Attachment 4

1 OCTOBER 2019

APPENDIX C

FOR

PALLET RACK

AT

LUKE AFB ARIZONA

F-35 PARTS WAREHOUSE

DATE: 1 OCTOBER 2019

PREPARED BY:

___Andrew J. Huser____

ANDREW HUSER

PROJECT ENGINEER

AFLCMC/EZPAE

Table of Contents

1. General scope1
1.1. Definitions1
2. APPLICABLE DOCUMENTS1
3. REQUIREMENTS1
3.1. System description1
3.2. Physical and Performance Characteristics2
3.2.1. Configuration requirements2
3.2.2. Upright frames2
3.2.2.1. Columns2
3.2.2.2. Bearing plates2
3.2.2.3. Diagonal/horizontal bracing3
3.2.3. Shelf beams3
3.2.3.1. Connectors3
3.2.3.2. Shelf beamtocolumn safety lock4
3.2.4. Leveling shims4
3.2.5. Anchoring the structure4
3.2.6. Assembly4
3.2.7. Decking5
4. QUALITY ASSURANCE PROVISIONS8
4.1. Inspection8
4.2. Tests8

LUKE AFB – APP C - Page i General scope This appendix establishes the minimum performance, design, fabrication, installation, and test requirements for pallet rack in the F-35 Parts Warehouse, Luke AFB, Arizona. The work shall be completed in accordance with this appendix, the Cover Purchase Description (PD), and Air Force Figure 1 and 5. This appendix covers all equipment, materials, and labor necessary to complete installation of the system.

Definitions Bay A storage location in the pallet rack which measures from the front shelf beam to the back shelf beam in depth, and from the inside of the upright frame to the inside of the opposite upright frame in width, and from the top of the shelf beam to the bottom of the next shelf beam above in height. The positions on the top level are considered bays even though they are not fully enclosed.

Decking A wire mesh surface spanning the area between two parallel shelf beams for the storage of loose or boxed items.

Pallet rack unit A unit is an assembly of two upright frames and all shelf beams joining those two upright frames; decking and tire supports.

APPLICABLE DOCUMENTS

Applicable documents shall be in accordance with Section 2 of the Cover PD.

REQUIREMENTS

System description The pallet racks will be used to store small, medium and larger sized loads and loose items in such a manner to permit placement and removal of any individual load without disturbing any other load. Wire decking shall be provided to facilitate storage of loose or boxed items. Type B48144 pallet rack shall be capable of supporting a minimum uniformly distributed load of 6,000 pounds per bay and shall be 48 inches deep with 144 inch long load beams. Type C3672 and D4872 shall be capable of supporting a minimum uniformly distributed load of 1,100 pounds per bay and shall be 36 inch and 48 inches deep, respectively, with 72 inch long load beams. The pallet rack system shall be designed to withstand the seismic conditions called for in the International Building Code for the Luke AFB Arizona locality. The pallet rack shall conform to the requirements of the latest Rack Manufacturers Institute (RMI) Specification for the Design, Testing, and Utilization of Industrial Steel Storage Racks.

Physical and Performance Characteristics Configuration requirements The pallet rack units shall be located as shown in Figure 1 (Cover PD) and configured as shown in Figures 5 and 6. The racks shall be capable of being assembled sidebyside, in a row, using common uprights to support the shelf beams.

Upright frames The upright frames shall be of steel, all welded construction consisting of two columns, diagonal and horizontal braces, and floor bearing plates. Each upright frame shall be capable of supporting fully loaded bays without permanent deformation. The upright frames of like racks shall be interchangeable. Type B48144 upright frames shall have a 18,000 pound capacity. Type C3672 and D4872 upright frames shall have 5,500 pound capacity. All types shall have a safety factor of 1.92 to 1.

Columns The columns shall be a continuous channel, box channel, rectangular, square or other formation approved by the Contracting Officer or designated representative (CODR). Each column shall have openings to readily accommodate beam connectors, end-to-end, at corresponding heights through the height range of the column openings. The openings at the bottom shall allow for the tops of shelf beams to be installed at six inches above the ground and shall continue upward to the top of the column by 2 inch increments. The arrangement of the openings and the fastening devices of the beams shall be such that the tops of the beams are flush, within 3/8 inch, with the top of the column. The width of the column, facing the aisle, shall be a minimum 2-7/8 inches for Type B and minimum 1-7/8 inches for Types C and D.

Bearing plates The bottom of each column shall have a load bearing plate securely attached. Each bearing plate shall be sufficiently sized to disperse the maximum load imposed by the column. Each bearing plate shall have a minimum of two punched holes to accept minimum 1/2-inch anchor bolts in accordance with 3.2.6.

Diagonal/horizontal bracing The columns shall be braced by horizontal and diagonal braces. Each end of all braces shall be securely welded to the columns. The braces shall not protrude beyond the sides of the columns or obstruct the attachment of the shelf beams to the columns, at any height on the columns. The centerline of the bottom horizontal brace shall not be located more than 12 inches from the bottom of the upright frame, and the centerline of the top horizontal brace shall be located not farther than 12 inches from the top of the upright frame. Other diagonal and horizontal braces shall be uniformly spaced between the top and bottom horizontal braces.

Shelf beams Shelf beams shall be the box or step type. Any openings in the shelf beam construction shall face inward, they shall not face the aisle. The connector shall not be welded to the column. Shelf beamtocolumn connection shall be of the locking type. Each pair of Type B shelf beams shall provide a bay width of 144 inches. Each pair of Type C and D shelf beams shall provide a bay width of 72 inches. With the specified uniformly distributed load per bay, there shall be no permanent deformations, and elastic deflections shall not exceed 0.56 percent of the unsupported span, measured with respect to the two ends of the beam. Shelf beam capacity for Type B is 6,000 pounds; shelf beam capacity for Types C and D is 1,100 pounds. One shelf beam, facing the aisle, per set of uprights, shall be marked identifying the shelf beam capacity (paper labels are not acceptable). Shelf beams shall be designed with a minimum safety factor of 1.65 to 1. The bottom beam of Type C and D rack shall be an inverted load beam.

Connectors Each end of the shelf beams shall have a multiple prong slipfit or slipjoint type shelf beamtocolumn connector. Separate shelf beams and connectors are unacceptable. The connectors shall be adjustable, allowing the shelf beams to be moved with no more than the use of a soft hammer. The connector shall be capable of transferring all loads and external forces of the shelf beam to the column without failure of the connection, or damage to the column or connector. The prongs shall be of sufficient number, size, and strength to withstand repeated loading and unloading of the rack, and to continually sustain the rated shelf beam load. The prongs shall engage with the openings of the columns in such a manner to prevent lateral rotation of the beam, with each prong contributing to the support of the beam. The prongs shall engage with the openings of the columns to ensure a snug metaltometal fit between the horizontal and vertical load carrying members. The prongs shall be of the same design as the opening. The bottom load beam of Type T pallet rack shall have the connector inverted such that the load beam can be configured closer to the floor.

Shelf beamtocolumn safety lock Each shelf beamtocolumn connection shall have a safety lock which shall lock the shelf beam to the column. The design and manner of construction of the device shall prevent accidental disengagement of the shelf beamtocolumn connection during movement or shifting of the assembled rack unit due to impact to the upright frame or shelf beam from horizontal or vertical directions. The safety locking device shall be an integral, attached part of the shelf beam. The safety lock shall be employed without the use of tools, and no part thereof shall obstruct or restrict the loading or unloading of the racks.

Leveling shims Leveling shims shall be provided with the rack units where necessary. The shims shall have holes corresponding to the holes in the bearing plate, and shall anchor or lock with the bearing plate when the rack is erected. Shims shall be equal in width and length to the bearing plate under which it is installed. Shims shall be of varying thickness so no more than five shims are installed at any point. Slotted shims shall be unacceptable.

Anchoring the structure The rack system shall be anchored to resist all design shear and uplift forces. The rack units shall be designed to be a rigid freestanding structure and shall not be connected to any existing building structure except the floor and mezzanine. Each bearing plate (Type B) shall be securely anchored to the floor with minimum one 1/2-inch diameter anchor bolt. Type C and D shall be anchored to the mezzanine flooring/B-Deck. The minimum embedment of the anchor for Type B shall be in accordance with 3.3.2.3 of the Cover PD.

Assembly The assembled pallet rack system shall be rigid, stable, and without deformation or skewing when each bay is loaded to the capacity of the design loads. The pallet rack system shall assemble so that the columns are perpendicular to the beams and parallel to each other. Shelf frames shall be straight and square. All horizontal members shall be level to within 1/8 inch per 10 feet measured over any distance in the rack system.

Decking Wire mesh decking shall be installed in all bays between all parallel shelf beams. The decking shall be heavy duty welded steel wire with integral support channels capable of supporting a uniformly distributed load of 1,100 pounds per bay (Type C and D), and 6,000 pounds per bay (Type B). The decking shall be designed with a minimum safety factor of 1.65 to 1. The decking shall not exhibit permanent deformation and elastic deformations shall not exceed 0.56 percent of the unsupported span. Decking shall be R-Mark compliant. The decking shall be plated or galvanized to protect against corrosion. Decking shall be the appropriate type to interface with the type shelf beam being provided. The ends of the wire mesh decking shall bend over the shelf beam to provide a secure load supporting deck and keep the decking from accidentally disengaging from the shelf beams.

FIGURE 5

FIGURE 6

QUALITY ASSURANCE PROVISIONS

Inspection The system shall be inspected to verify that it meets all the requirements of sections 1, 2, and 3 of this appendix and the Cover PD. These inspections shall be completed as part of the system checkout test and again as a part of the quality conformance test.

Tests The following tests shall be performed on the system as part of the system checkout test and again as a part of the quality conformance test.

No.
Paragraph
Description

3.1. and 3.2.3.

Three Type C, D and B pallet bays, picked at random, shall each be loaded with 1,100 pounds (Type C and D) and 6,000 pounds (Type B) to ensure the pallet beams are set in place. The loads shall then be removed. The distance from the top of each designated shelf beam to the top of the shelf beam above it shall be measured and recorded as M1. The 6,000-pound load and 1,100-pound loads shall then be put back into the designated pallet bays. The loads shall be left for a minimum of four continuous hours. The distance from the designated shelf beams to the top of the next shelf beam shall be measured again and recorded as M2. The following formula shall be used to determine the deflection amount:

Deflection = [(M1 - M2) / Beam Width ] * 100

If the deflection is greater than 0.56 or if permanent deformation exists when the loads are removed, the system shall fail.

3.2.3.2.
The shelf-to-column safety lock shall be tested at a minimum of ten random locations. Personnel shall attempt to separate empty shelf beams from the column without disabling the shelftobeam safety lock. If a shelf separates from a column then the system fails the test.
3.2.8.
Three Type C, D and B pallet rack bays, picked at random, shall each be loaded with 1,100-pounds (Type C and D) and with a 6,000 pound load (Type B) to ensure the wire decks are set in place. The loads shall then be removed. The distance from the top of each designated shelf beam to the top of the shelf beam above it shall be measured and recorded as M1. 1,100-pound loads shall then be put back into the designated pallet bays. The loads shall be left for a minimum of four continuous hours. The distance from the designated decking to the top of the decking above it shall be measured again and recorded as M2. The following formula shall be used to determine the deflection amount:

Deflection = [(M1 - M2) / Beam Width ] * 100

If the deflection is greater than 0.56 or if permanent deformation exists when the loads are removed, the system shall fail.

Offeror: _ Solicitation No. F33600- -R- _

LUKE AFB – APP C – TPQ Page 1 of 3

In-Checking Modular Office - Page 1 of LUKE AFB – APP C - Page 9 of 9

TECHNICAL QUOTE QUESTIONNAIRE

APPENDIX C

PALLET RACK

Project Title:
STORAGE AIDS SYSTEM
Base:
LUKE AFB ARIZONA

Appendix C, Pallet Rack, 1 OCTOBER 2019

This questionnaire shall be completed by the Offeror. All entries to this questionnaire shall be typed. The questionnaire will be used to determine the Offeror's understanding of the requirements and acceptability of the proposed equipment. Please attach product literature/cut sheets for all equipment detailed in this questionnaire and attach any exceptions to the Purchase Description Appendix or recommendations/design alternatives as detailed below.

Pallet Rack Manufacturer: _______________________________

Paragraph
Characteristics
3.2.1.
Dimensions:

Width of pallet rack units:

Type B:___________ inches Type C:___________ inches Type D: __________ inches Depths of pallet rack units Type B:___________ inches Type C:___________ inches Type D: __________ inches Heights of pallet rack unit:

Type B:___________ inches Type C:___________ inches Type D: __________ inches

3.2.2.
Upright frame part numbers: ________________________

Minimum capacity of upright frame:

Type B:___________ pounds Type C:___________ pounds Type D: __________ pounds based on a maximum shelf spacing of ____ inches Safety factor of: ___________________________ to 1

3.2.2.1.
Width of column facing the aisle:

Type B:___________ inches Type C:___________ inches

Vertical center-center spacing of column openings for shelf beam adjustment:___ inches

3.2.3.
Shelf beam part numbers: __________________________

Type of shelf beam: ______________________________

Bay width provided by shelf beam:

Type B:___________ inches Type C:___________ inches

Minimum capacity per bay:

Type B:___________ pounds Type C:___________ pounds Type D: __________ pounds

Safety factor of: ___________________________ to 1

Will shelf deflection meet the requirements as specified? YES NO

3.2.3.2.
Will shelf beam-to-column safety locks be provided as specified? YES NO
3.2.4
Will leveling shims be provided as specified:

YES NO

3.2.5.
Diameter of anchors to be provided:________ inches

Length of anchors to be provided: _________ inches Number of anchors per bearing plate: _____________

3.2.7.
Will wire decking be provided as specified:

YES NO

Capacity of decking:

Type B:___________ pounds Type C:___________ pounds Type D: __________ pounds

EXCEPTIONS

Attach any exceptions taken to the Purchase Description Appendix. Please outline those concerns in detail. Your exceptions will be reviewed to determine acceptability.

Are exceptions taken?

EXCEPTIONS:

LUKE AFB – APP C – TPQ Page 2 of 3 image3.wmf image1.png image2.png