Buildings_&_Grounds_Warehouse_#65_Exterior_Renovations_for_Ocean_County_-_Drawings.pdf

PDF 12 MB Posted

Attached to
BUILDINGS & GROUNDS WAREHOUSE #65 EXTERIOR RENOVATIONS FOR OCEAN COUNTY
Solicitation number
OCBG72826
Issued by
Ocean County, New Jersey

About this file

Building Exterior Renovation Project Summary

This file consists of comprehensive architectural drawings and specifications for Buildings & Grounds Warehouse #65 Exterior Renovations for Ocean County, New Jersey, prepared by Yezzi Associates. The project involves exterior renovation work at 162 Chestnut Street in Toms River, New Jersey, for a single-story warehouse structure with approximately 17,500 square feet of building area and a roof height of 55 feet. The base scope of work includes providing and installing a new metal roof system over the existing roof, new metal gutters and downspouts with PVC boot connections to the existing storm drain system, splash blocks where required, new metal soffits, and removal and replacement of existing metal siding from finish floor to 3 feet above finished floor. The project also requires raising or extending existing rooftop mechanical equipment and vents to accommodate the new roofing system and comply with applicable codes. The contractor must maintain all existing electrical, HVAC, and plumbing systems, and address all roof penetrations by resealing and extending them as required by code.

Three bid alternates are included in addition to the base bid: Alternate #1 covers removal and replacement of 14 existing exterior doors with new fiberglass reinforced panel (FRP) doors and aluminum frames; Alternate #2 addresses removal and replacement of 19 existing exterior windows with new units featuring 1-inch insulated glass; and Alternate #3 provides for power washing and painting the existing exterior building, including coiling doors and frames with primer and two finish coats. The project shall comply with the 2021 Uniform Construction Code of New Jersey, the 2021 International Building Code, and ASHRAE 90.1-2019 standards. All roofing materials, gutters, downspouts, and metal panels are specified as products manufactured by IMETCO or architect-approved equals, with metal roofing featuring a 0.5/12 slope across eight ridge spans totaling approximately 305 linear feet. The contractor must submit complete engineered shop drawings signed and sealed by a New Jersey-licensed professional engineer prior to construction, coordinate all work to prevent duplication, protect existing utilities and landscaping, maintain temporary weatherproof closures during work, remove construction debris daily, and obtain field verification of all existing conditions and utilities prior to bid submission and construction start.

View the file

Other files

File Type Posted
Buldings_&_Grounds_Warehouse_#65_Exterior_Renovations_for_Ocean_County_-_Specifications.pdf PDF
SMART_Local_137_CBA_2026-29.pdf PDF
Boilermakers_Local_28_CBA_2025-27.pdf PDF
Sprinklerfitters_Local_669_CBA_-_2025_-_30.pdf PDF
SMART_Local_27_CBA_-_2024-27.pdf PDF
Insulators_Local_89_CBA-2021-26.pdf PDF
Painters_-_Glazers_DC711-CBA-2021-2026.pdf PDF
Glaziers_Local_1009_CBA-2023-26.pdf PDF
Laborers_Local_77_CBA_-_2022-27.pdf PDF
Laborers_Local_472-172_CBA-2024_27.pdf PDF
Model_Project_Labor_Agreement_(PLA)_Monmouth-Ocean.docx DOCX document
Local_9_Plumbers_Pipefitterr_CBA_-_2025-29.pdf PDF
Local_7_Tile,_Marble,_Terrazzo_SNJ_CBA-2022-27.pdf PDF
NJ_Carpenter_CBA_2022-27.pdf PDF
Elevator_Local_5_CBA-2022-27.pdf PDF
Local_469_Teamsters_CBA-2025-28.pdf PDF
Roofers_Local_30_CBA_-_2022-25.pdf PDF
OE_Local_825_CBA-_2023-26.pdf PDF
Plumbers_Pipefitters_Local_322_CBA_-_2025-28.pdf PDF
Iron_Workers_Local_399_CBA_-_2023-28.pdf PDF
Drywall_DC_711_CBA_2022-2025.pdf PDF
Electricians_Local_400_CBA-_2023-27.pdf PDF
AIA_General_Conditions_for_Contract_and_Modifications_to_General_Conditions.pdf PDF
Bricklayers_4-5_2022-2027.pdf PDF
Yezzi_Associates_Architect_Submission_Forms_(Reference_Use_Only).pdf PDF
Cement_Masons_Local_592_CBA-_2025-28.pdf PDF
Sample_Surety_Forms.pdf PDF
Instructions_for_Completing_Forms_in_DocuSign.pdf PDF
Dockbuilders_Local_474_CBA_-_2022-27.pdf PDF
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BUILDINGS & GROUNDS WAREHOUSE #65 EXTERIOR RENOVATIONS FOR OCEAN COUNTY

PER TABLE (504.3 & 504.4) SECTION (506.2)

ALLOWANCE HEIGHT

ALLOWANCE AREA

TYPE

162 CHESTNUT STREET

OCCUPANT LOAD

USE GROUP

BUILDING ELEMENT FIRE RESISTANCE RATINGS

CONSTRUCTION CLASSIFICATION

OCCUPANCY CLASSIFICATION

PLAN REVIEW DATA

T.O.W.TOP OF WALLPTD.PAINTEDCONDITIONINGCONCRETE CONC.

DOOR CALLOUT

ROOM IDENTIFICATION

WINDOW NUMBER

WINDOW NUMBER

EXTERIOR WINDOW CALLOUT

INTERIOR WINDOW CALLOUT

MFR./MANUF.

LVR./LOUV.

NOTE: THIS LIST REPRESENTS ABBREVIATIONS THAT MAY OR MAY NOT APPEAR IN THESE DOCUMENTS. CONTACT YEZZI ASSOCIATES FOR ANY CLARIFICATIONS REGARDING THE ABBREVIATIONS

SYMBOL KEY

DEAD LOAD

DIFFUSER

DIMENSION

DIAMETER

CONTRACTOR

CLEAN OUT

DEMOLISH, DEMOLITION

CONCRETE MASONRY UNIT

CONTINUOUS/CONTINUE

CONTROL JOINT

FINISH FLOOR

FEET, FOOT

EXTERIOR

EQUIPMENT

FLOOR CLEAN OUT

X-X

XX

XX

XX

XX

X X-X

X-X

X X-X

FINISH

DOWN

DITTO

EXISTING

EQUAL

EXTERIOR ELEVATION CALLOUT

INTERIOR ELEVATION CALLOUT

EXT. ELEV. NUMBER

SHEET NUMBER

SHEET NUMBER

SHEET NUMBER

INT. ELEV. NUMBER

I

XX

E

XX

ROOM NUMBER

EXTERIOR

INTERIOR

HOUR

HOLLOW METAL FRAME

HOSE BIB

HOT WATER

INTERIOR

INSULATION

HEIGHT

HOLLOW CORE

HOLLOW METAL

HIGH POINT

LOUVER

LAMINATE(D)

LIVE LOAD

LAVATORY

MANUFACTURER

INVERT

JOINT

MAINTENANCE/MAINTAIN

LAMINATED VENEER LUMBER

FT.

DETAIL CALLOUT

SECTION CALLOUT

FIN.

F.F.

DETAIL NUMBER

SHEET NUMBER

SECT. NUMBER

DIA./

D.L.

DIM.

C.J.

C.O.

DEMO.

DIFF.

CONT.

C.M.U.

CONTR.

EQ.

EXT.

"do"

DN.

EXIST./EXIST'G

F.C.O.

EQUIP.

Ø

ROOM

NAME

DOOR NUMBER

MAINT.

L.V.L.

LAV.

LAM.

L.L.

JT.

INV.

INT.

INSUL.

H.B.

H.W.

HR.

H.M.F

H.V.A.C.

H.M.

H.P.

H.C.

HT.

UNIFORM BUILDING CODE

VINYL COMPOSITION TILE

VINYL WALL COVERING

UNDERWRITERS LABORATORIES

WATERPROOF, WEATHERPROOF

WELDED WIRE FABRIC

WELDED WIRE MESH

WALL TYPE KEYX

N

NORTH ARROW

ELEVATION MARK

ROUGH OPENING

ROOF SCUPPER

E

X

POUNDS PER SQUARE FOOT

POUNDS PER LINEAL FOOT

POUNDS PER CUBIC FOOT

PARALLEL STRAND LUMBER

POUNDS PER SQUARE INCH

POLYVINYL CHLORIDE

PLASTIC LAMINATE

REINFORCE, REINFORCING

ROOF DRAIN

QUARRY TILE

PREFABRICATED

RISER

RADIUS

REQUIRED

REFERENCE

PLATE

PLUMBING

PLASTER

PARTITION

R.D.

COLUMN MARK

R.O.

R.S.

VERTICAL

VESTIBULE

TREAD

TYPICAL

UNFINISHED

WOOD

WITHOUT

WIRE GLASS

WITH

WATER CLOSET

VERIFY IN FIELDPREFAB.

REQ./REQ'D.

P.S.I.

R

REINF.

REF.

RAD.

Q.T.

PART'N.

PLBG.

P.C.F.

P.V.C.

P.S.F.

P.L.F.

PL.

P.S.L.

P.LAM.

PLAS.

V.W.C.

VERT.

VEST.

W.W.M.

W.W.F.

W/O

WD.

W.GL.

W/

W.P.

W.C.

V.I.F.

U.B.C.

V.C.T.

T

UNF.

U.L.

TYP.

HDW./HDW'R.

G.W.B./GYP. BD.

ALUMINUM

ALTERNATE

APPROVED

ACOUSTICAL CEILING TILE

ABOVE FINISH FLOOR

AIR CONDITIONING

STANDARD ABBREVIATIONS

COLD WATER

CERAMIC TILE

CENTERLINE

BLOCKING

BOARD

COLUMN

CERAMIC

COATS

CARPET

CEILING

BUILDING

AT

BLOCK

FIRE EXTINGUISHER

FLOOR

FLUORESCENT

FLOOR DRAIN

FLOOR SINK

FURRING

FURNISH

FOOTING

GLASS, GLAZING

GYPSUM WALLBOARD

GENERAL, GENERATOR

HARDWOOD

HARDWARE

GRADE

GAUGE

GALVANIZED

HEATING/VENTILATING/AIR

GENERAL CONTRACTOR(OR)

GROUND FAULT INTERRUPTER

A/C

ALT.

APPD./APPV'D

ALUM.

A.C.T.

A.F.F.

C.W.

CTS.

C

CER.

C.T.

CPT.

CLG.

BD.

COL.

BLKG.

BLDG.

BLK.

L

GALV.

G.F.I.

HWD.

G.C.

GL.

GR.

GEN.

FLUOR.

FL./FLR.

FURN.

FURR.

F.E.

F.D.

F.S.

FTG.

GA.

OUTSIDE DIAMETER (DIMENSION)

MECHANICAL

MASONRY OPENING

MISCELLANEOUS

MINIMUM/MINUTE

NOT TO SCALE

NOT IN CONTRACT

NUMBER

OFFICE

OPENING

PAINT

OVERHEAD

ON CENTER

MAXIMUM

MASONRY

MEMBRANE

NOMINAL

NORTH

SHEET

SAFETY

SECTION

SCHEDULE

SOLID CORE

SQUARE

SIMILAR

SPECIFICATIONS

TOP OF PIER

STEEL

STORAGE

TOTAL LOAD

TOP OF DECK

TOP OF STEEL

STAINLESS STEEL

TOP OF FOOTING

STORAGE CLOSET

TOP OF MASONRY

TOP OF SLAB

SQUARE FOOT

N.I.C.

O.H.

OFF.

OPNG.

O.C.

O.D.

NO.

N.T.S.

PT.

MEMB.

MECH.

MAX.

MAS.

M.O.

MISC.

MIN.

NOM.

N

SCHED.

SPEC.

T.O.STL.

T.O.D.

T.O.M.

ST. CL.

STOR.

STL.

T.O.S.

T.O.P.

T.O.F.

T.L.

SHT.

SFTY.

SECT.

S.C.

SQ.

SIM.

S.S.

S.F.

XX

XXX

BUILDING CHARACTERISTICS

PER CHAPTER 16

AREA OF BUILDING

NUMBER OF STORIES

HEIGHT OF STRUCTURE

BUILDING DESIGN LOADS

ROOF CONSTRUCTION

(INCLUDING SUPPORTING BEAMS AND JOISTS)

FLOOR CONSTRUCTION

(INCLUDING SUPPORTING BEAMS AND JOISTS)

NON BEARING WALLS & PARTITIONS (TABLE 602)

EXTERIOR

INTERIOR (e)

STRUCTURAL FRAME (a)

(INCLUDING COLUMNS, GIRDERS, TRUSSES)

EXIT ACCESS CORRIDORS (1020.1)

SHAFTS (713.4)

FIRE PARTITIONS (708.3)

FIRE BARRIERS (707.3.10)

FIRE WALLS (706.4)

BEARING WALLS

EXTERIOR (f)

INTERIOR

PER TABLE (601) SECTION (602)

AUTOMATIC SPRINKLER SYSTEMS

SPECIAL NOTES

HEAVY 250 PSF LL

GROUND SNOW LOADS 30 PSF

BASIC WIND SPEED 130 MPH (EXPOSURE "B")

APPLICABLE CODES AND STANDARDS

OCEAN COUNTY

LIGHT 125 PSF LL

EX

IS

TI

NG

N

O C

HA

NG

E

EX

IS

TI

NG

N O C

HA

NG

E

TOMS RIVER

NEW JERSEY

S-1 (EXISTING - NO CHANGE)

(EXISTING NO CHANGE)

2B (EXISTING - NO CHANGE)

17,500 (EXISTING - NO CHANGE)

55'-0" (EXISTING - NO CHANGE)

1 STORY (EXISTING - NO CHANGE)

(EXISTING - NO CHANGE)

(EXISTING - NO CHANGE)

ROOF LOAD 20 PSF LL MIN.

1 PROJECT DATA & CODE REVIEWCOVER

6 FLOOR PLAN & ROOF PLANA-1.0

EXTERIOR ELEVATIONS & DETAILSA-2.07

ROOF DETAILSA-2.1

INDEX OF DRAWINGS

SCOPE OF WORK

AERIAL VIEW

3 EXISTING CONDITION PHOTOGRAPHSD-2.0

2 DEMOLITION, FLOOR PLAN & ROOF PLAND-1.0

OCEAN COUNTY BOARD OF CHOSEN COMMISSIONERS

A

CE

R

O

EYS

CN

E W

O

E

U

TN Y

N

J

EXISTING CONDITION PHOTOGRAPHSD-2.1

EXISTING WAREHOUSE

N

EXISTING ENTITY TO REMAIN

CHESTNUT STREET

UNIFORM CONSTRUCTION CODE STATE OF NEW JERSEY, LATEST EDITION AND ALL OF ITS

SUBCODES AND AMENDMENTS (N.J. REHAB SUB CODE)

NATIONAL STANDARD PLUMBING CODE / 2021

ASHRAE 90.1 - 2019 (COMMERCIAL)

INTERNATIONAL FUEL GAS CODE / 2021

INTERNATIONAL MECHANICAL CODE / 2021

INTERNATIONAL RESIDENTIAL CODE / 2021

NATIONAL ELECTRIC CODE / 2020

ANSI A117.1-2017

WFCM (WOOD FRAMED CONSTRUCTION) HIGH WIND AREAS FOR ONE & TWO FAMILY DWELLINGS

INTERNATIONAL BUILDING CODE / 2021

INTERNATIONAL ENERGY CONSERVATION CODE - NJ ED, 2021

NEW JERSEY REHABILITATION SUBCODE 5:23-6

GUIDELINES FOR DESIGN AND CONSTRUCTION OF OUTPATIENT FACILITIES - 2018 EDITION

ALL ALTERATIONS WORK TO COMPLY WITH ALL APPLICABLE PROVISIONS OF NJAC

SECTION 5:23-6.6 OF THE NJUCC

FRANK SADEGHI DIRECTOR

JENNIFIER BACCHIONE DEPUTY DIRECTOR

ROBERT S. ARACE COMMISSIONER

SAM ELLENBOGEN COMMISSIONER

RAY GORMLEY COMMISSIONER

MICHAEL J. FIURE ADMINISTRATOR

TRACY MAKSEL, PhD DEPUTY ADMINISTRATOR

JOSEPH MEYERS SUPERINTENDENT OF BUILDINGS AND GROUNDS

RYAN REILLY CHIEF OF ADMINISTRATIVE SERVICES

ALL WORK MUST BE PROTECTED. ANY SUCH WORK DAMAGED IN THE COURSE OF

CONSTRUCTION WILL BE REPAIRED OR REPLACED BY THE CONTRACTOR AT HIS EXPENSE.

ALL ITEMS THAT ARE DAMAGED AND NOT REUSABLE SHALL BE REPLACED BY THE

CONTRACTOR AT HIS OWN EXPENSE.

WHERE THERE MAY BE A CONFLICT BETWEEN THE DRAWINGS AND THE ACTUAL FIELD

CONDITIONS THE CONTRACTOR SHALL NOTIFY THE ARCHITECTS WHO WILL MAKE THE

NECESSARY REVISIONS.

FIELD CHECK ALL DIMENSIONS PRIOR TO THE START OF CONSTRUCTION.

ALL EXISTING UTILITIES IN CONFLICT WITH THE WORK SHALL BE TURNED OFF BY THE

CONTRACTOR / UTILITY COMPANIES PRIOR TO START OF DEMOLITION / CONSTRUCTION.

THE GENERAL CONTRACTOR SHOULD BE RESPONSIBLE FOR ALL THE TRADES INVOLVED IN

THE PROJECT.

THE CONTRACTOR SHALL EXAMINE ALL EXISTING CONDITIONS PRIOR TO BIDDING AND

STARTING CONSTRUCTION & TAKE PHOTOGRAPHS OF ALL EXISTING CONDITIONS.

ALL TRADES TO DO THEIR OWN CUTTING AND PATCHING UNLESS OTHERWISE NOTED ON

THE DRAWINGS.

ALL TRADES TO COORDINATE THEIR WORK SO THERE WILL BE NO DUPLICATION OF WORK.

ALL ITEMS MARKED ON THE DRAWINGS TO BE REMOVED SHALL ALSO MEAN PATCH TO

MATCH SURROUNDING CONDITIONS.

AT THE END OF EACH WORKING DAY THE CONTRACTOR SHALL REMOVE ALL CONSTRUCTION

RUBBLE FROM THE SITE.

THE CONTRACTOR SHALL MAINTAIN THE THERMAL AND ACOUSTICAL PROPERTIES OF THE

BUILDING DURING CONSTRUCTION.

14.

13.

12.

11.

10.

7.

8.

9.

DO NOT SCALE DRAWINGS

PLANS TO CONFORM WITH THE STRUCTURE REQUIREMENTS OF THE INTERNATIONAL

BUILDING CODE, LATEST EDITION.

6.

5.

3.

4.

2.

1.

G.C. COORDINATION

THE PROJECT IS A SINGLE BID - ALL TRADES, THE G.C. TO COORDINATE ALL

DRAWINGS WITH THEIR SUB CONTRACTORS.

THE GENERAL CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL DRAWINGS

BETWEEN ALL TRADES. WHERE THERE MAYBE OVERLAPPING RESPONSIBILITIES.

2 STORIES (EXISTING - NO CHANGE)

ALTERNATE DETAILS DOORS & WINDOWSA-3.0

EXISTING CONDITION PHOTOGRAPHSD-2.2

BUILDINGS & GROUNDS WAREHOUSE #65 EXTERIOR RENOVATIONS FOR OCEAN COUNTY

1. PROVIDE AND INSTALL NEW METAL ROOF OVER EXISTING ROOF.

2. PROVIDE AND INSTALL NEW METAL GUTTERS AND METAL DOWNSPOUTS.

3. PROVIDE AND INSTALL PVC BOOT CONNECTION FROM EXISTING LEADERS TO EXISTING STORM DRAIN

SYSTEM.

4. PROVIDE NEW SPLASH BLOCK AT ALL DOWNSPOUTS THAT ARE NOT TIED TO EXISTING STORM DRAIN

SYSTEM.

5. PROVIDE AND INSTALL NEW METAL SOFFITS.

6. EXISTING ELECTRICAL, HVAC, AND PLUMBING TO REMAIN.

7. RAISE OR EXTEND EXISTING ROOF TOP MECHANICAL EQUIPMENT, VENTS, ETC AS REQUIRED. TO INSTALL

NEW ROOFING SYSTEM AND MEET CODE.

8. REMOVE AND REPLACE EXISTING METAL SIDING FROM FINISH FLOOR/GRADE TO 3'-0" ABOVE EXISTING

FINISHED FLOOR. REFER TO FLOOR PLAN AND EXTERIOR ELEVATIONS FOR EXTEND OF REMOVAL AND

REPLACEMENT.

BASE BID

ALTERNATE #1 - CONTRACTOR SHALL STATE THE AMOUNT BEING ADDED TO THE BASE BID TO REMOVE AND REPLACE EXISTING EXTERIOR DOORS (14). REFER TO SHEET A-1.0 FOR DOOR LOCATIONS AND SHEET A-3.0 FOR DOOR DETAILS.

ALTERNATE #2 - CONTRACTOR SHALL STATE THE AMOUNT BEING ADDED TO THE BASE BID TO REMOVE AND REPLACE EXISTING EXTERIOR WINDOWS (19). REFER TO SHEET A-1.0 FOR DOOR LOCATIONS AND SHEET A-3.0 FOR

WINDOW DETAILS.

ALTERNATE #3 - CONTRACTOR SHALL STATE THE AMOUNT BEING ADDED TO THE BASE BID TO POWER WASH AND

PAINT THE EXISTING EXTERIOR OF THE BUILDING. INCLUDING COILING DOORS AND FRAMES.

BID ALTERNATES

THE BUILDING IS EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM. NO MODIFICATIONS ARE BEING

MADE TO THE EXISTING SYSTEM.

THE S-1 AREA DOES NOT EXCEED 12,000 SF NOR ARE COMMERCIAL VEHICLES BEING STORED,

THEREFORE AUTOMATIC SPRINKLER SYSTEMS ARE NOT REQUIRED AS PER SECTIONS

903.2.9 & 903.2.9.1

PROJECT DATA

& CODE REVIEW

1SK

MFY

COVER

JULY 28, 2026

YC25108

Drawn By

Chk'd By

Sheet No.

Project No.

OF

Sheet Title

YEZZI ASSOCIATES

INTERIORS

E-mail: info@yezziassociates.com

Tel: 732-240-3433 Fax: 732-240-3463

Toms River, N.J. 08754

Website: www.yezziassociates.com

ENGINEERING

18 Washington Street P.O. Box 1638

ARCHITECTURE

PLANNING

MANAGEMENT

O W

NE

R S

HI

P

O F

DO

CU

M

EN

TS

: T his d oc um en t, id ea s an d de si gn s inc or po ra te d he re in, a re in st ru me nt s of p ro fe ss ion al se rv ice a nd a re t he p ro pe rt y of

Y ez zi As so cia te s an d ar e no t to b e us ed , c op ie d or r ep ro du ce d in wh ole o r in pa rt w ith ou t ap pr ov al of

Y ez zi As so cia te s.

T he se d oc um en ts h av e be en r ev ie we d wi th t he c lie nt p rio r to b ei ng s ign ed a nd s ea le d by Y ez zi

As so cia te s to in su re c on fo rm an ce w ith c lie nt s sc op e of w or k.

Pr oj ec t

Project Bid Date

Revisions By Date

Seal

-NJArchitect No. C 7475 Planner No. 2368 Architect No. 019392 Architect No. 012739B Architect No. 7460 Architect No. 8475 Architect No. 5975 Architect No. 92394 Architect No. 5733 Architect No. 9787-005 Architect No. 39914 Architect No. 30262377

-NJ

-NY

-PA

-CT

-NC

-SC

-FL

-NV

-WISC

-NCARB

-AIA

Architect No. AI01544800 Architect No. 023995

-NJ

-NY

Massimo Francis Yezzi, Jr.

Philip J. Reina

Signature Not Valid Without Raised Seal Signature Date

Do Not Scale Drawings - Field check all dimensions prior to start of construction.

BU

IL

DI

NG

S

G R O

UN

DS

W

AR

EH

O

US

E #6

E

XT

ER

IO

R R

EN

O V

AT

IO

NS

FO

R O

CE

AN

C O

UN

TY

CH

ES

TN

UT

S

TR

EE

T O

CE

AN

C

O

UN

TY

TO

M S

R

IV

ER

NE

W J

ER

S

EY

YEZZI INTERIORS

Tel: 732-240-3432

Sara Reidmiller Int. Designer No. ID0050100 -NJ

-NCIDQInt. Designer No. 37166

Samantha Karaczun Int. Designer No. ID0052100 -NJ

-NCIDQInt. Designer No. 240207

BG2026-007

AutoCAD SHX Text

'-0

'-6

0' -6

96'-6" ± 208'-10"

18 1 2" METAL ROOFING RIDGE SPAN24" METAL ROOFING RIDGE SPAN

± 305'-4"

SYMBOL LEGEND

EXISTING TO BE REMOVED

X EXISTING PHOTO LOCATION & DIRECTION CALLOUT

THIS DEMOLITION PLAN INDICATED ON THIS DRAWING ARE FOR REFERENCE ONLY TO INDICATE THE EXISTING BUILDING CONDITIONS AT THE TIME OF OUR FIELD INSPECTION. ALL DEMOLITION REQUIRED TO SUCCESSFULLY COMPLETE THIS PROJECT SHALL BE INCLUDED IN THE GENERAL CONTRACTORS SCOPE OF WORK.

NOTE

GENERAL SELECTIVE DEMOLITION NOTES

PREPARATION

· PROVIDE, ERECT, AND MAINTAIN TEMPORARY BARRIERS AND SECURITY DEVICES.

· NOTIFY OWNER OF WORK WHICH MAY AFFECT THEIR PROPERTY, POTENTIAL NOISE, UTILITY

OUTAGE, OR DISRUPTION. COORDINATE ALL WORK WITH OWNER.

· PREVENT MOVEMENT OR SETTLEMENT OF ADJACENT STRUCTURES. PROVIDE BRACING AND

SHORING AS REQUIRED.

· PROTECT EXISTING LANDSCAPING MATERIALS AND STRUCTURES TO REMAIN.

· ERECT AND MAINTAIN WEATHERPROOF AIRTIGHT CLOSURES FOR EXTERIOR OPENINGS.

· ERECT AND MAINTAIN TEMPORARY PARTITIONS TO PREVENT SPREAD OF DUST, ODORS AND NOISE

TO PERMIT CONTINUED OWNER OCCUPANCY.

· PROTECT EXISTING ITEMS INDICATED TO REMAIN.

· NEW ROOFING SYSTEM INSTALLED ON TOP OF EXISTING SYSTEM (TYP.)

TAGGED DEMOLITION NOTES

REMOVE & REPLACE EXISTING GUTTERS, DOWNSPOUTS AND BOOTS AS INDICATED ON DRAWINGS AND REPLACE WITH NEW - MATCH

EXISTING, TIE TO STORM SYSTEM (TYP.)

EXISTING ROOF PENETRATION TO REMAIN, RESEAL AND EXTEND AS REQUIRED BY CODE TO ACCOMMODATE NEW ROOF SYSTEM

(TYP. OF EACH)

EXISTING ROOF SYSTEM TO REMAIN - PROVIDE NEW ROOF OVERLAY - SEE ROOF PLAN FOR ADDITIONAL INFORMATION (TYP.)

1 1 1 1 1 1

1 1 1 1 1 1

ALTERNATE #1 - REMOVE EXISTING DOORS, HARDWARE, AND FRAME AND REPLACED WITH NEW. REPAIR/PATCH SUROUNDING CONDITIONS AS

REQUIRED FOR NEW WORK. (TYP.)

SELECTIVE DEMOLITION:

· DEMOLISH AND REMOVE COMPONENTS IN ORDERLY AND CAREFUL MANNER, IN SEQUENCE OUTLINED IN SUBMITTED AND

APPROVED SCHEDULE.

· PROTECT EXISTING SUPPORTING STRUCTURAL MEMBERS.

CLEAN UP:

· REMOVE DEMOLISHED MATERIALS FROM SITE AS WORK PROGRESSES.

· LEAVE AREAS OF WORK IN CLEAN CONDITION.

· DISPOSE OF ALL DEBRIS IN ACCORDANCE WITH ALL STATE AND MUNICIPAL REQUIREMENTS. PROVIDE LOAD TICKETS WHERE

APPLICABLE.

EXISTING TO REMAINE

S

LO

PE

0.

/1

S

LO

PE

0.

/1

S

LO

PE

0.

/1

S

LO

PE

0.

/1

S

LO

PE

0.

/1

S

LO

PE

0.

/1

S

LO

PE

0.

/1

S

LO

PE

0.

/1

ALTERNATE #2 - REMOVE AND REPLACE ALL WINDOWS (19) - REPAIR/REPLACE ANY ROTTED SILL, ETC. MATCH EXISTING CONDITIONS.

(TYP.)

RIDGE RIDGE RIDGE

REMOVE EXIST'G ROOF RIDGE VENT AND REPLACE WITH NEW AS PART OF NEW ROOFING OVERLAY SYSTEM (TYP.)

NEW METAL ROOF TO BE

INSTALLED OVER EXISTING

SCALE:

ROOF DEMOLITION PLAN

D-1.0

3/32 = 1'-0"

SCALE:

DEMOLITION FLOOR PLAN

D-1.0

3/32 = 1'-0"

DASHED LINES INDICATES

FACE OF BUILDING BELOW

1'-

" EXISTING BUILDING, INCLUDING

CONC. FLOOR SLAB, HVAC,

PLUMBING & ELECTRICAL TO

REMAIN (TYP.)

6 6

E E E E E E 5 5

77777

7 7 7 7 77 7 7

± 305'-0"

DASHED LINES INDICATES ROOF

OVERHANG & GUTTER ABOVE

6 6 6

55 5 5 5 5 5 5 5

REMOVE PORTION OF EXISTING METAL WALL PANELS FROM FINISH FLOOR/CONC. APRON TO 3'-0" A.F.F. AND REPLACE WITH METAL PANEL AS SPECIFIED TO MATCH SURROUNDING CONDITIONS. REFER TO DETAIL 6/A-2.0 FOR ADDITIONAL INFORMATION. (TYP.)

ALTERNATE #3 - EXISTING METAL WALL PANELS TO REMAIN, GC. TO POWER WASH AND PAINT EXISTING BUILDING. PRIMED AND

PAINTED 2 COATS (EXTERIOR) (TYP.)

5 5

DEMOLITION FLOOR PLAN

& ROOF PLAN

2SK

MFY

D-1.0

JULY 28, 2026

YC25108

Drawn By

Chk'd By

Sheet No.

Project No.

OF

Sheet Title

YEZZI ASSOCIATES

INTERIORS

E-mail: info@yezziassociates.com

Tel: 732-240-3433 Fax: 732-240-3463

Toms River, N.J. 08754

Website: www.yezziassociates.com

ENGINEERING

18 Washington Street P.O. Box 1638

ARCHITECTURE

PLANNING

MANAGEMENT

O W

NE

R S

HI

P

O F

DO

CU

M

EN

TS

: T his d oc um en t, id ea s an d de si gn s inc or po ra te d he re in, a re in st ru me nt s of p ro fe ss ion al se rv ice a nd a re t he p ro pe rt y of

Y ez zi As so cia te s an d ar e no t to b e us ed , c op ie d or r ep ro du ce d in wh ole o r in pa rt w ith ou t ap pr ov al of

Y ez zi As so cia te s.

T he se d oc um en ts h av e be en r ev ie we d wi th t he c lie nt p rio r to b ei ng s ign ed a nd s ea le d by Y ez zi

As so cia te s to in su re c on fo rm an ce w ith c lie nt s sc op e of w or k.

Pr oj ec t

Project Bid Date

Revisions By Date

Seal

-NJArchitect No. C 7475 Planner No. 2368 Architect No. 019392 Architect No. 012739B Architect No. 7460 Architect No. 8475 Architect No. 5975 Architect No. 92394 Architect No. 5733 Architect No. 9787-005 Architect No. 39914 Architect No. 30262377

-NJ

-NY

-PA

-CT

-NC

-SC

-FL

-NV

-WISC

-NCARB

-AIA

Architect No. AI01544800 Architect No. 023995

-NJ

-NY

Massimo Francis Yezzi, Jr.

Philip J. Reina

Signature Not Valid Without Raised Seal Signature Date

Do Not Scale Drawings - Field check all dimensions prior to start of construction.

BU

IL

DI

NG

S

G R O

UN

DS

W

AR

EH

O

US

E #6

E

XT

ER

IO

R R

EN

O V

AT

IO

NS

FO

R O

CE

AN

C O

UN

TY

CH

ES

TN

UT

S

TR

EE

T O

CE

AN

C

O

UN

TY

TO

M S

R

IV

ER

NE

W J

ER

S

EY

YEZZI INTERIORS

Tel: 732-240-3432

Sara Reidmiller Int. Designer No. ID0050100 -NJ

-NCIDQInt. Designer No. 37166

Samantha Karaczun Int. Designer No. ID0052100 -NJ

-NCIDQInt. Designer No. 240207

BG2026-007

1 2 3 4

5 6 7 8

9 10 11 12

SCALE:

EXISTING CONDITIONS WAREHOUSE PHOTOGRAPHS

D-2.0

N.T.S.

EXISTING CONDITION

PHOTOGRAPHS

3SK

MFY

D-2.0

BASE BID EXISTING ROOF PENETRATION

TO REMAIN, RESEAL, REFLASH AND

EXTEND AS REQUIRED BY CODE TO

ACCOMMODATE NEW ROOF SYSTEM (TYP.)

BASE BID EXISTING ROOF PENETRATION TO

REMAIN, RESEAL, REFLASH, AND EXTEND

AS REQUIRED BY CODE TO ACCOMMODATE

NEW ROOF SYSTEM (TYP.)

BASE BID EXISTING ROOF SYSTEM TO

REMAIN - PREPARE SURFACE FOR NEW

METAL ROOF OVERLAY - SEE ROOF PLAN

FOR ADDITIONAL INFORMATION (TYP.)

BASE BID EXISTING ROOF SYSTEM TO

REMAIN - PREPARE SURFACE FOR NEW

METAL ROOF OVERLAY - SEE ROOF PLAN

FOR ADDITIONAL INFORMATION (TYP.)

BASE BID EXISTING ROOF SYSTEM TO

REMAIN - PREPARE SURFACE FOR NEW

METAL ROOF OVERLAY - SEE ROOF PLAN

FOR ADDITIONAL INFORMATION (TYP.)

BASE BID EXISTING ROOF SYSTEM TO

REMAIN - PREPARE SURFACE FOR NEW

METAL ROOF OVERLAY - SEE ROOF PLAN

FOR ADDITIONAL INFORMATION (TYP.)

BASE BID EXISTING ROOF SYSTEM TO

REMAIN - PREPARE SURFACE FOR NEW

METAL ROOF OVERLAY - SEE ROOF PLAN

FOR ADDITIONAL INFORMATION (TYP.)

BASE BID EXISTING ROOF SYSTEM TO

REMAIN - PREPARE SURFACE FOR NEW

METAL ROOF OVERLAY - SEE ROOF PLAN

FOR ADDITIONAL INFORMATION (TYP.)

BASE BID EXISTING ROOF PENETRATION

TO REMAIN, RESEAL, REFLASH AND

EXTEND AS REQUIRED BY CODE TO

ACCOMMODATE NEW ROOF SYSTEM (TYP.)

BASE BID EXISTING ROOF PENETRATION

TO REMAIN, RESEAL, REFLASH AND

EXTEND AS REQUIRED BY CODE TO

ACCOMMODATE NEW ROOF SYSTEM

(TYP.)

BASE BID EXISTING ROOF PENETRATION

TO REMAIN, RESEAL, REFLASH AND

EXTEND AS REQUIRED BY CODE TO

ACCOMMODATE NEW ROOF SYSTEM (TYP.)

BASE BID ALL EXISTING METAL DUCTS TO

BE CLEANED & PAINTED. (1) COAT RUST

INHIBITOR, (2) COATS FINISH PAINT

SUITABLE FOR EXTERIOR METAL (TYP.)

BASE BID ALL EXISTING METAL DUCTS TO

BE CLEANED & PAINTED. (1) COAT RUST

INHIBITOR, (2) COATS FINISH PAINT

SUITABLE FOR EXTERIOR METAL (TYP.)

JULY 28, 2026

YC25108

Drawn By

Chk'd By

Sheet No.

Project No.

OF

Sheet Title

YEZZI ASSOCIATES

INTERIORS

E-mail: info@yezziassociates.com

Tel: 732-240-3433 Fax: 732-240-3463

Toms River, N.J. 08754

Website: www.yezziassociates.com

ENGINEERING

18 Washington Street P.O. Box 1638

ARCHITECTURE

PLANNING

MANAGEMENT

O W

NE

R S

HI

P

O F

DO

CU

M

EN

TS

: T his d oc um en t, id ea s an d de si gn s inc or po ra te d he re in, a re in st ru me nt s of p ro fe ss ion al se rv ice a nd a re t he p ro pe rt y of

Y ez zi As so cia te s an d ar e no t to b e us ed , c op ie d or r ep ro du ce d in wh ole o r in pa rt w ith ou t ap pr ov al of

Y ez zi As so cia te s.

T he se d oc um en ts h av e be en r ev ie we d wi th t he c lie nt p rio r to b ei ng s ign ed a nd s ea le d by Y ez zi

As so cia te s to in su re c on fo rm an ce w ith c lie nt s sc op e of w or k.

Pr oj ec t

Project Bid Date

Revisions By Date

Seal

-NJArchitect No. C 7475 Planner No. 2368 Architect No. 019392 Architect No. 012739B Architect No. 7460 Architect No. 8475 Architect No. 5975 Architect No. 92394 Architect No. 5733 Architect No. 9787-005 Architect No. 39914 Architect No. 30262377

-NJ

-NY

-PA

-CT

-NC

-SC

-FL

-NV

-WISC

-NCARB

-AIA

Architect No. AI01544800 Architect No. 023995

-NJ

-NY

Massimo Francis Yezzi, Jr.

Philip J. Reina

Signature Not Valid Without Raised Seal Signature Date

Do Not Scale Drawings - Field check all dimensions prior to start of construction.

BU

IL

DI

NG

S

G R O

UN

DS

W

AR

EH

O

US

E #6

E

XT

ER

IO

R R

EN

O V

AT

IO

NS

FO

R O

CE

AN

C O

UN

TY

CH

ES

TN

UT

S

TR

EE

T O

CE

AN

C

O

UN

TY

TO

M S

R

IV

ER

NE

W J

ER

S

EY

YEZZI INTERIORS

Tel: 732-240-3432

Sara Reidmiller Int. Designer No. ID0050100 -NJ

-NCIDQInt. Designer No. 37166

Samantha Karaczun Int. Designer No. ID0052100 -NJ

-NCIDQInt. Designer No. 240207

BG2026-007

BASE BID NEW

FLASHING

BASE BID NEW

FLASHING

9 10 11 12

SCALE:

EXISTING CONDITIONS WAREHOUSE PHOTOGRAPHS

D-2.1

N.T.S.

EXISTING CONDITION

PHOTOGRAPHS

4SK

MFY

D-2.1

ALT. #1 REPAIR DAMAGED GWB, TRIM,

PANELS, ETC. CAUSED BY THE

REPLACEMENT OF THE DOOR/FRAME,

PRIME AND PAINT TO MATCH

SURROUNDING CONDITIONS (TYP.)

ALT. #1 REMOVE EXISTING DOOR AND FRAME

AND REPLACED WITH NEW - SEE FLOOR PLANS

FOR ADDITIONAL INFORMATION (TYP.)

BASE BID NEW ALUMINUM SOFFIT ENCLOSURE AT ENTIRE SIDE

OF THE BUILDING. CONTRACTOR TO VERIFY ALL EXISTING

STRUCTURAL SIZES AND SPACING IN THE FIELD (TYP.)

JULY 28, 2026

YC25108

Drawn By

Chk'd By

Sheet No.

Project No.

OF

Sheet Title

YEZZI ASSOCIATES

INTERIORS

E-mail: info@yezziassociates.com

Tel: 732-240-3433 Fax: 732-240-3463

Toms River, N.J. 08754

Website: www.yezziassociates.com

ENGINEERING

18 Washington Street P.O. Box 1638

ARCHITECTURE

PLANNING

MANAGEMENT

O W

NE

R S

HI

P

O F

DO

CU

M

EN

TS

: T his d oc um en t, id ea s an d de si gn s inc or po ra te d he re in, a re in st ru me nt s of p ro fe ss ion al se rv ice a nd a re t he p ro pe rt y of

Y ez zi As so cia te s an d ar e no t to b e us ed , c op ie d or r ep ro du ce d in wh ole o r in pa rt w ith ou t ap pr ov al of

Y ez zi As so cia te s.

T he se d oc um en ts h av e be en r ev ie we d wi th t he c lie nt p rio r to b ei ng s ign ed a nd s ea le d by Y ez zi

As so cia te s to in su re c on fo rm an ce w ith c lie nt s sc op e of w or k.

Pr oj ec t

Project Bid Date

Revisions By Date

Seal

-NJArchitect No. C 7475 Planner No. 2368 Architect No. 019392 Architect No. 012739B Architect No. 7460 Architect No. 8475 Architect No. 5975 Architect No. 92394 Architect No. 5733 Architect No. 9787-005 Architect No. 39914 Architect No. 30262377

-NJ

-NY

-PA

-CT

-NC

-SC

-FL

-NV

-WISC

-NCARB

-AIA

Architect No. AI01544800 Architect No. 023995

-NJ

-NY

Massimo Francis Yezzi, Jr.

Philip J. Reina

Signature Not Valid Without Raised Seal Signature Date

Do Not Scale Drawings - Field check all dimensions prior to start of construction.

BU

IL

DI

NG

S

G R O

UN

DS

W

AR

EH

O

US

E #6

E

XT

ER

IO

R R

EN

O V

AT

IO

NS

FO

R O

CE

AN

C O

UN

TY

CH

ES

TN

UT

S

TR

EE

T O

CE

AN

C

O

UN

TY

TO

M S

R

IV

ER

NE

W J

ER

S

EY

YEZZI INTERIORS

Tel: 732-240-3432

Sara Reidmiller Int. Designer No. ID0050100 -NJ

-NCIDQInt. Designer No. 37166

Samantha Karaczun Int. Designer No. ID0052100 -NJ

-NCIDQInt. Designer No. 240207

BG2026-007

BASE BID REMOVE

EXISTING WIRE MESH

(TYP.)

BASE BID REMOVE

EXISTING WIRE MESH (TYP.)

BASE BID REMOVE PORTION OF EXISTING METAL

SIDING FROM FINISH FLOOR/BOTTOM OF

EXISTING PANEL TO 3'-0" ABOVE FINISHED

FLOOR AND REPLACE WITH NEW METAL PANEL

AS SPECIFIED. (TYP.)

ALT. #3 EXISTING METAL WALL PANELS

TO REMAIN, POWER WASH AND PAINT

(PRIMED AND PAINTED 2 COATS) (TYP.)

ALT. #3 EXISTING METAL WALL PANELS

TO REMAIN, POWER WASH AND PAINT

(PRIMED AND PAINTED 2 COATS) (TYP.)

ALT. #3 EXISTING METAL WALL PANELS

TO REMAIN, POWER WASH AND PAINT

(PRIMED AND PAINTED 2 COATS) (TYP.)

ALT. #3 EXISTING METAL WALL PANELS

TO REMAIN, POWER WASH AND PAINT

(PRIMED AND PAINTED 2 COATS) (TYP.)

ALT. #3 EXISTING METAL WALL PANELS

TO REMAIN, POWER WASH AND PAINT

(PRIMED AND PAINTED 2 COATS) (TYP.)

ALT. #1 REMOVE EXISTING DOOR AND FRAME

AND REPLACED WITH NEW - SEE FLOOR PLANS

FOR ADDITIONAL INFORMATION (TYP.)

ALT. #1 REMOVE EXISTING DOOR AND FRAME

AND REPLACED WITH NEW - SEE FLOOR PLANS

FOR ADDITIONAL INFORMATION (TYP.)

ALT. #1 REMOVE EXISTING DOOR AND FRAME

AND REPLACED WITH NEW - SEE FLOOR PLANS

FOR ADDITIONAL INFORMATION (TYP.)

ALT. #1 REMOVE EXISTING DOOR AND FRAME

AND REPLACED WITH NEW - SEE FLOOR PLANS

FOR ADDITIONAL INFORMATION (TYP.)

ALT. #2 REMOVE EXISTING WINDOWS AND

FRAMES AND REPLACED WITH NEW - SEE FLOOR

PLANS FOR ADDITIONAL INFORMATION (TYP.)

ALT. #2 REMOVE EXISTING WINDOWS AND

FRAMES AND REPLACED WITH NEW - SEE FLOOR

PLANS FOR ADDITIONAL INFORMATION (TYP.)

ALT. #2 REMOVE

EXISTING WINDOWS AND

FRAMES AND REPLACED

WITH NEW - SEE FLOOR

PLANS FOR ADDITIONAL

INFORMATION (TYP.)

ALT. #2 REMOVE EXISTING WINDOWS AND

FRAMES AND REPLACED WITH NEW - SEE FLOOR

PLANS FOR ADDITIONAL INFORMATION (TYP.)

9 10 11 12

SCALE:

EXISTING CONDITIONS WAREHOUSE PHOTOGRAPHS

D-2.2

N.T.S.

EXISTING CONDITION

PHOTOGRAPHS

5SK

MFY

D-2.2

JULY 28, 2026

YC25108

Drawn By

Chk'd By

Sheet No.

Project No.

OF

Sheet Title

YEZZI ASSOCIATES

INTERIORS

E-mail: info@yezziassociates.com

Tel: 732-240-3433 Fax: 732-240-3463

Toms River, N.J. 08754

Website: www.yezziassociates.com

ENGINEERING

18 Washington Street P.O. Box 1638

ARCHITECTURE

PLANNING

MANAGEMENT

O W

NE

R S

HI

P

O F

DO

CU

M

EN

TS

: T his d oc um en t, id ea s an d de si gn s inc or po ra te d he re in, a re in st ru me nt s of p ro fe ss ion al se rv ice a nd a re t he p ro pe rt y of

Y ez zi As so cia te s an d ar e no t to b e us ed , c op ie d or r ep ro du ce d in wh ole o r in pa rt w ith ou t ap pr ov al of

Y ez zi As so cia te s.

T he se d oc um en ts h av e be en r ev ie we d wi th t he c lie nt p rio r to b ei ng s ign ed a nd s ea le d by Y ez zi

As so cia te s to in su re c on fo rm an ce w ith c lie nt s sc op e of w or k.

Pr oj ec t

Project Bid Date

Revisions By Date

Seal

-NJArchitect No. C 7475 Planner No. 2368 Architect No. 019392 Architect No. 012739B Architect No. 7460 Architect No. 8475 Architect No. 5975 Architect No. 92394 Architect No. 5733 Architect No. 9787-005 Architect No. 39914 Architect No. 30262377

-NJ

-NY

-PA

-CT

-NC

-SC

-FL

-NV

-WISC

-NCARB

-AIA

Architect No. AI01544800 Architect No. 023995

-NJ

-NY

Massimo Francis Yezzi, Jr.

Philip J. Reina

Signature Not Valid Without Raised Seal Signature Date

Do Not Scale Drawings - Field check all dimensions prior to start of construction.

BU

IL

DI

NG

S

G R O

UN

DS

W

AR

EH

O

US

E #6

E

XT

ER

IO

R R

EN

O V

AT

IO

NS

FO

R O

CE

AN

C O

UN

TY

CH

ES

TN

UT

S

TR

EE

T O

CE

AN

C

O

UN

TY

TO

M S

R

IV

ER

NE

W J

ER

S

EY

YEZZI INTERIORS

Tel: 732-240-3432

Sara Reidmiller Int. Designer No. ID0050100 -NJ

-NCIDQInt. Designer No. 37166

Samantha Karaczun Int. Designer No. ID0052100 -NJ

-NCIDQInt. Designer No. 240207

BG2026-007

ALT. #3 EXISTING METAL WALL PANELS

TO REMAIN, POWER WASH AND PAINT

(PRIMED AND PAINTED 2 COATS) (TYP.)

ALT. #3 EXISTING METAL WALL PANELS

TO REMAIN, POWER WASH AND PAINT

(PRIMED AND PAINTED 2 COATS) (TYP.)

ALT. #3 EXISTING METAL WALL PANELS

TO REMAIN, POWER WASH AND PAINT

(PRIMED AND PAINTED 2 COATS) (TYP.)

ALT. #3 EXISTING METAL WALL PANELS

TO REMAIN, POWER WASH AND PAINT

(PRIMED AND PAINTED 2 COATS) (TYP.)

ALT. #3 EXISTING METAL WALL PANELS

TO REMAIN, POWER WASH AND PAINT

(PRIMED AND PAINTED 2 COATS) (TYP.)

ALT. #3 EXISTING METAL WALL PANELS

TO REMAIN, POWER WASH AND PAINT

(PRIMED AND PAINTED 2 COATS) (TYP.)

BASE BID REMOVE PORTION OF EXISTING METAL SIDING

FROM FINISH FLOOR/BOTTOM OF EXISTING PANEL TO

3'-0" ABOVE FINISHED FLOOR AND REPLACE WITH NEW

METAL PANEL AS SPECIFIED. (TYP.) BASE BID REMOVE PORTION OF EXISTING METAL SIDING

FROM FINISH FLOOR/BOTTOM OF EXISTING PANEL TO

3'-0" ABOVE FINISHED FLOOR AND REPLACE WITH NEW

METAL PANEL AS SPECIFIED. (TYP.)

ALT. #1 REMOVE EXISTING DOOR AND FRAME

AND REPLACED WITH NEW - SEE FLOOR PLANS

FOR ADDITIONAL INFORMATION (TYP.)

ALT. #1 REMOVE EXISTING DOOR AND FRAME

AND REPLACED WITH NEW - SEE FLOOR PLANS

FOR ADDITIONAL INFORMATION (TYP.)

ALT. #1 REMOVE EXISTING DOOR AND FRAME

AND REPLACED WITH NEW - SEE FLOOR PLANS

FOR ADDITIONAL INFORMATION (TYP.)

ALT. #1 REMOVE EXISTING DOOR AND FRAME

AND REPLACED WITH NEW - SEE FLOOR PLANS

FOR ADDITIONAL INFORMATION (TYP.)

ALT. #1 REMOVE EXISTING DOOR AND FRAME

AND REPLACED WITH NEW - SEE FLOOR PLANS

FOR ADDITIONAL INFORMATION (TYP.)

ALT. #1 REMOVE EXISTING DOOR AND FRAME

AND REPLACED WITH NEW - SEE FLOOR PLANS

FOR ADDITIONAL INFORMATION (TYP.)

ALT. #1 REMOVE EXISTING DOOR AND FRAME

AND REPLACED WITH NEW - SEE FLOOR PLANS

FOR ADDITIONAL INFORMATION (TYP.)

ALT. #1 REMOVE EXISTING DOOR AND FRAME

AND REPLACED WITH NEW - SEE FLOOR PLANS

FOR ADDITIONAL INFORMATION (TYP.)

ALT. #2 REMOVE EXISTING WINDOWS AND

FRAMES AND REPLACED WITH NEW - SEE FLOOR

PLANS FOR ADDITIONAL INFORMATION (TYP.)

ALT. #2 REMOVE EXISTING WINDOWS AND

FRAMES AND REPLACED WITH NEW - SEE FLOOR

PLANS FOR ADDITIONAL INFORMATION (TYP.)

ALT. #2 REMOVE EXISTING WINDOWS AND

FRAMES AND REPLACED WITH NEW - SEE FLOOR

PLANS FOR ADDITIONAL INFORMATION (TYP.)

ALT. #2 REMOVE EXISTING WINDOWS AND

FRAMES AND REPLACED WITH NEW - SEE FLOOR

PLANS FOR ADDITIONAL INFORMATION (TYP.) ALT. #2 REMOVE EXISTING WINDOWS AND

FRAMES AND REPLACED WITH NEW - SEE FLOOR

PLANS FOR ADDITIONAL INFORMATION (TYP.)

ALT. #2 REMOVE EXISTING WINDOWS AND

FRAMES AND REPLACED WITH NEW - SEE FLOOR

PLANS FOR ADDITIONAL INFORMATION (TYP.)

AutoCAD SHX Text

'-0

'-6

0' -6

96'-6" ± 208'-10"

18 1 2" METAL ROOFING RIDGE SPAN24" METAL ROOFING RIDGE SPAN

± 305'-4"

S

LO

PE

0.

/1

A

A

B

BB B

B C

C

C C

C

ZONE 3 ZONE 3

ZONE 3 ZONE 3

C

ZONE 2 ZONE 2

ZONE 2

ZONE 2

ZONE 1

ZONE 1

DDDD D D D D D D

S

LO

PE

0.

/1

S

LO

PE

0.

/1

S

LO

PE

0.

/1

S

LO

PE

0.

/1

S

LO

PE

0.

/1

S

LO

PE

0.

/1

S

LO

PE

0.

/1

RIDGE RIDGE RIDGE

A-2.0

A-2.1

A-2.0

A-2.1

A-2.1

A-2.1

SIM.

A-2.1

SIM.

NEW ROOFING SYSTEM WILL BE CONSTRUCTED

OVER EXISTING ROOFING SYSTEM - SEE A-3.0

FOR ADDITIONAL DETAILS (TYP.)

SEE PHOTOS FOR

LOCATIONS OF

PENETRATIONS (TYP.)

E E E E E

EE E E E

NOTE:

ALL ZONES SIMILAR, G.C. TO SUBMIT

SHOP DRAWINGS FOR REVIEW

± 305'-0"

1'-

2 3 4 5 6

891011121314

EXISTING BUILDING TO

REMAIN (TYP.)

ALT. #3 - EXISTING OVERHEAD

DOOR TO REMAIN - CLEAN,

PRIME AND PAINT (TYP.)

ALT. #2 - REMOVE AND REPLACE

ALL WINDOW UNITS, COORDINATE

LOCATION IN FIELD WITH

ARCHITECT. REFER TO SHEET

A-3.0 FOR ADDITIONAL

INFORMATION (TYP. ALL WINDOWS)

DOWNSPOUT DOWNSPOUT DOWNSPOUT DOWNSPOUT DOWNSPOUT

DOWNSPOUT

DOWNSPOUT

DOWNSPOUT

DOWNSPOUT

DOWNSPOUT

DOWNSPOUT

DOWNSPOUT

SEE DRAWING A-2.1 FOR TYPICAL FRAMING DETAILS

FIELD COORDINATE WITH ROOF PLAN

ROOF FLAT AREA

21,800 SQFT

ROOF SLOPE ± 0.5/12

G.C. TO V.I.F. ALL DIMENSIONS

NEW ROOFING AS MANUFACTURED BY "IMETCO" OR

ARCHITECT APPROVED EQUAL WITH PREMIUM GRADE

FINISHES.

REFER TO SPECIFICATIONS FOR ADDITIONAL

INFORMATION (TYP.)

SUBMIT FULL SHOPS DRAWINGS AND SAMPLES FOR

REVIEW AND APPROVAL PRIOR TO CONSTRUCTION (TYP.)

1. THE OWNER WILL JET AND SCOPE THE EXISTING

STORM LINES PRIOR TO CONSTRUCTION. (TYP.)

2. OWNER WILL REMOVE AND REINSTALL ALL

LIGHTING AND SECURITY CAMERAS (TYP.)

IMPORTANT NOTES

TAGGED NOTES

A METAL ROOFING OVER STRUCTURAL RETROFIT SUB-FRAMING SYSTEM OVER EXISTING METAL ROOF AS SPECIFIED (TYP.)

· EXISTING METAL ROOF TO REMAIN, UNLESS INDICATED OTHERWISE.

· BASIS OF DESIGN:

METAL ROOFING, GUTTERS, DOWNSPOUTS, SNOW GUARDS: "IMETCO" OR ARCHITECT APPROVED EQUAL

STRUCTURAL RETROFIT SUB-FRAMING SYSTEM: "INTELLIFRAME RF (IRF)"

ROOF ZONE 1: 5.5" TALL IRF ZEE @ 5'-0" O.C. MAX.

ALUMINUM 16" ZIPRIB PANEL

ROOF ZONE 2: 5.5" TALL ROOF HUGGERS @ 4'-8" O.C. MAX.

ALUMINUM 16" ZIPRIB PANEL

ROOF ZONE 3: 3.25" TALL IRF HAT @ 2'-0" O.C. MAX.

2.25" TALL IRF HAT @ 2'-4" O.C. MAX.

ALUMINUM 16" ZIPRIB PANEL

· G.C. MUST SUBMIT A FULL SET OF COMPLETE ENGINEERED SHOP DRAWINGS FOR THE ROOF SUB-FRAMING SYSTEM, ROOFING PANEL SYSTEM, AND ALL RELATED ITEMS FOR REVIEW AND APPROVAL PRIOR TO ANY WORK BEING DONE

(TYP.)

· ALL SHOP DRAWINGS ARE TO BE SIGNED AND SEALED BY A P.E. LICENSED IN THE STATE OF NEW JERSEY (TYP.)

· THE SUB-RAFTER & SUB-PURLINS SIZING, SPACING, AND LOCATIONS MAY VARY FROM THAT SPECIFIED BASED ON FINAL

ENGINEERING BY THE MANUFACTURER (TYP.)

· G.C. TO INSTALL NEW RETROFIT ROOF SUB-FRAMING SYSTEM AND NEW ROOF PANEL SYSTEM, INCLUDING ALL RELATED

FASTENERS, TRIM, AND ACCESSORIES AS PER THE MANUFACTURER SPECIFICATIONS (TYP.)

· G.C. TO PROVIDE FASTENERS WITH SLEEVES WHEN THE EXISTING STAND-OFF CLIPS/THERMAL BLOCKS ARE GREATER

THAN 1-INCH (TYP.)

B 8"x8" .050 ALUMINUM GUTTER SYSTEM WITH (22) 6"x6" DOWNSPOUTS W/ 6"x6" OUTLET TUBES, ON EACH SIDE OF BUILDING - ROOFING MANUFACTURER TO PROVIDE NEW PVC CONNECTIONS WITH CLEAN OUTS FROM NEW LEADERS TO EXISTING DRAIN SYSTEM WHERE EXISTING DRAIN SYSTEM ALLOWS FOR TIE IN. ALL EXISTING SPLASH BLOCK LOCATIONS WILL RECEIVE NEW SPLASH BLOCKS. FIELD VERIFY EXACT LOCATION OF ALL DOWNSPOUTS WITH ARCHITECT / OWNER. SPACED 30'-0" O.C. MAXIMUM G.C. IS TO TIE DOWNSPOUTS INTO EXISTING UNDERGROUND

STORM WATER LINES (TYP.)

C EXISTING ROOF PENETRATION TO REMAIN, EXTEND AS REQUIRED BY CODE TO ACCOMMODATE NEW ROOF

SYSTEM (TYP.)

D NEW ALUMINUM SOFFIT ENCLOSURE AT ENTIRE SIDE OF THE BUILDING - SEE DETAILS FOR ADDITIONAL INFORMATION. CONTRACTOR TO VERIFY ALL EXISTING STRUCTURAL SIZES AND SPACING IN THE FIELD.

E

F ALL METAL OVERHEAD DOORS TO BE CLEANED & PAINTED. (1) COAT RUST INHIBITOR (2) COATS FINISH PAINT

SUITABLE FOR EXTERIOR METAL. (TYP.)

PROVIDE AND INSTALL SNOW GUARDS AS PER MANUFACTURER SPECIFICATIONS.

SCALE:

EXISTING WAREHOUSE DOOR LOCATION PLAN

A-1.0

3/32 = 1'-0"

SCALE:

ROOF PLAN

A-1.0

3/32 = 1'-0"

A-2.0

A-2.03

A-2.0

A-2.0

ALT. #2 - REMOVE AND REPLACE ALL

WINDOW UNITS, COORDINATE

LOCATION IN FIELD WITH ARCHITECT.

REFER TO SHEET A-3.0 FOR

ADDITIONAL INFORMATION (TYP. ALL

WINDOWS)

ALT. #2 - REMOVE AND REPLACE

ALL WINDOW UNITS, COORDINATE

LOCATION IN FIELD WITH

ARCHITECT. REFER TO SHEET

A-3.0 FOR ADDITIONAL

INFORMATION (TYP. ALL WINDOWS)

ALT. #2 - REMOVE AND REPLACE

ALL WINDOW UNITS, COORDINATE

LOCATION IN FIELD WITH

ARCHITECT. REFER TO SHEET

A-3.0 FOR ADDITIONAL

INFORMATION (TYP. ALL WINDOWS)

ALT. #3 - EXISTING OVERHEAD

DOOR TO REMAIN - CLEAN,

PRIME AND PAINT (TYP.)

ALT. #3 - EXISTING OVERHEAD

DOOR TO REMAIN - CLEAN,

PRIME AND PAINT (TYP.)

FLOOR PLAN &

ROOF PLAN

6SK

MFY

A-1.0

JULY 28, 2026

YC25108

Drawn By

Chk'd By

Sheet No.

Project No.

OF

Sheet Title

YEZZI ASSOCIATES

INTERIORS

E-mail: info@yezziassociates.com

Tel: 732-240-3433 Fax: 732-240-3463

Toms River, N.J. 08754

Website: www.yezziassociates.com

ENGINEERING

18 Washington Street P.O. Box 1638

ARCHITECTURE

PLANNING

MANAGEMENT

O W

NE

R S

HI

P

O F

DO

CU

M

EN

TS

: T his d oc um en t, id ea s an d de si gn s inc or po ra te d he re in, a re in st ru me nt s of p ro fe ss ion al se rv ice a nd a re t he p ro pe rt y of

Y ez zi As so cia te s an d ar e no t to b e us ed , c op ie d or r ep ro du ce d in wh ole o r in pa rt w ith ou t ap pr ov al of

Y ez zi As so cia te s.

T he se d oc um en ts h av e be en r ev ie we d wi th t he c lie nt p rio r to b ei ng s ign ed a nd s ea le d by Y ez zi

As so cia te s to in su re c on fo rm an ce w ith c lie nt s sc op e of w or k.

Pr oj ec t

Project Bid Date

Revisions By Date

Seal

-NJArchitect No. C 7475 Planner No. 2368 Architect No. 019392 Architect No. 012739B Architect No. 7460 Architect No. 8475 Architect No. 5975 Architect No. 92394 Architect No. 5733 Architect No. 9787-005 Architect No. 39914 Architect No. 30262377

-NJ

-NY

-PA

-CT

-NC

-SC

-FL

-NV

-WISC

-NCARB

-AIA

Architect No. AI01544800 Architect No. 023995

-NJ

-NY

Massimo Francis Yezzi, Jr.

Philip J. Reina

Signature Not Valid Without Raised Seal Signature Date

Do Not Scale Drawings - Field check all dimensions prior to start of construction.

BU

IL

DI

NG

S

G R O

UN

DS

W

AR

EH

O

US

E #6

E

XT

ER

IO

R R

EN

O V

AT

IO

NS

FO

R O

CE

AN

C O

UN

TY

CH

ES

TN

UT

S

TR

EE

T O

CE

AN

C

O

UN

TY

TO

M S

R

IV

ER

NE

W J

ER

S

EY

YEZZI INTERIORS

Tel: 732-240-3432

Sara Reidmiller Int. Designer No. ID0050100 -NJ

-NCIDQInt. Designer No. 37166

Samantha Karaczun Int. Designer No. ID0052100 -NJ

-NCIDQInt. Designer No. 240207

BG2026-007

A-2.0

SCALE:

EAST ELEVATION

A-2.0

3/32" = 1'-0"SCALE:

WEST ELEVATION

A-2.0

3/32" = 1'-0"

SCALE:

SOUTH ELEVATION

A-2.0

3/32" = 1'-0"

SCALE:

NORTH ELEVATION

A-2.0

3/32" = 1'-0"

A-2.0

A-2.0

A-2.0

A-2.0

A-2.0

8 9 10 11 12 13 14

65432

NEW ROOF SYSTEM APPLIED TO

EXISTING ROOF SYSTEM (TYP.)

NEW ROOF SYSTEM APPLIED TO

EXISTING ROOF SYSTEM (TYP.)

NEW ROOF SYSTEM APPLIED TO

EXISTING ROOF SYSTEM (TYP.)

NEW ROOF SYSTEM APPLIED TO

EXISTING ROOF SYSTEM (TYP.)

ALT. #3 EXISTING

OVERHEAD/COILING DOORS TO

REMAIN, CLEAN, SAND, PREP AND

RE-PAINT. TYP. AT ALL

OVERHEAD/COILING DOORS (COLOR

AS SELECTED BY OWNER)

ALT. #3 EXISTING

OVERHEAD/COILING DOORS TO

REMAIN, CLEAN, SAND, PREP AND

RE-PAINT. TYP. AT ALL

OVERHEAD/COILING DOORS (COLOR

AS SELECTED BY OWNER)

ALT. #3 EXISTING

OVERHEAD/COILING DOORS TO

REMAIN, CLEAN, SAND, PREP AND

RE-PAINT. TYP. AT ALL

OVERHEAD/COILING DOORS (COLOR

AS SELECTED BY OWNER)

NEW METAL WALL

PANEL (TYP.) (REFER

TO DETAIL)

NOTES:

REPLACE EXISTING GUTTER AND DOWNSPOUTS, SIZES TO

MATCH EXISTING. COLOR AS SELECTED BY OWNER. EXISTING

DOWNSPOUT BOOT TO REMAIN, TIE NEW DOWNSPOUT INTO

EXISTING SYSTEM. (TYP.)

CONTRACTOR TO FIELD VERIFY IRRIGATION SYSTEM SPRINKLER

HEADS AND UNDERGROUND PIPING WITH OWNER PRIOR TO

WORK.

ALT. #1 - REPLACE ALL 'MAN' DOORS WITH NEW. REFER TO

FLOOR PLAN AND DOOR SCHEDULE FOR ADDITIONAL

INFORMATION.

ALT. #2 - REMOVE AND REPLACE ALL WINDOWS (19).

REPAIR/REPLACE ANY ROTTED SILL, ETC. MATCH EXISTING

CONDITIONS

ALT. #3 - POWER WASH AND REPAINT EXISTING BUILDING AND

COILING DOORS.

1.

2.

EXISTING GAS METER

AND PIPING TO REMAIN

EXISTING HVAC UNITS,

DISCONNECTS, LINE

SETS, ETC. TO REMAIN

EXISTING CONDUIT

TO REMAIN

EXISTING UTILITY

POLE TO REMAIN

PROVIDE AND INSTALL NEW ROOF LEADER

AT LOCATIONS WHERE MISSING (3)

NEW SPLASH BLOCK,

TYP. OF 4

NEW SPLASH

BLOCK, TYP. OF 4

EXISTING CONDUIT AND

BUS DUCT TO REMAIN

EXISTING HOSE BIBB TO REMAIN

EXISTING DISCONNECT

TO REMAIN

EXISTING LINE SET

TO REMAIN

PROVIDE AND INSTALL NEW

ROOF LEADER AT LOCATIONS

WHERE MISSING (3)

14'-0" PANELS

ALIGN W/ WINDOW

ALT. #3 EXISTING METAL WALL PANELS

TO REMAIN, POWER WASH AND PAINT

(PRIMED AND PAINTED 2 COATS) (TYP.)

ALT. #3 EXISTING METAL WALL PANELS

TO REMAIN, POWER WASH AND PAINT

(PRIMED AND PAINTED 2 COATS) (TYP.)

ALT. #3 EXISTING METAL WALL PANELS

TO REMAIN, POWER WASH AND PAINT

(PRIMED AND PAINTED 2 COATS) (TYP.)

ALT. #3 EXISTING METAL WALL PANELS

TO REMAIN, POWER WASH AND PAINT

(PRIMED AND PAINTED 2 COATS) (TYP.)

NEW METAL WALL PANEL

(REFER TO DETAIL) (TYP.)

ALT. #3 EXISTING METAL WALL PANELS

TO REMAIN, POWER WASH AND PAINT

(PRIMED AND PAINTED 2 COATS) (TYP.)

ALT. #2 REMOVE EXISTING WINDOWS AND

FRAMES AND REPLACED WITH NEW -SEE FLOOR

PLANS FOR ADDITIONAL INFORMATION (TYP. ALL

WINDOWS)

ALT. #2 REMOVE EXISTING WINDOWS AND

FRAMES AND REPLACED WITH NEW -SEE FLOOR

PLANS FOR ADDITIONAL INFORMATION (TYP. ALL

WINDOWS)

ALT. #2 REMOVE EXISTING WINDOWS AND

FRAMES AND REPLACED WITH NEW -SEE FLOOR

PLANS FOR ADDITIONAL INFORMATION (TYP.)

ALT. #1 REMOVE EXISTING DOOR AND FRAME

AND REPLACED WITH NEW -SEE FLOOR

PLANS FOR ADDITIONAL INFORMATION (TYP.

ALL DOORS)

ALT. #1 REMOVE EXISTING DOOR AND FRAME

AND REPLACED WITH NEW -SEE FLOOR

PLANS FOR ADDITIONAL INFORMATION (TYP.

ALL DOORS)

FIELD CUT EXISTING PANELS 3'-0" ABOVE

CONC. APRON/FINISH FLOOR

NEW CONTINUOUS UPPER DRIP FLASHING

INSTALLED BEHIND EXISTING WALL PANELS.

FIELD CUT CORRUGATED PANEL BELOW

EXISTING FASTENERS (TYP.)

8" HORIZONTAL FURRING CHANNEL @ 18"

O.C. MAX., INSTALL OVER NEW VERTICAL

METAL STUDS

BOTTOM DRIP FLASHING, SECURE TO

8" FURRING CHANNEL

NEW WALL PANEL - "R" PANEL AS MANUF.

BY "IMETCO" OR ARCHITECT APPROVED

EQUAL. MATCH EXISTING. (TYP.)

O .C

M

AX

TY

P.

3' -0

FINISHED FLOOR

EXISTING EXTERIOR CONC. WALK TO

REMAIN (TYP.)

3 58" R-13 FOIL FACED INSULATION (TYP.)

3 58" 18 GA. METAL STUDS @ 16" O.C.

3 58" 18 GA. METAL

TRACK (TYP.)

3 58" 18 GA. METAL

TRACK (TYP.)

EXISTING HORIZ.

WALL STRUCTURE

TO REMAIN (TYP.)

SCALE:

WALL RESTORATION SECTION

A-2.0

1 1/2" = 1'-0"

NEW SOFFIT PANEL

DETAIL A

NEW .040 METAL

PANEL #311 AS

MANUF/ BY "IMETCO"

OR ARCHITECT

APPROVED EQUAL.

FLASHING

NEW ANGLE TRIM

RIVETED TO PANEL

NEW SUPPORT ZEE

A

A

NEW ZIP RIB PANEL BY IMETCO OR

ARCHITECT APPROVED EQUAL (TYP.)

NEW .050 ALUMINUM

GUTTERS AND .050 LEADERS

BY IMETCO OR ARCHITECT

APPROVED EQUAL (TYP.)

BEAM FLASHING W/ ALUM

END CAP - BOX IN W/ METAL

PANEL #311 AS MANUF/ BY

"IMETCO" OR ARCHITECT

APPROVED EQUAL.

SOFFIT PANEL ATTACHED TO

EXISTING C-CHANNELS AND NEW

FASTENING ANGLE @ WALL

.063 BEAM COVER

FLASHING BEYOND.

DETAIL B

NEW EAVE FASCIA

B

B

NOTE: CONTRACTOR TO VERIFY

ALL EXISTING CONDITIONS PRIOR

TO STARTING ANY WORK (TYP.)

EXISTING ROOF PANELS (TYP.)

6 14"

1'-

3"

A-2.1

A-2.1 SIM.

G.C. TO PROIVDE & INSTALL NEW SNOW

GUARDS AS MANUF BY "IMETCO" OR

ARCHITECT APPROVED EQUAL.

SCALE:

TYPICAL SOFFIT DETAILS

A-2.0

1 1/2" = 1'-0"

EXTERIOR ELEVATIONS &

DETAILS

7SK

MFY

A-2.0

JULY 28, 2026

YC25108

Drawn By

Chk'd By

Sheet No.

Project No.

OF

Sheet Title

YEZZI ASSOCIATES

INTERIORS

E-mail: info@yezziassociates.com

Tel: 732-240-3433 Fax: 732-240-3463

Toms River, N.J. 08754

Website: www.yezziassociates.com

ENGINEERING

18 Washington Street P.O. Box 1638

ARCHITECTURE

PLANNING

MANAGEMENT

O W

NE

R S

HI

P

O F

DO

CU

M

EN

TS

: T his d oc um en t, id ea s an d de si gn s inc or po ra te d he re in, a re in st ru me nt s of p ro fe ss ion al se rv ice a nd a re t he p ro pe rt y of

Y ez zi As so cia te s an d ar e no t to b e us ed , c op ie d or r ep ro du ce d in wh ole o r in pa rt w ith ou t ap pr ov al of

Y ez zi As so cia te s.

T he se d oc um en ts h av e be en r ev ie we d wi th t he c lie nt p rio r to b ei ng s ign ed a nd s ea le d by Y ez zi

As so cia te s to in su re c on fo rm an ce w ith c lie nt s sc op e of w or k.

Pr oj ec t

Project Bid Date

Revisions By Date

Seal

-NJArchitect No. C 7475 Planner No. 2368 Architect No. 019392 Architect No. 012739B Architect No. 7460 Architect No. 8475 Architect No. 5975 Architect No. 92394 Architect No. 5733 Architect No. 9787-005 Architect No. 39914 Architect No. 30262377

-NJ

-NY

-PA

-CT

-NC

-SC

-FL

-NV

-WISC

-NCARB

-AIA

Architect No. AI01544800 Architect No. 023995

-NJ

-NY

Massimo Francis Yezzi, Jr.

Philip J. Reina

Signature Not Valid Without Raised Seal Signature Date

Do Not Scale Drawings - Field check all dimensions prior to start of construction.

BU

IL

DI

NG

S

G R O

UN

DS

W

AR

EH

O

US

E #6

E

XT

ER

IO

R R

EN

O V

AT

IO

NS

FO

R O

CE

AN

C O

UN

TY

CH

ES

TN

UT

S

TR

EE

T O

CE

AN

C

O

UN

TY

TO

M S

R

IV

ER

NE

W J

ER

S

EY

YEZZI INTERIORS

Tel: 732-240-3432

Sara Reidmiller Int. Designer No. ID0050100 -NJ

-NCIDQInt. Designer No. 37166

Samantha Karaczun Int. Designer No. ID0052100 -NJ

-NCIDQInt. Designer No. 240207

BG2026-007

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

8/A

NOTE: THIS DETAIL IS ONLY SUITABLE FOR PENETRATIONS THAT ALLOW

FOR 1" MIN. CLEARANCE FROM OUTSIDE OF BOOT BASE TO PANEL RIB.

THE INSTALLER MUST COORDINATE WITH GC AND OTHER TRADES.

1" MIN

TYP.

FOR EXTREME TEMPERATURE APPLICATIONS REFER TO MANUFACTURER SPECIFICATIONS

STAINLESS STEEL DRAW

BAND (TYP.)

METAL STORM COLLAR FINISH TO

MATCH ROOF (TYP.)

RUBBER BOOT (DEKTITE BY ITW

BUILDEX OR APPROVED EQUAL)

CUT TO SUIT PIPE PENETRATION

(TYP.)

RIVET BOOT TO PANEL (F7) @ 3"

o/c WITH CONT. BEAD OF

SEALANT (S1) BETWEEN BOOT &

PANEL (TYP.)

NOTE:

WHEN THE PIPE IS FIXED TO THE

STRUCTURE AND NOT DESIGNED

TO FLOAT WITH ROOF PANELS.

CUT HOLE IN PANEL TO ALLOW

FOR THE MAX. ANTICIPATED

THERMAL EXPANSION. (USUALLY

1" WIDER THAN PIPE)

EXTEND EXISTING PIPE AS

REQUIRED TO MEET CODE

(TYP.)

5.5" TALL IRF ZEE

5.5" TALL IRF ZEE

2.25"

3.25"

IRF

5.5" TALL IRF ZEE

3.25" TALL IRF HAT

IRF ZEE

2.25" TALL IRF HAT

2'- 0"

2'- 0"

2'- 0"

2'- 0"

NOTE:

ALL ZONES SIMILAR, G.C.

TO SUBMIT SHOP

DRAWINGS FOR REVIEW.

NOTES:

1. ALL FASTENERS TO BE PROVIDED BY G.C.

2. FOR EXISTING TRAPEZOIDAL SSR WITH STAND-OFF CLIP AND THERMAL SPACER, REFER TO

DETAIL SHEET HA-10-TSO

3. ALL NEW ROOF SYSTEMS, INCLUIDNG PANEL, FASTENER, TRIM, AND ACCESSORIES, TO BE

INSTALLED PER THE MANUFACTUER'S STANDARDS.

5.5" TALL IRF ZEE

5/A (SECOND ONE)

ROOF DETAILS

8SK

MFY

A-2.1

JULY 28, 2026

YC25108

Drawn By

Chk'd By

Sheet No.

Project No.

OF

Sheet Title

YEZZI ASSOCIATES

INTERIORS

E-mail: info@yezziassociates.com

Tel: 732-240-3433 Fax: 732-240-3463

Toms River, N.J. 08754

Website: www.yezziassociates.com

ENGINEERING

18 Washington Street P.O. Box 1638

ARCHITECTURE

PLANNING

MANAGEMENT

O W

NE

R S

HI

P

O F

DO

CU

M

EN

TS

: T his d oc um en t, id ea s an d de si gn s inc or po ra te d he re in, a re in st ru me nt s of p ro fe ss ion al se rv ice a nd a re t he p ro pe rt y of

Y ez zi As so cia te s an d ar e no t to b e us ed , c op ie d or r ep ro du ce d in wh ole o r in pa rt w ith ou t ap pr ov al of

Y ez zi As so cia te s.

T he se d oc um en ts h av e be en r ev ie we d wi th t he c lie nt p rio r to b ei ng s ign ed a nd s ea le d by Y ez zi

As so cia te s to in su re c on fo rm an ce w ith c lie nt s sc op e of w or k.

Pr oj ec t

Project Bid Date

Revisions By Date

Seal

-NJArchitect No. C 7475 Planner No. 2368 Architect No. 019392 Architect No. 012739B Architect No. 7460 Architect No. 8475 Architect No. 5975 Architect No. 92394 Architect No. 5733 Architect No. 9787-005 Architect No. 39914 Architect No. 30262377

-NJ

-NY

-PA

-CT

-NC

-SC

-FL

-NV

-WISC

-NCARB

-AIA

Architect No. AI01544800 Architect No. 023995

-NJ

-NY

Massimo Francis Yezzi, Jr.

Philip J. Reina

Signature Not Valid Without Raised Seal Signature Date

Do Not Scale Drawings - Field check all dimensions prior to start of construction.

BU

IL

DI

NG

S

G R O

UN

DS

W

AR

EH

O

US

E #6

E

XT

ER

IO

R R

EN

O V

AT

IO

NS

FO

R O

CE

AN

C O

UN

TY

CH

ES

TN

UT

S

TR

EE

T O

CE

AN

C

O

UN

TY

TO

M S

R

IV

ER

NE

W J

ER

S

EY

YEZZI INTERIORS

Tel: 732-240-3432

Sara Reidmiller Int. Designer No. ID0050100 -NJ

-NCIDQInt. Designer No. 37166

Samantha Karaczun Int. Designer No. ID0052100 -NJ

-NCIDQInt. Designer No. 240207

BG2026-007

SCALE:

TYP. RIDGE DETAIL

A-2.1

3"=1'-0"

SCALE:

HAT GRID INTELLIFRAME RF (IRF)

A-2.1

NOT TO SCALESCALE:

IRF ATTACHMENT TO EXISTING PURLIN

A-2.1

NOT TO SCALE

SCALE:

IRF ATTACHMENT TO EXISTING PURLIN

A-2.1

NOT TO SCALE

SCALE:

IRF LAP ATTACHMENT

A-2.1

NOT TO SCALE

NEW ROOFING AS MANUFACTURED BY

"IMETCO" OR ARCHITECT APPROVED

EQUAL WITH PREMIUM GRADE FINISHES

(TYP.)

.040 GA. ALUM. PANELS. COLOR AS

SELECTED BY OWNER (TYP.)

SUBMIT FULL SHOP DRAWINGS AND

SAMPLES FOR REVIEW AND APPROVAL

PRIOR TO CONSTRUCTION (TYP.)

SCALE:

TYP. ROOF PENETRATION DETAIL

A-2.1

3"=1'-0"

SCALE:

TYP. ROOF PENETRATION DETAIL

A-2.1

3"=1'-0"

SCALE:

WIND/SNOW LOAD CALCULATIONS

A-2.1

NOT TO SCALE

SCALE:

TYP. GUTTER DETAIL

A-2.1

3"=1'-0"

WINDOW UNIT

(HORIZONTAL SLIDE, 1"

INSULATED GLASS)

WINDOW FASTENER BY

"GLOBAL BUILDING PRODUCTS"

INSTALL AS PER MANUF.

SPECIFICATIONS (TYP.)

NEW SEALANT

CONTINUOUS AROUND

OUTSIDE OF PANEL

BASE (TYP.)

EXISTING FRAMED

OPENING JAMB (TYP.)

EXISTING FRAMED

OPENING

HEADER (TYP.)

WINDOW FASTENER BY

"GLOBAL BUILDING

PRODUCTS" INSTALL

AS PER MANUF.

SPECIFICATIONS (TYP.)

NEW SEALANT

CONTINUOUS

AROUND OUTSIDE OF

PANEL BASE (TYP.) FRAMED

OPENING SILL

PANEL CLOSURE

W/ NEW SEALANT

(TYP. EACH SIDE)

WJ-1WH-1 WS-1

EXISTING WALL TO

REMAIN - REPAIR

AS REQ'D. (TYP.)

EXISTING WALL

TO REMAIN -

REPAIR AS

REQ'D.

SCALE:

WINDOW DETAILS

A-3.0

1 1/2" = 1'-0"

REPLACE EXISTING WINDOW

UNITS IN-KIND (SLIDER UNITS

W/ 1" INSULATED GLASS) AS

MANUF. BY "GLOBAL BUILDING

PRODUCTS." SUBMIT SHOP

DRAWINGS FOR REVIEW.

G.C. TO VERIFY WINDOW SIZES.

SUBMIT SHOP DRAWINGS FOR

REVIEW PRIOR TO

INSTALLATION (TYP.)

SCALE:

EXISTING CONDITION PHOTOGRAPH

A-3.0

1/4" = 1'-0"

DOOR HARDWARE SETS

DOOR SCHEDULE

RATING LABEL

(MINUTES)

3'-0"x7'-0"x1 3/4 0

2 FRP

HARDWARE

SET

3'-0"x7'-0"x1 3/4 12"x12"x1" 0FRP

D-1 0

H-1 J-1 S-1

3'-0"x7'-0"x1 3/4 0FRP5

3'-0"x7'-0"x1 3/4 0FRP6

3'-0"x7'-0"x1 3/4 12"x12"x1" 0FRP7

3'-0"x7'-0"x1 3/4 0FRP8

3'-0"x7'-0"x1 3/4 0FRP9

3'-0"x7'-0"x1 3/4 0FRP10

3'-0"x7'-0"x1 3/4 0FRP11

3'-0"x7'-0"x1 3/4 0FRP12

3'-0"x7'-0"x1 3/4 0FRP13

3'-0"x7'-0"x1 3/4 0FRP14

FRP

FRP

3'-0"x7'-0"x1 3/4

3'-0"x7'-0"x1 3/4

24"x36"x1"

D-2

D-1

D-3

D-2

D-2

D-3

D-1

D-1

D-1

D-1

D-1

D-1

D-1

F-1

J-1 S-1 F-1

J-1 S-1 F-1

J-1 S-1 F-1

J-1 S-1 F-1

J-1 S-1 F-1

J-1 S-1 F-1

J-1 S-1 F-1

J-1 S-1 F-1

J-1 S-1 F-1

J-1 S-1 F-1

J-1 S-1 F-1

J-1 S-1 F-1

J-1 S-1 F-1

24"x36"x1"

24"x36"x1"

24"x36"x1"

24"x36"x1"

24"x36"x1"

24"x36"x1"

24"x36"x1"

24"x36"x1"

NONE

NONE

NONE

SET 01 - EXTERIOR DOOR W/ KEY ENTRY

1 CONTINUOUS HINGE

1 RIM EXIT DEVICE

1 EXIT DEVICE TRIM

1 RIM CYLINDER

1 CONSTRUCTION CORE

1 PERM CORMAX CORE

1 CLOSER

1 KICK PLATE

1 WEATHER STRIP

1 DRIP CAP

1 AUTO DOOR BOTTOM

1 SADDLE THRESHOLD

1,2,3,4,5,6

1. ALL GLAZING AT DOORS ARE TO BE 1" INSULATED SAFETY GLASS TEMPERED (1

4" SAFETY GLASS TEMPERED / 1 2" AIR SPACE / 14" SAFETY GLASS TEMPERED)

2. ALL FRP DOORS ARE TO BE BY "SPECIAL-LITE" MODEL# SUPER-TOUGH SL-17 PEBBLEGRAIN FLUSH DOOR OR ARCHITECT APPROVED EQUAL, COLOR AS SELECTED BY OWNER FROM ALL AVAILABLE COLORS, W/ ALUMINUM FRAMES AS

INDICATED ON DRAWINGS (TYP.)

3. G.C. IS TO FIELD VERIFY THE ROUGH & FINISH OPENINGS FOR ALL DOORS (TYP.)

4. G.C. MUST SUBMIT A FULL SET OF SHOP DRAWINGS FOR ALL DOORS, FRAMES, HARDWARE AND ALL RELATED ITEMS FOR REVIEW AND APPROVAL PRIOR TO ANY WORK BEING DONE (TYP.)

5. ALL INTEGRAL DOOR SWEEPS ARE TO BE BY "SPECIAL-LITE" MODEL# SL-301 OR ARCHITECT APPROVED EQUAL (TYP.)

6. REPAIR ALL DAMAGED GYP. BD., TRIM, ETC. EFFECTED BY DOOR AND FRAME REPLACEMENT, PRIME AND PAINT TO MATCH SURROUNDING CONDITIONS (TYP.)

7. EXISTING PUSH BUTTON LOCK TO BE REMOVED AND REINSTALLED ON NEW DOOR - ALL OTHER HARDWARE AS PER HARDWARE SCHEDULE BELOW (TYP.)

1. ALL HARDWARE MUST BE ADA COMPLIANT (TYP.)

2. ALL EXISTING REMAINING HARDWARE IS TO BE CLEANED & SERVICED BY THE G.C. AS PART OF THEIR BASE BID (TYP.)

3. THE COUNTY STANDARD FOR CORES IS "BEST" 7 PIN "CORMAX" AND KEYS. ALL NEW HARDWARE MUST BE ABLE TO INTERFACE WITH THE OCEAN COUNTY STANDARD HARDWARE REQUIREMENTS. REFER TO DOOR HARDWARE

SPECIFICATIONS FOR ADDITIONAL INFORMATION AND REQUIREMENTS.

4. EXISTING PUSH BUTTON LOCK AT DOOR 10 TO BE REMOVED AND REINSTALLED ON NEW DOOR - ALL OTHER HARDWARE AS PER HARDWARE SCHEDULE (TYP.)

DOOR HARDWARE SET NOTES

DOOR NOTES

1,2,3,4,5,6

1,2,3,4,5,6

1,2,3,4,5,6

2,3,4,5,6

2,3,4,5,6

1,2,3,4,5,6

1,2,3,4,5,6

1,2,3,4,5,6

1,2,3,4,5,6,7

1,2,3,4,5,6

1,2,3,4,5,6

1,2,3,4,5,6

1,2,3,4,5,6

SET 02 - EXTERIOR DOOR W/ KEYPAD

1 CONTINUOUS HINGE

1 RIM EXIT DEVICE

1 NEXTOUCH EXIT TRIM

1 MORTISE CYLINDER

1 CONSTRUCTION CORE

1 PERM CORMAX CORE

1 CLOSER

1 KICK PLATE

1 WEATHERSTRIP

1 DRIP CAP

1 AUTO DOOR BOTTOM

1 SADDLE THRESHOLD

H-1

H-1

H-1

H-1

H-1

H-1

H-1

H-1

H-1

H-1

H-1

H-1

H-1

MAT'LTYPENO. DOOR SIZE GLASS NOTESSILLJMB.HD. FRAME

F-1

ALUMINUM DOOR

FRAME

3'-0"2" 2"

2" 7'

-0

SCALE:

FRAME TYPES

A-3.0

1/4" = 1'-0"

D-1

FRP DOOR

24"x36"

1" INSULATED

GLASS

SEE

SCHEDULE

S

EE

S

CH

ED

UL

E

D-2 D-3

FRP DOOR

SEE

SCHEDULE

S

EE

S

CH

ED

UL

E

FRP DOOR

SEE

SCHEDULE

S

EE

S

CH

ED

UL

E

12"x12"

1" INSULATED

GLASS

SCALE:

DOOR TYPES

A-3.0

1/4" = 1'-0"

1 2"

13 4

NEW FRP DOOR

NEW SEALANT AT JOINT (TYP).

J-1

EXISTING SHORT CLIP

TO REMAIN (TYP.)

EXISTING SUB-JAMB - TO

REMAIN, REPAIR AS REQ'D.

EXISTING GIRT TO REMAIN (TYP.)

2 1 4" 2"

NEW ALUMINUM FRAME

2"

134"

S-1

1/ 2"

M

AX

NEW FRP DOOR

NEW 1/2" SEALANT,

BACKER ROD &

PREFORMED

EXPANSION JT.

NEW ADA

COMPLIANT

SADDLE

EXTERIOR

CONC.

EDGE OF NEW

DOOR JAMB

BEYOND

EXISTING METAL PANEL

TO REMAIN (TYP.)

EXISTING FLASHING

TO REMAIN - REPAIR

AS REQUIRED BY NEW

DOOR FRAME

INSTALLATION (TYP.)

EXISTING GIRT TO REMAIN

(TYP.)

NEW ALUMINUM

FRAME

NEW SEALANT AT

JOINT (TYP).

NEW FRP

DOOR

NEW SEALANT AT

JOINT (TYP).

NEW WOOD SHIM AS

REQ'D (TYP).

H-1

SCALE:

DOOR DETAILS

A-3.0

1 1/2" = 1'-0"

BID ALTERNATE #1

BID ALTERNATE #2

BID ALTERNATE #3

1. EXTERIOR PAINT AND COATING SYSTEMS

A. METAL: STEEL PANEL PREVIOUSLY PAINTED BAKED ENAMEL FINISH

1. WATERBASED ACRYLIC SYSTEMS:

a. SEMI-GLOSS FINISH:

1) SPOT PRIME AS NEEDED: S-W PRO INDUSTRIAL PRO-CRYL UNIVERSAL PRIMER, B66-1310 SERIES (5.0-10.0 MILS. WET, 1.8-3.6 MILS. DRY PER COAT).

2) 2ND COAT: S-W BOND-PLEX WATERBASED ACRYLIC COATING B71W00211

3) 3RD COAT: S-W BOND-PLEX WATERBASED ACRYLIC COATING B71W00211 (5.0-10 MILS.WET, 2.4- 4.1 DRY PER COAT).

NOTE: RUSTED AREAS SSPC SP-2 HAND TOOL AND SSPC SP-3 POWER TOOL

ALTERNATE #3 PAINT

METAL WALL PANELS

OVERHEAD DOORS

A. METAL: STEEL OVERHEAD DOORS AND DOORS AND FRAMES

1. WATER BASED ALKYD SYSTEMS:

a. SEMI-GLOSS FINISH:

1) 1ST COAT: S-W PRO INDUSTRIAL PRO-CRYL UNIVERSAL PRIMER, B66-1310 SERIES (5.0 MILS. WET, 2.0 MILS. DRY PER COAT)

2) 2ND COAT: S-W PRO INDUSTRIAL WATERBASED ALKYD URETHANE ENAMEL SEMI-GLOSS B53-1150 SERIES

3RD COAT: S-W PRO INDUSTRIAL WATERBASED ALKYD URETHANE ENAMEL SEMI-GLOSS B53-1150 SERIES (4.0-5.0 MILS. WET, 1.4-1.7 MILS. DRY PER COAT)

ALTERNATE DETAILS

DOORS & WINDOWS

9SK

MFY

A-3.0

JULY 28, 2026

YC25108

Drawn By

Chk'd By

Sheet No.

Project No.

OF

Sheet Title

YEZZI ASSOCIATES

INTERIORS

E-mail: info@yezziassociates.com

Tel: 732-240-3433 Fax: 732-240-3463

Toms River, N.J. 08754

Website:…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .