Bella House Kitchen and Bathroom Rehab - Construction Plans Summary

This is a 100% construction document set prepared by COAR Design Group for Napa County's Bella House facility located at 1046 Bella Drive, Napa, California. The project scope encompasses a tenant improvement rehabilitation of an existing licensed social rehabilitation facility that provides mental health residential services for up to 12 adults. The rehabilitation work includes complete demolition and replacement of kitchen and bathroom equipment, fixtures, casework, and flooring finishes; installation of new plumbing, electrical, and mechanical systems; interior painting; and LED light bulb replacement throughout the facility. The design package includes architectural, mechanical, plumbing, and electrical drawings prepared under 2025 California Building Code standards, with construction documents completed as of August 11, 2026. The project is classified as RS-10 construction type with occupancy group V-B, sprinklered, and includes three bathrooms (identified as Blue, White, and Red Restroom) and one kitchen requiring rehabilitation. A critical sequencing constraint requires that only one restroom be taken out of service at any given time during construction, as the facility will remain occupied and operational with residents throughout the project duration. Contractor must coordinate all work activities with facility and County staff to minimize disruption to residents and must not commence work prior to the notice to proceed date specified in the project's Special Provisions and General Conditions.

The construction documents detail comprehensive specifications for materials, finishes, fixtures, and equipment including luxury vinyl tile flooring, gypsum board walls finished in PPG paint, plastic laminate casework with solid surface countertops and backsplashes, and bathroom fixtures with grab bars and accessibility features. The design incorporates fire safety requirements including fire-extinguishing system specifications, fire alarm systems, sprinkler flow alarms, and egress illumination standards. Mechanical work involves HVAC systems and exhaust fans; plumbing work includes sink installations, faucets, toilets, bathtubs, and shower systems; and electrical work comprises LED lighting fixture installations, receptacle placement, and circuit upgrades including two new 20-amp single-pole branch breakers. The project team includes Lefler Engineering Inc. (Civil/Mechanical), COAR Design Group (Architecture), O'Mahony & Myer (Plumbing/Electrical), and Napa County as the owner with Roberto De La Torre Real as the County contact. All work must comply with Napa County requirements and California Building Standards Code Title 24, with construction observation and compliance affidavits required from a registered California architect or engineer.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SITE

1046 BELLA DRIVE

NAPA, CA 94558

036-213-002-000

COUNTY OF NAPA

1195 THIRD STREET, #210

NAPA, CA 94559

2025 CALIFORNIA BUILDING CODE

2025 CALIFORNIA FIRE CODE

2025 CALIFORNIA ENERGY CODE

2025 CALIFORNIA GREEN BUILDING STANDARDS

2025 CALIFORNIA ELECTRICAL CODE

2025 CALIFORNIA MECHANICAL CODE

2025 CALIFORNIA PLUMBING CODE

2025 CALIFORNIA EXISTING BUILDING CODE

RS 10

V-B

YES

OCCUPANCY GROUP(S)

PROJECT ADDRESS:

ASSESSOR'S PARCEL NUMBER:

GOVERNING AGENCY:

GOVERNING CODES:

ZONING:

CONSTRUCTION TYPE:

SPRINKLERED:

OCCUPANCIES:

LEFLER ENGINEERING INC.

1651 SECOND STREET

SAN RAFAEL, CA 94901

(415) 456-4220 Contact: TREVOR LEFLER

TREVOR@LEFLERENGINEERING.COM

ARCHITECTURE

COAR Design Group

Contact: JEFF KATZ, AIA

JEFF@COARGROUP.COM

PLUMBING ELECTRICAL

O'MAHONY & MYER

4340 REDWOOD HIGHWAY #245

SAN RAFAEL, CA 94903

(415) 492-0420 Contact: PIETER COLENBRANDER, PE, LEED AP

PCOLENBRANDER@OMMCONSULTING.COM

OWNER

COUNTY OF NAPA

1195 THIRD STREET, SUITE 101

NAPA, CA 94559

(707) 253-4417 Contact: ROBERTO DE LA TORRE REAL

ROBERTO.DELATORREREAL@COUNTYOFNAPA.ORG

MECHANICAL

200 E STREET

SANTA ROSA, CA 95404

(707) 544-3920

LEFLER ENGINEERING INC.

1651 SECOND STREET

SAN RAFAEL, CA 94901

(415) 456-4220 Contact: TREVOR LEFLER

TREVOR@LEFLERENGINEERING.COM

SCOPE OF WORK: TENANT IMPROVEMENT OF AN EXISTING FACILITY. UPDATING INTERIOR

FINISHES OF RESTROOMS AND KITCHEN.

SITE

A REGISTERED CALIFORNIA ARCHITECT, CIVIL OR STRUCTURAL ENGINEER SHALL OBSERVE

THE WORK OF CONSTRUCTION AND SUBMIT AFFIDAVITS ATTESTING TO THE COMPLIANCE OF

THE CONSTRUCTION WITH THE APPROVED CONTRACT DOCUMENTS.

NOTE:

PROJECT NUMBER:

SHEET TITLE:

NOT FOR

CONSTRUCTION

PROJECT:

SHEET NUMBER:

200 E STREET, SANTA ROSA, CA 95404

707.544.3920 | www.coargroup.com

DESCRIPTION: DATE:

100% SCHEMATIC

DESIGN

6/10/26

90% CDs 7/7/26

100%

CONSTRUCTION

DOCUMENTS

8/11/26

TITLE SHEET

260501

T-1

BELLA HOUSE KITCHEN

AND BATHROOM REHAB

NAPA COUNTY

1046 BELLA DR, NAPA, CA,

94558

BELLA HOUSE KITCHEN AND BATHROOM REHAB

1046 BELLA DR, NAPA, CA, 94558

LOCATION MAP

PROJECT DATA PROJECT TEAMSCOPE OF WORK

VICINITY MAP

JUAN S. ARIAS COUNTY ENGINEER R.C.E. #C63365

GRID

DETAIL

BUILDING SECTION

WALL TYPE

WINDOW TYPE

DOOR NUMBER

ROOM NUMBER

DATUM POINT

CORNER GUARD

FIRE EXTINGUISHER

CONTINUOUS, UNOBSTRUCTED AND

UNDIMINISHED PATH OF TRAVEL

ROOM NAME

ROOM NUMBER

INTERIOR ELEVATION

CG

FE

BUNK

AT LEAST ONE PORTABLE FIRE EXTINGUISHER WITH A MINIMUM RATING OF 2A10BC

SHALL BE PROVIDED WITHIN 75' MAXIMUM TRAVEL DISTANCE FOR EACH 3,000

SQUARE FEET OR PORTION THEREOF ON EACH FLOOR (CFC 906, UFC STANDARD

10-1, TITLE 19, SECT. 3.29). SEE PLANS FOR LOCATIONS.

AT LEAST ONE FIRE EXTINGUISHER WITH A MINIMUM RATING OF 4A2OBC SHALL BE

PROVIDED OUTSIDE OF EACH MECHANICAL, ELECTRICAL OR BOILER ROOM. (CFC

906, UFC STANDARD 10-1, TITLE 19, SECT. 3.29). SEE PLANS FOR LOCATIONS.

COMPLETE PLANS AND SPECIFICATIONS FOR FIRE-EXTINGUISHING SYSTEMS,

INCLUDING AUTOMATIC SPRINKLERS AND WET AND DRY STANDPIPES, HALON

SYSTEMS AND OTHER SPECIAL TYPES OF AUTOMATIC FIRE-EXTINGUISHING SYSTEMS,

BASEMENT PIPE INLETS, AND OTHER FIRE-PROTECTION SYSTEMS AND

APPURTENANCES THERETO SHALL BE SUBMITTED BY THE CONTRACTOR TO FIRE AND

LIFE SAFETY FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. (CFC 901.2)

FIRE-EXTINGUISHING SYSTEMS SHALL BE INSTALLED BY THE CONTRACTOR IN

ACCORDANCE WITH CBC 903.

ALL VALVES CONTROLLING THE WATER SUPPLY FOR AUTOMATIC SPRINKLER

SYSTEMS AND WATER-FLOW SWITCHES ON ALL SPRINKLER SYSTEMS SHALL BE

ELECTRICALLY MONITORED WHERE THE NUMBER OF SPRINKLERS IS 100 OR MORE.

(CBC 904.3.1, CFC 903.4)

COMPLETE PLANS AND SPECIFICATIONS FOR FIRE ALARM SYSTEMS INCLUDING

AUTOMATIC SPRINKLERS SHALL BE SUBMITTED BY THE CONTRACTOR TO THE FIRE

MARSHAL FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. (CFC 1001.3)

INSTALLATION OF FIRE ALARM SYSTEMS SHALL BE IN ACCORDANCE WITH CFC 907.

AN APPROVED AUDIBLE SPRINKLER FLOW ALARM SHALL BE PROVIDED ON THE

EXTERIOR OF THE BUILDING IN AN APPROVED LOCATION. AN APPROVED AUDIBLE

SPRINKLER FLOW ALARM TO ALERT THE OCCUPANTS SHALL BE PROVIDED IN THE

INTERIOR OF THE BUILDING IN A NORMALLY OCCUPIED LOCATION.

ANY TIME A BUILDING IS OCCUPIED THE MEANS OF EGRESS SHALL BE ILLUMINATED

AT AN INTENSITY OF NOT LESS THEN 1 FOOT-CANDLE AT THE FLOOR LEVEL.

EGRESS ILLUMINATION REQUIRES A SOURCE OF EMERGENCY POWER WHEN THE

OCCUPANT LOAD IS 100 OR MORE.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

DIMENSIONS SHOWN ON THE FLOOR PLANS, SECTIONS AND DETAILS ARE TO FACE OF

STUDS, COLUMN GRID LINES AND FACE OF CONCRETE AND BLOCK WALLS, UNLESS

OTHERWISE NOTED OR SHOWN.

CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS BEFORE

PROCEEDING WITH CONSTRUCTION.

ALL ITEMS ARE BASE BID UNLESS OTHERWISE NOTED OR SPECIFIED.

ALL DRAIN LINES WITHIN WALLS ARE TO BE WRAPPED IN SOUND INSULATION BATTS.

EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT USE OF A KEY OR ANY

SPECIAL KNOWLEDGE.

CONTRACTOR SHALL PROVIDE ACCESS PANELS REQUIRED BY THE PLUMBING, AIR

CONDITIONING AND OTHER INSTALLERS, AS REQUIRED BY CODE. ANY ACCESS PANEL IN

A FIRE RATED WALL OR CEILING SHALL HAVE THE SAME FIRE RATING AS THE WALL OR

CEILING IN WHICH THEY OCCUR.

STRUCTURAL AND FIRE RESISTIVE INTEGRITY SHALL BE MAINTAINED AT PENETRATIONS FOR

MECHANICAL, PLUMBING, ELECTRICAL, AND COMMUNICATIONS PIPE, DUCT AND

CONDUIT AS INDICATED.

PROVIDE FIRE BLOCKING AT FLOOR, CEILING AND MID HEIGHT OF WALLS OVER 10'-0".

STUCCO, PLASTER AND GYPSUM BOARD SHALL TERMINATE WITH A "J" MOLDING WHERE

THE EDGE IS EXPOSED UNLESS NOTED OR SPECIFIED OTHERWISE.

A FLOOR OR LANDING NOT MORE THE 1/4" BELOW THE THRESHOLD IS REQUIRED AT EACH

SIDE OF AN EXIT DOOR.

BRAND OR TRADE NAME, SUBSTITUTIONS OF "EQUALS": REQUESTS FOR SUBSTITUTIONS OF

AN ITEM AS AN "EQUAL" TO ANY ITEM INDICATED OR SPECIFIED MUST BE INCLUDED AS A

PART OF THE CONTRACTOR'S BID PROPOSAL, AS SPECIFIED IN THE GENERAL CONDITIONS.

WRITTEN DIMENSIONS TAKE PRECEDENCE OVER GRAPHIC SCALE. DO NOT SCALE

DRAWINGS.

IT SHOULD BE NOTED THAT WHILE EXISTING UTILITY DRAWINGS ARE AVAILABLE, THERE IS

NO ASSURANCE THAT ALL UTILITIES ARE SHOWN. THE CONTRACTOR SHALL PROCEED WITH

CAUTION TO INSURE THAT ALL UTILITIES ENCOUNTERED, WHETHER OR NOT OF RECORD,

SHALL BE PROTECTED FROM DAMAGE. THE CONTRACTOR SHALL ALSO TAKE

PRECAUTIONS NECESSARY TO PROTECT HIMSELF AND ALL EMPLOYEES FROM INJURY

WHICH MAY BE CAUSED BY CONTACT WITH UTILITY SERVICES.

GYPSUM BOARD FOR FIRE RATED ASSEMBLIES SHALL BE INSTALLED IN ACCORDANCE

WITH CBC CHAPTER 7.

DOOR HARDWARE SHALL BE LEVER TYPE.

MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR

DOORS AND 5 POUNDS FOR INTERIOR DOORS.

FIRE DAMPER ASSEMBLIES, INCLUDING SLEEVES AND INSTALLATION PROCEDURES SHALL

BE APPROVED BY THE BUILDING INSPECTOR PRIOR TO INSTALLATION.

INTERIOR FINISHES SHALL COMPLY WITH THE PROVISIONS OF CBC CHAPTER 8.

ALL DECORATIVE MATERIALS SHALL BE MAINTAINED IN A FLAME-RETARDANT CONDITION.

BUILDING NUMBERS SHALL BE EASILY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD

FRONTING THE PROPERTY.

THE CONSTRUCTION, REMODEL, OR DEMOLITION OF A BUILDING SHALL COMPLY WITH

THE REQUIREMENTS OF THE REQUIREMENTS OF NAPA COUNTY.

THESE PLANS AND ALL WORK SHALL COMPLY WITH THE CALIFORNIA BUILDING

STANDARDS CODE FOUND IN THE STATE OF CALIFORNIA TITLE 24 CCR, AS AMENDED AND

ADOPTED BY NAPA COUNTY.

CONTRACTOR SHALL THOROUGHLY COORDINATE ALL TRADES AS REQUIRED TO

COMPLETE ALL WORK INDICATED AND NECESSARY FOR THE PROJECT.

CONTRACTOR SHALL PROTECT EXISTING SITE FEATURES AND SHALL REPAIR OR REPLACE

ALL ITEMS DAMAGED DURING CONSTRUCTION.

THE CONTRACTOR SHALL ENFORCE ALL SAFETY MEASURES. THE CONTRACTOR SHALL

DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING AND

SHALL BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL

SAFETY AND HEALTH STANDARDS, LAWS AND REGULATION.

CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE

CONDITIONS DURING THE COURSE OF CONSTRUCTION, INCLUDING SAFETY OF ALL

PERSONS AND PROPERTY. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE

LIMITED TO NORMAL WORKING HOURS.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY MONUMENTATION AND / OR

BENCHMARKS WHICH WILL BE DISTURBED OR DESTROYED BY CONSTRUCTION. SUCH

POINTS SHALL BE REFERENCED AND REPLACED WITH APPROPRIATE MONUMENTATION BY

A LICENSED LAND SURVEY OR REGISTERED CIVIL ENGINEER AS REQUIRED BY THE LAND

SURVEYOR'S ACT.

CONTRACTOR SHALL REPLACE IN KIND ANY TRAFFIC SENSORS DAMAGED DURING

CONSTRUCTION.

PENETRATION OF FIRE RESISTIVE WALLS, FLOOR - CEILING ASSEMBLIES AND ROOF -

CEILINGS SHALL BE PROTECTED AS REQUIRED IN CBC SECTION 714.

NO HAZARDOUS MATERIALS WILL BE USED OR STORED WITHIN THE BUILDING WHICH

EXCEED THE QUANTITIES SHOWN ON CBC TABLE 307.1(1).

WHEN SERVING MORE THAN 100 SPRINKLER HEADS, AUTOMATIC SPRINKLER SYSTEMS

SHALL BE SUPERVISED BY AN APPROVED CENTRAL PROGRAM OR REMOTE STATION

SERVICE OR SHALL BE PROVIDED WITH A LOCAL ALARM WHICH WILL GIVE AN AUDIBLE

SIGNAL AT A CONSTANTLY ATTENDED LOCATION.

WORK NOT SPECIFICALLY INDICATED OR SPECIFIED BUT WHICH IS REQUIRED FOR THE

COMPLETION OF THE WORK SHALL BE PROVIDED IN THE SAME MANNER AS SIMILAR

WORK WHICH IS REQUIRED OR SPECIFIED WITHOUT ADDITIONAL CHARGE.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

23.

24.

25.

26.

27.

28.

29.

30.

31.

32.

PROJECT NUMBER:

SHEET TITLE:

NOT FOR

CONSTRUCTION

PROJECT:

SHEET NUMBER:

200 E STREET, SANTA ROSA, CA 95404

707.544.3920 | www.coargroup.com

DESCRIPTION: DATE:

100% SCHEMATIC

DESIGN

6/10/26

90% CDs 7/7/26

100%

CONSTRUCTION

DOCUMENTS

8/11/26

TITLE SHEET

260501

T-2

BELLA HOUSE KITCHEN

AND BATHROOM REHAB

NAPA COUNTY

1046 BELLA DR, NAPA, CA,

94558

T-1 TITLE SHEET

T-2 TITLE SHEET

A2.1 FIRST FLOOR PLAN & RCP

A5.1 INTERIOR ELEVATIONS

A6.1 ROOM FINISH SCHEDULE

A7.1 CABINET DETAILS

M101 MECHANICAL FIRST FLOOR PLANS

M601 MECHANICAL SCHEDULES, DETAILS AND LEGEND

P101 PLUMBING FIRST FLOOR PLANS

P601 PLUMBING SCHEDULES, DETAILS AND LEGEND

E2.1 FIRST FLOOR PLAN - LIGHTING

E3.1 FIRST FLOOR PLAN - ELECTRICAL

SYMBOLS

ABBREVIATIONS SHEET INDEX

# POUND or NUMBER

& AND

@ AT

L ANGLE

Ø DIAMETER or ROUND

ACOUS ACOUSTICAL

ACT ACOUSTICAL CEILING TILE

AD ACESS DOOR and FRAME

ALUM ALUMINUM

APP APPROXIMATE

ARCH ARCHITECTURAL

AS ACOUSTICAL SEALANT

ASB ACOUSTICAL SUSPENDED BAFFLES

B BRICK

BLDG BUILDING

BLK BLOCK

BLKG BLOCKING

BM BEAM

CC COLUMN COVER

CFB CEMENT FIBER BOARD SIDING

CJ CONTROL JOINT

CLG CEILING

CLR CLEAR

CMU CONCRETE MASONRY UNIT

CNC CONCRETE

CONT CONTINUOUS

CP CEMENT PLASTER

CPT CARPET

CW CURTAIN WALL

CWP COMPOSITE METAL WALL PANEL

DBL DOUBLE

DEFS DIRECT-APPLIED EXTERIOR FINISH SYSTEM

DET DETAIL

DIA DIAMETER

DIM or

DIMS

DIMENSION or DIMENSIONS

DN DOWN

DWG DRAWING

DWR DRAWER

(E) EXISTING

EA EACH

EIFS EXTERIOR INSULATION AND FINISH SYSTEM

EJ EXPANSION JOINT

ELEC ELECTRICAL

ELEV ELEVATOR OR ELEVATION

EQ EQUAL

EXP EXPOSED STRUCTURE

EXT EXTERIOR

FAB FABRIC

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FFE FINISH FLOOR ELEVATION

FHC FIRE HOSE CABINET

FL FLOOR

FP FLAG POLE

FRP FIBERGLASS REINFORCED PANEL

FS FIRESTOP SYSTEM

FT FOOT or FEET

FTG FOOTING

GA GAUGE

GALV GALVANIZED

GB GYPSUM BOARD

GBT GYPSUM BOARD TRIM

GF GLAZING FILM

GFRC GLASS FIBER REINFORCED CONCRETE

GFRG GLASS FIBER REINFORCED GYPSUM

GL GLAZING

GRT GROUT

H HEIGHT

HB HOSE BIBB

HM HOLLOW METAL

HORIZ HORIZONTAL

INSUL INSULATION

INT INTERIOR

JS JOINT SEALANT

KB KNOX BOX

L LOCKER TYPE AND COLOR

LAV LAVATORY

LD LOADING DOCK EQUIPMENT

LF LIGHT FIXTURE

LV LOUVER

LVT LUXURY VINYL TILE

M.O. MASONRY OPENING

MAX MAXIMUM

MC METAL COPING

MECH MECHANICAL

MFR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MRP METAL ROOF PANEL

MTL METAL

MWP METAL WALL PANEL

(N) NEW

N.I.C. NOT IN CONTRACT

N.T.S. NOT TO SCALE

O.C. ON CENTER

OHD OVERHEAD DOOR

OP OPERABLE PANEL PARTITIOIN

P PAINT

PL PLASTIC LAMINATE

PLY PLYWOOD

PS PROJECTION SCREEN

PVC POLYVINYL CHLORIDE MEMBRANE ROOFING

QT QUARTZ

R.O. ROUGH OPENING

RAD RADIUS

REF REFERENCE

REINF REINFORCED

REQ REQUIRED

RM ROOM

RMT RUBBER MAT

RP ROOF PAVERS

S STUCCO

SCHED SCHEDULE

SF SQUARE FEET

SFRM SPRAYED FIRE-RESISTANT MATERIAL

SFT STOREFRONT

SIM SIMILAR

SJ SEISMIC JOINT

SM SHEET METAL

SPEC SPECIFICATION

SQ SQUARE

SS STAINLESS STEEL

SSU SOLID SURFACE

ST STAIN

STA STATION

STD STANDARD

STL STEEL

STN STONE

STOR STORAGE

STRUC STRUCTURAL

SUSP SUSPENDED

SYM SYMMETRICAL

T TILE

T&G TONGUE AND GROOVE

T.O. TOP OF

T.O.C. TOP OF CONCRETE

T.O.F. TOP OF FRAMING

T.O.M. TOP OF MASONRY

T.O.P. TOP OF PARAPET

T.O.S. TOP OF SHEATHING

T.V. TELEVISION

TA TOILET ACCESSORIES

TC TOILET COMPARTMENTS

TEL TELEPHONE

TG TEMPERED GLASS

TPO THERMOPLASTIC ROOF MEMBRANE

TS TRANSITION STRIP

TYP. TYPICAL

U.O.N. UNLESS OTHERWISE NOTED

V.I.F. VERIFY IN FIELD

V.T.R. VENT THRU ROOF

VERT VERTICAL

VT VINYL TILE

W/ WITH

W/O WITHOUT

WB WALL BASE

WC WATER CLOSET

WCR WALL COVERING

WD WOOD

WF WOOD FLOORING

WM WALK-OFF MAT

WPJ WEAKENED PLANE JOINT

GENERAL NOTES FIRE NOTES

W D

LIVING ROOM

BEDROOM 2

BEDROOM 3

BEDROOM 4

BEDROOM 5

BEDROOM 1

BEDROOM 7

BEDROOM 6

LIVING ROOM

KITCHEN

VESTIBULE

A5.1

A1 A5.1

B1

A5.1

D1

A5.1

C1

BLUE RESTROOM

LAUNDRY

RED RESTROOM

UTILITY

ENTRY HALL

HALLWAY 1

WHITE RESTROOM

B1

A5.1

TYP.

02 05 00.B1

ENTRY HALL

VESTIBULE

BEDROOM 5

HALLWAY 1

BEDROOM 4

BEDROOM 3 LIVING ROOM

LAUNDRY

UTILITY

RED RESTROOM

BEDROOM 6

BEDROOM 7BEDROOM 1

WHITE RESTROOM

LIVING ROOM

KITCHEN

BLUE RESTROOM

BEDROOM 2

26 01 00.A4

26 01 00.A5

23 31 00.A5

23 31 00.A6

26 01 00.A4

26 01 00.A5

23 31 00.A5

26 01 00.A4

26 01 00.A4

26 01 00.A5

23 31 00.A5

EXISTING CEILING MOUNTED LIGHT FIXTURE TO REMAIN

EXISTING CEILING MOUNTED LIGHT FIXTURE TO REMAIN

EXISTING CEILING MOUNTED LIGHT FIXTURE TO REMAIN

1. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS ON

SITE PRIOR TO COMMENCING WORK

2. ALL PLUMBING AND ELECTRICAL FIXTURES TO BE REPLACED IN EXISTING

LOCATION.

3. SEE INTERIOR ELEVATIONS FOR ALL RESTROOM ACCESSORY MOUNTING

HEIGHTS. SEE SPECIFICATIONS FOR ADDITIONAL ACCESSORY INFORMATION

4. ALL FLOORING TRANSITIONS TO OCCUR AT THE CENTERLINE OF THE DOOR

U.N.O. AND MEET ALL GUIDELINES FOR ACCESSIBILITY

5. ALL FINISHES TO CONTINUE UNDER FURNITURE AND EQUIPMENT U.N.O.

6. SEE FINISH LEGEND ON A6.1 FOR ADDITIONAL INFORMATION ON ALL

SCHEDULED MATERIALS

7. FOR ALL EXISTING EQUIPMENT TO REMAIN AND TO BE REUSED, CONTRACTOR

TO STORE AND PROTECT EXISTING EQUIPMENT DURING CONSTRUCTION.

CONTRACTOR TO REINSTALL AND RECONNECT EXISTING EQUIPMENT.

1. CONTRACTOR SHALL VERIFY ALL EXISTING CEILING CONDITIONS PRIOR

TO COMMENCING WORK

2. ALL EXISTING LIGHTING FIXTURES AND ELECTRICAL DEVICES TO BE

REMOVED AND REINSTALLED IN PLACE U.N.O.

3. CONTRACTOR TO VERIFY LOCATIONS OF ALL LIGHTING, MECHANICAL

AND ELECTRICAL DEVICES TO REMAIN AND PROTECT IN PLACE

4. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR LIGHT

FIXTURES, FIXTURE AND EQUIPMENT LOCATIONS AND ADDITIONAL

INFORMATION.

5. SEE SPECIFICATIONS AND CUT SHEET PACKAGE FOR ADDITIONAL

PRODUCT INFORMATION.

6. SEE INTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION.

LVT-1

PROJECT NUMBER:

SHEET TITLE:

NOT FOR

CONSTRUCTION

PROJECT:

SHEET NUMBER:

200 E STREET, SANTA ROSA, CA 95404

707.544.3920 | www.coargroup.com

DESCRIPTION: DATE:

100% SCHEMATIC

DESIGN

6/10/26

90% CDs 7/7/26

100%

CONSTRUCTION

DOCUMENTS

8/11/26

FIRST FLOOR

PLAN & RCP

260501

A2.1

BELLA HOUSE KITCHEN

AND BATHROOM REHAB

NAPA COUNTY

1046 BELLA DR, NAPA, CA,

94558

SCALE: 1/8" = 1'-0"A2.1

B1 FIRST FLOOR PLAN

SCALE: 1/8" = 1'-0"A2.1

D1 FIRST FLOOR REFLECTED CEILING PLAN

CONSTRUCTION NOTES

02 05 00.B1 EXISTING LIGHTING FIXTURE TO REMAIN, REPLACE BULB WITH AN LED

BULB, SEE ELECTRICAL DRAWINGS OTHERWISE

23 31 00.A5 RECESSED CEILING MOUNTED EXHAUST FAN WITH LIGHT (EQID 23-01), SEE

MECHANICAL DRAWINGS

23 31 00.A6 RANGE HOOD EXHAUST DUCTING, SEE MECHANICAL DRAWINGS

26 01 00.A4 CEILING MOUNTED DOWN LIGHT (EQID 26-03), SEE ELECTRICAL DRAWINGS

26 01 00.A5 24" WALL MOUNTED LIGHT FIXTURE (EQID 26-02), SEE ELECTRICAL

DRAWINGS

LEGEND

FLOOR PLAN NOTES

REFLECTED CEILING PLAN NOTES

LEGEND

A1

A5.1

A6.1

A6.1

22 40 00.F8

22 40 00.F9

11 30 13.D3

11 30 13.D4

11 30 13.D5

B1

A5.1

A6.1

10 28 00.D6

10 28 00.D7

10 28 00.D10

22 40 00.F6

22 40 00.F5

10 28 00.D8

22 40 00.F2

22 40 00.A4

22 40 00.F7

C1

A5.1 12 10

A6.1

10 28 00.D6

10 28 00.D7

10 28 00.D8

10 28 00.D9

10 28 00.D10

22 40 00.F5

22 40 00.F3

22 40 00.F4

22 40 00.A4

22 40 00.F2

2'

0"

1'

0"

3'

2'-0"2'-6"2'-0"FILLER

A7.1

A4

A7.1

B4

A7.1

C1

PT

SSU

PL

PL

ENTRY HALL

BEYOND

11 30 13.D4

2' -6

1' -9

3'

-2

2' -1

0"

FILLER 1'-9" 3'-0" 3'-0" 1'-9" FILLER

A7.1

B2

A7.1

B1

PL

SSU

09 72 00.D1

3'

1'

0"

2'

0"

V.I.F.3'-0"

3'-0" 3'-0" 2'-0" 2'-0" 3'-0" 3" FILLER

A7.1

C1

A7.1

A4

A7.1

A2

A7.1

A3

PT

PL

PL

SSU

LIVING ROOM

BEYOND

TYP.

B

11 30 13.D6

FILLER 1' - 9"

3'

1'

0"

2'

0"

A7.1

A4

A7.1

A1

PT

PL

SSU

PL

SSU

PT

FINISHED

3'-3" TYP.

B

2' - 10" 2' - 0" 4' - 0"

4'

"6'

PT

SSU

6'

2' -1

0"

2' - 2"

FILLER 1'-0" 2'-0" 1'-0"

A7.1

D1

A7.1

D2

PL

PT

SSU

SSU

3'-3"

PL

10 28 00.D5

SSU

3'

EQEQ

PT

PL

4'

3' - 0" 4' - 6"

SSU

PT

TYP.

B

SSU

6'

2' -3

2' -1

0"

A7.1

D3

3'-2"

PT

SSU

SSU

1' - 6"11"

3'

2'

10 28 00.D4

FILLER2'-0"

7' -9

A7.1

B3

PT

SSU

PL

2' - 2" 8"

4'

"6'

3'

4' - 0"

SSU

D1

A5.1

D1

A5.1

A6.1

10 28 00.D6

10 28 00.D7

22 40 00.A4

22 40 00.F2

22 40 00.F3

22 40 00.F4

22 40 00.F5 10 28 00.D8

PT

B

3' - 0"

4'

PT

TYP.

B

SSU

4'

1' - 10" 1' - 2"

2'-0"FILLER

A7.1

A3

PT

SSU

PL

SSU

PL

3'-0"

10 28 00.D3

B

SSU

SSU

PT

6'

2' - 1 3/4"

4'

2' - 6"

3'-0"

SSU

SSU

PROJECT NUMBER:

SHEET TITLE:

NOT FOR

CONSTRUCTION

PROJECT:

SHEET NUMBER:

200 E STREET, SANTA ROSA, CA 95404

707.544.3920 | www.coargroup.com

DESCRIPTION: DATE:

100% SCHEMATIC

DESIGN

6/10/26

90% CDs 7/7/26

100%

CONSTRUCTION

DOCUMENTS

8/11/26

INTERIOR

ELEVATIONS

260501

A5.1

BELLA HOUSE KITCHEN

AND BATHROOM REHAB

NAPA COUNTY

1046 BELLA DR, NAPA, CA,

94558

CONSTRUCTION NOTES

09 72 00.D1 1/2" THICK CORK BOARD APPLIED TO WALL (EQID 10-05), PAINTED PT-1 -

SEE FINISH LEGEND

10 28 00.D3 24" x 36" FRAMED MIRROR - SEE D4/A7.1

10 28 00.D4 30" x 36" FRAMED MIRROR - SEE D4/A7.1

10 28 00.D5 48" x 36" FRAMED MIRROR - SEE D4/A7.1

10 28 00.D6 TOWEL BAR (EQID 10-04)

10 28 00.D7 18" VERTICAL GRAB BAR (EQID 10-01)

10 28 00.D8 TOILET PAPER DISPENSER (EQID 10-03)

10 28 00.D9 24" GRAB BAR (EQID 10-01)

10 28 00.D10 36" GRAB BAR (EQID 10-01)

11 30 13.D3 (E) RANGE TO REMAIN - PROTECT IN PLACE

11 30 13.D4 (E) REFRIGERATOR TO REMAIN - PROTECT IN PLACE

11 30 13.D5 RANGE HOOD MICROWAVE COMBO (EQID 11-01), S.E.D. & S.M.D.

OTHERWISE

11 30 13.D6 RELOCATED (E) DISHWASHER, CONTRACTOR TO RELOCATE POWER AND

WET UTILITY CONNECTIONS TO ACCOMMODATE NEW LOCATION

22 40 00.A4 BATHROOM SINK (EQID 22-06), S.P.D.

22 40 00.F2 BATHROOM FAUCET (EQID 22-07), S.P.D.

22 40 00.F3 SHOWER TRIM KIT (EQID 22-03), S.P.D.

22 40 00.F4 SHOWER DRAIN (EQID 22-05), S.P.D.

22 40 00.F5 TOILET (EQID 22-01), S.P.D.

22 40 00.F6 BATH & SHOWER TRIM KIT (EQID 22-02), S.P.D.

22 40 00.F7 BATHTUB (EQID 22-04), S.P.D.

22 40 00.F8 KITCHEN FAUCET (EQID 22-09), S.P.D.

22 40 00.F9 KITCHEN SINK (EQID 22-08), S.P.D.

SCALE: 1/4" = 1'-0"A5.1

A1 ENLARGED PLAN - KITCHEN

SCALE: 1/4" = 1'-0"A5.1

B1 ENLARGED PLAN - BATHROOM 1 - BLUE

SCALE: 1/4" = 1'-0"A5.1

C1 ENLARGED PLAN - BATHROOM 2 - WHITE

SCALE: 1/4" = 1'-0"A5.1

D1 ENLARGED PLAN - BATHROOM 3 - RED

1 2

6 7 85

129 10 11

13 14 15 16 17

WATERPROOFING

RESILIENT (LUXURY VINYL

TILE) FLOORING

EXISTING CARPET

FLOOR TRANSITION STRIP

BETWEEN CARPET AND LVT

(E) SUBFLOOR

RO

DOOR FRAME BEYOND

RESILIENT (LUXURY VINYL TILE)

FLOORING

DOOR AS SCHEDULED

EXISTING CARPET

FLOOR TRANSITION STRIP

BETWEEN CARPET AND LVT

(E) SUBFLOOR

PROJECT NUMBER:

SHEET TITLE:

NOT FOR

CONSTRUCTION

PROJECT:

SHEET NUMBER:

200 E STREET, SANTA ROSA, CA 95404

707.544.3920 | www.coargroup.com

DESCRIPTION: DATE:

100% SCHEMATIC

DESIGN

6/10/26

90% CDs 7/7/26

100%

CONSTRUCTION

DOCUMENTS

8/11/26

ROOM FINISH

SCHEDULE

260501

A6.1

BELLA HOUSE KITCHEN

AND BATHROOM REHAB

NAPA COUNTY

1046 BELLA DR, NAPA, CA,

94558

ROOM FINISH SCHEDULE

ROOMS FLOOR BASE WALLS CEILING CASEWORK

REMARKSDESCRIPTION MATERIAL MATERIAL

NORTH EAST SOUTH WEST

MATERIAL HEIGHT COUNTERTOP CABINETMATERIAL MATERIAL MATERIAL MATERIAL

KITCHEN LVT-1 B-1 PT-1 PT-1 PT-1 PT-1 GYP., PT-2 8' - 0" SSU-1 PL-1 SEE INTERIOR ELEVATIONS AND FINISH SCHEDULE

BLUE RESTROOM LVT-1 B-1 PT-1 PT-1 PT-1 PT-1 GYP., PT-2 8' - 0" SSU-1 PL-1 SEE INTERIOR ELEVATIONS AND FINISH SCHEDULE

RED RESTROOM LVT-1 B-1 PT-1 PT-1 PT-1 PT-1 GYP., PT-2 8' - 0" SSU-1 PL-1 SEE INTERIOR ELEVATIONS AND FINISH SCHEDULE

WHITE RESTROOM LVT-1 B-1 PT-1 PT-1 PT-1 PT-1 GYP., PT-2 8' - 0" SSU-1 - SEE INTERIOR ELEVATIONS AND FINISH SCHEDULE

MATERIAL LEGEND

ABRV. DESCRIPTION

ACT ACOUSTIC CEILING TILE

ASB ACOUSTICAL SUSPENDED BAFFLES

B BRICK

CC COLUMN COVER

CFB CEMENT FIBER BOARD SIDING

CMU CONCRETE MASONRY UNIT

CNC CONCRETE

CP CORNER PROTECTION

CPT CARPET

CT CERAMIC/PORCELAIN TILE

CW CURTAIN WALL

CWP COMPOSITE METAL WALL PANEL

DEFS DIRECT-APPLIED EXTERIOR FINISH SYSTEM

EIFS EXTERIOR INSULATION & FINISH SYSTEM

EXP EXPOSED STRUCTURE

FAB FABRIC

FRP FIBERGLASS REINFORCED PLASTIC

GB-1 GYPSUM WALL BOARD, 5/8" UON

GB-2 GYPSUM WALL BOARD, SOUND ABSORBENT

GB-3 GYPSUM WALL BOARD, FIRE RESISTANT (5/8") TYPE-X

GB-4 GYPSUM WALL BOARD, WATER RESISTANT (5/8")

GBT GYPSUM BOARD TRIM

GF GLAZING FILM

GFRC GLASS FIBER REINFORCED CEMENT

GFRG GLASS FIBER REINFORCED GYPSUM

GL GLAZING

GRT GROUT

JS JOINT SEALANT

L LOCKER

LV LOUVERS

LVT LUXURY VINYL TILE

MC METAL COPING

MRP METAL ROOF PANEL

MTL METAL FINISH

MWP METAL WALL PANEL

OHD OVERHEAD DOOR

OP OPERABLE PANEL PARTITION

P PAINT

PL PLASTIC LAMINATE

PLY PLYWOOD, PAINTED, 1/2" UON

PVC POLYVINYL CHLORIDE MEMBRANE ROOFING

QTZ QUARTZ

RMT RUBBER MAT

RP ROOF PAVERS

S STUCCO - PORTLAND CEMENT PLASTER

SFT STOREFRONT

SS STAINLESS STEEL

SSU SOLID SURFACE

ST STAIN

STN STONE

TC TOILET COMPARTMENTS

TPO THERMOPLASTIC MEMBRANE ROOFING

VT VINYL TILE

WB WALL BASE

WCR WALL COVERING

WD WOOD

WF WOOD FLOORING

WM WALK-OFF MAT

WT WINDOW TREATMENT

FINISH SCHEDULE

MATERIAL TYPE

DESCRIPTION

COMMENTSNAME MANUFACTURER STYLE COLOR

B 1 FLOOR BASE TARKETT / JOHNSONITE MONUMENT MW-XX-S4 (4") 08 ICICLE STANDARD BASE

LVT 1 LUXURY VINYL TILE TILEBAR HEIGHTS - LOOSE LAY 9"x60" COUNTRYSIDE KITCHEN, RESTROOMS

PL 1 PLASTIC LAMINATE WILSONART - 8242-33 JUBILEE OAK CASEWORK

PT 1 PAINT PPG EGGSHELL CANDLELIT BEIGE (1207-1) FIELD COLOR, SEE NAPA APPROVED COLORS

PT 2 PAINT PPG SEMI-GLOSS DELICATE WHITE (1001-1) INTERIOR DOORS & CASING, SEE NAPA

APPROVED COLORS

SSU 1 SOLID SURFACE WILSONART STANDARD (1/2") 9208CS WHITE STONE COUNTERTOP & BACKSPLASH

SSU 2 SOLID SURFACE AVONITE WET WALL (1/4") 9117 KOKOURA SHOWER WALLS

SSU 3 SOLID SURFACE AVONITE STANDARD (1/2") 9117 KOKOURA SHOWER PANS

DOOR SCHEDULE

DOOR FRAME DETAIL

REMARKSMARK WIDTH HEIGHT DEPTH MATERIAL FINISH MATERIAL FINISH THRESHOLD

101 3' - 0" 7' - 0" 0' - 1 3/4" WD P-2 WD P-2 1/A6.1 EXISTING DOOR AND DOOR FRAME TO REMAIN AND RECEIVE NEW PAINT, SEE FINISH SCHEDULE

102 3' - 0" 7' - 0" 0' - 1 3/4" WD P-2 WD P-2 1/A6.1 EXISTING DOOR AND DOOR FRAME TO REMAIN AND RECEIVE NEW PAINT, SEE FINISH SCHEDULE

103 3' - 0" 7' - 0" 0' - 1 3/4" WD P-2 WD P-2 1/A6.1 EXISTING DOOR AND DOOR FRAME TO REMAIN AND RECEIVE NEW PAINT, SEE FINISH SCHEDULE

SCALE: 6" = 1'-0"A6.1

2 TRANSITION AT LVT TO CARPET

SCALE: 3" = 1'-0"A6.1

1 DOOR & FRAME - INTERIOR THRESHOLD

4"

1 1/2"

1/

2"

8"

COUNTERTOP, SEE FINISH SCHEDULE

EASED EDGE, TYP.

FULL EXTENSION DRAWER SLIDES,

PROVIDE BRACING AS REQUIRED

PULL, ALL PULLS SHALL ALIGN, TYP.

PLASTIC LAMINATE CASEWORK, SEE

FINISH SCHEDULE

PLASTIC LAMINATE BASE

U.O.N. ON ENLARGED PLANS

1'-6"

BACKSPLASH WHERE OCCURS, SEE

FINISH SCHEDULE AND ELEVATIONS

3"

2' -1

0"

WHITE MELAMINE FINISH, TYP.

8"

4"

1 1/2"

1/

2"

COUNTERTOP, SEE FINISH SCHEDULE

EASED EDGE, TYP.

FULL EXTENSION DRAWER SLIDES,

PROVIDE BRACING AS REQUIRED

PULL, ALL PULLS SHALL ALIGN, TYP.

PLASTIC LAMINATE CASEWORK, SEE

FINISH SCHEDULE

PLASTIC LAMINATE BASE

U.O.N. ON ENLARGED PLANS

2'-0"

BACKSPLASH WHERE OCCURS, SEE

FINISH SCHEDULE AND ELEVATIONS

2' -1

0"

WHITE MELAMINE FINISH, TYP.

6" 6"

3"

U .O

.N . O

N

IN

T E

R

IO

R E

LE

V

A T

IO

N

S

2' -1

0"

4"

1 1/2"

1/

2"

COUNTERTOP, SEE FINISH SCHEDULE

EASED EDGE, TYP.

PLASTIC LAMINATE BASE

U.O.N. ON ENLARGED PLANS

2'-0"

ADJUSTABLE SHELF STANDARDS &

SUPPORTS

3/4" MELAMINE FACED PLYWOOD

SHELVING

WHITE MELAMINE FINISH, TYP.

BACKSPLASH WHERE OCCURS, SEE

FINISH SCHEDULE AND ELEVATIONS

3"

PLASTIC LAMINATE CASEWORK, SEE

FINISH SCHEDULE

PULL, ALL PULLS SHALL ALIGN, TYP.

U .O

.N . O

N

IN

T E

R

IO

R E

LE

V

A T

IO

N

S

2' -1

0"

U.O.N. ON ENLARGED PLANS

2'-0"

1/

2"

6"

PLASTIC LAMINATE CASEWORK, SEE

FINISH SCHEDULE

WHITE MELAMINE FINISH, TYP.

PULL, ALL PULLS SHALL ALIGN, TYP.

BACKSPLASH WHERE OCCURS, SEE

FINISH SCHEDULE AND ELEVATIONS

COUNTERTOP, SEE FINISH SCHEDULE

EASED EDGE, TYP.

PLASTIC LAMINATE BASE

4"

3"

DRAWER PANEL

1 1/2"

V A

R

IE

S , S

E E

IN

T

E R

IO

R

E

LE

V A

T

IO

N S

3"

SCRIBE TO CEILING WHERE OCCURS

ADJUSTABLE SHELF STANDARDS &

SUPPORTS

ADJUSTABLE WOOD SHELF, TYP.

WHITE MELAMINE FINISH, TYP.

PULL, ALL PULLS SHALL ALIGN, TYP.

PLASTIC LAMINATE CASEWORK, SEE

FINISH SCHEDULE

1'-3"

3"

3"

SCRIBE TO CEILING WHERE OCCURS

PULL, ALL PULLS SHALL ALIGN, TYP.

PLASTIC LAMINATE CASEWORK, SEE

FINISH SCHEDULE

1'-3"

3"

WHITE MELAMINE FINISH, TYP.

2' -1

0"

6"

2'-0"

1 1/2"

1/

2"

EASED EDGE, TYP.

COUNTERTOP, SEE FINISH SCHEDULE

FULL EXTENSION DRAWER SLIDES,

PROVIDE BRACING AS REQUIRED

PLASTIC LAMINATE BASE

PULL, ALL PULLS SHALL ALIGN, TYP.

ADJUSTABLE WOOD SHELF, TYP.

3"

4"

PLASTIC LAMINATE CASEWORK, SEE

FINISH SCHEDULE

ADJUSTABLE SHELF STANDARDS &

SUPPORTS

WHITE MELAMINE FINISH, TYP.

3' -2

1'

-9

CORK BOARD APPLIED TO WALL AND

PAINTED P-1, SEE FINISH LEGEND

3"

2'-2"

PULL, ALL PULLS SHALL ALIGN, TYP.

ADJUSTABLE WOOD SHELF, TYP.

WHITE MELAMINE FINISH, TYP.

PLASTIC LAMINATE CASEWORK, SEE

FINISH SCHEDULE

3"

WHITE MELAMINE FINISH, TYP.

4"

ADJUSTABLE SHELF STANDARDS &

SUPPORTS

PLASTIC LAMINATE BASE

SCRIBE TO CEILING WHERE OCCURS

1' -2

3"

SCRIBE TO CEILING WHERE OCCURS

WHITE MELAMINE FINISH, TYP.

PULL, ALL PULLS SHALL ALIGN, TYP.

PLASTIC LAMINATE CASEWORK, SEE

FINISH SCHEDULE

1'-3"

3"

MICROWAVE HOOD EXHAUST DUCT AS

OCCURS, S.M.D. - SEE MECHANICAL

MICROWAVE HOOD, S.M.D. - SEE

SPECIFICATIONS

2' -1

0"

6"

2'-0"

1 1/2"

1/

2"

EASED EDGE, TYP.

COUNTERTOP, SEE FINISH SCHEDULE

BACKSPLASH WHERE OCCURS, SEE

FINISH SCHEDULE AND ELEVATIONS

FULL EXTENSION DRAWER SLIDES,

PROVIDE BRACING AS REQUIRED

PLASTIC LAMINATE BASE

PULL, ALL PULLS SHALL ALIGN, TYP.

ADJUSTABLE WOOD SHELF, TYP.

3"

4"

PLASTIC LAMINATE CASEWORK, SEE

FINISH SCHEDULE

ADJUSTABLE SHELF STANDARDS &

SUPPORTS

WHITE MELAMINE FINISH, TYP.

2' -1

0"

U.O.N. ON ENLARGED PLANS

1'-8"

1/

2"

6"

PLASTIC LAMINATE CASEWORK, SEE

FINISH SCHEDULE

WHITE MELAMINE FINISH, TYP.

PULL, ALL PULLS SHALL ALIGN, TYP.

BACKSPLASH WHERE OCCURS, SEE

FINISH SCHEDULE AND ELEVATIONS

COUNTERTOP, SEE FINISH SCHEDULE

EASED EDGE, TYP.

PLASTIC LAMINATE BASE

4"

3"

DRAWER PANEL

1 1/2"

1/

2"

EASED EDGE, TYP.

SOLID SURFACE COUNTERTOP W/

IN-WALL STEEL SUPPORTS - SCRIBE TO

WALL

KNEE AND TOE CLEARANCE

M

IN

9" M

IN

1"

6" MIN

8" MIN

11" MIN

2'-0"

5"

2' -1

0"

SOLID SURFACE APRON

BATHROOM SINK (EQID 22-06), S.P.D.

BACKSPLASH WHERE OCCURS, SEE

FINISH SCHEDULE AND ELEVATIONS

E Q

E Q

2'-2"

ADJUSTABLE WOOD SHELF, TYP.

WHITE MELAMINE FINISH, TYP.

PLASTIC LAMINATE CASEWORK, SEE

FINISH SCHEDULE

3"

WHITE MELAMINE FINISH, TYP.

4"

ADJUSTABLE SHELF STANDARDS &

SUPPORTS

PLASTIC LAMINATE BASE3"

SCRIBE TO CEILING WHERE OCCURS

TEMPERED GLASS

MIRROR

MIRROR FRAME,

PLASTIC LAMINATE

ALL EXPOSED SIDES

2X BLOCKING

WALL PER PLAN

ALUMINUM MOUNTING BRACKET PROJECT NUMBER:

SHEET TITLE:

NOT FOR

CONSTRUCTION

PROJECT:

SHEET NUMBER:

200 E STREET, SANTA ROSA, CA 95404

707.544.3920 | www.coargroup.com

DESCRIPTION: DATE:

100% SCHEMATIC

DESIGN

6/10/26

90% CDs 7/7/26

100%

CONSTRUCTION

DOCUMENTS

8/11/26

CABINET DETAILS

260501

A7.1

BELLA HOUSE KITCHEN

AND BATHROOM REHAB

NAPA COUNTY

1046 BELLA DR, NAPA, CA,

94558

SCALE: 1" = 1'-0"A7.1

D1 3-DRW BASE CABINET

SCALE: 1" = 1'-0"A7.1

A2 4-DRW BASE CABINET

SCALE: 1" = 1'-0"A7.1

A1 BASE CABINET

SCALE: 1" = 1'-0"A7.1

A3 SINK BASE CABINET

SCALE: 1" = 1'-0"A7.1

A4 UPPER CABINET

SCALE: 1" = 1'-0"A7.1

B1 CABINET AND SHELF

SCALE: 1" = 1'-0"A7.1

B2 TALL CABINET

SCALE: 1" = 1'-0"A7.1

B4 UPPER CABINET

SCALE: 1" = 1'-0"A7.1

C1 BASE CABINET

SCALE: 1" = 1'-0"A7.1

D2 SINK BASE CABINET 2

SCALE: 1" = 1'-0"A7.1

D3 COUNTERTOP WITH LAVATORY

SCALE: 1" = 1'-0"A7.1

B3 TALL CABINET

SCALE: 1 1/2" = 1'-0"A7.1

D4 MIRROR WALL MOUNTING

W D

LIVING ROOM

BEDROOM 2

BEDROOM 3

BEDROOM 4

BEDROOM 5

BEDROOM 1 BEDROOM 7

BEDROOM 8

BEDROOM 6

KITCHEN

VESTIBULE

BATH 1

LAUNDRY

BATH 3

UTILITY

ENTRY

HALLWAY 1

BATH 2

PROJECT NUMBER:

SHEET TITLE:

PROJECT:

SHEET NUMBER:

200 E STREET, SANTA ROSA, CA 95404

707.544.3920 | www.coargroup.com

DESCRIPTION: DATE:

100% SCHEMATIC

DESIGN

6/10/26

260501

NAPA COUNTY BELLA

REHAB

NAPA COUNTY

1046 BELLA DR, NAPA, CA,

94558

100% CONSTRUCTION

DOCUMENTS

6/26/26

MECHANICAL

FIRST FLOOR

PLANS

M101

SCALE: 1/4" = 1'-0"M101 FIRST FLOOR MECHANICAL PLAN

100% SCHEMATIC

DESIGN

6/10/26

90% CDs 7/7/26

100%

CONSTRUCTION

DOCUMENTS

8/11/26

PROJECT NUMBER:

SHEET TITLE:

PROJECT:

SHEET NUMBER:

200 E STREET, SANTA ROSA, CA 95404

707.544.3920 | www.coargroup.com

DESCRIPTION: DATE:

100% SCHEMATIC

DESIGN

6/10/26

260501

NAPA COUNTY BELLA

REHAB

NAPA COUNTY

1046 BELLA DR, NAPA, CA,

94558

100% CONSTRUCTION

DOCUMENTS

6/26/26

MECHANICAL

SCHEDULES,

DETAILS AND

LEGEND

M601

100% SCHEMATIC

DESIGN

6/10/26

90% CDs 7/7/26

100%

CONSTRUCTION

BEDROOM 2

BEDROOM 3

BEDROOM 4

BEDROOM 5

BEDROOM 1 BEDROOM 7

BEDROOM 8

BEDROOM 6

KITCHEN

VESTIBULE

BATH 1

LAUNDRY

BATH 3

UTILITY

ENTRY

HALLWAY 1

BATH 2

PROJECT NUMBER:

SHEET TITLE:

PROJECT:

SHEET NUMBER:

200 E STREET, SANTA ROSA, CA 95404

707.544.3920 | www.coargroup.com

DESCRIPTION: DATE:

100% SCHEMATIC

DESIGN

6/10/26

260501

NAPA COUNTY BELLA

REHAB

NAPA COUNTY

1046 BELLA DR, NAPA, CA,

94558

100% CONSTRUCTION

DOCUMENTS

6/26/26

PLUMBING

FIRST FLOOR

PLANS

P101

SCALE: 1/4" = 1'-0"P101 FIRST FLOOR PLUMBING PLAN

100% SCHEMATIC

DESIGN

6/10/26

90% CDs 7/7/26

100%

CONSTRUCTION

PROJECT NUMBER:

SHEET TITLE:

PROJECT:

SHEET NUMBER:

200 E STREET, SANTA ROSA, CA 95404

707.544.3920 | www.coargroup.com

DESCRIPTION: DATE:

100% SCHEMATIC

DESIGN

6/10/26

260501

NAPA COUNTY BELLA

REHAB

NAPA COUNTY

1046 BELLA DR, NAPA, CA,

94558

100% CONSTRUCTION

DOCUMENTS

6/26/26

PLUMBING

SCHEDULES,

DETAILS AND

LEGEND

P601

100% SCHEMATIC

DESIGN

6/10/26

90% CDs 7/7/26

100%

CONSTRUCTION

TYP.

02 05 00.B1

ENTRY HALL

VESTIBULEBEDROOM 5

HALLWAY 1

BEDROOM 4

BEDROOM 3 BEDROOM 6

LAUNDRY

UTILITY

BATHROOM 3

BEDROOM 8

BEDROOM 7BEDROOM 1

BATHROOM 2LIVING ROOM

KITCHEN

BATHROOM 1

BEDROOM 2

1 2 TYPICAL

NUMBERED SHEET NOTES

RE-LAMP ALL (E) LIGHT FIXTURES IN THE RESIDENCE WITH (N)

LED EQUIVALENT LAMPS; 2700K COLOR TEMPERATURE, 80CRI,

DIMMABLE. FIELD VERIFY ALL (E) WATTAGES AND PROVIDE LED

WITH MATCHING LUMEN OUTPUT.

ALL (E) CONTROLS TO REMAIN. NO RE-WIRING, EXCEPT AS

NOTED ON SHEET E3.1

PROJECT:

DESCRIPTION: DATE:

PROJECT NUMBER:

SHEET TITLE:

SHEET NUMBER:

200 E STREET, SANTA ROSA, CA 95404

619.698.9177 | www.coargroup.com

Exp. 6/27

RE

DN

ARBNELOC.J

RETEI P

RE

EN

IG

NE

LAN

OISSEFORP

DERETSI

GER

C

LIFOAF C

TRI

RN

AALE C I

ET

AT

S LE

No.E14738

O

NOT FOR

CONSTRUCTION

260501

NAPA COUNTY BELLA

REHAB

NAPA COUNTY

1046 BELLA DR, NAPA, CA,

94558

7/2/26BID SET

FIRST FLOOR

PLAN - LIGHTING

E2.11 E2.1

FIRST FLOOR PLAN - LIGHTING

1/4" = 1'-0"SCALE:

100% SCHEMATIC

DESIGN

6/10/26

90% CDs 7/7/26

100%

CONSTRUCTION

BEDROOM 2

BEDROOM 3

BEDROOM 4

BEDROOM 5

BEDROOM 1 BEDROOM 7

BEDROOM 8

BEDROOM 6

KITCHEN

VESTIBULE

BATHROOM 1

LAUNDRY

BATHROOM 3

UTILITY

ENTRY HALL

HALLWAY 1

BATHROOM 2

O S

OS

OS

(E) HOUSE PANEL 'A' 7

E-3 1

GFI

A-19

A-19

E-2 1

E-1 1

NUMBERED SHEET NOTES

FLUSH CEILING MOUNTED COMBINATION LIGHT / EXHAUST FAN

(BY MECHANICAL). CONNECT COMPLETE TO (E) EXHAUST / LIGHT

FAN CIRCUIT FOR BATHROOM, VIA NEW CONTROLS SHOWN. ALL

LIGHTS AND EXHAUST FAN IN ROOM TO BE SWITCHED IN

PARALLEL.

RANGE HOOD / MICROWAVE COMBINATION UNIT (BY OTHERS).

CONNECT COMPLETE TO NEW CIRCUIT AS SHOWN.

PROVIDE AND INSTALL (N) IR STYLE WALL SWITCH VACANCY

SENSOR (MANUAL-ON, AUTO-OFF WITH 20 MINUTE DELAY), TO

REPLACE (E) DUAL SWITCHES. PROVIDE (N) 2-GANG WALL PLATE

WITH 1-GANG OPENING FOR SINGLE SWITCH VACANCY SENSOR.

PROVIDE AND INSTALL (N) 24" LINEAR LED OVER-MIRROR LIGHT

FIXTURE TO REPLACE (E) FIXTURE; KOHLER MODEL CRUE

K-32631-SCLED. RECONNECT COMPLETE AS SHOWN, VIA NEW

CONTROLS.

PROVIDE AND INSTALL (N) 11" ROUND LED CEILING LIGHT

FIXTURE TO REPLACE (E) FIXTURE; JUNO MODEL SLIMFORM #JSF

11IN. RECONNECT COMPLETE AS SHOWN, VIA NEW CONTROLS.

PROVIDE AND INSTALL (N) DUAL 20A/1P BRANCH BREAKER IN (E)

SPACES 19 AND 20. NEW BREAKER TO MATCH (E) IN

MANUFACTURER AND TYPE.

PROVIDE AND INSTALL (N) RECEPTACLE FOR (N) MICROWAVE.

COORDINATE EXACT LOCATION WITH MICROWAVE EQUIPMENT,

PRIOR TO ROUGH-IN.

PROJECT:

DESCRIPTION: DATE:

PROJECT NUMBER:

SHEET TITLE:

SHEET NUMBER:

200 E STREET, SANTA ROSA, CA 95404

619.698.9177 | www.coargroup.com

Exp. 6/27

RE

DN

ARBNELOC.J

RETEI P

RE

EN

IG

NE

LAN

OISSEFORP

DERETSI

GER

C

LIFOAF C

TRI

RN

AALE C I

ET

AT

S LE

No.E14738

O

NOT FOR

CONSTRUCTION

260501

NAPA COUNTY BELLA

REHAB

NAPA COUNTY

1046 BELLA DR, NAPA, CA,

94558

7/2/26BID SET

FIRST FLOOR

PLAN -

ELECTRICAL

E3.11 E2.1

FIRST FLOOR PLAN - LIGHTING

1/4" = 1'-0"SCALE:

W D

LAUNDRY

W D

LAUNDRY

NOT USED

100% SCHEMATIC

DESIGN

6/10/26

90% CDs 7/7/26

100%

CONSTRUCTION

GENERAL
T-1 - TITLE SHEET
T-2 - TITLE SHEET
ARCHITECTURAL
A2.1 - FIRST FLOOR PLAN & RCP
A5.1 - INTERIOR ELEVATIONS
A6.1 - ROOM FINISH SCHEDULE
A7.1 - CABINET DETAILS
MECHINICAL
M101 MECHANICAL FIRST FLOOR PLANS
M601 MECHANICAL SCHEDULES, DETAILS AND LEGEND
PLUMBING
P101 PLUMBING FIRST FLOOR PLANS
P601 PLUMBING SCHEDULES, DETAILS AND LEGEND
ELECTRICAL
E2.1 FIRST FLOOR PLAN - LIGHTING
E3.1 FIRST FLOOR PLAN - ELECTRICAL

File details come from the government source that posted it. Updated .