Q and A.docx

DOCX document 1 MB Posted

Attached to
STORAGE AIDS SYSTEM FOR F35 PARTS WAREHOUSE
Solicitation number
FA488720Q0005
Issued by

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FA488720Q0005

Questions and Answers 7 July 2020

Q1: On the Present Past Performance questionnaire will you be sending these out, or do we need to?

A: The contractor is responsible for filling out sections 1, 2, and 3 and sending the completed questionnaire electronically to Dimitri Pfeifer/ dimitri.pfeifer@us.af.mil. The government will then send it out to the previous customer or agency to have them fill out sections 4 and 5.

Q2: On the present past performance questionnaire the date to return the forms is July 6th, this is before we will be submit our bids. Will you be changing this date?

A: The questionnaire will be accepted with the quote on or before the solicitation close date, 15 July 2020 at 2:00PM EDT.

Q3: Provide location (or distance from the mechanical room) where the rider reach truck will be stored.

A: There is no mechanical room for the warehouse. The electrical room is in the north east corner and the disconnect for forklift charging is to the west of the electrical room on the north wall.

Q4: Provide the voltage circuits currently in electrical panel.

A: The last page of the attached PDF has the voltage circuits for the electrical panel.

Q5: Since the reach truck will be stored inside the warehouse, is there adequate ventilation?

A: The warehouse has 2 large evap coolers on the building for air movement. The building is a warehouse that is open. There are outflow dampeners for when the evap coolers are running.

image1.emf

2019122 LAFB PEB 100% ELEC.pdf

C A

D

F

I L E

L:

\2

9\

2\ El ec

EL

EC

TR

IC

SY

M

BO

LS

S

PE

IF

TIO

N S.

d w g

/1 0/

:2

0:

Br id ge t D oy le

B Y

T

AutoCAD SHX Text

DRAWING TITLE

NUMBER

DRAWING

E001

ELECTRICAL SYMBOLS & SPECIFICATIONS

ELECTRICAL DRAWING INDEX

RESTORED TO LIKE NEW CONDITION AT NO ADDITIONAL COST TO

VARIABLES DEFINED.

OWNER, ARCHITECT OR ENGINEER.

THAT CONFORM TO UNDERWRITERS' LABORATORIES LISTINGS FOR

"THROUGH-PENETRATION FIRE STOP SYSTEMS. "THE CONTRACTOR

COMPLETE CONFORMANCE TO THE UL TO THE ARCHITECT. THE

SHALL BE PROTECTED BY MATERIALS AND INSTALLATION DETAILS

DRAWINGS SHALL BE SPECIFIC FOR EACH PENETRATION, WITH ALL

SHALL SUBMIT SHOP DRAWINGS DETAILS, FURNISHED BY THE

CONNECTIONS TO VIBRATING EQUIPMENT SUCH AS MOTORS

(MINIMUM OF 2'-0" - MAXIMUM OF 6'-0") AND

CONNECTION TO LAY-IN TYPE LIGHT FIXTURES.

4. CONDUIT SHALL BE SIZED IN ACCORDANCE WITH NATIONAL

ELECTRICAL CODE. MINIMUM SIZE SHALL BE 3/4".

FACTORY FURNISHED FIXTURE FLEX TAILS MAY BE 3/8".

5. PROVIDE EXPANSION TYPE FITTINGS FOR ALL CONDUITS

WHICH CROSS EXPANSION JOINTS.

6. OUTLET BOXES SHALL BE STEEL WITH APPROPRIATE MUD

RINGS REQUIRED FOR THE USE INTENDED.

1. ALL WIRE SHALL BE THHN/THWN OR XHHW INSULATION.

MINIMUM SIZE SHALL BE #12 AWG, COPPER.

1. DEVICES SHALL BE SPECIFICATION GRADE UNLESS NOTED

2. FOLLOWING COLOR CODING SHALL BE UTILIZED.

SPECIFICALLY NOTED OTHERWISE.

STUD WALLS OR ABOVE CEILINGS. FITTINGS SHALL BE

2. ELECTRICAL METALLIC TUBING (EMT) MAY BE USED IN

STEEL COMPRESSION OR SET SCREW TYPE WITH INSULATED

1. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT UNLESS

3. FLEXIBLE METAL CONDUIT SHALL BE UTILIZED FOR ALL

STANDARDS.

PERFORMED IN COMPLETION OF THIS PROJECT FOR A PERIOD OF

ONE (1) YEAR FROM DATE OF FINAL ACCEPTANCE OF THE WORK BY

THE OWNER. ANY DEFECTS IN MATERIAL OR WORKMANSHIP

SHALL FIELD VERIFY ACTUAL LOCATIONS WITH ARCHITECT/OWNER

DIAGRAMMATICALLY. DO NOT SCALE THE DRAWINGS. CONTRACTOR

PRIOR TO ANY ROUGH-IN.

BE INSTALLED. NOTIFY ENGINEER IMMEDIATELY OF POSSIBLE

WIRING, CONTRACTOR SHALL MAKE SUCH CHANGES WITHOUT EXTRA

OBSTRUCTIONS, AND KEEP OPENINGS AND PASSAGEWAYS CLEAR.

CONSULT GENERAL CONTRACT DRAWINGS FOR CONDITIONS

AFFECTING THIS WORK AND VERIFY SPACES IN WHICH WORK WILL

ARRANGEMENT OF INDICATED EQUIPMENT, CONDUIT, OUTLETS OR

CONDITIONS REQUIRE REASONABLE CHANGES IN LOCATIONS AND

ANY DAMAGED OR DISRUPTED CIRCUITS OR EQUIPMENT SHALL BE

EXISTING MATERIALS IN SIZE AND TYPE.

WIRE OR CABLE WHICH IS USED TO SUSPEND CEILING GRID.

DEVELOPING IN THIS PERIOD SHALL BE CORRECTED AT NO

OTHERWISE.

C. WIRING DEVICES

B. CONDUCTORS

THROAT CONNECTORS.

UNDERWRITER'S LABORATORIES APPROVAL COVERING THE PURPOSE

FOR WHICH THEY ARE USED, IN ADDITION TO MEETING ALL

REQUIREMENTS OF THE CURRENT APPLICABLE CODES AND

ELECTRICAL SPECIFICATIONS

B. THE CURRENT EDITIONS OF THE FOLLOWING INDUSTRY STANDARDS,

SPECIFICATIONS AND CODES ARE MINIMUM REQUIREMENTS:

I. GENERAL

1. NATIONAL ELECTRICAL CODE.

REGULATIONS.

II. MATERIALS

A. RACEWAY

CONTROLS FOR EQUIPMENT FURNISHED UNDER OTHER SECTIONS,

OUTLET AND JUNCTION BOXES, MOTOR STARTERS, DISCONNECT AND

D. FURNISH AND INSTALL ALL ELECTRICAL WIRING, RACEWAYS,

AS REQUIRED BY THE NATIONAL ELECTRICAL CODE.

PERPENDICULAR WITH THE BUILDING WALLS. SUPPORT CONDUIT

CEILING PLENUMS) SHALL BE ROUTED PARALLEL OR

C. ALL EXPOSED CONDUIT (INCLUDING CONDUIT INSTALLED IN

UNLESS NOTED OTHERWISE.

ACCORDANCE WITH ALL ORDINANCES AND REGULATIONS.

A. WORK SHALL BE PERFORMED BY SKILLED CRAFTSMEN IN

CONFLICT WITH PIPING, DUCTWORK, STEEL, BEAMS, OR OTHER

LOCATIONS SHALL BE CHECKED WITH OTHER TRADES TO AVOID

COORDINATED. CONDUIT, FIXTURES, AND OTHER EQUIPMENT

THE ELECTRICAL OUTLETS AND EQUIPMENT WILL BE PROPERLY

B. COOPERATE WITH OTHER TRADES SO THAT THE INSTALLATION OF

CONTRACTOR SHALL SECURE AND PAY FOR ALL NECESSARY PERMITS

AND LICENSES.

OBSTRUCTIONS.

III. EXECUTION

EXISTING OR NEW, FOR ENTIRE CONTRACT AREA.

POWER CIRCUITS, BY PANEL AND POLE NUMBERS, WHETHER

2. PLATE COLOR TO BE SELECTED BY CONTRACTING OFFICER.

277/480V, 3%%C, 4W

PHASE A BLACK

PHASE B RED

PHASE C BLUE

NEUTRAL WHITE

GROUND GREEN

120/240V, 3%%C, 3W

YELLOW

GREEN

GRAY

BROWN

ORANGE

120/208V, 3%%C, 4W

BLACK

RED

BLUE

GREEN

7. TYPE MC (METAL-CLAD) CABLE MAY BE UTILIZED WHERE

ALLOWABLE BY THE NEC AND LOCAL CODES.

CONDUIT RUN CONCEALED IN CEILING OR WALL

MAGNETIC STARTER AND CONTROLS FURNISHED AND

DISCONNECT SWITCH (HEAVY DUTY) FUSED PER EQUIPMENT

SURFACE MOUNTED PANEL. LETTER INDICATES PANEL

TELEPHONE TERMINAL BOARD (TTB) 4' X 8' X 3/4"

GROUND FAULT CIRCUIT INTERRUPTING DUPLEX RECEPTACLE

DUPLEX CONVENIENCE RECEPTACLE, +4" ABOVE COUNTER

DUPLEX CONVENIENCE RECEPTACLE, +17" UNO

#6 CU

GROUND - EXTEND AND CONNECT TO BUILDING GROUND

llll

'A'

'A'

30/3

SECURITY CARD READER

SECURITY SYSTEM CLOSED CIRCUIT

ALARM HORN WALL MOUNTED AT 80" TO

NOT APPLY DIRECTLY TO THIS JOB. ALL MOUNTING HEIGHTS SHOWN TO

THIS IS A MASTER ELECTRICAL SYMBOL SCHEDULE. ALL SYMBOLS MAY

%%UELECTRICAL SYMBOL SCHEDULE

ELECTRICAL CONNECTION OR POINT OF TERMINATION.

MAGNETIC STARTER AND CONTROLS FURNISHED BY OTHERS,

J

CENTERLINE OF DEVICE, UNLESS NOTED OTHERWISE

%%uPLEASE NOTE:

JUNCTION BOX (4" SQUARE UNO) STEEL CITY OR EQUAL.

b

DUCT SMOKE DETECTOR. EXACT LOCATION TO

SMOKE DETECTOR. CEILING MOUNTED UNO

FLUSH FLOOR DUPLEX CONVENIENCE

4-PLEX CONVENIENCE RECEPTACLE, +17" UNO

FAAP

FACP

MANUAL PULL STATION, +44" UNO

TOGGLE SWITCHES - SINGLE POLE/SINGLE THROW, THREE

%%UABBREVIATIONS

ABOVE FINISHED FLOOR

ABOVE FINISHED GRADE

CIRCUIT BREAKER

AVAILABLE FAULT CURRENT

CURRENT TRANSFORMER

DISCONNECT SW

COLD WATER BOND

EXHAUST FAN

EMPTY CONDUIT

AMPERE INTERRUPTING

ELECTRIC DRINKING

GROUND FAULT CIRCUIT

FBO

GROUND FAULT CIRCUIT

GND

G

GF

EDF

EF

EC

COPPER

DOWN

DISC

DN

CWB

CU

CIRCUIT

CONDUIT

CKT

CT

CB

AFF

ALUMINUM

A.I.C.

AL

AFG

AMPERE

AFC

PANEL

NIGHT LIGHT

NON-FUSED

SWITCH

UNDER COUNTER

SWITCHBOARD

VANDALPROOF

WATER HEATER

WEATHER-PROOF (NEMA-3R UNO)

RELOCATED

TRANSFORMER

EXISTING TO BE REMOVED

EXISTING TO BE REMOVED AND

SERVICE ENTRANCE

UNLESS NOTED OTHERWISE

XFMR

XRR

XR

WH

WP

VP

UC

UNO

SW

SWBD

PNL

SES

NF

NL

MANHOLE

LIGHTING

NEUTRAL

KILOWATT

MAIN BONDING JUMPER

KILOVOLT AMPERE

LTG

MH

MBJ

KVA

KW

WEATHER-RESISTANT

WR

ARCHITECT

ARCH

EXISTING TO REMAIN

X

GFCI

TYPICAL

TYP

KCM

MAIN DISTRIBUTION FRAME

MDF

INFORMATION TECHNOLOGY

I.T.

SECURITY PANIC BUTTON

PUSH BUTTON FOR AUTOMATIC DOOR OPENER

CR

PB

SPECIAL PURPOSE OUTLET, NEMA TYPE AS

HORN, +80" TO BOTTOM OF DEVICE UNO

%%uFIRE ALARM%%u

SPLIT WIRED RECEPTACLE, +17" UNO

NOTED. PROVIDE MATCHING CORD AND CAP AS

REQUIRED, +17" UNO

RECEPTACLE

BE DETERMINED BY CONTRACTOR PER NFPA (R

= RETURN, S = SUPPLY)

BOTTOM OF DEVICE UNO

TELEVISION CAMERA

STROBE, +80" TO BOTTOM OF DEVICE UNO

HORN/STROBE COMBINATION, +80" TO BOTTOM

OF DEVICE UNO

FIRE ALARM CONTROL PANEL (FACP)

FIRE ALARM ANNUNCIATOR PANEL (FAAP)

%%uSECURITY%%u

CEILING MOUNTED 360%%d MOTION SENSOR

CEILING MOUNTED LIGHTING FIXTURE (NUMBER INDICATES

WAY, +44" UNO

DEPTH AS REQUIRED

INSTALLED BY ELECTRICAL CONTRACTOR

CIRCUIT, CAPITAL LETTER INDICATES FIXTURE TYPE,

LOWER CASE LETTER INDICATES SWITCHING CONTROL)

TYPICAL FOR ALL LIGHT FIXTURES

TOP BACKSPLASH

OUTLET. HUBBELL # GF5362 OR EQUAL, +17" UNO

PLYWOOD OR SIZED AS SHOWN WITH A #6 CU GROUND

DESIGNATION

MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS

(NUMBERS INDICATE SWITCH AMPACITY/NUMBER OF POLES)

INSTALLED BY ELECTRICAL CONTRACTOR. NUMBER

INDICATES RECOMMENDED NEMA SIZE, VERIFY WITH

EQUIPMENT MANUFACTURER

COMBINATION FUSIBLE SWITCH AND MAGNETIC STARTER

WITH CONTROLS FURNISHED AND INSTALLED BY ELECTRICAL

CONTRACTOR. NUMBER INDICATES RECOMMENDED NEMA

SIZE, VERIFY WITH EQUIPMENT MANUFACTURER

MOTOR

FLUSH MOUNTED PANEL. LETTER INDICATES PANEL

DESIGNATION

CONDUIT TURNED UP OR TOWARDS OBSERVER. SEE

APPROPRIATE PLAN FOR CONTINUATION

CONDUIT TURNED DOWN OR AWAY FROM OBSERVER. SEE

APPROPRIATE PLAN FOR CONTINUATION

CONDUIT RUN UNDER RAISED COMPUTER FLOOR OR

UNDERGROUND.

CONDUIT STUB OUT - CAP AND MARK WITH APPROVED MARKER

CONDUIT HOME RUN TO PANEL OR AS NOTED. HASH MARKS

INDICATE QUANTITY OF CONDUCTORS. NO HASH MARKS

INDICATE TWO CONDUCTORS, PLUS GROUND(S). (NOTE:

WIRE SIZE AND CONDUIT SHOWN AT HOME RUN IS MINIMUM

SIZE FOR ENTIRE CIRCUIT: #12 MINIMUM). ALL CIRCUITS

SHALL HAVE AN INSULATED GROUND WIRE SIZED PER

N.E.C. 250.122, #12 MINIMUM. EACH ISOLATED CIRCUIT

SHALL HAVE A SEPARATE INSULATED GROUND WIRE SIZED

PER 250.122 OF THE N.E.C. AND A SEPARATE NEUTRAL.

GROUND WIRE(S) ARE NOT SHOWN ON DRAWINGS

TELEPHONE OUTLET +17" TO CENTERLINE UNO, WITH 3/4"

EC STUBBED INTO ACCESSIBLE CEILING SPACE,

DATA OUTLET +17" TO CENTERLINE UNO, WITH 3/4" EC

STUBBED INTO ACCESSIBLE CEILING SPACE

TELE/DATA COMBINATION OUTLET +17" TO CENTERLINE

UNO, WITH 3/4" CONDUIT STUBBED INTO ACCESSIBLE

CEILING SPACE

GROUND FAULT CIRCUIT INTERRUPTING DUPLEX RECEPTACLE

OUTLET MOUNTED ABOVE COUNTER. COORDINATE MOUNTING

HEIGHT WITH OWNER

SERVSWITCHBOARD

INTERRUPTER

INTERRUPTER

GROUND

KCMIL, MCM, THOUSAND

CIRCULAR MILS

CAPACITY

FURNISHED BY OWNER,

INSTALLED BY

ELECTRICAL CONTRACTOR

FOUNTAIN

ES101

ELECTRICAL SITE PLAN

ET101

ELEC. FLOOR PLAN - POWER & SPEC. SYS.

E601

ELECTRICAL ONE-LINE & PANEL SCHEDULES

EXPENSE TO THE OWNER.

CONFLICTS. WHERE INTERFERENCES WITH STRUCTURAL,

MECHANICAL OR OTHER FEATURES EXIST, OR WHERE JOB

COST TO OWNER, ARCHITECT OR ENGINEER.

AND/OR DISTURBED THEN RE-ESTABLISHED IN ANY WAY, MATCH

CIRCUITS OR EQUIPMENT UNLESS NOTED OTHERWISE ON PLANS.

MANUFACTURER OF THE FIRE STOP MATERIAL, WHICH SHOW

BE USED WHERE PRACTICAL. ANY REUSED ITEMS SHALL BE

PROPERLY SUPPORTED AND SHALL MEET ALL OTHER REQUIREMENTS

AS IF BEING FURNISHED NEW.

A. ALL MATERIALS SHALL BE NEW AND MUST CARRY THE

2. LOCAL CITY, STATE AND COUNTY CODE.

3. UNDERWRITERS LABORATORIES INCORPORATED STANDARDS.

4. NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION

5. AMERICAN STANDARDS ASSOCIATIONS.

6. AMERICANS WITH DISABILITIES ACT.

7. NATIONAL ENERGY POLICY ACT.

8. INTERNATIONAL BUILDING CODE.

9. UNIFIED FACILITIES CRITERIA.

10. UNIFIED FACILITIES GUIDE SPECIFICATIONS.

11. LUKE AIR FORCE BASE MASTER SPECIFICATIONS.

C. GUARANTEE ALL MATERIALS AND WORKMANSHIP PROVIDED OR

D. ALL ELECTRICAL CONDUIT, DEVICES AND EQUIPMENT ARE SHOWN

E. PLAN AND INSTALL WORK IN SUCH A MANNER AS TO PREVENT

F. FOR ANY EXISTING CIRCUIT THAT IS SHOWN TO BE EXTENDED

G. CONDUIT SHALL NOT BE ATTACHED TO NOR SUPPORTED BY ANY

H. CONTRACTOR SHALL NOT INTERRUPT OR REMOVE ANY EXISTING

I. ALL PENETRATIONS OF FIRE-RESISTIVE FLOORS OR SHAFT WALLS

J. CONTRACTOR SHALL FIELD VERIFY SOURCE OF ALL LIGHTING AND

K. EXISTING CONDUCTORS, CONDUIT, AND JUNCTION/PULL BOXES MAY

PEARSON

13935

R e i s t r

P o f n a l c

O

U

Z

J.

H

APPROVED PROJ. ENGR.

APPROVED CHIEF ENGR.

CHECKED BY

DRAWN BY

DATE

SCALE

PROJECT NO.

DRAWING NO.

SHEET

OF

LUKE AFB, ARIZONA

CIVIL ENGINEERING OFFICE

DEPARTMENT OF THE AIR FORCE

AIR EDUCATION TRAINING COMMAND

REV.

DESCRIPTION

BY

APPROVED

PROJECT NO:

PROJECT TITLE:

FAX (602)274-7542

PHONE (602)264-0807

PHOENIX, ARIZONA 85021

8825 N. 23RD AVENUE

ASSOCIATES

DESIGNER:

INC.

ENGINEERING

COMM. INFRASTRUCTURE

FIRE SUPPRESSION SYSTEM &

LAFB PEB

FA488719FA198

pearsonengineering@peaeng.com

LAFB BLDG 948 FIRE SUPPRESSION SYSTEM

TAUNY WOO, PE

SCOTT HINDT, EIT

XXX-XXX

11/05/19

2019122

TIME LED

MECHANICAL/HVAC

DEVELOPMENT

CONTRACTOR

20634 N. 28TH ST, #185

PHOENIX, ARIZONA 85050

PHONE (623) 312-2204

FAX (623) 312-2209

E001

NTS

BAD

LAR

ELECTRICAL SYMBOLS & SPECIFICATIONS

T1

LE

FL

PL

PO

W

ER

PE

YS

.d

KEYNOTES

ELECTRICAL FLOOR PLAN - POWER & SPECIAL SYSTEMS

NORTH

SCALE: 1/8"=1'-0"

FEET

8'

16'

1'-11"

CABINET REQUIRES 36" CLEARANCE ON

QUAD CAT6 JACK.

FURNISH & INSTALL EMCS OUTLET, TO BE

(TYP)

3/8" DIA.

8"

4"

1/4"

1"

20"

(TYPICAL)

7/16" DIA.

2"

2"

3/4"

4"

1-1/4"

12 GAUGE

STEEL

N.T.S.

#4 CU

TO SERVICE GROUND

FINISHED GRADE

BACKBOARD

3/4" FIRE RATED

EXTERNAL GROUND BUS DETAIL

FROM MH-16

12 STRAND

FIBER FROM B945

12 PAIR CU TO

STRUCTURAL

COLUMN

12 PAIR CU

SINLE MODE

RACK MOUNT 110

BLOCK

PET

110 BLOCK W/C5 CLIPS

TMGB

TELECOMMUNICATIONS WALL

TO

PET

TO

CABINET

TO MAIN

CONNECTORS

2U CABLE MANAGER

FIBER LIU W/DUPLEX SC

48 PORT CAT6 PATCH

2U CABLE MANAGER

110 BLOCK W/C5 CLIPS

POWER DISTRIBUTION

UNIT

COMM CABINET

2#10, 1#10 G, 3/4"C

SEE ONE-LINE

DIAGRAM E-601

COMM

CABINET

1-22

1-19

7'-0"

FURNISH & INSTALL NEW 36" LOCKABLE

WALL MOUNT COMM CABINET WITH FAN

ASSEMBLY KIT SIMILAR TO GREAT LAKES

GL36WM. HINGE TO BE MOUNTED ON RIGHT

SIDE, OPENING FROM THE LEFT. MOUNT

ON 3/4" FIRE RATED BACKBOARD. FIRE

STAMP MUST BE VISIBLE. CABINET SHALL

CONTAIN DEDICATED DUPLEX NEMA 5-20

RECEPTACLE, 19" RACKING, CFCI FIBER

OPTIC LIU, 110 TERMINATION BLOCKS

WITH C5 CLIPS, 48 PORT PANEL, 2U

CABLE MANAGERS, RACK MOUNT PDU. SEE

COMM CABINET DETAILS 1/E1.1 & 2/E1.1.

ONE CAT6 CABLE TERMINATED TO 568B

STANDARD ON PATCH PANEL PORT 48 ON

ONE END AND A SINGLE OUTLET

FACEPLATE NEAR THE JACE IN THE

MECHANICAL ROOM. VERIFY & COORDINATE

JACE LOCATION WITH CONTRACTING

OFFICER PRIOR TO ROUGH-IN. LABEL IN

ACCORDANCE WITH AETC FIRST 400 FEET

STANDARD GUIDANCE WITH LUKE

SUPPLEMENT.

HINGED SIDE, AND 12" CLEARANCE ON

NON-HINGED SIDES FROM ADJACENT WALLS.

QUAD CAT6 JACK ON MEZZANINE.

RECEPTACLE MOUNTED ON MEZZANINE.

ELEC. FLOOR PLAN - POWER & SPEC. SYS.

E6

LE

E-

LI

EL

HE

UL

ES

.d

ONE-LINE DIAGRAM

LOAD (VA)

%%C B

TOTAL LOAD PER PHASE

USE AND/OR AREA SERVED

PANEL

TYPE

MOUNTING

NO.

CIR

C/B

%%C A

VA

V

AMPS

USE AND/OR AREA SERVED

MAINS

NO.

CIR

%%C C

C/B

EXIST

BOLT-ON

SURFACE

120/208V, 3%%c, 4W

125A MCB

LTG - MAIN BAY

LTG - MEZZANINE/OFFICE

LTG - MAIN BAY

LTG - MECH/BATHROOM

LTG - EXIT/EMERGENCY

LTG - EXTERIOR

REC -

REC-

REC - MEZZANINE

LIGHTING CONTACTOR

IU/OU - OFFICE

SPACE

ROLL-UP DOOR (1/2HP)

ROLL-UP DOOR (1/2HP)

COMM POWER

%%UPANEL SCHEDULE LEGEND (ALL SYMBOLS MAY NOT BE USED)

EXISTING CIRCUIT BREAKER WITH LOAD

GROUND FAULT CIRCUIT INTERRUPTER TYPE CIRCUIT BREAKER

EXISTING SPARE CIRCUIT BREAKER TO REMAIN

NEW CIRCUIT BREAKER & LOAD

EXISTING CIRCUIT BREAKER & NEW LOAD

NEW CIRCUIT BREAKER & EXISTING LOAD

EXISTING CIRCUIT BREAKER & LOAD

CIRCUIT BREAKER WITH LOCKING DEVICE

SWITCH RATED TYPE 'SWD' CIRCUIT BREAKER

SHUNT TRIP TYPE CIRCUIT BREAKER

TIME CLOCK/PHOTO CELL CONTROLLED CIRCUIT

TIME CLOCK CONTROLLED CIRCUIT

GF

LO

REMOVED - TO BECOME SPARE

ARC FLASH CIRCUIT INTERRUPTER TYPE CIRCUIT BREAKER

AF

T-951

XFMR

PANEL 1, 120/208V, 3%%C, 4W, 125A

2-1/2"C

125/3

20/1

2#10, 1#10 G, 3/4"C

DASHED LINES INDICATE EXISTING TO

REMAIN. SOLID LINES INDICATE NEW.

1#1/0 BARE CU

(G)

1#500KCM, CU.,

MAIN BONDING

JUMPER

(N)

1#3/0 CU.,

METAL PIPING

SYSTEMS GROUND

#4 CU., TO

MAIN TELE/COMM

GROUND BUS

EQUIPMENT

HOUSING

1#3/0 CU.,

EQUIPMENT

BONDING

JUMPER

CONDUCTOR (20' MIN.)

#4 CU CONCRETE ENCASED

GROUNDING ELECTRODE

OR

#6 CU TO GROUNDING

ELECTRODE 3/4" DIA

X 10' LONG DRIVEN COPPER

CLAD STEEL ROD

SERVICE GROUNDING DETAIL

E-601

EQUIPMENT ENCLOSURE

MAIN BUS: MCC, PANEL, SWITCHBOARD

##/# - AMPERE TRIP SIZE,

& NUMBER OF POLES INDICATED

UTILITY SERVICE FEEDER LANDING LUG

DISTRIBUTION PANEL

MAIN LUG ONLY

DISTRIBUTION

PANEL MAIN

%%UONE-LINE DIAGRAM LEGEND (ALL SYMBOLS MAY NOT BE USED)

ACTUAL LOAD AT 125% PER CODE

CIRCUIT BREAKER HANDLE TIE.

E601

ELECTRICAL ONE-LINE & PANEL SCHEDULES