EPOXY TECHNICAL DATA CS-12

AS5400 SYSTEM

ANTI-SLIP ONE STEP EPOXY

Form: GDH-1140 Rev.: 042116

.DESCRIPTION AND USES .

Rust-Oleum AS5400 System is a single-component epoxy-based anti-slip floor coating designed for use on concrete floors, aisles, walkways, stairs, areas around machinery, or doorways subject to heavy foot or light vehicle traffic, where a coarse anti-slip safety finish is desired.

It may also be used on metal stairs or other metal surfaces where safety is a concern. Its ridged profile offers aggressive anti-slip characteristics in a one-component, one-step application.

This product complies with USDA FSIS regulatory sanitation performance standards for food establishment facilities. This coating is impervious to moisture and easily cleaned and sanitized.

.APPEARANCE .

Flat, textured, anti-slip finish

.PRODUCTS .

Description One Gallon Five Gallon Safety Yellow AS5444 289378 Dunes Tan AS5471 ---- Silver Gray AS5482 289376 Tile Red AS5468 ---- Black AS5479 289377 Navy Gray AS5486 ----

.RECOMMENDED PRIMER .

For metal substrates, use 9100 System DTM Epoxy Mastic.

.PRODUCT APPLICATION .

SURFACE PREPARATION

NEW, UNCOATED CONCRETE: Remove oil, dirt, grease and other chemical contaminants by cleaning with Pure Strength 3599 Industrial Cleaner/Degreaser, detergent, or other suitable cleaner. Rinse with water. Etch concrete with 108 Cleaning & Etching Solution. Rinse thoroughly, and allow to dry.

New concrete should be allowed to cure for 30 days before application of any coating. If there is any doubt about the dryness of the concrete, conduct a test by simply placing a weighted rubber mat, plastic sheet or other nonporous material on the surface for 24 hours.

Check the underside of the mat and concrete for signs of moisture. The substrate will be darker if damp. If moisture is found, allow additional drying time (10-14 days) and repeat test. If moisture persists, the concrete surface cannot be coated.

.PRODUCT APPLICATION (cont.) .

SURFACE PREPARATION (cont.)

Very dense, nonporous or chemically treated concrete may require abrasive blasting to assure proper coating adhesion. Determine porosity by pouring one ounce of water onto the concrete. If water soaks in, the surface is porous enough for coating. If water beads up on the concrete, the surface is not porous and treatment is warranted. The presence of laitance (fine white particles) will also require abrasive blasting or abrading to assure removal.

PREVIOUSLY COATED CONCRETE: Remove loose dirt, dust and paint by sweeping or vacuum cleaning. Remove grease, oil, floor compound or wax with Pure Strength

3599 Industrial Cleaner/Degreaser. Rinse with water and allow to dry.

PREVIOUSLY COATED WITH AS5400: Clean with Pure Strength

3599 Industrial Cleaner/Degreaser. Rinse with water and allow to dry.

METAL: Remove oil, dirt, grease and other chemical contaminants by cleaning with Pure Strength 3599 Industrial Cleaner/Degreaser, detergent, or other suitable cleaner. Rinse thoroughly with water and allow to dry.

Loose rust, mill scale and deteriorated previous coatings must be removed by Hand Tool (SSPC-SP-2) or Power Tool (SSPC-SP-3) cleaning. A brush-off abrasive blast (SSPC-SP-7) may be used as an alternative to scraping and wire brushing. Heavily rusted areas may require a Commercial Grade Blast (SSPC-SP-6) to ensure maximum coating performance. Prime the surface with 9100 System DTM Epoxy Mastic (must use the 9101 Activator). Allow 16-72 hours for the system to cure. Apply the desired AS5400 System finish coat.

APPLICATION

Apply only when air and surface temperatures are between 50-100°F (10-38°) and surface is at least 5°F above dew point. Thoroughly mix contents of the can with a mechanical mixer, such as a pneumatic drill motor with a Hanson mixing blade, until mixed material assumes a uniform color and appearance. Use of a phenolic core roller, such as Rust-Oleum roller 6697005, will expose the maximum amount of anti-slip aggregate, resulting in a highly ridged, irregular profile. If this is not achieved; the coating may become slippery when wet.

TECHNICAL DATA

AS5400 SYSTEM ANTI-SLIP ONE STEP EPOXY

Form: GDH-1140 Rev.: 042116

.PRODUCT APPLICATION (cont.) .

Pour the product on the surface in a long stripe approximately 2' long and 6" wide. Roll material in one direction only, pulling material toward you in slow, straight strokes with a moderate amount of pressure. Do NOT over-roll or press down too heavily on the roller in an attempt to create a smooth appearance; this will adversely affect the creation of the appropriate ridged profile and the desired anti-slip characteristics. Roll across welds, not along them. Material applied too thickly may not properly cure. Dry time may be adversely affected by high or low temperatures or high relative humidity. Protect applications from moisture for 12 to 24 hours. Protect from heavy or extended exposure to water, oil and chemicals for 5 to 7 days.

.PRODUCT APPLICATION (cont.) .

CLEANUP

Use 160 Thinner for cleanup only. Do not thin this product.

SURFACE MAINTENANCE

Maintain a clean surface to ensure that the anti-slip safety performance is maximized.

For general purpose cleaning, use 3500 System Pure Strength Cleaner/Degreaser, detergent, or other suitable cleaner. Scrub the surface with a stiff-bristled brush, broom, or use a floor machine. Rinse with clean water and allow to dry. Periodic touch up may be necessary in heavy traffic areas.

TECHNICAL DATA

Rust-Oleum Corporation Form: GDH-1140 11 Hawthorn Parkway Phone: 877•385•8155 Rev.: 042116 Vernon Hills, Illinois 60061 www.rustoleum.com/industrial An RPM Company

.PHYSICAL PROPERTIES .

Resin Type Epoxy Ester

Pigment Type Varies with color

Solvents Xylene and Propylene Glycol Monomethyl Ether

Weight Per Gallon 12.2-13.2 lbs.

Per Liter 1.46-1.58 kg

Solids By Weight 70.9-72.4%

By Volume 48.6-49.2%

Volatile Organic Compounds Less than 340 g/l (2.8 lbs/gal)

Recommended Dry Film Thickness (DFT) Per Coat

16-20 mils (400-500µ)

Wet Film to Achieve DFT 32-40 mils (800-1,000µ)

Practical Coverage at Recommended DFT (assumes 15% material loss)

40-50 sq.ft./gal (0.98-1.23 m

/l)

NOTE: coverage will be reduced when applying over porous concrete.

Coefficient of Friction Dry: 1.17, Wet: 1.00

Dry Times at 70-80°F (21-27°C) and 50% Relative Humidity

Heavy Traffic 24 hours

Recoat Minimum of 12 hours

Shelf Life 2 years minimum.

(A partially used container may be resealed and saved for future use.)

Flash Point 81°F (27°C)

Safety Information For additional information, see SDS

Calculated values are shown and may vary slightly from the actual manufactured material.

The technical data and suggestions for use contained herein are correct to the best of our knowledge, and offered in good faith. The statements of this literature do not constitute a warranty, express, or implied, as to the performance of these products. As conditions and use of our materials are beyond our control, we can guarantee these products only to conform to our standards of quality, and our liability, if any, will be limited to replacement of defective materials. All technical information is subject to change without notice.

Other files for this federal contract opportunity

Other files attached to Bldg. 503 Repair/Minor Const/Equipment, newest first.
File Type Posted
IFB_B503_Amend_04.docx DOCX document
TECHNICAL_NOTESa.docx DOCX document
2ndSiteVistSigninSheets.pdf PDF
Bldg503_asbestos_WO53153_Repair_Exterior.xlsx XLSX spreadsheet
QA_15_NOV_16_2ND_SITE_VISITcsr1_(002).docx DOCX document
5600_System_CS23_GHD582_0516 —
503 Individual Pictures 98.pdf PDF
503 Individual Pictures 68.pdf PDF
503 Individual Pictures 95.pdf PDF
503 Individual Pictures 58.pdf PDF
503 Individual Pictures 82.pdf PDF
503 Individual Pictures 94.pdf PDF
200_Anti_Skid_Additive_CS37_GDH82_715.pdf PDF
503 Individual Pictures 96.pdf PDF
LS-102.pdf PDF
503 Individual Pictures 92.pdf PDF
A_INTRODUCTION.docx DOCX document
MaterialsEstimate.docx DOCX document
Manufdata1s.pdf PDF
503 Individual Pictures 106.pdf PDF
503 Individual Pictures 64.pdf PDF
503 Individual Pictures 102.pdf PDF
503 Individual Pictures 73.pdf PDF
503 Individual Pictures 87.pdf PDF
503 Individual Pictures 65.pdf PDF
503 Individual Pictures 55.pdf PDF
Seed_Mix.pdf PDF
503 Individual Pictures 72.pdf PDF
503 Individual Pictures 57.pdf PDF
503 Individual Pictures 109.pdf PDF
RAMP_DETAIL.pdf PDF
Photo_Notes1.docx DOCX document
503 Individual Pictures 83.pdf PDF
503 Individual Pictures 69.pdf PDF
INDsupplyQuote.pdf PDF
503 Individual Pictures 66.pdf PDF
Contractor_Questions_ _Answers_-_26_Oct_2016.pdf PDF
503 Individual Pictures 89.pdf PDF
503 Individual Pictures 91.pdf PDF
503 Individual Pictures 99.pdf PDF
503 Individual Pictures 100.pdf PDF
503 Individual Pictures 101.pdf PDF
B503_Amend_02.docx DOCX document
BLDG._503_EXTERIOR_UPGRADE_SET_sow.pdf PDF
K092001-B503_Specifications_Rev_7.25.16.docx DOCX document
Storm_Water_Pollution_Prevention_Plan_Building_680_KRSM_152043.pdf PDF
CEN-CEIE_PLAN_REVIEW_CHECKLIST.docx DOCX document
BASE_FACILITY_DESIGN_STANDARD.docx DOCX document
APPENDIX_C_MASTER_ON_or_OFF_BASE_UPDATED_March_2015.docx DOCX document
Bldg._503_Solicitation.docx DOCX document
Show all 50

Bldg. 503 Repair/Minor Const/Equipment has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

File details come from the government source that posted it. Updated .