About this file
Bella House Kitchen and Bathroom Rehab - Construction Plans Summary
This is a 100% construction document set prepared by COAR Design Group for Napa County's Bella House facility located at 1046 Bella Drive, Napa, California. The project scope encompasses a tenant improvement rehabilitation of an existing licensed social rehabilitation facility that provides mental health residential services for up to 12 adults. The rehabilitation work includes complete demolition and replacement of kitchen and bathroom equipment, fixtures, casework, and flooring finishes; installation of new plumbing, electrical, and mechanical systems; interior painting; and LED light bulb replacement throughout the facility. The design package includes architectural, mechanical, plumbing, and electrical drawings prepared under 2025 California Building Code standards, with construction documents completed as of August 11, 2026. The project is classified as RS-10 construction type with occupancy group V-B, sprinklered, and includes three bathrooms (identified as Blue, White, and Red Restroom) and one kitchen requiring rehabilitation. A critical sequencing constraint requires that only one restroom be taken out of service at any given time during construction, as the facility will remain occupied and operational with residents throughout the project duration. Contractor must coordinate all work activities with facility and County staff to minimize disruption to residents and must not commence work prior to the notice to proceed date specified in the project's Special Provisions and General Conditions.
The construction documents detail comprehensive specifications for materials, finishes, fixtures, and equipment including luxury vinyl tile flooring, gypsum board walls finished in PPG paint, plastic laminate casework with solid surface countertops and backsplashes, and bathroom fixtures with grab bars and accessibility features. The design incorporates fire safety requirements including fire-extinguishing system specifications, fire alarm systems, sprinkler flow alarms, and egress illumination standards. Mechanical work involves HVAC systems and exhaust fans; plumbing work includes sink installations, faucets, toilets, bathtubs, and shower systems; and electrical work comprises LED lighting fixture installations, receptacle placement, and circuit upgrades including two new 20-amp single-pole branch breakers. The project team includes Lefler Engineering Inc. (Civil/Mechanical), COAR Design Group (Architecture), O'Mahony & Myer (Plumbing/Electrical), and Napa County as the owner with Roberto De La Torre Real as the County contact. All work must comply with Napa County requirements and California Building Standards Code Title 24, with construction observation and compliance affidavits required from a registered California architect or engineer.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SITE
1046 BELLA DRIVE
NAPA, CA 94558
036-213-002-000
COUNTY OF NAPA
1195 THIRD STREET, #210
NAPA, CA 94559
2025 CALIFORNIA BUILDING CODE
2025 CALIFORNIA FIRE CODE
2025 CALIFORNIA ENERGY CODE
2025 CALIFORNIA GREEN BUILDING STANDARDS
2025 CALIFORNIA ELECTRICAL CODE
2025 CALIFORNIA MECHANICAL CODE
2025 CALIFORNIA PLUMBING CODE
2025 CALIFORNIA EXISTING BUILDING CODE
RS 10
V-B
YES
OCCUPANCY GROUP(S)
PROJECT ADDRESS:
ASSESSOR'S PARCEL NUMBER:
GOVERNING AGENCY:
GOVERNING CODES:
ZONING:
CONSTRUCTION TYPE:
SPRINKLERED:
OCCUPANCIES:
LEFLER ENGINEERING INC.
1651 SECOND STREET
SAN RAFAEL, CA 94901
(415) 456-4220 Contact: TREVOR LEFLER
TREVOR@LEFLERENGINEERING.COM
ARCHITECTURE
COAR Design Group
Contact: JEFF KATZ, AIA
JEFF@COARGROUP.COM
PLUMBING ELECTRICAL
O'MAHONY & MYER
4340 REDWOOD HIGHWAY #245
SAN RAFAEL, CA 94903
(415) 492-0420 Contact: PIETER COLENBRANDER, PE, LEED AP
PCOLENBRANDER@OMMCONSULTING.COM
OWNER
COUNTY OF NAPA
1195 THIRD STREET, SUITE 101
NAPA, CA 94559
(707) 253-4417 Contact: ROBERTO DE LA TORRE REAL
ROBERTO.DELATORREREAL@COUNTYOFNAPA.ORG
MECHANICAL
200 E STREET
SANTA ROSA, CA 95404
(707) 544-3920
LEFLER ENGINEERING INC.
1651 SECOND STREET
SAN RAFAEL, CA 94901
(415) 456-4220 Contact: TREVOR LEFLER
TREVOR@LEFLERENGINEERING.COM
SCOPE OF WORK: TENANT IMPROVEMENT OF AN EXISTING FACILITY. UPDATING INTERIOR
FINISHES OF RESTROOMS AND KITCHEN.
SITE
A REGISTERED CALIFORNIA ARCHITECT, CIVIL OR STRUCTURAL ENGINEER SHALL OBSERVE
THE WORK OF CONSTRUCTION AND SUBMIT AFFIDAVITS ATTESTING TO THE COMPLIANCE OF
THE CONSTRUCTION WITH THE APPROVED CONTRACT DOCUMENTS.
NOTE:
PROJECT NUMBER:
SHEET TITLE:
NOT FOR
CONSTRUCTION
PROJECT:
SHEET NUMBER:
200 E STREET, SANTA ROSA, CA 95404
707.544.3920 | www.coargroup.com
DESCRIPTION: DATE:
100% SCHEMATIC
DESIGN
6/10/26
90% CDs 7/7/26
100%
CONSTRUCTION
DOCUMENTS
8/11/26
TITLE SHEET
260501
T-1
BELLA HOUSE KITCHEN
AND BATHROOM REHAB
NAPA COUNTY
1046 BELLA DR, NAPA, CA,
94558
BELLA HOUSE KITCHEN AND BATHROOM REHAB
1046 BELLA DR, NAPA, CA, 94558
LOCATION MAP
PROJECT DATA PROJECT TEAMSCOPE OF WORK
VICINITY MAP
JUAN S. ARIAS COUNTY ENGINEER R.C.E. #C63365
GRID
DETAIL
BUILDING SECTION
WALL TYPE
WINDOW TYPE
DOOR NUMBER
ROOM NUMBER
DATUM POINT
CORNER GUARD
FIRE EXTINGUISHER
CONTINUOUS, UNOBSTRUCTED AND
UNDIMINISHED PATH OF TRAVEL
ROOM NAME
ROOM NUMBER
INTERIOR ELEVATION
CG
FE
BUNK
AT LEAST ONE PORTABLE FIRE EXTINGUISHER WITH A MINIMUM RATING OF 2A10BC
SHALL BE PROVIDED WITHIN 75' MAXIMUM TRAVEL DISTANCE FOR EACH 3,000
SQUARE FEET OR PORTION THEREOF ON EACH FLOOR (CFC 906, UFC STANDARD
10-1, TITLE 19, SECT. 3.29). SEE PLANS FOR LOCATIONS.
AT LEAST ONE FIRE EXTINGUISHER WITH A MINIMUM RATING OF 4A2OBC SHALL BE
PROVIDED OUTSIDE OF EACH MECHANICAL, ELECTRICAL OR BOILER ROOM. (CFC
906, UFC STANDARD 10-1, TITLE 19, SECT. 3.29). SEE PLANS FOR LOCATIONS.
COMPLETE PLANS AND SPECIFICATIONS FOR FIRE-EXTINGUISHING SYSTEMS,
INCLUDING AUTOMATIC SPRINKLERS AND WET AND DRY STANDPIPES, HALON
SYSTEMS AND OTHER SPECIAL TYPES OF AUTOMATIC FIRE-EXTINGUISHING SYSTEMS,
BASEMENT PIPE INLETS, AND OTHER FIRE-PROTECTION SYSTEMS AND
APPURTENANCES THERETO SHALL BE SUBMITTED BY THE CONTRACTOR TO FIRE AND
LIFE SAFETY FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. (CFC 901.2)
FIRE-EXTINGUISHING SYSTEMS SHALL BE INSTALLED BY THE CONTRACTOR IN
ACCORDANCE WITH CBC 903.
ALL VALVES CONTROLLING THE WATER SUPPLY FOR AUTOMATIC SPRINKLER
SYSTEMS AND WATER-FLOW SWITCHES ON ALL SPRINKLER SYSTEMS SHALL BE
ELECTRICALLY MONITORED WHERE THE NUMBER OF SPRINKLERS IS 100 OR MORE.
(CBC 904.3.1, CFC 903.4)
COMPLETE PLANS AND SPECIFICATIONS FOR FIRE ALARM SYSTEMS INCLUDING
AUTOMATIC SPRINKLERS SHALL BE SUBMITTED BY THE CONTRACTOR TO THE FIRE
MARSHAL FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. (CFC 1001.3)
INSTALLATION OF FIRE ALARM SYSTEMS SHALL BE IN ACCORDANCE WITH CFC 907.
AN APPROVED AUDIBLE SPRINKLER FLOW ALARM SHALL BE PROVIDED ON THE
EXTERIOR OF THE BUILDING IN AN APPROVED LOCATION. AN APPROVED AUDIBLE
SPRINKLER FLOW ALARM TO ALERT THE OCCUPANTS SHALL BE PROVIDED IN THE
INTERIOR OF THE BUILDING IN A NORMALLY OCCUPIED LOCATION.
ANY TIME A BUILDING IS OCCUPIED THE MEANS OF EGRESS SHALL BE ILLUMINATED
AT AN INTENSITY OF NOT LESS THEN 1 FOOT-CANDLE AT THE FLOOR LEVEL.
EGRESS ILLUMINATION REQUIRES A SOURCE OF EMERGENCY POWER WHEN THE
OCCUPANT LOAD IS 100 OR MORE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
DIMENSIONS SHOWN ON THE FLOOR PLANS, SECTIONS AND DETAILS ARE TO FACE OF
STUDS, COLUMN GRID LINES AND FACE OF CONCRETE AND BLOCK WALLS, UNLESS
OTHERWISE NOTED OR SHOWN.
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS BEFORE
PROCEEDING WITH CONSTRUCTION.
ALL ITEMS ARE BASE BID UNLESS OTHERWISE NOTED OR SPECIFIED.
ALL DRAIN LINES WITHIN WALLS ARE TO BE WRAPPED IN SOUND INSULATION BATTS.
EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT USE OF A KEY OR ANY
SPECIAL KNOWLEDGE.
CONTRACTOR SHALL PROVIDE ACCESS PANELS REQUIRED BY THE PLUMBING, AIR
CONDITIONING AND OTHER INSTALLERS, AS REQUIRED BY CODE. ANY ACCESS PANEL IN
A FIRE RATED WALL OR CEILING SHALL HAVE THE SAME FIRE RATING AS THE WALL OR
CEILING IN WHICH THEY OCCUR.
STRUCTURAL AND FIRE RESISTIVE INTEGRITY SHALL BE MAINTAINED AT PENETRATIONS FOR
MECHANICAL, PLUMBING, ELECTRICAL, AND COMMUNICATIONS PIPE, DUCT AND
CONDUIT AS INDICATED.
PROVIDE FIRE BLOCKING AT FLOOR, CEILING AND MID HEIGHT OF WALLS OVER 10'-0".
STUCCO, PLASTER AND GYPSUM BOARD SHALL TERMINATE WITH A "J" MOLDING WHERE
THE EDGE IS EXPOSED UNLESS NOTED OR SPECIFIED OTHERWISE.
A FLOOR OR LANDING NOT MORE THE 1/4" BELOW THE THRESHOLD IS REQUIRED AT EACH
SIDE OF AN EXIT DOOR.
BRAND OR TRADE NAME, SUBSTITUTIONS OF "EQUALS": REQUESTS FOR SUBSTITUTIONS OF
AN ITEM AS AN "EQUAL" TO ANY ITEM INDICATED OR SPECIFIED MUST BE INCLUDED AS A
PART OF THE CONTRACTOR'S BID PROPOSAL, AS SPECIFIED IN THE GENERAL CONDITIONS.
WRITTEN DIMENSIONS TAKE PRECEDENCE OVER GRAPHIC SCALE. DO NOT SCALE
DRAWINGS.
IT SHOULD BE NOTED THAT WHILE EXISTING UTILITY DRAWINGS ARE AVAILABLE, THERE IS
NO ASSURANCE THAT ALL UTILITIES ARE SHOWN. THE CONTRACTOR SHALL PROCEED WITH
CAUTION TO INSURE THAT ALL UTILITIES ENCOUNTERED, WHETHER OR NOT OF RECORD,
SHALL BE PROTECTED FROM DAMAGE. THE CONTRACTOR SHALL ALSO TAKE
PRECAUTIONS NECESSARY TO PROTECT HIMSELF AND ALL EMPLOYEES FROM INJURY
WHICH MAY BE CAUSED BY CONTACT WITH UTILITY SERVICES.
GYPSUM BOARD FOR FIRE RATED ASSEMBLIES SHALL BE INSTALLED IN ACCORDANCE
WITH CBC CHAPTER 7.
DOOR HARDWARE SHALL BE LEVER TYPE.
MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR
DOORS AND 5 POUNDS FOR INTERIOR DOORS.
FIRE DAMPER ASSEMBLIES, INCLUDING SLEEVES AND INSTALLATION PROCEDURES SHALL
BE APPROVED BY THE BUILDING INSPECTOR PRIOR TO INSTALLATION.
INTERIOR FINISHES SHALL COMPLY WITH THE PROVISIONS OF CBC CHAPTER 8.
ALL DECORATIVE MATERIALS SHALL BE MAINTAINED IN A FLAME-RETARDANT CONDITION.
BUILDING NUMBERS SHALL BE EASILY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD
FRONTING THE PROPERTY.
THE CONSTRUCTION, REMODEL, OR DEMOLITION OF A BUILDING SHALL COMPLY WITH
THE REQUIREMENTS OF THE REQUIREMENTS OF NAPA COUNTY.
THESE PLANS AND ALL WORK SHALL COMPLY WITH THE CALIFORNIA BUILDING
STANDARDS CODE FOUND IN THE STATE OF CALIFORNIA TITLE 24 CCR, AS AMENDED AND
ADOPTED BY NAPA COUNTY.
CONTRACTOR SHALL THOROUGHLY COORDINATE ALL TRADES AS REQUIRED TO
COMPLETE ALL WORK INDICATED AND NECESSARY FOR THE PROJECT.
CONTRACTOR SHALL PROTECT EXISTING SITE FEATURES AND SHALL REPAIR OR REPLACE
ALL ITEMS DAMAGED DURING CONSTRUCTION.
THE CONTRACTOR SHALL ENFORCE ALL SAFETY MEASURES. THE CONTRACTOR SHALL
DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING AND
SHALL BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE AND FEDERAL
SAFETY AND HEALTH STANDARDS, LAWS AND REGULATION.
CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE
CONDITIONS DURING THE COURSE OF CONSTRUCTION, INCLUDING SAFETY OF ALL
PERSONS AND PROPERTY. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE
LIMITED TO NORMAL WORKING HOURS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY MONUMENTATION AND / OR
BENCHMARKS WHICH WILL BE DISTURBED OR DESTROYED BY CONSTRUCTION. SUCH
POINTS SHALL BE REFERENCED AND REPLACED WITH APPROPRIATE MONUMENTATION BY
A LICENSED LAND SURVEY OR REGISTERED CIVIL ENGINEER AS REQUIRED BY THE LAND
SURVEYOR'S ACT.
CONTRACTOR SHALL REPLACE IN KIND ANY TRAFFIC SENSORS DAMAGED DURING
CONSTRUCTION.
PENETRATION OF FIRE RESISTIVE WALLS, FLOOR - CEILING ASSEMBLIES AND ROOF -
CEILINGS SHALL BE PROTECTED AS REQUIRED IN CBC SECTION 714.
NO HAZARDOUS MATERIALS WILL BE USED OR STORED WITHIN THE BUILDING WHICH
EXCEED THE QUANTITIES SHOWN ON CBC TABLE 307.1(1).
WHEN SERVING MORE THAN 100 SPRINKLER HEADS, AUTOMATIC SPRINKLER SYSTEMS
SHALL BE SUPERVISED BY AN APPROVED CENTRAL PROGRAM OR REMOTE STATION
SERVICE OR SHALL BE PROVIDED WITH A LOCAL ALARM WHICH WILL GIVE AN AUDIBLE
SIGNAL AT A CONSTANTLY ATTENDED LOCATION.
WORK NOT SPECIFICALLY INDICATED OR SPECIFIED BUT WHICH IS REQUIRED FOR THE
COMPLETION OF THE WORK SHALL BE PROVIDED IN THE SAME MANNER AS SIMILAR
WORK WHICH IS REQUIRED OR SPECIFIED WITHOUT ADDITIONAL CHARGE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
PROJECT NUMBER:
SHEET TITLE:
NOT FOR
CONSTRUCTION
PROJECT:
SHEET NUMBER:
200 E STREET, SANTA ROSA, CA 95404
707.544.3920 | www.coargroup.com
DESCRIPTION: DATE:
100% SCHEMATIC
DESIGN
6/10/26
90% CDs 7/7/26
100%
CONSTRUCTION
DOCUMENTS
8/11/26
TITLE SHEET
260501
T-2
BELLA HOUSE KITCHEN
AND BATHROOM REHAB
NAPA COUNTY
1046 BELLA DR, NAPA, CA,
94558
T-1 TITLE SHEET
T-2 TITLE SHEET
A2.1 FIRST FLOOR PLAN & RCP
A5.1 INTERIOR ELEVATIONS
A6.1 ROOM FINISH SCHEDULE
A7.1 CABINET DETAILS
M101 MECHANICAL FIRST FLOOR PLANS
M601 MECHANICAL SCHEDULES, DETAILS AND LEGEND
P101 PLUMBING FIRST FLOOR PLANS
P601 PLUMBING SCHEDULES, DETAILS AND LEGEND
E2.1 FIRST FLOOR PLAN - LIGHTING
E3.1 FIRST FLOOR PLAN - ELECTRICAL
SYMBOLS
ABBREVIATIONS SHEET INDEX
# POUND or NUMBER
& AND
@ AT
L ANGLE
Ø DIAMETER or ROUND
ACOUS ACOUSTICAL
ACT ACOUSTICAL CEILING TILE
AD ACESS DOOR and FRAME
ALUM ALUMINUM
APP APPROXIMATE
ARCH ARCHITECTURAL
AS ACOUSTICAL SEALANT
ASB ACOUSTICAL SUSPENDED BAFFLES
B BRICK
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
CC COLUMN COVER
CFB CEMENT FIBER BOARD SIDING
CJ CONTROL JOINT
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CNC CONCRETE
CONT CONTINUOUS
CP CEMENT PLASTER
CPT CARPET
CW CURTAIN WALL
CWP COMPOSITE METAL WALL PANEL
DBL DOUBLE
DEFS DIRECT-APPLIED EXTERIOR FINISH SYSTEM
DET DETAIL
DIA DIAMETER
DIM or
DIMS
DIMENSION or DIMENSIONS
DN DOWN
DWG DRAWING
DWR DRAWER
(E) EXISTING
EA EACH
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
ELEC ELECTRICAL
ELEV ELEVATOR OR ELEVATION
EQ EQUAL
EXP EXPOSED STRUCTURE
EXT EXTERIOR
FAB FABRIC
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FFE FINISH FLOOR ELEVATION
FHC FIRE HOSE CABINET
FL FLOOR
FP FLAG POLE
FRP FIBERGLASS REINFORCED PANEL
FS FIRESTOP SYSTEM
FT FOOT or FEET
FTG FOOTING
GA GAUGE
GALV GALVANIZED
GB GYPSUM BOARD
GBT GYPSUM BOARD TRIM
GF GLAZING FILM
GFRC GLASS FIBER REINFORCED CONCRETE
GFRG GLASS FIBER REINFORCED GYPSUM
GL GLAZING
GRT GROUT
H HEIGHT
HB HOSE BIBB
HM HOLLOW METAL
HORIZ HORIZONTAL
INSUL INSULATION
INT INTERIOR
JS JOINT SEALANT
KB KNOX BOX
L LOCKER TYPE AND COLOR
LAV LAVATORY
LD LOADING DOCK EQUIPMENT
LF LIGHT FIXTURE
LV LOUVER
LVT LUXURY VINYL TILE
M.O. MASONRY OPENING
MAX MAXIMUM
MC METAL COPING
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MRP METAL ROOF PANEL
MTL METAL
MWP METAL WALL PANEL
(N) NEW
N.I.C. NOT IN CONTRACT
N.T.S. NOT TO SCALE
O.C. ON CENTER
OHD OVERHEAD DOOR
OP OPERABLE PANEL PARTITIOIN
P PAINT
PL PLASTIC LAMINATE
PLY PLYWOOD
PS PROJECTION SCREEN
PVC POLYVINYL CHLORIDE MEMBRANE ROOFING
QT QUARTZ
R.O. ROUGH OPENING
RAD RADIUS
REF REFERENCE
REINF REINFORCED
REQ REQUIRED
RM ROOM
RMT RUBBER MAT
RP ROOF PAVERS
S STUCCO
SCHED SCHEDULE
SF SQUARE FEET
SFRM SPRAYED FIRE-RESISTANT MATERIAL
SFT STOREFRONT
SIM SIMILAR
SJ SEISMIC JOINT
SM SHEET METAL
SPEC SPECIFICATION
SQ SQUARE
SS STAINLESS STEEL
SSU SOLID SURFACE
ST STAIN
STA STATION
STD STANDARD
STL STEEL
STN STONE
STOR STORAGE
STRUC STRUCTURAL
SUSP SUSPENDED
SYM SYMMETRICAL
T TILE
T&G TONGUE AND GROOVE
T.O. TOP OF
T.O.C. TOP OF CONCRETE
T.O.F. TOP OF FRAMING
T.O.M. TOP OF MASONRY
T.O.P. TOP OF PARAPET
T.O.S. TOP OF SHEATHING
T.V. TELEVISION
TA TOILET ACCESSORIES
TC TOILET COMPARTMENTS
TEL TELEPHONE
TG TEMPERED GLASS
TPO THERMOPLASTIC ROOF MEMBRANE
TS TRANSITION STRIP
TYP. TYPICAL
U.O.N. UNLESS OTHERWISE NOTED
V.I.F. VERIFY IN FIELD
V.T.R. VENT THRU ROOF
VERT VERTICAL
VT VINYL TILE
W/ WITH
W/O WITHOUT
WB WALL BASE
WC WATER CLOSET
WCR WALL COVERING
WD WOOD
WF WOOD FLOORING
WM WALK-OFF MAT
WPJ WEAKENED PLANE JOINT
GENERAL NOTES FIRE NOTES
W D
LIVING ROOM
BEDROOM 2
BEDROOM 3
BEDROOM 4
BEDROOM 5
BEDROOM 1
BEDROOM 7
BEDROOM 6
LIVING ROOM
KITCHEN
VESTIBULE
A5.1
A1 A5.1
B1
A5.1
D1
A5.1
C1
BLUE RESTROOM
LAUNDRY
RED RESTROOM
UTILITY
ENTRY HALL
HALLWAY 1
WHITE RESTROOM
B1
A5.1
TYP.
02 05 00.B1
ENTRY HALL
VESTIBULE
BEDROOM 5
HALLWAY 1
BEDROOM 4
BEDROOM 3 LIVING ROOM
LAUNDRY
UTILITY
RED RESTROOM
BEDROOM 6
BEDROOM 7BEDROOM 1
WHITE RESTROOM
LIVING ROOM
KITCHEN
BLUE RESTROOM
BEDROOM 2
26 01 00.A4
26 01 00.A5
23 31 00.A5
23 31 00.A6
26 01 00.A4
26 01 00.A5
23 31 00.A5
26 01 00.A4
26 01 00.A4
26 01 00.A5
23 31 00.A5
EXISTING CEILING MOUNTED LIGHT FIXTURE TO REMAIN
EXISTING CEILING MOUNTED LIGHT FIXTURE TO REMAIN
EXISTING CEILING MOUNTED LIGHT FIXTURE TO REMAIN
1. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS ON
SITE PRIOR TO COMMENCING WORK
2. ALL PLUMBING AND ELECTRICAL FIXTURES TO BE REPLACED IN EXISTING
LOCATION.
3. SEE INTERIOR ELEVATIONS FOR ALL RESTROOM ACCESSORY MOUNTING
HEIGHTS. SEE SPECIFICATIONS FOR ADDITIONAL ACCESSORY INFORMATION
4. ALL FLOORING TRANSITIONS TO OCCUR AT THE CENTERLINE OF THE DOOR
U.N.O. AND MEET ALL GUIDELINES FOR ACCESSIBILITY
5. ALL FINISHES TO CONTINUE UNDER FURNITURE AND EQUIPMENT U.N.O.
6. SEE FINISH LEGEND ON A6.1 FOR ADDITIONAL INFORMATION ON ALL
SCHEDULED MATERIALS
7. FOR ALL EXISTING EQUIPMENT TO REMAIN AND TO BE REUSED, CONTRACTOR
TO STORE AND PROTECT EXISTING EQUIPMENT DURING CONSTRUCTION.
CONTRACTOR TO REINSTALL AND RECONNECT EXISTING EQUIPMENT.
1. CONTRACTOR SHALL VERIFY ALL EXISTING CEILING CONDITIONS PRIOR
TO COMMENCING WORK
2. ALL EXISTING LIGHTING FIXTURES AND ELECTRICAL DEVICES TO BE
REMOVED AND REINSTALLED IN PLACE U.N.O.
3. CONTRACTOR TO VERIFY LOCATIONS OF ALL LIGHTING, MECHANICAL
AND ELECTRICAL DEVICES TO REMAIN AND PROTECT IN PLACE
4. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR LIGHT
FIXTURES, FIXTURE AND EQUIPMENT LOCATIONS AND ADDITIONAL
INFORMATION.
5. SEE SPECIFICATIONS AND CUT SHEET PACKAGE FOR ADDITIONAL
PRODUCT INFORMATION.
6. SEE INTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION.
LVT-1
PROJECT NUMBER:
SHEET TITLE:
NOT FOR
CONSTRUCTION
PROJECT:
SHEET NUMBER:
200 E STREET, SANTA ROSA, CA 95404
707.544.3920 | www.coargroup.com
DESCRIPTION: DATE:
100% SCHEMATIC
DESIGN
6/10/26
90% CDs 7/7/26
100%
CONSTRUCTION
DOCUMENTS
8/11/26
FIRST FLOOR
PLAN & RCP
260501
A2.1
BELLA HOUSE KITCHEN
AND BATHROOM REHAB
NAPA COUNTY
1046 BELLA DR, NAPA, CA,
94558
SCALE: 1/8" = 1'-0"A2.1
B1 FIRST FLOOR PLAN
SCALE: 1/8" = 1'-0"A2.1
D1 FIRST FLOOR REFLECTED CEILING PLAN
CONSTRUCTION NOTES
02 05 00.B1 EXISTING LIGHTING FIXTURE TO REMAIN, REPLACE BULB WITH AN LED
BULB, SEE ELECTRICAL DRAWINGS OTHERWISE
23 31 00.A5 RECESSED CEILING MOUNTED EXHAUST FAN WITH LIGHT (EQID 23-01), SEE
MECHANICAL DRAWINGS
23 31 00.A6 RANGE HOOD EXHAUST DUCTING, SEE MECHANICAL DRAWINGS
26 01 00.A4 CEILING MOUNTED DOWN LIGHT (EQID 26-03), SEE ELECTRICAL DRAWINGS
26 01 00.A5 24" WALL MOUNTED LIGHT FIXTURE (EQID 26-02), SEE ELECTRICAL
DRAWINGS
LEGEND
FLOOR PLAN NOTES
REFLECTED CEILING PLAN NOTES
LEGEND
A1
A5.1
A6.1
A6.1
22 40 00.F8
22 40 00.F9
11 30 13.D3
11 30 13.D4
11 30 13.D5
B1
A5.1
A6.1
10 28 00.D6
10 28 00.D7
10 28 00.D10
22 40 00.F6
22 40 00.F5
10 28 00.D8
22 40 00.F2
22 40 00.A4
22 40 00.F7
C1
A5.1 12 10
A6.1
10 28 00.D6
10 28 00.D7
10 28 00.D8
10 28 00.D9
10 28 00.D10
22 40 00.F5
22 40 00.F3
22 40 00.F4
22 40 00.A4
22 40 00.F2
2'
0"
1'
0"
3'
2'-0"2'-6"2'-0"FILLER
A7.1
A4
A7.1
B4
A7.1
C1
PT
SSU
PL
PL
ENTRY HALL
BEYOND
11 30 13.D4
2' -6
1' -9
3'
-2
2' -1
0"
FILLER 1'-9" 3'-0" 3'-0" 1'-9" FILLER
A7.1
B2
A7.1
B1
PL
SSU
09 72 00.D1
3'
1'
0"
2'
0"
V.I.F.3'-0"
3'-0" 3'-0" 2'-0" 2'-0" 3'-0" 3" FILLER
A7.1
C1
A7.1
A4
A7.1
A2
A7.1
A3
PT
PL
PL
SSU
LIVING ROOM
BEYOND
TYP.
B
11 30 13.D6
FILLER 1' - 9"
3'
1'
0"
2'
0"
A7.1
A4
A7.1
A1
PT
PL
SSU
PL
SSU
PT
FINISHED
3'-3" TYP.
B
2' - 10" 2' - 0" 4' - 0"
4'
"6'
PT
SSU
6'
2' -1
0"
2' - 2"
FILLER 1'-0" 2'-0" 1'-0"
A7.1
D1
A7.1
D2
PL
PT
SSU
SSU
3'-3"
PL
10 28 00.D5
SSU
3'
EQEQ
PT
PL
4'
3' - 0" 4' - 6"
SSU
PT
TYP.
B
SSU
6'
2' -3
2' -1
0"
A7.1
D3
3'-2"
PT
SSU
SSU
1' - 6"11"
3'
2'
10 28 00.D4
FILLER2'-0"
7' -9
A7.1
B3
PT
SSU
PL
2' - 2" 8"
4'
"6'
3'
4' - 0"
SSU
D1
A5.1
D1
A5.1
A6.1
10 28 00.D6
10 28 00.D7
22 40 00.A4
22 40 00.F2
22 40 00.F3
22 40 00.F4
22 40 00.F5 10 28 00.D8
PT
B
3' - 0"
4'
PT
TYP.
B
SSU
4'
1' - 10" 1' - 2"
2'-0"FILLER
A7.1
A3
PT
SSU
PL
SSU
PL
3'-0"
10 28 00.D3
B
SSU
SSU
PT
6'
2' - 1 3/4"
4'
2' - 6"
3'-0"
SSU
SSU
PROJECT NUMBER:
SHEET TITLE:
NOT FOR
CONSTRUCTION
PROJECT:
SHEET NUMBER:
200 E STREET, SANTA ROSA, CA 95404
707.544.3920 | www.coargroup.com
DESCRIPTION: DATE:
100% SCHEMATIC
DESIGN
6/10/26
90% CDs 7/7/26
100%
CONSTRUCTION
DOCUMENTS
8/11/26
INTERIOR
ELEVATIONS
260501
A5.1
BELLA HOUSE KITCHEN
AND BATHROOM REHAB
NAPA COUNTY
1046 BELLA DR, NAPA, CA,
94558
CONSTRUCTION NOTES
09 72 00.D1 1/2" THICK CORK BOARD APPLIED TO WALL (EQID 10-05), PAINTED PT-1 -
SEE FINISH LEGEND
10 28 00.D3 24" x 36" FRAMED MIRROR - SEE D4/A7.1
10 28 00.D4 30" x 36" FRAMED MIRROR - SEE D4/A7.1
10 28 00.D5 48" x 36" FRAMED MIRROR - SEE D4/A7.1
10 28 00.D6 TOWEL BAR (EQID 10-04)
10 28 00.D7 18" VERTICAL GRAB BAR (EQID 10-01)
10 28 00.D8 TOILET PAPER DISPENSER (EQID 10-03)
10 28 00.D9 24" GRAB BAR (EQID 10-01)
10 28 00.D10 36" GRAB BAR (EQID 10-01)
11 30 13.D3 (E) RANGE TO REMAIN - PROTECT IN PLACE
11 30 13.D4 (E) REFRIGERATOR TO REMAIN - PROTECT IN PLACE
11 30 13.D5 RANGE HOOD MICROWAVE COMBO (EQID 11-01), S.E.D. & S.M.D.
OTHERWISE
11 30 13.D6 RELOCATED (E) DISHWASHER, CONTRACTOR TO RELOCATE POWER AND
WET UTILITY CONNECTIONS TO ACCOMMODATE NEW LOCATION
22 40 00.A4 BATHROOM SINK (EQID 22-06), S.P.D.
22 40 00.F2 BATHROOM FAUCET (EQID 22-07), S.P.D.
22 40 00.F3 SHOWER TRIM KIT (EQID 22-03), S.P.D.
22 40 00.F4 SHOWER DRAIN (EQID 22-05), S.P.D.
22 40 00.F5 TOILET (EQID 22-01), S.P.D.
22 40 00.F6 BATH & SHOWER TRIM KIT (EQID 22-02), S.P.D.
22 40 00.F7 BATHTUB (EQID 22-04), S.P.D.
22 40 00.F8 KITCHEN FAUCET (EQID 22-09), S.P.D.
22 40 00.F9 KITCHEN SINK (EQID 22-08), S.P.D.
SCALE: 1/4" = 1'-0"A5.1
A1 ENLARGED PLAN - KITCHEN
SCALE: 1/4" = 1'-0"A5.1
B1 ENLARGED PLAN - BATHROOM 1 - BLUE
SCALE: 1/4" = 1'-0"A5.1
C1 ENLARGED PLAN - BATHROOM 2 - WHITE
SCALE: 1/4" = 1'-0"A5.1
D1 ENLARGED PLAN - BATHROOM 3 - RED
1 2
6 7 85
129 10 11
13 14 15 16 17
WATERPROOFING
RESILIENT (LUXURY VINYL
TILE) FLOORING
EXISTING CARPET
FLOOR TRANSITION STRIP
BETWEEN CARPET AND LVT
(E) SUBFLOOR
RO
DOOR FRAME BEYOND
RESILIENT (LUXURY VINYL TILE)
FLOORING
DOOR AS SCHEDULED
EXISTING CARPET
FLOOR TRANSITION STRIP
BETWEEN CARPET AND LVT
(E) SUBFLOOR
PROJECT NUMBER:
SHEET TITLE:
NOT FOR
CONSTRUCTION
PROJECT:
SHEET NUMBER:
200 E STREET, SANTA ROSA, CA 95404
707.544.3920 | www.coargroup.com
DESCRIPTION: DATE:
100% SCHEMATIC
DESIGN
6/10/26
90% CDs 7/7/26
100%
CONSTRUCTION
DOCUMENTS
8/11/26
ROOM FINISH
SCHEDULE
260501
A6.1
BELLA HOUSE KITCHEN
AND BATHROOM REHAB
NAPA COUNTY
1046 BELLA DR, NAPA, CA,
94558
ROOM FINISH SCHEDULE
ROOMS FLOOR BASE WALLS CEILING CASEWORK
REMARKSDESCRIPTION MATERIAL MATERIAL
NORTH EAST SOUTH WEST
MATERIAL HEIGHT COUNTERTOP CABINETMATERIAL MATERIAL MATERIAL MATERIAL
KITCHEN LVT-1 B-1 PT-1 PT-1 PT-1 PT-1 GYP., PT-2 8' - 0" SSU-1 PL-1 SEE INTERIOR ELEVATIONS AND FINISH SCHEDULE
BLUE RESTROOM LVT-1 B-1 PT-1 PT-1 PT-1 PT-1 GYP., PT-2 8' - 0" SSU-1 PL-1 SEE INTERIOR ELEVATIONS AND FINISH SCHEDULE
RED RESTROOM LVT-1 B-1 PT-1 PT-1 PT-1 PT-1 GYP., PT-2 8' - 0" SSU-1 PL-1 SEE INTERIOR ELEVATIONS AND FINISH SCHEDULE
WHITE RESTROOM LVT-1 B-1 PT-1 PT-1 PT-1 PT-1 GYP., PT-2 8' - 0" SSU-1 - SEE INTERIOR ELEVATIONS AND FINISH SCHEDULE
MATERIAL LEGEND
ABRV. DESCRIPTION
ACT ACOUSTIC CEILING TILE
ASB ACOUSTICAL SUSPENDED BAFFLES
B BRICK
CC COLUMN COVER
CFB CEMENT FIBER BOARD SIDING
CMU CONCRETE MASONRY UNIT
CNC CONCRETE
CP CORNER PROTECTION
CPT CARPET
CT CERAMIC/PORCELAIN TILE
CW CURTAIN WALL
CWP COMPOSITE METAL WALL PANEL
DEFS DIRECT-APPLIED EXTERIOR FINISH SYSTEM
EIFS EXTERIOR INSULATION & FINISH SYSTEM
EXP EXPOSED STRUCTURE
FAB FABRIC
FRP FIBERGLASS REINFORCED PLASTIC
GB-1 GYPSUM WALL BOARD, 5/8" UON
GB-2 GYPSUM WALL BOARD, SOUND ABSORBENT
GB-3 GYPSUM WALL BOARD, FIRE RESISTANT (5/8") TYPE-X
GB-4 GYPSUM WALL BOARD, WATER RESISTANT (5/8")
GBT GYPSUM BOARD TRIM
GF GLAZING FILM
GFRC GLASS FIBER REINFORCED CEMENT
GFRG GLASS FIBER REINFORCED GYPSUM
GL GLAZING
GRT GROUT
JS JOINT SEALANT
L LOCKER
LV LOUVERS
LVT LUXURY VINYL TILE
MC METAL COPING
MRP METAL ROOF PANEL
MTL METAL FINISH
MWP METAL WALL PANEL
OHD OVERHEAD DOOR
OP OPERABLE PANEL PARTITION
P PAINT
PL PLASTIC LAMINATE
PLY PLYWOOD, PAINTED, 1/2" UON
PVC POLYVINYL CHLORIDE MEMBRANE ROOFING
QTZ QUARTZ
RMT RUBBER MAT
RP ROOF PAVERS
S STUCCO - PORTLAND CEMENT PLASTER
SFT STOREFRONT
SS STAINLESS STEEL
SSU SOLID SURFACE
ST STAIN
STN STONE
TC TOILET COMPARTMENTS
TPO THERMOPLASTIC MEMBRANE ROOFING
VT VINYL TILE
WB WALL BASE
WCR WALL COVERING
WD WOOD
WF WOOD FLOORING
WM WALK-OFF MAT
WT WINDOW TREATMENT
FINISH SCHEDULE
MATERIAL TYPE
DESCRIPTION
COMMENTSNAME MANUFACTURER STYLE COLOR
B 1 FLOOR BASE TARKETT / JOHNSONITE MONUMENT MW-XX-S4 (4") 08 ICICLE STANDARD BASE
LVT 1 LUXURY VINYL TILE TILEBAR HEIGHTS - LOOSE LAY 9"x60" COUNTRYSIDE KITCHEN, RESTROOMS
PL 1 PLASTIC LAMINATE WILSONART - 8242-33 JUBILEE OAK CASEWORK
PT 1 PAINT PPG EGGSHELL CANDLELIT BEIGE (1207-1) FIELD COLOR, SEE NAPA APPROVED COLORS
PT 2 PAINT PPG SEMI-GLOSS DELICATE WHITE (1001-1) INTERIOR DOORS & CASING, SEE NAPA
APPROVED COLORS
SSU 1 SOLID SURFACE WILSONART STANDARD (1/2") 9208CS WHITE STONE COUNTERTOP & BACKSPLASH
SSU 2 SOLID SURFACE AVONITE WET WALL (1/4") 9117 KOKOURA SHOWER WALLS
SSU 3 SOLID SURFACE AVONITE STANDARD (1/2") 9117 KOKOURA SHOWER PANS
DOOR SCHEDULE
DOOR FRAME DETAIL
REMARKSMARK WIDTH HEIGHT DEPTH MATERIAL FINISH MATERIAL FINISH THRESHOLD
101 3' - 0" 7' - 0" 0' - 1 3/4" WD P-2 WD P-2 1/A6.1 EXISTING DOOR AND DOOR FRAME TO REMAIN AND RECEIVE NEW PAINT, SEE FINISH SCHEDULE
102 3' - 0" 7' - 0" 0' - 1 3/4" WD P-2 WD P-2 1/A6.1 EXISTING DOOR AND DOOR FRAME TO REMAIN AND RECEIVE NEW PAINT, SEE FINISH SCHEDULE
103 3' - 0" 7' - 0" 0' - 1 3/4" WD P-2 WD P-2 1/A6.1 EXISTING DOOR AND DOOR FRAME TO REMAIN AND RECEIVE NEW PAINT, SEE FINISH SCHEDULE
SCALE: 6" = 1'-0"A6.1
2 TRANSITION AT LVT TO CARPET
SCALE: 3" = 1'-0"A6.1
1 DOOR & FRAME - INTERIOR THRESHOLD
4"
1 1/2"
1/
2"
8"
COUNTERTOP, SEE FINISH SCHEDULE
EASED EDGE, TYP.
FULL EXTENSION DRAWER SLIDES,
PROVIDE BRACING AS REQUIRED
PULL, ALL PULLS SHALL ALIGN, TYP.
PLASTIC LAMINATE CASEWORK, SEE
FINISH SCHEDULE
PLASTIC LAMINATE BASE
U.O.N. ON ENLARGED PLANS
1'-6"
BACKSPLASH WHERE OCCURS, SEE
FINISH SCHEDULE AND ELEVATIONS
3"
2' -1
0"
WHITE MELAMINE FINISH, TYP.
8"
4"
1 1/2"
1/
2"
COUNTERTOP, SEE FINISH SCHEDULE
EASED EDGE, TYP.
FULL EXTENSION DRAWER SLIDES,
PROVIDE BRACING AS REQUIRED
PULL, ALL PULLS SHALL ALIGN, TYP.
PLASTIC LAMINATE CASEWORK, SEE
FINISH SCHEDULE
PLASTIC LAMINATE BASE
U.O.N. ON ENLARGED PLANS
2'-0"
BACKSPLASH WHERE OCCURS, SEE
FINISH SCHEDULE AND ELEVATIONS
2' -1
0"
WHITE MELAMINE FINISH, TYP.
6" 6"
3"
U .O
.N . O
N
IN
T E
R
IO
R E
LE
V
A T
IO
N
S
2' -1
0"
4"
1 1/2"
1/
2"
COUNTERTOP, SEE FINISH SCHEDULE
EASED EDGE, TYP.
PLASTIC LAMINATE BASE
U.O.N. ON ENLARGED PLANS
2'-0"
ADJUSTABLE SHELF STANDARDS &
SUPPORTS
3/4" MELAMINE FACED PLYWOOD
SHELVING
WHITE MELAMINE FINISH, TYP.
BACKSPLASH WHERE OCCURS, SEE
FINISH SCHEDULE AND ELEVATIONS
3"
PLASTIC LAMINATE CASEWORK, SEE
FINISH SCHEDULE
PULL, ALL PULLS SHALL ALIGN, TYP.
U .O
.N . O
N
IN
T E
R
IO
R E
LE
V
A T
IO
N
S
2' -1
0"
U.O.N. ON ENLARGED PLANS
2'-0"
1/
2"
6"
PLASTIC LAMINATE CASEWORK, SEE
FINISH SCHEDULE
WHITE MELAMINE FINISH, TYP.
PULL, ALL PULLS SHALL ALIGN, TYP.
BACKSPLASH WHERE OCCURS, SEE
FINISH SCHEDULE AND ELEVATIONS
COUNTERTOP, SEE FINISH SCHEDULE
EASED EDGE, TYP.
PLASTIC LAMINATE BASE
4"
3"
DRAWER PANEL
1 1/2"
V A
R
IE
S , S
E E
IN
T
E R
IO
R
E
LE
V A
T
IO
N S
3"
SCRIBE TO CEILING WHERE OCCURS
ADJUSTABLE SHELF STANDARDS &
SUPPORTS
ADJUSTABLE WOOD SHELF, TYP.
WHITE MELAMINE FINISH, TYP.
PULL, ALL PULLS SHALL ALIGN, TYP.
PLASTIC LAMINATE CASEWORK, SEE
FINISH SCHEDULE
1'-3"
3"
3"
SCRIBE TO CEILING WHERE OCCURS
PULL, ALL PULLS SHALL ALIGN, TYP.
PLASTIC LAMINATE CASEWORK, SEE
FINISH SCHEDULE
1'-3"
3"
WHITE MELAMINE FINISH, TYP.
2' -1
0"
6"
2'-0"
1 1/2"
1/
2"
EASED EDGE, TYP.
COUNTERTOP, SEE FINISH SCHEDULE
FULL EXTENSION DRAWER SLIDES,
PROVIDE BRACING AS REQUIRED
PLASTIC LAMINATE BASE
PULL, ALL PULLS SHALL ALIGN, TYP.
ADJUSTABLE WOOD SHELF, TYP.
3"
4"
PLASTIC LAMINATE CASEWORK, SEE
FINISH SCHEDULE
ADJUSTABLE SHELF STANDARDS &
SUPPORTS
WHITE MELAMINE FINISH, TYP.
3' -2
1'
-9
CORK BOARD APPLIED TO WALL AND
PAINTED P-1, SEE FINISH LEGEND
3"
2'-2"
PULL, ALL PULLS SHALL ALIGN, TYP.
ADJUSTABLE WOOD SHELF, TYP.
WHITE MELAMINE FINISH, TYP.
PLASTIC LAMINATE CASEWORK, SEE
FINISH SCHEDULE
3"
WHITE MELAMINE FINISH, TYP.
4"
ADJUSTABLE SHELF STANDARDS &
SUPPORTS
PLASTIC LAMINATE BASE
SCRIBE TO CEILING WHERE OCCURS
1' -2
3"
SCRIBE TO CEILING WHERE OCCURS
WHITE MELAMINE FINISH, TYP.
PULL, ALL PULLS SHALL ALIGN, TYP.
PLASTIC LAMINATE CASEWORK, SEE
FINISH SCHEDULE
1'-3"
3"
MICROWAVE HOOD EXHAUST DUCT AS
OCCURS, S.M.D. - SEE MECHANICAL
MICROWAVE HOOD, S.M.D. - SEE
SPECIFICATIONS
2' -1
0"
6"
2'-0"
1 1/2"
1/
2"
EASED EDGE, TYP.
COUNTERTOP, SEE FINISH SCHEDULE
BACKSPLASH WHERE OCCURS, SEE
FINISH SCHEDULE AND ELEVATIONS
FULL EXTENSION DRAWER SLIDES,
PROVIDE BRACING AS REQUIRED
PLASTIC LAMINATE BASE
PULL, ALL PULLS SHALL ALIGN, TYP.
ADJUSTABLE WOOD SHELF, TYP.
3"
4"
PLASTIC LAMINATE CASEWORK, SEE
FINISH SCHEDULE
ADJUSTABLE SHELF STANDARDS &
SUPPORTS
WHITE MELAMINE FINISH, TYP.
2' -1
0"
U.O.N. ON ENLARGED PLANS
1'-8"
1/
2"
6"
PLASTIC LAMINATE CASEWORK, SEE
FINISH SCHEDULE
WHITE MELAMINE FINISH, TYP.
PULL, ALL PULLS SHALL ALIGN, TYP.
BACKSPLASH WHERE OCCURS, SEE
FINISH SCHEDULE AND ELEVATIONS
COUNTERTOP, SEE FINISH SCHEDULE
EASED EDGE, TYP.
PLASTIC LAMINATE BASE
4"
3"
DRAWER PANEL
1 1/2"
1/
2"
EASED EDGE, TYP.
SOLID SURFACE COUNTERTOP W/
IN-WALL STEEL SUPPORTS - SCRIBE TO
WALL
KNEE AND TOE CLEARANCE
M
IN
9" M
IN
1"
6" MIN
8" MIN
11" MIN
2'-0"
5"
2' -1
0"
SOLID SURFACE APRON
BATHROOM SINK (EQID 22-06), S.P.D.
BACKSPLASH WHERE OCCURS, SEE
FINISH SCHEDULE AND ELEVATIONS
E Q
E Q
2'-2"
ADJUSTABLE WOOD SHELF, TYP.
WHITE MELAMINE FINISH, TYP.
PLASTIC LAMINATE CASEWORK, SEE
FINISH SCHEDULE
3"
WHITE MELAMINE FINISH, TYP.
4"
ADJUSTABLE SHELF STANDARDS &
SUPPORTS
PLASTIC LAMINATE BASE3"
SCRIBE TO CEILING WHERE OCCURS
TEMPERED GLASS
MIRROR
MIRROR FRAME,
PLASTIC LAMINATE
ALL EXPOSED SIDES
2X BLOCKING
WALL PER PLAN
ALUMINUM MOUNTING BRACKET PROJECT NUMBER:
SHEET TITLE:
NOT FOR
CONSTRUCTION
PROJECT:
SHEET NUMBER:
200 E STREET, SANTA ROSA, CA 95404
707.544.3920 | www.coargroup.com
DESCRIPTION: DATE:
100% SCHEMATIC
DESIGN
6/10/26
90% CDs 7/7/26
100%
CONSTRUCTION
DOCUMENTS
8/11/26
CABINET DETAILS
260501
A7.1
BELLA HOUSE KITCHEN
AND BATHROOM REHAB
NAPA COUNTY
1046 BELLA DR, NAPA, CA,
94558
SCALE: 1" = 1'-0"A7.1
D1 3-DRW BASE CABINET
SCALE: 1" = 1'-0"A7.1
A2 4-DRW BASE CABINET
SCALE: 1" = 1'-0"A7.1
A1 BASE CABINET
SCALE: 1" = 1'-0"A7.1
A3 SINK BASE CABINET
SCALE: 1" = 1'-0"A7.1
A4 UPPER CABINET
SCALE: 1" = 1'-0"A7.1
B1 CABINET AND SHELF
SCALE: 1" = 1'-0"A7.1
B2 TALL CABINET
SCALE: 1" = 1'-0"A7.1
B4 UPPER CABINET
SCALE: 1" = 1'-0"A7.1
C1 BASE CABINET
SCALE: 1" = 1'-0"A7.1
D2 SINK BASE CABINET 2
SCALE: 1" = 1'-0"A7.1
D3 COUNTERTOP WITH LAVATORY
SCALE: 1" = 1'-0"A7.1
B3 TALL CABINET
SCALE: 1 1/2" = 1'-0"A7.1
D4 MIRROR WALL MOUNTING
W D
LIVING ROOM
BEDROOM 2
BEDROOM 3
BEDROOM 4
BEDROOM 5
BEDROOM 1 BEDROOM 7
BEDROOM 8
BEDROOM 6
KITCHEN
VESTIBULE
BATH 1
LAUNDRY
BATH 3
UTILITY
ENTRY
HALLWAY 1
BATH 2
PROJECT NUMBER:
SHEET TITLE:
PROJECT:
SHEET NUMBER:
200 E STREET, SANTA ROSA, CA 95404
707.544.3920 | www.coargroup.com
DESCRIPTION: DATE:
100% SCHEMATIC
DESIGN
6/10/26
260501
NAPA COUNTY BELLA
REHAB
NAPA COUNTY
1046 BELLA DR, NAPA, CA,
94558
100% CONSTRUCTION
DOCUMENTS
6/26/26
MECHANICAL
FIRST FLOOR
PLANS
M101
SCALE: 1/4" = 1'-0"M101 FIRST FLOOR MECHANICAL PLAN
100% SCHEMATIC
DESIGN
6/10/26
90% CDs 7/7/26
100%
CONSTRUCTION
DOCUMENTS
8/11/26
PROJECT NUMBER:
SHEET TITLE:
PROJECT:
SHEET NUMBER:
200 E STREET, SANTA ROSA, CA 95404
707.544.3920 | www.coargroup.com
DESCRIPTION: DATE:
100% SCHEMATIC
DESIGN
6/10/26
260501
NAPA COUNTY BELLA
REHAB
NAPA COUNTY
1046 BELLA DR, NAPA, CA,
94558
100% CONSTRUCTION
DOCUMENTS
6/26/26
MECHANICAL
SCHEDULES,
DETAILS AND
LEGEND
M601
100% SCHEMATIC
DESIGN
6/10/26
90% CDs 7/7/26
100%
CONSTRUCTION
BEDROOM 2
BEDROOM 3
BEDROOM 4
BEDROOM 5
BEDROOM 1 BEDROOM 7
BEDROOM 8
BEDROOM 6
KITCHEN
VESTIBULE
BATH 1
LAUNDRY
BATH 3
UTILITY
ENTRY
HALLWAY 1
BATH 2
PROJECT NUMBER:
SHEET TITLE:
PROJECT:
SHEET NUMBER:
200 E STREET, SANTA ROSA, CA 95404
707.544.3920 | www.coargroup.com
DESCRIPTION: DATE:
100% SCHEMATIC
DESIGN
6/10/26
260501
NAPA COUNTY BELLA
REHAB
NAPA COUNTY
1046 BELLA DR, NAPA, CA,
94558
100% CONSTRUCTION
DOCUMENTS
6/26/26
PLUMBING
FIRST FLOOR
PLANS
P101
SCALE: 1/4" = 1'-0"P101 FIRST FLOOR PLUMBING PLAN
100% SCHEMATIC
DESIGN
6/10/26
90% CDs 7/7/26
100%
CONSTRUCTION
PROJECT NUMBER:
SHEET TITLE:
PROJECT:
SHEET NUMBER:
200 E STREET, SANTA ROSA, CA 95404
707.544.3920 | www.coargroup.com
DESCRIPTION: DATE:
100% SCHEMATIC
DESIGN
6/10/26
260501
NAPA COUNTY BELLA
REHAB
NAPA COUNTY
1046 BELLA DR, NAPA, CA,
94558
100% CONSTRUCTION
DOCUMENTS
6/26/26
PLUMBING
SCHEDULES,
DETAILS AND
LEGEND
P601
100% SCHEMATIC
DESIGN
6/10/26
90% CDs 7/7/26
100%
CONSTRUCTION
TYP.
02 05 00.B1
ENTRY HALL
VESTIBULEBEDROOM 5
HALLWAY 1
BEDROOM 4
BEDROOM 3 BEDROOM 6
LAUNDRY
UTILITY
BATHROOM 3
BEDROOM 8
BEDROOM 7BEDROOM 1
BATHROOM 2LIVING ROOM
KITCHEN
BATHROOM 1
BEDROOM 2
1 2 TYPICAL
NUMBERED SHEET NOTES
RE-LAMP ALL (E) LIGHT FIXTURES IN THE RESIDENCE WITH (N)
LED EQUIVALENT LAMPS; 2700K COLOR TEMPERATURE, 80CRI,
DIMMABLE. FIELD VERIFY ALL (E) WATTAGES AND PROVIDE LED
WITH MATCHING LUMEN OUTPUT.
ALL (E) CONTROLS TO REMAIN. NO RE-WIRING, EXCEPT AS
NOTED ON SHEET E3.1
PROJECT:
DESCRIPTION: DATE:
PROJECT NUMBER:
SHEET TITLE:
SHEET NUMBER:
200 E STREET, SANTA ROSA, CA 95404
619.698.9177 | www.coargroup.com
Exp. 6/27
RE
DN
ARBNELOC.J
RETEI P
RE
EN
IG
NE
LAN
OISSEFORP
DERETSI
GER
C
LIFOAF C
TRI
RN
AALE C I
ET
AT
S LE
No.E14738
O
NOT FOR
CONSTRUCTION
260501
NAPA COUNTY BELLA
REHAB
NAPA COUNTY
1046 BELLA DR, NAPA, CA,
94558
7/2/26BID SET
FIRST FLOOR
PLAN - LIGHTING
E2.11 E2.1
FIRST FLOOR PLAN - LIGHTING
1/4" = 1'-0"SCALE:
100% SCHEMATIC
DESIGN
6/10/26
90% CDs 7/7/26
100%
CONSTRUCTION
BEDROOM 2
BEDROOM 3
BEDROOM 4
BEDROOM 5
BEDROOM 1 BEDROOM 7
BEDROOM 8
BEDROOM 6
KITCHEN
VESTIBULE
BATHROOM 1
LAUNDRY
BATHROOM 3
UTILITY
ENTRY HALL
HALLWAY 1
BATHROOM 2
O S
OS
OS
(E) HOUSE PANEL 'A' 7
E-3 1
GFI
A-19
A-19
E-2 1
E-1 1
NUMBERED SHEET NOTES
FLUSH CEILING MOUNTED COMBINATION LIGHT / EXHAUST FAN
(BY MECHANICAL). CONNECT COMPLETE TO (E) EXHAUST / LIGHT
FAN CIRCUIT FOR BATHROOM, VIA NEW CONTROLS SHOWN. ALL
LIGHTS AND EXHAUST FAN IN ROOM TO BE SWITCHED IN
PARALLEL.
RANGE HOOD / MICROWAVE COMBINATION UNIT (BY OTHERS).
CONNECT COMPLETE TO NEW CIRCUIT AS SHOWN.
PROVIDE AND INSTALL (N) IR STYLE WALL SWITCH VACANCY
SENSOR (MANUAL-ON, AUTO-OFF WITH 20 MINUTE DELAY), TO
REPLACE (E) DUAL SWITCHES. PROVIDE (N) 2-GANG WALL PLATE
WITH 1-GANG OPENING FOR SINGLE SWITCH VACANCY SENSOR.
PROVIDE AND INSTALL (N) 24" LINEAR LED OVER-MIRROR LIGHT
FIXTURE TO REPLACE (E) FIXTURE; KOHLER MODEL CRUE
K-32631-SCLED. RECONNECT COMPLETE AS SHOWN, VIA NEW
CONTROLS.
PROVIDE AND INSTALL (N) 11" ROUND LED CEILING LIGHT
FIXTURE TO REPLACE (E) FIXTURE; JUNO MODEL SLIMFORM #JSF
11IN. RECONNECT COMPLETE AS SHOWN, VIA NEW CONTROLS.
PROVIDE AND INSTALL (N) DUAL 20A/1P BRANCH BREAKER IN (E)
SPACES 19 AND 20. NEW BREAKER TO MATCH (E) IN
MANUFACTURER AND TYPE.
PROVIDE AND INSTALL (N) RECEPTACLE FOR (N) MICROWAVE.
COORDINATE EXACT LOCATION WITH MICROWAVE EQUIPMENT,
PRIOR TO ROUGH-IN.
PROJECT:
DESCRIPTION: DATE:
PROJECT NUMBER:
SHEET TITLE:
SHEET NUMBER:
200 E STREET, SANTA ROSA, CA 95404
619.698.9177 | www.coargroup.com
Exp. 6/27
RE
DN
ARBNELOC.J
RETEI P
RE
EN
IG
NE
LAN
OISSEFORP
DERETSI
GER
C
LIFOAF C
TRI
RN
AALE C I
ET
AT
S LE
No.E14738
O
NOT FOR
CONSTRUCTION
260501
NAPA COUNTY BELLA
REHAB
NAPA COUNTY
1046 BELLA DR, NAPA, CA,
94558
7/2/26BID SET
FIRST FLOOR
PLAN -
ELECTRICAL
E3.11 E2.1
FIRST FLOOR PLAN - LIGHTING
1/4" = 1'-0"SCALE:
W D
LAUNDRY
W D
LAUNDRY
NOT USED
100% SCHEMATIC
DESIGN
6/10/26
90% CDs 7/7/26
100%
CONSTRUCTION
| GENERAL |
| T-1 - TITLE SHEET |
| T-2 - TITLE SHEET |
| ARCHITECTURAL |
| A2.1 - FIRST FLOOR PLAN & RCP |
| A5.1 - INTERIOR ELEVATIONS |
| A6.1 - ROOM FINISH SCHEDULE |
| A7.1 - CABINET DETAILS |
| MECHINICAL |
| M101 MECHANICAL FIRST FLOOR PLANS |
| M601 MECHANICAL SCHEDULES, DETAILS AND LEGEND |
| PLUMBING |
| P101 PLUMBING FIRST FLOOR PLANS |
| P601 PLUMBING SCHEDULES, DETAILS AND LEGEND |
| ELECTRICAL |
| E2.1 FIRST FLOOR PLAN - LIGHTING |
| E3.1 FIRST FLOOR PLAN - ELECTRICAL |