SQUARE INCH
POUNDS PER LINEAL FOOT
SQUARE FOOT
PROTECTION
POUNDS PER
PAINTED
W/
WD.
VERT.
VEST.
VNR.
OUTSIDE DIAMETER
POUNDS PER CUBIC FOOT
OVERHEAD DOOR
PERPENDICULAR
OPPOSITE
PARTITION
ON CENTER
OVERHEAD
OUTSIDE FACE
TV
VCR
T.O.F.
T.O.S.
TYP.
VINYL COMPOSITION
WITH
WOOD
TILE
VERTICAL
VESTIBULE
VENEER
VIDEO CASSETTE
TOP OF FOOTING
TOP OF SLAB
TOP OF WALL
UNLESS NOTED
TELEVISION
RECORDER
OTHERWISE
OR SIDWALK
TYPICAL
REINF.
REQ'D
SPEC.
SUSP.
T.O.C.
SUPER.
SCHED.
I.D. INSIDE DIAMETER
MISC.
M.O.
MTL.
N.I.C.
NO.
MECH.
MIN.
MAT.
MFR.
M.C.J.
LAV.
LT.
MANUF.
MAINT.
MAX.
LT. WT.
INFO.
INSUL.
I.F.
IN.
MASONRY OPENING
NOT IN CONTRACT
MASONRY CONTROL JOINT
MISCELLANEOUS
METAL
NUMBER
MECHANICAL
MATERIAL
MANUFACTURER
MINIMUM
T
THRU
T.O.
T.O.A.
STD.
STR.
LAVATORY
MANUFACTURER
MAINTENANCE
LIGHT WEIGHT
LIGHT
MAXIMUM
INFORMATION
INSULATION
INSIDE FACE
INCHES
SHT.
SQ.
ST
SIM.
STC
RM.
R.O.
SHR.
HYD
HT.
HVAC
AIR CONDITIONING
HEATING/VENTILATION/
HYDRANT
HEIGHT
R.D.
RAD.
QTY.
REQUIRED
TEMPERED GLASS
TOP OF ASPHALT
TOP OF CURB
THROUGH
TOP OF
COEFFICIENT
STANDARD
STRUCTURAL
SUSPENDED
SUPERVISER
ROUGH OPENING
SPECIFICATION
SOUND TRANSMISSION
SHEET
SQUARE
STEEL
SIMILAR
ROOM
SHOWER
SCHEDULE
ROOF DRAIN
RADIUS
REINFORCED
QUANTITY
GRAVEL
EARTH
QUARRY/CERAMIC TILE
CONCRETE (POURED IN PLACE)
GYPSUM BOARD OR SETTING BEDS
INSULATION (BATT & BLANKET)
INSULATION (RIGID/SEMI-RIGID)
PLYWOOD
CONTINUOUS ROUGH WOOD
METAL (LARGE SCALE)
BLOCKING, ROUGH WOOD
FACE BRICK
CONCRETE MASONRY UNIT
PROJECT LOCATION
A
B
C
D
(TYP FOR ALL SHEETS)GENERAL NOTES:
SOUTH GATE
WEST GATE
CONTRACTING
6038 ASPEN AVE
BLDG. 1289
NE
SECURITY POLICE BLDG. 1219
ROY GATE
NORTH GATE
CIVIL ENGR
BLDG 593
FIRE DEPARTMENT
BLDG. 9
RCP REFLECTED CEILING PLAN
GENERAL
1. G001 COVER SHEET
2. G002 INDEX, CODE CRITERIA, MAPS,
ABBREVIATIONS
CIVIL
3. C101 SITE PLAN SOUTH
4. C101A STRIPING PLAN
5. C102 SITE PLAN NORTH
6. C103 SITE PLAN DETAILS
7. C104 SITE PLAN DETAILS
8. C105 SITE PLAN DETAILS
9. C501 SITE DETAILS
10. C502 SITE DETAILS
LANDSCAPE
11. LS-101 LANDSCAPING AND PLANTING PLAN
ARCHITECTURAL
12. A101 SITE PLAN SOUTH
13. A102 SITE PLAN NORTH
14. A102A STRIPING PLANS
15. A501 DETAILS
STRUCTURAL
16. S-001 GENERAL STRUCTURAL NOTES
17. S-002 GENERAL STRUCTURAL NOTES
18. S-101 STRUCTURAL PLANS
19. S-501 FOOTING AND FOUNDATION DETAILS
& SCHEDULES
20. S-502 STRUCTURAL DETAILS
21. S-503 FOOTING AND FOUNDATION DETAILS,
SCHEDULES
ELECTRICAL
22. E0.1 NOTES - SYMBOLS - SCHEDULES
23. E0.2 ELECTRICAL DETAILS
24. E4.0 BLDG 503 REPAIRS AND SECURITY
GATES
25. E4.1 BLDG 503 REPAIRS AND SECURITY
GATES
26. E4.2 BLDG 503, 507, AND 509 SECURITY
UPGRADES
E X
TE
R
IO
R
U P
G R
A D
E B
U
IL
D
IN
G
R
EP
A
IR
/M
IN
O R
C O
N
ST
NOTES
GENERAL STRUCTURAL GSN
IBC INTERNATIONAL BUILDING
CODE
IR IRRIGATION
EXISTING EXG
5 EA.
5 EA.
5 EA.
5 EA.
MATCH LINE - SEE SHEET C102
GRAPHIC SCALE
( IN FEET )
020 10 20 40
1" = 20'-0"
N
SEE DETAIL - SHEET C103
SEE DETAIL - SHEET C105
SEE DETAIL - SHEET C104
19 EXISTING SMOKING
SHELTERS
8 EA.
BLDG. 503A
E X
TE
R
IO
R
U P
G R
A D
E B
U
IL
D
IN
G
S
IT
E P
LA
N
(S
O U
TH
R
EP
A
IR
/M
IN
O R
C O
N
ST
EXISTING
BLDG. 507
CONCRETE EXTERIOR SPECIFICATION: BUILDING 503/503A /503B
COLUMNS, STEPS, BOLLARDS AND CONCRETE REPAIR- BASIS OF DESIGN
SCOPE: TO PROVIDE LONG TERM PRESERVATION TO EXTERIOR BUILDING
APPURTENANCES WHILE ENHANCING SAFETY. ENSURE MANUFACTURERS
DATA IS FOLLOWED EXPLICITLY.
COLUMNS: CHIP OR GRIND THE CONCRETE FROM AROUND THE BASE
(ONLY ABOUT 1/8TH INCH TO OPEN THE GAP FOR APPLICATION). WITH A
PFERD POWER WIRE BRUSH CLEAN COLUMN DOWN INTO GAP AS FAR AS
FEASIBLE. WITH A VACCUM CLEAN OUT ALL DEBRIS IN JOINT AREA AND
THEN INJECT LOCTITE EXTEND (75448 GAL. OR 75430 QT.) INTO THE BASE
CAVITY TO CONVERT THE RUST. AFTER APPROPRIATE CURE TIME OF
LOCTITE EXTEND COMPLETELY FILL BASE CAVITY WITH WHITE LIGHTNING
POLYURETHANE SEALER (WL091160A) SO IT IS FLUSH WITH CONCRETE.
SAND BLAST THE LOWER 24 INCHES OF ALL COLUMNS TO INSURE ALL
RUST IS REMOVED. APPLY LOCTITE EXTEND TO CLEANED SURFACE AND
ALLOW APPROPRIATE CURE TIME. APPLY HIGH GLOSS POLYURETHANE
COATING (KRYLON K0408 SERIES SANDSTONE) TO PRIMED AREA. USE
WHITE LIGHTNING POLYURETHANE SEALER (WL091160A) TO FILL JOINT
WHERE COLUMN AND CONCRETE JOIN TO ACHIEVE A RAISED TAPERED
SEAL TO STOP WATER INGRESS INTO JOINT.
STEPS: REMOVE METAL BULL NOSE PLATES FROM STEPS AND
SANDBLAST ENTIRE STEP AREA. IF REQUIRED REINSTALL WITH NEW
ANCHORS AND REPLACE ANY DAMAGED METAL BULL NOSE PLATES. SAND
BLAST METAL BULL NOSE PLATES AND COAT WITH HIGH GLOSS
POLYURETHANE COATING (KRYLON K0408 SERIES GRAY), APPLY SHARK
GRIP ADDITIVE (50.055005-99) TO OUTER WALK SURFACE OF PLATES. FILL
VOIDS IN CONCRETE WITH LOCTITE MAGNA-CRETE, MIXED TO
APPROPRIATE CONSISTENCY DEPENDENT UPON VERTICAL, HORIZONTAL
AND DEPTH REQUIREMENTS. USING THE HIGH GLOSS POLYURETHANE
COATING (KRYLON K0408 SERIES GRAY) WITH SHARK GRIP ADDITIVE
(50.055005-99) COAT ENTIRE STEP SURFACE. APPLY MINIMUM SHARK
GRIP ADDITIVE (50.055005-99) TO PLATE INSET AREA. REINSTALL METAL
BULL NOSE PLATES. USING WHITE LIGHTNING POLYURETHANE SEALER
(WL091160A) SEAL ALL JOINTS AROUND METAL BULL NOSE PLATES TO
STOP WATER INGRESS UNDER BULL NOSE PLATES.
BOLLARDS: SAND BLAST SURFACE TO REMOVE ALL LOOSE MATERIAL.
APPLY THE HIGH GLOSS POLYURETHANE COATING (K0408 SERIES,
SANDSTONE) TO PREVENT FURTHER DEGRADATION OF SURFACE.
CONCRETE REPAIR: METICULOUS SURFACE PREPARATION IS ESSENTIAL.
CONTRACTOR SHALL DEMONSTRATE THIS AND HAVE A QUALITY
VERIFICATION PROGRAM ENSURING COMPLIANCE WITH
MANUFACTURERS SPECIFICATIONS. REPAIR MATERIALS USED SHALL BE
PART OF A DESIGNED AND ENGINEERED SYSTEM SPECIFICALLY FOR
ADDRESSING THE COMPLETE CONCRETE REPAIR REQUIREMENTS OF
THIS PROJECT. E.G. HENKEL FIXMASTER CRACK FILLER NON SAG OR
EQUAL IS AN APPROVED PRODUCT AS IT IS PART OF A ENGINEERED
SYSTEM.
GRAPHIC SCALE
( IN FEET )
040 20 40 80
1" = 40'-0"
N
BLDG. 503A
E X
TE
R
IO
R
U P
G R
A D
E B
U
IL
D
IN
G
S
TR
IP
IN
G P
LA
N
R
EP
A
IR
/M
IN
O R
C O
N
ST
EXISTING
BLDG. 507
GENERAL NOTES:
CONTRACTOR SHALL RE-STRIPE EXISTING PARKING LOT BETWEEN
BUILDING 503 AND BUILDING 509. MATCH EXISTING STRIPING,
CONFIGURATION, AND COLOR.
CONTRACTOR SHALL VERIFY STRIPING REQUIREMENTS/QUANTITIES
BEFORE BIDDING.
CLEAN PARKING LOT AND PREP PER MANUFACTURERS
SPECIFICATIONS PRIOR TO APPLYING PAINT STRIPING.
BLDG. 509
MATCH LINE - SEE SHEET C101
GRAPHIC SCALE
( IN FEET )
020 10 20 40
1" = 20'-0"
N
SEE DETAIL - SHEET C105
SEE DETAIL - SHEET C103
21 NEW SMOKING SHELTER ON 12'-0" X 20'-4" X 6" CONCRETE PAD
COORDINATE ACTUAL PAD SIZE WITH SMOKE SHELTER MANUFACTURER.
BLDG. 503
BLDG. 503 H
VAN POOL
PARKING ONLY
E X
TE
R
IO
R
U P
G R
A D
E B
U
IL
D
IN
G
S
IT
E P
LA
N
(N
O R
TH
R
EP
A
IR
/M
IN
O R C
O N
ST
VAN POOL
PARKING ONLY
VAN POOL
PARKING ONLY
VAN POOL
PARKING ONLY
MOTORCYCLE
PARKING
TRAFFIC LIGHT POLE
LIGHT POLE
FRONT TIRE
FIRE LANE
TELEPHONE POLE
LIGHT POLE
BLDG.
FURNISH & INSTALL L4"x4"x3/8"
HEIGHT OF WALL, PRIME AND
PAINT DAKOTA BROWN. ATTACH
ANGLE WITH 1/2"x6" EPOXY
ANCHORS @ 12" O.C.
010 5 10 20
1" = 10'-0"
N
KEY NOTES
E X
TE
R
IO
R
U P
G R
A D
E (N
O R
TH
B U
IL
D
IN
G
S
IT
E P
LA
N
D
E
TA
IL
S
R
EP
A
IR
/M
IN
O R
C O
N
ST
BLDG. 501
010 5 10 20
1" = 10'-0"
N
NEW 4' SIDEWALK
WITH CURB WALLS
PAINT CURB RED TO 15'
NORTH AND SOUTH OF
FIRE HYDRANT
INSTALL NEW
HANDICAPPED
RAMP, WITH CURB
WALL. DOME
COLOR: GRAYNEW PACER
PROTECT FENCE
NEW 6' SIDEWALK
8 NEW 4' SIDEWALK
EXISTING GATE 37P HARDWARE TO BE
IDENTICAL TO GATE 36P
REQUIREMENTS AS SPECIFIED ON C105
SAWCUT AND REMOVE EXISTING ASPHALT
AND CURB & GUTTER AS REQUIRED.
INSTALL NEW CONCRETE WITH CURB WALL,
MATCH EXISTING ASPHALT ELEVATION
NEW CURB
WALL
E X
TE
R
IO
R
U P
G R
A D
E (N
O R
TH
B U
IL
D
IN
G
S
IT
E P
LA
N
D
E
TA
IL
S
R
EP
A
IR
/M
IN
O R
C O
N
ST
.2
6'
7.
.0 0'
.6
0' 6.
7.
15.21'
21.21'
6.00'
1.00'
16.00'
1.00'
.4
9' 5.
16.69' 5.52'1.15'
BLDG. 503A
INSTALL GALVANIZED "C" CHANNEL
12" THICK WALL - C15x33.9 8" THICK WALL - C10x15.3
CONTRACTOR TO VERIFY WALL THICKNESS,
ATTACH CHANNEL WITH 1/2"x6" EPOXY
ANCHORS @ 12" O.C.
010 5 10 20
1" = 10'-0"
N
4" PVC DRAIN PIPE TEE INTO
EXISTING BLOWOFF LINE
1 7
SAWCUT AND REMOVE EXISTING CURB & GUTTER AND
SIDEWALK. INSTALL NEW CURB & GUTTER AND CONCRETE
APRON, DRAINING TO NEW 2' X 2' CATCH BASIN.
GATE 36P - REMOVE EXISTING GATE POST.
INSTALL NEW 6" DIA. CONCRETE FILLED POST.
DESIGN HINGES FOR 5000 USES PER DAY. MAN
GATE TO HAVE AUTOMATIC CLOSURE SYSTEM
FOR THIS HEAVY USE E.G. INGERSOLL RAND OR
EQUIVALENT. CONTRACTOR TO SUBMIT
PROPOSED SYSTEM FOR APPROVAL BY
ENGINEER AND GOVERNMENT. SET GATE
OPENING PRESSURE TO 15 LBF.
CONTRACTOR: TO PROVIDE SPARE HINGE AND
CLOSURE ASSEMBLIES
REMOVE EXISTING
FENCE CONTROLS
AND PHONE
SEE ELEC. DWG.
EXISTING SD
INLET
CUT PIPE FLUSH
TO PAVEMENT
(APPX. LOCATION)
CONTROL PANEL
FOR GATE ACCESS
SEE ELECTRICAL
PLANS
DEMO EXISTING FENCE
NEW GATE
E X
TE
R
IO
R
U P
G R
A D
E
B U
IL
D
IN
G
S
IT
E P
LA
N
D
E
TA
IL
S
R
EP
A
IR
/M
IN
O R
C O
N
ST
CONNECT TO EXISTING
18" RCP
REPLACE
PEDESTRIAN
STRIPING TO
CENTER ON NEW
HANDICAP RAMP.
REMOVE CROSSWALK
STRIPING FROM EXISTING
PAVEMENT.
EXISTING BLOW-OFF LINE
CUT IN 2 METER (6.56') LONG ACO
K100S TRENCH DRAIN TO ALLEVIATE
WATER PONDING SEE DETAIL 7/C501
RIVER ROCK
1.0 % MIN.
1.5 % MIN.
SEE CURB DETAIL 2/501
1.3 % MIN.
BLDG. 503A
BLDG. 503
R1.00'
DOME COLOR: GRAY
EX
TE
RI
OR
U
PG
RA
DE
BU
ILD
IN
G
SI
TE
D
ET
AI
LS
C501
R
EP
A
IR
/M
IN
O R
C O
N
ST
EX
TE
RI
OR
U
PG
RA
DE
BU
ILD
IN
G
SI
TE
D
ET
AI
LS
C502
R
EP
A
IR
/M
IN
O R C
O N
ST
GEOTEXTILE FABRIC, MIRAFI
140N OR EQUAL
CONCRETE BLOCK TO SUPPORT
RINGS
GRADED ROCK, 2" MINUS
C.I. STEPS @ 12" O.C.
STANDARD OFFSET CONE SECTION
NATIVE EXCAVATED SOIL,
COMPACTED IN 6" LAYERS
INSTALL ONE 6" GRADE RING
4 FOOT PERFORATED SECTIONS WITH
1" DIAMETER PERFORATIONS, SPACED
@ 12" O.C. BOTH DIRECTIONS
DO NOT MORTAR JOINTS
FINISHED GRADE
30" M.H. RING AND COVER
(A-1180 D&L SUPPLY CO. OR EQUAL)
TOPSOIL AND SOD PER LANDSCAPE PLANS
1'-10"
2'- 0"
3'- 0"
3'-0"
4" (TYP.)
COLOR: WHITE
FED. STD. #17875
STANDARD INTERNATIONAL
SYMBOL OF ACCESSIBILITY
COLOR: LIGHT BLUE
FED. STD. #15123
HANDICAPPED SYMBOL
PAVEMENT MARKING
NONE
RA
MP
D
OW
N
EXISTING SOD
RIVER ROCK
RIVER ROCK
RIVER ROCK
FENCE
55±
GRAPHIC SCALE
( IN FEET )
030 15 30 60
1" = 30'-0"
N
EX
TE
RI
OR
U
PG
RA
DE
BU
ILD
IN
G
LA
ND
SC
AP
IN
G
AN
D
PL
AN
TI
NG
P
LA
N
LS-101
R
EP
A
IR
/M
IN
O R C
O N
SCALE:
U
IL
D
IN
G
NOTES:
1. REPLACE BROKEN WINDOW IN GUARD SHACK
2. INSTALL AWNING TO COVER KEY PAD. SEE DETAIL A1/A501.
3. REMOVE FENCE BETWEEN MAIN FENCE AND GUARD SHACK. RELOCATE PHONE TO
MAIN FENCE.
4. INSTALL PAINTED STEEL AWNING OVER ENTRY AS SHOWN. ROOF TO BE STANDING
SEAM METAL.
5. REPLACE DOOR SWEEPS AND SEALS. CAULK AS REQUIRED TO PREVENT INGRESS OF
STANDING WATER. TEST TO VERIFY COMPLIANCE.
6. REPOINT EXTERIOR MASONRY AS REQUIRED, PARTICULARLY THE SOUTHWEST CORNER
OF BUILDING 503A AND BUILDING 503. MATCH COLOR TO EXISTING.
7. PROVIDE RAKE FLASHING AT EXISTING CANOPY. PRE-FINISHED METAL TO MATCH
EXISTING METAL ROOFING. SEE DETAIL A2/A501.
8. BREAK AREA CANOPY. PROVIDE 16'X24' PRE-FINISHED METAL CANOPY WITH
STANDING SEAM METAL ROOF. BASIS OF DESIGN POLYGON HIP ROOF RECTANGLE
SHADE STRUCTURE, OR EQUAL. COLOR TO MATCH DAKOTA BROWN.
9. PROVIDE VINYL COATED 5'-6"X10' PICNIC TABLES, DAKOTA BROWN, TYPICAL OF 4.
10. EMERALD MAPLE, TYP. OF 6.
11. PROVIDE SHARK GRIP MICRONIZED POLYMER MEDIA FOR AGGRESSIVE ANTI-SLIP AT ALL
EXTERIOR STAIRS. GENERAL CONTRACTOR TO VERIFY QUANTITY AND LOCATIONS
WITH AIR FORCE REPRESENTATIVE DURING PRE-BID WALK-THROUGH.
12. NEW CANOPY EXTENSION. MATCH SLOPE AND PAINT COLOR OF EXISTING ADJACENT
CANOPY. SEE STRUCTURAL FOR FRAMING LAYOUT.
13. INSTALL RADIUSED PROTECTIVE EDGE BROWN ANODIZED ALUMINUM ANGLE AT
CORNER TO A HEIGHT OF 5'-0" ABOVE FINISH GRADE.
14. FIX CANOPY LEAKS ABOVE STAIRS. SEE NOTE 25 ON C103.
15. PROVIDE HANDRAIL ON WEST WALL OF RAMP.
16. PROVIDE WINDOW IN DOOR. REPAIR DOOR AS REQUIRED.
NORTH
12'-0" 6'-0"
'-0
'-0
SEE 2/A101 FOR
CONTINUATION.
SEE CIVIL SHEET
C101A FOR
PARKING LOT
RE-STRIPING
(ABOVE)
ABOVE14
LINE
MATCH
LINE
MATCH
SEE 1/A101 FOR
CONTINUATION.
IL
D
IN
G
NOTES:
1. PRESSURE WASH BUILDING 503H TO REMOVE ACCUMULATED OIL FILM. PROVIDE
WASH AND SAFETY PLAN PRIOR TO COMMENCEMENT OF WORK FOR APPROVAL.
2. PROVIDE POWERED DOOR OPENER FOR MAN DOOR.
3. PROVIDE POWERED DOOR OPENER FOR OVERHEAD DOOR WITH INDUSTRIAL GRADE
METALLIC ENCLOSURE.
4. REPLACE DOOR SWEEPS AND SEALS. CAULK AS REQUIRED TO PREVENT INGRESS OF
STANDING WATER. TEST TO VERIFY COMPLIANCE.
5. PROVIDE (4) BOLLARDS AROUND EXISTING TRANSFORMER. SEE DETAIL B1/A501
6. PROVIDE CONCRETE PAVING FOR FORKLIFT ACCESS. REMOVE EXISTING COBBLES,
REMOVE EXISTING CURB. ALIGN CONCRETE WITH EXTERIOR DOORS ON SECOND
FLOOR.
7. PROVIDE (2) BOLLARDS AROUND EXISTING EQUIPMENT. INSTALL ON SOUTHEAST
AND SOUTHWEST CORNERS. SEE DETAIL B1/A501.
8. PROVIDE VINYL STRIP CURTAIN AT OVERHEAD DOOR.
9. REPLACE EXISTING THRESHOLD WITH PEMKO 1665A THRESHOLD. REPLACE ALL
DOOR HARDWARE, MATCH EXISTING. NEW HARDWARE TO BE HEAVY DUTY
COMMERCIAL GRADE. E.G. INGERSOLL RAND OR EQUIVALENT.
10. PROVIDE SHARK GRIP MICRONIZED POLYMER MEDIA FOR AGGRESSIVE ANTI-SLIP AT
ALL EXTERIOR STAIRS. GENERAL CONTRACTOR TO VERIFY QUANTITY AND
LOCATIONS WITH AIR FORCE REPRESENTATIVE DURING PRE-BID WALK-THROUGH.
11. PROVIDE NEW DOOR FRAME TO REPLACE EXISTING DOOR FRAME. GROUT IN PLACE
12. GENERAL CONTRACTOR STAGING AREA NORTH OF ROADWAY. VERIFY LOCATION
WITH AIR FORCE REPRESENTATIVE.
13. AUGMENT/REPAIR EXISTING BIRD SCREEN ENCLOSING TO IMPROVE EFFECTIVENESS.
EXTEND EXISTING SCREENING TO EAST AND TO SOUTH TO TOTALLY ENCLOSE
PIPING AND CUL DE SAC. PRESSURE WASH CONTAMINATED AREAS. PROVIDE
ULTRASONIC REPELLER AT EAST END OF RAMP IDENTICAL TO EXISTING UNIT AT
MAIN ENTRY WAY. CLEAN ENTIRE NORTH DOCK WALL TO REMOVE DIRT, CARBON,
RUBBER ETC. STAINING
14. MODIFY DOCK LEVELER TO ENSURE FLUSH SURFACE. RE-EPOXY AS REQUIRED.
15. PROVIDE NEW METAL STAIRWAY FROM CONCRETE GRADE LEVEL TO DOCK SURFACE.
STAIRWAY TO BE VIRTUALLY IDENTICAL TO EXISTING METAL STAIRWAY ON EAST
SIDE OF DOCK.
16. EXTEND EXHAUST DUCTING TO ABOVE ROOF LINE. DESIGN TO COMPLY W/ EXISTING
ACGIH REQUIREMENTS. POWER AVAILABLE @ PNL 4 IN 503.
NORTH
32'16'12' 8' 4' 0 16'8'
8 3
2 2
9 11 9
ROADWAY
13 13
SCALE:
N
BUILDING 503A
SCALE:
N
BUILDING 503A
B U
IL
D
IN
G
BLACK AND YELLOW PAINT STRIPING. MATCH
EXISTING STRIPING. COORDINATE FINAL
LOCATION/EXTENTS WITH OWNER.
FLOOR PAINT LEGEND
WHITE AND GREEN PAINT STRIPING AT
EYEWASH. MATCH EXISTING STRIPING.
COORDINATE FINAL LOCATION/EXTENTS
WITH OWNER.
PAINT STAIRWAY. PROVIDE SHARK GRIP
MICRONIZED POLYMER MEDIA FOR
AGGRESSIVE ANTI-SLIP ON TREADS. GENERAL
CONTRACTOR TO VERIFY QUANTITY AND
LOCATIONS WITH AIR FORCE REPRESENTATIVE
DURING PRE-BID WALK-THROUGH.
NORTH
NOTES:
1. PAINT STRIPING AT DOOR OPENING. SEE
LEGEND FOR COLOR.
1 1 1
IL
D
IN
G
3'-4"
3'-0"
STANDING SEAM
METAL ROOF,
ON METAL
DECK. COLOR:
DAKOTA BROWN
4" x 4" x 1/4"
TUBE STEEL,
TYP.
NOTE:
ALL EXPOSED STEEL
TO BE PRIMED AND
PAINTED. COLOR:
DAKOTA BROWN.
1/4" ALUMINUM
PLATE, ATTACH TO
TUBE STEEL, USE
NEOPRENE WASHERS
TO SEPARATE
ALUMINUM AND
STEEL.
SEE ELECT. FOR
GATE CONTROLS
AND PHONE
2'-0"
SEE ELECT. FOR
GATE CONTROLS
AND PHONE.
1/4" ALUMINUM
PLATE, ATTACH
TO TUBE STEEL,
USE NEOPRENE
WASHERS TO
SEPARATE
ALUMINUM AND
STEEL.
PHONE, PERSONNEL GATE,
VEHICLE GATE
PROVIDE NAMEPLATE
WITH GATE NUMBER
AND DESCRIPTION LIGHT
CONTRACTOR TO COORDINATE ALL PHONE WORK WITH BASE
COMM. CONTACT GORDON GROTZSCI OR ROSE REESE
CONTRACTOR TO PROVIDE POWER TO LIGHT AND CONDUIT
FOR PHONE CONDUCTORS
PRE-FINISHED METAL
FLASHING, COLOR TO
MATCH EXISTING
ROOF. CRIMP OVER
FIRST ADJACENT
EXISTING STANDING
SEAM.
EXISTING STANDING
SEAM ROOF AND
DECK.
EXISTING TUBE STEEL
BEYOND
CONT. GALV. CLEAT
6"x4"x3/8" STEEL
ANGLE, PAINT TO
MATCH ROOF
STRUCTURE.
VERIFY PAVING/
SLAB THICKNESS
CONCRETE
FINISHED SURFACE
30# FELT PAPER
SECTION TYP. PLACEMENT
EDGE OF SCHED.
WALL.
6" DIA. PAINTED STEEL
PIPE W/ROUNDED
TOP, FILLED WITH
CONCRETE
WALL AS SCHED.
2'-0"
3" WIDE REFLECTOR
TAPE
PRE-FINISHED METAL
FLASHING, COLOR TO
MATCH EXISTING
ROOF. CRIMP OVER
FIRST ADJACENT
EXISTING STANDING
SEAM.
NEW STANDING SEAM
ROOF AND DECK, TO
MATCH EXISTING
NEW EXISTING
OPEN TO
BELOW
EDGE OF
EXISTING
ROOF
CANOPY
EDGE OF
EXISTING
ROOF
CANOPY EXISTING
RIDGE
EXISTING
VALLEY EDGE
FACE OF EXISTING
EIFS SOFFIT
FACE OF EXISTING
MASONRY ABOVE
FACE OF EXISTING
MASONRY
EXISTING
VALLEY EDGE
EXISTING
TUBE
STEEL
NEW MEMBRANE
ROOFING IN VALLEY,
MATCH EXISTING
MATERIAL AND
SLOPE.
NEW STANDING
SEAM METAL ROOF,
MATCH EXISTING
MATERIAL, COLOR,
AND SLOPE.
SLOPE DOWN
SL
O
PE
D
O W
N
STANDING SEAM
METAL FLASHING,
SLOPE 1/2" PER FOOT,
MIN.
EXISTING PARAPET
NEW EXISTING
SLOPE DOWN
FASTEN TO EXISTING
FLASHING W/
NEOPRENE BACKED
WASHERS @ 12" O.C.
NEW CANOPY
STRUCTURE
X
TE
R
IO
R
U P
G R
A D
E B
U
IL
D
IN
G
G E
N E
R A
L S
TR
U
C
TU
R A
L N
O
TE
S
R
EP
A
IR
/M
IN
O R
C O
N
X
TE
R
IO
R
U P
G R
A D
E B
U
IL
D
IN
G
G E
N E
R A
L S
TR
U
C
TU
R A
L N
O
TE
S
R
EP
A
IR
/M
IN
O R
C O
N
7 8 9 10
H
G
F
E
D
FOUNDATION PLAN BLDG 503A
NORTHNEW CANOPY FOOTING &
7 8 9 10
H
G
F
E
D
PLAN BLDG 503A
NORTHNEW CANOPY FRAMING
FOOTING & FOUNDATION PLAN
NORTHBREAK AREA CANOPY
EXISTING ITEMS PLAN
LEGEND
FOOTING & FOUNDATION
PLAN LEGEND
ROOF FRAMING PLAN
LEGEND
E X
TE
R
IO
R
U P
G R
A D
E B
U
IL
D
IN
G
S
TR
U C
TU
R
A L
P
LA
N S
R
EP
A
IR
/M
IN
O R
C O
N
STEEL BASE PLATE AT CORNER OF
EXISTING FOUNDATION WALL - PLAN VIEW
STEEL BASE PLATE AT END OF EXISTING
FOUNDATION WALL - PLAN VIEW
STEEL BASE PLATE ON EXISTING
FOUNDATION WALL - PLAN VIEW
TYPICAL NEW STEEL COLUM ON EXISTING
CONCRETE FOUNDATION WALL
EPOXY THREADED ROD ANCHOR SCHEDULE WITH DETAIL
CONCRETE FOOTING SCHEDULE
TYPICAL STEEL COLUMN BASE
NEW STEEL PLATE CONNECTION TO
EXISTING CONCRETE WALL
TYPICAL STEEL BEAM ON STEEL COLUMN
CONNECTION
TYPICAL NEW STEEL BEAM CONNECTION TO
EXISTING CONCRETE WALL
TYPICAL STEEL BEAM TO STEEL BEAM
CONNECTION - PLAN VIEW
TYPICAL STEEL BEAM ON STEEL COLUMN
CONNECTION TYPICAL STEEL DECK AT STEEL EDGE ANGLE
E X
TE
R
IO
R
U P
G R
A D
E B
U
IL
D
IN
G
S
TR
U C
TU
R
A L
D E
TA
IL
S
R
EP
A
IR
/M
IN
O R
C O
N
EDS
RES
R
S
EDS
R E
S
RES
EXISTING LOADING DOCKEXISTING LOADING DOCK
CR
EXTEND EXHAUST DUCTING TO ABOVE ROOF LINE.
DESIGN TO COMPLY EXISTING ACGIH REQUIREMENTS.
POWER AVAILABLE @ PNL 4 IN 503.
IR
T E
IR
HC
18" RCP
| A101 |
| A102 |
| A102A |
| A501 |
| C101 A |
| C101 |
| C102 |
| C103 |
| C104 |
| C105 |
| C501 |
| C502 |
| E0.1 |
| E0.2 |
| E4.0 |
| E4.1 |
| E4.2 |
| G001 |
| G002 |
| LS-101 |
| S-001 |
| S-002 |
File details come from the government source that posted it. Updated .