This is an architectural drawing file for the West Hartford Senior Center, a mixed-use facility located at 15 Starkel Road in West Hartford, Connecticut, prepared by Silver/Petrucelli + Associates Architects. The project combines an existing library (7,760 square feet) with a new senior center (7,040 square feet) for a total building area of 14,600 square feet on a single story with a maximum height of 47 feet 2 inches. The facility is classified as Use Group A3 (Assembly) construction type and includes detailed means of egress, occupancy load, and fire safety specifications. The design accommodates a total occupancy load of 463 persons with an exit capacity of 2,164 persons, exceeding code requirements. The building incorporates fire-rated walls, smoke barriers, mechanical areas, and accessibility features in compliance with applicable building codes.

The document presents comprehensive code compliance information including maximum floor area allowances per occupant (ranging from 7 square feet net for assembly areas to 300 square feet gross for mechanical areas), maximum exit travel distances of 200 feet per B.O.C.A. standards, and fire resistance ratings for various structural elements. The adjusted tabular building area of 37,500 square feet provides adequate allowance for the actual floor area of 14,600 square feet. Fire-rated assemblies include 2-hour ratings for exit enclosures and elevator shafts, with 1-hour ratings for exit access corridors and other separation assemblies. The design documentation demonstrates compliance with smoke barrier requirements and establishes appropriate compartmentalization for the mixed-use occupancy, supporting the facility's operational functionality for both library and senior center services.

View the file

Other files

Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Bishops Corner Library/Senior

PROPERTY UlIiE =©=

SET BACK UNE

SYMBOL LEGEND

AREA IM S.F.

OCC. LOAD

FACTOR

^z f6B

ACTUAL EGRESS

ooc or 0001^

MAX. ALLOWABLE

EGRESS OCC. OF DOOR

120-

ACCESSIBLE AREA OR EXIT

- ROOM OCCUPANCY LOAD

- EXIT CAPACITY

- ^ HOUR FIRE RATED WALL

- CEILIMG/WALLS RESIST

THE PASSAGE OF SMOKE

- MAXIMUM TRAVEL DISTANCE

- DIRECTION OF TRAVEL

D

Project Title:

WEST HARTFORD SENIOR CENTER

15 STARKEL ROAD

WEST HARTFORD, CONNECTICUT

SILVER / PETRUCELLI + ASSOCIATES

Architects

3190 Whitney Avenue, Hamden, CT 06518-2340

Tel. 203 230 9007 Fax. 203 230 8247 silverpetrucelli. com

Revision: Description: Date: Revised By:

D n

J D

MEANS OF EGRESS

MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT

USE

1. CLASSROOMS

2. SHOPS & VOCATIONAL

3. ASSEMBLY

WITHOUT FIXED SEATS

TABLES AND CHAIRS

4. LIBRARY

5. MECHANICAL AREAS

6. BUSINESS AREAS

FLOOR AREA IN S.F. PER OCCUPANT

20 S.F. WET

SO S.F. NET

7 S.F. hET

15 S.F. NET

SO S.F. NET

300 S.F. GROSS

100 S.F. QROSS

MAXIMUM LENGTM OF EXIT TRAVEL

1. B.O.C.A. TABLE 807 2QO FEET

2. LIFE SAFETY TABLE A-5.6.1 ISO FEET (MOST RESTBICTIVE GOVERNS)

SUBDIVISION OF BUILDING SPACE

1. LIFE SAFETY 11-3.7 SCHOOL BUILDINGS SHALL BE SUBDIVIDED

INTO COMPARTMENTS BY SMOKE BARRIERS WHEN THE MAXIMUM

AREA OF A COMPARTMENT EXCEEDS 30,000 S.F. OR

A DIMENSION GREATER THAN 300'

CODE INFORMATION

1. USE GROUP CLASSIFICATION

A3 - ASSEMBLY

CONSTRUCTION TYPE (401.0)

MINIMUM TYPE OF REQUIRED

ACTUAL TYPE PROVIDED: ^^ " A3 ASSEMBLY,

SB

3. BUILDING HEIGHT (501.0 - 503.0)

ALLOWABLE HEIGHT STORY/FEET AO - a aTORY eO'-O*

ACTUAL HEIGHT STORYAEET 1 STORY AT-Z'

STORIES ABOVE GRADE 1 STORY

BUILDING AREA (501.0 - 503.0)

GROSS BUILDING AREA: (PER FLOOR)

FIRST FLOOR EXISTING LIBRARY _

FIRST FLOOR SENIOR CENTER _

TOTAL = _

AREA TABULATION

7760 SQ. FT.

7,040 SQ. FT.

14.600 SQ.FT.

OPEN SPACE 2Qa!=6' 119'-ft'

NORTH EAST

646'-6' PERIMETER FT. OPEN PERIMETER

149'-a' 203'-6'

WEST SOUTH

6»46'-6'.

X PERIMETER - (OPEN PERIMETER / PERIMETER)

X TABULAR AREA INCREASE - 2x (X OPEN PERMETER lOOX 29X) tsox

100J4

- OX

+ ^50X

X INCREASE FOR FULL FIRE SUPPRESSION (TABLE 502.3) + 2007i

4SOX

X OF ALLOWABLE TABULAR AREA (TABLE 501)

X REDUCTION FOR HEIGHT (TABLE 501.•)

X INCREASE FOR OPEN PERIMETER (TABLE 502.2)

CONVERSION FACTOR (X FACTOR / 100)

TOTAL PERCENTAGE FACTOR

4.60

a. ADJUSTED TABULAR AREA (ACTUAL FIR. AREA / CONV. FACTOR

b. ALLOWABLE BUILDING AREA CONV. FACTOR X TAB. AREA .

(TAB. AREA PER. TABLE 501)

37.SOO

S.F.

ACTUAL FLOOR AREA.

(NCN SEPERATEO MIXED USE- MOST RESTRICTIVE USED ABOVE A3)

^^.gOQ S.F.

6. MIXED USE: (313.0)

(X) NON-SEPARATED USES

( ) SEPARATED USES

FIRST FLOOR

ACTUAL FLOOR AREA _A3_ USE= H^QO S.F.

FIRST FLOOR ^3 ASSEMBLY MOST RESTRICTIVE 1ST FL-OOR

ACTUAL AREA

ALLOWABLE AREA

LIBRARY

37,600

SENIOR CENTER

7.040 ^ .391S < 1 OK

37.600

OCCUPANCY LOAD (REFER TO PLAN)

DESIGN TOTAL FIRST FLOOR 463

TOTAL EXIT CAPACITY FIRST FLOOR 216-4

DESIGN TOTAL FOR BUILDING

TOTAL EXIT CAPACITY FOR BUILDING.

b. FIRE WALLS AND PARTY WALLS

c. FIRE SEPARATION ASSEMBLIES

FIRE RESISTANT RATING OF STRUCTURE ELEMENTS

a. EXTERIOR WALLS: LOAD BEARING 0.HR(S

NON-LOAD BEARING O HR(S

^HR(S

RHE ENCLOSURE OF EXITS _2.HR(S

SHAFTS K ELEVATOR HOISTWAVS _2.HR(S

MIXED USE SEPARATION O

(NONSEPERATED)

OTHER SEPARATION ASSEMUES _1_HR(S

EXIT ACCESS CORRDORS O.HR(S

TENANT SPACES SEPARATIONS .O HR(S

j_HR(s;

_i_HR(s;

d. FIRE PARTITIONS

e. DWELLING UNIT SEPARATIONS

f. SMOKE BARRIERS

g. OTHER NON-BEARING PARTITIONS O.HR(S

h. INT. BEARING WALLS & COLS, SUPPORTING MORE THAN I FLR. 0.HR(S;

SUPPORTING 1 FLR. OR ROOF ONLY QHR(S

i. STRUCTURAL MEMBERS SUPPORTING WALLS OHR(S;

j. FLOOR CONSTRUCTION INCLUDING BEAMS

k. ROOF CONSTRUCTION

OHR(S;

15" OR LESS 0HR(S

>15' TO <20" 0HR(S

20' OR MORE 0HR(S

9. MODIFICATIONS

PROVIDE MODIFICATION NUMBER AND CODE SECTION NUMBER

BEING MODIFIED

(a) EXISTING/APPROVED

(b) OUTSTANDING (NOT YET APPROVED)

10.

11.

ACCESSIBLE BUILDING

(EDUCATIONAL)

DESIGNATED

.NON-DESIGNATED

MINIMUM PLUMBING FIXTURE COUNT (P-1202)

(SENIOR CENTER)

FIRE SAFETY CODE DATA:

1. CLASSIFICATION OF OCCUPANCY

2. MINIMUM CONSTRUCTION REQUIRED

ACTUAL CONSTRUCTION PROVIDED

3. NOTIFICATION / ALARMS

4. DETECTION

5. EXTINGUISHMENT REQUIREMENTS

A3 ASSEMBUY

SB

2C

YES

NO

NO

NO

GENERAL NOTES

1. FOR SPECIFIC WALL DESIGNATIONS AND

A7

W/C

LAVS

D/F

REQUIRED

PROVIDED

12. CODES TO WHICH THIS PROJECT WAS DESIGNED

BOCA NATIONAL BUILDING CODE

BOCA ACCUMULATIVE SUPPLEMENT

CONNECTICUT SUPPLEMENT

DATED

2C04

13.

14.

15.

NFPA 101 WITH APPENDIX

CONNECTICUT SUPPLEMENT

NFPA REFERENCES

STATE HEALTH CODE

STATE HEALTH CODE SUPPLEMENT

OSHA

SECTION 504

NUMBER OF EXITS

FIRST FLOOR

TF5AVEL DISTANCE

ALLOWABLE

PROVIDED

NO. REQURIED

6-7-64 (49FR31626)

NO. PROVIDED

200'-0' MAX

eS'-O* MAX, FT.

FT.

FIRE PROTECTION SYSTEMS

(a) SUPPRESSION SYSTEM X_

(b) NOTIFICATION/ALARMS

(c) DETECTION

FULL LIMITED AREA

YES

YES

16.

17.

THRESHOLD LIMIT BUILDING

HISTORIC BUILDING

YES

YES

NO

NO

GENERAL HAZARDOUS AREAS NOTE

ALU STORAGE ROOMS, CUSTODIAN SPACES, BOILER ROOMS AND AREAS INDICATED

AS ONE HOUR SPACES ON DRAWINGS <Z^, M. A2, AND A3 SHALL HAVE A (1) ONE HOUR

FIRE RATING. FIRE SAFE ALL HOLES, CRACKS, AND PENETRATIONS TO PROVIDE A

(1) ONE HOUR FIRE RATING. SEE SEPClFICAT!ON SECTION 07270.

Drawing Title:

CODE PLAN

Date: Drawing Number:

AUG. 16, 2005

Scale:

Vd' = I'-o

Drawn By:

db Cl

Project Number:

04.166

Z:\West HartfDrd\Bishops Corner Senior Center 04.175\Drawings\CD's\Q4.166 -C-1 Codadwg, 8/25/2005 1:52:53 PM, 1:96