Barn Shop Drawings.pdf
PDF 4 MB Posted
- Attached to
- Central Office Additions State and local contract opportunity
- Solicitation number
- RFP # 2025-CO-0717
- Issued by
- El Paso County, Colorado
About this file
These are comprehensive shop drawings for a pre-engineered metal building (PEMB) prepared by Nucor Building Systems for the Bighorn Steel Buildings project located at 10850 Woodmen Road in Colorado Springs, Colorado. The drawings detail a D49 Barn project with job number U24L0388A, providing extensive technical specifications for a metal building system including structural framing plans, roof and wall sheeting details, fastener schedules, erection guidelines, and installation instructions. The documents cover critical technical aspects such as structural steel members, panel configurations, fastener types and spacing, seismic and wind load considerations, and specific installation requirements for roof and wall systems.
The shop drawings specify a single-story metal building with precise engineering specifications, including design code compliance with IBC 2021 Pike's Peak Regional Building Code, seismic design category, and wind load parameters. The documents include detailed technical notes on panel orientation, structural fastener spacing, side lap requirements, and specific installation procedures for various building components. While the drawings do not explicitly state pricing, they represent a fully engineered solution for the metal building structure, with comprehensive instructions for proper assembly, fastening, and integration of structural and architectural elements. The drawings are sealed by a registered professional engineer from Nucor Building Systems, indicating professional engineering review and certification of the design.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| Appendix C PEMB Covered Parking Quote.pdf | ||
| D49_Site_Bid-Drawings_250711.pdf | ||
| Overhead Coiling Doors Specs.pdf | ||
| Sample Contract.pdf | ||
| 2025 Contract Format NEW.pdf | ||
| Appendix C PEMB Barn Quote.pdf | ||
| Covered Parking Shop Drawings.pdf | ||
| Drainage Report.pdf | ||
| RFP_2025_CO_0717.pdf | ||
| Soils Report Kumar.pdf | ||
| D49_Barn_Bid-Drawings_250711.pdf | ||
| D49_CoveredParking_Bid-Drawings_250711.pdf | ||
| Final Q_A from Previous IFB.pdf | ||
| Q_A From 2ndIFB.pdf | ||
| Seeding _ Mulching City of Colorado Springs.pdf | ||
| D49 Bid Form 2025.docx | DOCX document | |
| GROUNDS EXPANSION BARN AND COVERED PARKING Project Manual-Bid Documents 20250711.pdf | ||
| RFP_Cover_Page _ Signature Sheet (2) (1).pdf |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FOR OCCUPANCY (RISK) CATEGORY I OR II, IBC PROVISIONS INDICATE THAT
SINGLE-STORY BUILDINGS SHALL HAVE "NO DRIFT LIMIT" PROVIDED THAT INTERIOR
WALLS, PARTITIONS, CEILINGS, AND EXTERIOR WALL SYSTEMS HAVE BEEN
DESIGNED TO ACCOMMODATE THE SEISMIC STORY DRIFTS. INTERIOR WALLS,
PARTITIONS, CEILINGS, OR EXTERIOR WALL SYSTEMS NOT PROVIDED BY THE
METAL BUILDING MANUFACTURER SHALL BE DESIGNED AND DETAILED BY OTHERS
TO ACCOMMODATE THE SEISMIC STORY DRIFTS. SEISMIC DRIFT VALUES MAY BE
OBTAINED FROM THE METAL BUILDING MANUFACTURER.
M O
ACCESSORIES (DOORS, WINDOWS, ETC.) NOT PROVIDED BY THE METAL BUILDING
MANUFACTURER MUST BE DESIGNED AS "COMPONENTS AND CLADDING" IN
ACCORDANCE WITH THE SPECIFIC WIND PROVISIONS OF THE REFERENCED
BUILDING CODE DISPLAYED ON THE COVER PAGE OF THIS DRAWING PACKET.
M O
FRAMED OPENINGS HAVE BEEN DESIGNED TO SUPPORT WIND LOAD NORMAL TO
THE WALL BASED ON THE STANDARD BUILDING CODE CRITERIA. FRAMED
OPENINGS HAVE NOT BEEN DESIGNED FOR ANY ADDITIONAL MOMENT OR
CATENARY FORCES FROM THE DOOR. ANY CHANGE TO THE INFORMATION SHOWN
HERE WILL REQUIRE AN ENGINEERING INVESTIGATION AND POSSIBLE BUILDING
REINFORCEMENT.
T hi s se al p er ta in s o n ly to th e m a te ri a ls de si gn ed a nd s u p p lie d b y
N u co r
B ui ld in g S ys te m s, a d iv is io n o f N u co r C or po ra tio n.
T h e d ra w in g s a n d th e m et al b ui ld in g s w h ic h th e y re p re se n t ar e th e pr od u ct o f N u co r
B u ild in g S ys te m s.
T h e r e g is te r p ro fe ss io n a l en gi ne er w ho se s e a l a p p e a rs o n th e se dr aw in gs is e m p lo ye d b y N u co r B ui ld in gs
S ys te m s a n d d o e s n o t s e rv e as o r r ep re se n t t h e p ro je ct e n g in e e r o f re co rd a nd s h a ll n o t b e c o n st ru e d as s u ch
S H
E E
T
IS
S
U E
D W
N C
H K
E N
G P
E D
A T
E P
R O
JE
C
T N
A M
E
C U
S T
O M
E R
N A
M E
JO
B
N U
M B
E R
S H
E E
T T
IT
L
E
C O
F
B
IG
H O
R N
S T
E E
L B
U
IL
D
IN
G S
D B
A R
N R
U L
A
W O
O D
M E
N R
D C
O L
O R
A D
O S
P R
IN
G
S C
O
P U
E B
L O
C
O
05/30/2024
T hi s se al p er ta in s o n ly to th e m a te ri a ls de si gn ed a nd s u p p lie d b y
N u co r
B ui ld in g S ys te m s, a d iv is io n o f N u co r C or po ra tio n.
T h e d ra w in g s a n d th e m et al b ui ld in g s w h ic h th e y re p re se n t ar e th e pr od u ct o f N u co r
B u ild in g S ys te m s.
T h e r e g is te r p ro fe ss io n a l en gi ne er w ho se s e a l a p p e a rs o n th e se dr aw in gs is e m p lo ye d b y N u co r B ui ld in gs
S ys te m s a n d d o e s n o t s e rv e as o r r ep re se n t t h e p ro je ct e n g in e e r o f re co rd a nd s h a ll n o t b e c o n st ru e d as s u ch
S H
E E
T
IS
S
U E
D W
N C
H K
E N
G P
E D
A T
E P
R O
JE
C
T N
A M
E
C U
S T
O M
E R
N A
M E
JO
B
N U
M B
E R
S H
E E
T T
IT
L
E
F O
F
B
IG
H O
R N
S T
E E
L B
U
IL
D
IN
G S
D B
A R
N R
U L
A
W O
O D
M E
N R
D C
O L
O R
A D
O S
P R
IN
G
S C
O
P U
E B
L O
C s se al p er ta in s o n ly to th e m a te ri a ls de si gn ed a nd s u p p lie d b y
N u co r
B ui ld in g S ys te m s, a d iv is io n o f N u co r C or po ra tio n.
T h e d ra w in g s a n d th e m et al b ui ld in g s w h ic h th e y re p re se n t ar e th e pr od u ct o f N u co r
B u ild in g S ys te m s.
T h e r e g is te r p ro fe ss io n a l en gi ne er w ho se s e a l a p p e a rs o n th e se dr aw in gs is e m p lo ye d b y N u co r B ui ld in gs
S ys te m s a n d d o e s n o t s e rv e as o r r ep re se n t t h e p ro je ct e n g in e e r o f re co rd a nd s h a ll n o t b e c o n st ru e d as s u ch
S H
E E
T
IS
S
U E
D W
N C
H K
E N
G P
E D
A T
E P
R O
JE
C
T N
A M
E
C U
S T
O M
E R
N A
M E
JO
B
N U
M B
E R
S H
E E
T T
IT
L
E
F O
F
B
IG
H O
R N
S T
E E
L B
U
IL
D
IN
G S
D B
A R
N R
U L
A
W O
O D
M E
N R
D C
O L
O R
A D
O S
P R
IN
G
S C
O
P U
E B
L O
C s se al p er ta in s o n ly to th e m a te ri a ls de si gn ed a nd s u p p lie d b y
N u co r
B ui ld in g S ys te m s, a d iv is io n o f N u co r C or po ra tio n.
T h e d ra w in g s a n d th e m et al b ui ld in g s w h ic h th e y re p re se n t ar e th e pr od u ct o f N u co r
B u ild in g S ys te m s.
T h e r e g is te r p ro fe ss io n a l en gi ne er w ho se s e a l a p p e a rs o n th e se dr aw in gs is e m p lo ye d b y N u co r B ui ld in gs
S ys te m s a n d d o e s n o t s e rv e as o r r ep re se n t t h e p ro je ct e n g in e e r o f re co rd a nd s h a ll n o t b e c o n st ru e d as s u ch
S H
E E
T
IS
S
U E
D W
N C
H K
E N
G P
E D
A T
E P
R O
JE
C
T N
A M
E
C U
S T
O M
E R
N A
M E
JO
B
N U
M B
E R
S H
E E
T T
IT
L
E
E O
F
B
IG
H O
R N
S T
E E
L B
U
IL
D
IN
G S
D B
A R
N R
U L
A
W O
O D
M E
N R
D C
O L
O R
A D
O S
P R
IN
G
S C
O
P U
E B
L O
C s se al p er ta in s o n ly to th e m a te ri a ls de si gn ed a nd s u p p lie d b y
N u co r
B ui ld in g S ys te m s, a d iv is io n o f N u co r C or po ra tio n.
T h e d ra w in g s a n d th e m et al b ui ld in g s w h ic h th e y re p re se n t ar e th e pr od u ct o f N u co r
B u ild in g S ys te m s.
T h e r e g is te r p ro fe ss io n a l en gi ne er w ho se s e a l a p p e a rs o n th e se dr aw in gs is e m p lo ye d b y N u co r B ui ld in gs
S ys te m s a n d d o e s n o t s e rv e as o r r ep re se n t t h e p ro je ct e n g in e e r o f re co rd a nd s h a ll n o t b e c o n st ru e d as s u ch
S H
E E
T
IS
S
U E
D W
N C
H K
E N
G P
E D
A T
E P
R O
JE
C
T N
A M
E
C U
S T
O M
E R
N A
M E
JO
B
N U
M B
E R
S H
E E
T T
IT
L
E
E O
F
B
IG
H O
R N
S T
E E
L B
U
IL
D
IN
G S
D B
A R
N R
U L
A
W O
O D
M E
N R
D C
O L
O R
A D
O S
P R
IN
G
S C
O
P U
E B
L O
C s se al p er ta in s o n ly to th e m a te ri a ls de si gn ed a nd s u p p lie d b y
N u co r
B ui ld in g S ys te m s, a d iv is io n o f N u co r C or po ra tio n.
T h e d ra w in g s a n d th e m et al b ui ld in g s w h ic h th e y re p re se n t ar e th e pr od u ct o f N u co r
B u ild in g S ys te m s.
T h e r e g is te r p ro fe ss io n a l en gi ne er w ho se s e a l a p p e a rs o n th e se dr aw in gs is e m p lo ye d b y N u co r B ui ld in gs
S ys te m s a n d d o e s n o t s e rv e as o r r ep re se n t t h e p ro je ct e n g in e e r o f re co rd a nd s h a ll n o t b e c o n st ru e d as s u ch
S H
E E
T
IS
S
U E
D W
N C
H K
E N
G P
E D
A T
E P
R O
JE
C
T N
A M
E
C U
S T
O M
E R
N A
M E
JO
B
N U
M B
E R
S H
E E
T T
IT
L
E
E O
F
B
IG
H O
R N
S T
E E
L B
U
IL
D
IN
G S
D B
A R
N R
U L
A
W O
O D
M E
N R
D C
O L
O R
A D
O S
P R
IN
G
S C
O
P U
E B
L O
C s se al p er ta in s o n ly to th e m a te ri a ls de si gn ed a nd s u p p lie d b y
N u co r
B ui ld in g S ys te m s, a d iv is io n o f N u co r C or po ra tio n.
T h e d ra w in g s a n d th e m et al b ui ld in g s w h ic h th e y re p re se n t ar e th e pr od u ct o f N u co r
B u ild in g S ys te m s.
T h e r e g is te r p ro fe ss io n a l en gi ne er w ho se s e a l a p p e a rs o n th e se dr aw in gs is e m p lo ye d b y N u co r B ui ld in gs
S ys te m s a n d d o e s n o t s e rv e as o r r ep re se n t t h e p ro je ct e n g in e e r o f re co rd a nd s h a ll n o t b e c o n st ru e d as s u ch
S H
E E
T
IS
S
U E
D W
N C
H K
E N
G P
E D
A T
E P
R O
JE
C
T N
A M
E
C U
S T
O M
E R
N A
M E
JO
B
N U
M B
E R
S H
E E
T T
IT
L
E
E O
F
B
IG
H O
R N
S T
E E
L B
U
IL
D
IN
G S
D B
A R
N R
U L
A
W O
O D
M E
N R
D C
O L
O R
A D
O S
P R
IN
G
S C
O
P U
E B
L O
C s se al p er ta in s o n ly to th e m a te ri a ls de si gn ed a nd s u p p lie d b y
N u co r
B ui ld in g S ys te m s, a d iv is io n o f N u co r C or po ra tio n.
T h e d ra w in g s a n d th e m et al b ui ld in g s w h ic h th e y re p re se n t ar e th e pr od u ct o f N u co r
B u ild in g S ys te m s.
T h e r e g is te r p ro fe ss io n a l en gi ne er w ho se s e a l a p p e a rs o n th e se dr aw in gs is e m p lo ye d b y N u co r B ui ld in gs
S ys te m s a n d d o e s n o t s e rv e as o r r ep re se n t t h e p ro je ct e n g in e e r o f re co rd a nd s h a ll n o t b e c o n st ru e d as s u ch
S H
E E
T
IS
S
U E
D W
N C
H K
E N
G P
E D
A T
E P
R O
JE
C
T N
A M
E
C U
S T
O M
E R
N A
M E
JO
B
N U
M B
E R
S H
E E
T T
IT
L
E
E O
F
B
IG
H O
R N
S T
E E
L B
U
IL
D
IN
G S
D B
A R
N R
U L
A
W O
O D
M E
N R
D C
O L
O R
A D
O S
P R
IN
G
S C
O
P U
E B
L O
C s se al p er ta in s o n ly to th e m a te ri a ls de si gn ed a nd s u p p lie d b y
N u co r
B ui ld in g S ys te m s, a d iv is io n o f N u co r C or po ra tio n.
T h e d ra w in g s a n d th e m et al b ui ld in g s w h ic h th e y re p re se n t ar e th e pr od u ct o f N u co r
B u ild in g S ys te m s.
T h e r e g is te r p ro fe ss io n a l en gi ne er w ho se s e a l a p p e a rs o n th e se dr aw in gs is e m p lo ye d b y N u co r B ui ld in gs
S ys te m s a n d d o e s n o t s e rv e as o r r ep re se n t t h e p ro je ct e n g in e e r o f re co rd a nd s h a ll n o t b e c o n st ru e d as s u ch
S H
E E
T
IS
S
U E
D W
N C
H K
E N
G P
E D
A T
E P
R O
JE
C
T N
A M
E
C U
S T
O M
E R
N A
M E
JO
B
N U
M B
E R
S H
E E
T T
IT
L
E
E O
F
B
IG
H O
R N
S T
E E
L B
U
IL
D
IN
G S
D B
A R
N R
U L
A
W O
O D
M E
N R
D C
O L
O R
A D
O S
P R
IN
G
S C
O
P U
E B
L O
C
LOW EAVE BYPASS SW GIRT CONDITION
(2) H1020 (1)
MAH01
PART
ROOF
J2
EAVE STRUT AT INTERIOR FRAME
USE (4) 1/2" X 2" A325 BOLT H0603/NUT H0300 U.N.O.
CAP PLATE/
BOLTS REQ'D AS SHOWN
3"
RAFTER/
SEC. A
ANGLE MK.
MAH__
PER END
MK. ESW01 (2)
PLATE WASHER
1:12
MAH02 2:12
MAH03 3:12
MAH04 4:12
SLOPE
SHOP WELDED SHELF
1/4"
BA0020
T hi s se al p er ta in s o n ly to th e m a te ri a ls de si gn ed a nd s u p p lie d b y
N u co r
B ui ld in g S ys te m s, a d iv is io n o f N u co r C or po ra tio n.
T h e d ra w in g s a n d th e m et al b ui ld in g s w h ic h th e y re p re se n t ar e th e pr od u ct o f N u co r
B u ild in g S ys te m s.
T h e r e g is te r p ro fe ss io n a l en gi ne er w ho se s e a l a p p e a rs o n th e se dr aw in gs is e m p lo ye d b y N u co r B ui ld in gs
S ys te m s a n d d o e s n o t s e rv e as o r r ep re se n t t h e p ro je ct e n g in e e r o f re co rd a nd s h a ll n o t b e c o n st ru e d as s u ch
S H
E E
T
IS
S
U E
D W
N C
H K
E N
G P
E D
A T
E P
R O
JE
C
T N
A M
E
C U
S T
O M
E R
N A
M E
JO
B
N U
M B
E R
S H
E E
T T
IT
L
E
D O
F
B
IG
H O
R N
S T
E E
L B
U
IL
D
IN
G S
D B
A R
N R
U L
A
W O
O D
M E
N R
D C
O L
O R
A D
O S
P R
IN
G
S C
O
P U
E B
L O
C
NAA0030
ROD ASSEMBLY MK.
HILLSIDE WASHER,
COUPLING NUT
WEB OF COLUMN
COUPLING NUTSROD MARK HILLSIDE FLAT A307/A325
SEE PLANS AND ELEVATIONS FOR BRACING
Q3
ROD BRACE DETAIL
WEB TO WEB
RD__-
FLAT WASHER, AND
NUT
IF REQUIRED
OR RAFTER
(QTY VARIES)DIAMETER NUMBER WASHERS WASHERS NUTS
MARK NUMBERS
H0860
(2) H0450
(2) H0240
(2) H0285RD06-
RD05-
RD07-
RD08-
RD09-
RD10-
(2) H0280
(2) H0285
(2) H0290
(2) H0290
(2) H0295
(2) H0230
(2) H0220
(2) H0210
(2) H0250
(2) H0260 (2) H0340
(2) H0325
(2) H0320
(2) H0310
(2) H0330
H0850
H0840
H0830
H0810
H0820
AF0011
T hi s se al p er ta in s o n ly to th e m a te ri a ls de si gn ed a nd s u p p lie d b y
N u co r
B ui ld in g S ys te m s, a d iv is io n o f N u co r C or po ra tio n.
T h e d ra w in g s a n d th e m et al b ui ld in g s w h ic h th e y re p re se n t ar e th e pr od u ct o f N u co r
B u ild in g S ys te m s.
T h e r e g is te r p ro fe ss io n a l en gi ne er w ho se s e a l a p p e a rs o n th e se dr aw in gs is e m p lo ye d b y N u co r B ui ld in gs
S ys te m s a n d d o e s n o t s e rv e as o r r ep re se n t t h e p ro je ct e n g in e e r o f re co rd a nd s h a ll n o t b e c o n st ru e d as s u ch
S H
E E
T
IS
S
U E
D W
N C
H K
E N
G P
E D
A T
E P
R O
JE
C
T N
A M
E
C U
S T
O M
E R
N A
M E
JO
B
N U
M B
E R
S H
E E
T T
IT
L
E
D O
F
B
IG
H O
R N
S T
E E
L B
U
IL
D
IN
G S
D B
A R
N R
U L
A
W O
O D
M E
N R
D C
O L
O R
A D
O S
P R
IN
G
S C
O
P U
E B
L O
C
EAVE STRUT ANGLE
LINER LOW EAVE ANGLE
LINER EAVE ANGLE
LINER EAVE ANGLE
EAVE ANGLE
EAVE ANGLE
GIRT ANGLE
GIRT ANGLE
GIRT ANGLE
GIRT ANGLE
RAKE PARAPET ANGLE
RAKE PARAPET ANGLE
RAKE ANGLE
STANDING SEAM RAKE/EAVE STRUT ANGLE
LINER EAVE ANGLE
NA00030
STANDARD ANGLE SCHEDULE
GALVANIZED
1" x 2-1/2" x 12"
GALVANIZED
6" x 7-3/4" x 120"
GALVANIZED
3" x 3" x 120"
GALVANIZED
3" x 7-3/4" x 120"
GALVANIZED
4" x 5" x 120"
GALVANIZED
5" x 8" x 120"
GALVANIZED
1" x 2-1/2" x 12"
GALVANIZED
1" x 2-1/2" x 24"
GALVANIZED
1" x 2-1/2" x 30"
GALVANIZED
1" x 2-1/2" x 120"
GALVANIZED
2" x 12" x 120"
GALVANIZED
6" x 6" x 120"
GALVANIZED
3" x 5" x 242"
BASE ANGLE
GALVANIZED
2" x 3" x 242"
GALVANIZED
1" x 2-1/2" x 12"
GALVANIZED
3" x 5" x 120"
A00030
T hi s se al p er ta in s o n ly to th e m a te ri a ls de si gn ed a nd s u p p lie d b y
N u co r
B ui ld in g S ys te m s, a d iv is io n o f N u co r C or po ra tio n.
T h e d ra w in g s a n d th e m et al b ui ld in g s w h ic h th e y re p re se n t ar e th e pr od u ct o f N u co r
B u ild in g S ys te m s.
T h e r e g is te r p ro fe ss io n a l en gi ne er w ho se s e a l a p p e a rs o n th e se dr aw in gs is e m p lo ye d b y N u co r B ui ld in gs
S ys te m s a n d d o e s n o t s e rv e as o r r ep re se n t t h e p ro je ct e n g in e e r o f re co rd a nd s h a ll n o t b e c o n st ru e d as s u ch
S H
E E
T
IS
S
U E
D W
N C
H K
E N
G P
E D
A T
E P
R O
JE
C
T N
A M
E
C U
S T
O M
E R
N A
M E
JO
B
N U
M B
E R
S H
E E
T T
IT
L
E
D O
F
B
IG
H O
R N
S T
E E
L B
U
IL
D
IN
G S
D B
A R
N R
U L
A
W O
O D
M E
N R
D C
O L
O R
A D
O S
P R
IN
G
S C
O
P U
E B
L O
C
A00040
ROOF TRIM SCHEDULE
LOW EAVE, HIGH EAVE, GABLE/RAKE, RIDGE TRIM, EXTENSIONS, &
HIP/VALLEY PROFILES
GHP121
HORIZ. GUTT. POSITION TRIM
GHS_121
HORIZ. GUTTER SUPPORT
HRP_121
H.E. PARA. TRIM - R-PANEL
121 & 242
H.E. SCULP. TRIM - R-PANEL
HTSN___
LEM121
LOW EAVE - MASONRY
LEU121
LOW EAVE - EXTENSION
RSS121
RAKE SPACER - JOISTS
RVL_121
RIDGE - VERTICAL RIB
RTP___
121 & 242
RIDGE - TRAPEZOIDAL PANEL
RTR121
ROOF TRIM RETAINER
HVP_121
HIGH EAVE PARA. - VERTICAL RIB
121 & 242
HIGH EAVE SCULP. - VERTICAL RIB
RIPJ121
RIDGE. INSULATION PAN - JOISTS
RPU121
RAKE PARAPET TRIM
121 & 242
SCULPTURED GUTTER
RVCC182
RIDGE VR CLOSURE COVER
RVCZ122
VERT. RIB RIDGE CLOSURE ZEE
121 & 242
SCULPTURED RAKE TRIM
HRSN___ HTP_121
HIGH EAVE PARA. - TRAP. PANEL
GSN___
121 & 242
HIGH EAVE SCULP. - TRAP PANEL
HVSN___ LBU121
121 & 242
LOW EAVE - BASIC
RSN___
NOTE: TRIM PROFILE SCALE VARIES
RIPP181
RIDGE INSULATION PAN - PURLINS
ETC_121
EXTENSION TRIM AT EAVE CEE
ETH_121
HIGH EAVE EXTENSION TRIM
ETL_121
LOW EAVE TRIM AT RAKE EXT.
ETR_121
RAKE EXTENSION TRIM
ETS_121
EXT. TRIM AT EAVE "S"
ETU_121
UNIVERSAL EXTENSION TRIM
NBS
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
17 18 19 20 21 22 23 24
25 26 27 28 29 30 31 32
33 34 35 36 37 38 39 40
41 42 43 44 45 46
HAT_120
HAT CHANNEL
HCT_121
HIP CAP TRIM (TRAPEZOIDAL PNL.)
HIP_120
HIP INSULATION PAN
HPL_120
HIP PLATE
HRJ121
HIP RIB JAY
VDF_121
VALLEY DIVERTER
VIP_120
VALLEY INSULATION PAN
VPL_120
VALLEY PLATE
HCV_121
HIP CAP TRIM (VERTICAL RIB PNL.)
HMCR121
HIP METAL CLOSURE (R-PANEL)
A
HBT120
HIP BACKER (TRAP. PANELS)
T hi s se al p er ta in s o n ly to th e m a te ri a ls de si gn ed a nd s u p p lie d b y
N u co r
B ui ld in g S ys te m s, a d iv is io n o f N u co r C or po ra tio n.
T h e d ra w in g s a n d th e m et al b ui ld in g s w h ic h th e y re p re se n t ar e th e pr od u ct o f N u co r
B u ild in g S ys te m s.
T h e r e g is te r p ro fe ss io n a l en gi ne er w ho se s e a l a p p e a rs o n th e se dr aw in gs is e m p lo ye d b y N u co r B ui ld in gs
S ys te m s a n d d o e s n o t s e rv e as o r r ep re se n t t h e p ro je ct e n g in e e r o f re co rd a nd s h a ll n o t b e c o n st ru e d as s u ch
S H
E E
T
IS
S
U E
D W
N C
H K
E N
G P
E D
A T
E P
R O
JE
C
T N
A M
E
C U
S T
O M
E R
N A
M E
JO
B
N U
M B
E R
S H
E E
T T
IT
L
E
D O
F
B
IG
H O
R N
S T
E E
L B
U
IL
D
IN
G S
D B
A R
N R
U L
A
W O
O D
M E
N R
D C
O L
O R
A D
O S
P R
IN
G
S C
O
P U
E B
L O
C
MFA121
MISCELLANEOUS FILLER TRIM
CW____
MULTI.
HEAD WRAP COVER
CIA121
INSIDE CORNER TRIM - ALT
BSA___
121 / 242
BASE ANGLE TRIM
BSB121
BASE TRIM
CIB121
INSIDE CORNER TRIM- BASIC
DJ_088
JAMB COVER TRIM - WALK D.
MFR121
MISCELLANEOUS FILLER TRIM
PR_072
PARTITION FLASHING
HTA___
MULTI.
HEADER TRIM
CIT121
IINSIDE CORNER TRIM - TRANS.
BSC121
BASE TRIM
PT_121
PARTITION FLASHING
HTD___
MULTI.
WINDOW & LINER TRIM
COA121
OUTSIDE CORNER TRIM - ALT.
BSD121
BASE TRIM
BSE121
BASE TRIM
COB121
OUTSIDE CORNER TRIM - BASIC
IC_121
INSET / OUTSET TRIM
PTC121
PARTITION TRIM COVER
STA___
MULTI.
SILL TRIM
IT_121
INSET / OUTSET TRIM
COT121
OUTSIDE CORNER TRIM - TRANS.
BSF121
BASE TRIM
BSW121
WAINSCOT TRIM
CS____
MULTI.
"S" CHANNEL COVER
JTA___
MULTI.
JAMB TRIM - R-PANEL & A-PANEL
WJ____
MULTI.
JAMB COVER TRIM @ WINDOW
JTD___
MULTI.
JAMB TRIM - REV. R-PANEL
CT_121
CAP TRIM
CC____
MULTI.
CEE CHANNEL COVER TRIM
WALL TRIM SCHEDULE
BASE, CORNER, FRAMED OPENINGS, INSET/OUTSET, AND PARTITION TRIM
PROFILES
NOTE: TRIM PROFILE SCALE VARIES
A00050
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
NAME:
LEN (IN.):
DESC:
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
17 18 19 20 21 22 23 24
25 26 27 28 29 30 31 32
33 34 35 36 37 38 39 40
41 42 43 44 45 46
T hi s se al p er ta in s o n ly to th e m a te ri a ls de si gn ed a nd s u p p lie d b y
N u co r
B ui ld in g S ys te m s, a d iv is io n o f N u co r C or po ra tio n.
T h e d ra w in g s a n d th e m et al b ui ld in g s w h ic h th e y re p re se n t ar e th e pr od u ct o f N u co r
B u ild in g S ys te m s.
T h e r e g is te r p ro fe ss io n a l en gi ne er w ho se s e a l a p p e a rs o n th e se dr aw in gs is e m p lo ye d b y N u co r B ui ld in gs
S ys te m s a n d d o e s n o t s e rv e as o r r ep re se n t t h e p ro je ct e n g in e e r o f re co rd a nd s h a ll n o t b e c o n st ru e d as s u ch
S H
E E
T
IS
S
U E
D W
N C
H K
E N
G P
E D
A T
E P
R O
JE
C
T N
A M
E
C U
S T
O M
E R
N A
M E
JO
B
N U
M B
E R
S H
E E
T T
IT
L
E
D O
F
B
IG
H O
R N
S T
E E
L B
U
IL
D
IN
G S
D B
A R
N R
U L
A
W O
O D
M E
N R
D C
O L
O R
A D
O S
P R
IN
G
S C
O
P U
E B
L O
C
R
O F
F A
S T
E N
E R
S R
IV
E
T S
S
P E
C
IA
L T
Y F
A S
T E
N E
R S
H
H
H
H
H
H
H
H
H
H H
H H
H
H
H
H
H
H
Self-Drilling Screw
1/4-14 x 1 1/4" TCP 3 w/o Washer
5/16" Head
Self-Drilling Screw
1/4-14 x 2" TCP 3 w/o Washer
3/8" Head
Color: Available in "No Paint" Only
Color: Available in "No Paint" Only
Panel Clips
Attach panel clips, rake angle clips, eave plate to purlins with insulation ≤
R19
Attach misc light gauge material to secondary
RECOMMENDED TOOL TYPES
2000 RPM MAX
Torque adjustable clutch, 4 AMP or higher
DO NOT use impacting tools
DRILLING CAPACITY
0.110 MIN / 0.250 MAX
Pre-Drill Diameter: 3/16" Ø
DRILLING CAPACITY
0.110 MIN / 0.250 MAX
Pre-Drill Diameter: 3/16" Ø
Self-Drilling Screw
12-24 x 1 1/2" TCP 5 w/o Washer
5/16" Head
Color: Check w/ local plant
Self-Drilling Screw SDI
12-24 x 1 1/2" #5 Drilltite w/o Wash
5/16" Head (Painted Orange)
(Vendor: Black & Decker)
Color: Available in "No Paint" Only
RECOMMENDED TOOL TYPES
2000 RPM MAX
Torque adjustable clutch, 4 AMP or higher
DO NOT use impacting tools
Panel Clips - Hot Roll
Attach panel clips, rake angle clips, eave plate to joist with insulation ≤ R19
Attach misc light gauge material to HR secondary
DRILLING CAPACITY
0.250 MIN / 0.500 MAX
Pre-Drill Diameter: 3/16" Ø
RECOMMENDED TOOL TYPES
1800 RPM MAX
Torque adjustable clutch, 4 AMP or higher
DO NOT use impacting tools
DRILLING CAPACITY
0.250 MIN / 0.500 MAX
Pre-Drill Diameter: 3/16" Ø
RECOMMENDED TOOL TYPES
1800 RPM MAX
Torque adjustable clutch, 4 AMP or higher
DO NOT use impacting tools
Used to attach deck to joist with high seismic loads
NOT to be used for roof clips
Available for Utah only
Panel Clips - Long
Attach panel clips, rake angle clips, eave plate to purlins with insulation
>R19 and ≤ R38
Self-Drilling Screw
12-24 x 2" TCP 5 w/o Washer
5/16" Head
Color: Check w/ local plant
Panel Clips - Hot Roll
- Long
Attach panel clips, rake angle clips, eave plate to joist with insulation > R19 and ≤ R38
DRILLING CAPACITY
0.250 MIN / 0.500 MAX
Pre-Drill Diameter: 3/16" Ø
RECOMMENDED TOOL TYPES
1800 RPM MAX
Torque adjustable clutch, 4 AMP or higher
DO NOT use impacting tools
Wall Structural
Used to attach wall panel, wall flashing and light gauge parts with insulation
≤ R13
Self-Drilling Screw
12-14 x 1 1/4" TCP 3 5/16" Head
H1040 - w/o Washer
H1041 - w/ Washer
Self-Drilling Screw
12-14 x 2" TCP 3 5/16" Head
H1045 - w/o Washer
H1047 - w/ Washer
Color: All Standard SMP & PVDF
Check local plant stock inventory
Color: All Standard SMP & PVDF
Check local plant stock inventory
DRILLING CAPACITY
0.050 MIN / 0.140 MAX
Pre-Drill Diameter: 5/32" Ø
Wall Structural - Long
Used to attach wall panel, wall flashing and light gauge parts with insulation
> R13 and ≤ R19
DRILLING CAPACITY
0.090 MIN / 0.210 MAX
Pre-Drill Diameter: 3/16" Ø
RECOMMENDED TOOL TYPES
2000 RPM MAX
Torque adjustable clutch, 4 AMP or higher
DO NOT use impacting tools
RECOMMENDED TOOL TYPES
2000 RPM MAX
Torque adjustable clutch, 4 AMP or higher
DO NOT use impacting tools
SELF-TAPPING SCREW
(GOOF SCREW)
17-14 x 1" w/ Washer
5/16" UltiMate Head
Self-Drilling Screw
12-14 x 2" TCP 3 w/ Washer
5/16" UltiMate Head
Color: All Standard SMP & PVDF
Check local plant stock inventory
"Goof Screw"
Used at locations on roof, where fastener has stripped out.
RECOMMENDED TOOL TYPES
2000 RPM MAX
Torque adjustable clutch
DO NOT use impacting tools
DRILLING CAPACITY
N/A
Roof Structural
Used to attach roof panel, roof flashing, end laps and light gauge parts with insulation ≤ R16
Self-Drilling Screw
1/4-14 x 1 1/4" TCP 3 w/ Washer
5/16" UltiMate Head
Self-Drilling Screw
12-14 x 1 1/2" TCP 3 w/ Washer
5/16" UltiMate Head
Color: All Standard SMP & PVDF
Check local plant stock inventory
Color: All Standard SMP & PVDF
Check local plant stock inventory
Roof Structural - Long
Used to attach roof panel, roof flashing, end laps and light gauge parts with insulation = R19
DRILLING CAPACITY
0.090 MIN / 0.210 MAX
Pre-Drill Diameter: 3/16" Ø
DRILLING CAPACITY
0.050 MIN / 0.140 MAX
Pre-Drill Diameter: 5/32" Ø
Self-Drilling Screw
1/4-14 x 7/8" TCP 1 w/ Washer
5/16" UltiMate Head
Color: All Standard SMP & PVDF
Check local plant stock inventory
RECOMMENDED TOOL TYPES
2000 RPM MAX
Torque adjustable clutch, 4 AMP or higher
DO NOT use impacting tools
RECOMMENDED TOOL TYPES
2000 RPM MAX
Torque adjustable clutch, 4 AMP or higher
DO NOT use impacting tools
RECOMMENDED TOOL TYPES
2000 RPM MAX
Torque adjustable clutch, 4 AMP or higher
DO NOT use impacting tools
Roof Stitch
Used to attach roof trim end laps and trim to roof panel
DRILLING CAPACITY
0.035 MIN / 0.090 MAX
Pre-Drill Diameter: 1/8" Ø
RECOMMENDED TOOL TYPES
2000 RPM MAX
Torque adjustable clutch, 4 AMP or higher
DO NOT use impacting tools
Vented ridge
-To accomodate the thickness of Purlin Vent from Cor-A-Vent
Color: All Standard SMP & PVDF
Check local plant stock inventory
Pop Rivet
1/8" x 3/16"
Stainless Steel Blind Pop Rivet
Grommet Fastener
3/8" Diameter Stainless
Grommet Seal
Color: All Standard SMP & PVDF
Check local plant stock inventory
Color: Available in "No Paint" Only
Used at trim laps, corner caps, and attaching trim to panel where stitch fasteners can't be used
RECOMMENDED TOOL TYPES
Manual or electric rivet tool
DO NOT use impacting tools
RECOMMENDED TOOL TYPES
Torque adjustable clutch grommet tool
DO NOT use impacting tools
Used at translucent panel to metal side lap connections
Self-Drilling Screw
12-14 x 1" TCP 3
Square / Phillips Pancake Head
Color: Available in "No Paint" Only
Self-Tapping Fastener
10-12 X 1"
Square / Phillips Pancake Head
Self-Tapping Fastener
10-14 X 1-1/2" Woodtite w/ Washer
1/4" Head
Color: All Standard SMP & PVDF
Check local plant stock inventory
Color: Available in "No Paint" Only
DRILLING CAPACITY
0.090 MIN / 0.210 MAX
Pre-Drill Diameter: 3/16" Ø
RECOMMENDED TOOL TYPES
2000 RPM MAX
Torque adjustable clutch, 4 AMP or higher
DO NOT use impacting tools
Pancake Screw
Used to attach panel clips and rake angle to purlins
**ONLY WITH ZERO
STANDOFF CLIPS
Wood Structural
Used to attach panel and trim to wood structure
Non-Stock Special Order
Fastener
Wood Clip Screw
Panel clips to wood
**Only 0" offset clips
Non-Stock Special Order
Fastener
RECOMMENDED TOOL TYPES
2000-2500 RPM
Torque adjustable clutch, 4 AMP or higher
DO NOT use impacting tools
RECOMMENDED TOOL TYPES
2000-2500 RPM
Torque adjustable clutch, 4 AMP or higher
DO NOT use impacting tools
Insulation Retainer Washer
1/4 x 1-1/4" F8 Fender Washer
(1 1/4" O.D. w/ 5/16" I.D.)
Color: Available in "No Paint" Only
RECOMMENDED TOOL TYPES
N/A
Used in conjunction with
H1020 fasteners to secure roof insulation. Reference roofline trim details for specific applications.
H
DRILLING CAPACITY
0.110 MIN / 0.250 MAX
Pre-Drill Diameter: 3/16" Ø
H H
1 Self-Drilling Screw
12-24 x 1 1/2" TCP 5 5/16" Head
H1070 - w/o Washer
H1071 - w/ Washer
DRILLING CAPACITY
0.250 MIN / 0.500 MAX
Pre-Drill Diameter: 3/16" Ø
RECOMMENDED TOOL TYPES
1800 RPM MAX
Torque adjustable clutch, 4 AMP or higher
DO NOT use impacting tools
Color: All Standard SMP & PVDF
Check local plant stock inventory
Wall Structural
-HR w/ Washer
-HR w/o Washer
Used to attach wall panel and trims to hot roll members with insulation
≤ R13
H
Self-Drilling Screw
12-24 x 2" TCP 5 w/o Washer
5/16" Head
Color: Check w/ local plant
DRILLING CAPACITY
0.250 MIN / 0.500 MAX
Pre-Drill Diameter: 3/16" Ø
RECOMMENDED TOOL TYPES
1800 RPM MAX
Torque adjustable clutch, 4 AMP or higher
DO NOT use impacting tools
Wall Structural
-HR w/o Washer
Used to attach wall panel and trims to hot roll members with insulation
> R13 and ≤ R19
H H
1 Self-Drilling Screw
1/4-14 x 7/8" TCP 1 5/16" Head
H1060 - w/o Washer
H1061 - w/ Washer
Color: All Standard SMP & PVDF
Check local plant stock inventory
DRILLING CAPACITY
0.035 MIN / 0.090 MAX
Pre-Drill Diameter: 1/8" Ø
RECOMMENDED TOOL TYPES
2000 RPM MAX
Torque adjustable clutch, 4 AMP or higher
DO NOT use impacting tools
Wall Stitch
Used to attach wall trim end laps and trim to wall panel
A00100
T hi s se al p er ta in s o n ly to th e m a te ri a ls de si gn ed a nd s u p p lie d b y
N u co r
B ui ld in g S ys te m s, a d iv is io n o f N u co r C or po ra tio n.
T h e d ra w in g s a n d th e m et al b ui ld in g s w h ic h th e y re p re se n t ar e th e pr od u ct o f N u co r
B u ild in g S ys te m s.
T h e r e g is te r p ro fe ss io n a l en gi ne er w ho se s e a l a p p e a rs o n th e se dr aw in gs is e m p lo ye d b y N u co r B ui ld in gs
S ys te m s a n d d o e s n o t s e rv e as o r r ep re se n t t h e p ro je ct e n g in e e r o f re co rd a nd s h a ll n o t b e c o n st ru e d as s u ch
S H
E E
T
IS
S
U E
D W
N C
H K
E N
G P
E D
A T
E P
R O
JE
C
T N
A M
E
C U
S T
O M
E R
N A
M E
JO
B
N U
M B
E R
S H
E E
T T
IT
L
E
D O
F
B
IG
H O
R N
S T
E E
L B
U
IL
D
IN
G S
D B
A R
N R
U L
A
W O
O D
M E
N R
D C
O L
O R
A D
O S
P R
IN
G
S C
O
P U
E B
L O
C
WALL PANEL ERECTION
1. BLOCK GIRTS TO "LEVEL" POSITION BEFORE
STARTING PANEL ERECTION. MAINTAIN WOOD
BLOCKING (NOT BY METAL BUILDING SUPPLIER) UNTIL
PANEL TO STRUCTURAL FASTENERS ARE INSTALLED.
2. ALIGN AND PLUMB FIRST WALL PANEL.
3. TO PREVENT "OIL-CANNING", ALL PANEL FASTENERS
SHOULD START FROM BASE MEMBER AND THEN BE
SECURED TO EACH STRUCTURAL GIRT TOWARD THE
EAVE.
4. FOUNDATION MUST BE SQUARE, LEVEL, AND
CORRECT TO THE OUT-TO-OUT STEEL LINE
DIMENSIONS.
5. ERECTION CREW IS TO CLEAN ALL WALL PANELS
BEFORE LEAVING JOB SITE.
6. ERECTOR IS TO ERECT PANELS SO THAT SIDELAPS
ARE AWAY FROM THE MAIN TRAFFIC AREA'S LINE OF
SIGHT.
7. STORE PANELS PROPERLY TO PREVENT MOISTURE.
SEE ERECTION MANUAL.
8. AT FLUSH GIRT CONDITIONS, PRE-DRILL COLUMNS
(& STUBS IF REQ'D) FOR EASE OF PANEL ATTACHMENT
AT THESE AREAS.
9. INSTALL BASE PANEL CLOSURES (IF JOB REQUIRES
THEM). SEE BASE TRIM DETAILS.
H10 STITCH FASTENER
H10 STRUCTURAL FASTENER
H10
12" O.C. AT
TRIM
CORNER
TRIM
EAVE
MEMBER
WALL PANEL
SIDE LAP
GIRTS
H10
AT 30" O.C.
MAXIMUM
(MAY OR MAY
NOT LINE UP
WITH
SUPPORTS)
36"
NET COVERAGE
BASE
MEMBER
ERECTOR NOTE: 1/2" SIDELAP MASTIC (H3010) IS
REQUIRED IN SNOWDRIFT CONDITIONS. REFER TO THE
ELEVATIONS FOR LOCATION REQUIREMENTS.G
A
TRIM_532
GA0000
WALL SHEETING GENERAL NOTES
STEP 1: PLUMB AND SQUARE
THE FIRST STEP IN THE SUCCESSFUL INSTALLATION OF WALL
PANELS IS TO HAVE THE PRIMARY FRAMING PLUMB AND
SQUARE. FOR BEST RESULTS, IT IS RECOMMENDED THAT A
TRANSIT BE USED WHEN ERECTING THE STRUCTURAL STEEL.
MAKE SURE THAT THE FOUNDATION AND BUILDING
STRUCTURE IS SQUARE, LEVEL, AND CORRECT TO THE
OUT-TO-OUT STEEL LINE DIMENSIONS.
SEE FIGURE "A"
STEP 2: GIRT BLOCKING
BLOCK GIRTS TO “LEVEL” POSITION BEFORE STARTING THE
WALL SHEETING OR INSULATION. CHECK TO BE SURE THAT
THE EAVE STRUT AND GIRTS ARE STRAIGHT AND PLUMB. TO
ALIGN THE GIRTS, CUT TEMPORARY WOOD BLOCKING TO THE
PROPER LENGTH AND INSTALL BETWEEN THE LINES OF
GIRTS. THIS BLOCKING CAN BE MOVED FROM BAY TO BAY
WHICH WILL REDUCE THE NUMBER OF PIECES REQUIRED.
NORMALLY, ONE LINE OF BLOCKING PER BAY WILL BE
SUFFICIENT BUT WIDER BAYS MAY REQUIRE MORE. IT IS
RECOMMENDED TO BLOCK AT LEAST TWO BAYS AND LEAP
FROG THE BLOCKING AS A BAY IS SHEETED. BLOCKING
SHOULD NOT BE REMOVED UNTIL THE FULL BAY HAS BEEN
SHEETED.
SEE FIGURE "B"
STEP 3: PRE-DRILL PANEL LAP
STACK PANELS WITH ENDS FLUSH ON A LEVEL PLACE ON THE
GROUND IN PILES NOT EXCEEDING 10 PANELS. THEN PLACE
SMALL WOODEN BLOCKS UNDER SIDE-LAPPING EDGE OF
STACK OF PANELS TO HOLD THEM AT CORRECT HEIGHT AND
POSITION WHILE DRILLING FASTENER HOLES. HOLD PANELS
TIGHTLY TOGETHER AT EACH END WITH CLAMPING PLIERS.
CAREFULLY MARK POSITIONS FOR SIDE-LAP FASTENERS ON
TOP OF HIGH RIB. FASTENERS SHOULD BE LOCATED “ON
CENTER” OF HIGH RIB. DRILL HOLES FOR “STITCH” FASTENER
(USE #1,-7/32” - 15/64” DRILL-BIT) ON TOP SHEET OF SIDE-LAP.
BE SURE PANELS ARE WELL NESTED BEFORE DRILLING.
SEE FIGURE "C"
FASTENER INSTALLATION
RECOMMENDED TOOL TYPES: SEE ALSO FASTENER SCHEDULE
4 AMP OR HIGHER RATED TOOLS (DO NOT USE IMPACTING TOOLS)
2000 - 2500 RPM SCREW GUN WITH TORQUE ADJUSTABLE CLUTCH
MANUAL OR ELECTRIC RIVET TOOL
DO NOT USE IMPACTING TOOLS
TO ASSURE PROPER VOLTAGE TO THE TOOL, EXTENSION CORDS SHOULD BE CHECKED FOR PROPER WIRE
SIZE/CHORD LENGTH.
16 GAGE WIRE, MAXIMUM CHORD LENGTH = 100’
14 GAGE WIRE, MAXIMUM CHORD LENGTH = 200’
12 GAGE WIRE, MAXIMUM CHORD LENGTH = 300’
DRIVING TIPS:
SET THE NUT DRIVER AS DESCRIBED BELOW PRIOR TO INSTALLING FASTENERS TO PREVENT FASTENER WOBBLE...
COMPRESS THE INSULATION AT FASTENER LOCATION WITH ONE HAND WHILE DRIVING THE FASTENER WITH THE
OTHER. THIS WILL HELP KEEP THE PANEL FLAT AND PREVENT THE FASTENER FROM “WALKING”. DRIVE FASTENERS
PERPENDICULAR TO PANEL SURFACE.
EXCESSIVE PRESSURE CAN CAUSE DRILL POINT FAILURE. LET THE FASTENER DO THE WORK.
DO NOT OVER TIGHTEN FASTENERS AS THIS WILL LEAD TO PANEL DIMPLING AND DISTORTION.
PANEL ORIENTATION AND ALIGNMENT
NOTE THE ORIENTATION OF THE PROFILE AND BEARING LEG FOR THE LEADING EDGE OF THE PANEL. PANELS
SHOULD BE INSTALLED AS SHOWN BELOW TO HELP MAINTAIN PANEL MODULARITY / COVERAGE FOR THE LENGTH OF
THE WALL.
PANEL ERECTION
R-PANEL
A-PANEL
REVERSE R-PANEL TUCK PANEL TIGHT TO
THIS CORNER
MAY VARY
MAY VARY
STEEL LINE
STEEL LINE
STEEL LINE
GIRT
BLOCKING (NOT BY
METAL BUILDING
SUPPLIER)
FOUNDATION
FIGURE "C"
BASE TRIM LAP SEALANT
AT BASE TRIM LAPS, APPLY A BEAD OF POLYURETHANE TUBE CAULK (H3152) TO ALL ADJOINING SURFACES AND LAP
1”. SEE BASE TRIM DETAIL FOR THE SPECIFIC TRIM FOR YOUR PROJECT.
IF JOB HAS OPTIONAL FOAM PANEL CLOSURES ORDERED AT BASE, ATTACH TO INSIDE OF WALL PANEL AT BASE AND
FASTEN THROUGH PANEL AND CLOSURE, INTO BASE TRIM. FASTENING PATTERN WILL VARY PER WALL PANEL TYPE.
REFER TO THE WALL PANEL ERECTION DETAIL FOR MORE FASTENING INFO.
USE SUPPLIED BASE CORNER PIECES OR FIELD MITER BASE TRIM AT CORNERS.
INSULATION HINT: AT THE BASE, FOLD THE INSULATION VAPOR BARRIER OVER THE FIBER TO HELP PREVENT WATER
FROM WICKING.
POLYURETHANE
TUBE CAULK
(TYP)
BASE TRIM (NO
FASTENERS
REQ'D AT LAP)
IT IS RECOMMENDED
THAT THE EXPOSED
EDGE OF THE TRIM
LAPS BE CAULKED IN
ORDER TO HELP
PREVENT RUSTING.
BASE
TRIM
FIELD NOTCH THE
"BACK" VERTICAL
LEG OF THE BASE
TRIM 1" AT ALL LAPS
1"
LAP
TUBE CAULK
(APPLY TO ALL
(4) ADJOINING
SURFACES)
1"
LAP
FIELD CUTTING PANELS
WHEN FIELD CUTTING OR MITERING WALL PANELS, NON-ABRASIVE CUTTING TOOLS SUCH AS NIBBLERS OR TIN-SNIPS
SHALL BE USED. ABRASIVE CUTTING TOOLS SUCH AS MECHANICAL GRINDERS OR POWER SAWS CAN DAMAGE THE
MATERIAL FINISH AND CREATE EXCESS METAL SHAVINGS THAT CAN CORRODE THE PANELS. THE USE OF
NON-APPROVED CUTTING DEVICES MAY VOID THE FACTORY WARRANTY.
ANY METAL SHAVINGS THAT ARE CREATED NEED TO BE CLEANED FROM THE PANEL TO PREVENT SCRATCHING
AND/OR CORROSION. THE MANUFACTURER WILL NOT ACCEPT CLAIMS FOR DAMAGE/DETERIORATION DUE TO USE OF
UNAPPROVED TOOLS.
GAP
NO
GAP
1. PUT THE TOP OF THE FASTENER INTO THE NUT
DRIVER. NOTE: FOR PAINTED FASTENERS,
PLACE A SINGLE OR DOUBLED LAYER OF
PLASTIC BETWEEN THE FASTENER HEAD AND
THE NUT DRIVER.
2. PLACE THE POINT OF THE FASTENER ONTO
A HARD SURFACE AND FIRMLY HIT THE TOP OF
THE NUT DRIVER 2-3 TIMES.
4. BAD SET VS. GOOD SET.3. THE BASE OF THE NUT DRIVER SHOULD NOW
BE CONTACTING THE TOP OF THE HEAD OF THE
FASTENER WITH NO GAPS.
BASE TRIM (TRIM PROFILE VARIES
PER PROJECT) ATTACHMENT TO
FOUNDATION IS NOT BY METAL
BUILDING SUPPLIER
GIRT (SPACING
VARIES PER PROJECT)
EAVE FLASH NOT SHOWN FOR
CLARITY. (SEE ERECTION
DRAWING LOW EAVE DETAIL FOR
FASTENER REQUIREMENTS AND
PART NUMBERS)
EAVE STRUT
PANEL ERECTION DETAIL
FOR MARK NUMBER AND
SPACING)
GIRT BLOCKING AS
DESCRIBED IN BUILDING
AND PANEL PREPARATION
STEP 2 (NOT BY METAL
BUILDING SUPPLIER)
3'-0" (PANEL COVERAGE
DRILL BIT
TOP LAP
PRE-DRILLED
TOP PANEL
WOOD BLOCK
FIGURE "A"
EAVE MEMBER
FRAME
FIGURE "B"
PANEL INSTALLATION & FASTENER SEQUENCE
STEP 1: INSTALL FIRST PANEL
INSTALL THE FIRST WALL PANEL AT THE BUILDING CORNER AND ALIGN THE PANEL RIB WITH THE STEEL LINE AS SHOWN
IN THE CORNER DETAILS USING THE START/FINISH DIMENSION SHOWN ON THE PLAN. IT IS EXTREMELY IMPORTANT
THAT THE FIRST WALL PANEL IS INSTALLED PLUMB AND SQUARE. USE A LEVEL OR A TRANSIT TO AID IN THIS PROCESS.
PLACE A 1/8" SHIM ON THE BASE TRIM UNDER THE PANEL TO HOLD THE PANEL OFF THE BASE TRIM. ENSURE THAT THE
WEIGHT OF THE PANEL DOES NOT FORCE BASE TRIM TO EXCESSIVELY BEND DOWN. BASE TRIM SHOULD HAVE A SLIGHT
SLOPE TO ALLOW WATER TO RUN OUT AND NOT SIT ON BASE TRIM.
SEE FIGURE "D" - TO RIGHT
WHEN INSTALLING THE PANEL, APPLY PRESSURE EVENLY TO AVOID DISTORTING THE PANEL AND CAUSING OIL
CANNING.
SEE FIGURE "E" - ABOVE
RECOMMENDED PANEL FASTENING SEQUENCE IS SHOWN TO THE RIGHT. THIS PATTERN AIDS IN PLUMBING AS WELL AS
MAINTAINING PANEL COVERAGE / MODULARITY. SOME APPLICATIONS MAY REQUIRE MODIFIED SEQUENCE AND WILL BE
BEST DETERMINED IN THE FIELD. DO NOT ATTACH PANEL AT BASE AND TOP AND WORK TOWARD THE MIDDLE OF THE
PANEL. THIS CREATES OIL CANNING. MANUFACTURER IS NOT RESPONSIBLE FOR FINAL APPEARANCE OF INSTALLED
PANEL.
STEP 2: INSTALL SUBSEQUENT PANELS
INSTALL THE SECOND PANEL BY LAYING THE LAP EDGE OVER THE BEARING RIB OF THE FIRST PANEL. SEE BELOW FOR
PROPER ALIGNMENT AT SIDE-LAP. CHECK PANEL PLUMBNESS AND FASTEN PANEL IN THE SAME SEQUENCE STARTING
WITH THE STRUCTURAL FASTENERS ALONG THE LAP TO ENSURE A TIGHT SIDE-LAP. CONTINUE FOR THE REMAINDER OF
THE WALL, CUTTING PANELS AROUND FRAMED OPENINGS AS REQUIRED. (TRIM SHOULD BE INSTALLED AROUND
OPENINGS PRIOR TO INSTALLING PANEL)
RECOMMENDED TIPS:
WALL PANELS CAN BE INSTALLED LEFT TO RIGHT OR RIGHT TO LEFT. IT IS RECOMMENDED TO INSTALL SHEETS
STARTING OPPOSITE THE PREVAILING VIEW / WIND SO THAT THE SIDE-LAP SEAM IS AWAY AND LESS NOTICEABLE.
LAP LEG
LAP LEG
BEARING LEG
LAP LEG
BEARING LEG
BEARING LEG
TUCK PANEL TIGHT TO
THIS CORNER
PUSH NEXT TO
MAJOR RIB IN
FLAT OF PANEL
FIGURE "D"
FIGURE "E"
NOTE: BASE TRIM PROFILES ARE MANUFACTURED WITH A 5°D SLOPE TO PROMOTE WATER SHED. ENSURE
SLOPE IS PRESENT TO PREVENT HOLDING WATER. DO NOT ALLOW WEIGHT OF PANEL TO OVER BEND TRIM
CREATING LARGER GAP AT RIB OF PANEL.
CORRECT OVER BENT
SHOWS GAP @ HIGH RIBS
UNDER BENT
HOLDS WATER
7'-6"
(STD)
SHEETING DIRECTION
APPLY EVEN PRESSURE WITH
FOREARM AS SHOWN. DO NOT
CAUSE PANEL TO GROW IN WIDTH.
WALL INSULATION
H1020 / H2200
SUPPLIED @
1'-0" O.C. FOR
INSULATION
TIE-OFF
T hi s se al p er ta in s o n ly to th e m a te ri a ls de si gn ed a nd s u p p lie d b y
N u co r
B ui ld in g S ys te m s, a d iv is io n o f N u co r C or po ra tio n.
T h e d ra w in g s a n d th e m et al b ui ld in g s w h ic h th e y re p re se n t ar e th e pr od u ct o f N u co r
B u ild in g S ys te m s.
T h e r e g is te r p ro fe ss io n a l en gi ne er w ho se s e a l a p p e a rs o n th e se dr aw in gs is e m p lo ye d b y N u co r B ui ld in gs
S ys te m s a n d d o e s n o t s e rv e as o r r ep re se n t t h e p ro je ct e n g in e e r o f re co rd a nd s h a ll n o t b e c o n st ru e d as s u ch
S H
E E
T
IS
S
U E
D W
N C
H K
E N
G P
E D
A T
E P
R O
JE
C
T N
A M
E
C U
S T
O M
E R
N A
M E
JO
B
N U
M B
E R
S H
E E
T T
IT
L
E
D O
F
B
IG
H O
R N
S T
E E
L B
U
IL
D
IN
G S
D B
A R
N R
U L
A
W O
O D
M E
N R
D C
O L
O R
A D
O S
P R
IN
G
S C
O
P U
E B
L O
C
TRIM_547
GENERAL ROOF PANEL NOTES
FASTENER INSTALLATION
RECOMMENDED TOOL TYPES: SEE ALSO FASTENER SCHEDULE
4 AMP OR HIGHER RATED TOOLS (DO NOT USE IMPACTING TOOLS)
2000 - 2500 RPM SCREW GUN WITH TORQUE ADJUSTABLE CLUTCH
MANUAL OR ELECTRIC RIVET TOOL
DO NOT USE IMPACTING TOOLS
TO ASSURE PROPER VOLTAGE TO THE TOOL, EXTENSION CORDS SHOULD BE CHECKED FOR PROPER WIRE
SIZE/CHORD LENGTH.
16 GAGE WIRE, MAXIMUM CHORD LENGTH = 100’
14 GAGE WIRE, MAXIMUM CHORD LENGTH = 200’
12 GAGE WIRE, MAXIMUM CHORD LENGTH = 300’
DRIVING TIPS:
SET THE NUT DRIVER AS DESCRIBED BELOW PRIOR TO INSTALLING FASTENERS TO PREVENT FASTENER WOBBLE...
SOCKET EXTENSIONS (4" OR 6") ARE RECOMMENDED TO BE USED FOR INSTALLING PANEL CLIP FASTENERS TO
MAINTAIN VERTICAL FASTENER INSTALLATION.
EXCESSIVE PRESSURE CAN CAUSE DRILL POINT FAILURE. LET THE FASTENER DO THE WORK.
DO NOT OVER TIGHTEN FASTENERS AS THIS WILL LEAD TO PANEL DIMPLING AND DISTORTION.
GAP
NO
GAP
1. PUT THE TOP OF THE FASTENER INTO THE NUT
DRIVER. NOTE: FOR PAINTED FASTENERS,
PLACE A SINGLE OR DOUBLED LAYER OF
PLASTIC BETWEEN THE FASTENER HEAD AND
THE NUT DRIVER.
2. PLACE THE POINT OF THE FASTENER ONTO
A HARD SURFACE AND FIRMLY HIT THE TOP OF
THE NUT DRIVER 2-3 TIMES.
4. BAD SET VS. GOOD SET.3. THE BASE OF THE NUT DRIVER SHOULD NOW
BE CONTACTING THE TOP OF THE HEAD OF THE
FASTENER WITH NO GAPS.
ROOF PLANE
S T
A R
T P
A N
E L
FULL WIDTH PANELS
"BEARING LEG"
F
IN
IS
H
P A
N E
L
LOW EAVE
LOW EAVE
"BEARING LEG"
FULL WIDTH PANELS
F
IN
IS
H
P A
N E
L
S T
A R
T P
A N
E L
BEARING LEG
1.) THE ROOF SHEETING PLAN IS SHOWN WITH THE ROOF PANELS BEING ERECTED FROM "LEFT-TO-RIGHT".
IF THE DESIRE IS TO ERECT THE ROOF PANELS FROM "LEFT-TO-RIGHT", FOLLOW THE ROOF SHEETING PLAN
AS SHOWN. IF THE DESIRE IS TO ERECT THE ROOF PANELS FROM "RIGHT-TO-LEFT", FOLLOW THE
INSTRUCTIONS SHOWN BELOW.
2.) WHEN SETTING BUNDLES OF PANELS ON THE ROOF, THE "BEARING LEG" MUST ALWAYS BE AWAY FROM
THE END OF THE BUILDING WHERE THE SHEETING WILL BEGIN.
ORIGINAL LAYOUT
(LEFT-TO-RIGHT)
ROTATE PANELS
180°
(RIGHT-TO-LEFT)
ROOF SHEETING DIRECTION
ROOF SYSTEM
THE ROOF SYSTEM CONSISTS OF 24/26 GAUGE PANELS WITH A NOMINAL COVERAGE OF 3'-0" AND A PANEL RIBS THAT
ARE 1 1/4" HIGH AND THROUGH FASTENED ON THE FLAT OF PANEL INTO SECONDARY MEMBERS.
STRUCTURAL FASTENER SPACING REQUIREMENTS
THE ROOF SYSTEM USES STRUCTURAL FASTENERS TO ATTACH THE PANELS TO THE ROOF SECONDARY MEMBERS.
STRUCTURAL FASTENER SPACING REQUIREMENTS ARE SHOWN IN A SEPARATE DETAIL SPECIFIC TO THIS PROJECT.
SIDE LAP FASTENER SPACING REQUIREMENTS
SIDE LAP FASTENERS ARE REQUIRED AT THE SIDELAP OF THE PANELS. THE SPACING OF THESE FASTENERS VARIES
BY DESIGN OF SPECIFIC PROJECT REQUIREMENTS AND MAY VARY IN DIFFERENT AREAS OF THE ROOF. REFERENCE
THE SIDE LAP FASTENER SPACING DETAIL FOR PROJECT SPECIFIC REQUIREMENTS.
ROOF TOP UNITS AND CURB SUPPORTS
THE ROOF CURBS SUPPLIED BY MBS ARE DESIGNED TO BE INSTALLED AFTER THE ROOF PANEL IS INSTALLED.
REFERENCE ROOF CURB INSTALLATION DETAILS IF PROJECT HAS CURBS SUPPLIED BY MBS.
IF CURBS ARE NOT SUPPLIED BY MBS, CARE SHOULD BE TAKEN TO ENSURE WATER TIGHTNESS AND PROPER
INSTALLATION ARE ACHIEVED. MBS IS NOT RESPONSIBLE FOR INSTALLATION DETAILS OR METHODS RELATED TO
CURBS NOT SUPPLIED BY MBS.
INSULATION REQUIREMENTS
INSULATION IS RECOMMENDED TO BE USED IN ALL ROOF APPLICATIONS TO AVOID PROBLEMS WITH CONDENSATION
FORMING ON THE UNDERSIDE OF THE SHEETING. THIS ALSO PROVIDES A BUFFER BETWEEN THE PURLINS AND THE
ROOF TO ELIMINATE NOISE AND POSSIBLE DAMAGE DUE TO METAL-TO-METAL CONTACT.
PAINTED ROOF
PAINTED ROOF PANELS ARE OFTEN PROVIDED BY MBS. IN THIS CASE, GUTTER BRACKETS WILL BE PAINTED TO MATCH
THE ROOF COLOR AS A STANDARD.
SEALING MATERIAL COMPRESSED
UNDER CAP OF FASTENER.
SEALING MATERIAL VISIBLE UNDER
CAP OF FASTENER.
SEALING MATERIAL COMPRESSED
BUT DIMPLED THE PANEL / TRIM.
CORRECT TOO LOOSE TOO TIGHT
2" COMPRESS TO SINGLE
THICKNESS AFTER
LAPPING
MASTIC APPLICATION
TEMPERATURE EXTREMES
TEMPERATURE EXTREMES MUST BE CONSIDERED DURING INSTALLATION OF THE ROOF DUE TO THE SENSITIVITY OF
MASTICS. THE RECOMMENDED INSTALLATION TEMPERATURE RANGE IS 20-120 DEGREES FAHRENHEIT. AT COLDER
TEMPERATURES, THE MASTIC STIFFENS RESULTING IN LOSS OF ADHESION AND COMPRESSIBILITY. AT HOTTER
TEMPERATURES, THE MASTIC BECOMES TOO SOFT FOR PRACTICAL HANDLING. ON COLD BUT SUNNY DAYS, THE
PANEL SURFACE MAY BECOME WARM ENOUGH TO ACCEPT THE APPLICATION OF HEATED MASTIC EVEN THOUGH THE
AIR TEMPERATURE IS BELOW 20 DEGREES FAHRENHEIT.
WHEN OVERNIGHT TEMPERATURES FALL BELOW FREEZING, THE MASTIC SHOULD BE STORED IN A HEATED ROOM SO
IT WILL BE WARM ENOUGH TO USE THE FOLLOWING DAY. ON HOT DAYS, THE MASTIC CARTONS SHOULD BE STORED
OFF THE ROOF IN A COOL AND SHADED AREA. WHILE ON THE ROOF, MASTIC ROLLS SHOULD BE KEPT SHADED UNTIL
ACTUAL USE.
IN VERY COLD WEATHER, IT IS RECOMMENDED THAT THE FASTENERS BE TIGHTENED SLOWLY AND ONLY TIGHT
ENOUGH THAT THE MASTIC IS IN FULL CONTACT WITH THE PANEL OR FLASHING. THEN ON THE NEXT SUNNY DAY, COMPLETE THE TIGHTENING PROCESS AFTER THE SUN WARMS THE PANEL AND FLASHING SURFACES.
CONTAMINATION
TO ASSURE PROPER ADHESION AND SEALING, THE MASTIC MUST HAVE COMPLETE CONTACT WITH ADJOINING
SURFACES. CONTAMINANTS SUCH AS WATER OIL, DIRT AND DUST PREVENT SUCH CONTACT. THE PANEL AND
FLASHING SURFACES MUST BE DRY AND THOROUGHLY CLEANED OF ALL CONTAMINANTS. BEFORE APPLYING TAPE
MASTIC, THE MASTIC SHOULD BE CHECKED FOR CONTAMINANTS. IF THE MASTIC SURFACES ARE CONTAMINATED, IT
MUST NOT BE USED.
DURING COOL WEATHER, CONDENSATION OR LIGHT MIST CAN ACCUMULATE ON THE PANEL AND FLASHING SURFACE
AND NOT BE EASILY NOTICED. IT IS RECOMMENDED THAT THE MASTICS ALWAYS BE KEPT UNDER PROTECTIVE COVER
AND THAT THE PANEL AND FLASHING SURFACES BE WIPED DRY IMMEDIATELY BEFORE INSTALLATION.
TAPE MASTIC IS PROVIDED WITH A PROTECTIVE PAPER TO REDUCE CONTAMINATION. INCOMPLETE REMOVAL OF THE
PROTECTIVE PAPER WILL PREVENT THE MASTIC ADHESION TO THE PANEL OR FLASHING SURFACES. ALWAYS CHECK
THAT THE PROTECTIVE PAPER IS COMPLETELY REMOVED. DO NOT REMOVE THE PROTECTIVE PAPER UNTIL
IMMEDIATELY BEFORE THE PANEL OR FLASHING IS INSTALLED OVER THE MASTIC.
COMPRESSION
TO ASSURE PROPER COMPRESSION AND SEAL, THE TAPE MASTIC MUST BE COMPRESSED BETWEEN THE PANEL AND
FLASHING SURFACES WITH FIRM AND UNIFORM PRESSURE. IN MOST CASES, THE REQUIRED PRESSURE IS APPLIED BY
THE CLAMPING ACTION OF SCREWS PULLING THE ADJOINING SURFACES TOGETHER. HOWEVER, THE TAPE SEALANT’S
RESISTANCE TO PRESSURE BECOMES GREATER IN COLD WEATHER.
DURING COLD WEATHER, THE FASTENERS MUST BE TIGHTENED SLOWLY TO ALLOW THE MASTIC TIME TO COMPRESS.
IF THE FASTENERS ARE TIGHTENED TOO FAST, THE FASTENERS MAY STRIP OUT BEFORE THE MASTIC COMPRESSES
ADEQUATELY, OR THE PANEL OR FLASHING MAY DEFORM IN THE IMMEDIATE AREA OF THE FASTENER, LEAVING THE
REST OF THE MASTIC INSUFFICIENTLY COMPRESSED.
INSIDE CORNERS
AN INSIDE RADIUS, SUCH AS WHERE THE PANEL FLAT MEETS A RIB, IS USUALLY THE MOST CRITICAL AREA TO SEAL. A
COMMON MISTAKE FOR THE INSTALLER IS TO BRIDGE THE MASTIC ACROSS THE INSIDE RADIUS.
WHEN THE LAPPING PANEL OR FLASHING IS PUSHED INTO PLACE, THE BRIDGED MASTIC IS STRETCHED AND THINNED.
THE MASTIC MAY THEN BE TOO THIN TO ADEQUATELY SEAL THIS CRITICAL AREA. WHEN TAPE MASTIC IS APPLIED AT
AN INSIDE RADIUS, IT IS RECOMMENDED THAT THE MASTIC BE FOLDED BACK, THEN PUSH THE MASTIC FOLD INTO THE
RADIUS.
PAPER
BACKING
ARM'S LENGTH
REMOVE PAPER BACKING
ONLY AS WORK PROGRESSES MASTIC LAP
INCORRECT CORRECT
DESIGN AND PERFORMANCE CRITERIA
REGULATIONS
REGULATIONS SET FORTH BY THE OCCUPATIONAL SAFETY AND HEALTH ACT, LOCAL, STATE, AND/OR FEDERAL
AGENCIES SHOULD BE ADHERED TO AT ALL TIMES. MBS IS NOT RESPONSIBLE FOR INJURY, DAMAGE, OR FAILURE, WHICH MAY BE THE RESULT FROM FAILING TO MEET ANY OF THESE REGULATIONS.
IN COMPLIANCE WITH THE HAZARD COMMUNICATION RULE 1910:1200, MATERIAL SAFETY DATA SHEETS (MSDS) HAVE
BEEN PROVIDED FOR YOUR USE AND SAFETY. THESE DATA SHEETS SHOULD BE MADE AVAILABLE TO ALL PERSONNEL
THAT COME IN CONTACT WITH THESE PRODUCTS. THESE DATA SHEETS WILL GIVE YOU THE NECESSARY
INFORMATION TO PROPERLY HANDLE SUCH MATERIALS AND WHAT TO DO IN CASE OF AN EMERGENCY. (THE MSDS
SHEETS ARE LOCATED ONLINE AND ARE AVAILABLE UPON REQUEST).
THE ERECTOR OF THE ROOF SYSTEM IS RESPONSIBLE FOR THE SAFE EXECUTION OF THIS DETAIL. THESE
INSTRUCTIONS ARE INTENDED TO DESCRIBE THE SEQUENCE AND PROPER PLACEMENT OF PARTS. THEY ARE NOT
INTENDED TO PRESCRIBE COMPREHENSIVE SAFETY PROCEDURES. THE PROCEDURES IN THIS DETAIL ARE BELIEVED
TO BE RELIABLE. HOWEVER, MBS SHALL NOT BE RESPONSIBLE FOR INJURY, DAMAGE, OR FAILURE DUE TO THE
MISAPPLICATION OF THESE PROCEDURES, IMPROPER ERECTION TECHNIQUES, OR NEGLIGENCE
WALKING AND WORKING ON ROOF PANELS
DO NOT PLACE BUNDLES OF PANELS ON THE ROOF STRUCTURE WITHOUT FIRST VERIFYING THE STRUCTURE WILL
SAFELY SUPPORT THE CONCENTRATED WEIGHT OF THE PANELS AND THE WEIGHT OF THE INSTALLATION CREW.
SOME ROOF STRUCTURES MAY NOT BE DESIGNED TO SUPPORT THE WEIGHT OF A FULL PANEL BUNDLE WITHOUT
ADDITIONAL STRUCTURE SUPPORT.
DO NOT USE A ROOF PANEL AS A WORKING PLATFORM. AN UNSECURED PANEL COULD COLLAPSE UNDER THE
WEIGHT OF A PERSON STANDING BETWEEN PURLINS OR AT THE PANEL END.
DO NOT WALK ON THE LAST INSTALLED PANEL RUN, AS THE UNSECURED EDGE COULD COLLAPSE UNDER A PERSON’S
WEIGHT. WHEN INSTALLING PANELS OR MAKING END LAP CONNECTIONS, ETC., STAND WHERE THE ROOF
STRUCTURAL WILL SUPPORT YOUR WEIGHT.
AN APPROVED AND SAFE WALKING PLATFORM SHOULD BE USED IN HIGH TRAFFIC AREAS TO PREVENT THE ROOF
PANEL FROM BEING DEFORMED, SCRATCHED, OR SCUFFED.
SAFETY EQUIPMENT
THE USE OF SAFETY EQUIPMENT FOR THE ROOF PANEL INSTALLATION IS RECOMMENDED AT ALL TIMES DURING THE
INSTALLATION PROCESS. HOWEVER, WHEN USING LANYARDS, ENSURE THAT THE CLASP, BELT HOOKS AND WIRE
CABLES ARE COVERED IN SUCH A MANNER THAT THEY WILL NOT SCRATCH THE PANEL SURFACE IF ACCIDENTALLY
DRAGGED ALONG THE PANEL.
CREW SIZE
THE LENGTH OF THE INDIVIDUAL ROOF PANELS SHOULD BE CONSIDERED WHEN DETERMINING CREW SIZE. IT IS
RECOMMENDED THAT UNDER NORMAL CONDITIONS, THERE BE ONE PERSON FOR EVERY TEN FEET OF PANEL LENGTH, PLUS ONE.
PANEL OVERHANG
DO NOT STAND ON THE END OF UNSUPPORTED (CANTILEVERED) PANELS AT THE EAVE OR RIDGE. STANDING ON THE
CANTILEVER PORTION MAY RESULT IN PANEL COLLAPSE.
POINT LOADS
WHEN PROPERLY SUPPORTED BY THE STRUCTURAL STEEL, PANELS ARE DESIGNED TO SUPPORT UNIFORM LOADS, WHICH ARE EVENLY DISTRIBUTED OVER THE PANEL SURFACES. POINT LOADS THAT OCCUR IN SMALL OR
CONCENTRATED AREAS, SUCH AS HEAVY EQUIPMENT, LADDER, OR PLATFORM FEET, ETC., MAY CAUSE PANEL
DEFORMATION OR EVEN PANEL COLLAPSE.
SLICK SURFACES
PANEL SURFACES AND STRUCTURAL STEEL SURFACES ARE HARD, SMOOTH, AND NONABSORBENT, WHICH CAUSES
THESE SURFACES TO BE VERY SLICK WHEN WET OR COVERED WITH SNOW OR ICE. EVEN BLOWING SAND OR HEAVY
DUST CAN MAKE THESE SURFACES DIFFICULT TO WALK ON WITHOUT SLIPPING.
UNPAINTED PANEL SURFACES ARE OFTEN COATED WITH OIL TO ACCOMMODATE THE PANEL-FABRICATION PROCESS.
ALTHOUGH DESIGNED TO WASH AWAY OR EVAPORATE DURING NORMAL WEATHER, THE OIL ON NEW PANELS CAN BE
EXTREMELY SLICK, ESPECIALLY DURING PERIODS OF LIGHT RAIN AND DEW.
CAUTION MUST BE EXERCISED TO PREVENT SLIPPING AND FALLING ONTO THE ROOF SURFACE OR EVEN SLIDING OFF
THE ROOF. NON-SLIP FOOTWEAR IS A NECESSITY AND NON-SLIP WORKING PLATFORMS ARE RECOMMENDED.
ELECTRICAL CONDUCTANCE
METAL PANELS ARE EXCELLENT ELECTRICAL CONDUCTORS. A COMMON CAUSE OF INJURY IS THE CONTACT OF
METAL PANELS WITH POWER LINES DURING HANDLING AND INSTALLATION. THE LOCATION OF ALL POWER LINES MUST
BE NOTED AND, IF POSSIBLE, FLAGGED. THE INSTALLATION PROCESS MUST BE ROUTED TO AVOID ACCIDENTAL
CONTACT WITH ALL POWER LINES AND HIGH VOLTAGE SERVICES AND EQUIPMENT. ALL TOOLS AND POWER CORDS
MUST BE PROPERLY INSULATED AND GROUNDED AND THE USE OF APPROVED GROUND FAULT CIRCUIT BREAKERS IS
RECOMMENDED.
FALSE SECURITY OF INSULATION
BLANKET AND RIGID BOARD INSULATION BLOCK THE INSTALLER’S VIEW OF THE GROUND BELOW THE ROOF. SERIOUS
INJURY CAN OCCUR WHEN THE INSTALLER GETS A FALSE SENSE OF SECURITY BECAUSE HE CANNOT SEE THE
GROUND AND STEPS THROUGH THE INSULATION.
SHARP EDGES
SOME EDGES OR PANELS AND FLASHING ARE RAZOR SHARP AND CAN CAUSE SEVERE CUTS IF PROPER PROTECTIVE
HAND GEAR IS NOT WORN. BE CAREFUL NOT TO INJURE OTHERS WHILE MOVING PANELS AND FLASHING.
COORDINATION WITH OTHER TRADES
SUPPORTS FOR THE ROOF SYSTEM SHALL BE PROVIDED AND ARE REQUIRED AS SHOWN IN THE SECTIONS AND AS
NOTED IN THESE SPECIFICATIONS. ALL NECESSARY CLEARANCE DIMENSIONS FOR PROPER ELEVATIONS RELATIVE TO
THE ROOF PANELS HAVE BEEN SHOWN. THE ERECTOR SHALL BE RESPONSIBLE FOR COORDINATING THESE
DIMENSIONAL REQUIREMENTS WITH OTHER TRADES ASSOCIATED WITH THE BUILDING ROOF SYSTEM.
ERECTION CARE
THE ERECTOR MUST BE SKILLED IN THE ERECTION OF METAL BUILDING SYSTEMS AND IS RESPONSIBLE FOR
COMPLYING WITH ALL APPLICABLE LOCAL, FEDERAL AND STATE CONSTRUCTION AND SAFETY REGULATIONS
INCLUDING OSHA REGULATIONS AS WELL AS ANY APPLICABLE REQUIREMENTS OF LOCAL, NATIONAL OR
INTERNATIONAL UNION RULES OR PRACTICES. THE ERECTOR REMAINS SOLELY RESPONSIBLE FOR THE SAFETY AND
APPROPRIATENESS OF ALL TECHNIQUES AND METHODS UTILIZED BY ITS CREWS IN THE ERECTION OF THE METAL
BUILDING SYSTEM AND/OR THE ROOF SYSTEM. THE ERECTOR IS ALSO RESPONSIBLE FOR SUPPLYING ANY SAFETY
DEVICES SUCH AS SCAFFOLDS, RUNWAYS, NETS, ETC. WHICH MAY BE REQUIRED TO SAFELY ERECT THE METAL
BUILDING SYSTEM AND/OR ROOF SYSTEM.
THE ERECTOR OF THE ROOF SYSTEM SHALL EXERCISE GREAT CARE AND ATTENTION TO THE DETAILS AS SHOWN ON
THESE DRAWINGS TO INSURE A SECURE AND PROPER FIT OF ALL COMPONENTS. MBS SHALL NOT BE RESPONSIBLE
FOR SUPERVISING AND/OR COORDINATING THE ERECTION OF THE ROOF SYSTEM WITH OTHER TRADES.
DUE CONSIDERATION MUST BE GIVEN BY THE ERECTOR TO THE EFFECTS OF THERMAL EXPANSION AND
CONTRACTION WHEN ERECTING A ROOF TIE-IN TO AN EXISTING STRUCTURE TO INSURE A SAFE, SECURE, WEATHERTIGHT…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .