B D LINE DRAWING.pdf

PDF 8 MB Posted

Attached to
Corrosion Control System Upgrades
Solicitation number
OP138382(2)
Issued by
California

About this file

This file is a technical drawing set for cathodic protection system installations on the Los Angeles County Metropolitan Transportation Authority's (LACMTA) Red Line B and D passenger rail lines. The project encompasses corrosion control installations across multiple passenger stations (North Hollywood, Universal City, Hollywood/Highland, Hollywood/Vine, Hollywood/Western, Vermont/Sunset, Vermont/Santa Monica, Vermont/Beverly, Wilshire/Western, Wilshire/Normandie, Wilshire/Vermont, Westlake/MacArthur Park, 7th Street/Metro Center, Pershing Square, Civic Center, and Union Station), Division 20 Yard facility, and associated maintenance divisions. The scope of work includes installation of new magnesium anodes, replacement of shunts and reference electrodes, location and repair of existing test stations and wiring, installation of electrical isolation devices at fire pits, and pipe insulation details at specified locations. The drawings are dated October 30, 2024, with contract number PS46172000, and are financed in part through a Federal Transit Administration grant under the Federal Transit Act of 1964 and Los Angeles County and State of California tax revenues.

The project specifications require adherence to NACE (National Association of Corrosion Engineers) standards and California Code of Regulations Title Eight for excavation work. All trenching operations require 48-hour advance notification to Underground Service Alert (USA) 811 and field verification of utility locations through potholing. High-potential magnesium anodes are specified at 48 pounds ingot weight with defined chemical composition, installed in packaged backfill consisting of 75% gypsum, 20% bentonite, and 5% sodium sulfate. All contractors must obtain required CalOSHA permits for excavations five feet or deeper and secure encroachment permits from relevant local authorities before beginning field installation. Excess excavated soil must be properly disposed of, and disturbed surface areas must be restored to near pre-construction conditions to facilitate drainage and prevent ponding.

View the file

Other files

File Type Posted
IFB No. OP138382(2).pdf PDF
EXHIBIT B - PRICING AGREEMENT.pdf PDF
EXHIBIT F - RELEASE OF CLAIMS.pdf PDF
EXHIBIT H - DELIVERABLES AND PAYMENT SCHEDULE.pdf PDF
E LINE DRAWING.pdf PDF
EXHIBIT 15 - BID BOND.pdf PDF
EXHIBIT 7 - LIST OF COMPLETED CONTRACTS - LAST FIVE (5) YEARS.pdf PDF
EXHIBIT 5 - BID LETTER.pdf PDF
SUBCONTRACTOR LISTING FORM.pdf PDF
EXHIBIT E-1 - PAYMENT CERTIFICATION (CONTINUOUS).pdf PDF
EXHIBIT A - SOW 7.23.26.pdf PDF
A LINE DRAWING.pdf PDF
EXHIBIT 12 - MINIMUM QUALIFICATIONS.pdf PDF
FORM 3 - BUSINESS DATA SHEET.pdf PDF
FORM 1 - SBE-DVBE SUBS & SUPPLIERS.pdf PDF
FORM 6 - SBE-DVBE DEALER-DISTR AFFIRMATION.pdf PDF
FORM 4 - SBE-DVBE AFFIRMATION.pdf PDF
EXHIBIT C - LIQUIDATED DAMAGES.pdf PDF
EXHIBIT E-2 - PAYMENT CERTIFICATION (FINAL).pdf PDF
C LINE DRAWING.pdf PDF
EXHIBIT 8 - ETHICS DECLARATION.pdf PDF
EXHIBIT 11 - NONCOLLUSION AFFIDAVIT TO BE EXECUTED BY BIDDER.pdf PDF
EXHIBIT 9 - GENERAL CERTIFICATIONS.pdf PDF
FORM 5 - BIDDERS LIST FORM.pdf PDF
EXHIBIT 13 - CERTIFICATION OF PROSPECTIVE CONTRACTOR.pdf PDF
EXHIBIT 16 PERFORMANCE AND PAYMENT BOND.pdf PDF
EXHIBIT G - APPROVED SUBCONTRACTORS AND SUPPLIERS.pdf PDF
EXHIBIT D - DEOD CONTRACT COMPLIANCE MANUAL (Non-Fed).pdf PDF
EXHIBIT 10 - CERTIFICATE OF COMPLIANCE WITH 49 CFR PART 655.pdf PDF
FORM 2 - AFFIDAVIT.pdf PDF
EXHIBIT 3 - RESERVED.pdf PDF
EXHIBIT 4 - LIST OF CERTIFIED FIRMS.pdf PDF
EXHIBIT 2 - SCHEDULE OF QUANTITIES AND PRICES.pdf PDF
EXHIBIT 6 - LIST OF CURRENT CONTRACTS - BACKLOG.pdf PDF
EXHIBIT 14 -PUBLIC WORKS VERIFICATION FORM.pdf PDF
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

METRO MAINTENANCE AND BUS DIVISIONS

BUILDING ADDRESS

DIVISION 2 720 E. 15TH ST., LOS ANGELES 90021

DIVISION 3 630 W. AVENUE 28, LOS ANGELES 90065

DIVISION 4 7878 TELEGRAPH RD., DOWNEY 90240

DIVISION 5 1130 VAN NESS AVE., LOS ANGELES 90062

DIVISION 7 8800 SANTA MONICA BLVD., WEST HOLLYWOOD 90069

DIVISION 8 9201 CANOGA AVE., CHATSWORTH 91311

DIVISION 9 3449 SANTA ANITA AVE., EL MONTE 91731

DIVISION 10 742 N. MISSION ROAD, LOS ANGELES 90033

DIVISION 15 11900 BRANDFORD ST., SUN VALLEY 91352

DIVISION 18 450 W. GRIFFITH ST., GARDENA 90248

LOCATION 29 706 E. 15TH ST., LOS ANGELES 90021

LOCATION 122 2100 FRANK MODUGNO RD., SYLMAR 91340

LOCATION 123 10036 OLD DEPOT PLAZA RD., CHATSWORTH 91311

CATHODIC PROTECTION SHEET INDEX

SHEET

NUMBER SHEET NAME

CP-00 COVER SHEET AND SHEET INDEX

CP-01 B/D LINES - OVERALL ALIGNMENT

CP-02 B/D LINES - PASSENGER STATIONS I

CP-03

CP-04

CP-05

CP-06

CP-07

CP-08

CP-09

CP-10

CP-11

DIVISION 1 1130 E. 6TH ST., LOS ANGELES 90021

B/D LINES - CATHODIC PROTECTION DETAILS I

ABBREVIATIONS

ABV.

SHEET NAME

CP CATHODIC PROTECTION

NACE NATIONAL ASSOCIATION OF CORROSION ENGINEERS

IFK INSULATION FLANGE KIT

GENERAL NOTES:

1. TRENCHING AND EXCAVATION NOTES:

a. THE UTILITY LOCATIONS ON THE DRAWINGS ARE APPROXIMATE AND SHALL BE

USED FOR REFERENCE ONLY. UTILITY LOCATIONS AND ALL OTHER

SUBSTRUCTURES SHALL BE FIELD VERIFIED BY POTHOLING.

b. DELINEATE WORK AREA AND CALL THE APPROPRIATE UNDERGROUND SERVICE

ALERT (USA) 811, 48 HOURS (NOT INCLUDING INITIAL DAY) PRIOR TO START OF

WORK.

c. TRENCH LIMITATIONS WILL BE GOVERNED BY THE PERMITTING AGENCY.

d. NOTIFY THE LOCAL DISTRICT CONTACT AND THE REGION'S ENVIRONMENT

SPECIALIST IF CONTAMINATED SOIL IS ENCOUNTERED OR SUSPECTED.

e. ALL EXCAVATIONS SHALL BE IN ACCORDANCE WITH TITLE EIGHT (8) OF THE

CALIFORNIA CODE OF REGULATIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR THE

REQUIRED CALOSHA PERMIT FOR EXCAVATIONS OR TRENCHES FIVE (5) FEET IN DEPTH OR

GREATER.

2. CATHODIC PROTECTION NOTES:

a. ANODES SHALL BE FIELD LOCATED AS DEEMED NECESSARY AND CLEAR FROM ANY

EXISTING BURIED UTILITIES/STRUCTURES/CABLES.

b. ANODE CABLES ARE TO BE INSTALLED AND SECURED WITHOUT DAMAGE TO THE

INSULATION

3. LOOSE EXCAVATED MATERIAL SHALL NOT BE PLACED OR STORED IN WATERWAYS OR

STORM DRAIN CHANNELS. ALL EXCESS EXCAVATED SOIL AND MATERIALS SHALL BE

REMOVED AND DISPOSED OF IN A PROPER AND LEGAL MANNER BY THE CONTRACTOR. ALL

DISTURBED SURFACE AREAS SHALL BE SHAPED TO FACILITATE DRAINAGE AND AVOID

PONDING AND RESTORED TO NEAR NATURAL OR PRE-CONSTRUCTION CONDITIONS.

4. INFORMATION ON EXISTING UTILITIES AND OTHER SUBSTRUCTURES SHALL BE OBTAINED

FROM THE APPROPRIATE AGENCIES. ALL CONSTRUCTION SHALL BE DONE A MINIMUM 48

HOURS AFTER USA DIG CALL ALERTS HAVE BEEN MADE AND USA DIG HAS CLEARED THE

AREA.

5. ADEQUATE SAFETY MEASURES SHALL BE MAINTAINED BY THE PROPER SCHEDULING OF THE

INSTALLATIONS, PAVEMENT RECONSTRUCTION, APPROVED TRAFFIC CONTROL DEVICES (AS

REQUIRED) AND IN ACCORDANCE WITH SECURED OR PROVIDED PERMITS FROM RELEVANT

LOCAL AUTHORITIES HAVING JURISDICTION.

6. ALL CONSTRUCTION SHALL CONFORM TO NACE STANDARDS AND PROJECT SPECIFICATIONS,

AND SHALL BE AS PER APPROVED DRAWINGS. ALL THE PROPER ENCROACHMENT PERMITS

AS REQUIRED BY THE DISTRICT OR LOCAL AUTHORITY HAVING JURISDICTION MUST BE MET

BEFORE BEGINNING THE FIELD INSTALLATION.

REF REFERENCE ELECTRODE

CP-12

CP-13

CP-14

CP-15

CP-16

CP-17

CP-18

B/D LINES - CATHODIC PROTECTION DETAILS II

B/D LINES - CATHODIC PROTECTION DETAILS III

B/D LINES - EQUIPMENT SCHEDULE I

B/D LINES - PASSENGER STATIONS II

B/D LINES - PASSENGER STATIONS III

B/D LINES - PASSENGER STATIONS IV

B/D LINES - PASSENGER STATIONS V

B/D LINES - PASSENGER STATIONS VI

B/D LINES - PASSENGER STATIONS VII

B/D LINES - PASSENGER STATIONS VIII

B/D LINES - DIVISION 20 YARD LAYOUT

B/D LINES - FIRE PIT DETAILS I

B/D LINES - FIRE PIT DETAILS II

B/D LINES - FIRE PIT DETAILS III

B/D LINES - FIRE PIT DETAILS IV

CNL COULD NOT LOCATE

CP-19

B/D LINES - STATION PIPE INSULATION DETAILS

B/D LINES - EQUIPMENT SCHEDULE IICP-20

10/30/24

L. PEDERSON

E. JOHNSON

L. PEDERSON/E. JOHNSON B-D LINES

IN CHARGE

CHECKED BY

SCALE

DRAWN BY

DESIGNED BY

S. SINGH

DATE:

THE PREPARATION OF THIS

DRAWING HAS BEEN FINANCED IN

PART THROUGH A GRANT FROM

THE U.S. DEPARTMENT OF

TRANSPORTATION, FEDERAL TRANSIT

ADMINISTRATION (FTA), UNDER THE

FEDERAL TRANSIT ACT OF 1964, AS

AMENDED, AND IN PART BY THE

TAXES OF THE CITIZENS OF

LOS ANGELES COUNTY AND OF

THE STATE OF CALIFORNIA.

SHEET NO

REV DATE BY APP REG NO. EXPIRES SEAL HOLDER DESCRIPTION

CORROSION CONTROL

DRAWING NO

CONTRACT NO

REV

601 S. FIGUEROA ST. SUITE 3800

LOS ANGELES, CA 90017

PS46172000

AS INDICATED

LOS ANGELES COUNTY

METROPOLITAN TRANSPORTATION AUTHORITY

23309 LA PALMA AVE YORBA LINDA, CA 92887

COVER SHEET AND SHEET INDEX

IC

EPSNOITCETORPCI

OHTAC

ECA N

N A C E I N T E R N AT I O

HGNISJVRAS

No. 6125

D

TS

IL

A

TI

N AL

EXP. 05/07/25

CP-00

BUILDING ADDRESS

DIVISION 20 320 S SANTA FE AVE, LOS ANGELES CA 90013

PASSENGER LINE B

PASSENGER LINE D

10/30/24

L. PEDERSON

E. JOHNSON

L. PEDERSON/E. JOHNSON B-D LINES

IN CHARGE

CHECKED BY

SCALE

DRAWN BY

DESIGNED BY

S. SINGH

DATE:

THE PREPARATION OF THIS

DRAWING HAS BEEN FINANCED IN

PART THROUGH A GRANT FROM

THE U.S. DEPARTMENT OF

TRANSPORTATION, FEDERAL TRANSIT

ADMINISTRATION (FTA), UNDER THE

FEDERAL TRANSIT ACT OF 1964, AS

AMENDED, AND IN PART BY THE

TAXES OF THE CITIZENS OF

LOS ANGELES COUNTY AND OF

THE STATE OF CALIFORNIA.

SHEET NO

REV DATE BY APP REG NO. EXPIRES SEAL HOLDER DESCRIPTION

CORROSION CONTROL

DRAWING NO

CONTRACT NO

REV

601 S. FIGUEROA ST. SUITE 3800

LOS ANGELES, CA 90017

PS46172000

AS INDICATED

LOS ANGELES COUNTY

METROPOLITAN TRANSPORTATION AUTHORITY

23309 LA PALMA AVE YORBA LINDA, CA 92887

OVERALL ALIGNMENT

IC

EPSNOITCETORPCI

OHTAC

ECA N

N A C E I N T E R N AT I O

HGNISJVRAS

No. 6125

D

TS

IL

A

TI

N AL

EXP. 05/07/25

CP-01

DIVISION 20 YARD

SEE SHEET CP-10

NORTH HOLLYWOOD STATION

SEE SHEET CP-02

UNIVERSAL CITY STATION

SEE SHEET CP-02

HOLLYWOOD/HIGHLAND

STATION, SEE SHEET CP-03

HOLLYWOOD/VINE

STATION, SEE SHEET CP-03

HOLLYWOOD/WESTERN

STATION, SEE SHEET CP-04

VERMONT/SUNSET

STATION, SEE SHEET CP-04

VERMONT/SANTA MONICA

STATION, SEE SHEET CP-05

VERMONT/BEVERLY

STATION, SEE SHEET CP-05

WILSHIRE/WESTERN

STATION, SEE SHEET CP-07

WILSHIRE/NORMANDIE

STATION, SEE SHEET CP-06 WILSHIRE/VERMONT

STATION, SEE SHEET CP-06

WESTLAKE/MACARTHUR PARK

STATION, SEE SHEET CP-07

7TH STREET/METRO CENTER

STATION, SEE SHEET CP-08

PERSHING SQUARE

STATION, SEE SHEET CP-08

CIVIC CTR/GRAND PARK

STATION, SEE SHEET CP-09

UNION STATION

SEE SHEET CP-09

10/30/24

L. PEDERSON

E. JOHNSON

L. PEDERSON/E. JOHNSON B-D LINES

IN CHARGE

CHECKED BY

SCALE

DRAWN BY

DESIGNED BY

S. SINGH

DATE:

THE PREPARATION OF THIS

DRAWING HAS BEEN FINANCED IN

PART THROUGH A GRANT FROM

THE U.S. DEPARTMENT OF

TRANSPORTATION, FEDERAL TRANSIT

ADMINISTRATION (FTA), UNDER THE

FEDERAL TRANSIT ACT OF 1964, AS

AMENDED, AND IN PART BY THE

TAXES OF THE CITIZENS OF

LOS ANGELES COUNTY AND OF

THE STATE OF CALIFORNIA.

SHEET NO

REV DATE BY APP REG NO. EXPIRES SEAL HOLDER DESCRIPTION

CORROSION CONTROL

DRAWING NO

CONTRACT NO

REV

601 S. FIGUEROA ST. SUITE 3800

LOS ANGELES, CA 90017

PS46172000

AS INDICATED

LOS ANGELES COUNTY

METROPOLITAN TRANSPORTATION AUTHORITY

23309 LA PALMA AVE YORBA LINDA, CA 92887

PASSENGER STATIONS I

IC

EPSNOITCETORPCI

OHTAC

ECA N

N A C E I N T E R N AT I O

HGNISJVRAS

No. 6125

D

TS

IL

A

TI

N AL

EXP. 05/07/25

CP-02

CP-02

NORTH HOLLYWOOD STATION

SCALE: NOT TO SCALE

SYMBOL CP EQUIPMENT REFERENCE DETAIL

EXISTING TEST

STATION -

TEST POINT -

PROPOSED TEST

STATION CP-16 / DETAIL 1

CP-02

UNIVERSAL CITY STATION

SCALE: NOT TO SCALE

NORTH HOLLYWOOD STATION

TEST STATION LOCATION ACTION

NEEDED REQUIREMENTS

1 STREET LEVEL NO N/A

2 STREET LEVEL YES INSTALL NEW ANODES (2)

3 STREET LEVEL YES REPLACE SHUNT (1)

4 STREET LEVEL NO N/A

5 STREET LEVEL YES REPLACE SHUNT (1)

6 STREET LEVEL NO N/A

7 STREET LEVEL YES EXCAVATE AND LOCATE WIRES

8 STREET LEVEL NO N/A

9 STREET LEVEL NO N/A

10 STREET LEVEL YES INSTALL NEW ANODES (2)

16 INJECTOR ROOM S-212 NO N/A

17 INJECTOR ROOM S-212 NO N/A

ELEVATOR #1 ROOM S-204 YES REPLACE REFERENCE ELECTRODE (1)

ELEVATOR #2 ROOM D-110 YES INSTALL NEW ANODES (2)

NORTH FIRE PIT STREET LEVEL YES INSTALL ELECTRICAL ISOLATION (2)

SOUTH FIRE PIT STREET LEVEL YES INSTALL ELECTRICAL ISOLATION (1)

UNIVERSAL CITY STATION

TEST STATION LOCATION ACTION

NEEDED REQUIREMENTS

1 STREET LEVEL YES INSTALL NEW ANODES (2)

2 STREET LEVEL NO N/A

3 STREET LEVEL NO N/A

4 STREET LEVEL YES INSTALL NEW ANODES (2)

5 STREET LEVEL NO N/A

6 STREET LEVEL YES INSTALL NEW ANODES (2)

7 STREET LEVEL YES INSTALL NEW ANODES (2)

8 STREET LEVEL YES INSTALL NEW ANODES (2)

9 STREET LEVEL YES LOCATE TEST STATION

IJ BOX AUX POWER ROOM

E-306 NO N/A

IJ BOX (DCW) AUX POWER ROOM

E-306 YES INSTALL ELECTRICAL ISOLATION (1)

IJ BOX

(DISCHARGE)

AUX POWER ROOM

E-306 NO N/A

IJ BOX SPRINKLER VALVE

ROOM C-212 NO N/A

ELEVATOR #1 ROOM 208 YES INSTALL NEW ANODES (2) AND REFERENCE ELECTRODE (1)

ELEVATOR #2 ROOM C-110 YES

INSTALL NEW TEST STATION, INSTALL NEW ANODES (2) AND

REFERENCE ELECTRODE (1)

ELEVATOR #3 ROOM 208 NO N/A

NORTH FIRE PIT STREET LEVEL YES INSTALL ELECTRICAL ISOLATION (1)

SOUTH FIRE PIT STREET LEVEL NO N/A

AutoCAD SHX Text T

L. PEDERSON

E. JOHNSON

L. PEDERSON/E. JOHNSON B-D LINES

IN CHARGE

CHECKED BY

SCALE

DRAWN BY

DESIGNED BY

S. SINGH

DATE:

THE PREPARATION OF THIS

DRAWING HAS BEEN FINANCED IN

PART THROUGH A GRANT FROM

THE U.S. DEPARTMENT OF

TRANSPORTATION, FEDERAL TRANSIT

ADMINISTRATION (FTA), UNDER THE

FEDERAL TRANSIT ACT OF 1964, AS

AMENDED, AND IN PART BY THE

TAXES OF THE CITIZENS OF

LOS ANGELES COUNTY AND OF

THE STATE OF CALIFORNIA.

SHEET NO

REV DATE BY APP REG NO. EXPIRES SEAL HOLDER DESCRIPTION

CORROSION CONTROL

DRAWING NO

CONTRACT NO

REV

601 S. FIGUEROA ST. SUITE 3800

LOS ANGELES, CA 90017

PS46172000

AS INDICATED

LOS ANGELES COUNTY

METROPOLITAN TRANSPORTATION AUTHORITY

23309 LA PALMA AVE YORBA LINDA, CA 92887

PASSENGER STATIONS II

IC

EPSNOITCETORPCI

OHTAC

ECA N

N A C E I N T E R N AT I O

HGNISJVRAS

No. 6125

D

TS

IL

A

TI

N AL

EXP. 05/07/25

CP-03

CP-03

HOLLYWOOD/HIGHLAND STATION

SCALE: NOT TO SCALE

SYMBOL CP EQUIPMENT REFERENCE DETAIL

EXISTING TEST

STATION -

TEST POINT -

PROPOSED TEST

STATION CP-16 / DETAIL 1

CP-03

HOLLYWOOD/VINE STATION

SCALE: NOT TO SCALE

HOLLYWOOD/HIGHLAND STATION

TEST STATION LOCATION ACTION

NEEDED REQUIREMENTS

1 STREET LEVEL NO N/A

2 STREET LEVEL YES INSTALL NEW ANODES (2)

3 STREET LEVEL YES INSTALL NEW ANODES (2)

4 STREET LEVEL YES INSTALL NEW ANODES (2)

5 STREET LEVEL YES INSTALL NEW ANODES (3)

6 STREET LEVEL YES INSTALL NEW ANODES (4)

7 STREET LEVEL YES INSTALL NEW ANODES (4)

8 STREET LEVEL YES INSTALL NEW ANODES (2)

9 STREET LEVEL YES INSTALL NEW ANODES (2)

10 STREET LEVEL NO N/A

11 STREET LEVEL YES INSTALL NEW ANODES (2)

12 STREET LEVEL YES LOCATE MISSING TEST STATION

13 STREET LEVEL YES INSTALL NEW ANODES (4)

14 STREET LEVEL YES INSTALL NEW ANODES (4)

IJ BOX (FDW) NO N/A

IJ BOX (DCW) WEST END DWP NO N/A

ELEVATOR #1 ROOM S-208 YES REPAIR WIRES/CONNECTION TO CYLINDER

ELEVATOR #2 AR TRACK WEST

PLATFORM ? ?

NORTH FIRE PIT STREET LEVEL NO N/A

SOUTH FIRE PIT STREET LEVEL NO N/A

HOLLYWOOD/VINE STATION

TEST STATION LOCATION ACTION

NEEDED REQUIREMENTS

1 STREET LEVEL YES INSTALL NEW ANODE (1), INSTALL SHUNT (1)

2 STREET LEVEL YES REPLACE SHUNT (1)

3 STREET LEVEL NO N/A

4 STREET LEVEL YES LOCATE MISSING TEST STATION

5 STREET LEVEL YES REPLACE SHUNT (1)

6 STREET LEVEL YES REPLACE TEST STATION BOX COVER

7 STREET LEVEL YES LOCATE MISSING TEST STATION

8 STREET LEVEL YES REPLACE SHUNT (1)

9 STREET LEVEL YES LOCATE MISSING TEST STATION

10 STREET LEVEL YES LOCATE MISSING TEST STATION

11 INJECTOR ROOM S-212 YES LOCATE MISSING TEST STATION

IJ BOX (FP) MECH ROOM 60 NO N/A

ELEVATOR #1 ROOM 75 NO N/A

ELEVATOR #2 R Track West NO N/A

EAST FIRE PIT STREET LEVEL NO N/A

WEST FIRE PIT STREET LEVEL NO N/A

L. PEDERSON

E. JOHNSON

L. PEDERSON/E. JOHNSON B-D LINES

IN CHARGE

CHECKED BY

SCALE

DRAWN BY

DESIGNED BY

S. SINGH

DATE:

THE PREPARATION OF THIS

DRAWING HAS BEEN FINANCED IN

PART THROUGH A GRANT FROM

THE U.S. DEPARTMENT OF

TRANSPORTATION, FEDERAL TRANSIT

ADMINISTRATION (FTA), UNDER THE

FEDERAL TRANSIT ACT OF 1964, AS

AMENDED, AND IN PART BY THE

TAXES OF THE CITIZENS OF

LOS ANGELES COUNTY AND OF

THE STATE OF CALIFORNIA.

SHEET NO

REV DATE BY APP REG NO. EXPIRES SEAL HOLDER DESCRIPTION

CORROSION CONTROL

DRAWING NO

CONTRACT NO

REV

601 S. FIGUEROA ST. SUITE 3800

LOS ANGELES, CA 90017

PS46172000

AS INDICATED

LOS ANGELES COUNTY

METROPOLITAN TRANSPORTATION AUTHORITY

23309 LA PALMA AVE YORBA LINDA, CA 92887

PASSENGER STATIONS III

IC

EPSNOITCETORPCI

OHTAC

ECA N

N A C E I N T E R N AT I O

HGNISJVRAS

No. 6125

D

TS

IL

A

TI

N AL

EXP. 05/07/25

CP-04

CP-04

HOLLYWOOD/WESTERN STATION

SCALE: NOT TO SCALE

SYMBOL CP EQUIPMENT REFERENCE DETAIL

EXISTING TEST

STATION -

TEST POINT -

PROPOSED TEST

STATION CP-16 / DETAIL 1

CP-04

VERMONT/SUNSET STATION

SCALE: NOT TO SCALE

HOLLYWOOD/WESTERN STATION

TEST STATION LOCATION ACTION

NEEDED REQUIREMENTS

1 STREET LEVEL NO N/A

2 STREET LEVEL YES INSTALL NEW ANODES (2)

3 STREET LEVEL YES INSTALL NEW ANODES (2)

4 STREET LEVEL NO N/A

5 STREET LEVEL YES LOCATE MISSING TEST STATION

6 STREET LEVEL NO N/A

7 STREET LEVEL NO N/A

8 STREET LEVEL NO N/A

9 STREET LEVEL NO N/A

10 STREET LEVEL NO N/A

11 STREET LEVEL YES REPLACE SHUNT (1)

12 STREET LEVEL YES REPLACE SHUNTS (2)

13 STREET LEVEL NO N/A

14 STREET LEVEL YES INSTALL NEW ANODES (2)

15 STREET LEVEL YES INSTALL NEW ANODES (2)

ELEVATOR #1 ROOM 211 NO N/A

ELEVATOR #2 ROOM 211 NO N/A

EAST FIRE PIT STREET LEVEL NO N/A

WEST FIRE PIT STREET LEVEL YES INSTALL ELECTRICAL ISOLATION (2)

VERMONT/SUNSET STATION

TEST STATION LOCATION ACTION

NEEDED REQUIREMENTS

1 STREET LEVEL NO N/A

2 STREET LEVEL YES INSTALL NEW ANODES (4)

3 STREET LEVEL YES LOCATE MISSING TEST STATION

4 STREET LEVEL YES INSTALL NEW ANODES (2)

5 STREET LEVEL YES INSTALL NEW ANODES (2)

6 STREET LEVEL YES INSTALL NEW ANODES (2)

7 STREET LEVEL YES INSTALL NEW ANODES (2)

8 STREET LEVEL NO N/A

IJ BOX (SD) NEAR ROOM 208 NO N/A

IJ BOX (?) NEAR ROOM 208 NO N/A

IJ BOX (2" DCW) NEAR ROOM 314 NO N/A

IJ BOX (16" SD) NEAR ROOM 314 NO N/A

ELEVATOR #1 ROOM 314 NO N/A

ELEVATOR #2 ROOM 314 NO N/A

ELEVATOR #3 ROOM 314 YES INSTALL NEW ANODES (2) AND REFERENCE ELECTRODE (1)

ELEVATOR #4 ROOM 314 YES INSTALL NEW ANODES (2) AND REFERENCE ELECTRODE (1)

EAST FIRE PIT STREET LEVEL NO N/A

WEST FIRE PIT STREET LEVEL NO N/A

L. PEDERSON

E. JOHNSON

L. PEDERSON/E. JOHNSON B-D LINES

IN CHARGE

CHECKED BY

SCALE

DRAWN BY

DESIGNED BY

S. SINGH

DATE:

THE PREPARATION OF THIS

DRAWING HAS BEEN FINANCED IN

PART THROUGH A GRANT FROM

THE U.S. DEPARTMENT OF

TRANSPORTATION, FEDERAL TRANSIT

ADMINISTRATION (FTA), UNDER THE

FEDERAL TRANSIT ACT OF 1964, AS

AMENDED, AND IN PART BY THE

TAXES OF THE CITIZENS OF

LOS ANGELES COUNTY AND OF

THE STATE OF CALIFORNIA.

SHEET NO

REV DATE BY APP REG NO. EXPIRES SEAL HOLDER DESCRIPTION

CORROSION CONTROL

DRAWING NO

CONTRACT NO

REV

601 S. FIGUEROA ST. SUITE 3800

LOS ANGELES, CA 90017

PS46172000

AS INDICATED

LOS ANGELES COUNTY

METROPOLITAN TRANSPORTATION AUTHORITY

23309 LA PALMA AVE YORBA LINDA, CA 92887

PASSENGER STATIONS IV

IC

EPSNOITCETORPCI

OHTAC

ECA N

N A C E I N T E R N AT I O

HGNISJVRAS

No. 6125

D

TS

IL

A

TI

N AL

EXP. 05/07/25

CP-05

CP-05

VERMONT/SANTA MONICA STATION

SCALE: NOT TO SCALE

SYMBOL CP EQUIPMENT REFERENCE DETAIL

EXISTING TEST

STATION -

TEST POINT -

PROPOSED TEST

STATION CP-16 / DETAIL 1

CP-05

VERMONT/BEVERLY STATION

SCALE: NOT TO SCALE

VERMONT/SANTA MONICA STATION

TEST STATION LOCATION ACTION

NEEDED REQUIREMENTS

1 STREET LEVEL YES INSTALL NEW ANODES (4)

2 STREET LEVEL YES INSTALL NEW ANODES (4)

3 STREET LEVEL NO N/A

4 STREET LEVEL NO N/A

5 STREET LEVEL YES INSTALL NEW ANODES (2)

6 STREET LEVEL YES INSTALL NEW ANODES (2)

7 STREET LEVEL YES INSTALL NEW ANODES (2)

8 STREET LEVEL YES INSTALL NEW ANODES (2)

9 STREET LEVEL NO N/A

10 STREET LEVEL NO N/A

11 STREET LEVEL NO N/A

12 STREET LEVEL NO N/A

13 STREET LEVEL NO N/A

14 STREET LEVEL YES REPLACE SHUNT (1)

IJ BOX (4" DW) N VALVE ROOM 41 NO N/A

IJ BOX (4" PD) EJECTOR RM 167 NO N/A

ELEVATOR #1 ROOM 32 YES REPAIR OR REPLACE WIRING

ELEVATOR #2 ROOM 32 YES INSTALL NEW ANODES (4)

ELEVATOR #3 ROOM 25 YES REPAIR OR REPLACE WIRING

ELEVATOR #4 ROOM 25 YES REPLACE REFERENCE ELECTRODE

NORTH FIRE PIT STREET LEVEL NO N/A

SOUTH FIRE PIT STREET LEVEL NO N/A

VERMONT/BEVERLY STATION

TEST STATION LOCATION ACTION

NEEDED REQUIREMENTS

1 STREET LEVEL YES INSTALL NEW ANODES (4)

2 STREET LEVEL YES INSTALL NEW ANODES (4)

3 STREET LEVEL YES INSTALL NEW ANODES (4)

4 STREET LEVEL YES INSTALL NEW ANODES (4)

5 STREET LEVEL YES INSTALL NEW ANODES (4)

6 STREET LEVEL YES INSTALL NEW ANODE (1)

7 STREET LEVEL NO N/A

8 STREET LEVEL NO N/A

9 STREET LEVEL YES LOCATE MISSING TEST STATION

10 STREET LEVEL NO N/A

IJ BOX (6" SPD) EJECTOR RM 53 NO N/A

IJ BOX (4" PW) FAN RM 87 NO N/A

ELEVATOR #1 ROOM 47 YES REPAIR OR REPLACE WIRING

ELEVATOR #2 ROOM 47 YES REPAIR OR REPLACE WIRING

NORTH FIRE PIT STREET LEVEL NO N/A

SOUTH FIRE PIT STREET LEVEL NO N/A

L. PEDERSON

E. JOHNSON

L. PEDERSON/E. JOHNSON B-D LINES

IN CHARGE

CHECKED BY

SCALE

DRAWN BY

DESIGNED BY

S. SINGH

DATE:

THE PREPARATION OF THIS

DRAWING HAS BEEN FINANCED IN

PART THROUGH A GRANT FROM

THE U.S. DEPARTMENT OF

TRANSPORTATION, FEDERAL TRANSIT

ADMINISTRATION (FTA), UNDER THE

FEDERAL TRANSIT ACT OF 1964, AS

AMENDED, AND IN PART BY THE

TAXES OF THE CITIZENS OF

LOS ANGELES COUNTY AND OF

THE STATE OF CALIFORNIA.

SHEET NO

REV DATE BY APP REG NO. EXPIRES SEAL HOLDER DESCRIPTION

CORROSION CONTROL

DRAWING NO

CONTRACT NO

REV

601 S. FIGUEROA ST. SUITE 3800

LOS ANGELES, CA 90017

PS46172000

AS INDICATED

LOS ANGELES COUNTY

METROPOLITAN TRANSPORTATION AUTHORITY

23309 LA PALMA AVE YORBA LINDA, CA 92887

PASSENGER STATIONS V

IC

EPSNOITCETORPCI

OHTAC

ECA N

N A C E I N T E R N AT I O

HGNISJVRAS

No. 6125

D

TS

IL

A

TI

N AL

EXP. 05/07/25

CP-06

CP-06

WILSHIRE/VERMONT STATION

SCALE: NOT TO SCALE

SYMBOL CP EQUIPMENT REFERENCE DETAIL

EXISTING TEST

STATION -

TEST POINT -

PROPOSED TEST

STATION CP-16 / DETAIL 1

CP-06

WILSHIRE/NORMANDIE STATION

SCALE: NOT TO SCALE

WILSHIRE/VERMONT STATION

TEST STATION LOCATION ACTION

NEEDED REQUIREMENTS

1 STREET LEVEL NO N/A

2 STREET LEVEL NO N/A

3 STREET LEVEL YES LOCATE MISSING WIRING

IJ BOX (WSP) W SPRINKLER

ROOM 356 NO N/A

IJ BOX (DCW) E SPRINKLER

ROOM 303 YES REPLACE ELECTRICAL ISOLATION

IJ BOX (WSP) E SPRINKLER

ROOM 303 NO

EAST FIRE PIT STREET LEVEL NO N/A

WEST FIRE PIT STREET LEVEL NO N/A

WILSHIRE/NORMANDIE STATION

TEST STATION LOCATION ACTION

NEEDED REQUIREMENTS

1 STREET LEVEL YES REPLACE SHUNT (1)

2 STREET LEVEL YES INSTALL NEW ANODES (2)

3 STREET LEVEL NO N/A

4 STREET LEVEL NO N/A

5 STREET LEVEL NO N/A

6 STREET LEVEL NO N/A

7 STREET LEVEL NO N/A

8 STREET LEVEL YES INSTALL NEW ANODES (2)

9 STREET LEVEL NO N/A

10 STREET LEVEL NO N/A

ELEVATOR #1 ROOM 67 YES INSTALL NEW ANODES (2)

ELEVATOR #2 ROOM 67 YES INSTALL NEW ANODES 24)

NORTH FIRE PIT STREET LEVEL NO N/A

SOUTH FIRE PIT STREET LEVEL NO N/A

L. PEDERSON

E. JOHNSON

L. PEDERSON/E. JOHNSON B-D LINES

IN CHARGE

CHECKED BY

SCALE

DRAWN BY

DESIGNED BY

S. SINGH

DATE:

THE PREPARATION OF THIS

DRAWING HAS BEEN FINANCED IN

PART THROUGH A GRANT FROM

THE U.S. DEPARTMENT OF

TRANSPORTATION, FEDERAL TRANSIT

ADMINISTRATION (FTA), UNDER THE

FEDERAL TRANSIT ACT OF 1964, AS

AMENDED, AND IN PART BY THE

TAXES OF THE CITIZENS OF

LOS ANGELES COUNTY AND OF

THE STATE OF CALIFORNIA.

SHEET NO

REV DATE BY APP REG NO. EXPIRES SEAL HOLDER DESCRIPTION

CORROSION CONTROL

DRAWING NO

CONTRACT NO

REV

601 S. FIGUEROA ST. SUITE 3800

LOS ANGELES, CA 90017

PS46172000

AS INDICATED

LOS ANGELES COUNTY

METROPOLITAN TRANSPORTATION AUTHORITY

23309 LA PALMA AVE YORBA LINDA, CA 92887

PASSENGER STATIONS VI

IC

EPSNOITCETORPCI

OHTAC

ECA N

N A C E I N T E R N AT I O

HGNISJVRAS

No. 6125

D

TS

IL

A

TI

N AL

EXP. 05/07/25

CP-07

CP-07

WILSHIRE/WESTERN STATION

SCALE: NOT TO SCALE

SYMBOL CP EQUIPMENT REFERENCE DETAIL

EXISTING TEST

STATION -

TEST POINT -

PROPOSED TEST

STATION CP-16 / DETAIL 1

CP-07

WESTLAKE/MACARTHUR PARK STATION

SCALE: NOT TO SCALE

WILSHIRE/WESTERN STATION

TEST STATION LOCATION ACTION

NEEDED REQUIREMENTS

1 STREET LEVEL NO N/A

2 STREET LEVEL YES INSTALL NEW ANODES (2)

3 STREET LEVEL YES INSTALL NEW ANODES (4)

4 STREET LEVEL YES INSTALL NEW ANODES (4)

5 STREET LEVEL YES INSTALL NEW ANODES (2)

6 STREET LEVEL YES INSTALL NEW ANODES (2)

7 STREET LEVEL YES INSTALL NEW ANODES (2)

8 STREET LEVEL YES REPLACE SHUNT (1)

9 STREET LEVEL NO N/A

10 STREET LEVEL YES INSTALL NEW ANODES (2)

11 STREET LEVEL YES REPLACE SHUNT (1)

12 STREET LEVEL YES REPLACE SHUNT (1)

13 STREET LEVEL YES INSTALL NEW ANODES (6)

14 STREET LEVEL YES INSTALL NEW ANODES (4)

15 STREET LEVEL NO N/A

16 STREET LEVEL YES REPLACE SHUNT (1)

IJ BOX (8" WSP) ROOM 24 NO N/A

IJ BOX (CWL) ROOM 24 NO N/A

IJ BOX (8" WSP) ROOM 39 NO N/A

ELEVATOR #1 ROOM 59 NO N/A

ELEVATOR #2 ROOM 59 YES INSTALL NEW ANODES (4)

NORTH FIRE PIT STREET LEVEL YES INSTALL ELECTRICAL ISOLATION (1)

SOUTH FIRE PIT STREET LEVEL YES INSTALL ELECTRICAL ISOLATION (2)

WESTLAKE/MACARTHUR PARK STATION

TEST STATION LOCATION ACTION

NEEDED REQUIREMENTS

1 STREET LEVEL YES INSTALL NEW ANODES (4)

2 STREET LEVEL YES INSTALL NEW ANODES (4)

3 STREET LEVEL YES INSTALL NEW ANODES (2)

4 STREET LEVEL NO N/A

5 STREET LEVEL YES INSTALL NEW ANODES (2)

6 STREET LEVEL YES REPLACE SHUNT (1)

7 STREET LEVEL YES INSTALL NEW ANODES (4)

8 STREET LEVEL YES INSTALL NEW ANODES (4)

9 STREET LEVEL YES INSTALL NEW ANODES (4)

ELEVATOR #501 ROOM 4 YES REPAIR WIRING, INSTALL REFERENCE ELECTRODE

ELEVATOR #502 ROOM 4 YES INSTALL NEW ANODES (2), INSTALL TEST STATION

SPARK A STATION YES INSTALL ELECTRICAL ISOLATION (1)

DCW STATION NO N/A

EAST LINE (WSP) STATION NO N/A

WEST LINE (WSP) STATION YES INSTALL ELECTRICAL ISOLATION (1)

EAST FIRE PIT STREET LEVEL YES INSTALL ELECTRICAL ISOLATION (1)

WEST FIRE PIT STREEL LEVEL YES INSTALL ELECTRICAL ISOLATION (1)

L. PEDERSON

E. JOHNSON

L. PEDERSON/E. JOHNSON B-D LINES

IN CHARGE

CHECKED BY

SCALE

DRAWN BY

DESIGNED BY

S. SINGH

DATE:

THE PREPARATION OF THIS

DRAWING HAS BEEN FINANCED IN

PART THROUGH A GRANT FROM

THE U.S. DEPARTMENT OF

TRANSPORTATION, FEDERAL TRANSIT

ADMINISTRATION (FTA), UNDER THE

FEDERAL TRANSIT ACT OF 1964, AS

AMENDED, AND IN PART BY THE

TAXES OF THE CITIZENS OF

LOS ANGELES COUNTY AND OF

THE STATE OF CALIFORNIA.

SHEET NO

REV DATE BY APP REG NO. EXPIRES SEAL HOLDER DESCRIPTION

CORROSION CONTROL

DRAWING NO

CONTRACT NO

REV

601 S. FIGUEROA ST. SUITE 3800

LOS ANGELES, CA 90017

PS46172000

AS INDICATED

LOS ANGELES COUNTY

METROPOLITAN TRANSPORTATION AUTHORITY

23309 LA PALMA AVE YORBA LINDA, CA 92887

PASSENGER STATIONS VII

IC

EPSNOITCETORPCI

OHTAC

ECA N

N A C E I N T E R N AT I O

HGNISJVRAS

No. 6125

D

TS

IL

A

TI

N AL

EXP. 05/07/25

CP-08

CP-08

7TH ST/METRO CENTER STATION

SCALE: NOT TO SCALE

SYMBOL CP EQUIPMENT REFERENCE DETAIL

EXISTING TEST

STATION -

TEST POINT -

PROPOSED TEST

STATION CP-16 / DETAIL 1

CP-08

PERSHING SQUARE STATION

SCALE: NOT TO SCALE

7TH STREET/METRO CENTER STATION

TEST STATION LOCATION ACTION

NEEDED REQUIREMENTS

1 STREET LEVEL YES INSTALL NEW ANODES (2)

2 STREET LEVEL YES INSTALL NEW ANODES (2)

3 STREET LEVEL YES INSTALL NEW ANODES (2)

4 STREET LEVEL YES INSTALL NEW ANODES (2)

5 STREET LEVEL YES INSTALL NEW ANODES (2)

6 STREET LEVEL YES INSTALL NEW ANODES (2)

7 STREET LEVEL YES INSTALL NEW ANODES (4)

8 STREET LEVEL YES INSTALL NEW ANODES (2)

ELEVATOR #401 ROOM 32 YES INSTALL REFERNCE ELECTRODE

ELEVATOR #402 ROOM 52 YES INSTALL REFERNCE ELECTRODE

ELEVATOR #404 ROOM 84 YES INSTALL REFERNCE ELECTRODE

ELEVATOR #405 ROOM 84 YES INSTALL REFERNCE ELECTRODE

ELEVATOR 51459 ROOM 81 YES INSTALL REFERNCE ELECTRODE

EAST FIRE PIT STREET LEVEL YES INSTALL ELECTRICAL ISOLATION (1)

WEST FIRE PIT STREEL LEVEL YES INSTALL ELECTRICAL ISOLATION (4)

NORTH FIRE PIT STREET LEVEL YES INSTALL ELECTRICAL ISOLATION (1)

SOUTH FIRE PIT STREET LEVEL YES INSTALL ELECTRICAL ISOLATION (1)

PERSHING SQUARE STATION

TEST STATION LOCATION ACTION

NEEDED REQUIREMENTS

1 STREET LEVEL YES INSTALL NEW ANODES (2)

2 STREET LEVEL YES INSTALL NEW ANODES (2)

3 STREET LEVEL YES INSTALL NEW ANODES (2)

4 STREET LEVEL NO N/A

5 STREET LEVEL YES INSTALL NEW ANODES (2)

6 STREET LEVEL YES INSTALL NEW ANODES (2)

7 STREET LEVEL NO N/A

IJ BOX (4" SPR) VALVE ROOM 11 NO N/A

IJ BOX (8" WSP) VALVE ROOM 11 NO N/A

IJ BOX (8" WSP) VALVE ROOM 80 YES INSTALL ELECTRICAL ISOLATION (1)

IJ BOX (8" WSP) VALVE ROOM 80 NO N/A

IJ BOX (4" SPR) VALVE ROOM 36 YES INSTALL ELECTRICAL ISOLATION (1)

IJ BOX (8" WSP) VALVE ROOM 36 YES INSTALL ELECTRICAL ISOLATION (1)

ELEVATOR #301 ROOM 301 YES INSTALL REFERNCE ELECTRODE

ELEVATOR #302 ROOM 302 YES INSTALL REFERNCE ELECTRODE

NORTH FIRE PIT STREET LEVEL NO N/A

SOUTH FIRE PIT STREET LEVEL YES INSTALL ELECTRICAL ISOLATION (1)

L. PEDERSON

E. JOHNSON

L. PEDERSON/E. JOHNSON B-D LINES

IN CHARGE

CHECKED BY

SCALE

DRAWN BY

DESIGNED BY

S. SINGH

DATE:

THE PREPARATION OF THIS

DRAWING HAS BEEN FINANCED IN

PART THROUGH A GRANT FROM

THE U.S. DEPARTMENT OF

TRANSPORTATION, FEDERAL TRANSIT

ADMINISTRATION (FTA), UNDER THE

FEDERAL TRANSIT ACT OF 1964, AS

AMENDED, AND IN PART BY THE

TAXES OF THE CITIZENS OF

LOS ANGELES COUNTY AND OF

THE STATE OF CALIFORNIA.

SHEET NO

REV DATE BY APP REG NO. EXPIRES SEAL HOLDER DESCRIPTION

CORROSION CONTROL

DRAWING NO

CONTRACT NO

REV

601 S. FIGUEROA ST. SUITE 3800

LOS ANGELES, CA 90017

PS46172000

AS INDICATED

LOS ANGELES COUNTY

METROPOLITAN TRANSPORTATION AUTHORITY

23309 LA PALMA AVE YORBA LINDA, CA 92887

PASSENGER STATIONS VIII

IC

EPSNOITCETORPCI

OHTAC

ECA N

N A C E I N T E R N AT I O

HGNISJVRAS

No. 6125

D

TS

IL

A

TI

N AL

EXP. 05/07/25

CP-09

CP-09

CIVIC CENTER STATION

SCALE: NOT TO SCALE

SYMBOL CP EQUIPMENT REFERENCE DETAIL

EXISTING TEST

STATION -

TEST POINT -

PROPOSED TEST

STATION CP-16 / DETAIL 1

CP-09

UNION SQUARE STATION

SCALE: NOT TO SCALE

CIVIC CENTER STATION

TEST STATION LOCATION ACTION

NEEDED REQUIREMENTS

1 STREET LEVEL YES INSTALL NEW ANODES (2)

2 STREET LEVEL YES INSTALL NEW ANODES (2)

3 STREET LEVEL YES INSTALL NEW ANODES (4)

4 STREET LEVEL YES INSTALL NEW ANODES (4)

5 STREET LEVEL YES INSTALL NEW ANODES (4)

6 STREET LEVEL YES INSTALL NEW ANODES (4)

7 STREET LEVEL YES INSTALL NEW ANODES (4)

ELEVATOR #201 ELEVATOR ROOM YES INSTALL REFERENCE ELECTRODE

ELEVATOR #202 ELEVATOR ROOM YES LOCATE TEST STATION

NORTH FIRE PIT STREET LEVEL NO N/A

SOUTH FIRE PIT STREET LEVEL NO N/A

UNION SQUARE STATION

TEST STATION LOCATION ACTION

NEEDED REQUIREMENTS

1 STREET LEVEL YES INSTALL NEW TEST STATION

2 STREET LEVEL YES INSTALL NEW TEST STATION

3 STREET LEVEL YES INSTALL NEW ANODES (4)

4 STREET LEVEL NO N/A

5 STREET LEVEL YES LOCATE MISSING TEST STATION

6 STREET LEVEL YES LOCATE MISSING TEST STATION

IJ BOX (6" PD) UTILITY RM GP-56M YES IDENTIFY WIRING

ELEVATOR #102 M-15 RM 101 & 102 YES INSTALL REFERENCE ELECTRODE

ELEVATOR #103 M-25 RM 103 & 104 YES INSTALL REFERENCE ELECTRODE

ELEVATOR #104 M-25 RM 103 & 105 YES INSTALL REFERENCE ELECTRODE

EAST FIRE PIT STREET LEVEL YES INSTALL ELECTRICAL ISOLATION (3)

WEST FIRE PIT STREET LEVEL YES INSTALL ELECTRICAL ISOLATION (4)

L. PEDERSON

E. JOHNSON

L. PEDERSON/E. JOHNSON B-D LINES

IN CHARGE

CHECKED BY

SCALE

DRAWN BY

DESIGNED BY

S. SINGH

DATE:

THE PREPARATION OF THIS

DRAWING HAS BEEN FINANCED IN

PART THROUGH A GRANT FROM

THE U.S. DEPARTMENT OF

TRANSPORTATION, FEDERAL TRANSIT

ADMINISTRATION (FTA), UNDER THE

FEDERAL TRANSIT ACT OF 1964, AS

AMENDED, AND IN PART BY THE

TAXES OF THE CITIZENS OF

LOS ANGELES COUNTY AND OF

THE STATE OF CALIFORNIA.

SHEET NO

REV DATE BY APP REG NO. EXPIRES SEAL HOLDER DESCRIPTION

CORROSION CONTROL

DRAWING NO

CONTRACT NO

REV

601 S. FIGUEROA ST. SUITE 3800

LOS ANGELES, CA 90017

PS46172000

AS INDICATED

LOS ANGELES COUNTY

METROPOLITAN TRANSPORTATION AUTHORITY

23309 LA PALMA AVE YORBA LINDA, CA 92887

DIVISION 20 YARD LAYOUT

IC

EPSNOITCETORPCI

OHTAC

ECA N

N A C E I N T E R N AT I O

HGNISJVRAS

No. 6125

D

TS

IL

A

TI

N AL

EXP. 05/07/25

CP-10

CP-10

SITE LAYOUT - DIVISION 20 YARD

SCALE: NOT TO SCALE

SYMBOL CP EQUIPMENT REFERENCE DETAIL

EXISTING TEST

STATION -

TEST POINT -

PROPOSED TEST

STATION CP-09 / DETAIL 1

CP-10

DIVISION 20 YARD - AREA 1

SCALE: NOT TO SCALE

TS 3

TS 2

AREA 1

SEE DETAIL 2

TS 7

AREA 2

SEE DETAIL 3

AREA 3

SEE DETAIL 4

CP-10

DIVISION 20 YARD - AREA 2

SCALE: NOT TO SCALE

CP-10

DIVISION 20 YARD - AREA 3

SCALE: NOT TO SCALE

TEST

STATION ACTION NEEDED REQUIREMENTS

1 CNL N/A

2 YES INSTALL NEW ANODES

3 YES INSTALL NEW ANODES

4 YES INSTALL NEW ANODES

5 CNL DEMOLISHED DUE TO CONSTRUCTION

6 YES INSTALL NEW ANODES

7 YES INSTALL NEW ANODES

NORTH

FIRE PIT NO N/A

SOUTH

FIRE PIT NO N/A

TS 4

CONSTRUCTION

AREA, TS 5 MISSING

TS 6

S FP

N FP

L. PEDERSON

E. JOHNSON

L. PEDERSON/E. JOHNSON B-D LINES

IN CHARGE

CHECKED BY

SCALE

DRAWN BY

DESIGNED BY

S. SINGH

DATE:

THE PREPARATION OF THIS

DRAWING HAS BEEN FINANCED IN

PART THROUGH A GRANT FROM

THE U.S. DEPARTMENT OF

TRANSPORTATION, FEDERAL TRANSIT

ADMINISTRATION (FTA), UNDER THE

FEDERAL TRANSIT ACT OF 1964, AS

AMENDED, AND IN PART BY THE

TAXES OF THE CITIZENS OF

LOS ANGELES COUNTY AND OF

THE STATE OF CALIFORNIA.

SHEET NO

REV DATE BY APP REG NO. EXPIRES SEAL HOLDER DESCRIPTION

CORROSION CONTROL

DRAWING NO

CONTRACT NO

REV

601 S. FIGUEROA ST. SUITE 3800

LOS ANGELES, CA 90017

PS46172000

AS INDICATED

LOS ANGELES COUNTY

METROPOLITAN TRANSPORTATION AUTHORITY

23309 LA PALMA AVE YORBA LINDA, CA 92887

FIRE PIT DETAILS I

IC

EPSNOITCETORPCI

OHTAC

ECA N

N A C E I N T E R N AT I O

HGNISJVRAS

No. 6125

D

TS

IL

A

TI

N AL

EXP. 05/07/25

CP-11

NORTH HOLLYWOOD - NORTH FIRE PIT

SCALE: NOT TO SCALE

CP-11

CP-11

NORTH HOLLYWOOD - NORTH FIRE PIT

SCALE: NOT TO SCALE

CP-11

NORTH HOLLYWOOD - SOUTH FIRE PIT

SCALE: NOT TO SCALE

CP-11

UNIVERSAL CITY - NORTH FIRE PIT

SCALE: NOT TO SCALE

CP-11

HOLLYWOOD/WESTERN - WEST FIRE PIT

SCALE: NOT TO SCALE 6

CP-11

HOLLYWOOD/WESTERN - WEST FIRE PIT

SCALE: NOT TO SCALE

L. PEDERSON

E. JOHNSON

L. PEDERSON/E. JOHNSON B-D LINES

IN CHARGE

CHECKED BY

SCALE

DRAWN BY

DESIGNED BY

S. SINGH

DATE:

THE PREPARATION OF THIS

DRAWING HAS BEEN FINANCED IN

PART THROUGH A GRANT FROM

THE U.S. DEPARTMENT OF

TRANSPORTATION, FEDERAL TRANSIT

ADMINISTRATION (FTA), UNDER THE

FEDERAL TRANSIT ACT OF 1964, AS

AMENDED, AND IN PART BY THE

TAXES OF THE CITIZENS OF

LOS ANGELES COUNTY AND OF

THE STATE OF CALIFORNIA.

SHEET NO

REV DATE BY APP REG NO. EXPIRES SEAL HOLDER DESCRIPTION

CORROSION CONTROL

DRAWING NO

CONTRACT NO

REV

601 S. FIGUEROA ST. SUITE 3800

LOS ANGELES, CA 90017

PS46172000

AS INDICATED

LOS ANGELES COUNTY

METROPOLITAN TRANSPORTATION AUTHORITY

23309 LA PALMA AVE YORBA LINDA, CA 92887

FIRE PIT DETAILS II

IC

EPSNOITCETORPCI

OHTAC

ECA N

N A C E I N T E R N AT I O

HGNISJVRAS

No. 6125

D

TS

IL

A

TI

N AL

EXP. 05/07/25

CP-12

WILSHIRE/WESTERN - NORTH FIRE PIT

SCALE: NOT TO SCALE

CP-12

CP-12

WILSHIRE/WESTERN - SOUTH FIRE PIT

SCALE: NOT TO SCALE

CP-12

WESTLAKE/MACARTHUR PARK - EAST FIRE PIT

SCALE: NOT TO SCALE

CP-12

WESTLAKE/MACARTHUR PARK - WEST FIRE PIT

L. PEDERSON

E. JOHNSON

L. PEDERSON/E. JOHNSON B-D LINES

IN CHARGE

CHECKED BY

SCALE

DRAWN BY

DESIGNED BY

S. SINGH

DATE:

THE PREPARATION OF THIS

DRAWING HAS BEEN FINANCED IN

PART THROUGH A GRANT FROM

THE U.S. DEPARTMENT OF

TRANSPORTATION, FEDERAL TRANSIT

ADMINISTRATION (FTA), UNDER THE

FEDERAL TRANSIT ACT OF 1964, AS

AMENDED, AND IN PART BY THE

TAXES OF THE CITIZENS OF

LOS ANGELES COUNTY AND OF

THE STATE OF CALIFORNIA.

SHEET NO

REV DATE BY APP REG NO. EXPIRES SEAL HOLDER DESCRIPTION

CORROSION CONTROL

DRAWING NO

CONTRACT NO

REV

601 S. FIGUEROA ST. SUITE 3800

LOS ANGELES, CA 90017

PS46172000

AS INDICATED

LOS ANGELES COUNTY

METROPOLITAN TRANSPORTATION AUTHORITY

23309 LA PALMA AVE YORBA LINDA, CA 92887

FIRE PIT DETAILS III

IC

EPSNOITCETORPCI

OHTAC

ECA N

N A C E I N T E R N AT I O

HGNISJVRAS

No. 6125

D

TS

IL

A

TI

N AL

EXP. 05/07/25

CP-13

7TH STREET/METRO CTR - WEST FIRE PIT

SCALE: NOT TO SCALE

CP-13

CP-13

7TH STREET/METRO CTR - EAST FIRE PIT

SCALE: NOT TO SCALE

CP-13

7TH STREET/METRO CTR - SOUTH FIRE PIT

SCALE: NOT TO SCALE

CP-13

7TH STREET/METRO CTR - NORTH FIRE PIT

SCALE: NOT TO SCALE

CP-13

7TH STREET/METRO CTR - WEST FIRE PIT

SCALE: NOT TO SCALE

CP-13

7TH STREET/METRO CTR - WEST FIRE PIT

L. PEDERSON

E. JOHNSON

L. PEDERSON/E. JOHNSON B-D LINES

IN CHARGE

CHECKED BY

SCALE

DRAWN BY

DESIGNED BY

S. SINGH

DATE:

THE PREPARATION OF THIS

DRAWING HAS BEEN FINANCED IN

PART THROUGH A GRANT FROM

THE U.S. DEPARTMENT OF

TRANSPORTATION, FEDERAL TRANSIT

ADMINISTRATION (FTA), UNDER THE

FEDERAL TRANSIT ACT OF 1964, AS

AMENDED, AND IN PART BY THE

TAXES OF THE CITIZENS OF

LOS ANGELES COUNTY AND OF

THE STATE OF CALIFORNIA.

SHEET NO

REV DATE BY APP REG NO. EXPIRES SEAL HOLDER DESCRIPTION

CORROSION CONTROL

DRAWING NO

CONTRACT NO

REV

601 S. FIGUEROA ST. SUITE 3800

LOS ANGELES, CA 90017

PS46172000

AS INDICATED

LOS ANGELES COUNTY

METROPOLITAN TRANSPORTATION AUTHORITY

23309 LA PALMA AVE YORBA LINDA, CA 92887

FIRE PIT DETAILS IV

IC

EPSNOITCETORPCI

OHTAC

ECA N

N A C E I N T E R N AT I O

HGNISJVRAS

No. 6125

D

TS

IL

A

TI

N AL

EXP. 05/07/25

CP-14

PERSHING SQ - SOUTH FIRE PIT

SCALE: NOT TO SCALE

CP-14

CP-14

PERSHING SQ - SOUTH FIRE PIT

SCALE: NOT TO SCALE

CP-14

UNION STATION - EAST FIRE PIT

SCALE: NOT TO SCALE

CP-14

UNION STATION - EAST FIRE PIT

SCALE: NOT TO SCALE

CP-14

UNION STATION - WEST FIRE PIT

SCALE: NOT TO SCALE

CP-14

UNION STATION - WEST FIRE PIT

SCALE: NOT TO SCALE

CP-14

UNION STATION - WEST FIRE PIT

CP-15

INSULATING KIT/DIELECTRIC UNION SCHEDULE

SCALE: NOT TO SCALE

10/30/24

L. PEDERSON

E. JOHNSON

L. PEDERSON/E. JOHNSON B-D LINES

IN CHARGE

CHECKED BY

SCALE

DRAWN BY

DESIGNED BY

S. SINGH

DATE:

THE PREPARATION OF THIS

DRAWING HAS BEEN FINANCED IN

PART THROUGH A GRANT FROM

THE U.S. DEPARTMENT OF

TRANSPORTATION, FEDERAL TRANSIT

ADMINISTRATION (FTA), UNDER THE

FEDERAL TRANSIT ACT OF 1964, AS

AMENDED, AND IN PART BY THE

TAXES OF THE CITIZENS OF

LOS ANGELES COUNTY AND OF

THE STATE OF CALIFORNIA.

SHEET NO

REV DATE BY APP REG NO. EXPIRES SEAL HOLDER DESCRIPTION

CORROSION CONTROL

DRAWING NO

CONTRACT NO

REV

601 S. FIGUEROA ST. SUITE 3800

LOS ANGELES, CA 90017

PS46172000

AS INDICATED

LOS ANGELES COUNTY

METROPOLITAN TRANSPORTATION AUTHORITY

23309 LA PALMA AVE YORBA LINDA, CA 92887

STATION PIPE INSULATING DETAILS

IC

EPSNOITCETORPCI

OHTAC

ECA N

N A C E I N T E R N AT I O

HGNISJVRAS

No. 6125

D

TS

IL

A

TI

N AL

EXP. 05/07/25

CP-15

INSULATING FLANGE KIT INSTALLATION/REPLACEMENT SCHEDULE

PASSENGER STATION UTILITY DIA LOCATION

NORTH HOLLYWOOD FIRE WATER N/A NORTH FIRE PIT

NORTH HOLLYWOOD FIRE WATER N/A NORTH FIRE PIT

NORTH HOLLYWOOD FIRE WATER N/A SOUTH FIRE PIT

UNIVERSAL CITY FIRE WATER N/A NORTH FIRE PIT

UNIVERSAL CITY N/A N/A N/A

HOLLYWOOD/WESTERN DIELECTRIC UNION N/A WEST FIRE PIT

HOLLYWOOD/WESTERN DIELECTRIC UNION N/A WEST FIRE PIT

WILSHIRE/VERMONT DCW N/A ROOM 356

WILSHIRE/WESTERN FIRE WATER N/A NORTH FIRE PIT

WILSHIRE/WESTERN FIRE WATER N/A SOUTH FIRE PIT

WILSHIRE/WESTERN FIRE WATER N/A SOUTH FIRE PIT

WESTLAKE FIRE WATER N/A EAST FIRE PIT

WESTLAKE FIRE WATER N/A WEST FIRE PIT

WESTLAKE SPARK A N/A N/A

WESTLAKE WEST LINE N/A N/A

7TH ST/METRO FIRE WATER N/A EAST FIRE PIT

7TH ST/METRO FIRE WATER N/A WEST FIRE PIT

7TH ST/METRO FIRE WATER N/A WEST FIRE PIT

7TH ST/METRO FIRE WATER N/A WEST FIRE PIT

7TH ST/METRO FIRE WATER N/A WEST FIRE PIT

7TH ST/METRO FIRE WATER N/A NORTH FIRE PIT

7TH ST/METRO FIRE WATER N/A SOUTH FIRE PIT

PERSHING SQUARE FIRE WATER N/A SOUTH FIRE PIT

PERSHING SQUARE WSP 8" ROOM 80

PERSHING SQUARE SPR 4" ROOM 36

PERSHING SQUARE WSP 8" ROOM 36

UNION STATION FIRE WATER N/A EAST FIRE PIT

UNION STATION FIRE WATER N/A EAST FIRE PIT

UNION STATION FIRE WATER N/A EAST FIRE PIT

UNION STATION FIRE WATER N/A WEST FIRE PIT

UNION STATION FIRE WATER N/A WEST FIRE PIT

UNION STATION FIRE WATER N/A WEST FIRE PIT

UNION STATION FIRE WATER N/A WEST FIRE PIT

CP-16

GACP TEST STATION DETAIL

SCALE: NOT TO SCALE

ANODE CABLE

TO NEW OR EXISTING TEST

STATION, SEE DETAIL

NATURAL SOIL BACKFILL

BACKFILL COMPOSITION

75% GYPSUM

20% BENTONITE

5% SODIUM SULPHATE

48LB. ANODE SPECS:

INGOT WEIGHT: 48 LBS.

PKGD WEIGHT: 96 LBS.

INGOT DIMENSIONS: 5" X 5" X 31"

PKGD DIMENSIONS: 8" X 34"

ELEMENT CONTENT %

Al 0.010%

Mn 0.50 - 1.30%

Cu 0.02% MAX.

Ni 0.001% MAX.

OTHER 0.30% MAX.

Mg REMAINDER

Fe 0.03% MAX.

CHEMICAL COMPOSITION

IMPORTANT NOTE:

REMOVE PLASTIC BAG

FROM ANODE BEFORE

INSTALLING.

REFERENCE

ELECTRODE, SEE

DETAIL 1

CP-17

#12 AWG THHN STRUCTURE LEADS

PIN-BRAZED TO PIPE

FLUSH TEST STATION WITH TERMINAL

BOARD, SEE DETAIL 3

GRADE

0.01 OHM WIRE SHUNT

TERMINAL FOR

ANODE CABLE(S)

TERMINAL FOR

STRUCTURE TEST

TERMINAL FOR

STRUCURE CABLE

TERMINAL FOR

REFERENCE

ELECTRODE

6'

GRADE

PACKAGED BACKFILL

MAGNESIUM ALLOY INGOT

GALVANIZED STEEL CORE

CLOTH BAG

EPOXY

SILVER SOLDERED

CONNECTION

SECURE WITH

TIE WIRE

#12 AWG XHHW

LEAD WIRE

PACKAGED HIGH POTENTIAL

48# MAGNESIUM ANODE, SEE DETAIL

(QUANTITIES AS SHOWN ON LAYOUT SHEETS)

HIGH-POTENTIAL MAGNESIUM

ANODE INSTALLATION, SEE DETAIL

12"

5' MIN

CP-16

ANODE INSTALLATION DETAIL

SCALE: NOT TO SCALE

CP-16

HIGH POTENTIAL MAGNESIUM ANODE DETAIL

SCALE: NOT TO SCALE

CP-16

TEST STATION PANEL BOARD DETAIL

SCALE: NOT TO SCALE

TEST REF

PIPE ANODE

5" X 4" PHENOLIC PANEL BOARD

ENGRAVING

10/30/24

L. PEDERSON

E. JOHNSON

L. PEDERSON/E. JOHNSON B-D LINES

IN CHARGE

CHECKED BY

SCALE

DRAWN BY

DESIGNED BY

S. SINGH

DATE:

THE PREPARATION OF THIS

DRAWING HAS BEEN FINANCED IN

PART THROUGH A GRANT FROM

THE U.S. DEPARTMENT OF

TRANSPORTATION, FEDERAL TRANSIT

ADMINISTRATION (FTA), UNDER THE

FEDERAL TRANSIT ACT OF 1964, AS

AMENDED, AND IN PART BY THE

TAXES OF THE CITIZENS OF

LOS ANGELES COUNTY AND OF

THE STATE OF CALIFORNIA.

SHEET NO

REV DATE BY APP REG NO. EXPIRES SEAL HOLDER DESCRIPTION

CORROSION CONTROL

DRAWING NO

CONTRACT NO

REV

601 S. FIGUEROA ST. SUITE 3800

LOS ANGELES, CA 90017

PS46172000

AS INDICATED

LOS ANGELES COUNTY

METROPOLITAN TRANSPORTATION AUTHORITY

23309 LA PALMA AVE YORBA LINDA, CA 92887

CATHODIC PROTECTION DETAILS I

IC

EPSNOITCETORPCI

OHTAC

ECA N

N A C E I N T E R N AT I O

HGNISJVRAS

No. 6125

D

TS

IL

A

TI

N AL

EXP. 05/07/25

CP-16

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PIPELINE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

CP-17

REFERENCE ELECTRODE DETAIL

SCALE: NOT TO SCALE

#12 AWG XHHW LOOPED

SNUGLY AROUND PIPE

ROUTE CABLE TO

TEST STATION

CP-17

STRUCTURE CONNECTION TO PIPE

SCALE: NOT TO SCALE

PIN BRAZED

CONNECTION, SEE

DETAIL 4

BELOW GRADE CONNECTION

ABOVE GRADE

CONNECTION

#12 AWG XHHW CABLE

ROUTED BACK TO TEST

STATION

CP-17

ELECTRICAL ISOLATION DETAILS

SCALE: NOT TO SCALE

ABOVE GRADE PIPING

METALLIC

UNION BODY

ISOLATING FITTING

BELOW GRADE PIPING

INSULATING WASHER (TYP)

INSULATING GASKET

STEEL FLANGE BOLTINSULATING SLEEVE

PROTECTED PIPE

FLANGE

STEEL WASHER (TYP)

STEEL FLANGE NUT

UNPROTECTED PIPE

CP-17

PIN BRAZING DETAILS

SCALE: NOT TO SCALE

PROCEDURE:

STEP 1 REMOVE COATING FOR 2" FROM PIN LOCATION. FILE PIPE TO BRIGHT METAL

FINISH AND DRY ANY MOISTURE WITH A TOWEL.

STEP 2 INSERT PIN AND CERAMIC FERRULE INTO GUN.

STEP 3 POSITION GUN AS REQUIRED ON METAL SURFACE.

STEP 4 DEPRESS TRIGGER TO BRAZE PIN TO METAL.

STEP 5 TEST THE CONNECTION WITH A HAMMER. THIS WILL ALSO REMOVE CERAMIC

FERRULE. DO NOT DAMAGE THREADS ON PIN.

NOTES:

1. FOR BURIED PIPE-TO-CABLE CONNECTIONS, THE DIRECT PIN BRAZE CONNECTION (NOT

THE THREADED STUD) SHALL BE USED ALONG WITH A ROYSTON HANDY CAP) OR EQUAL.

2. COAT ALL BURIED PIN BRAZED WITH APPROVED MASTIC COATING.

COATING REPAIR AS SPECIFIED,

SEE NOTE

CABLE LUG

CABLE

M8 THREADED BRAZING

PIN WITH NUTS AND

WASHER

CERAMIC FERRULE FOR

THREADED PIN

PIPE COATING

EXPOSED METAL SURFACE2"

#14 AWG STRANDED COPPER

CABLE WITH RHW INSULATION

10/30/24

L. PEDERSON

E. JOHNSON

L. PEDERSON/E. JOHNSON B-D LINES

IN CHARGE

CHECKED BY

SCALE

DRAWN BY

DESIGNED BY

S. SINGH

DATE:

THE PREPARATION OF THIS

DRAWING HAS BEEN FINANCED IN

PART THROUGH A GRANT FROM

THE U.S. DEPARTMENT OF

TRANSPORTATION, FEDERAL TRANSIT

ADMINISTRATION (FTA), UNDER THE

FEDERAL TRANSIT ACT OF 1964, AS

AMENDED, AND IN PART BY THE

TAXES OF THE CITIZENS OF

LOS ANGELES COUNTY AND OF

THE STATE OF CALIFORNIA.

SHEET NO

REV DATE BY APP REG NO. EXPIRES SEAL HOLDER DESCRIPTION

CORROSION CONTROL

DRAWING NO

CONTRACT NO

REV

601 S. FIGUEROA ST. SUITE 3800

LOS ANGELES, CA 90017

PS46172000

AS INDICATED

LOS ANGELES COUNTY

METROPOLITAN TRANSPORTATION AUTHORITY

23309 LA PALMA AVE YORBA LINDA, CA 92887

CATHODIC PROTECTION DETAILS II

IC

EPSNOITCETORPCI

OHTAC

ECA N

N A C E I N T E R N AT I O

HGNISJVRAS

No. 6125

D

TS

IL

A

TI

N AL

EXP. 05/07/25

CP-17

AutoCAD SHX Text

TOP OF PIPE

AutoCAD SHX Text

GRADE

AutoCAD SHX Text

PIPE

FLOW

CP-18

TYPICAL ELEVATOR CP JUNCTION BOX

SCALE: NOT TO SCALE

CP-18

TYPICAL ELEVATOR CP INSTALLATION

SCALE: NOT TO SCALE

WATERPROOF COLLAR

STEEL CASING

SAND

JACK ASSEMBLY

PIT

CHANNELS

(2) HIGH-POTENTIAL

MAGNESIUM ANODE

RIBBON, SEE DETAIL

CONDUIT TO CP

JUNCTION BOX

#12 AWG XHHW

STRUCTURE LEADS

PIN-BRAZED TO JACK

ASSEMBLY

10/30/24

L. PEDERSON

E. JOHNSON

L. PEDERSON/E. JOHNSON B-D LINES

IN CHARGE

CHECKED BY

SCALE

DRAWN BY

DESIGNED BY

S. SINGH

DATE:

THE PREPARATION OF THIS

DRAWING HAS BEEN FINANCED IN

PART THROUGH A GRANT FROM

THE U.S. DEPARTMENT OF

TRANSPORTATION, FEDERAL TRANSIT

ADMINISTRATION (FTA), UNDER THE

FEDERAL TRANSIT ACT OF 1964, AS

AMENDED, AND IN PART BY THE

TAXES OF THE CITIZENS OF

LOS ANGELES COUNTY AND OF

THE STATE OF CALIFORNIA.

SHEET NO

REV DATE BY APP REG NO. EXPIRES SEAL HOLDER DESCRIPTION

CORROSION CONTROL

DRAWING NO

CONTRACT NO

REV

601 S. FIGUEROA ST. SUITE 3800

LOS ANGELES, CA 90017

PS46172000

AS INDICATED

LOS ANGELES COUNTY

METROPOLITAN TRANSPORTATION AUTHORITY

23309 LA PALMA AVE YORBA LINDA, CA 92887

CATHODIC PROTECTION DETAILS III

IC

EPSNOITCETORPCI

OHTAC

ECA N

N A C E I N T E R N AT I O

HGNISJVRAS

No. 6125

D

TS

IL

A

TI

N AL

CP-18

CP-19

EQUIPMENT SCHEDULE

SCALE: NOT TO SCALE

10/30/24

L. PEDERSON

E. JOHNSON

L. PEDERSON/E. JOHNSON B-D LINES

IN CHARGE

CHECKED BY

SCALE

DRAWN BY

DESIGNED BY

S. SINGH

DATE:

THE PREPARATION OF THIS

DRAWING HAS BEEN FINANCED IN

PART THROUGH A GRANT FROM

THE U.S. DEPARTMENT OF

TRANSPORTATION, FEDERAL TRANSIT

ADMINISTRATION (FTA), UNDER THE

FEDERAL TRANSIT ACT OF 1964, AS

AMENDED, AND IN PART BY THE

TAXES OF THE CITIZENS OF

LOS ANGELES COUNTY AND OF

THE STATE OF CALIFORNIA.

SHEET NO

REV DATE BY APP REG NO. EXPIRES SEAL HOLDER DESCRIPTION

CORROSION CONTROL

DRAWING NO

CONTRACT NO

REV

601 S. FIGUEROA ST. SUITE 3800

LOS ANGELES, CA 90017

PS46172000

AS INDICATED

LOS ANGELES COUNTY

METROPOLITAN TRANSPORTATION AUTHORITY

23309 LA PALMA AVE YORBA LINDA, CA 92887

EQUIPMENT SCHEDULE I

IC

EPSNOITCETORPCI

OHTAC

ECA N

N A C E I N T E R N AT I O

HGNISJVRAS

No. 6125

D

TS

IL

A

TI

N AL

CP-19

CP-20

EQUIPMENT SCHEDULE

SCALE: NOT TO SCALE

10/30/24

L. PEDERSON

E. JOHNSON

L. PEDERSON/E. JOHNSON B-D LINES

IN CHARGE

CHECKED BY

SCALE

DRAWN BY

DESIGNED BY

S. SINGH

DATE:

THE PREPARATION OF THIS

DRAWING HAS BEEN FINANCED IN

PART THROUGH A GRANT FROM

THE U.S. DEPARTMENT OF

TRANSPORTATION, FEDERAL TRANSIT

ADMINISTRATION (FTA), UNDER THE

FEDERAL TRANSIT ACT OF 1964, AS

AMENDED, AND IN PART BY THE

TAXES OF THE CITIZENS OF

LOS ANGELES COUNTY AND OF

THE STATE OF CALIFORNIA.

SHEET NO

REV DATE BY APP REG NO. EXPIRES SEAL HOLDER DESCRIPTION

CORROSION CONTROL

DRAWING NO

CONTRACT NO

REV

601 S. FIGUEROA ST. SUITE 3800

LOS ANGELES, CA 90017

PS46172000

AS INDICATED

LOS ANGELES COUNTY

METROPOLITAN TRANSPORTATION AUTHORITY

23309 LA PALMA AVE YORBA LINDA, CA 92887

EQUIPMENT SCHEDULE II

IC

EPSNOITCETORPCI

OHTAC

ECA N

N A C E I N T E R N AT I O

HGNISJVRAS

No. 6125

D

TS

IL

A

TI

N AL

CP-20

File details come from the government source that posted it. Updated .