This document is a comprehensive set of architectural and engineering bid documents for the City of Cocoa, Florida, detailing the remodel of the Dyal Water Treatment Plant (WTP) Operations Building located at 28400 SR 520, Christmas, Florida 32709. The project, identified as Project No. D3953000, encompasses renovations to the first floor of the existing facility, specifically targeting the Instrument Repair/Office, Breakroom, and Electrical Workshop spaces totaling approximately 3,603 square feet. The scope of work includes complete demolition and removal of existing acoustic ceiling tiles, lighting fixtures, flooring, base and wall cabinetry, appliances, and selected ductwork; installation of new 2x2 acoustical ceiling tiles and LED light fixtures; new flooring with rubber base; solid surface countertops and backsplash; new hollow metal doors and frames with hardware; partition construction using metal stud framing and gypsum board; HVAC ductwork modifications with cleaned and reinstalled air terminals; and complete electrical power and lighting distribution to support the renovated spaces. The bid documents were prepared by Jacobs Engineering and include detailed architectural, mechanical, and electrical plans with specifications for materials, finishes, and installation requirements complying with the 2023 Florida Building Code and applicable standards as of October 2025.
The bid documents establish that the design accommodates approximately 300 occupants with two exits provided and includes accessibility requirements per the 2023 Florida Accessibility Code. Materials specified include Armstrong Prelude acoustical ceiling tiles, Lambton wood doors with clear finish, Wilsonart solid surfacing for countertops, Tarkett rubber base, Florock fluid applied flooring, and Sherwin Williams paint finishes. The project includes provisions for field verification of all dimensions and existing conditions by the contractor, coordination with equipment suppliers for HVAC and electrical systems, and compliance with manufacturer's installation instructions. Specific notes indicate that contractors must investigate existing ductwork and insulation, verify all panel and circuit assignments, coordinate CAT6 cable installation for internet connectivity, and provide appropriate 24V service to dampers. The engineer contact is Joseph Margio, P.E., located at 200 S Orange Ave Suite 900, Orlando, FL 32801, and all contract documents remain the property of Jacobs with restrictions on reuse without written authorization.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTRACT DOCUMENTS
DYAL WTP OPERATIONS BUILDING REMODEL
CITY OF COCOA
FLORIDA
OCTOBER 2025
ENGINEER CONTACT:
JOSEPH MARGIO, P.E.
200 S ORANGE AVE
SUITE 900
ORLANDO, FL 32801
FOR THE
PROJECT NO. D3953000
BID DOCUMENTS
TH
IS
D O
CU
M
EN
T, A
ND
T
HE
ID
EA
S
AN
D
DE
SI
G
NS
IN
CO
RP
O
RA
TE
D
HE
RE
IN
, A
S
AN
IN
ST
RU
M
EN
T
O F
PR
O
FE
SS
IO
NA
L
SE
RV
IC
E, IS
T
HE
P
RO
PE
RT
Y O
F
JA
CO
BS
A
ND
IS
N
O T
TO
B
E
US
ED
, I
N W
HO
LE
O R
IN
P
AR
T, F O
R
AN
Y O
TH
ER
P
RO
JE
CT
W
IT
HO
UT
T
HE
W
RI
TT
EN
A
UT
HO
RI
ZA
TI
O N
O F
JA
CO
BS
JA
CO
BS
8.
A
LL
R
IG
HT
S
RE
SE
RV
ED
1 2 3 4 5 6
B
C
D
A
PROJ
DATE
DWG
VERIFY SCALE
BAR IS ONE INCH
ON ORIGINAL DRAWING.
DS
G
N
DR
CH
K
AP
VD
0 1"
RE
US
E O
F
DO
CU
M
EN
TS
File Path:
NO
DA
TE
DS
G
N
BY
AP
RV
SHEET OF 19
PLOT DATE:
DY
AL
W
TP
O
PE
RA
TI
O
NS
B
UI
LD
IN
G R
EM
O
DE
L
FL
-5
, C H
R
IS
TM
AS
, F L
C
IT
Y
O F
C O
C O
A C
O C
O A, F
LO
R
ID
A
BI
D
D O
C U
M
EN
TS
OCT 2025
D3953000
Autodesk Docs://US FL_D3953000_City of Cocoa_Dyal WTP Remodel/DWTP-JEG-ZN-10 OPERATIONS BUILDING REMODEL-ARCH_R24.rvt 9/24/2025 9:19:54 AM
AR
C
H
IT
EC
TU
R
AL
L
EG
EN
D
A N
D N
O
TE
S
01-G-003
A
DO
LS
AK
S
SL
AY
TO
N T
DO
DG
E A
DO
LS
AK
G
EN
ER
AL
ARCHITECTURAL ABBREVIATIONS ARCH/STRUCT MATERIAL SYMBOLS ARCHITECTURAL/STRUCTURAL LEGEND
GENERAL ARCHITECTURAL NOTES
A E
B
C
D
XX-A-301
1.
CONCRETE
METAL STUD WALL (PLAN)
WOOD STUD WALL (PLAN)
GYPSUM WALLBOARD
RIGID INSULATION
BATT INSULATION
ACOUSTICAL TILE
STEEL
PLYWOOD
WOOD, ROUGH NON-CONTINUOUS
WOOD, ROUGH CONTINUOUS
WOOD, FINISHED
MASONRY WALL
CMU WALL (PLAN)
CMU WALL (SECTION)
ALUMINUM
GROUT
CHECKERED PLATE
GRATING, SPAN DIRECTION INDICATED
GRANULAR FILL
EARTH OR FINISH GRADE
SYMBOL LEGEND
INDICATES PAIR OF DOORS
OR
OR
110.50
RAILINGS
DIRECTION OF SLOPE DOWN
CONTROL JOINT
EXPANSION JOINT
POST
OR
OR
A
XX101 ROOM IDENTIFIER
DOOR IDENTIFIER
WINDOW IDENTIFIER
RELIGHT IDENTIFIER
LOUVER IDENTIFIER
W-1XXW-1
XXR-1 R-1
XXL-1 L-1
INTERIOR ELEVATION INDICATOR
A
P-1 PRECAST PANEL IDENTIFIER
S-1 SIGNAGE IDENTIFIER
WALL TYPE INDICATOR
DOOR LETTER
ROOM NUMBER
F.EXT-X
HINGE SIDE
INACTIVEACTIVE
QUANTITY AND
DIRECTION OF
POINTERS AS
REQUIRED
"XX" =
FACILITY
INDICATOR
(IF SHOWN)
XX
1A
ROOM NAMEROOM NAME
FIRE EXTINGUISHER
"X" = NUMBER IN SPECIFICATIONS
SYMBOL LEGEND
HATCH SWING INDICATOR
XX
1A
(ON BRACKET)
F.EXT-X
CJ
SPOT ELEVATION INDICATOR (IN FEET)
(DOOR # ON ACTIVE)
( IN CABINET)
X" EJ
X" = DIMENSION
ELEVATION DATUM (IN FEET)
GRID / COLUMN INDICATOR
S-X
W-X
SLAB INDICATOR
COLUMN INDICATOR
WALL INDICATOR
X
ABBREVIATION
A AWNING
AC ACOUSTICAL CEILING
ACFL ACCESS FLOORING
ACMU ACOUSTICAL CMU
ACT ACOUSTICAL TILE
AJ ADJUSTABLE
AL ALUMINUM
AS AS SELECTED
BRK BRICK
BNZ BRONZE
BV BLOCK VENT
C CASEMEMT
CLR CLEAR
CLSR CLOSER
CMU CONCRETE MASONRY UNITS
CNTR COUNTER
COL COLOR
CONC CONCRETE
CONSTR CONSTRUCTION
CPT CARPET
CRC CHEMICAL-RESISTANT COATINGS
CT CERAMIC TILE
DA DUAL ACTION
DB DRAINABLE
DH DOUBLE HUNG
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EXP EXPOSED STRUCTURE
FCTY FACTORY
FNSH FINISH
FRP FIBERGLASS REINFORCED PLASTIC
FWC FABRIC WALL COVERING
FX FIXED
GALV GALVANIZED STEEL
GCMU GLAZED CONCRETE MASONRY
GH GREENHOUSE
GLZ GLAZING
GMU GLASS MASONRY UNITGRY GRAY
GSB GYPSUM SOFFIT BOARD
GWB GYPSUM BOARD
HC HOLLOW CORE
HDNR HARDENER
HGT HEIGHT
HM HOLLOW METAL
HS HORIZONTAL SLIDING
J JALOUSIE
JA JAL-AWNING
KEY KEY GROUP
KPL KICK PLATE
LD COMBINATION LOUVER/DAMPER
MATL MATERIAL
MDO MEDIUM DENSITY OVERLAY
MET METAL
MO MANUALLY OPERABLE
MS MANUFACTURER'S STANDARD
P PROJECTED
PAVT PAVER TILE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLWD PLYWOOD
PNL PANELING
PP PUSH-PULL
PTN PARTITION
QT QUARRY TILE
RESIL RESILIENT
RFS ROLL-UP FIRE SHUTTER
RRUB RADIAL RUBBER FLOORING
RUB RUBBER SHEET FLOORING
SC SOLID CORE WOOD
SIM SIMILAR
SMLS SEAMLESS EPOXY
SOI SPRAY-ON INSULATION
SP STORMPROOF
SST STAINLESS STEEL
STL STEEL
SVIN SHEET VINYL
TCTG TRAFFIC COATING
TH TOP HINGED
TR TRANSOM
TSHD THRESHOLD
TWP TRANSLUCENT PANEL SYSTEM
VCT VINYL COMPOSITION TILE
VINT VINYL TILE
VNL VINYL
VP VERTICAL PIVOTED
VS VERTICAL SLIDE
VWC VINYL WALL COVERING
WD WOOD
WHT WHITE
WRB WATER RESISTANT GWB
WS WEATHERSTRIPPING
WW WINDOW WALL
X OPEN
SYMBOL LEGENDDEFINITION
XXXX
EL XX.XX
2.
3.
4.
5.
6.
UNLESS OTHERWISE INDICATED, PLAN DIMENSIONS ARE TO COLUMN GRID ON CENTERLINES, NOMINAL SURFACE OF MASONRY, FACE OF
STUDS AND FACE OF CONCRETE WALLS.
"FINISH FLOOR" REFERS TO TOP OF CONCRETE SLABS. FINISH FLOORING IS INSTALLED ABOVE THE FLOOR LINE. FOR DEPRESSED FLOORS
AND CURBS, SEE STRUCTURAL DRAWINGS.
REPETITIVE FEATURES ARE NOT DRAWN IN THEIR ENTIRETY AND SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL.
LINES INDICATING GRADES AS SHOWN ON THE BUILDING ELEVATIONS AND SECTIONS ARE APPROXIMATE. THEY ARE AT THE BUILDING FACE, OR
ON THE SECTION END, EXCEPT AS NOTED.
VERIFY ALL ROUGH-IN DIMENSIONS FOR EQUIPMENT PROVIDED IN THIS CONTRACT, OR BY OTHERS.
REFER TO ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL AND OTHER CATEGORIES OR DRAWINGS FOR ADDITIONAL NOTES.
VERIFY SIZE AND LOCATION OF, AND PROVIDE: REQUIRED OPENINGS THROUGH FLOORS AND WALLS, ACCESS DOORS, FURRING, CURBS, ANCHORS AND INSERTS. PROVIDE ALL BASES AND BLOCKING REQUIRED FOR ACCESSORIES, MECHANICAL, ELECTRICAL AND OTHER EQUIPMENT.
7.
DUCT ACCESSORIES
DUCT FITTINGS
A. MECHANICAL DRAWINGS ARE IN PART DIAGRAMMATIC AND INTENDED TO SHOW THE SCOPE AND GENERAL ARRANGEMENT OF THE WORK UNDER THIS CONTRACT. CONTRACTOR SHALL FOLLOW THESE DRAWINGS IN LAYING OUT THE EQUIPMENT AND DUCTWORK. DRAWINGS ARE NOT INTENDED TO BE SCALED FOR ROUGHING IN MEASUREMENTS NOR TO SERVE AS SHOP DRAWINGS. WHERE JOB CONDITIONS REQUIRE MINOR CHANGES OR ADJUSTMENTS IN THE INDICATED LOCATIONS OR ARRANGEMENT OF THE WORK, SUCH
CHANGES SHALL BE MADE WITHOUT CHANGE IN THE CONTRACT AMOUNT.
B. THE CONTRACTOR SHALL VISIT THE JOB SITE TO FAMILIARIZE HIMSELF WITH ALL CONDITIONS AFFECTING THE WORK AND TO COORDINATE THE WORK WITH OTHER CONTRACTORS ON THE PROJECT. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO FABRICATION AND INSTALLATION OF DUCTWORK AND EQUIPMENT.
C. EQUIPMENT INDICATED IN THE DRAWINGS, TOGETHER WITH ITS BASE AND/OR SUPPORT, DUCTWORK, WALL, FLOOR AND ROOF OPENINGS AND ELECTRICAL SERVICE ARE BASED ON THE EQUIPMENT SCHEDULE OR SPECIFICATIONS. SHOULD CONTRACTOR SELECT AN EQUIVALENT ALTERNATE, EVEN IF APPROVED BY THE OWNER AS EQUAL, CONTRACTOR SHALL COORDINATE AND MAKE THE MODIFICATIONS IN THE WORK
WITHOUT CHANGE IN CONTRACT AMOUNT.
D. UNLESS OTHERWISE SHOWN ON DRAWINGS OR SPECIFIED HEREIN, PRODUCTS USED IN THE WORK SHALL
BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND
RECOMMENDATIONS. ANY CHANGES OR MODIFICATIONS PROPOSED BY CONTRACTOR WHICH HE BELIEVES WILL IMPROVE THE INSTALLATION SHALL BE APPROVED BY THE OWNER, OR THE OWNER'S APPROVED
REPRESENTATIVE.
E. FOR EXACT LOCATION OF CEILING MOUNTED DEVICES SUCH AS DIFFUSERS, REGISTERS, GRILLES, ETC. SEE
ARCHITECTURAL DRAWINGS.
F. ACCESS DOORS SHALL BE PROVIDED ON ALL FIRE DAMPERS, DUCT HEATING COILS, AND OTHER DEVICES AND/OR EQUIPMENT DESCRIBED ON THE SPECIFICATIONS. ACCESS DOOR SHALL BE PROVIDED WHETHER OR
NOT INDICATED ON THE DRAWING.
G. PROVIDE COMBINATION FIRE/SMOKE DAMPERS FOR ALL DUCT PENETRATIONS THROUGH TWO HOUR RATED
PARTITIONS.
H. ALL FIRE DAMPERS SHALL BE TYPE "B" UNLESS NOTED ON DRAWINGS.
I. DUCT SIZES SHOWN INDICATE INSIDE CLEAR DIMENSIONS. DUCTWORK CONNECTING TO IDUS SHALL MATCH IDU CONNECTION SIZES, BOTH RETURN AND SUPPLY. DUCTS SERVING SINGLE AIR OUTLET OR INLET DEVICE
(DIFFUSER OR GRILLE) SHALL BE SAME SIZE AS AIR DEVICE CONNECTION.
J. NOT ALL INSULATION IS SHOWN ON THE DRAWINGS.
K. COORDINATE ALL DUCTWORK LOCATIONS WITH OTHER TRADES.
L. ALL DUCTS THAT PENETRATE CHASES, WALLS OR FLOORS WHICH ARE FIRE RATED, SHALL BE INSTALLED WITH FIRE DAMPERS IN ACCORDANCE WITH NFPA 90A. THIS APPLIES EVEN IF THEY ARE NOT SPECIFICALL
SHOWN IN THE DRAWINGS.
GENERAL HVAC NOTES
ACC AIR-COOLED CHILLER
ACCU AIR-COOLED CONDENSING UNIT
ACF AIR CURTAIN FAN
AD ACCESS DOOR
A/DS AIR/DIRT SEPARATOR
AFF ABOVE FINISHED FLOOR
AFMS AIR FLOW MEASURING STATION
AFS AIR FLOW SWITCH
AHU AIR HANDLING UNIT
AP ACCESS PANEL
AS AIR SEPARATOR
ATM ATMOSPHERE
AVG AVERAGE
BF BLIND FLANGE
BFP BACKFLOW PREVENTER
BLDG BUILDING
BOD BOTTOM OF DUCT
BOP BOTTOM OF PIPE
BTM BOTTOM
CAV CONSTANT AIR VOLUME BOX
CC COOLING COIL
CD CONDENSATE DRAIN
CHWP CHILLED WATER PUMP
CL CENTERLINE
CO CARBON MONOXIDE SENSOR OR CLEAN OUT
CP CONTROL PANEL
CRU COMPUTER ROOM UNIT
CW COLD WATER
D DRAIN
DB DRY BULB TEMPERATURE
DCW DOMESTIC COLD WATER
DF DESTRATIFICATION FAN
DOAS DEDICATED OUTDOOR AIR SYSTEM
DP DEW POINT
DPR DAMPER
DN DOWN
DS DUCT SILENCER
DSD DUCT SMOKE DETECTOR
DWG DRAWING
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EF EXHAUST FAN
EG EXHAUST GRILLE
EH ELECTRIC HEATER
EL ELEVATION
ET EXPANSION TANK
ERV ENERGY RECOVERY VENTILATOR
ES EMERGENCY STOP SWITCH
ESP EXTERNAL STATIC PRESSURE
EWT ENTERING WATER TEMPERATURE
EXH EXHAUST
FCU FAN COIL UNIT
FD FIRE DAMPER OR FLOOR DRAIN
FL FLOOR
FPB FAN-POWERED BOX
FSD COMBINATION FIRE/SMOKE DAMPER
FWE FURNISHED WITH EQUIPMENT
H2 HYDROGEN MONITORING SENSOR
HOA HAND-OFF AUTOMATIC
HK HYDRO KIT
HR BRANCH SELECTOR BOX
HS HYDROGEN MONITORING SENSOR
HX HEAT EXCHANGER
IDU INDOOR AC UNIT
LVR LOUVER
LAT LEAVING AIR TEMPERATURE
LO LOCKED OPEN
LS LIMIT SWITCH
LWT LEAVING WATER TEMPERATURE
MAN MANUAL
MAU MAKE-UP AIR UNIT
MAX MAXIMUM
MCA MINIMUM CIRCUIT AMPACITY
MD MOTORIZED DAMPER
MFA MAXIMUM FUSE AMPS
MIN MINIMUM
MMF MULTIMEDIA FILTER
MOD MOTOR OPERATED DAMPER
MVD MANUAL VOLUME DAMPER
NC NORMALLY CLOSED
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NO2 NITROGEN DIOXIDE SENSOR
NTS NOT TO SCALE
OA OUTSIDE AIR
OAI OUTSIDE AIR INTAKE
OBD OPPOSED BLADE DAMPER
P PUMP
PD PRESSURE DROP
PH PENTHOUSE
PI PRESSURE INDICATION
PS PRESSURE SENSOR
PVFD POLYVINYLIDENE FLUORIDE
RA RETURN AIR
RHC REHEAT COIL
SD SMOKE DETECTOR
SD SUPPLY DIFFUSER
SF SUPPLY FAN
SL SAND LOVUER
SM SMOKE DAMPER
SP SET POINT OR SAND-LOUVERED PENTHOUSE
SS STAINLESS STEEL
T ROOM THERMOSTAT
TEFC TOTALLY ENCLOSED FAN-COOLED
TI TEMPERATURE INDICATION
TOD TOP OF DUCT
TOP TOP OF PIPE
TOS TOP OF STEEL
TOU TOP OF UNIT
TS TEMPERATURE SENSOR
UC UNDERCUT
V VENT
VAV VARIABLE VOLUME AIR BOX
VD VOLUME DAMPER
VEF VEHICLE EXHAUST FAN
VFD VARIABLE FREQUENCY DRIVE
VTA VENT TO ATMOSPHERE
VTR VENT THROUGH ROOF
VTW VENT THROUGH WALL
WB WET BULB TEMPERATURE
ABBRIEVATIONS
MOTORIZED DAMPER, MD
MANUAL VOLUME/BALANCING DAMPER
WITH LOCKING QUADRANT
FIRE DAMPER, FD
SMOKE DAMPER, SD
FIRE/SMOKE DAMPER, F/SD
AIR TERMINALS
DUCTWORK SERVICE LIST
SA SUPPLY AIR
RA RETURN AIR
EXH GENERAL EXHAUST AIR
TA TRANSFER AIR
SUPPLY AIR TERMINAL, SD-#
RETURN OR TRANSFER AIR TERMINAL, RD-# OR TD-#
EXHAUST AIR TERMINAL, EG-#
AIR TERMINAL TAG, NECK SIZE
CFM, COMMENTS
SEE SCHEDULE
SD-1, 8"⌀
350, TYP 4
SIDEWALL SUPPLY OUTLET
IN AIR FLOW
OUT AIR FLOW
RECTANGULAR MITERED 90 DEG ELBOW
RECTANGULAR 45 DEGREE DUCT TAP
RECTANGULAR TRANSITION
RECTANGULAR MITERED ELBOW, 45 DEG
RECTANGULAR RADIUS ELBOW, 45 DEG
RECTANGULAR REDUCING TEE
ROUND 45 DEG RADIUS ELBOW
ROUND DUCT CONICAL TAKEOFF
ROUND TAKEOFF SHOE
ROUND TEE
RECTANGULAR DUCT, SIZE INDICATED IS INSIDE FREE AREA
FIRST DIMENSION IS SIDE SHOWN
12x10
ROUND DUCT, SIZE INDICATED IS INSIDE FREE AREA12"ø
ROUND FLEXIBLE DUCT
ROUND TRANSITION
12"x12"
ROUND 90 DEG RADIUS ELBOW
MD-XX
LINEAR SLOT DIFFUSER, LD-#
EXPOSED ROUND SPIRAL DUCT, SIZE INDICATED IS INSIDE FREE AREA12"ø
FLAT OVAL DUCT, SIZE INDICATED IS INSIDE FREE AREA
FIRST DIMENSION IS SIDE SHOWN
12/10
RECTANGULAR TO ROUND TRANSITION
DUCT MOUNTED SMOKE DETECTORSD
FLOW SWITH TRANSMITTERFS
TEMPERATURE TRANSMITTERT
PRESSURE SENSORP
DIFFERENTIAL PRESSURE TRANSMITTERDP
T H
IS
D
O C
U M
E N
T
A N
D T
H E
I D
E A
S A
N D
D E
S
IG
N S
I N
C O
R P
O R
A T
E D
H E
R E
IN
A S
A N
I N
S T
R U
M E
N T
O F
P R
O F
E S
S
IO
N A
L S
E R
V
IC
E
IS
T
H E
P R
O P
E R
T Y
O
F J
A C
O B
S A
N D
I S
N O
T T
O B
E U
S E
D
IN
W H
O L
E O
R I N
P A
R T
F
O R
A N
Y O
T H
E R
P R
O
JE
C T
W
IT
H O
U T
T H
E W
R
IT
T E
N A
U T
H O
R
IZ
A T
IO
N
O F
J A
C O
B S
J A
C O
B S
A
L L R
IG
H
T S
R E
S E
R V
E D
1 2 3 4 5 6
B
C
D
A
PROJ
DATE
DWG
VERIFY SCALE
BAR IS ONE INCH
ON ORIGINAL DRAWING.
D S
G N
D R
C H
K A
P V
D
0 1"
R E
U S
E O
F D
O C
U M
E N
T S
File Path:
N O
D
A T
E D
S G
N B
Y A
P R
V
SHEET OF 19
PLOT DATE:
D Y
A L W
T P
O P
E R
A T
IO
N
S B
U
IL
D
IN
G R
E M
O D
E L
F
L -5
C H
R
IS
T M
A S
F
L
C
IT
Y O
F C
O C
O A
C O
C O
A
F L O
R
ID
A
B
ID
D O
C U
M E
N T
S
OCT 2025
D3953000
Autodesk Docs://US FL_D3953000_City of Cocoa_Dyal WTP Remodel/DWTP-JEG-ZN-10 OPERATIONS BUILDING REMODEL-MECH_R24.rvt
1/8" = 1'-0"
9/25/2025 2:02:39 PM
H V
A C
L E
G E
N D
01-G-004
B R
U S
S A
K
IS
J L O
P E
Z A
V A
L
IE
N T
E B
R U
S S
A K
IS
G E
N E
R A
L
DUPLEX RCPT MOUNTED IN A SINGLE GANG BOX. UNLESS INDICATED OR
DESIGNATED OTHERWISE, RCPTS ARE FLUSH MTD, 20A,125V, 1PH, 2P, 3W, NEMA
5-20R, MH 18" AFF TO CENTER
RECEPTACLE DESCRIPTIONSYMBOLS
ONE OR TWO NUMERIC DIGIT BRANCH CIRCUIT NUMBER (13 IN THIS EXAMPLE)
A
DENOTES RCPT FOR WHICH LOCATION AND MOUNTING ARRANGEMENT IS SHOWN
ON ARCHITECTURAL DRAWINGS
L6-30R
SPECIAL PURPOSE RCPT TYPE (TYPE L6-30R IN THIS EXAMPLE). SEE SPECIAL
PURPOSE RECEPTACLE SCHEDULE
WP WEATHER-RESISTANT, WEATHERPROOF WITH HINGED COVER
L PAD LOCKABLE COVER
G GFCI TYPE, WIRED FOR GFCI TRIP FOR DESIGNATED RCPT ONLY (NON-FEED-THRU
INSTALLATION)
GF
GFCI TYPE, WIRED FOR GFCI PROTECTION OF RCPT AND ALL RCPT'S DOWNSTREAM
ON SAME CIRCUIT (FEED-THRU INSTALLATION)
H50
DENOTES MOUNTING HEIGHT IN INCHES ABOVE FINISHED FLOOR TO CENTER;
50" AFF IN THIS EXAMPLE
C6
DENOTES MOUNTING HEIGHT IN INCHES ABOVE COUNTER TO CENTER; 6"
ACT IN THIS EXAMPLE
CW
DENOTES RECEPTACLE LOCATED WITHIN CASEWORK. COORDINATE LOCATION
WITH ARCHITECTURAL CASEWORK DETAILS AND VERIFY LOCATION WITH OWNER'S
REPRESENTATIVE
V VERIFY EXACT LOCATION AND HEIGHT WITH OWNER'S REPRESENTATIVE PRIOR
TO INSTALLATION
T TELECOMMUNICATION EQUIPMENT RECEPTACLE, MOUNTED 18" AFF, UNLESS
NOTED OTHERWISE
COORDINATE MOUNTING HEIGHT AND EXACT LOCATION WITH EQUIPMENT SERVED
BY RCPT, AND ALL OTHER WORK IN VICINITY OF RCPT. SEE PANEL SCHEDULE FOR
EQPT DESIGNATION
TV
TELEVISION RECEPTACLE TYPE RECEPTACLE; COORDINATE MOUNTING HEIGHT
AND EXACT LOCATION WITH OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION
NOTE: MULTIPLE RCPT DESIGNATIONS MAY BE ADJACENT TO DEVICE OR
SEPARATED BY COMMAS (EXAMPLE: A,L6-30R,13). SEE RECEPTACLE ANCILLARY
DESIGNATIONS BELOW FOR ADDITIONAL REQUIREMENTS
TWO DUPLEX (QUAD) RCPTS MOUNTED IN A TWO GANG BOX. UNLESS INDICATED
OR DESIGNATED OTHERWISE, RCPTS ARE FLUSH MTD, 20A, 125V, 1PH, 2P, 3W,
NEMA 5-20R, MH 18" AFF TO CENTER
SIMPLEX RCPT. UNLESS INDICATED OR DESIGNATED OTHERWISE, RCPTS ARE
FLUSH MTD, 20A,125V,1PH, 2P, 3W, NEMA 5-20R, MH 18" AFF TO CENTER
3 PHASE 250V SPECIAL PURPOSE RCPT, UNLESS INDICATED OTHERWISE, RCPTS
ARE FLUSH MTD, MH 48" AFF CENTER
RECEPTACLE LEGEND
WHERE INDICATED, DENOTES SURFACE MOUNTED DEVICE
P CEILING MOUNTED RCPT
SAME AS DUPLEX RCPT ABOVE, EXCEPT FED FROM BATTERY POWER SOURCE
SAME AS DUPLEX RCPT ABOVE, EXCEPT FED FROM MECHANICALLY GENERATED
POWER SOURCE
SAME AS QUAD RCPT ABOVE, EXCEPT FED FROM BATTERY POWER SOURCE
SAME AS QUAD RCPT ABOVE, EXCEPT FED FROM MECHANICALLY GENERATED
POWER SOURCE
SAME AS SIMPLEX RCPT ABOVE, EXCEPT FED FROM BATTERY POWER SOURCE
SAME AS SIMPLEX RCPT ABOVE, EXCEPT FED FROM MECHANICALLY GENERATED
POWER SOURCE
3 PHASE 480V SPECIAL PURPOSE RCPT, UNLESS INDICATED OTHERWISE, RCPTS
ARE FLUSH MTD, MH 48" AFF CENTER
RECEPTACLE ANCILLARIESDESIGNATION
RECEPTACLE TYPE AS INDICATED
WP-WIN
WEATHER-RESISTANT TYPE, WEATHERPROOF WITH WHILE-IN-USE COVER
WT WATER TIGHT TYPE RCPT
TR TAMPER RESISTANT TYPE RCPT
WR WEATHER RESISTANT TYPE RCPT
IG ISOLATED GROUNDING TYPE RCPT
SPD SURGE PROTECTIVE DEVICE TYPE RCPT
U2
5-VOLT DC, 2.1 AMP, TYPE A, USB TYPE RCPT CHARGER WITH [SIMPLEX][DUPLEX]
RCPT. NUMERIC NUMBER DENOTES QUANTITY OF USB CONNECTIONS, 2 IN THIS
EXAMPLE
5-VOLT DC, 4.2 AMP, TYPE A, USB TYPE RCPT CHARGER MOUNTED IN A SINGLE
GANG BOX, MH 18" AFF CENTER
FB
A
FLUSH FLOOR TYPE FLOOR BOX. INSTALL PER MFR INSTRUCTION. ALPHANUMERIC
DESIGNATION INDICATES FLOOR BOX TYPE, SEE FLOOR BOX SCHEDULE
PT
A
FLUSH FLOOR TYPE POKE-THRU. INSTALL PER MFR INSTRUCTION. ALPHANUMERIC
DESIGNATION INDICATES POKE-THRU TYPE, SEE POKE-THRU SCHEDULE
P A
POWER POLE, LENGTH AS REQUIRED TO EXTEND ABOVE CEILING; RCPT TYPES AS
INDICATED PER RCPT TYPE INDICATED ON ELECTRICAL DEVICE AND/OR
TELECOMMUNICATIONS LEGEND. SHADED AREA DENOTES TELECOMMUNICATION
RACEWAY. ALPHANUMERIC DESIGNATION INDICATES TYPE.
EP EXPLOSION PROOF TYPE, RATED FOR AREA CLASSIFICATION INSTALLED IN.
SWITCHING DEVICE DESCRIPTIONSYMBOLS
SWITCHING DEVICE SUBSCRIPT DESIGNATIONDESIGNATION
NOTE: WHERE SUBSCRIPT DESIGNATIONS ARE INDICATED ADJACENT TO
DEVICE, SEE SWITCHING DEVICE SUBSCRIPT DESIGNATIONS BELOW FOR
ADDITIONAL REQUIREMENTS.
WHERE USED; LOWER CASE LETTER SUBSCRIPT DENOTES FIXTURES
CONTROLLED BY SWITCH, IF NOT INDICATED BY WIRING ARRANGEMENT ON
PLANS. WHERE USED AS A DISCONNECT SWITCH, COORDINATE LOCATION AND
MOUNTING WITH RELATED EQUIPMENT; COMPLY WITH NEC AND EQUIPMENT
MANUFACTURER'S WRITTEN INSTRUCTIONS.
SWITCHING DEVICE LEGEND
TOGGLE SWITCH, SINGLE POLE, 20A, 120-277V, UNLESS DENOTED
OTHERWISE.
3 THREE WAY.
4 FOUR WAY.
EP EXPLOSION PROOF FOR THE ELECTRICAL AREA OF CLASSIFICATION
INSTALLED IN.
K KEY OPERATED WITH 2 KEYS. ALL SWITCHES KEYED ALIKE, UNLESS NOTED
OTHERWISE.
MC 3 POSITION, MOMENTARY CONTACT WITH CENTER OFF.
WP WEATHERPROOF.
M SURFACE MOUNTED MOTOR RATED WITH OVERLOAD ELEMENTS,
CONTINOUS CURRENT RATING AND QUANTITY OF POLES AS REQUIRED FOR
EQUIPMENT SERVED.
T DIGITAL TIMER WITH FLASH AND BEEP WARNING, WATTSTOPPER TS-400 OR
APPROVED EQUAL. PRESET TO 1 HOUR.
D WALL DIMMER.
WHERE INDICATED, DENOTES SURFACE MOUNTED DEVICE.
V VARIABLE SPEED CONTROL SWITCH FOR FAN, FURNISHED WITH
EQUIPMENT, UNLESS NOTED OTHERWISE.
LIGHTING LUMINAIRE DESCRIPTIONSYMBOLS
LIGHTING LEGEND
OC OCCUPANCY SENSOR [WITH MANUAL OVERRIDE].
3G
WHERE INDICATED, DENOTES SURFACE MOUNTED DEVICE.
MULTI-GANG BOX WITH MULTIPLE TOGGLE SWITCHES, SINGLE POLE, 20A,
120-277V, UNLESS DENOTED OTHERWISE. IN THIS EXAMPLE, '3G' DENOTES THREE
TOGGLE SWITCHING DEVICES MOUNTED IN A THREE GANG BOX.
3a,3b,c WHERE MULTIPLE SUBSCRIPT DESIGNATIONS ARE INDICATED, SEE SWITCHING
DEVICE SUBSCRIPT DESIGNATIONS BELOW FOR ADDITIONAL REQUIREMENTS.
DP DOUBLE POLE.
a
A
A,B
DUAL FACED ILLUMINATED EGRESS EXIT SIGN. WHERE USED, DIRECTIONAL ARROWS
AS INDICATED. WHERE WALL MOUNTED ABOVE DOOR, MOUNT BOTTOM OF FIXTURE
6" ABOVE DOOR FRAME.
SINGLE FACED ILLUMINATED EGRESS EXIT SIGN. WHERE USED, DIRECTIONAL
ARROWS AS INDICATED. WHERE WALL MOUNTED ABOVE DOOR, MOUNT BOTTOM
OF FIXTURE 6" ABOVE DOOR FRAME.
SURFACE MOUNTED LUMINAIRE. SEE LUMINAIRE ANCILLARIES BELOW FOR
ADDITIONAL REQUIREMENTS.
WALL MOUNTED EGRESS LIGHT. MOUNT 8'-0" ABOVE FINISHED FLOOR, UNLESS
INDICATED OTHERWISE. NUMBERS OF LAMP HEADS AS INDICATED IN LIGHTING
FIXTURE SCHEDULE.
WALL MOUNTED REMOTE LAMP HEAD EMERGENCY LIGHT. MOUNT 8'-0" ABOVE
FINISHED FLOOR, UNLESS INDICATED OTHERWISE. NUMBERS OF LAMP HEADS AS
INDICATED IN LIGHTING FIXTURE SCHEDULE.
LUMINAIRE ANCILLARIESSYMBOLS
WHERE INDICATED, SHADED REGION DENOTES LIFE SAFETY EGRESS.
ONE OR TWO ALPHANUMERIC CHARACTER DENOTING LUMINAIRE TYPE; SEE
LIGHTING FIXTURE SCHEDULE.
LIGHTING PANEL CIRCUIT NUMBER (3 IN THIS EXAMPLE), SEE LIGHTING PANEL
SCHEDULE. WHERE DENOTED WITH AN 'R' PREFIX (R3 FOR EXAMPLE); DENOTES
RELAY PANEL CIRCUIT NUMBER, SEE RELAY LIGHTING PANEL SCHEDULE.
WHERE LOWERCASE ALPHANUMERIC CHARACTER IS INDICATED; DENOTES
LUMINAIRE CONTROLLED BY THE CORRESPONDING LIGHT SWITCH.
WHERE INDICATED, DENOTES LUMINAIRE WIRED TO THE CORRESPONDING PHASE
CONDUCTORS.
G a
CONDUIT OR CABLE CONCEALED IN WALLS OR ABOVE CEILINGS
CONDUIT OR CABLE EXPOSED
CONDUIT OR CABLE UNDER RAISED FLOOR
LOW VOLTAGE CABLE
CONDUIT OR CABLE TURNING UP
CONDUIT OR CABLE TURNING DOWN
CONDUIT OR CABLE CHANGE IN ELEVATION
CONDUIT CAPPED
GROUNDING BUS.
SWITCH LEG CONNECTED TO SWITCH "a".
#10, 3/4"
CONDUIT OR CABLE IN SLAB OR UNDERGROUND
FEEDER CALLOUT
BRANCH CIRCUIT WIRING. #10 INDICATES AWG WIRE SIZE, AND 3/4" CONDUIT SIZE. ALL BRANCH
CIRCUIT WIRING SHALL INCLUDE A MINIMUM #12 AWG GROUND WIRE (NOT SHOWN) UON. NO
WIRING INFORMATION DENOTES 2- #12 AWG + #12 AWG GROUND IN 3/4" CONDUIT
HOMERUN TO PANELBOARD. RP1-2,4 INDICATES ORIGINATING PANEL AND
CIRCUIT NUMBERS. IF COLON IS USED BETWEEN CIRCUIT NUMBERS THEN
A MULTIPOLE CIRCUIT BKR IS DENOTED. RP1-2:4 DENOTES ORIGINATING PANEL
AND CIRCUIT NUMBERS WITH A 2-POLE BKR AT THE PANEL.
WIRING SYMBOLS LEGEND
u u
WIRING SYMBOL DESCRIPTIONSYMBOL
T H
IS
D
O C
U M
E N
T
A N
D T
H E
I D
E A
S A
N D
D E
S
IG
N S
I N
C O
R P
O R
A T
E D
H E
R E
IN
A S
A N
I N
S T
R U
M E
N T
O F
P R
O F
E S
S
IO
N A
L S
E R
V
IC
E
IS
T
H E
P R
O P
E R
J
A C
O B
S A
N D
I S
N O
T T
O B
E U
S E
D
IN
W H
O L
E O
R I N
P A
R T
F
O R
A N
Y O
T H
E R
P R
O
JE
C T
W
IT
H O
U T
T H
E W
R
IT
T E
N A
U T
H O
R
IZ
A T
IO
N
O F
J A
C O
B S
J A
C O
B S
A
L L R
IG
H
T S
R E
S E
R V
E D
1 2 3 4 5 6
B
C
D
A
PROJ
DATE
DWG
VERIFY SCALE
BAR IS ONE INCH
ON ORIGINAL DRAWING.
D S
G N
D R
C H
K A
P V
D
0 1"
R E
U S
E O
F D
O C
U M
E N
T S
File Path:
N O
D
A T
E D
S G
N B
Y A
P R
V
SHEET OF 19
PLOT DATE:
D Y
A L W
T P
O P
E R
A T
IO
N
S B
U
IL
D
IN
G R
E M
O D
E L
F
L -5
C H
R
IS
T M
A S
F
L
C
IT
Y O
F C
O C
O A
C O
C O
A
F L O
R
ID
A
B
ID
D O
C U
M E
N T
S
OCT 2025
D3953000
Autodesk Docs://US FL_D3953000_City of Cocoa_Dyal WTP Remodel/DWTP-JEG-ZN-10 OPERATIONS BUILDING REMODEL-ELEC_R24.rvt
As indicated
9/24/2025 8:49:39 AM
E L E
C T
R
IC
A L L
E G
E N
D
01-G-005
T T
W
IS
T C
H A
M M
E R
R P
E A
R L S
T E
IN
T
T W
IS
T
G E
N E
R A
L
EXISTING OPERATIONS BUILDING
PROJECT LOCATION
TH
IS
D O
CU
M
EN
T, A
ND
T
HE
ID
EA
S
AN
D
DE
SI
G
NS
IN
CO
RP
O
RA
TE
D
HE
RE
IN
, A
S
AN
IN
ST
RU
M
EN
T
O F
PR
O
FE
SS
IO
NA
L
SE
RV
IC
E, IS
T
HE
P
RO
PE
RT
Y O
F
JA
CO
BS
A
ND
IS
N
O T
TO
B
E
US
ED
, I
N W
HO
LE
O R
IN
P
AR
T, F O
R
AN
Y O
TH
ER
P
RO
JE
CT
W
IT
HO
UT
T
HE
W
RI
TT
EN
A
UT
HO
RI
ZA
TI
O N
O F
JA
CO
BS
JA
CO
BS
8.
A
LL
R
IG
HT
S
RE
SE
RV
ED
1 2 3 4 5 6
B
C
D
A
PROJ
DATE
DWG
VERIFY SCALE
BAR IS ONE INCH
ON ORIGINAL DRAWING.
DS
G
N
DR
CH
K
AP
VD
0 1"
RE
US
E O
F
DO
CU
M
EN
TS
File Path:
NO
DA
TE
DS
G
N
BY
AP
RV
SHEET OF 19
PLOT DATE:
DY
AL
W
TP
O
PE
RA
TI
O
NS
B
UI
LD
IN
G R
EM
O
DE
L
FL
-5
, C H
R
IS
TM
AS
, F L
C
IT
Y
O F
C O
C O
A C
O C
O A, F
LO
R
ID
A
BI
D
D O
C U
M
EN
TS
OCT 2025
D3953000
Autodesk Docs://US FL_D3953000_City of Cocoa_Dyal WTP Remodel/DWTP-JEG-ZN-10 OPERATIONS BUILDING REMODEL-ARCH_R24.rvt
1/8" = 1'-0"
9/24/2025 9:19:54 AM
D
YA
L W
TP
S
IT
E
LO
C
AT
IO
N P
LA
N
10-A-001
A
DO
LS
AK
S
SL
AY
TO
N T
DO
DG
E A
DO
LS
AK
AR
CH
IT
EC
TU
RA
L
1/8" = 1'-0"
SITE LOCATION PLAN
NTS
UP
A
3 4
B
C
D
ELECTRICAL
WORKSHOP
10105
BREAK
ROOM
10104
CORRIDOR
10107
JANITOR
10111
LOBBY
10110
MEN
TOILETS /
LOCKERS
10109
INSTRUMENT
REPAIR /
OFFICE
10103
SAMPLE
ROOM
10101
UNISEX
TOILET
10108
REMOVE
EXISTING
FLOOR
TILE
REMOVE
EXISTING
FLOOR TILE
REMOVE EXISTING
FLOOR TILE
REMOVE
EXISTING
CARPETING
AND FLOOR
TILE
REMOVE EXISTING
DOORS AND FRAMES
REMOVE EXISTING
DOORS AND FRAMES
REMOVE EXISTING
DOORS AND FRAME
REMOVE EXISTING
CABINETRY AND
APPLIANCES
REMOVE EXISTING
DOORS AND FRAME
LIMIT OF
FLOORING
& CEILING
REMOVAL
LIMIT OF
FLOORING
& CEILING
REMOVAL
LIMIT OF
FLOORING
& CEILING
REMOVAL
LIMIT OF
FLOORING
& CEILING
REMOVAL
LIMIT OF
FLOORING
& CEILING
REMOVAL
LIMIT OF
FLOORING
& CEILING
REMOVAL
REMOVE EXISTING
REFRIGERATOR UNITS
DEMOLISH AND REMOVE
COMMUNICATION/ELECTRICAL
EQUIPMENT CLOSET
DO NOT DISTURB
EXISTING CONDUITS
OR EXPOSED WIRING
2' - 4"
" A
10-A-101
REMOVE EXISTING
CEILING TILE AND GRID
REMOVE EXISTING
CEILING TILE
REMOVE EXISTING
CEILING TILE
REMOVE EXISTING
CEILING TILE
FAN TO BE REMOVED AND
ENCLOSED TO MATCH
EXISTING EXTERIOR
TH
IS
D O
CU
M
EN
T, A
ND
T
HE
ID
EA
S
AN
D
DE
SI
G
NS
IN
CO
RP
O
RA
TE
D
HE
RE
IN
, A
S
AN
IN
ST
RU
M
EN
T
O F
PR
O
FE
SS
IO
NA
L
SE
RV
IC
E, IS
T
HE
P
RO
PE
RT
Y O
F
JA
CO
BS
A
ND
IS
N
O T
TO
B
E
US
ED
, I
N W
HO
LE
O R
IN
P
AR
T, F O
R
AN
Y O
TH
ER
P
RO
JE
CT
W
IT
HO
UT
T
HE
W
RI
TT
EN
A
UT
HO
RI
ZA
TI
O N
O F
JA
CO
BS
JA
CO
BS
8.
A
LL
R
IG
HT
S
RE
SE
RV
ED
1 2 3 4 5 6
B
C
D
A
PROJ
DATE
DWG
VERIFY SCALE
BAR IS ONE INCH
ON ORIGINAL DRAWING.
DS
G
N
DR
CH
K
AP
VD
0 1"
RE
US
E O
F
DO
CU
M
EN
TS
File Path:
NO
DA
TE
DS
G
N
BY
AP
RV
SHEET OF 19
PLOT DATE:
DY
AL
W
TP
O
PE
RA
TI
O
NS
B
UI
LD
IN
G R
EM
O
DE
L
FL
-5
, C H
R
IS
TM
AS
, F L
C
IT
Y
O F
C O
C O
A C
O C
O A, F
LO
R
ID
A
BI
D
D O
C U
M
EN
TS
OCT 2025
D3953000
Autodesk Docs://US FL_D3953000_City of Cocoa_Dyal WTP Remodel/DWTP-JEG-ZN-10 OPERATIONS BUILDING REMODEL-ARCH_R24.rvt
As indicated
10/1/2025 9:03:10 PM
D
YA
L W
TP
D
EM
O
LI
TI
O N
P
LA
N O
PE
R
AT
IO
N S
BU
IL
D
IN
G
10-A-101
A
DO
LS
AK
S
SL
AY
TO
N T
DO
DG
E A
DO
LS
AK
AR
CH
IT
EC
TU
RA
L
1/4" = 1'-0"
DEMOLITION FLOOR PLAN
GENERAL SHEET NOTES
ELECTRICAL WORKSHOP SHALL HAVE ALL EXISTING
ACOUSTIC CEILING TILES AND LIGHTING REMOVED.
INSTRUMENT REPAIR/OFFICE AND CORRIDOR SHALL HAVE
ALL EXISTING ACOUSTIC CEILING TILES REMOVED.
EXISTING FLUORESCENT CEILING LIGHT FIXTURES ARE TO
BE REPLACED WITH NEW LED FIXTURES IN ELECTRICAL
WORKSHOP, BREAKROOM, INSTRUMENT REPAIR/OFFICE,
AND CORRIDOR.
BREAKROOM SHALL HAVE ALL EXISTING ACOUSTIC CEILING
TILES, CEILING GRID, AND LIGHTING REMOVED.
ALL EXISTING FLOORING AND FLOOR COVERINGS SHALL BE
REMOVED DOWN TO EXISTING CONCRETE SLAB.
ALL EXISTING BASE CABINETRY AND WALL CABINETRY
SHALL BE REMOVED.
LOBBY, SAMPLE ROOM, JANITOR ROOM, TOILET ROOM AND
LOCKER ROOM ARE NOT INCLUDED IN THE WORK.
ALL REMOVED CEILING TILES, LIGHTING, FLOORING,
CABINETRY, APPLIANCES, ETC. SHALL BE REMOVED FROM
THE SITE AND PROPERLY DISPOSED.
WHERE PLUMBING FIXTURES ARE REMOVED, ALL EXISTING
WATER SUPPLY PIPING AND SANITARY WASTE PIPING
SHALL BE TEMPORARILY CAPPED USING THE
APPROPRIATE FITTINGS.
FOR DESIGN CRITERIA AND ADDITIONAL INFORMATION SEE
ARCHITECTURAL GENERAL NOTES DRAWING.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
12" = 1'-0"
10-A-101
A CLOSET TO BE DEMOLISHED
LEGEND
DEMO
UP
A
3 4
B
C
D
A
10-A-301
B
10-A-301
ELECTRICAL
WORKSHOP
10105
BREAK
ROOM
10104
OFFICE
10112
CORRIDOR
10107
JANITOR
10111
LOBBY
10110
MEN
TOILETS /
LOCKERS
10109
INSTRUMENT
REPAIR /
OFFICE
10103
SAMPLE
ROOM
10101
12' - 0"12' - 0"11' - 7 1/4"
7'
3/
4"
2 2 2
3 3 3
UNISEX
TOILET
10108
OFFICE
10113
10105A
10104A
2A
3A
1A
10103B 10103A
FE-X
FE-X
91'
32"
64"
84'
77'
K1K1K1
K1
K1 K1
K1
K1
A3 A3
A3
A3 A3
1' - 10"
12' - 5 1/4" 8' - 0"
1'
1 1
10111A
10108A
10109A
3'
0"
APPLICABLE CODES AND STANDARDS
DESIGN WILL COMPLY WITH THE FOLLOWING CODES AND STANDARDS:
2023 FLORIDA BUILDING CODE (FBC) 8TH EDITION
2023 FLORIDA EXISTING BUILDING CODE (FEBC) 8TH EDITION
2023 FLORIDA MECHANICAL CODE (FMC) 8TH EDITION
2023 FLORIDA FUEL GAS CODE (FFGC) 8TH EDITION
2023 FLORIDA PLUMBING CODE (FPC) 8TH EDITION
2023 FLORIDA ACCESSIBILITY CODE (FAC) 8TH EDITION
2023 FLORIDA ENERGY CONSERVATION CODE (FECC) 8TH EDITION
2023 FLORIDA FIRE PREVENTION CODE (FFPC) 8TH EDITION
2020 NFPA 70 NATIONAL ELECTRICAL CODE (NEC)
CODE EVALUATION
OPERATIONS BUILDING
CODE REQUIREMENT
EXISTING BUILDING CODE
CLASSIFICATION
CONSTRUCTION CLASSIFICATION
OCCUPANCY CLASSIFICATION (NON-
SEPARATED)
AUTOMATIC FIRE DETECTION AND
SPRINKLER SYSTEMS
PORTABLE FIRE EXTINGUISHERS
STRUCTURAL FIRE PROTECTION
EXTERIOR WALL FIRE-RESISTANCE
RATING
REQUIRED OPENING PROTECTION
ALLOWED STORIES (S)
ALLOWED BUILDING HEIGHT (S)
MAXIMUM ALLOWED BUILDING AREA
ACTUAL AREAS
DESIGN OCCUPANT LOAD
OCCUPANT LOAD
EXITS PROVIDED / REQUIRED
EXIT WIDTH PROVIDED / REQUIRED
MAXIMUM TRAVEL DISTANCE TO EXITS
MAXIMUM COMMON PATH OF EGRESS
TRAVEL
MAXIMUM DEAD-END CORRIDOR
ACCESSIBILITY REQUIREMENTS
SPECIFIC BUILDING REQUIREMENT
TYPE II-B
FACTORY AND INDUSTRIAL, GROUP F-2
NOT REQUIRED
REQUIRED
NONE - 0 HOURS, TYPE II-B CONCTRUCTION
NONE REQUIRED FOR TYPE II-B CONSTRUCTION WITH FIRE
SEPARATION DISTANCE GREATER THAN 10 FEET
NONE REQUIRED FOR BUILDING WITH FIRE SEPARATION DISTANCE
GREATER THAN 10 FEET
2 - FOR F-2 OCCUPNCY
75 FEET
62,000 SF
3,603 SF
300 SF PER OCCUPANT
2 / 2
(1) 32” (1) 64" / 32”
300 FEET
75 FEET
25 FEET
SITE AND BUILDING ELEMENTS TO COMPLY WITH 2023 FLORIDA
BUILDING CODE, ACCESSIBILITY CODE, CHAPTER 2 REQUIRMENTS
EXCEPT AS EXEMPTED BY SECTION 203. GENERAL EXCEPTION 203.3
RASED AREAS, AREAS USED PRIMARILY FOR PURPOSES OF
OBSERVATION OR LOOKOUT GALIRIES ARE NOT REQUIRED TO
COMPLY.
EXIT TRAVEL PATH
EXIT TRAVEL DISTANCE
EGRESS WIDTH (IN INCHES)
EXIT LIGHT, ONE SIDED
EXISTING PORTABLE FIRE
EXTINGUISHER
SIGN CALL OUT
XX'
XX"
FE-X
S-X
TH
IS
D O
CU
M
EN
T, A
ND
T
HE
ID
EA
S
AN
D
DE
SI
G
NS
IN
CO
RP
O
RA
TE
D
HE
RE
IN
, A
S
AN
IN
ST
RU
M
EN
T
O F
PR
O
FE
SS
IO
NA
L
SE
RV
IC
E, IS
T
HE
P
RO
PE
RT
Y O
F
JA
CO
BS
A
ND
IS
N
O T
TO
B
E
US
ED
, I
N W
HO
LE
O R
IN
P
AR
T, F O
R
AN
Y O
TH
ER
P
RO
JE
CT
W
IT
HO
UT
T
HE
W
RI
TT
EN
A
UT
HO
RI
ZA
TI
O N
O F
JA
CO
BS
JA
CO
BS
8.
A
LL
R
IG
HT
S
RE
SE
RV
ED
1 2 3 4 5 6
B
C
D
A
PROJ
DATE
DWG
VERIFY SCALE
BAR IS ONE INCH
ON ORIGINAL DRAWING.
DS
G
N
DR
CH
K
AP
VD
0 1"
RE
US
E O
F
DO
CU
M
EN
TS
File Path:
NO
DA
TE
DS
G
N
BY
AP
RV
SHEET OF 19
PLOT DATE:
DY
AL
W
TP
O
PE
RA
TI
O
NS
B
UI
LD
IN
G R
EM
O
DE
L
FL
-5
, C H
R
IS
TM
AS
, F L
C
IT
Y
O F
C O
C O
A C
O C
O A, F
LO
R
ID
A
BI
D
D O
C U
M
EN
TS
OCT 2025
D3953000
Autodesk Docs://US FL_D3953000_City of Cocoa_Dyal WTP Remodel/DWTP-JEG-ZN-10 OPERATIONS BUILDING REMODEL-ARCH_R24.rvt
1/4" = 1'-0"
10/1/2025 9:03:10 PM
D
YA
L W
TP
O
PE
R
AT
IO
N S
BU
IL
D
IN
G L
IF
E
SA
FE
TY
P
LA
N
A N
D F
LO
O
R P
LA
N
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
10-A-201
A
DO
LS
AK
P
DE
NN
IN
G T
DO
DG
E A
DO
LS
AK
AR
CH
IT
EC
TU
RA
L
1/4" = 1'-0"
LIFE SAFETY / FLOOR PLAN
GENERAL SHEET NOTES
FOR DESIGN CRITERIA AND ADDITIONAL INFORMATION SEE
ARCHITECTURAL GENERAL NOTES DRAWING.
CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND
EXISTING CONDITIONS.
1.
2.
LEGEND
SHEET KEY NOTES
NEW FLOORING. SEE SCHEDULE.
WORK BENCH, BY OWNER.
STORAGE CABINET, BY OWNER.
SOLID SURFACE COUNTERTOPS
A
B
2 3 4
B
C
D
ELECTRICAL
WORKSHOP
10105
BREAK
ROOM
10104
OFFICE
10113
OFFICE
10112
INSTRUMENT
REPAIR /
OFFICE
10103
CORRIDOR
10107
NEW 2X2 ACOUSTICAL CEILING TILES
AND GRID
NEW 2X2 LED LIGHT FIXTURE
RELOCATED EXISTING SUPPLY AIR
TERMINAL
RELOCATED EXISTING RETURN AIR
TERMINAL
EXITING LIGHTING, ONE SIDED
EXISTING SUPPLY AIR TERMINAL
EXISTING RETURN AIR TERMINAL
REFLECTED CEILING PLAN
LEGEND
TH
IS
D O
CU
M
EN
T, A
ND
T
HE
ID
EA
S
AN
D
DE
SI
G
NS
IN
CO
RP
O
RA
TE
D
HE
RE
IN
, A
S
AN
IN
ST
RU
M
EN
T
O F
PR
O
FE
SS
IO
NA
L
SE
RV
IC
E, IS
T
HE
P
RO
PE
RT
Y O
F
JA
CO
BS
A
ND
IS
N
O T
TO
B
E
US
ED
, I
N W
HO
LE
O R
IN
P
AR
T, F O
R
AN
Y O
TH
ER
P
RO
JE
CT
W
IT
HO
UT
T
HE
W
RI
TT
EN
A
UT
HO
RI
ZA
TI
O N
O F
JA
CO
BS
JA
CO
BS
8.
A
LL
R
IG
HT
S
RE
SE
RV
ED
1 2 3 4 5 6
B
C
D
A
PROJ
DATE
DWG
VERIFY SCALE
BAR IS ONE INCH
ON ORIGINAL DRAWING.
DS
G
N
DR
CH
K
AP
VD
0 1"
RE
US
E O
F
DO
CU
M
EN
TS
File Path:
NO
DA
TE
DS
G
N
BY
AP
RV
SHEET OF 19
PLOT DATE:
DY
AL
W
TP
O
PE
RA
TI
O
NS
B
UI
LD
IN
G R
EM
O
DE
L
FL
-5
, C H
R
IS
TM
AS
, F L
C
IT
Y
O F
C O
C O
A C
O C
O A, F
LO
R
ID
A
BI
D
D O
C U
M
EN
TS
OCT 2025
D3953000
Autodesk Docs://US FL_D3953000_City of Cocoa_Dyal WTP Remodel/DWTP-JEG-ZN-10 OPERATIONS BUILDING REMODEL-ARCH_R24.rvt
1/4" = 1'-0"
10/1/2025 9:03:11 PM
D
YA
L W
TP
O
PE
R
AT
IO
N S
BU
IL
D
IN
G R
EF
LE
C
TE
D C
EI
LI
N G
P
LA
N O
PE
R
AT
IO
N S
BU
IL
D
IN
G
10-A-202
A
DO
LS
AK
P
DE
NN
IN
G T
DO
DG
E A
DO
LS
AK
AR
CH
IT
EC
TU
RA
L
1/4" = 1'-0"
REFLECTED CEILING PLAN
GENERAL SHEET NOTES
EXISTING HVAC TO BE CLEANED AND REINSTALLED IN
EXISTING LOCATIONS IN THE ELECTRICAL WORKSHOP,
INSTRUMENT REPAIR/OFFICE, AND CORRIDOR.
FIELD VERIFY QUANTITY AND LOCATIONS OF EXISTING
LIGHT FIXTURES AND HVAC. NOTIFY ARCHITECT IF THERE
ARE ANY DISCREPANCIES.
1.
2.
Slayton, Sky Rectangle
Slayton, Sky Rectangle
FIRST FLOOR
44'-0"
3' - 0" 3' - 0" 2' - 10" 1' - 6" 2' - 7 1/4" 3' - 0"
2'
6" 1'
8"
2'
3' - 0"
3' - 0" 3' - 0"1' - 6"3' - 0" 3' - 0"
1 1 1 1
FIRST FLOOR
44'-0"
3'
4"
1' - 0" 8' - 0"
6'
0'
4" 2'
3' - 0"
2 2
2' - 7" 3' - 0" 3' - 0"
2' - 1" 1' - 0"
1'
6"
2'
6"
9 1
TH
IS
D O
CU
M
EN
T, A
ND
T
HE
ID
EA
S
AN
D
DE
SI
G
NS
IN
CO
RP
O
RA
TE
D
HE
RE
IN
, A
S
AN
IN
ST
RU
M
EN
T
O F
PR
O
FE
SS
IO
NA
L
SE
RV
IC
E, IS
T
HE
P
RO
PE
RT
Y O
F
JA
CO
BS
A
ND
IS
N
O T
TO
B
E
US
ED
, I
N W
HO
LE
O R
IN
P
AR
T, F O
R
AN
Y O
TH
ER
P
RO
JE
CT
W
IT
HO
UT
T
HE
W
RI
TT
EN
A
UT
HO
RI
ZA
TI
O N
O F
JA
CO
BS
JA
CO
BS
8.
A
LL
R
IG
HT
S
RE
SE
RV
ED
1 2 3 4 5 6
B
C
D
A
PROJ
DATE
DWG
VERIFY SCALE
BAR IS ONE INCH
ON ORIGINAL DRAWING.
DS
G
N
DR
CH
K
AP
VD
0 1"
RE
US
E O
F
DO
CU
M
EN
TS
File Path:
NO
DA
TE
DS
G
N
BY
AP
RV
SHEET OF 19
PLOT DATE:
DY
AL
W
TP
O
PE
RA
TI
O
NS
B
UI
LD
IN
G R
EM
O
DE
L
FL
-5
, C H
R
IS
TM
AS
, F L
C
IT
Y
O F
C O
C O
A C
O C
O A, F
LO
R
ID
A
BI
D
D O
C U
M
EN
TS
OCT 2025
D3953000
Autodesk Docs://US FL_D3953000_City of Cocoa_Dyal WTP Remodel/DWTP-JEG-ZN-10 OPERATIONS BUILDING REMODEL-ARCH_R24.rvt
1/2" = 1'-0"
9/24/2025 9:19:55 AM
D
YA
L W
TP
O
PE
R
AT
IO
N S
BU
IL
D
IN
G
IN
TE
R
IO
R
E
LE
VA
TI
O N
S O
PE
R
AT
IO
N S
BU
IL
D
IN
G
10-A-301
A
DO
LS
AK
P
DE
NN
IN
G T
DO
DG
E A
DO
LS
AK
AR
CH
IT
EC
TU
RA
L
1/2" = 1'-0"
10-A-201
A INTERIOR ELEVATION
1/2" = 1'-0"
10-A-201
B INTERIOR ELEVATION
GENERAL SHEET NOTES
FOR DESIGN CRITERIA AND ADDITIONAL INFORMATION SEE
ARCHITECTURAL GENERAL NOTES DRAWING.
CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND
EXISTING CONDITIONS.
1.
2.
SHEET KEY NOTES
BASE CABINET WITH ONE ADJUSTABLE SHELF AND SINGLE
DRAWER
WALL CABINET WITH ONE ADJUSTABLE SHELF
LSK-2 SINK
SOLID SURFACE COUNTERTOP WITH 4" SOLID SURFACE
BACKSPLASH
DISH WASHER, BY OWNER
REFRIGERATOR, BY OWNER
ELECTRIC RANGE, BY OWNER
GUARDIAN 300B RANGE TOP FIRE SUPPRESSION SYSTEM
SOFT ADA UNDER-LAVATORY SAFETY COVER KIT. SEE
SHEET 10-A-502.
BASE 4 DRAWERS
ELECTRICAL
OUTLET
NOTES:
A VERIFY ACCESSORY SIZE WITH MANUFACTURER TO ENSURE CONFORMANCE WITH ADA MOUNTING HEIGHTS.
B DIMENSIONS TO TOILET ROOM ACCESSORIES ARE TO THE HIGHEST PORTION OF THE OPENING OR OPERATING DEVICE U.N.O.
C PROVIDE BACKING FOR INSTALLATION OF ALL WALL-MOUNTED ITEMS.
D PLACE ELECTRICAL AND TELEPHONE DEVICES AT 44 INCHES ABOVE FINISH FLOOR AT CREDENZAS AND COUNTERTOPS U.N.O.
E ALL RESTROOM ACCESSORIES TO BE INSTALLED PER THE MANUFACTURER'S RECOMMENDED STANDARD MOUNTING HEIGHT, BUT
SHALL NOT EXCEED THE MAXIMUM REACH DIMENSIONS NOTED ABOVE AND AS REQUIRED BY THE FLORIDA ACCESSIBILITY CODE, 2023.
OPERABLE
PART
AUTOMATIC
DOOR ACTUATOR
HOUSE PHONE
INTERCOM
STATIONS
TEMPERATURE
SENSOR
AL
IG
N
LIGHT SWITCH
STROBE/
SPEAKER
C J
C J
TYPICAL AT CORRIDOR / AISLE
TEMPERATURE
SENSOR
STROBE
LIGHT SWITCH-
FOR (3) GANG OR (4)
GANG BOXES, ALIGN
LEFT EDGE WITH BOXES
ABOVE
C
JC
J
CORNER
GUARD
CRASH RAIL
TYPICAL AT ROOM
GYPSUM BOARD
CONTROL JOINT
AT OPENING
OPENING
EXIT SIGN
CARD
READER
FIRE ALARM SIGNAL/
STROBE
FIRE EXTINGUISHER
SIGN
RECESSED FIRE
EXTINGUISHER
CABINET
WALL MOUNTED
FIRE EXTINGUISHER
ANNUNCIATOR
PANEL
EMERGENCY POWER
POWER OFF
PUSH BUTTON
STATION
MANUAL PULL
AL
IG
N
AL
IG
N
CORNER
GUARD
MOUNTING HEIGHTS ARE BASED ON FLORIDA ACCESSIBILITY CODE, 2023.
TELEPHONE
OUTLET
4"
M
AX
1' -4
3' -6
1'-0"
EQ EQ
6" M
IN
6' -8
4' -0
4' -0
5' -6
U N
O 2'
-1 0" U
N O
4' -0
6' -8
6' -0
" M
AX
T.
O
. C
AB
IN
ET
4' -2
6' -8
C O
L 5'
-0
M
AX
4' -0
1' -6
4' -0
FE
H
AN
D
LE
4'
-0
4"
5/8" GYPSUM
BOARD
LIGHT GAUGE
METAL STUD
FRAMING
4'H CORNER
GUARD
1/
2"
1 1/2"
TYPICAL
BASE
4'H A
BV
B
AS
E
CORNER
GUARD
NOTE: REFER TO
SPECIFICATION
FOR MATERIAL
AND ATTACHMENT
OF CORNER
GUARD.
FIN FLOOR
NOTE:
CONTRACTOR TO COORDINATE WITH ARCHITECT
LOCATING CORNER GUARDS AFTER WALL
FINISHES ARE INSTALLED
NOTE:
WHERE A TACTILE SIGN IS
PROVIDED AT A DOOR, THE SIGN
SHALL BE LOCATED ALONGSIDE
THE DOOR AT THE LATCH SIDE.
WHERE A TACTILE SIGN IS
PROVIDED AT PAIR DOORS WITH
ONE ACTIVE LEAF, THE SIGN
SHALL BE LOCATED ON THE
INACTIVE LEAF. WHERE A TACTILE
SIGN IS PROVIDED AT PAIR DOORS
WITH TWO ACTIVE LEAFS, THE
SIGN SHALL BE LOCATED TO THE
RIGHT OF THE RIGHT HAND DOOR.
WHERE THERE IS NO WALL SPACE
AT THE LATCH SIDE OF A SINGLE
DOOR OR THE RIGHT SIDE OF THE
DOUBLE DOORS, SIGNS SHALL BE
LOCATED ON THE NEAREST
ADJACENT PARTITION.
CENTERED ON
TACTILE CHARACTERS
1'-6" MINIMUM
EQ EQ
1'- 6"
M
IN
IM
UM
DOOR FRAME
SIGNAGE AS SCHEDULED REFER
TO DRAWING 10-A-601.
SIGNS CONTAINING
TACTILE CHARACTERS
SHALL BE LOCATED SO
THAT A CLEAR FLOOR
SPACE OF 18" x 18"
MINIMUM, CENTERED ON
THE TACTILE
CHARACTERS, IS
PROVIDED BEYOND THE
ARC OF ANY DOOR
SWING BETWEEN THE
CLOSED POSITION AND
45° OPEN POSITION.
PUSH
PLATE OR
LEVER
6" AT NON-ACCESSIBLE LOCATIONS
FLOOR SPACE
1' - 6" CLEAR T
O
BO
TT
OM
O
F
HI
GH
ES
T
RA
IS
ED
C
HA
RA
CT
ER
5'- 0"
M
AX
IM
UM
CENTER
9"
XXXXXX
XXXX
TO
B
OT
TO
M
OF
LO
W
ES
T
RA
IS
ED
C
HA
RA
CT
ER
4'- 0"
M
IN
IM
UM
XXX
TH
IS
D O
CU
M
EN
T, A
ND
T
HE
ID
EA
S
AN
D
DE
SI
G
NS
IN
CO
RP
O
RA
TE
D
HE
RE
IN
, A
S
AN
IN
ST
RU
M
EN
T
O F
PR
O
FE
SS
IO
NA
L
SE
RV
IC
E, IS
T
HE
P
RO
PE
RT
Y O
F
JA
CO
BS
A
ND
IS
N
O T
TO
B
E
US
ED
, I
N W
HO
LE
O R
IN
P
AR
T, F O
R
AN
Y O
TH
ER
P
RO
JE
CT
W
IT
HO
UT
T
HE
W
RI
TT
EN
A
UT
HO
RI
ZA
TI
O N
O F
JA
CO
BS
JA
CO
BS
8.
A
LL
R
IG
HT
S
RE
SE
RV
ED
1 2 3 4 5 6
B
C
D
A
PROJ
DATE
DWG
VERIFY SCALE
BAR IS ONE INCH
ON ORIGINAL DRAWING.
DS
G
N
DR
CH
K
AP
VD
0 1"
RE
US
E O
F
DO
CU
M
EN
TS
File Path:
NO
DA
TE
DS
G
N
BY
AP
RV
SHEET OF 19
PLOT DATE:
DY
AL
W
TP
O
PE
RA
TI
O
NS
B
UI
LD
IN
G R
EM
O
DE
L
FL
-5
, C H
R
IS
TM
AS
, F L
C
IT
Y
O F
C O
C O
A C
O C
O A, F
LO
R
ID
A
BI
D
D O
C U
M
EN
TS
OCT 2025
D3953000
Autodesk Docs://US FL_D3953000_City of Cocoa_Dyal WTP Remodel/DWTP-JEG-ZN-10 OPERATIONS BUILDING REMODEL-ARCH_R24.rvt
As indicated
9/24/2025 9:19:55 AM
D
YA
L W
TP
S
TA
N
D
AR
D A
N D
A D
A M
O U
N
TI
N G
H
EI
G H
TS
10-A-501
A
DO
LS
AK
A
LI
ND
O
T
DO
DG
E
A
DO
LS
AK
AR
CH
IT
EC
TU
RA
L
1/4" = 1'-0"
CONTROL JOINTS, FIXTURES AND DEVICES
1 1/2" = 1'-0"
CORNER GUARD
12" = 1'-0"
TACTILE SIGNS AT DOORS
1/2" = 1'-0"
TYPICAL SIGNAGE MOUNTING LOCATION AT DOOR
PARTITION TYPE NOTESPARTITION TYPE NOTES
13. SMOKE RESISTANT, FIRE RESISTANT, AND FIRE RESISTANT SMOKE BARRIER PARTITIONS SHALL
EXTEND AND SEAL TO INSIDE FACE OF EXTERIOR SHEATHING, INCLUDING EXTENSIONS
THROUGH SOFFITS.
14. EACH PARTITION SHOWN ON THE DRAWINGS TO HAVE A FIRE AND SMOKE RESISTANT RATING
SHALLBE IDENTIFIED AS SUCH WITH A LABEL ABOVE THE CEILING ON EACH SEGMENT OF THE
WALL AND 6' - 0" OC MAX EACH SIDE.
15. REFER TO TOILET ACCESSORIES SHEET AND CASEWORK SHEET FOR MOUNTING DETAIL
INFORMATION.
16. REFER TO THE METAL FABRICATIONS DETAILS FOR MF REFERENCES IN PARTITIONS SECTION.
17. REFER TO STRUCTURAL DRAWINGS FOR REINFORCING INFORMATION.
18. GRAPHIC DESIGNATION
19. DO NOT APPLY BULLNOSE BLOCK AT CORNER GUARD LOCATIONS.
20. MASONRY REINFORCEMENT: REFERENCE STRUCTURAL DRAWINGS.
21. HW (HEAD OF WALL) DETAILS DO NOT ALTER PARTITION TYPES NOTED ON PLANS.
22. ALL STC RATINGS ARE BASED ON 20 GA. STUDS @ 16" O.C., UNLESS NOTED OTHERWISE (U.N.O.).
23. ALL STC RATINGS ARE DERIVED FROM LABORATORY TESTS OR VALUES EXTRAPOLATED USING
FUNDAMENTAL ACOUSTIC PRINCIPLES.
24. PROVIDE SOFT BODY/HARD BODY WALL ASSEMBLIES FOR INTERIOR EXIT STARWAYS AND
ELEVATOR HOISTWAYS AS INDICATED IN SPECIFICATIONS.
PRIORITY
2 HR SMOKE BARRIER
2 HR FIRE BARRIER
2 HR FIRE BARRIER/SHAFT WALL
1 HR SMOKE BARRIER
1 HR FIRE BARRIER
1 HR FIRE BARRIER/SHAFT WALL
SMOKE PARTITION (NON RATED)
1 HIGHEST
5 LOWEST
1. PARTITIONS ARE DISTINGUISHED ON FLOOR PLANS BY SYMBOL DESIGNATION, GRAPHIC DESIGNATION OR A
COMBINATION OF BOTH DESIGNATIONS.
2. THERE ARE TWO TYPES OF SYMBOL DESIGNATIONS, ONE FOR PARTITONS NOT REQUIRING SOUND ATTENUATION AND ANOTHER FOR PARTITIONS WHICH REQUIRE SOUND ATTENUATION. REFER TO PARTITION MATRICES FOR SOUND ATTENUATION BLANKET (SAB) MINIMUM THICKNESS FOR STC INDICATED.
3. THERE ARE TWO SYMBOL DESIGNATION SYSTEMS USED. THE FIRST SYSTEM CONSISTS OF TWO AND THREE CHARACTERS, THE FIRST CHARACTER IS A LETTER INDICATING THE PARTITION TYPE. THE SECOND CHARACTER IS NUMERIC INDICATING THE STUD OR CMU WIDTH. REFER TO LEGEND BELOW. THIS SYSTEM IS
USED TO DEFINE WALL TYPES: A, B, C, D, E, F, H, J, K, M, R
THE # CHARACTER BELOW THE LINE INDICATES THE HEIGHT OF THE SPECIFIC WALL COMPONENT. THE HEIGHT OF A SPECIFIC WALL COMPONENT. REFER TO THE LEGEND BELOW. THIS SYSTEM IS USED TO DEFINE WALL
TYPES: RA THRU RR
4. IF NO SYMBOL DESIGNATION IS PROVIDED, FOR A PARTITION ON THE FLOOR PLANS, THE WALL TYPE SHALL BE
AN A3 WITH SOUND BATTS.
5. THE GRAPHIC DESIGNATION IS INCORPORATED FOR PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE
RESISTANT, OR BOTH FIRE AND SMOKE RESISTANT. REFER TO NOTE 18.
6. "LINE OF STRUCTURE" INDICATED FOR EACH PARTITION IS DIAGRAMMATIC ONLY AND DOES NOT INDICATE
EXACT CONSTRUCTION CONDITIONS OR GEOMETRY.
7. ALL DIMENSIONS ARE FROM FACE OF GYPSUM BOARD TO FACE OF GYPSUM BOARD. REFER TO PARTITION
MATRICES FOR PARTITION WIDTH DIMENSIONS UNLESS INDICATED TO BE SHOWN ON PLAN.
8. SEALANT:
1. FIRE RESISTANCE RATED PARTITIONS SHALL USE RATED FIRE/SMOKE FIRE RESISTANT FILL MATERIAL IN CONJUNCTION WITH AN APPROPRIATE RATED FIRE/SMOKE FIRE STOPPING SYSTEM.
2. NON-RATED PARTITIONS AND NON-RATED SMOKE RESISTANT PARTITIONS SHALL USE ACOUSTICAL
SEALANT.
9. INSULATION: - HEAD CONDITIONS AT FLOOR/ROOF DECK
1. FIRE RESISTANCE RATED PARTITIONS SHALL USE MINERAL WOOL INSULATION.
2. NON-RATED PARTITIONS REQUIRING SOUND ATTENUATION SHALL USE SOUND ATTENUATION
BLANKETS (SAB).
3. PROVIDE FULL THICKNESS INSULATION INSIDE ALL STUD BOX BEAMS AND HEADERS WHICH
OCCUR IN WALLS WITH SOUND ATTENUATION.
10. REFER TO SPECIFICATIONS FOR MINIMUM STUD THICKNESS, MAXIMUM SPACING AND ALLOWABLE LIMITING
HEIGHTS DEFLECTION CRITERIA FOR GYPSUM BOARD ASSEMBLIES.
11. FOR PARTITIONS INDICATED TO RECEIVE SOUND ATTENUATION BLANKETS (SAB), EXTEND SAB TO FULL
HEIGHT OF PARTITION UNLESS OTHERWISE INDICATED.
12. FIRE RESISTANT AND FIRE RESISTANT SMOKE BARRIER RATINGS ARE TO SURROUND ALL OPENINGS
IN RATED PARTITIONS.
NUMERIC
CHARACTER
STUD
WIDTH
CMU
WIDTH
1 5/8" 3 5/8"
NUMERIC
CHARACTER
CMU/BRICK
HEIGHT
9' - 4" 10' - 8" 12' - 8" 18' - 8" 14' - 0"
SYMBOL DESIGNATIONS
(NO SOUND ATTENUATION)
SYMBOL DESIGNATION
(WITH SOUND ATTENUATION)
X# X#XXXX
# XXXX
SEALANT
MTL RUNNER
LINE OF
STRUCTURE
LINE OF CEILING
LINE OF
STRUCTURE
WITH SOUND
STC:
NO SOUND
3 5/8" 4 7/8" NON-
RATED N/A 44
(W3 1/2" SAB)
37A3 A3
TYPE "A"TYPE "A"
PARTITION WIDTH
REFER TO SCHEDULE
BELOW FOR
FLOOR PLAN
DESIGNATION
NO SOUND
ATTENUATION
FLOOR PLAN
DESIGNATION
WITH SOUND
ATTENUATION
STUD
SIZE
PART
WIDTH
FIRE
RATING
UL
LISTING
LABORATORY
TEST REPORT
& REMARKS
USG - 150919
REFER TO PARTITION
HEAD DETAILS
SEALANT
STUD BOTTOM TRACK
5/8" GYP BD EACH SIDE
1 5/8" 3" NON-
RATED N/AN/A N/A
SEALANT
MTL RUNNER
5/8" GYP BD
LINE OF
STRUCTURE
LINE OF
STRUCTURE
BRACE EACH STUD
AT 4'-0" OC
VERTICALLY
LINE OF STRUCTURE OR
OTHER CONSTRUCTION
PROVIDING BACK-UP FOR
STUD BRACING
K1
LINE OF CEILING
3"
PARTITION WIDTH 3" MIN
REFER TO SCHEDULE
BELOW FOR
TYPE "K"TYPE "K"
FLOOR PLAN
DESIGNATION
NO SOUND
ATTENUATION
FLOOR PLAN
DESIGNATION
WITH SOUND
ATTENUATION
STUD
SIZE
PART
WIDTH
FIRE
RATING
UL
LISTING
LABORATORY
TEST REPORT
& REMARKS
SOUND
TRANS.
CLASS
1. REFER TO SPECIFICATIONS FOR HEAD OF WALL SLOTTED TRACK
OPTIONS FOR METAL STUD WALLS. CONT 2" WIDE X 22 GA METAL
STRAP CAN BE DELETED IF OPTIONAL SLOTTED TRACKS ARE
SELECTED.
HEAD OF WALL GENERAL NOTESHEAD OF WALL GENERAL NOTES
NON-RATED OR SMOKE RESISTANT
FLUTED STEEL DECK/CONCRETE FLOOR OR ROOF
PERPENDICULAR OR DIAGONAL TO FLUTES
CONT 2" WIDE X 22 GA
MTL STRAP FOR TOP
ATTACHMENT OF GYP BD
CONT 22 GA MIN 3"
DEEP LEG DEFLECTION
TRACK ATTACH TO
DECK AT 12" OC MAX
DO NOT ATTACH GYP BD OR
STUDS TO DEFLECTION
TRACK IN THIS AREA
SEALANT
1"
3/ 4". 3/ 4"
3/ 4"
MINERAL WOOL
INSULATION
1"
7/
NON-RATED OR SMOKE RESISTANT
FLUTED STEEL DECK/CONCRETE FLOOR OR ROOF
PARALLEL TO FLUTES
CONT 2" WIDE X 22 GA
MTL STRAP FOR TOP
ATTACHMENT OF GYP BD
CONT 22 GA MIN 3"
DEEP LEG DEFLECTION
TRACK ATTACH TO
DECK AT 12" OC MAX
DO NOT ATTACH GYP BD
OR STUDS TO DEFLECTION
TRACK IN THIS AREA
SEAL ONE SIDE OF
PARTITION AGAINST
PASSAGE OF SMOKE
WHEN PARTITION IS ALIGNED
AT DECK FLUTE RECESS -
PROVIDE A 6" X 10" X 22 GA MTL
PLATE AT DECK FLUTE RECESS
THAT IS CONTIGUOUS WITH
PARTITION - ATTACH MTL PLATE
TO DECK WITH POWDER
DRIVEN FASTENERS AT SAME
SPACING REQUIRED FOR
PARTITION TOP TRACK
3/ 4" 3/ 4"
CONT 20 GA GALV
MTL STRAP ACROSS
MTL DECK FLUTES
3/ 4"
1. REFER TO SPECIFICATIONS FOR HEAD OF WALL SLOTTED TRACK
OPTIONS FOR METAL STUD WALLS. CONT 2" WIDE X 22 GA METAL
STRAP CAN BE DELETED IF OPTIONAL SLOTTED TRACKS ARE
SELECTED.
HEAD OF WALL GENERAL NOTESHEAD OF WALL GENERAL NOTES
TH
IS
D O
CU
M
EN
T, A
ND
T
HE
ID
EA
S
AN
D
DE
SI
G
NS
IN
CO
RP
O
RA
TE
D
HE
RE
IN
, A
S
AN
IN
ST
RU
M
EN
T
O F
PR
O
FE
SS
IO
NA
L
SE
RV
IC
E, IS
T
HE
P
RO
PE
RT
Y O
F
JA
CO
BS
A
ND
IS
N
O T
TO
B
E
US
ED
, I
N W
HO
LE
O R
IN
P
AR
T, F O
R
AN
Y O
TH
ER
P
RO
JE
CT
W
IT
HO
UT
T
HE
W
RI
TT
EN
A
UT
HO
RI
ZA
TI
O N
O F
JA
CO
BS
JA
CO
BS
8.
A
LL
R
IG
HT
S
RE
SE
RV
ED
1 2 3 4 5 6
B
C
D
A
PROJ
DATE
DWG
VERIFY SCALE
BAR IS ONE INCH
ON ORIGINAL DRAWING.
DS
G
N
DR
CH
K
AP
VD
0 1"
RE
US
E O
F
DO
CU
M
EN
TS
File Path:
NO
DA
TE
DS
G
N
BY
AP
RV
SHEET OF 19
PLOT DATE:
DY
AL
W
TP
O
PE
RA
TI
O
NS
B
UI
LD
IN
G R
EM
O
DE
L
FL
-5
, C H
R
IS
TM
AS
, F L
C
IT
Y
O F
C O
C O
A C
O C
O A, F
LO
R
ID
A
BI
D
D O
C U
M
EN
TS
OCT 2025
D3953000
Autodesk Docs://US FL_D3953000_City of Cocoa_Dyal WTP Remodel/DWTP-JEG-ZN-10 OPERATIONS BUILDING REMODEL-ARCH_R24.rvt
As indicated
9/24/2025 9:19:56 AM
D
YA
L W
TP
P
AR
TI
TI
O
N T
YP
ES
10-A-502
A
DO
LS
AK
A
LI
ND
O
T
DO
DG
E
A
DO
LS
AK
AR
CH
IT
EC
TU
RA
L
GENERAL NOTES WALL TYPES
1 INFORMATION CONTAINED ON THIS DRAWING ONLY APPLIES TO INTERIOR PARTITIONS. FOR
EXTERIOR WALL ASSEMBLIES AND CONDITIONS, SEE EXTERIOR WALL SECTIONS.
2 SEE STRUCTURAL DRAWINGS FOR REINFORCING REQUIREMENTS FOR ALL MASONRY AND
CONCRETE PARTITIONS.
3 ALL STC VALUES PROVIDED ON THIS SHEET ASSUME PARTITION CONTAINS BATT INSULATION. SEE UL
ASSEMBLY FOR INSULATION REQUIREMENTS.
4 REFER TO FINISH SCHEDULE FOR SCOPE OF FINISHES ATTACHED TO FACE OF PARTITIONS,
INCLUDING CERAMIC TILE, STONE VENEER, WOOD PANELS, VINYL FABRIC, PAINT AND OTHER
FINISHES.
5 INSTALL GYPSUM BOARD W/ STAGGERED JOINTS AND TAPE AND FINISH ALL JOINTS W/ COMPOUND
EACH LAYER
6 USE MOISTURE RESISTANT GYPSUM BOARD FOR ALL INTERIOR WALL AND CEILING CONDITIONS AT
ALL TOILETS, LOCKER ROOMS AND KITCHENS UNLESS NOTED OTHERWISE.
7 UNLESS NOTED OTHERWISE, PROVIDE GYPSUM BOARD CONTROL JOINTS IN THE FOLLOWING:
30'-0" MAXIMUM INTERIOR PARTITIONS
50'-0" MAXIMUM INTERIOR CEILING WITH PERIMETER RELIEF
30'-0" MAXIMUM INTERIOR CEILING WITHOUT PERIMETER RELIEF
30'-0" MAXIMUM EXTERIOR GYPSUM CEILINGS
8 COORDINATE LOCATION OF GYPSUM CONTROL JOINTS WITH LOCATION OF DOORS, SOFFITS, ETC.
9 SEALING PENETRATION AT FIRE RATED WALLS SHALL BE IN ACCORDANCE WITH SPECIFICATION
SECTION 07250
10 TO MAINTAIN FIRE RATING AT WALL PLAN INTERSECTIONS, SEE DETAILS 17-20 ON A-0005 11 FIRE AND SMOKE RATED WALLS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS
OR STENCILING IN A MATTER ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION. SUCH
IDENTIFICATION SHALL BE ABOVE CEILINGS AND CONCEALED SPACES AT 12'-0" O.C. MAX. ON BOTH SIDES OF PARTITION. WORDING SHALL READ "2 HR FIRE RATED BARRIER. PROTECT ALL OPENINGS".
EDITOR'S NOTE:
PROVIDE 33' WIDE KNEE SPACE.
X
1/
2" M
AX
X
17" MIN
19”
M
IN
C
LE
AR
2'
3"
TO
T
O P
O F
SI
N
K R
IM
2'
COUNTERTOP AND
APRON
SEALANT AROUND
EDGE OF SINK
FINISH WALL
ACCESSIBLE FAUCET
BACKSPLASH
ACCESSIBLE SINK
REMOVABLE PANEL
ON "Z-CLIPS"
LINE OF BASE
CABINET BEYOND
FINISHED FLOOR
11" MIN
13”
8" MIN
10"
M
IN9"
MAINTAIN 6:1 SLOPE
CLEARANCE FOR KNEES
REACH DEPTH TO FAUCET
CANNOT EXCEED KNEE AND
TOE CLEARANCE FOR FRONT
APPROACH
THE KNEE AND TOE CLEARANCE
MUST BE AT LEAST AS DEEP AS
DIMENSION REQUIRED TO REACH
FAUCET FOR A FRONT APPROACH
CLEARANCE
6" MAX
TOE
BASE CABINET
OR EQUIPMENT
UPPER CABINET
OR EQUIPMENT
CEILING LINE OF STRUCTURE
TYPE B MOUNTING
TYPE B MOUNTING
20 GA METAL STUDS
TYPE B MOUNTING
NOTE:
DO NOT CUT VERTICAL
STUD FLANGES
.1'-10"
.1'-0"
UNDER CABINET
LIGHTING, SEE
ELECTRICAL
TYPICAL CABINET DIMENSIONS
NOTE: ALL CABINET DIMENSIONS GIVEN ARE NOMINAL.
2' - 0"
4"
2' - 0 3/4" 2' - 0"
M
IN
2'
3"
MOUNTING
SUPPORT
TYPE B TYP
BASE CABINET COUNTERTOP APRON / KNEE SPACE
PLAM - PLASTIC LAMINATE UNO
CP - CAST PLASTIC
(SOLID SURFACING MATERIAL)
ER - EPOXY RESIN
SS - STAINLESS STEEL
ST - STONE
SS
1' - 3"
MOUNTING
SUPPORT
TYPE B TYP
UPPER CABINET
1' - 0"
3'
4"
BASE
CABINET
WIRE ACCESS
SLOT
LABORATORY
CABINET TYPES
UPPER
CABINETS
DOOR FRONT OPEN
UBUA
BASE
CABINETS
DOOR(S) WITH
DRAWERS
DOOR(S) WITH
APRON
BA BD
FF
84"
SCHEDULED
CEILING HEIGHT
84"
60" 54" 48" 36" 34"
30"
FF
MIN 20 GA MTL STUDS
FACING OPPOSITE
DIRECTIONS TO ALLOW
MOUNTING PLATE
ATTACHMENT (16 GA AT
SHOWER SEATS AND ADULT
CHANGING STATIONS)
14 GA STL RUNNER TRACK-
CLIP FLANGES AND FOLD
WEB TO FORM
ATTACHMENT FLANGE
R
EF
ER
T
YP
IC
AL
M
O U
N
TI
N G
H
EI
G H
TS
8" MIN DEEPER
IF REQUIRED
TYPE CTYPE BTYPE A
R
EF
ER
T
YP
IC
AL
M
O U
N
TI
N G
H
EI
G H
TS
CONT 20 GA
4" WIDE MTL
BACK-UP
PLATE
R
EF
ER
T
YP
IC
AL
M
O U
N
TI
N G
H
EI
G H
TS
CONT 18 GA 6"
TALL - 8" ONLY
REQUIRED BY
FHA FOR
GRAB BARS
TH
IS
D O
CU
M
EN
T, A
ND
T
HE
ID
EA
S
AN
D
DE
SI
G
NS
IN
CO
RP
O
RA
TE
D
HE
RE
IN
, A
S
AN
IN
ST
RU
M
EN
T
O F
PR
O
FE
SS
IO
NA
L
SE
RV
IC
E, IS
T
HE
P
RO
PE
RT
Y O
F
JA
CO
BS
A
ND
IS
N
O T
TO
B
E
US
ED
, I
N W
HO
LE
O R
IN
P
AR
T, F O
R
AN
Y O
TH
ER
P
RO
JE
CT
W
IT
HO
UT
T
HE
W
RI
TT
EN
A
UT
HO
RI
ZA
TI
O N
O F
JA
CO
BS
JA
CO
BS
8.
A
LL
R
IG
HT
S
RE
SE
RV
ED
1 2 3 4 5 6
B
C
D
A
PROJ
DATE
DWG
VERIFY SCALE
BAR IS ONE INCH
ON ORIGINAL DRAWING.
DS
G
N
DR
CH
K
AP
VD
0 1"
RE
US
E O
F
DO
CU
M
EN
TS
File Path:
NO
DA
TE
DS
G
N
BY
AP
RV
SHEET OF 19
PLOT DATE:
DY
AL
W
TP
O
PE
RA
TI
O
NS
B
UI
LD
IN
G R
EM
O
DE
L
FL
-5
, C H
R
IS
TM
AS
, F L
C
IT
Y
O F
C O
C O
A C
O C
O A, F
LO
R
ID
A
BI
D
D O
C U
M
EN
TS
OCT 2025
D3953000
Autodesk Docs://US FL_D3953000_City of Cocoa_Dyal WTP Remodel/DWTP-JEG-ZN-10 OPERATIONS BUILDING REMODEL-ARCH_R24.rvt
As indicated
9/24/2025 9:19:56 AM
D
YA
L W
TP
C
AB
IN
ET
D
ET
AI
LS
10-A-503
A
DO
LS
AK
A
LI
ND
O
T
DO
DG
E
A
DO
LS
AK
AR
CH
IT
EC
TU
RA
L
1" = 1'-0"
ACCESSIBLE FRONT APPROACH SINK SECTION
1/4" = 1'-0"
TYP STUD WALL SUPPORTING CABINETRY
1/4" = 1'-0"
TYPICAL CABINET TYPES AND DIMENSIONS
1/4" = 1'-0"
ACCESSORY MOUNTING DETAILS
D
SINGLE
D/D
DOUBLE
DOOR FRAME TYPES
SCHEDULE
SEE
SE
E
SC
H
ED
U
LE
2" 2"
2"
SEE SCHEDULE
2" 2"
2"
SE
E
SC
H
ED
U
LE
G
HALF GLASS
G/G
DOUBLE HALF GLASS
DOOR TYPES
6"
SE
E
SC
H
ED
U
LE
6" 6"
SCHEDULE
SEE
6"
SE
E
SC
H
ED
U
LE
6" 6"6" 6"
SCHEDULE
SEE
DASHED FRAMING
FOR PAIR (DOUBLE)
OF DOORS
GYP BOARD
HOLLOW METAL
FRAME
SEALANT AT
PERIMETER OF
FRAME TO MATCH
FRAME PAINT
COLOR
DOOR AS
SCHEDULED
GYP BOARD
HOLLOW METAL
FRAME
SEALANT AT
PERIMETER OF FRAME
TO MATCH FRAME
PAINT COLOR
DOOR AS SCHEDULED
LINTEL BEAM
HOLLOW METAL
FRAME
M O
EXISTING 12" CMU
SEALANT
GYP BD
2 1/2" 22 GA METAL Z
FURRING 16" OC
2"
EXISTING 12" CMU
WITH GROUT FILL
M O
SEALANT
HOLLOW METAL
FRAME
GYP BD
2 1/2" 22 GA METAL Z
FURRING 16" OC
MANUFACTURER'S
STANDARD JAMB
ANCHORS
F-1 B-1 P-1 P-2 O-1 M-1 M-2
MARK
ACOUSTICAL TILE CEILING
SOLID SURFACE COUNTER TOP AND BACKSPLASH
WOOD DOORS
PAINT
RUBBER BASE
PAINT
MATERIAL
FLUID APPLIED FLOORING
ARMSTRONG PRELUDE FISSURED
WILSONART SOLID SURFACING
LAMBTON DOORS
SHERWIN WILLIAMS
TARKETT - DURACOVE RUBBER
SHERWIN WILLIAMS
MANUFACTURER
FLOROCK - FLOROQUARTZ BC
WHITE
ANGEL FALLS (9223SS)
RED OAK, CLEAR FINISH (PLS-100)
#7013 IVORY LACE
RUBBER BASE
COLOR
FLUID APPLIED FLOORING
M-3 CABINET - PLASTIC LAMINATE WILSONART CRYSTAL WITH MATTE FINISH (D388-60)
COLOR LIST
THRESHOLD
AS SCHEDULED,
SET IN SEALANT
FLOOR FINISH AS
SCHEDULED
FLOOR LINE
DOOR AS
SCHEDULED
SWEEPSTRIP AS
SCHEDULED
D O
O R
H
EI
G H
T
TH
IS
D O
CU
M
EN
T, A
ND
T
HE
ID
EA
S
AN
D
DE
SI
G
NS
IN
CO
RP
O
RA
TE
D
HE
RE
IN
, A
S
AN
IN
ST
RU
M
EN
T
O F
PR
O
FE
SS
IO
NA
L
SE
RV
IC
E, IS
T
HE
P
RO
PE
RT
Y O
F
JA
CO
BS
A
ND
IS
N
O T
TO
B
E
US
ED
, I
N W
HO
LE
O R
IN
P
AR
T, F O
R
AN
Y O
TH
ER
P
RO
JE
CT
W
IT
HO
UT
T
HE
W
RI
TT
EN
A
UT
HO
RI
ZA
TI
O N
O F
JA
CO
BS
JA
CO
BS
8.
A
LL
R
IG
HT
S
RE
SE
RV
ED
1 2 3 4 5 6
B
C
D
A
PROJ
DATE
DWG
VERIFY SCALE
BAR IS ONE INCH
ON ORIGINAL DRAWING.
DS
G
N
DR
CH
K
AP
VD
0 1"
RE
US
E O
F
DO
CU
M
EN
TS
File Path:
NO
DA
TE
DS
G
N
BY
AP
RV
SHEET OF 19
PLOT DATE:
DY
AL
W
TP
O
PE
RA
TI
O
NS
B
UI
LD
IN
G R
EM
O
DE
L
FL
-5
, C H
R
IS
TM
AS
, F L
C
IT
Y
O F
C O
C O
A C
O C
O A, F
LO
R
ID
A
BI
D
D O
C U
M
EN
TS
OCT 2025
D3953000
Autodesk Docs://US FL_D3953000_City of Cocoa_Dyal WTP Remodel/DWTP-JEG-ZN-10 OPERATIONS BUILDING REMODEL-ARCH_R24.rvt
As indicated
9/24/2025 9:19:57 AM
D
YA
L W
TP
D
O O
R A
N D
F
IN
IS
H
SC
H
ED
U
LE
10-A-504
A
DO
LS
AK
S
SL
AY
TO
N T
DO
DG
E A
DO
LS
AK
AR
CH
IT
EC
TU
RA
L
DOOR SCHEDULE
MARK
DOOR FRAME DETAILS
HARDWARE
DOOR
FIRE
RATING REMARKSWIDTH HGT TYPE MATL
GLASS
TYPE FINISH TYPE MATL FINISH HEAD JAMB SILL
10101A 3'-0" 7'-0" G WD TG FCTY D HM PS-106 0811-007 0811-008 0841-010 HW-1 NR 1,2 TEXT: BREAKROOM 10103A 6'-0" 7'-0" GG WD TG FCTY DD HM PS-106 0811-007 0811-008 0841-010 HW-2 NR 1,2 TEXT: INSTRUMENT REPAIR / OFFICE 10103B 3'-0" 7'-0" G WD TG FCTY D HM PS-106 0811-007 0811-008 0841-010 HW-4 NR 1,2 TEXT: SAMPLE ROOM 10104A 3'-0" 7'-0" G WD TG FCTY D HM PS-106 0811-007 0811-008 0841-010 HW-1 NR 1,2 TEXT: BREAKROOM 10105A 3'-0" 7'-0" G WD TG FCTY D HM PS-106 0811-007 0811-008 0841-010 HW-4 NR 1,2 TEXT: ELECTRICAL WORKSHOP 10108A 2'-4" 7'-0" F EXISTING NA PS-106 D EXISTING PS-106 EXISTING EXISTING EXISTING --- NR 3 TEXT: UNISEX TOILET 10109A 2'-4" 7'-0" F EXISTING NA PS-106 D EXISTING PS-106 EXISTING EXISTING EXISTING --- NR 3 TEXT: MEN'S TOILET / LOCKERS 10111A 3'-0" 7'-0" G WD TG FCTY D HM PS-106 0811-007 0811-008 0841-010 HW-3 NR 1,2 TEXT: JANITOR 10112A 3'-0" 7'-0" G WD TG FCTY D HM PS-106 0811-001 0811-002 0841-010 HW-3 NR 1,2 TEXT: OFFICE 10113A 3'-0" 7'-0" G WD TG FCTY D HM PS-106 0811-001 0811-002 0841-010 HW-3 NR 1,2 TEXT: OFFICE
ROOM FINISH SCHEDULE
NO NAME
SUB
FL
FLOORING BASE WALLS AND PARTITIONS CEILING
REMARKSMATL FINISH COL HGT MATL COL
NORTH EAST SOUTH WEST
MATL FINISHMATL FINISH COL MATL FINISH COL MATL FINISH COL MATL FINISH COL
10103 INSTRUMENT REPAIR / OFFICE CONC FAF FCTY F-1 4" RUB B-1 CMU PS-114 P-2 CMU PS-114 P-2 CMU PS-114 P-2 CMU PS-114 P-2 ACT M-1 10104 BREAK ROOM CONC FAF FCTY F-1 4" RUB B-1 GWB PS-109 P-2 GWB PS-109 P-2 GWB PS-109 P-2 GWB PS-109 P-2 ACT M-1 10105 ELECTRICAL WORKSHOP CONC FAF FCTY F-1 4" RUB B-1 CMU PS-114 P-2 CMU PS-114 P-2 CMU PS-114 P-2 CMU PS-114 P-2 ACT M-1 10107 CORRIDOR CONC FAF FCTY F-1 4" RUB B-1 CMU PS-114 P-2 CMU PS-114 P-2 CMU PS-114 P-2 CMU PS-114 P-2 ACT M-1 10112 OFFICE CONC FAF FCTY F-1 4" RUB B-1 GWB PS-109 P-2 GWB PS-109 P-2 GWB PS-109 P-2 GWB PS-109 P-2 ACT M-1 10113 OFFICE CONC FAF FCTY F-1 4" RUB B-1 GWB PS-109 P-2 GWB PS-109 P-2 GWB PS-109 P-2 GWB PS-109 P-2 ACT M-1
REMARKS:
1. NUMBERS IN HARDWARE COLUMN REFER TO HARDWARE SETS IN SPECIFICATION SECTION 08 71 00, DOOR HARDWARE.
2. NUMBERS IN "FINISH" COLUMN REFER TO PAINT SYSTEMS IN SPECIFICATION SECTION 09 90 00, PAINTING AND COATING.
3. EXISTING DOOR AND FRAME TO BE PAINTED.
REMARKS:
1. NUMBERS IN "FINISH" COLUMNS REFER TO PAINT SYSTEMS IN SPECIFICATION SECTION 09 90 00, PAINTING AND COATING.
3" = 1'-0"
INTERIOR DOOR HEAD DETAIL -
HOLLOW METAL
3" = 1'-0"
INTERIOR DOOR JAMB DETAIL -
HOLLOW METAL
3" = 1'-0"
INTERIOR DOOR HEAD…